GPU Nuclear Corporation E-Nuclear
- rn:r 8" Forked River. New Jersey 08731-0388 609 971-4000 Wnter's Direct Dial Number:
C321-94-2103 November 28, 1994 l
U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555
Dear Sir:
Subject:
Oyster Creek Nuclear Genemting Station Docket No. 50-219 IE Bulletin No. 78-14 Commitment The subject bulletin concerned the deterioration of BUNA-N components in ASCO solenoid valves in BWR control rw! 3 cram systems. GPUN committed to expand the Oyster Creek Preventive Maintenance Program to include the inspection and replacement of the BUNA-N material in each valve on a periodic basis to assure that the components are not used in excess of (7) years.
The GE BWROG has collaborated with GE and ASCO to develop a replacement scam solenoid pilot valve (SSPV) with a longer life than the one currently in use. The BUNA-N elastomers in the existing SSPV's have been replaced with a VITON-A elastomer during our recent 15R outage to provide a more durable component. Accordingly, the service life of the new component is a minimum 15 years.
Therefore, since all BUNA-N components havc been replaced, our commitment made to you in 1979 has been completed.
If you should have any questions or require further information, please contact Mr. Terry Sensue, Oyster Creek Licensing Engineer at 609-971-4680.
Sincfyy(
{
s, f
p h m J.
arton -
ice P56sident and Director Oyster Creek JJB/TS/je ec:
Administrator, Region 1 Senior NRC Resident Inspector
/ l[
Oyster Creek NRC Project Engineer 9412060306 941128
{DM ADOCK 05000219 0G0083 PDR t#U Nuclear Corporanon is a subsidiay of Veneral Pubhc Utit'es Corporation