n THF ELE CTAeC COMPANY OLENN L ROESTER v<s rettactrof. e.gcLean September 9, 1983 Mr. W.C. Seidle, Chief
[h],I Reactor Projects Branch 2 l
U.S. Nuclear Regulatory Commission Region IV f
611 Ryan Plaza Drive, Suite 1000 SEP l 21933 lf d Arlington, Texas 76011 t
L./
L KMLNRC 83-117 Re:
Docket No. STN 50-482 Ref: I&E Bulletin 83-06, Nonconfonning Materials Supplied by Tube-Line Corporation, dated 7/22/83 Subj: Interim Potential 10CFR50.55(e) Report -
Tube-Line
Dear Mr. Seidle :
This letter provides an interim report on a poter.tial 10CFR50.55(e) matter concerning fittings manufactured by the Tube-Line Corporation.
This item was initially reported to Mr. William Johnson of the Nuclear Regulatory Commission, Region IV, by Mr. Otto Maynard of Kansas Gas and Electric Company (KG&E) on August 12, 1983.
As a result of the information provided in the Reference, KG&E identified seven elbows installed or in the warehouse that were manufactured by the Tube-Line Corporation. All seven elbows were ordered for safety-related applications. Two elbows (4 inch, 45 degree, ASTM-A-234, schedule 40, ASME III, Class 3, Heat No. EUDC) were in the warehouse and have been placed on hold. Four elbows (8 inch, 45 degree, ASTM-A-234, schedule 40, ASME III, Class 3, Heat No. EWTQ) were installed in the component Cooling Water System. These four elbows have been cut out and replaced with safety-related elbows from another manufacturer. The seventh elbow (4 inch, 90 degree, ASME-SA-234, schedule 80, ASME III, Class 2, Heat No. EXJN) was installed in the Auxiliary Feedwater System. This elbow has also been replaced with a safety-related elbow from another manufacturer.
Although KG&E believes that the seven elbows described above are the only safety-related fittings that were procured from Tube-Line Corporation, the investigation of this concern has not been concluded. The status of this investigation will be reported to you on or before November 25, 1983.
8309160303 030909 PDR ADOCK 05000492 S
PDR j [- X?
201 N. Market ~ Wictwts. Kansas - Mad Address: PC. Box 208 i Wchsta, Kansas 67201 - Telephone: Area Code (316) 261-6451
Y k
Mr. W.C. Seidle KMLNRC 83-117 September 9, 1983 In the interim, please direct any questions concerning this subject to me or to Mr. Otto Maynard of my staff.
Yours very truly, Glenn L. Koester Vice President - Nuclear GLK:bb cc: RCDeYoung WSchum/ASmith