ML20079Q673
| ML20079Q673 | |
| Person / Time | |
|---|---|
| Site: | Farley |
| Issue date: | 03/02/1983 |
| From: | Held J ENERGY, INC. |
| To: | Alberthal G Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML20079Q679 | List: |
| References | |
| RTR-NUREG-0737, RTR-NUREG-737, TASK-2.B.1, TASK-TM TAC-44371, TF-356-0812A, TF-356-812A, NUDOCS 8306070474 | |
| Download: ML20079Q673 (6) | |
Text
_-_
f~]
LAWRENCE LIVERMORE LABORATORY El i
ENCLOSURE 2 Selected Operating Reactor Issues Program II Reactor Coolant System Vents (NUREG-00737, Item II.B.l. )
NRC FIN A0250 - Project 9 FINAL TECHNICAL EVALUATION REPORT FOR FARLEY l AND 2 Docket Numbers 50-348 and 50-364 NRC TAC Numbers 44371 and 44372 Prepared by J. T. Held of Energy Incorporated - Seattle (Subcontract 4324401) for Lawrence Livermore National Laboratory under contract to the NPC Office of Nuclear Reactor Regulation, Division of Licensing.
NRC Lead Engineer - Gus Alberthal NOTICE "This report was prepared as an account of work sponsored by the United States Government. Neither the United States nor the United States Department of Energy, nor any of their employees, nor any of their contractors, subcontractors, or their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any information, apparatus, product or process disclosed, or represents that its use would not infringe privately-owned rights."
TF-356/0812a XA Copy Has Been:SenUoRR g pg7/47M March 2, 1983
. ~ '
universirrorca.icrn,a aosg tv ermo e.casruma s:ssu o reiesone.::s :.tr noa o :... sic ass esss ucat tyr..n r
Docket Numbers 50-348 and 50-364
. TAC Numbers 44371 and 44372 TECHNICAL EVALUATION REPORT ON REACTOR COOLANT SYSTEM VENTS FOR FARLEY l AND 2 INTRODUCTION The requirements for reactor coolant system high point vents are stated in paragraph (cX3Xiii) of 10 CFR 50.44, "Stnndards for Combustible Gas Control System in Light Water Cooled Power Reactors," ond are further described in Standard Review Plan (SRP)
Section 5.4.12, "Reoctor Coolant System High Point Vents," and item 11. 8. 1 of NUREG-0737,"Clorification of TMI Action Plan Requirements." In response to these and previous requirements, the Alabama Power Company has submitted information in References I through 4 in support of the vent system at Units I and 2 of the Joseph M.
Forley Nuclear Plant.
EVALUATION The function of the high point vent system is to vent noncondensible gases from the high points of the reactor coolont system (RCS) to assure that core cooling during natural circulation will not be-inhibited. The Farley I and 2 reactor vessel head vent system (RVHVS) provides venting capability from the reactor vessel head while the pressurizer con be vented through the existing powe. operated relief volves (PORVs).
The noncondensible gases, steam, and/or liquids vented from the reactor vessel head are piped and discharged above the reactor toward the reactor cavity walls, and the discharges from the pressurizer are piped to the pressurizer relief tank (PRT). The RVHVS is designed to vent a volume of hydrogen approximately equal to one half of the RCS' volume in one hour. Flow restriction orifices in the RVHVS paths,- however, limit -
the flow from o pipe rupture or from inodvertent octuation of the vent system to less than the capability of the reoctor-coo!ani makeup system.
Hence, the licensee's comptionce with 10 CFR 50.46, " Acceptance Criteria for Emergency Core Cooling Systems for Light Water Nuclear Power Reactors," is not offected by the addition of the RVHVS.
13/TER-P-8 Enclosure Page _i of 5
j The RVHVS consists of two vent paths from the reactor vessel head to the reactor cavity, each containing two solenoid-operated valves in series which are controlled from the main control room. Positive indication of volve position is also provided by way of position switches located on the valve stems and by monitoring status lights in the main control room. A degree of redundoney has been provided by powering each RVHVS vent p_oth from c separate emergency bus, to ensure that RCS venting capability from the reactor vessel head is maintained. RVHVS isolation volve seat leokoge con be detected by the existing reoctor coolant leakage detection system. The existing PORVs, used to vent the pressurizer to the PRT, con be monvally controlled from the main control room. The PORVs and block valves receive power from independent cmergency buses and have positive valve position indication in the main control room by way of valve stem limit switches. PORV seat leakage con be detected by temperature instrumentation on the PORV discharge lines and temperature, pressure, and level indication for the PRT.
The portion of each RVHVS path up to and including the second normally closed volve forms a part of the reactor coolant pressure boundary and thus must meet reactor coolont pressure boundary requirements. The licensee has stated that this portion of the RVHVS is designated Sofety Class 2 (Safety Class I upstream of the flow restriction orifices) in compliance with 10 CFR 50.55o and Regulatory Guide 1.26. The licensee has also stated that this portion of the RVHVS has been designed and fabricated in accordance with the seismic loading requirements of Section 111 of the ASME Boiler and Pressure Vessel Code for Class I and 2 systems, but the licensee has not verified that this portion of the RVHVS has been designated Seismic Category I in accordance with Regulatory Guide 1.29. Confirmation by the licensee that this portion of the RVHVS will be classified as Seismic Category I is required. The RVHVS is designed for pressures and temperatures corresoonding to the RCS design pressure and temperature. In addition, the vent system materials are compatible with the reactor coolant chemistry and are fabricoted and tested in occordance with SRP Section 5.2.3, " Reactor Coolant Pressure Boundary Materials."
The RVHVS and the pressurizer PORV vent system are also acceptably separated and protected from missiles and the dynamic effects of postulated piping ruptures. We therefore conclude that the design of the portions of the RVHVS up to and including the second normally closed valve conforms to all reactor coolant i
pressure boundary requirements, including 10 CFR 50.55o and the applicable portions o' General Design Criterio I, 2,4,14, 30, and 31, contingent on confirmation of acceptable seismic classification of this portion of the RVHVS. The licensee has further ascertained that the essential operntion of other safety-related systems will not be impaired by postulated failures of RVHVS components.
i3/TER-P 9 Enclosure Page 2 of 5
I We have reviewed the licensee's RVHVS design to assure on occer4 ably low probability exists for inadvertent or irreversible octuation of the vent system. Eoch vent path has two normally closed, foil closed volves in series, and each volve has on individual control switch and positive volve position indication by way of status lights in the main control room. Power for each RVHVS path is supplied by on independent emergency power train. The licensee has also stated that the controls and displays added to the main control room for the RVHVS will be considered in the long-term human factors analysis to reduce the potential for operator error. However, the Ferley I and 2 RVHVS design includes Target Rock solenoid-operated volves which may be susceptible t6 common mode failure because operation of one volve may cause other volves in the system to open temporarily (see Reference 5).
The licensee will be required to evaluate this problem and present their. conclusions including any design changes necessary to minimize the probability of inodvertent vent system actuation. Therefore, we find that no single octive component failure or human error should result in inadvertent opening or irreversible operation (i.e., failure to close offer intentional opening) of the RVHVS, contingent on a satisfactory resolution of the problem with Target-Rock solenoid-operated volves.
We have also examined the locations where the RVHVS normally discharges to the containment atmosphere in the vicinity of the reactor cavity and where the pressurizer vent system discharges via the PRT rupture disc. Based on a description by the licensee (Reference 1) these locations are in areas that assure good mixing with the containment atmosphere to prevent the occumulation or pocketing of high concentrations of hydrogen in compliance with 10 CFR 50.44, " Standards for Combustible Gas Control System in Light Water Cooled Power Reactors." Additionally, these locations are such that the operation of safety-related systems would not be adversely offected by the discharge of the anticipated mixtures of steam, liquids, and noncondensible gases.
The RVHVS is designed such that operability testing can be performed in occordonce with the requirements of subsection IWV of Section XI of the ASME Code for Category B volves.
The licensee hos also stated that operob;11ty te' sting of the PORVs is accomplished in occordonce with current plant technical specifications. However, the licensee must verify that the RVHVS volves will not be exercised every three months.
This is a confirmatory item.
i3/TER-P-8 Enclosure Page 3 of 5
CONCLUSION We conclude that the design of the Farley I and 2 RCS vent system, which includes the RVHVS and pressurizer PORV vent system, is sufficient to effectively vent noncondensible gases from the reactor coolont system without leading to on unocceptable increase in the probabilitty of a LOCA or a challenge to containment integrity, meets the design requirements of NUREG-0737 Item II.B.I and the applicable portions of General Design Criterio I, 2, 4, 14, 30, and 31, and conforms to the requirements of paragraph (cX3Xiii) of 10 CFR S0.44 We therefore recommend that the Forley I and 2 RCS vent system design be found acceptable with the following three confirmatory items. First, the licensee must verify that the portion of the RVHVS that is a port of the reoctor coolont pressure boundary will be classified Seismic Category I.
Second, the Torget Rock solenoid-operated volve problem noted above must be satisfoetorily resolved. Third, the licensee must verify that the RCS vent system volves will be exercised during each refueling outoge and not every three months. In addition, it should be noted that the following items were excluded from the scope of our review: seismic and environmental qualification of the RVHVS, RCS vent system operating guidelines and procedures, and required modifications to the plant technical specifications and in-service inspection program for the RVHVS.
l l
33/TER-P-8 Enclosure Page 4 of S
o i
REFERENCES 1.
Letter, F.L. Clayton, Jr. (Alabama Power Company) to A. Schwencer (NRC), with l
enclosure,"TMI Related Ovestion on Section ll.B.1, Reactor Coolant System Vents,"
dated September 22,1980.
2.
Letter, F.L. Cloyton, Jr. (Alabama Power Company) to S.A. Vorgo (NRC), "Forley Nuclear Plant Units I and 2, NUREG-0737 Response," dated January 14,1981.
3.
Letter, F.L. Clayton, Jr. (Alabama Power Company) to B.J. Youngblood (NRC),
" Joseph M. Forley Nuclear Plant - Unit 2, NPF-8 License Condition 2.c.(21Xb),"
dated June 25, 1981.
4.
Letter, F.L. Clayton, Jr. (Alabama Power Company) to S.A. Vorgo (NRC), _" Joseph M. Farley Nuclear Plant - Units I & 2, NUREC-0737, item II.B.I, Information Request for Reactor Coolont System Vents," dated April 30,1982.
5.
NRC Memorandum, T.P. Speis (Division of Systems Integration) to T.M. Novak i
(Division of Licensing), " Unintentional Lifting of Solenoid Operated Pilot Volves in i
RCS Vent System," dated March 9,1982.
i3/TER-P-8 Enclosure Page S of S
-.