Text
s
~
- f. h TIIE CINCINNATI GAS & ELECTRIC COMPANY CINCINN AT1, OHIO 45208 October 6, 1983 LOZ-83-0163 J. WILLI AM S, J R SENICA VICE PRESIDENT NUCLE # R OPERAff0NS Docket No. 50-358 Mr. Harold Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regtilatory Commission Wa3hington, D.C.
20555
Dear Mr. Denton:
RE:
WM. H.
3IMMER NUCLEAR POWER STATION UNIT 1 - NRC REQUEST FOR ADDITIONAL INFORMATi7N: CONTROL OF HEAVY LOADS This letter is in response to NRC letter dated August 11, 1983 from Mr. B. J. Youngblood, which requested additional information on the control of heavy loads pertaining to NUREG-0612, " Control of Heavy Loads at Nuclear Power Plants".
Enclosed with this letter is CG&E's response to the Phase I objective of NUREG-0612, identified in Article 5.1.1.
Very truly yours, THE CINCINNATI GAS & ELECTRIC COMPANY
~
By suc '
LIAM3,"JI NIOR VICE PR IDENT SJT/sfr 8310120252 831006 PDR ADOCK 05000358 3
A PDR g
[
c, Mr. Harold Denton Director October 6, 1983 LOZ-83-0163 Page 2 cc:
John H. Frye III M. Stanley Livingston Frank F. Hooper Troy B. Conner, Jr.
John E. Dolan Steven G. Smith William J. Moran Stephen F. Koziar, Jr.
Samuel H. Porter Gregory C. Ficke T.P.-Gwynn James H. Feldman, Jr.
John D. Woliver Deborah F. Webb David K. Martin George E. Pattison Andrew B. Dennison James P. Fenstermaker L.L. Kintner Lynne Bernabei, Esq.
J.G. Keppler EGEE P.O. Box 1625 Idaho Falls, ID. 83415 ATTN: T.H. Stickley
,i REQUEST The Phase I objective of NUREC-0612, identified in article 5.1.1, is to ensure that all load handling systems at nuclear power plants are designed and operated such that their probability of failure is uniformly small and appropriate for the critical tasks in which they are employed.
Enclosed in Mr. Youngblood's August 11, 1983 letter to CG&E is a report prepared by EG&G, " Control of Heavy Loads at Nuclear Power Plants, Wm. H. Zimmer Nuclear Power Station (PHASE I) ", dated July, 1983.
The report stated that design information is not presented for Item No. 301 (Turbine Building Crane) and that further information is needed.
The report also stated that for Hoist Item 108, the general listings rate the hoist at 18 tons and at 20 tons.
This data should be consistent.
REPLY All cranes and hoists purchased for use at the Wm. H. Zimmer Nuclear Power Station were purchased to Sargent & Lundy (S &L) specifications.
These specifications are based upon various standards applicable at the time of equipment purchase.
Structural requirements were based upon Electric Overhead Crane Institute (EOCI) and American Institute for Steel Construction (AISC) standards for overhead bridge cranes and ANSI B30.ll or ANSI B30.16, as appropriate, for underhung cranes or hoists.
Electrical equipment for motor operated cranes was specified to meet and be tested to applicable United States of America Standards Institute (USASI) standards or ANSI B30.2.0.
In addition, the requirements of CMAA No. 61 or CMAA No. 70 were specified, as well as applicable IEEE and NEMA standards.
Item No. 301 (Turbine Building Crane) was specified per the structural requirements of EOCI and AISC standards for overhead bridge cranes.
The electrical crane equipment for Item No. 301 was specified to meet USASI standards, and the requirements of CMAA No. 61.
Item No. 108 (Main Steam Isolation Valve Hatch Slab Hoist) was specified per the structural requirements of ANSI B30.16.
The electrical motor equipment for Item No. 108 was specified to meet ANSI B30.2.0, and the requirements of CMAA No. 70.
Item No. 108 is rated at 20 Tons.
1
h 4
j LOZ-83-0163 Attachment Page 2 Additional clarification applies to Item No. 101.
The June 1, 1983 CG&E report, "Wm. H. Zimmer Nuclear Power Station-Unit 1, Heavy Loads Report", stated that Item No. 101 (Reactor Building Crane) was specified per the requirements of CMAA.
The Sargent & Lundy purchase specification stated that electrical equipment for motor operated cranes meet the requirements of CMAA No. 61.
Item No.101 was not specified to meet the requirements of CMAA No. 70.