Proposed Tech Specs 4.7.1.2.1.b.1 & 4.7.1.2.1.b.2,clarifying SR for Verifying Correct Required Position for Valves in Afs
ML20080C774
Person / Time
Site: Wolf Creek Wolf Creek Nuclear Operating Corporation icon.png
Issue date: 12/12/1994
From:
WOLF CREEK NUCLEAR OPERATING CORP.
To:
Shared Package
ML20080C772 List:
References
NUDOCS 9412200141
Download: ML20080C774 (2)


Text

..

.i.

y n: 9:_

'. x3 %

.AttachmehtlIV to CO 94-0032 s

.Page 1 of 2 s

j i:

ATTACHMENT IV PROPOSED TECHNICAL SPECIFICATION CHANGES i

9412200141 941212 PDR ADOCK 05000402 P

PDR J

y p

i e,

~

l?

, - Q' _

\\

[..-r' j

l Attachmeht IV to COl94-0032

,f

LPage 2 of 2 j

' I, I

.El,6MT SYSTEMS

' SURVEILLANCE REQUIREMENTS (Continued)

b. At least once per 31 days by:

, xce ithe a xilia feedwater pump discharge control valves,

1) Verifying that each non owtomake valve, in flow path a is not locked, sealed, or otherwise secured in position is in I.

Its correct position; and 1

l ump discharge control valve j

2) Verifying that each 21.:

. : ;;.;; in'the flow path isTn the j

fully ope ition whenever the auxiliary Feedwater System is j

placed in

t:nf: x....:: or when above 10% RATED THERMAL 1

POWER.

c. At least once per 18 months during shutdown by:
1) Verifying that each automatic valve in the ESW supply to the auxiliary feedwater pumps actuates to its full open position upon receipt of an Auxiliary Feedwater Pump Suction Pressure-Low test signal
2) Verifying that each auxiliary feedwater pump starts as designed

{

automatically upon receipt of an Auxiliary Feedwater Actuation i

test signal, and -

3) Verifying that each auxiliary feedwater motor-operated discharge valve limits the flow to each steam generator from the motor-ririven pump to less than or equal to 320 gpm.

4 71.2.2 An auxiliary feedwater flow path shall be demonstrated OPERABLE following each COLD SHUTDOWN of greater than 30 days prior to entering MODE 2 by verifying normal flow to at least two steam generators from one auxiliary foodwater pump.