ML20079H003

From kanterella
Jump to navigation Jump to search
Forwards Listed Sections of Tech Spec Upgrade Program, Per Request for Addl Info Re Application for Amend to Licenses DPR-29 & DPR-30
ML20079H003
Person / Time
Site: Quad Cities  Constellation icon.png
Issue date: 10/02/1991
From: Schrage J
COMMONWEALTH EDISON CO.
To: Murley T
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM), Office of Nuclear Reactor Regulation
Shared Package
ML20079H004 List:
References
NUDOCS 9110100071
Download: ML20079H003 (2)


Text

. _ - _ - _ _ _

,m ' C:mm:nw alth Edisin i 1400 Opus Place Q)) Down:rs Grovo, Illinois 60515 October 2,1991 Dr. Thomas E. Murley, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555 Attn: Document Control Desk

Subject:

Quad Cities Nuclear Power Station Units 1 and 2 Application for Amendment to Facility Operating Licenses DPR 29 and DPR 30, Appendix A. Technical Specifications Technical Specification Upgrade Program NELCLDackeLNosl0 25Aand10 2S5 Dr. Murley:

In 1990, Quad Cities Station initiated a formal program to enhance the Station's performance in various aspects of plant operation. The Performance Enhancement Program (PEP) was developed by assessing existing improvement olans, identifying potential weaknesses and prioritizing improvement actions.

Necessary improvements to the Technical Specifications were identified as one of the Station top priority issue. Details of the goal and methodology for the Technical Specification Upgrade Program are provided in the Executive Summary section of the proposed amendment. The Program has been previously discussed with n, embers of the NRR staff.

Pursuant to 10 CFR 50.90, Commonwealth Edison proposes to amend Appendix A, Technical Specifications to Facility Operating Licenses DPR-29 and DPR-30. The proposed amendment reflects Commonwealth Edison's efforts to upgrade existing Technical Specification Sections 3.5/4.5 " Core and Containment Cooling Systems",3.6/4.6 " Primary System Boundary" and 3.7/4.7 " Containment Systems". An overall description of the proposed amendment is also included in the Executive Summary.

The proposed amendment request for each Technical Specification section is provided as follows:

1. An Executive Summary of the Technical Specification Upgrade Program and the proposed amendment;
2. A summary of the changes;
3. A detailed description of the changes;
4. The proposed Technical Specification pages with the requested changes;
5. The existing Technical Specification pages for DPR 29. aie marked up to reflect the appropriate changes to the existing bases sections.
6. Commonwealth Edison's evaluation pursuant to 10 CFR 50.92(c) and 10 CFR 51.21; and.

The technical differences between the existing Unit 1 and Unit 2 Technical

~

Specifications.

h[ ,

911o10oo71 911002 g PDR ADOCK oSooo254 P PDR

Dr., Thomas E, Murley 2- October 2,1991 l

l The proposed amendment has been reviewed and approved by Commonwealth Edison's on-site and off-site review in accordance with Company procedures.

The Technic al Specification Upgrade Program proposes chanaes to each section of the existing Technical Specifications. As such, Commonwealth Edison requests that the proposed amendments be approved and issued as one document rather than as individual sections. Commonwealth Edison respectfully requests the NRC's approval of the upgraded Technical Specifications by July 1,1992.

To the best of my knowledge and belief, the statements contained are true and correct, in some respects, these statements are not based on my personal knowledge but obtained information furnished by other Commonwealth Edison employees and consultants. Such information has been reviewed in accordance with Company practice and I believe it to be reliable.

Commonwealth Edison is notifying the State of Illinois of this application for amendment by transmitting a copy of this letter and its attachments to the wesignated State Official.

Please direct any questions concerning this proposed amendment to J. Schrage at 708/515-7283. (

Very truly yours, .

/fl .- f Joha L. Schrage x = y' ~

Nucle'ar Licensing Administrator 3.5/4.5 " Core and Containment Cooling Systems" Enclosure (A):

(B): 3.6/4.6 " Primary System Boundary" (C): 3.7/4.7 " Containment Systems" cc: A.Bert Davis, Regional Administrator L.N. Olshan, Project Manager T.E. Taylor, Senior Resident inspector Illinois Department of Nuclear Safety State of if , County of ViI Signed before me on thise.s day p7y 7 ; ~ - ~

of. y ' 1991., f  ; y- -  ;;w

/ /, #, '

. ~-

~

.~d

~ ~^

Notary Public EM'f ~ ,

/964:0

. _ _ _ _ _ _ _ - _ - _ _ _ _ - - _ . _ _ _ _ _ _ _ _ _ _ _