_.. _ _ -. _ _.. _. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

.. f -)

CD&L Carolina Power & Light Company m y.

Brunswick Nuclear Project 91 JUN I8 P2 : N P.0, Box 10429 Southport, NC 28461-0429 June 13, 1991 i

FILE: - B09-13510A Mr. S.D. Ebneter, Administrator U.S. Nuclear Regulatory Commission Suite 2900

'101 Marietta Street, NW_

Atlanta, GA. 30323 BRUNSWICK STEAM ELECTRIC PLANT UNITS 1 & 2 DOCKET NOS. 50-324, 50-325

- LICENSE NOS.- DPT-62, DPR 71 INTEGRATED ACTION PLAN STATUS

Dear Mr. Ebneter:

Enclosed is our monthly status report on the Brunswick Integrated Action Plan.

Please give me a call if you have any questions concerning this report.

Very truly yours,

+

.R.B. Starkey, Jr., Vice President ldW Brunswick Nuclear Project 3

p MBK/bgo Enclosure cc:

BSEP Resident Office iMr. K.J. Ahern Mr. R.E. Carroll Mr. Lt. Loflin

. Mr. J.W. Spencer 9106260373 910613 l

PDR ADOCK 05000324 l

.qg O[-

w.m..s..m.p.t.t.,b. -

R Pos

'0

-2 000:

s CP&L Carolina Power & Light Company tr2 m M Er2E M EtILB MIm p N m E m2 Brunswick Nuclear Project June 13, 1991 MEMORANDUM TO:

Mr. R.A. Watson FROM:

R.B. Starkey, Jr.

SUBJECT:

Monthly Status Report Integrated Action Plan As of the end of April 1991,58 of 64 Level 1 Action items are reported as complete. Of the 291 Level 2 Action items, 278 (95.5 %) are complete.

One IAP Level 1 Action item was completed in April:

G1, Implement Actions to Resolve People issues, including Employee Suggestion System LAP Level 1 Action item D4, Develop Post-maintenance Testing for ASME Code Repairs, has been re-opened. An explanation is provided for this itern within the attached integrated Action Plan Status Report, independent reviews have been completed on 43 Level 1 Action items, and 13 more are in progress. A Schedule of Independent Assessments is a part of this report package.

Effectiveness reporting schedules have been estC lshed for LAP Action items wh we are reporting as completed.

l4

.N

-9 p) l4' (r

MBK/bge Attachment cc:

Mr. H.R. Banks Mr. T.L. Kosmatin Mr. B.R. Poteat Mr. R.M. Barrett Mr. B.P. Leonard Mr. R.B. Richey Mr. J.M. Brown Mr. J.P. Leviner Mr. W.W. Simpson Ms. K.M. Core Mr. A.M. Lucas Mr. M.S. Staton Mr. C.R. Dietz Mr. LH. Martin Mr. J.G. Titrington Mr. M.R. Foss Mr. B.D. McFeaters Ms. M.S. Timberlake Mr. M.D. Hill Ms. P.D. Morris Mr. G.E. Vaughn Mr. J.R. Holder Mr. J.W. Moyer Mr. R.L. Warden l

Mr. M.A. Jones Mr. R.C. Phillips Ms. S.V. Williams up.kmc\\a.bapstat. raw

BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET l

IAP NO.

ACTION ITEM MANAGER DATE DATE COMMENTS i

Al COhth1UNICATION STRATEGY FOR Starkey 12/31/90 Complete An Independent Review has been GOALS, PRIORITIES, EXPECTATIONS BNP completed by Audit Services. This Action Item has been closed by the NRC, Report 90-37. dated I

10/18/90.

4 i

A2 Ih1 PROVE EXTERNAL RELATIONSIIIPS Watson 01/31/90 Complete An Independent Review has been I

NGG completed by Corporate QA.

Bl th1PLEh1ENT TECIINICAL SUPPORT IIelme 09/30/90 Complete An Independent Review has been Ih1PROVEh1ENTS Tech Support completed by Audit Services. This Action item has been closed by the NRC, Report 90-16, dated 05/02/90.

3 B2 th1PLEh1ENT NED ORGANIZATIONAL Brown 06/30/90 Complete An Independent Review has been th1PROVEh1ENTS NED completed by hianagement Services.

The NRC considers this Action Item

" ope n."

B3 Ih1PLEh1ENT NUCLEAR TRAINING Leonard 06/30/90 Complete An Independent Review is in ORGANIZATIONAL Ih1PROVEh1ENTS BTU progress by hianagement Services.

This Action item has been closed by the NRC, Report 90-39, dated 10/05/90.

4 B4 lh1PLEh1ENT CONTROL &

Simpson 12/31/89 Complete An Independent Review is in ADh11NISTRATION ORGANIZATIONAL C&A progress by hianagement Services.

Ih1PROVEh1ENTS

  • Indicates change from last month's report.

IAPS3 1

BRUNSWICK' NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,'1991 ORIGINAL TARGET IAP NO.

ACTION ITEM MANAGER DATE DATE COMMENTS B5 IMPLEMENT NUCLEAR PLANT SUPPORT 11111 06/30/90 Complete An Independent Review has been ORGANIZATIONAL IMPROVEMENTS NPS

ompleted by Management Services.

B6 IMPLEMENT OUTAGE MANAGEMENT &

lloider '

12/31/89 Complete An Independent Review has been MODIFICATIONS ORG ANIZATIONAL OM&M completed by Audit Services. The IMPROVEMENTS NRC considers this Action Item "open."

B7 Construct Permanent Office Building Johnson 10/31/93 03/30/93 Combined design / build reflects an OM&M earlier completion date. Date includes Phase 11: parking and paving.

a.

Develop a Brunswick Site Facilities Plan Broadway 09/30/90 Complete Mgmt. Sves b.

Provide project scope and funding to Simpson 09/30/90 Complete

'the Nuclear Engineering Department, to C&A begin site investigation and development of a request for bids.

c.

Complete site investigation and issue Johnson 03/31/91 05/20/91*

  • Site investigation complete as of requests for bids.

OM&M 04/15/91. Issuance of requests for bids delayed due to additional I

reviews.

l d.

Award bid for design / build contract.

Johnson 05/31/91 07/01/91*

Combined design and construction OM&M bids under one contract.

e.

Complete site preparation.

Johnson 05/31/92 05/31/92 OM&M

  • Indicates change from last month's report.

IAPS3 2

l

BRUNSWICK NUCLEAR PROJECT.

. INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACTION ITEM MANAGER DATE DATE COMMENTS f.

Complete construction and begin Johnson 10/31/93 12/31/92*

Reflects completion of building relocation of personnel.

OM&M only.

Cl IMPLEMENT CORPORATE NUCLEAR.

Wagoner 06/30/90 Complete An Independent Review has been PRIORITIZATION PROCESS OM&M completed by Management Services.

The NRC considers this Action Item i

"open."

C2 ESTABLISil NED BUDGET ITEM FOR Brown 12/31/89 Complete An Independent Review has been i

GENERIC WORK NED completed by Management Services.

C3 ESTABLISII BUDGET & RELEASE Wagoner 12/31/89 Complete

'An Independent Review has been PROCESS FOR NON-IPBS ENGINEERING OM&M completed by Management Services.

C4 DEVELOP LONG RANGE PLANNING Vaughn 12/31/90 Complete An Independent Review has been BUDGETS FOR EMERGING NSD completed by Management Services.

ISSUES / REGULATIONS D1 RESOLVE SURVEILLANCE TEST Starkey 03/31/90 Complete An Independent Review has been PROGRAM QUESTIONS BNP completed by Audit Services. The NRC considers this Action item "open."

D2.1 IMPROVE MANAGEMENT OF Warden 06/30/90 Complete An Independent Review has been MAINTENANCE BACKLOG Maintenance completed by Management Services.

This Action Item has been closed by the NRC, Report 91-07, dated 03/21/91.

  • Indicates change from last month's report.

IAPS3 3

BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACTION ITEM' MANAGER DATE DATE COMMENTS D2.2 STRENGTilEN MAINTENANCE Warden 06/30/90 Complete An Independent Review has been PLANNING FUNCTIONS Maintenance completed by Management Services.

This Action Item has been closed by the NRC, Report 91-07, dated -

[

03/21/91.

D3 FINE TUNE MOV MAINTENANCE Warden 06/30/90 Complete The NRC considers this Action Item I

l PROGRAM Maintenance

" ope n."

?

)

D4 Develop Post-Maintenance Testing for ASME lielme 10/15/89 To be

'Re-opened to allow additional time Code Repairs Tech Support determined to adequately evaluate the I

(Re-effectiveness of actions already in i

opened) place. An action plan will be

.f submitted within 30 days, detailing activities, and a new target date established. An Independent Review has been completed by BNP Site QA. The NRC considers this Action Item "open."

a.

Complete development of ENP-16.12 Helme 10/15/89 To be Tech Support determined b.

Complete development of PLP-08 IIelme 10/15/89 To be i

Tech Support determined I

t D5 Implement Recommendations of IIPCI IIelme 12/31/90 05/31/91 Need for a new Maintenance Reliability-Centered Maintenance Study Tech Support procedure has been identified, and i

is being prepared.

  • Indicates change from last month's report.

IAPS3 4

e

BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACflON ITEM httNAGER DATE DATE COMMENTS Review flPCI RCM and list IIelme 02/15/90 Complete

a..

recommendations, evaluate and Tech Support prioritize recommendations, categorize recommendations, perform cost / benefit analysis of recommendations, and perform potential problem analysis.

b.

Obtain management direction on Ifelme 03/31/90 Complete recommendations.

Tech Support c.

Implement changes requiring procedure IIelme 09/01/90 05/31/9:

Procedure revisions are complete. A new Maintenance procedure is revisions only.

Tech Support required which is now being developed.

d; Initiate PID's on items requiring Ifelme 07/01/90 Complete modifications, if any.

Tech Support e.

Obtain vendor concurrence on IIelme 09/01/90 Complete recommendations affecting vendor Tech Support recommendations.

f.

Initiate diesel generator RCM in fielme 10/31/90 Complete conjunction with CNS SSFI on diesel Tech Support generators, by performing actions in (a.)

above for diesels.

Present results to management of IIPCI IIelme 09/01/90 Complete l

g.

l work to date.

Tech Support LAPS 3

  • Indicates change from last month's report.

5 i

BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACTION ITEM MANAGER DATE DATE COMMENTS h.

Establish program to review impact of lielme 09/01/90 Complete llPCI RCM quarterly.

Tech Support i.

Assess value of RCM for RCIC and llelme 12/01/90 Complete other f.'fety systems.

Tech Support j.

Repeat actions of I 7CI RCM for diesel llelme 1I/01/90 Complete generators, starting with (b.) above.

Tech Support k.

Present results of RCIC and other safety IIelme 12/31/90 Complete systems' RCM review to management Tech Support with recommendations.

D6 ADDRESS SERVICE WATER SYSTEM Brown 11/30/90 Complete

  • An Independent Review is in DESIGN ISSUES NED progress by On-Site NAD. Thi>

Action item has been closed by the NRC. Report 91-01, dated 02/12/91.

D7 Confirm Design Basis for Key Brunswick Brown 12/31/91 12/31/93 The scope of this Action Item has been greatly increased. The NRC NED Systems considers this Action item "open."

IAPS3

  • Indicates change from last month's report.

6

~~

BRUNSWICK NUCLEAR PROJECT.

INTEGRATED ACTION PLAN STATUS:

April 30,1991 IAP NO.

ACTION ITEM ORIGINAL TARGET MANAGER DATE DATE COMMENTS Complete the United Engineers &

a.

Bishop 12/31/91 12/3!/93

  • The GE design basis document Constructors (UE&C) and General NED Electric System Desi s Criteria effort has 13 of 15 DBDs now E

Turnover Project.

working. The CP&L licensing file search is 100% complete.

Engineering historical file searches are 100% complete. Review and cataloging of UE&C Study Reports and calcelations is 100% complete; of plant modification calculations is i

70% complete; and of Engineering Evaluation Reports (EERs) is 25%

complete.

b.

Complete the UE&C Piping Design Langlois 12/31/91 05/31/92

  • Schedule completion is being Turnover Project.

NED monitored by large and small bore piping system milestone date charts.

Seismic analysis deferral from 12/91 to 05/92 was based on relative safety significance of remaining i

seismic work. liigh risk systems are scheduled first. PRA indicates higher priority associated with lectrical design. Industry e

valuation of earthquake data e

supports lower risk.

c.

Evaluate the results of the SW Brown modification review and SSFI findings 06/30/90 Complete NED and the llPCI and SLC SSFI results, and commitment date. Management is to identify and document any further necessary actions.

' Indicates change from last month's report.

LAPS 3 7

BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACTION ITEM MANAGER DATE DATE COMMENTS D8 COMPLETE UPDATE OF CORPORATE Brown 03/31/90 Complete An Independent Review has been completed by Audit Services. This AND SITE DESIGN PROCEDURES NED Action Item has been closed by the NRC, Report 90-16, dated 05/02/90.

D9 IMPLEMENT CORRECTIVE ACTION Spencer 04/30/90 Complete

' An Independent Review has been completed by NAD. The NRC PROGRAM IMPROVEMENTS BSEP considers this Action Item "open."

DIO DEVELOP AND INSTITUTIONALIZE Vaughn 12/31/90 Complete

'An Independent Review has been completed by NAD. The NRC CORPORATE CORRECTIVE ACTION NSD considers this Action item "open."

PROGRAM Dil DEVELOP CORPORATE PROGRAM FOR Crawford 02/15/90 Complete An Independent Review has been completed by BNP Site QA. The CONSISTENT PERFORM ANCE OF SAFETY CNS NRC considers this Action Item REVIEWS

" ope n."

D12 IMPROVE BUSINESS PLANNING PROCESS Simpson 06/30/90 Complete An Independent Review has been completed by Management Services.

C&A D13 REVIEW BNP PROCEDURES FOR Kesmodel 04/01/90 Complete An Independent Review has been completed by Audit Services. This COMPLIANCE WITIl PAM INTENT C&A Action Item has been closed by the NRC, Report 91-11, dated 04/16/91.

D14 IMPROVE CONSISTENCY OF Ifill 10/01/90 Complete An Independent Review is in progress by Management Services.

PROCUREMENT PROCESSES BY NPS NUCLEAR PLANTS IAPS3

' Indicates change from last month's report.

8

BRUNSWICK NUCLEAR PROJECT

~

~

INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACTION ITEM MANAGER DATE DATE COMMENTS D15 REQUIRE NUCLEAR SERVICES Vaughn 12/31/90 Complete An Independent Review has been DEPARTMFNT INVOLVEMENT IN NSD completed by Management Services.

REGULATORY DRIVEN MODIFICATIONS D16.1 INCIIEASE ROLE OF NUCLEAR PLANT Vaughn 12/31/90 Complete An Independent Review has been SUPPORT IN DEVELOPMENT OF NSD completed by Management Services.

CONSISTENCY AMONG NUCLEAR PLANTS D16.2 FORM ALIZE INITIATIVES TO Vaughn 12/31/90 Complete An Independent Review has been l

STANDARDIZE PROCESSES AND NSD completed by Management Services.

PROCEDURES

[

D17 INCREASE USE OF ISD'S DIRECTIVES Simpson 12/31/89 Complete An Independent Review has been AND RESOURCES C&A completed by Management Services.

D18 SUBMIT SIMULATOR CERTIFICATION Leonard 12/31/90 Complete

'An Independent Review has been BTU completed by On-Site NAD. The NRC considers this Action item

" ope n."

a.

Integrate and complete the test program Geise 03/01/90 Complete for the upgraded boiler / core models.

BTU b.

Complete test program required for Geise 09/01/90 Complete certification.

BTU c.

Complete document to support Geise 12/01/90 Complete certification.

BTU l.

' Indicates change from last month's report.

IAPS3 9

~

o

i 4

i CRUNSWICK NUCLEAR PROJECT l

l

!NTEGRATED ACTION PLAN STATUS: April 30,1991 l

[

l-DATE DATE COMMENTS l

ORIGINAL TARGET

(

{_

IAP NO.

' ACTION ITEM MANAGER t

i I

~

d.

Submit certification package to.

Geise 12/01/90 Complete

[

mar. age ent for review.

BTU l

1 i

e.

Submit package to NRC.

Geise 12/31/90 Co uplete

[

j i

BTU 8

1 1

D19.1 IMPLEMENTSYSTEM IOR RESPONDING Leonard 05/31/90 Complete An Independent Review is in l

TO TRAINING REQUESTS BTU progress by Management Services _

t D19.2 PROVIDE COORDINATED RESPONSE TO Leonard 05/31/90 Complete An Independent Review is in REGULATORY-RLLATED TRAINING BTU progress by Management Services.

[

REQUESTS

[

i-i i

D20 REVISE STANDING INSTRUCTIONS Mover 10/27/89 Complete An Independent Review has been j

PROCEDURE TO REQUIRE INDEX LOG Operations completed by Corporate QA. This Action Item has been closed by the NRC, Report 90-02. dated j

l 02/16/90.

l t

D21 REVIEW SWFCG CHARTER /GU' IDES FOR Peeler 07/31/90 Complete An Independent Review has been CURRENT GOALS, PRIORITIES OM&M completed by Manas;ement Services.

F This Action Item has been closed by I

the NRC, Report 90-42, dated

[

j 10/29/90.

l

?

t D22 IMPLEMENT TAGGING AND LABELING Warden 02/28/90 Complete An Independent Review ha, been h

i IMPROVEMENT PROGRAM Maintenance completed by Audit Services. This i

i Action item has been closed by the NRC, Report 90-39, dated j

10/05/90.

[

t i'

t

  • Indicates change from last month's report.

IAPS3 i

10 l

\\

,-n--.

-o

.--- -..-. -..-.-..I

CRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991

~

l; i

i ORIGINAL TARGET IAP NO.

ACTION ITE31 MANAGER DATE DATE CO3DIENTS l

i l

D23 Integrate Ph1 Vibration Program with Ash 1E Helme 12/31/90 10/31/91 The original intent of this Action j

Sec. XI IST Program Tech Support item was met by the original target date. However, a portion of this i

Action item has been merged with another ongoing program which is scheduled for completion in late 1991 a.

Approse and implement a Vibration Helme 12/31/89 Complete hionitoring Procedure.

Tech Support b-Ensure all equipment is marked.

Helme 02/28/90 Complete indicating points from which to take Tech Support readings.

c.

Purchase data collector instrumentation ilelme 02/28/90 Complete to be used to collect the vibration data.

Tech Support i

d.

Provide Real-Time Training to Helme 02/28/90 Complete Auxiliary Operators on operatien of Tech Support data collectors.

e.

Develop reference values and baselines Helme 05/31/90 09/30/91 to establish the initial points and Tech Support determine the

  • alert
  • and " required action" ranges.

j f.

After establishing mark points and 51 oyer 08/31/90 10/31/91 ranges, rettse pts accordingly.

Operations

  • Indicates change from last month's report.

IAPS3 11

BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACTION llEM MANAGER DATE DATE COMMENTS D24 IMPLEMENT BUDGETING OF SMALL -

Helme 12/31/90 Complete An Independent Review has been ENGINEERING PROJECTS Tech Support completed by Management Services.

This Action Item has been closed by the NRC, Report 90-23, dated 07/II/90.

D25 USE PROJECT MANAGEMENT Moore 07/31/89 Complete An Independent Review has been APPROACH IN PLANNING / EXECUTION OM&M completed by Audit Services.

OF OUTAGES D26 FORMALIZE PLANT WORK SCHEDULE Spercer 12/31/89 Complete An Independent Review has been ADHERENCE CONTROL BSEP completed by Management Services.

D27 IMPROVE TRACKING / DISPOSITION OF Helme 12/31/89 Complete An Independent Review has been TEMPORARY PEPAIRS/ CONDITIONS TO Tech Support completed bf BNP Site QA.

EXPEDITE ELIMINATION D28 REVISE EOP'S TO SIMPLIFY AND MATCH jMoyer 12/31/90 Complete

  • An Independent Review has been BWROG GUIDELINES Operations compteted b; NAD. This Action Item has been closed by the NRC.

Report 91-1I, dated 04/16/91.

D29 IMPLEMENT NGG GUIDELINE RE: -

Hill 06/30/90 Complete An Independent Review has been STRUCTURE OF CP&L ISI

. NPS completed by BNP Site QA. This PROGRAMS.AND ESTABLISHMENT OF 6-Action Item has beera closed by the j

MONTH INFORMATION EXCHANGES NRC, Report 90-32, dated i

10/I8/90.

D30 IMPLEMENT ACTIONS FOR 5% pson 06/30/90 Complete An Independent Review has been ADMINISTRATIVE COST CONTAINMENT C&A completed by Management Services.

' Indicates change from last month's report.

IAPS3 12 a

BRUNSWICK NUCLEAR PROJECT i-INTEGRATED ACTION PLAN STATUS: April 30,1591 ORIGINAL TARGET i.

IAP NO.

ACTION ITEM MANAGER DATE DATE COMMENTS i

D31 CONSOLIDATE, UPDATE, SIMPLIFY BNP Simpson 09/30/90 Complete An Independent Review has been PROCEDURES C&A completed by Audit Services. The j.

NRC considers this Action Item l

  • open.*

1 l

D32 IMPLEMENT BRUNSWICK NUCLEAR Moyer 01/15/91 Complete The NRC considers this Action Item PROJECT DEPARTMENT LICENSED Operations

  • open.*

i OPERATOR TRAINING IMPROVEMENTS 1

j D33 Implement Nuclear Services Department Leonard 03/29?M 08/31/91 The NRC considers this Action Item Licensed Operator Train.ing Improvements BTU "open*

i j

a.

Review the adequacy of training Leonard 07/31/90 Complete

  • Additional Closure documentation l

staffing levels, and identify near term BTU will be provided in May 1991.

needs.

1 l

L 4

I 4

i

  • Indicates change from last month's report.

IAPS3 i

13 1-

+

BRUNSWICK NUCLEAR PROJECT i

~

INTEGRATED ACTION PLAN STATUS: April 30,1991 1

i ORIGINAL TARGET h

IAP NO.

ACTION ITEM MANAGER DATE DATE COMMENTS I

(

J b.

Increase the number of simulator Leonard 09/30/90 05/31/91 TI-200 has been revised to require a i

training hours to a minimum of sixteen BTU-(re-opened) minimum of 64 simulator training hours per quarter per licensed operator, hours per licensed operator per year.

l and assess the impact of this change on meeting the original intent of D335

{

i '

the adequacy of training staffing levels.

By 05/31/91, TI-200 will be further i

l revised to require a minimum of 8 I

hours of simulator training per l

quarter, with 64 hours7.407407e-4 days <br />0.0178 hours <br />1.058201e-4 weeks <br />2.4352e-5 months <br /> remammg as 1

[

the annual minimum. (The

[

originally proposed 16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br /> per quarter may be unreasonable due to other training commitments and constraints.)

i i

c.

Revise the Licensed Operator -

Leonard 10/31/90 Complete

  • Additional Closure documentation Requalification Training Instruction to BTU will be provided in May 1991.

ensure operators receive adequate.

[

simtlator training time in alllicensed

[

I positions for which they may be examined.

c 1

I

[

1 t

I i

+

i i

l I

i-f 1

-(

  • Indicates change from last month's report.

IAPS3.

i; 14

[

t f

r

BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACTION ITEM MANAGER DATE DA'IE COMMENTS d.

Establish rigorous standards, Leonard 10/31/90 Complete

  • Additional Closure documentation l

performaace expectations, and monitor BTU will be provided in May 1991.

operator performance, via reports and personal invalvement, especially for the Moyer annual dynamic simulator evaluation.

Op-rations Periodically sample the results of simulator training to monitor operator performance. (Periodic monitoring and assistance in administering annual simulator examinations will be provided by Operations.) Place these l

requirements in the appropriate training instructions.

Revise the appropriate training Leonard 10/31/90 Complete e.

procedures to establish objective BTU simulator performance evaluation criteria for both Licensed Operator Requalification and flot License j

examinations, at least as stringent as the NRC test criteria.

f.

Incorporate installation of an Leonard 12/15/90 Complete

  • Additional Closure documentation uninterruptible power supply for the BTU provided t/10/90.

The installed system has performed simulator into the prioritized work satisfactorily during testing and planning process.

during an unplanned power outage to the simulator.

t IAPS3

  • Indicates change from last month's report.

15

BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACTION ITEM MANAGER DATE DATE COP

~ENTS Establish a remedial training program Leonard 12/15/90 Complete g.

which addresses the operators' BTU deficiencies, minimizes the disruption to Operations and Training work schedules, and provides rigorous feedback to enhance the operator training program.

h.

Review and establish long-term Leonard 12/31/90 Complete

  • Additional Closure documentation resource staffing needs and associated BTU will be provided in Stay 1991.

training str.if requirements.

i.

Revise the responsibilities of the Leonard 12/31/90 Complete existirg Trainiriy Advisory Committee BTU to inc!t.de a review, on a quarterly basis, of changes in operating philosophy, regulatory requirements, operator crew composition, et cetera (other than simulator charr,es), that might affect the training program.

J.

Improve the use of availr.ble Lconard 01/15/91 Complete Instructors have been trained by the information by establishing guidance to BTU Stanager - BTU, on effective methods for addressing operating assure that industry information is experience. TI-200. 3.9.4.3 also properly analyzed, disseminated, and addresses this issue.

used to improve performance.

IAPS3

' Indicates change from last month's report.

16

BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACTION ITE31 SIANAGER DATE DATE CO3131ENTS k.

Establish guidance for Brunswick Leonard 01/15/91 Complete Guidance has been provided by a Training Unit observation and BTU memorandum from the Manager, Nuclear Training Section.

participation in industry activities, and Procedure revision has been incorporate this guidance into Nuclear determined to be inappropriate for Training Section procedures.

this type of management issue.

1.

Enhance the process for the Leonard 01/15/91 Complete Process changes delayed to avoid identification and incorporation of BTU impact on simulator certification submittal needed changes to the simulator training process.

f m.

Establish procedural guidance which Leonard 01/15/91 Complete provides direction for ensuring that BTU simulator modifications are properly identified, and that appropriate training for these modifications is provided to licensed personnet Incorporate scheduling of training on Leonard 01/15/91 Complete Training on ECCS is incorporated in n.

Emergency Core Cooling System BTU TI-201 for ifot License classes. TI-200 addresses ECCS training as a malfunctions and interlocks into sa'ety system topic. Current liLC appropriate documents.

aid LOR attendees received training oa ECCS malfunctions and inteilocks within the past 9 months, as specified by these procectures.

' Indicates change from last month's report.

IAPS3 17

BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACTION ITEM MANAGER DATE DATE COMMENTS o.

Develop a self-assessment process that Leonard 01/15/91 Complete Criteria have been established by will be used to increase the BTU the Brunswick Training Unit to effectiveness of the tiaining program,.

conduct comprehensive self-based on test results at the conclusion of assessments. Instructors have been each flot License Class and each year's trained on methodology.

Licensed Operator Requalification, which will serve to identify weaknesses and changes needed it; the LOR and IILC programs.

p.

Conduct an independent evaluation, Leonard 01/31/91 Complete

  • This Action Item has been re-pricr to the 1990 examinations, using BTU opened. An independent evaluation personnel who are not directly of LOR was completed by a conducting training of the Licensed contracted evaluator in 10/90, but Operator Requalification examination the administrative requirement for readiness, and incorporate a independent evaluation was not requirement for the independent formalized by procedure.

j evaluations of the Licensed Operator Independent evaluations are Requalification and Hot License scheduled or underway for 1991 examination readiness into the llLC and LOR, and procedure 4

Brunswick Training Instructions.

revision will be completed by 04/30/91.

I l

l

  • Indicates change from last month's report.

IAPS3 I8

BRUNSWICK NUCLEAR PROJECT

[

~

INTEGRATED ACTION PLAN STATUS: April 30,1991 i,

ORIGINAL TARGET l

IAP NO.

ACTION ITEM MANAGER DATE DATE COMMENTS

(

q.

Develop a formal Simulator Scenario Leonard 02/28/91 Complete NTS Al-33," Development of i

Writers's Guide for all phases of the BTU Licensed Operator Requalification Licensed Operator Requalification Exam htaterial." was revised to examination, to include guidelines for incorporate guidance in this area.

[

. the development of more challenging

[

scenarios into the Licensed Operator i

Requalification examination, and to identify equipment and training aides to i

be used in simulator training scenarios, t

and to include direction in the periodic use of video and audio equipment to l

allow the operators to become

[

accustomed to them.

r.

Develop self-assessment criteria that Leonard 03/29/91 Complete See comment by *o

  • will be used to increase the BTU i

effectiveness of the training program, i

based on test results at the conclusion of j

each Hot License Class and each year's t

Licensed Operator Requalification, which will serve to identify weaknesses and changes needed in the LOR and l

HLC programs. Implement the criteria in the appropriate unit and section training procedures.

t i

s.

Implement scheduled improvements in Leonard 08/31/91 08/31/91 l

operator training program procedures.

BTU f

t

[

?

  • Indicates change from last month's report.

IAPS3 l

19 l

l 4

BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACTION ITEM MANAGER DATE DATE COMMENTS El DEFINE, TRACK OPERATIONAL AND Starkey 12/31/89 Complete An Independent Review has been MANAGEMENT PERFORMANCE; BNP completed by Audit Services. This i

DOCUMENT GOALS TO BE USED TO Action Item has been closed by the MANAGE PERFORMANCE NRC, Report 91-06, dated

)

04/12/91.

E2 ENSURE IMPROVEMENT PROGRAMS Starkey 09/30/90 Complete An Independent Review has been ARE IMPLEMENTED / MONITORED BNP completed by Management Services.

This Action item has been closed by the NRC, Report 91-66, dated 04/12/91.

E3 REVISE LOR l'ROGRAM, EMPHASIZING Leonard 01/31/90 Cornplete An Independent Review has been EFFECTIVE CONTROL ROOM LOG BTU completed by BNP Site QA.

ENTRIES l

E4.1 ISSUE INTEGRATED Banks 12/31/90 Complete An Independent Review is

(

AUDIT / SURVEILLANCE PLAN FOR BNP CQAD underway by Audit Services. The ENGINEERING NEC considers this Action item j

"open."

E4.2 DEVELOP CORPORATE QA C. W. Crawford 12/31/90 Complete

  • An Independent Review is PERFORM ANCE-BASED OVERVIEW NAD underway by Audit Services.

PLAN Reportability for this Action item has been transferred to Item E5.

The NRC considers this Action item "open."

E4.3 ADJUST AUDIT IMPROVEMENTS IN Banks 12/31/90 Complete An Independent Review has been PROGRESS TO ADDRESS DET CQAD completed by Audit Services. The CONCLUSIONS NRC considers this Action Item

  • open."

l 1

l

  • Indicates change from last month's report.

IAPS3

(.

20

i 1

l BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 ORIGINAL TARGET IAP NO.

ACTION ITE31 SIANAGER DATE DATE CO5151ENTS ANALYZE METHODS OF INDEPENDENT C. W. Crawford 12/31/89 Complete

'An 'ndependent Resiew is in progress by Audit Services. The E5 ASSESSMENTS FOR PERFORMANCE NAD NRC considt ts this Action item EVALUATION

'open.'

Select members for Project Quality Eury 10/31/89 Complete a.

Team to analyze nuclear evaluation and EVP oversight functions.

b.

Gather data on industry evaluations and Bowles/PQT 03/01/90 Complete programs to incorporate best practices CQAD into Company programs.

Identify desired changes in nuclear Bowle-/PQT 08/01/90 Complete c.

evaluation and oversight functions and CQAD attendant organizational structures.

d.

Implement desired changes in nuclear Eury 12/31/90 Complete evaluation and oversight functions and EVP attendant organizational structures.

REVISE PTS FOR PROPER EVALUATION Moyer 04/28/90 Complete An Independent Review has been completed by BNP Site QA. This E6 OF SERVICE WATER PUMP Operations Action Item has been closed by the PERFORMANCE NRC. Report 90-32, dated 10/18/90.

IAPS3

  • Indicates change from last month's report.

21

\\

O BRUNSWICK NUCLEAR PROJECT INTEGRATED ACTION PLAN STATUS: April 30,1991 l

ORIGINAL TARGET IAP NO.

ACTION ITEM MANAGER DATE DATE COMMENTS FI IMPLEMENT CAREER DEVELOPMENT Ferguson 06/30/90 Complete An Independent Review is AND JOB ROTATION PROCESS NiiRSS underway by Management Services.

Development of program recommendations for management i

review has required more time and effort than was originally l

anticipated.

F2 INCORPORATE QUALIT'/, SAFETY AND Starkey 06/30/90 Complete An Independent Review has been COST EFFECTIVENESS CPITERIA IN BNP completed by Management Services.

PERFORMANCE APPRAISAL PROGRAM F3 REVIEW AWARDS AND INCENTIVES, Ferguson 12/31/90 Complete An Independent Review is POSSIBILITIES AND DEVELOP NIIRSS underway by Management Services.

IMPLEMENTATION PLAN FOR ENIIANCEMENTS F4 PROVIDE FORMAL TRAINING IN Simpson 03/31/90 Complete An Independent Review has been BUSINESS FUNDAMENTALS C&A completed by Management Services.

GI IMPLEMENT ACTIONS TO RESOLVE Simpson 02/28/90

' Complete

'The CP&L employee suggestion PEOPLE ISSUES, INCLUDING EMPLOYEE C&A system, called " Great Ideas At Work," was in place as of April 30, f

SUGGESTION SYSTEM 1991. The first employee suggestion at Brunswick under this program f

was received on May 1,1991. The f

NRC considers this Action item

" ope n."

a.

Establish a system for employees to Simpson 02/28/90

' Complete make suggestions to management.

C&A IAPS3

' Indicates change from last month's report.

22

BRUNSWICK NUCLEAR PROJECT l

INTEGRATED ACTION PLAN STATUS: April 30,1991 l

' ORIGINAL TARGET IAP NO.

ACTION ITEM '

MANAGER DATE DATE CONI 51ENTS l

t b.

Provide for effective follow-up by -

Simpson 02/28/90

  • Complete f

j.

management to suggestions C&A i-

[

c.

Ensura that cost-effectiveness is the key Simpson 02/28/91

  • Complete focus of the suggestion system.

C&A f

i

?

G2 REEMPHASIZE AND ENCOURAGE Simpson 03/31/90 Complete An Independent Review has been SUPPORT OF TQ PROCESS CAA completed by Audit Services. This

}

Action Item has been closed by the l

NRC, Report 90-37, dated j

16/18/90.

[

i G3 IMPROVE ORGANIZATIONAL AND Moyer 03/31/90 Complete An Independent Review is INDIVIDUAL OWNERSiiIP Operations underway by Audit Services. Scope

(

COMMITMENTS, INCLUDING:

expanded to include Nuclear

[

PROCEDURAL ADiiERENCE IN Brown Engineering Dept. efforts in the i

OPERATIONS; AND ATTENTION TO NED area of enginwring design. The

[

DETAIL IN DESIGN ENGINEERING.

NRC considers this Action Item

[

  • open.

i I

i

{

i F

  • Indicates change from last month's report.

IAPS3 23 j

I w

INTEGRATED ACTION PLAN

r-SCHEDULE OF INDEPENDENT ASSESSMENTS
April 30,1991 '

INDEPENDENT APPROXIMATE.

IAP NO.

DESCRIPTION I REVIEW BY SCHEDULE COMMENTS A1 Communication Strategy for Audit Services August 1990 Complete Goals, Pnontres. Expectations A2:

Improve External Relationships C O pO ate O A May 1990 Complete B1 Implement Technical Support Audit Services May 1990 Improvements August 1990 March 1991 Complete B2 Implement NED Organizational Management July 1990 Complete improvements Services B3-Implement Nuclear Training Management June 1991*

Underway Organizational improvements Services B4 Implement Control &

Management June 1991*

Underway Administration Organizational Sennces Improvements B5 Implement Nuclear Plant Management July 1990 Complete Support Organizational Ser', ices improvements B6 Implement Outage Audit Services August 1990 Complete Management & Modifications Organizational improvements

  • Indicates a change from previous month's report.
    • Schedule subject to change based upon availability of resources and shiftng priorities.

IAP-SIR.1 1

I "

J i

INTEGRATED ACTION Pl.AN j -

SCHEDULE OF INDEPENDENT ASSESSMENTS April 30,1991 INDEPENDENT APPROXIMATE l

1AP NO.

DESCRIPTION REVIEW BY SCHEDULE COMMENTS i

87 Construct Permanent Office To be 1993 Building Detennined C1 Implement Corporate Nuclear Management August 1990 Comp!ete Prioritization Process Services I

^

C2 Establish NED Budget item for Management May 1990 Complete l

Generic Work Services l

Ll C3 Establish Budget & Release Management April 1991 Complete

  • Process for Non-IPBS Services L

Engineering C4 Develop Long Range P!anning Management September 1990 Complete Budgets for Emerging issues /

Services Regulations D1 Resolve Survei!!ance Test Audit Services July 1990 Complete Program Questions l

D2.1 Improve Management of Management July 1990 Complete i

Maintenance Backlog Services D2.2 Strengthen Maintenance Management July 1990 Complete i-Planning Functions Services D3 Fine Tune MOV Maintenance On-Site Nuclear To be determined On hold, pending CP&L's Program Assessment

  • response to NRC questions i
  • Indicates a change from previous month's report.

l

    • Schedule subject to change based upon availability of resources and shifting priori *ies.

1 IAP-SIR.1 2

l J

INTEGRATED ACTION PLAN SCHEDULE OF INDEPENDENT ASSESSMENTS April 30,1991 INDE"ENDENT APPROXIMATE IAP NO.

DESCRIPTION.

REVIEW BY SCHEDULE COMMENTS D4 Develop Post-Maintenance BNP Site OA July 1990 Complete Testing for ASME Code Repairs D5 Implement Recommendations On-Site Nuclear June 1991 of HPCI Reliability-Centered Assessment

  • Maintenance Study D6 Address Service Water System On-Site Nuclear May 1991 Undervray*

Design issues Assessment

  • 1 D7 Confirm Design Basis for Key On-Site Nuclear 1994 Brunswick Systems Assessment
  • D8 Complete Update of Corporate Audit Services May 1990 Complete and Site Design Procedures 1

D9 Implement Corrective Action On-Site Nuclear April 1991 Complete

  • Program improvements Assessment
  • D10 Develop and Institutionalize On-Site Nuclear April 1991 Complete
  • Corporate Correc.ve Action Assessment
  • r Program j

D11 Develop Corporate Program for BNP Site OA December 1990 Complete Cons % tent Performance of Safety Reviews

  • Indicates a change from previous month's report.
    • Schedule subject to change based upon availability of resources and siffting priorities.

IAP-SIR 1 3

w.

INTEGRATED ACTION PLAN SCHEDULE OF INDEPENDENT ASSESSMENTS April 30,1991 INDEPENDENT APPROXIMATE LAP NO.

DESCRIPTION REVIEW BY SCHEDULE COMMENTS D12 Improve Business Planning Management August 1990 Complete Process Sentices D13 Review BNP Procedures for Audit Services May 1990 Complete i

Compliance with PAM Intent D14 Improve Consistency of Management June 1991*

Underway Procurement Processes by Services Nuclear Plants D15 Require Nuclear Services Management February 1991 Complete l

Department involvement in Services Regulatory Modifications D16.1 increase Role of Nuclear Plant Management June 1990 Complete Support in Development of Services Consistency among Nuclear Plants D16.2 Formalize initiatives to Management July 1990 Complete Standardize Processes and Services Procedures D17 increase Use of ISD's Management May 1990 Complete Directives and Resources Services

  • Indicates a change from previous month's report.
    • Schedule subject to change based upon availability of resources and shifting priorities.

4 IAP-SIR.1 i

i l

INTEGRATED ACTION PLAN i

SCHEDULE OF INDEPENDENT ASSESSMENTS April 30,1991 l-INDEPENDENT APPROXIMATE IAP NO.

DESCRIPTION REVIEW BY SCHEDULE COMMENTS l

D18 Submit Simulator Certification On-Site May 1991 Underway

  • Nuclear i

Assessment

  • j D19.1 Implement System for Management June 1991*

Underway Responding to Training Services Requests i

D19.2 Provide Coordinated Response Management June 1991*

Undervraf to Regulatory-related Training Services Requests D20 Revise Standing Instructions Corporate OA May 1990 Complete Procedure to Require Index Log D21 Review SWFCG Charter / Guides Management August 1990 Complete for Current Goals, Priorities Services D22 Implement Tagging and Audit Services May 1990 Complete Labeling improvement Program D23 Integrate PM Vibration Program On-Site November 1991*

with ASME Sec. XI !ST Program Nuclear Assessment

  • D24 Implement Budgeting of Small Management May 1990 Complete Engineering Support Projects Services
  • Indicates a change from previous month's report.
    • Schedule subject to change based upon availability of resources and shifting priorities.

IAP-SIR.1 5

f O

INTEGRATED ACTION PLAN SCHEDULE OF INDEPENDENT ASSESSMErfrS April 30,1991 INDEPENDENT

. APPROXIMATE IAP NO.

DESCRIPTION REVIEW BY SCHEDULE COMMENTS i

4 D25 Use Project Management Audit Services August 1990 Complete Approach in 4

Planning / Execution of Outages D26 Formalize Plant Work Schedule Management June 1990 Complete Adherence Control Senrices D27 Improve Tracking / Disposition BNP Site OA July 1990 Complete of Temporary Repairs / Conditions to Expedite Elimination D28 Revise EOPs to Simplify and On-Site Nuclear April 1991*

Complete

  • Match BWROG Guidelines Assessment
  • i

' D29 Implement NGG Guideline Re:

BNP Site OA August 1990 Complete Structure of CP&L ISI Programs, and Establishment of 6-Month Information Exchanges D30 Implement Actions for Management August 1990 Complete Administrative Ccst Sen, ices Containmcist

  • Indicates a change from previous month's report.
    • Schedule subject to change based upon availability of resources and shifting priorities.

IAP-SIR.1 6

7 I

IH II I III E INTEGRATED ACTION PLAN SCHEDULE OF INDEPENDENT ASSESSMENTS April 30,1991 INDEPENDENT APPROXIMATE IAP NO.

DESCRIPTION REVIEW BY SCHEDULE COMMENTS D31 Consolidate, Update, Simplify Audit Services March 1991 Complete l

BNP Procedures D32 Implement Brunswick Nuclear To be determined Project Department Ucensed Operator Training improvements D33 Implement Nuclear Services To be determined Department Licensed Operator Training improvements E1 Define, Track Operational and Audit Services August 1990 Complete Management Performance; Document Goals to be Used to Manage Performance E2 Ensure improvement Programs Management August 1990 Complete Are implemented / Monitored Services E3 Revise LOR Program, BNP Site OA July 1990 Complete Emphasizing Effective Control Room Log Entries E4.1 issue Integrated Audit Services May 1991 Underway Audit / Surveillance Plan for BNP Engineering

  • Indicates a change from previous month's report.
    • Schedule subject to change based upon availability of resources and shifting priorities.

7 IAP-SIR.1

(

?

l INTEGRATED ACTION PLAN

- SCHEDULE OF INDEPENDENT ASSESSMENTS April 30,1991 INDEPENDENT APPROXIMATE IAP NO.

DESCRIPTION REVIEW BY SCHEDULE COMMENTS E4.2 Develop Corporate OA Audit Services May 1991 Underway Performance-Based Overview Plan E4.3 Adjust Audit improvements in Audit Services August 1990 Complete Progress to Address DET Conclusions E5 Analyze Methods of Audit Services May 1991*

Underway

  • Independent Assessments for Performance Evaluation E6 Revise pts for Proper BNP Site OA July 1990 Complete Evaluation of Service Water Pump Performance F1 Implement Career Development Management June 1991*

Underway and Job Rotation Process Services F2 Incorporate Quality, Safety and Management August 1990 Complete Cost Effectiveness Criteria in Services Performance Appraisal Program F3 Review Awards and incentives; Management June 1991*

Underway Develop Plans for.

Sen/tces Enhancements

  • Indicates a change from previous month's report.
    • Schedule subject to change based upon availability of resources and shifting priorities.

IAP-SIR.1 8

  1. o

.o INTEGRATED ACTION PLAN SCHEDULE OF INDEPENDENT ASSESSMENTS April 30,1991 INDEPENDENT APPROXIMATE IAP NO.

DESCRIPT!ON REVIEW BY SCHEDULE COMMENTS F4 Provide Formal Training in Management July 1990 Complete Business Fundamentals Services G1 Implement Actions to Resolve Audit Services May 1991 Revised due to change in People issues, including completion date of Action item.

Employee Suggestion System G2 Reemphasize and Encourage Audit Services August 1990 Complete Support of TO Process G3 Improve Organizational and Audit Services May 1991 Underway Individual Ownership Commitments, including Procedural Adherence

  • Indicates a change from previous month's report.
    • Schedule subject to change based upon availability of resources and shifting priorities.

IAP-SIR.1 9