_._ _

tM Og A

r 4

S UNITED STATES 5

NUCLEAR REGULATORY COMMISSION k..... e#

WASHINGTON, D.C. 2055W1 PHILADELPHIA ELECTRIC COMPANY DOCKET NO. 50-352 LIMERICK GENERATING STATION. UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 83 License No. NPF-39 l

l 1.

The Nuclear Regulatory Comission (the Comi sion) has found that:

A.

The application for amendment by Philadelphia Electric Company (the licensee) dated July 22, 1994, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),

l and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by I

this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

l 9501030166 941219 i

PDR ADOCK 05000352 l

P PDR 1

i

4

}

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-39 is hereby amended to read as follows:

Technical Soecifications The Technical Specifications contained in Appendix A and the Environmental i

Protection Plan contained in fa endix B, as revised through Amendment No.

83, are hereby incorporated

.o this license.

Philadelphia Electric l

Company shall operate the facility in accordance with the Technical i

Specifications and the Environmental Protection Plan.

i 3.

This license amendment is effective as of its date of issuance.

4 FOR THE NUCLEAR REGULATORY COMMISSION

[

o n F. Stolz, Dire or P oject Directorate I-2 ivision of Reactor Projects - I/II

]

Office of Nuclear Reactor Regulation i

Attachment:

Changes to the i

Technical Specifications i

Date of Issuance:

December 19, 1994 i

I i

3

l.

ATTACHMENT TO LICENSE AMENDMENT N0. 83 FACILITY OPERATING LICENSE N0. NPF-39 DOCKET NO. 50-352 Replace the following page of the Appendix A Technical Specifications with the attached page. The revised page is identified by Amendment number and contains vertical lines indicating the area of change.

Remove Insert 3/4 6-4 3/4 6-4 l

l

i CONTAINMENT SYSTEMS j

SURVEILLANCE REQUIREMENTS (Continued)

)

d.

Type B and C tests shall be conducted with gas at P., 44.0 psig*, at a frequency in accordance with 10 CFR 50, Appendix J, as modified by approved exemptions, except for tests invoiving:

1.

Air locks, 2.

Main steam line isolation valves, 3.

Containment isolation valves in hydrostatically tested lines which penetrate thc' primary containment, and e.

Air locks shall be tested and demonstrated OPERABLE per Surveillance l

Requirement 4.6.1.3.

1 f.

Main steam line isolation valves shall be leak tested at a frequency in accordance with 10 CFR 50, Appendix J, as modified by approved exemptions.

g.

Containment isolation valves in hydrostatically tested lines which I

penetrate the primary containment shall be leak tested at least once per 24 months, not to exceed the requirements of 10 CFR 50, Appendix J.

j h.

The provisions of Specification 4.0.2 are not applicable to Specifica-tions 4.6.1.2a., 4.6.1.2b., 4.6.1.2c., 4.6.1.2d., 4.6.1.2e., and 4.6.1.2f. l 2

4 4

i 1

f 4

i

$Unless a hydrostatic test is required per Table 3.6.3-1.

LIMERICK - UNIT 1 3/4 6-4 Amendment No. 2, 33, 71, 83 9

4

4 1

t na cao 8

o go n,,

4 4

o UNITED STATES 3

i NUCLEAR REGULATORY COMMISSION

{

(**..+/

' WASHINGTON, D.C. 20555-0001

]

j PHILADELPHIA ELECTRIC COMPANY j

DOCKET NO. 50-353 LIMERICK GENERATING STATION. UNIT 2 i

AMENDMENT TO FACILITY OPERATING LICENSE j

Amendment No. 44 i

License No. NPF-85 1

1.

The Nuclear Regulatory Comission (the Commission) has found that:

l A.

The application for amendment by Philadelphia Electric Company (the j

licensee) dated July 22, 1994, complies with the standards and I

requirements of the Atomic Energy Act of 1954, as amended (the Act),

and the Comission's rules and regulations set forth in 10 CFR j

Chapter I;

}

B.

The facility will operate in conformity with the application, the i

provisions of the Act, and the rules and regulations of the j

Comission; l

C.

There is reasonable assurance (i) that the activities authorized by

{

this amendment can be conducted without endangering the health and i

safety of the public, and (ii) that such activities will be conducted

)

in compliance with the Comission's regulations;

{

D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; and 1

l E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of j

the Comistion's regulations and all applicable requirements have been i

satisfied.

i;

)

i k

b e

l

, l 2.

Accordingly, the license is amended by changes to the Technical l

Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-85 is hereby amended to read as follows:

Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No.

44, are hereby incorporated into this license.

Philadelphia Electric Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

l 3.

This license amendment is effective as of its date of issuance.

FOR THE NUCLEAR REGULATORY C0fMISSION o n F. Stolz, Dir or 1

oject Directorate I-2 i

Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation j

Attachment:

Changes to the Technical Specifications Date of Issuance: December 19, 1994 l

~

ATTACHMENT TO LICENSE AMENDMENT NO. 44 FACILITY OPERATING LICENSE NO. NPF-85 DOCKET NO. 50-353 Replace the following page of the Appendix A Technical Specifications with the attached page. The revised page is identified by Amendment number and contains vertical lines indicating the area of change.

Remove Insert 3/4 6-4 3/4 6-4 i

l

! ' ' CONTAINMENT SYSTEMS j

ELRyElllANCE REOUIREMENTS (Continued) 1 d.

Type B and C tests shall be conducted with gas at P., 44.0 psig*, at a frequency in accordance with 10 CFR 50, Appendix J, as modified by approved exemptions, except for tests involving:

i 1.

Air locks, 2.

Main steam line isolation valves, 3.

Containment isolation valves in hydrostatically tested lines which penetrate the primary containment, and e.

Air locks shall be tested and demonstrated OPERABLE per Surveillance Requirement 4.6.1.3.

3 l

f.

Main steam line isolation valves shall be leak tested at a frequency in accordance with 10 CFR 50, Appendix J, as modified by approved i

exemptions.

g.

Containment isolation valves in hydrostatically tested lines which penetrate the primary containment shall be leak tested at least once per 24 months, not to exceed the requirements of 10CFR50, Appendix J.

1 4

h.

The provisions of Specification 4.0.2 are not applicable to Specifica-tions 4.6.1.2a., 4.6.1.2b., 4.6.1.2c., 4.6.1.2d., 4.6.1.2e., and 4.6.1.2f.

4 J

i 4

I

.[

oUnless a hydrostatic test is required per Table 3.6.3-1.

I f

LIMERICK - UNIT 2 3/4 6-4 Amendment No. 34, 44