a
, :a e
-e' TECHNICAL SPECIFICATIONS
'Rhode Island Nuclear Science Center Docket 50-193, License R-95 Revision 1 I
- Annual pool. system inspections are made to provide assurance that other cooling system components (eg. gate valves, gasketing etc.) are functioning properly.
b.
Secondary Coolant System Applicability:
This specification applies to the surveillance of the secondary coolant water.
Objective:
To assure the conditions of the coolant meet specification 3.3.(b) and to detect a primary to secondary water leak.
Specification:
1.
The pH shall be measured weekly during reactor operation.
t 2.
A sample shall be drawn weekly and analyzed for sodium-24 activity, during reactor operation.
Bases:
Proper secondary coolant conditions - are obtained by blowdown and makeup water systems which maintain the proper water quality pH. Radioactive concentrations are measured in accordance with written procedures.
I 1
Auendment No. 19 9412270113 941214 Page 42 PDR ADOCK 05000193 1