NUREG-1021, Revision 11 Rev 1 ES-301 Administrative Topics Outline Form ES-301-1 Facility: Davis Besse Nuclear Power Station Date of Examination: 2/3/2020 to 2/14/2020 Examination Level RO SRO Operating Test Number DB NRC 2020 Administrative Topic (See Note)
Type Code*
Describe activity to be performed Conduct of Operations (RO A 1.1)
D, R 2.1.23 (4.3)
Ability to perform specific system and integrated plant procedures during all modes of plant operation.
Perform a BWST Fill Calculation (JPM-172)
Conduct of Operations (RO A 1.2)
D, R 2.1.25 (3.9)
Ability to interpret reference materials, such as graphs, curves, tables, etc.
Determine the boron concentration needed to ensure 1% SDM with two stuck rods (JPM-272)
Equipment Control (RO A 2)
N, R 2.2.37 (3.6)
Ability to determine operability and/or availability of safety related equipment.
Determine isolation boundary and effect on safety related equipment (JPM-319)
Radiation Control (RO A 3)
D, S 2.3.5 (2.9)
Ability to use radiation monitoring systems, such as fixed radiation monitors and alarms, portable survey instruments, personnel monitoring equipment, etc.
Calculate Steam Generator Tube Leak rate (JPM 316)
Emergency Plan (RO A 4)
NOT EVALUATED NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics (which would require all 5 items).
- Type Codes & Criteria (C)ontrol Room, (S)imulator, or Class(R)oom (D)irect from bank (< 3 for ROs; < 4 for SROs & RO retakes)
(N)ew or (M)odified from bank (> 1)
(P)revious 2 exams (< 1; randomly selected)