._

es s

g xM k

ys M

Power C O R P O R A i s o se

- February 21,1983 3F-0283-23 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Subject:

Crystal River Unit 3 Docket No. 50-302 Operating License No. DPR-72 Environmental Reports

Dear Mr. Denton:

Pursuant to Crystal River Unit 3 Technical Specifications, Appendix B - Part II, Section 3.2, attached is a copy of the order changing NPDES Permit FL0000159 and the resulting Florida Power Corporation (FPC) notice to the Environmental Protection Agency (EPA) of our violation of the modified permit. A show cause order concerning this violation was issued by the EPA, and FPC is preparing a response.

Should you have any further questions concerning this matter, please contact this office.

Sincerely,

-, //

G. R. Westafer Manager Nuclear Licensing and Fuel Management Attachment DVH:mm cc:

Mr. J. P. O'Reilly, Regional Administrator Office of Inspection & Enforcement U.S. Nuclear Regulatory Commission 101 Marietta Street N.W., Suite 3100 Atlanta, GA 30303 8302230502 830221 PDR ADOCK 05000302 0%

U PDR 4

General Office 320 Thirty-soortn street souin. P.O. Box 14042. St. Petersburg, Florida 33733 813-866-5151 v.

.v

,g-w

.-w-e.--e--

y-e+--T-------

W

FED E ror O i

!g i UNITED STATES ENVIRONMENTAL PROTECTION AGENCY

%,,,oM REGION IV 345 CoURTLAND STREET DEC 2 8 }Q82 A,,7[%

ATLANTA. G EoRGIA 3 03 6 5 e

2 DISTRIBUTION

[!

3, q

'f b

B. L. Griffin CERTIFIED MAIL RETURN RECEIPT REQUESTED

s C

N. B. Spake

// g 4

J. A. Hancock H. A. Evertz

-h..v fgk y REF:

4WM-FP s

i k

r,3<c'-Q)g M. B. Foley, Jr.

'D

,k W. S. O'Brien R. W. Schooley Mr.

G.

C.

Moore i

(.,c '

Vice President Power Production Florida Power Corporation P.

O.

Box 14042 St. Petersburg, Florida 33733 RE:

Florida Power Corporation Crystal River Plant, Units 1-3 Citrus County, Florida NPDES Permit FL0000159

Dear Mr. Moore:

Pursuant to Section 309(a) of the Clean Water Act, the Director, Water Management Division, Region IV, United States Environmental Protection Agency (EPA), has determined chat the above-named facility is in violation of its NPDES permit.

As a result, the Director has issued a Section 309 Order

]

which is enclosed.

Any person who violates a Section 309 Order shall be subject to a civil penalty not to exceed $10,000 per day of such violation pursuant to Section 309(d) of the Clean Water Act.

If you have any questions concerning the enclosed Order, please contact Peter T.

McGarry, Chief, Florida-Mississippi Unit.

Industrial Operations Section, Water Managment Division at 404/881-7428.

I i

Sincerely yours, f

.e-ohn T.

Marlar Chief, Facilities Performance Branch Water Management Division I

Enclosure cc:

Mrs. Victoria J.

Tschinkel, FDER

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION IV IN THE MATTER OF Florida Power Corporation)

Crystal River Plant

)

NPDES PERMIT NO.

FLOOOO159

)

ORDER NO.

83-17(wCAB)

ORDER PURSUANT TO SECTION 309 FEDERAL WATER POLLUTION CONTROL ACT Pursuant to the authority of Section 309(a) of the Federal-4 I

Water Pollution Control Act (33 U.S.C. ((1251 and 1319(a))

which has been delegated to me, I hereby make the following findings of fact and violations and order:

I -

FINDINGS OF FACT 1.

Florida Power Corporation (hereinafter, the Permittee) has an electrical generating facility which discharges pollutants into waters of the United States.

2.

The United States Environmental Protection Agency, Region IV (EPA), has issued a National Pollutant Discharge Elimination System (NPDES) permit authorizing the above discharge from the facility by said Permittee.

3.

The present NPDES permit expired February 28, 1980, but Permittee filed application on August 30, 1979 for re-issuance of the permit with an additional ash pond and low volume waste discharges; therefore, pursuant t( 40 C.F.R.

122.5, the expired permit has continued in full force and effect.

4.

Permittee has in September 1979, May 1980, December 1980 and January 1981, exceeded its effluent limitation for Total Suspended Solids (TSS) at discharge serial number (DSN) 004 (ash pond).

5.

In order to alleviate the TSS problem at the DSN 004 ash pond, the pe rmi tte e has proposed reactivation of an existing but currently non-discharging ash pond which would be used alternately with the DSN 004 ash pond to allow periodic maintenance on the off-line pond.

=-wg-e---

y-

--v4---4 m-

,,w

. 6.

The proposed addi tional ash pond would provide storage capacity for 377,800 cubic yards of ash.

An additional ash pond is proposed because the DSN 004 ash pond has not been able to effectively treat ash sluice wastewater from both coal burning uni ts 1 &

2.

The increased rate of deposition of ash in the DSN 004 ash pond has exceeded the rate at which it is being removed and has resulted in a reduction in the effective pond size, retention time, and settling efficiency.

Since the total volume of waste water routed to the two ponds cumulatively is not proposed to exceed that now routed to the DSN 004 ash pond, the additional storage volume should substantially increase treatment efficiency applied to this waste stream.

No additional wastewater to that currently routed to DSN 004 ash pond is proposed to be added to the waste' streams for the two ponds now proposed.

7.

Permittee has requested authority to discharge from the ash pond proposed for reactivation.

Permit reissuance has not yet been completed.

8.

The location of the proposed discharge is nearly directly opposite DSN 004 ash pond across the receiving stream.

9.

The permit prohibits the discharge of low volume wastes to waters of the United States.

10.

Internal discharges (Outfalls 003 and 007) direct low volume wastes to Outfall 006.

VIOLATION 1.

The permittee has violated t h'e terms and conditions l

of the permit by discharging low volume waste through l

discharge point 006.

l l

2.

The permittee has violated the terms and conditions of the permit by discharging in September 1979, May 1980, December 1980, and January 1981 through DSN 004 Total Suspended l

Solids in concentrations exceeding the effluent limi ta tions l

in the permit.

I ORDER l

Based on the foregoing findings of fact and violation, and pursuant to the provisions of Section 309 of the Clean Water Act, as amended (33 U.S.C.

1319) it is hereby ordered that:

, 1.

Upon receipt of this Order and lasting until the facility is authorized by an NPDES permit to discharge from outfalls 003, 006, 007, and 009, you are ordered to comply with the attached effluent limitations and monitoring requirements for the specified outfalls with limitation requirements for outfall 006 becoming effective April 1,

1983.

Construction of the treatment system for wastes from outfall 0 0.*,

shall be complete by March 31, 1983.

2.

Parmittee may reactivate an exis ting but currently non-discharging ash pond (DSN 009) which shall be used alternately with the DSN 004 ash pond to avoid TSS violations.

3.

Permittee shall comply with all other terms and conditions of its present NPDES Permit.

4.

Monitoring results obtained during each calendar month shall be summarized on a Discharge Monitoring Report form (EPA form 3320-1).

Forms shall be submitted at the end of each calendar quarter and shall be postmarked no later than the 28th day of the month following the end of the quarter.

This monitoring shall begin on the first day of the month following the date of this order or in the case of outfall 009 the beginning date of the discharge.

5.

No portion of this order shall affect the emergency provisions contained in the permit.

6.

'This order shall expire and become null and void at the effective date of an NPDES permit.

7.

There shall be no point source discharge of the following categories of wastes to waters of the United States or to any waste stream which enters such waters except through DSN 003, 006, and 007 in accordance with the limitations indicated in the attachment to the Administrative Order: low volume wastes (including, but not limited to wet scrubber air pollution control systems, ion exchange water treatment systems, water treatment evaporator blowdown, laboratory and sampling streams, flow drainage, cooling tower basin cleaning wastes and blowdown from recirculating house service water systems), metal cleaning wastes (cleaning compounds, rinse waters, or any other waterborne residues derived from cleaning any metal process equipmert including, but not limited to, boiler tube cleaning, boiler fireside cleaning and air preheater cleaning and specifically including such water wash operations as hosing down boiler fireside surfaces), sanitary wastes, boiler blowdown and construction runoff.

Event recorders shall be placed at all overflow points from evaporation / seepage ponds receiving such wastes to assure compliance with this requirement.

r 8.

Permittee shall submit monitoring information required by this Order to the following addresses along with monitoring informatior required by present NPDES pe rm). t :

Chief, FL/MS Unit Industrial Operations Section Water Management Division United S ta tes Environmental Protection Agency 345 Courtland St.,

N.E.

Atlanta, Ga.

30365 Mrs. Victoria J.

Tschinkel Secretary Florida Department of Env. Regulation Twin Towers Office Building 2600 Blair Stone Road Tallahassee, Florida 32301

(~)

f

/ Is

-(

0 f f) tv '

i D $i Ya%

Date:

g

! Paul J.

Traina, Director Water Management Division l

2

,r.

n,.,,

ATTACllMENT During the period beginning on the effective date of this Order and lasting through expiration the Respondent is authorised to discharge from outfall(s) serial number (s) 003 1/ - Laundry and Shower Lump Tank (LSST) to OSN 006.

Such discharges shall be limited and monitored by the Respondent as specified belows Effluent Characteristic Discharge Limitations 3/

Monitoring Requirements kg/ batch (Ibs/ batch)2/

Other Unit 9 Measurement Sample (ag/l except as noted)

Frequency Type Daily Avg Daily Max Daily Avg Daily Max 3

Flow-m / Day (MGD)

N/A N/A 1/ batch calculation Oil and Grease 0.11(0.25) 0.15(0.33) 15 20 1/ batch Grab Total Suspended Solide 0.23(0.50) 0.76(1.67) 30 100 1/ batch Grab Nhenever metal cleaning wastes are discharged through this serial number, effluent shall not contain more than 8.345 lbs of total copper and total tron per million gallons'of metal cleaning waste generated and shall be monitered 1/ batch oy grab sample.

Notes The radioactive components of this discharge are regulated by the U.S. Nuclear Regulatory Commission under the Atomic Energy Act and are not regulated by the U.S.E.P.A. under the Clean Mater Act.

The pH shall not be less than 6.0 standard unite nor greater than 9.0 standard units and shall be monitored 1/ batch.

There shall be no discharge of floating solide or visible foas in other than trace amounts.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location (s): discharge from t,h e LSST treatment system prior to mixing with any other waste stream.

1/ Serial number assigned for identification and monitoring purposes.

2/ Daily average and daily maximum quantities discharged in kg/ day (1bs/ day) shall also be reported.

3/ Discharge limitations become effective April 1,

1983.

Monttoring requirements apply immedia tely.

ATTACINENT During the period beginning on the effective date of this Cedar and lasting through expiration the Respondent is authorised to discharge from outfall(s) serial number (s) 006 system discharge to the Plant Discharge Canal to the Gulf nf Mexico (includes OSN 003, 007, and the Evaporator Nuclear Services and decay heat seawater Condensate Storage Tank (ECRT) discharge).

Such discharges shall be limited and monitored by the Respondent as specified below Effluent Characteristic Discharge Limitations Monitoring Requirements Neasurement Sample Instataneous Frequency Type Daily Avg Daily Max Max 006 Flow-m3/ Day (NCD)

N/A ECST Flow - m3/ Day (NCD)

N/A Continuous Logs / Calc.

N/A N/A 1/ day Logs Total Residual Oxidants (ag/1)

Chlorine Addition (minutes / day)

N/A 60 1/ day Logs 0.4 1/ week Multiple Grab Total Suspended Solids (ag/LI N/A 30 011 and Grease (ag/1) 1/ week Grab N/A 15 1/ week Grab Nhenever metal cleaning wastes are discharged more than 8.345 lbs of total copper and through this serial number, effluent shall not contain total iron per million gallons of metal cleaning waste generated and shall be. monitored 1/ batch by grab sample.

Note: The radioactive components of this discharge are regulated by the U.S. Nuclear Regulatory Commission under the Atomic Energy Act and are not regulated by the U.S.E.P.A. under the Clean Mater Act.

There shall be no discharge of floating solide or visible foam in other than trace amounts.

Samples location (s):taken in compliance with the monitoring requirements specified above shall be taken at the following Total residual oxidants at point of discharge prior to entering plant discharge canals flow at the combined intake water pumps: and. flow, iron, copper, TSE, and oil and grease at the ECST discharge to OSN 006.

ATTACHMENT During the period beginning on the effective date le authorised to discharge from outfall(s) of this Order and lasting (SDT-1) to 08N 006 serial number (s) 007 1/ - Regenerationthrough empiration the Respondent Such discharges shall be Weste Neutralisation Tank limited and monitored by the Respondent

_ Effluent characteristic specified belows as

_ Discharge Limitations kg/ batch (1bs/ batch)

Other Unita Monitoring Requirementa 2/

Measurement (ag/l except as noted)

Daily Avg Daily Nam sample __

Frequency Flow-m3/ Day (NGO)

Daily Avg Daily Max Type oil and Grease N/A Total Suspended Solide 1.7(3.8) 2 3(5.0)

N/A 1/ batch 3.4(1.5) 15 11 4(25.0) 20 Calculation 30 1/ batch Whenever metal cleaning wastes 100 Grab 1/ batch are discharged through this serial number, effluent shall not Grab more than s.345 1he of total copper and total generated and shall be monitored 1/ batch by grab sample. tron per million gallons contain of metal cleaning waste Note: The radioactive componente of under the Atomic Energy Act and are notthis discharge are regulated by the U.S.

regulated by the U.S.E.p.A.

Nuclear Regulatory Commission The pN shall not be less 1/ batch.

then 6.0 standard unite under the Clean Water Act.

nor greater than 9.0 standard units and shall be monitored l

There shall be no discharge of floating solids or visible foam in other Samples location (s):taken in compliance with the monitoring than trace amounts.

discharge from the SDT-1 treatment system prior to mixing with other waste streams.th re q ui r ener. t o specified above shall be taken at tf serial number assigned Daily average.nd daily maximum quantities dischfor identification and monitoring purposes 2/

arged in kg/ day (1be/ day) shall also be reported.

O ATTACINENT During the period beginning on effective date of this Order and lasting through expiration the Respondent is authorised to discharge from outfall(s) serial number (s) 009 - Ash pond discharge (Units 1 and 2).

Such discharges shall be limited and monitored by the Respondent as specified below:

Effluent Characteristic Discharle Limitations Monitoring Requirements kg/ day (1bs/ day)

Other Units Measurement sample tag /l except as noted)

Prequency Type Daily Avg Daily Max Daily Avg Daily Max Flow - m3/ Day (MGD)

=

1/ week Grab 011 and Grease 260(560) 340(750) 15 20 1/ week Grab Total suspended solide 510(1130) 1700(3750) 30 100 1/ week Grab heavy Metals See Below See Below 1/ month Grab Limitations'are appl 1 cable to the combined discharges from both ash ponds, (004 and 009) although only one ash pond will be utilised normally. Discharges shall be from both ponds.

separately monitored during any periods of discharge Monitoring for heavy metals shall include total arsenic, cadmium, chromium, copper, iron, lead, mercury, nickel, selenium, and sinc.

Notes Limitations and monitoring requirements are not applicable during periods of no discharge.

The pH shall not be less than 6.0 standard unite nor greater than 9.0 standard units and shall be monitored s

1/ week.

There shall be no discharge of floating solide or visible foam in other than trace amounts.

Samples taken in compliance with the monitoring requirements specified above shall be taken at the following location (s): discharge from the ash pond prior to mixing with any other waste stream.

6 I

e e

6

bcc:

N. B. Spake-J. A. Hancock I

G. C. MooreQI '* h W y

H. A. Evertz, III D. A. Shantz R. E. Parnelle, Jr.

fCy w

/

h i

f,T%.

\\

D. \\

M CERTIFIED / RETURN RECEIPT REQUESTED $I syc[f y Q p

},7 yI l

- )l co"o="'o~

S Ac,Q'.f 4q "g:l/

6 1

January 21, 1983 c4 Mr. Peter T. McGarry 3TTT Chief, FL/MS-Unit

~

Industrial Operations Section Water Management Division l

Environmental Protection Agency 345 Courtland Street, N.E.

Atlanta, GA 30365 Re: Florida Power Corporation Crystal River Plant Order 83-17(wCAB)

Dear Mr. McGarry:

On January 10, 1983, the discharge from outfall 007, Regeneration Waste Neutralization Tank (SDT-1), exceeded the 20 mg/l daily maximum limit for oil and grease. The measured value was 50.9 mg/1.

A thorough assessment of this incident has taken place to determine the cause and develop means l

for avoiding this problem in the future.

It was concluded that no equip-i ment malfunction or operational action is attributable to the'high oil and grease discharge.

We suspect either a contaminated sample or analytical error.

As a matter of background, we have experienced several non-compliances via i

outfall 007 due to oil and grease since installation of the oil / water separation system in late 1981. -During 1982 we initiated numerous opera-tional and administrative actions in an attempt to eliminate the oil and grease problem. Our efforts met with some success as evidenced by only one high oil and grease dis.harge during the fourth quarter of 1982.

It is evident that to assure compliance during all operational conditions,

[

particulary startup and shutdown when very high wastewater flow occurs, additional system / equipment modifications may be necessary. We are inves-tigating both short and long term solutions' to this matter. When we meet with you in Atlanta concerning the Administrative Order, more specific l*

actions will be presented.

j We have also exceeded the 9.0 pH limit for this discharge as follows:

l 1/07/83 - 9.07 1/13/83 - 9.09 1/08/83 - 9.1 1/13/83 - 9.1 1/10/83 - 9.1 General Office 3201 in.rty-iourin street soutn. P O Box 14042. St Petersburg. Florida 33733 e 813-866-5151 i-

Mr. Peter T. McGarry January 21, 1983 Page 2 In various discussions prior to issuance of the subject order, the EPA had not expressed a concern with pH control. At present there is no mechanism for us te control the pH of this discharge. We are currently reviewing the options available and will be prepared to discuss this item at our Atlanta meeting, Sincerely, l

LSo%

William S. O'Brien Director Environmental & Licensing Affairs WSO/gr cc:

Mr. J. P. Subramani, FDER

_. _