ML20079P890

From kanterella
Jump to navigation Jump to search
Forwards Addl Fees Associated W/Tech Spec Change Request 69 to Allow Repair of Degraded Steam Generator Tubes by Sleeving
ML20079P890
Person / Time
Site: Point Beach  
Issue date: 05/04/1983
From: Burstein S
WISCONSIN ELECTRIC POWER CO.
To: Harold Denton, Diggs R
NRC OFFICE OF ADMINISTRATION (ADM), Office of Nuclear Reactor Regulation
References
NUDOCS 8305110201
Download: ML20079P890 (1)


Text

e O

l ca M

n@sconsin Electnc eom cown 231 W. MICHIGAN, P.O. BOX 2046. MILWAUKEE, WI 53201 gM

$)

{d k

May 4, 1983

'17 g [Id _. Q ce V $

,p

/('

CERTIFIED MAIL gg

^lf e

, A Ga 3

/

[r /

ky, #: I Mr.

H.

R.

Denton, Director Office of Nuclear Reactor Regulation g

co U.

S.

NUCLEAR REGULATORY COMMISSION Washington, D.

C.

20555 Attention:

Ms.

R. M.

Diggs Facilities Program Coordinator Office of Administration

Dear Mr. Denton and Ms. Diggs:

DOCKET NOS. 50-266 AND 50-301 AMENDMENT APPROVAL FEES TECHNICAL SPECIFICATION CHANGE REQUEST NO. 69 POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 In a letter dated April 20, 1983, the Nuclear Regulatory Commission has requested that Wisconsin Electric Power Company remit the additional sum of $8,300 as payment of the license amendment review and approval fees for the recently approved Tech-nical Specification changes which allow repair of degraded steam generator tubes by sleeving.

A Class IV fee was determined to be appropriate by your staff because this review involved consideration of several safety issues and issuance of an Environmental Impact Appraisal.

Accordingly, as requested, we have enclosed herewith a check drawn in the amount of $8,300 as payment of these additional fees.

Very truly yours, D

n

= ---

Exec tive Vice President Sol Burstein Enclosure (Check No. 728816) 8 Copy to NRC Resident Inspector 93 00

,,/ Lach :

0 O0 F (30 1

8305110201 830504 PDR ADOCK 05000266 P

PDR