MCEI-0400 47

/hy/

Page 1 of 19' 8, ;

Revision 3

~f-1 McGuire Unit 2 Cycle 10 Core Operating Limits Report December 1994 Duke Power Company Date Prepared By:.2 M9 CECW II

/d L-O

/z/9/t</

/

Checked By:

Checked By:

OkUA %. @a<r

/2-/4/9+

v u

Approved By:

[7V68aad___

/EN'NV 1

QA Condition 1 NOTE The contents of this document have been reviewed to verify that no material herein either directly or indirectly changes or affects the results and conclusions presented in the 10CFR50.59 M2C10 Reload Safety Evaluation (calculation file: MCC-1552.08-00-0250).

9412150211 941209 DR ADOCK 05000370 PDR

MCEl-0400-47 Page 2 of 19 Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report REVISION LOG Revision Effective Date Effective Paces COLR OriginalIssue August 25,1993 N/A M2C09 Revision 1 June 20,1994 N/A M2C09, Rev.1 Revision 2 October 18,1994 N/A M2C09, Rev. 2 Revision 3 December 9,1994 Pages 1 - 19 M2C10 1

l 1

l l

1 1

l

MCE14)40047

. Page 3 of 19 Revision 3

' McGuire 2 Cycle 10 Core Operating Limits Report INSERTION SIIEET FOR REVISION 3 Remove pages Insert Rev. 3 pages Pages 1 - 153 Pages 1 - 19 e

J i

l

m..

4 MCEI-0400-47 Page 4 of 19 Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report -

'l 1.0 Core Operating Limits Report This Core Operating Limits keport, (COLR), for McGuire, Unit 2, Cycle 10 has been

- prepared in accordance with the requirements of Technical Specification 6.9.1.9.

The Technical Specifications affected by this report are listed below:

Technical Specifications Section Page 2.2.1 - Reactor Trip System Instrumentation Setpoint 2.0 5

3/4.1.1.3 - Moderator Temperature Coefficient 3.0 7

3/4.1.2.5 - Borated Water Source - Shutdown 3.1 9

3/4.1.2.6 - Borated Water Source - Operating 3.2 10 3/4.1.3.5 - Shutdown Rod Insertion Limit 3.3 10 1

3/4.1.3.6 - Control Rod Insertion Limit 3.4 10 3/4.2.1 - Axial Flux Difference 3.5 10 3/4.2.2 - Heat Flux Hot Channel Factor 3.6 13 3/4.2.3 - Nuclear Enthalpy Rise Hot Channel Factor 3.7 16 3/4.5.1.1 - Accumulators 3.8 18 3/4.5.5 - Refueling Water Storage Tank 3.9 18 3/4.9.1 - Refueling Operations - Boron Concentration 3.10 19 3/4.9.12 - Fuel Storage - Spent Fuel Storage Pool 3.11 19 4

MCEl-040047 Page 5 of t9 '

Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report 1.1 Operating Limits The cycle-specific parameter limits for the specifications listed in section 1.0 are presented in the following subsections. These limits have been developed using NRC approved methodologies specified in Technical Specification 6.9.1.9.

2.0 Tech Spec 2.2.1 - Reactor Trip System Instrumentation Setpoints 2.0.1 Overtemperature AT Setpoint Parameter Values Parameter Value Overtemperature AT reactor trip setpoint K1 s 1.1988 Overtemperature AT reactor trip heatup K2 = 0.03354/0F setpoint penalty coefficient K = 0.001522/ psi Overtemperature AT reactor trip 3

depressurization setpoint penalty coefficient Measured reactor vessel ATlead/ lag time t 2 8 sec.

1 t s 3 sec.

constants 2

Measured ATlag time constant t s 2 sec.

3 Measured reactor vessel average temperature T 2 28 sec.

4 lead / lag time constants T s 4 sec.

5 Measure reactor vessel average temperature T s 2 sec.

6 lag time constant f (AI) " positive" breakpoint

= 12.0 %Al i

f (AI) " negative" breakpoint

= -44.0 %Al 3

f (AI) " positive" slope

= 1.619 %ATg %AI i

f (AI) " negative" slope

= 3.436 %ATg %Al i

)>-

s MCEI-040047 Page 6 of 19 Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report 2.0.2 Overpower AT Setpoint Parameter Values Parameter Value K s 1.0851 Overpower AT reactor trip setpoint 4

Overpower AT reactor trip heatup setpoint K6 = 0.001207FF penalty coefficient Measured reactor vessel ATlead/ lag time T 2 8 sec, 1

T s 3 sec.

constants 2

t s 2 sec.

f Measured ATlag time constant 3

Measure reactor vessel average temperature t s 2 sec, 6

lag time constant Measure reactor vessel average temperature T 2 5 sec.

7 rate-lag time constant 4

f (AI) " positive" breakpoint

= 35.0 %AI 2

f (AI) " negative" breakpoint -

= -35.0 %AI 2

f (AI) " positive" slope

= 7.0 %ATg %AI 2

f (AI) " negative" slope

= 7.0 %ATg %AI 2

I 6

4 6

e k

t f

-r-

-r n

MCEl-0400-47 Page 7 of 19 Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report 3.0 Tech Spec 3/4.1.1.3 - Moderator Temperature Coefficient 3.0.1 The Moderator Temperature Coefficient (MTC) Limits are:

The MTC shall be less positive than the limits shown in Figure 1. The BOC, ARO, HZP MTC shall be less positive than 0.7E-04 AK/K/ F.

The EOC, ARO, RTP MTC shall be less negative than -4.1E-04 AK/K/ F.

3.0.2 The MTC Surveillance Limitis:

The 300 PPM ARO, RTP MTC should be less negative than or equal to -3.2E-04 AK/K/ F.

Where:

BOC stands for Beginning of Cycle EOC stands for End of Cycle ARO stands for All Rods Out HZP stands for Hot 7s;o Thermal Power RTP stands for Raien Thermal Power E

\\

t

a.

- - _ ~

MCEI-040047 Page 8 of 19 Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report t

I

-l 0.9

{ 0.7 0.8 Unacceptable Operation uR h 0.6 ea Acceptable Operation b

0.5 a8 g 4 0.4 N 0.3

.Sg 0.2 0.1 0

0 10 20 30 40 50 60 70 80 90 100 Percent of Rated Thermal Power Figure 1 Moderator Temperature Coefficient Versus Power Level NOTE: Compliance with Technical Specification 3.1.1.3 may require rod withdrawal limits.

j Refer to OP/2/A/6100/22 Unit 2 Data Book for details.

j

l MCEI-0400-47 Page 9 of 19 Revision 3 1

McGuire 2 Cycle 10 Core Operating Limits Rep 6rt J

3.1 Tech Spec 3/4.1.2.5 - Borated Water Source - Shutdown 3.1.1 Volume and boron concentrations for the Boric Acid Storage System and the Refueling Water Storage Tank (RWST) during modes 5 & 6:

Parameter Limil Boric Acid Storage System minimum contained 6,132 gallons borated water volume for LCO 3.1.2.5a 6.7% level Boric Acid Storage System minimum baron 7,000 ppm concentration for LCO 3.1.2.5a Boric Acid Storage System minimum water volume 585 gallons required to maintain SDM at 7,000 ppm Refueling Water Storage Tank minimum contained 26,000 gallons borated water volume for LCO 3.1.2.5b 33.3 inches Refueling Water Storage Tank minimum boron 2,175 ppm concentration for LCO 3.1.2.5b Refueling Water Storage Tank minimum water 3,500 gallons volume required to maintain SDM at 2,175 ppm "Y

y

+

rw m+--gu=-se1 r-mw--r'-r'29-M~

e -,.-

-zt em-e-w

i MCEI-0400-47 i

Page 10 of 19 Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report 3.2 ~

Tech Spec 3/4.1.2.6 - Borated Water Source - Operating 3.2.1 Volume and boron concentrations for the Boric Acid Storage System and the Refueling Water Storage Tank (RWST) during modes 1,2,3, & 4:

J Parameter Linnt Boric Acid Storage System minimum contained 20,453 gallons borated water volume for LCO 3.1.2.6a 38.5% level Boric Acid Storage System minimum boren 7,000 ppm concentration for LCO 3.1.2.6a j

Boric Acid Storage System minimum water volume 9,851 gallons j

required to maintain SDM at 7,000 ppm 1

Refueling Water Storage Tank minimum contained 91,000 gallons borated water volume for LCO 3.1.2.6b 116.4 inches Refueling Water Storage Tank minimum boron 2,175 ppm concentration for LCO 3.1.2.6b l

Refueling Water Storage Tank maximum boron 2,275 ppm concentration for LCO 3.5.5b Refueling Water Storage Tank minimum water 57,107 gallons volume required to maintain SDM at 2,175 ppm 3.3 Tech Spec 3/4.1.3.5 - Shutdown Rod Insertion Limit 3.3.1 The shutdown rods shall be withdrawn to at least 222 steps.

3.4 Tech Spec 3/4.1.3.6 - Control Rod Insertion Limits 3.4.1 The control rod banks shall be limited to physical insertion as shown in Figure 2.

j i

3.5 Tech Spec 3/4.2.1 - Axial Flux Difference 3.5.1 The Axial Flux Difference (AFD) Limits are provided in Figure 3.

i l

)

MCEI-0400-47 Page 11 of 19 Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report 1

(Fully Withdrawn min - 222, max - 230) i

'fi (29.1%,230)

(79.6 %,230) 220

,u 200

',ng 3 f

j g

1%

160 -

(0%,163)

(100 %,161) h f

RM 140 Insertion

/

Bank c f

Position 120 f

(Steps 100 Withdrawn) 80 f'f Bank D 60

/

40 -

(0%,47)

,/

20

-/

(30%,0) 0 10 20 30 40 50 60 70 80 90 100 (Fullyinserted)O Relative Power (Percent)

Figure 2 Control Rod Bank Insertion Limits Versus Percent Rated Thermal Power NOTE: Compliance with Technical Specification 3.1.1.3 may require rod withdrawal limits.

Refer to OP/2/A/6100/22 Unit 2 Data Book for details. If reactor power is turbine limited, a penalty of 2.3 steps for each percent power below 100% to which the reactor is limited will be required. Refer to OP/2/A/6100/22 Unit 2 Data Book for details.

MCEI-(M0047 Page 12 of 19 Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report A.F. D. LIMrr CURVE 120 110 --

D l (.I8,100)l

. ~.

(+10,t00) g m

90 --

T l Unacceptable operation l g

80 -

junacceptable opentionl g

l Aceptaie openti=l 70 --

.g g.

l (+21.50)l

  • E l (.36.50)l 50 --

o 40 -

j 30 --

}

20 -

10 --

l l

l l

0 l

l l

-50

-40

-30 20

-10 0

10 20 30 40 50 Axial Flux Difference (% Delta I)

Figure 3 Percent of Rated Theimal Power Versus Axial Flux Difference Limits NOTE: Compliance with Technical Specification 3.2.2 may require more restrictive AFD limits. Refer to OP/2/A/6100/22 Unit 2 Data Book for details.

l i

i

MCEI-040047 Page 13 of 19 Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report 3.6 Tech Spec 3/4.2.2 - lieat Flux Ilot Channel Factor, FQ(X,Y,Z) 3.6.1 F

= 2.32 q

3.6.2 K(Z) is provided in Figure 4 for MkBW fuel.

The ' ollowing parameters are required for core monitoring per the Surveillance Requirements of f

Specification 3/4.2.2:

[h(X,Y,Z)]OP = p (X,Y,Z) x M (X,Y,Z)/(UMT x MT x TILT)

D 3.6.3 q

q Q

where:

[h(X,Y,Z)]OP = cycle dependent maximum allowable design peaking factor which q

ensures that the FQ(X,Y,Z) limit will be preserved for operation within the LCO limits [h(X,Y,Z)]OP, ((Q(x,y,z))OP includes q

allowances for calculational and measurement uncertainties.

the design power distribution for FQ. [q(X,Y,Z) is provided i F (X,Y,Z) =

q Table 1, Appendix A, for normal operating conditions and in Table 2, Appendix A for power escalation testing during initial startup operations.

MQ(X,Y,Z) =

the margin remaining in core location X,Y,Z to the LOCA limit in the transient power distribution. MQ(X,Y,Z) is provided in Table 1, Appendix A for normal operating conditions and in Table 2, Appendix A for power escalation testing during initial startup operations.

UMT=

Measurement Uncertainty, = 1.05.

MT=

Engineering Hot Channel Factor, = 1.03.

TILT =

Peaking penalty that accounts for allowable quadrant power tilt ratio of 1.02. (TILT = 1.035)

NOTE: [lb(X,Y,Z)]OP is the parameter identified as F (X,Y,Z) in DPC-NE-2011PA.

g

MCEI-0400-47 Page 14 of 19 Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report

[h(X,Y,Z)]RPS =

3.6.4

(.X,Y,Z) x (M (X,Y,Z)/(UMT x MT x TILT))

C q

where:

[h(X,Y,Z)]RPS = cycle dependent maximum allowable design peaking factor which q

ensures that the centerline fuel melt limit will be preserved for operation within the LCO limits. [h(X,Y,Z)]RPS ncludes i

q allowances for calculational and measurement uncertainties.

[q(X,Y,Z) =

the design power distributions for FQ. [q(X,Y,7-) is provided Table 1, Appendix A for normal operating conditions and in Table 2, Appendix A for power escalation testing during initial startup operations.

M (X,Y,Z) =

the margin remaining to the CFM limit in core location X,Y,Z C

from the transient power distribution. M (X,Y,Z) calculations C

parallel the M (X,Y,Z) calculations described in DPC-NE-Q 2011PA, except that the LOCA limit is replaced with the CFM limit. M (X,Y,Z)is provided in Table 3, Appendix A for normal C

operating conditions and in Tab!c 4, Appendix A for power escalation testing during initial startup operations.

UMT=

Measurement Uncertainty, = 1.05.

MT=

Engineering Hot Channel Factor, = 1.03.

TILT =

Peaking penalty that accounts for allowable quadrant power tilt ratio of 1.02. (TILT = 1.035)

NOTE: [h(X,Y,Z)]RPS is the parameter identified as (X,Y,Z) in DPC-NE-2011PA, q

except that Mo(X,Y,7) is replaced by Mc(X,Y,Z).

3.6.5 KSLOPE = 0.0725 KSLOPE is the adjustment to the Kj value from OTAT required to compensate for each 1% that [h(X,Y,Z)]RPS exceeds its limit.

q i

MCEI4100-47 Page 15 of 19 Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report (0,0,1.0) 1.00 (12.0A91)

=

0'90 (8.0.1.0)

(9.71 A96) 0.80 --

0.70 --

R y 0.60 -

0.50 --

j 0.40 --

0.30 -

0.20 --

0.10 --

0.00 l

l l

l l

0 2

4 6

8 10 12 Core lleight (ft.)

Figure 4 K(Z), Normalized FQ(X,Y,Z) as a Function of Core Height for MkBW Fuel

MCEl-0400-47 Page 16 of 19 '

Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report 3.7 Tech Spec 3/4.2.3 - Nuclear Enthalpy Rise Hot Channel Factor, FAH(X,Y,Z) 1 The following parameters are required for the LCO requirements of T.S. 3/4.2.3.

3.7.1 [FAH(X,Y)]LCO = MARP (X,Y) x [1.0 + (1/RRH) x (1.0 - P)]

1 where:

f MARP(X,Y) = McGuire 2 Cycle 10 Operating Limit Maximum Allowable Radial Peaks. MARP(X,Y)) radial peaking limits, are provided in Table 7 Appendix A.

i Thermal Power P = Rated Thermal Power RRH is defined in section 3.7.3 4

The following parameters are required for core monitoring per the Surveillance requirements of T.S. 3/4.2.3.

D 3.7.2 [FAH(X,Y)]SURV = p H(X,Y) x MAH(X,Y)/(UMR x TILT) where:

L

[FAH(X,Y)]SURV = cycle dependent maximum allowable design peaking factor

^

which ensures that the FAH(X,Y) limit will be preserved for.

operation within the LCO limits. [FAH(X,Y)]SURVincludes allowances for calculational and measurement uncertainty.

D D

FAH(X,Y) =

the design power distribution for FAH.FAH(X,Y)is provided in Table 5, Appendix A for normal operation and in Table 6, Appendix A for power escalation testing during initial startup i

operatior s.

MCEI-040047

(

Page 17 of 19 Revision 3.

McGuire 2 Cycle 10 Core Operating Limits Report MAH(X,Y) =

the margin remaining in core location X,Yfrelative to the Operational DNB limit in the transient power distribution.

MAH(X,Y) is provided in Table 5, Appendix A for normal operation and in Table 6, Appendix A for power escalation testing during initial startup operations.

1 UMR=

Uncertainty value for measured radial peaks, = 1.04.

TILT =

Factor to account for a peaking increase due to the allowed quadrant tilt ratio of 1.02. (TILT = 1.035).

H(X,Y)]SURV s the parameter identified as [FAH(X,Y)] MAX n DPC-NE-i i

NOTE: [F 20llPA.

3.7.3 RRH = 3.34 when 0.0 < P s 1.0, where:

I RRH =

Thermal Power reduction required to compensate for each 1% that FAH(X,Y) exceeds its limit.

3.7.4 TRH = 0.04 where:

l Reduction in OTAT K setpoint required to compensate for each 1% that TRH =

1 FAH(X,Y) exceeds its limit, i

I 4

MCEl-040047 Page 18 of 19 -

Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report j

3.8 Tech Spec 3/4.5.1.1 - Accumulators

-3.8.1 Baron concentration limits during modes 1,2, & 3:

Parameter Limit Cold Leg Accumulator minimum baron concentration for 2,000 pprn LCO 3.5.1.1c Cold Leg Accumulator maximum boron concentration for 2,275 ppm LCO 3.5.1.1c Minimum Cold Leg Accumulator boron concentration 1,900 ppm required to ensure post-LOCA subcriticality 3.9 Tech Spec 3/4.5.5 - Refueling Water Storage Tank 3.9.1 Boron concentration limits during modes 1,2,3, & 4:

Parameter Limit Refueling Water Storage Tank minimum boron 2,175 ppm concentration for LCO 3.5.5b Refueling Water Storage Tank maximum boron 2,275 ppm concentration for LCO 3.5.5b

.=

l MCEI-040047 Page 19 0f 19 Revision 3 McGuire 2 Cycle 10 Core Operating Limits Report 3.10 Tech Spec 3/4.9.1 - Refueling Operations - Boron Concentration 3.10.1 Minimum boron concentrations for the filled portions of the Reactor Coolant System and refueling canal. Applicable for mode 6 with the reactor vessel head closure bolts less than fully tensioned, or with the head removed.

Parameter Linlit Refueling boron concentration for the filled portions of the 2175 ppm Reactor Coolant System and refueling canal for LCO 3.9.1.b.

3.11 Tech Spec 3/4.9.12 - Fuel Storage - Spent Fuel Storage Pool 3.11.1 Minimum boron concentration limit for the spent fuel pool. Applicable when fuel is stored in the spent fuel pool.

Parameter Lignt Spent fuel pool minimum boron concentration for LCO 2175 ppm 3.9.12.a.

Spent fuel pool minimum boron concentration for 2175 ppm surveillance 4.9.12b.

\\

i McGuire 2 Cycle 10 Core Operating Limits Report i

i i

APPENDIX

+

APPENDIX Page 1 of 140

-m

---t e

+ wg y-g-

-#v-

L APPENDIX Page 2 of 140 McGuire 2 Cylce 10 Core Operating Limits Report i

Table 1 F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 4 EFPD, THIS IS LEVEL 18 0F 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOH)

H G

F E

D C

B A

8*

.6629 *

.8611 *

.7572 *

.9146 *

.8107 *

.0011 *

.6983 *

.5666 *

  • 2.2155 + 1.8196
  • 2.0580
  • 1.677

................................. 2..*..1.8841

  • 1.8082
  • 2.1598
  • 2.6240
  • 9*

.8611 *

.7476 *

.8943 *

.8172 *

.9104 *

.7690 *.7872 *

.5194 *

  • 1. 8196
  • 2 0979
  • 1.7473
  • 1.8859
  • 1.6847 + 1.9878
  • 1.9173
  • 2.0659
  • 10 *

.7572 *

.8943 *

.7711 *

.8954

.7840 *

.8643 *

.7004 *

.4884 *

  • 2.0580
  • 1.7477
  • 2,0297 *

............................ 1. 7492.*.1.9997

  • 1.0050
  • 2.1925..*.3.0924
  • 11 *

.9146 *

.8161 *

.8921 *

.7508 *

.8439 *

.7111 *

.7047 *

.4263 *

  • 1.6772
  • 1.8864
  • 1.7554
  • 2.1037
  • 1.8227

................................................ 1666

  • 2.2227
  • 3.6488
  • 2.

12 *

.8107 *

.9104 *

.7829 *

.8410 *

.6544

.7036 ?

.5601 *

  • 1.8841
  • 1.6847.....................

61

  • 2.1229
  • 2.0100
  • 2.7052 *
  • 2.0022 + 1.82

.6011

.7679 *

.8643 *

.7111 13 *

.7036 *

.5269 *

.3889 *

  • 1.8882
  • 1.9878
  • 1.8066
  • 2.1682
  • 2.0180
  • 2.6339
  • 3.7911
  • 14 *

.69C3 *

.7861

.6994 *

.7036 *

.5601 *

.3888 *

  • 2.1598 *..... 1 9191
  • 2.1949
  • 2.2244
  • 2.7052.*.3.7911 15 *

.5666 *

.5194 *

.4884

.4252

  • 2.6240
  • 2.8700
  • 3.0971
  • 3.6507
  • M.SUB-Q AT 100% POWER, 4 EFPD, THIS IS LEVEL 17 0F 18 (LEVEL 18 : TCP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.9178

  • 1.1417 + 1.0464 1.1599
  • 1.1010
  • 1.1631 *

.9960 *

.8825 *

  • 1.7252 *

.......... 1.4413

................. 1.3722

  • 1. 4381...*.1.3491
  • 1. 5613
  • 1.7476
  • 1.5847
  • 9
  • 1.1417
  • 1.0571
  • 1.1652
  • 1.0774
  • 1.1652
  • 1.1353
  • 1.1256 *

.7508 *

  • 1.4413
  • 1.5418
  • 1.3910
  • 1.4814 1.3543
  • 1.

......**........................................ 3879

  • 1 3973
  • 2.0563 *,

10

  • 1.0464
  • 1.1620
  • 1.0346
  • 1.1492
  • 1.1053
  • 1.1599
  • 1.0335 *

.7294 *

  • 1.5847
  • 1.3951
  • 1.5724
  • 1.4101
  • 1.4715
  • 1.3898
  • 1.547

..........................................................c. 9

  • 2.1495
  • 11
  • 1.1599
  • 1.0764
  • 1.1460
  • 1.0410
  • 1.1267
  • 1.0453
  • 1.0635 *

.6415

  • 1.3722
  • 1.4628
  • 1.4140
  • 1.5719
  • 1.4415 *
  • .............................................. 1.5436
  • 1.5239
  • 2.5154 12
  • 1.1010
  • 1.1663
  • 1.1042
  • 1.1256
  • 1.0046
  • 1.0678 *.8525 *
  • 1.4381
  • 1.3523
  • 1.472

....................... 5

  • 1.4436
  • 1.5277
  • 1.4538
  • 1.8671
  • 13
  • 1.1631
  • 1.1353
  • 1.1599
  • 1.0442
  • 1.0609 *

.8150 *.5901 *

..... 91

  • 1.3886
  • 1.3908
  • 1.5448
  • 1.4528
  • 1.8744
  • 2.6366 *
  • 1.34 14 *

.9960

  • 1.1245
  • 1.0335
  • 1.0635 *

.8514 *

.5890 *

  • 1.5613
  • 1.3992
  • 1.5499
  • 1.5250
  • 1.8671...*.2.6390
  • l 15 *

.8825

  • 7497 *

.7283 *

.6405

  • 1.7476
  • 2.0610
  • 2.1517
  • 2.5185
  • M-SUB-Q a

_.__J

APPENDIX Page 3 of 140

)

McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 4 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

D B

A

......................F.......E..................C 8

  • 1.0432
  • 1.2981
  • 1.1599
  • 1.3120
  • 1.2209
  • 1.3409
  • 1.1449
  • 1.0549 *
  • 1.6372 *

.......... 1 3271. *.*1.4955

  • 1. 2632
  • 1.3494
  • 1.2176
  • 1.4133
  • 1.5178
  • 9
  • 1.2981
  • 1.1931
  • 1.3109
  • 1.1974
  • 1.3495
  • 1.3045
  • 1.3270 *

.8664 *

  • 1.3271
  • 1 4415
  • 1.2895
  • 1. 3902
  • 1.2196
  • 1.2564
  • 1.2335
  • 1.8520
  • 10
  • 1.15s9
  • 1.3066
  • 1.1363
  • 1.3045
  • 1.2627
  • 1.3462
  • 1.2113 *

.8568

  • 1.4955
  • 1.2937
  • 1.4943 *
    • .....***.................. 1.2962..*. 1. 3450
  • 1.2486.**1.3763..*.1.9021
  • 11
  • 1.3120
  • 1.1942
  • 1.3013
  • 1.1685
  • 1.3240
  • 1.2220
  • 1.2906 *

.7583 *

.................. **........... 12

  • 1.2857
  • 1.3875
  • 1.3134
  • 2.2168 *
  • 1.2632
  • 1.3994
  • 1.299/
  • 1.46 12
  • 1.2209
  • 1.3404
  • 1.2627
  • 1.3238
  • 1.20A9
  • 1.3002
  • 1.0228 *
  • 1.3494
  • 1.2180
  • 1. 3461..**1.2873
  • 1.3763
  • 1.2707
  • 1.6379
  • 13
  • 1.3409
  • 1.3045
  • 1.3462
  • 1.2209
  • 1.3002 *

.9832 *

.7036 *

  • 1.2176
  • 1.2564
  • 1.2496
  • 1.3885
  • 1.2779
  • 1.6700
  • 2.3386
  • 14
  • 1.1449
  • 1.3248
  • 1.2102
  • 1.2895
  • 1.0217 *

.7036 *

............................... 142

  • 1.6383
  • 2.3386 *
  • 1.4133
  • 1.2350
  • 1.3781
  • 1.3 15
  • 1.0549 *

.8643 *

.8557 *

.7572

  • 1.5178
  • 1.0570
  • 1. 9056
  • 2.2215
  • M-SUB-Q AT 100% POWER, 4 EFPD, THIS IS LEVEL 15 CF 18 (LEVEL 18 : TCP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8

  • 1.0999
  • 1.3923
  • 1.2220
  • 1.4084
  • 1.2938
  • 1.4426
  • 1.2284
  • 1.1545 *
  • 1.6378
  • 1.3019
  • 1.4860
  • 1.2329
  • 1.3311
  • 1.1851
  • 1. 3775
  • 1.4507
  • 9
  • 1.3923
  • 1.2659
  • 1.4030
  • 1.2788
  • 1.4694
  • 1.4030
  • 1.4523 *

.9328 *

  • 1.3019
  • 1 4306
  • 1.2625
  • 1. 3832
  • 1.1813
  • 1. 2234
  • 1.1795
  • 1.0017
  • 10
  • 1.2220
  • 1.3907
  • 1.1984
  • 1.4084
  • 1.3655 + 1.4683
  • 1.3216 *

.9307

  • 1.4860
  • 1.2665
  • 1.4854
  • 1.2590
  • 1. 3053
  • 1.1998
  • 1 3200
  • 1.8333
  • 11
  • 1.4084
  • 1.2745
  • 1.4041
  • 1.2552
  • 1.4576
  • 1.3355
  • 1.4351 *

.8268 *

  • 1.2329
  • 1.3844
  • 1.2625
  • 1.4308
  • 1.2303
  • 1.3363
  • 1.2421
  • 2.1283
  • 12
  • 1.2938
  • 1.4694
  • 1.3645
  • 1.4555
  • 1.3216
  • 1.4437
  • 1.1280 *

. 1 3311

  • 1.1798
  • 1.3067 *

............................. 20

  • 1.3280
  • 1.2183
  • 1.5659
  • 1.23 13
  • 1.4426
  • 1.4030
  • 1.4673
  • 1.3345
  • 1.4448
  • 1.0860 *

.7722 *

. 1.1851

  • 1.2242
  • 1.2005
  • 1.3374
  • 1.2176
  • 1.6045
  • 2.2569
  • 14
  • 1.2284
  • 1.4501
  • 1.3205
  • 1.4341
  • 1.1278 *

.7722

  • 1.3775
  • 1.1808
  • 1.3216
  • 1.2429
  • 1.5663
  • 2.2569
  • 15
  • 1.1545 *

.9307

.9296 *

.8257

  • 1.8063
  • 1.8361 *

............................ 2.1326

  • M-SUB-Q

1 APPENDIX Page 4 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 4 EFPD, THIS IS LEVEL 14 0F 18 (L' VEL 18 : TOP OF CORE, LEVEL 1 e BOTTOM) d F

E D

C B

A

....H........G 8* 1.1117

  • 1.4137
  • 1.2349
  • 1.4362
  • 1.3141
  • 1.4726
  • 1.2541
  • 1.1824
  • 1.7B24
  • 1.3426
  • 1.5315
  • 1.2750
  • 1.3006 *

............................**............... 1.2248

  • 1.4245
  • 1.4939
  • 9
  • 1.4137
  • 1.2820
  • 1.4266
  • 1.3023
  • 1.5112
  • 1.4351
  • 1.4919 *

.9500

  • 1.4802
  • 1.3077
  • 1.43 1.2 1.2093
  • 1.8670 *

................................ 33 *....... 178

  • 1.2646 *
  • 1.3426 *

)

10

  • 1.2349
  • 1.4212
  • 1.2145
  • 1.4416
  • 1.4009
  • 1.5101
  • 1.3591 *

.9521 *

  • 1.5315
  • 1.3120
  • 1.5444
  • 1.2952
  • 1 3381
  • 1.2280
  • 1.3517
  • 1.8911 11
  • 1.4362
  • 1.2981
  • 1.4373 + 1.2863
  • 1.5069
  • 1.3794
  • 1.4876 *

.8493 *

  • 1.2750
  • 1.4361
  • 1.2993
  • 1.4632
  • 1.2465
  • 1.3580
  • 1.2551
  • 2.1781
  • 12
  • 1.3141
  • 1.5112
  • 1.3998
  • 1.5048
  • 1.3677 1.4994
  • 1.1663 *
  • 1.3806
  • 1.2157.... 1. 3305
  • 1.2400
  • 1.3548
  • 1.2371 1.5943
  • J 13
  • 1.4726
  • 1.4341
  • 1.5090
  • 1.3784
  • 1.5005
  • 1.1245 *

.7958

  • 1.2248
  • 1.2648
  • 1.2289
  • 1.3590
  • 1.2364
  • 1.6397
  • 2.3140
  • 14
  • 1.2541
  • 1.4908
  • 1.3580
  • 1.4865
  • 1.1652 *

.7958

  • 1.3534
  • 1.2558
  • 1.5944
  • 2.316S
  • 1.4245
  • 1.2114
  • 15
  • 1.1824 *

.9478 *

.9510 *

.8482

..... 39

  • 1.8719
1. 8 92 8
  • 2.1825
  • M-Sub- ;

1.49 i

AT 100% POWER, 4 EFFD, THIS IS LEVIL 13 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTCM) i H

G F

E D

C B

A

.....................................................+..................

8

  • 1.1449
  • 1.4748
  • 1.2777
  • 1.5026
  • 1.3666
  • 1.5433
  • 1.3077
  • 1.2424 *

. 1 7345

  • 1.3433
  • 1.5494
  • 1.2901
  • 1.4090
  • 1.2402
  • 1.4508
  • 1.5084
  • l 1

9

  • 1.4748
  • 1.3291
  • 1.4909
  • 1.3602
  • 1.5915
  • 1.5048
  • 1.5722 *

.9896 *

  • 1*.3433
  • 1.4912
  • 1.3191
  • 1.4478
  • 1.2290
  • 1.2822
  • 1.2160
  • 1.9034
  • 1.5936
  • 1.4298 *

.9960

  • 10
  • 1.2777
  • 1.4855
  • 1.2595
  • 1.5133
  • 1.4694 1.2304 + 1.3577
  • 1.9135 *
  • 1.5494
  • 1.3240
  • 1.5661
  • 1.3006
  • 1 3391 11
  • 145026
  • 1.3559
  • 1.5080
  • 1.3462
  • 1.5926
  • 1.4533
  • 1.5787 *

.8809 *

  • 1.2901
  • 1.4527
  • 1.3046
  • 1.4657
  • 1.2360
  • 2.1833 *

...............................***... 1 2342

  • 1.3514
  • 12
  • 1.3666
  • 1.5904
  • 1.4603
  • 1.5904
  • 1.4416
  • 1.5904
  • 1.2295
  • 5.*. 1. 2356
  • 1.3640
  • 1.2346
  • 1.5899 *
  • 1.4090
  • 1.2292
  • 1.340 13
  • 1.5433
  • 1.5037
  • 1.5915
  • 1.4512
  • 1.5904
  • 1.1635 *.8332 *
  • 1.2402
  • 1.2829
  • 1.2311
  • 1.3526
  • 1.2339
  • 1 6554
  • 2.3361 *
  • 1.4276
  • 1.5776
  • 1.2284 *.8332
  • 14
  • 1.3077
  • 1.5701
  • 1.4509
  • 1.2176
  • 1.3588
  • 1.2367
  • 1.5910
  • 2.3386
  • 15
  • 1.2424 *

.9864 *

.9950 *

.8868

  • 1.9085
  • 1.9157
  • 2.1877
  • M-SUB-Q

APPENDIX Page 5 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operadons AT 1C0% POWEn, 4 EFFD, THIS IS LEVEL 12 0F 18 (LEVEL 18 = TOP OF CCRE, LEVEL 1 : BOTTOM)

H G

F E

D C

B A

8

  • 1.1503
  • 1.4930
  • 1.2895
  • 1.5262
  • 1.3848
  • 1.5679
  • 1.3240
  • 1.2606 *
  • 1.8145
  • 1.3947
  • 1.6116
  • 1.3423
  • 1.4732
  • 1.2933
  • 1.5175
  • 1.5774
  • 9
  • 1.4930
  • 1.3420
  • 1.5123
  • 1.3794
  • 1.6226
  • 1.5283
  • 1.6022 *

.9992 *

....*.............. 1.3643

  • 1.4988
  • 1.2667
  • 1.3376
  • 1.2621
  • 1 9969
  • 1.3947
  • 1.5535
  • 1.5069
  • 1.2734
  • 1.5422
  • 1.4951
  • 1.6279
  • 1.4555
  • 1.0078
  • 10
  • 1.2895
  • 1.6116
  • 1.3703
  • 1.6248 *
  • 1.4025
  • 1.9969 *

............................ 1.3406.*.1 3821

  • 1.2667 11
  • 1.5262
  • 1.3741
  • 1.5358
  • 1.3677
  • 1.6268
  • 1.4812
  • 1.6140 *

.8996 *

  • 1.3423
  • 1.5041
  • 1.3455
  • 1.5165
  • 1.2704 1.3939
  • 1.2704
  • 2.2578
  • 12
  • 1.3848
  • 1.6215
  • 1.4930
  • 1.6247
  • 1.4694
  • 1.6258
  • 1.2509 *

....4732

  • 1.2675
  • 1.3829
  • 1.2719
  • 1.4040
  • 1.2664
  • 1.6420
  • 1 13
  • 1.5679
  • 1.5272
  • 1.6258
  • 1.4791
  • 1.6268
  • 1.2049 *

.8439

  • 1.2933
  • 1.3384
  • 1.2682
  • 1.3956
  • 1.2664
  • 1.7058
  • 2.4158 *

......................................+....................... *

.8439

  • 14
  • 1.3240
  • 1.6001
  • 1.4533
  • 1.6129
  • 1.2499

......**...................6432

  • 2.4185 *
  • 1.2718
  • 1

............ 2638

  • 1.4035
  • 1.5175
  • 1 15
  • 1.2606 *

.9971

  • 1.0067

.8986

  • 1.5774
  • 2.0023
  • 1.9992
  • 2.2604
  • M-SUB-Q AT 100 % POWEB,

4 EFPD, THIS IS LEVEL 11 CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1. BOTTCM)

H G

F E

D C

B A

8* 1.1460

  • 1.4951
  • 1.2906
  • 1.5337
  • 1.3891
  • 1.5765
  • 1.3291
  • 1.2606 *
  • 3.9081
  • 1.4562
  • 1.6890
  • 1.4093
  • 1.5533
  • 1.3606
  • 1.60

.......................................................... 34

  • 1.6658
  • 9
  • 1.4951
  • 1.3420
  • 1.5187
  • 1.3837
  • 1.6343
  • 1.5347
  • 1.6119 *

.9982 *

  • 1.4562
  • 1 6260
  • 1.4204
  • 1.5716
  • 1 3230
  • 1.4064 1.3242 + 2.1142
  • 10
  • 1.2906
  • 1.5123
  • 1.2756
  • 1.5519
  • 1.5026
  • 1.6418
  • 1.4619
  • 1.0067
  • 1.6890
  • 1.4350
  • 1.7060
  • 1.4016
  • 1.4451
  • 1.3213 1.4603
  • 2.1055
  • 11
  • 1.5337
  • 1.3784
  • 1.5455
  • 1.3752
  • 1.6400
  • 1.4908
  • 1.626S *

.8996 *

  • 1.4093
  • 1.5703
  • 1.4070
  • 1.5865
  • 1.3229
  • 1.4566
  • 1.3219
  • 2.?673
  • 12
  • 1.3891
  • 1.6322
  • 1.4994
  • 1.6386
  • 1.4791
  • 1.6400
  • 1.2541 *
  • 1.5533
  • 1.3246
  • 1.4461
  • 1.3245
  • 1.4719
  • 1.3233
  • 1.724 2.*

13

  • 1.5765
  • 1.5337
  • 1.6397
  • 1.4887
  • 1.6418
  • 1.2081 *

.8429 *

  • 1.3606
  • 1.4073
  • 1. 3237
  • 1.4576
  • 1.3228
  • 1.7916
  • 2.5445 *

....................*.....................+................

14

  • 1.3291
  • 1.6097
  • 1.9608
  • 1.6258
  • 1.2531

.8429 *

  • 1.6034
  • 1.3261
  • 1.4703
  • 1.3227
  • 1.7
  • 2.5475 *

........................................ 257 15

  • 1.2606 *

.9950

  • 1.0057

.9986

  • 1.6650
  • 2.1203
  • 2.1075
  • 2.3724
  • M-SUB-Q

i APPENDDC Page 6 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Nomial Operations AT 100% POWER, 4 EFPD, THIS IS LEVEL 10 0F 18 (LEVEL 10 e TCP OF CORE, LEVEL 1 BOTTCM)

H G

F E

D C

B A

8* 1.1578

  • 1.5272
  • 1.3088
  • 1.5690
  • 1.4137
  • 1.6151
  • 1.3516
  • 1.2884 *
  • 1.9748
  • 1.5007
  • 1.7477 1.4587
  • 1.6172
  • 1.4147
  • 1.6764
  • 1.7313
  • 9* 1.5272
  • 1.3623 1.5540
  • 1.4116
  • 1.6761
  • 1.5679
  • 1.6547
  • 1.0132 *

............................ 1.6220

  • 1.3684 *
  • 1.5007
  • 1.6793
  • 1.4744 *..................... 16
  • 1. 3711..*.2.212.1
  • 1.46 10
  • 1.3088
  • 1.5465
  • 1.2948
  • 1.5904
  • 1.5358
  • 1.6868
  • 1.4962
  • 1.0249
  • 1.7477
  • 1.4814
  • 1.7660
  • 1.4443
  • 1.4956
  • 1.3613
  • 1.5219
  • 2.1900
  • 1.5690
  • 1.4062
  • 1.5819
  • 1.4009
  • 1.6858
  • 1.5251
  • 1.6740 *

.9146

  • 11
  • 1.4587
  • 1.6292
  • 1.4510
  • 1.6378
  • 1.3621
  • 1.5058
  • 1.3577
  • 2.4632
  • 12
  • 1.4137
  • 1.6750
  • 1.5326
  • 1.6825
  • 1.5144
  • 1.6868
  • 1.2009 *

................................ 39

  • 1 5204
  • 1.3596
  • 1.7778
  • 1.6172
  • 1.3693
  • 1.4977
  • 1.36 13
  • 1.6151
  • 1.5658
  • 1.6836
  • 1.5230
  • 1.6868
  • 1.2327 *

.8557

  • 1.3631
  • 1.5078 *
  • 1.8548
  • 2.6358 *

..................................... 1. 3587

  • 1.4147
  • 1.4626 14
  • 1.3516
  • 1.6526 + 1.4940
  • 1.6729
  • 1.2798 *

.8557 *

. 1 6764 1.3731

  • 1.5233
  • 1.3585
  • 1.7793
  • 2.6387 15
  • 1.2884
  • 1.0100
  • 1.0239 *

.9125

  • 2.1922
  • 2.4660
  • M-SUB-Q
  • 1.7313 *

)

l AT 100% POWER, 4 EFPD.

THIS IS LEVEL 9 0F 18 (LEVEL 10 : TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

1 J

8

  • 1.1363
  • 1.5026
  • 1.2063
  • 1.5465
  • 1.3923
  • 1.5936
  • 1.3302
  • 1.2649 *

....................................**... 19

  • 1.4017
  • 1.9606
  • 1.4875
  • 1.7324 1.4433
  • 1.60 1.6716
  • 1.7547
  • 9
  • 1.5026
  • 1.3388
  • 1.5305
  • 1.3891
  • 1.6558
  • 1.5444
  • 1.6333 *

.9939

  • 1.6077
  • 1.3523
  • 1.4481
  • 1.3684
  • 2.2305
  • 1.4875
  • 1.6652
  • 1.4607
  • 10
  • 1.2863
  • 1.5230
  • 1.2745
  • 1.5690
  • 1.5133
  • 1.6675
  • 1.4748
  • 1.0057 *

...... 4

  • 1.4665
  • 1.7505
  • 1. 4283
  • 1.4804
  • 1.3465
  • 1.5153
  • 2.2102
  • 1.732 11
  • 1.5465
  • 1.3837
  • 1.5615
  • 1.3827
  • 1.6675
  • 1.5050
  • 1.6547 *

.8986

  • 1.6148
  • 1.4357
  • 1.6208
  • 1.3482
  • 1.4915
  • 1.3562
  • 2.4000
  • l
  • 1.4433 i

12

  • 1.3923
  • 1.6536
  • 1.5112
  • 1.6643
  • 1.4940
  • 1.6675
  • 1.2616 *

...................... 1.3498

  • 1.5049
  • 1. 3507 1.7789
  • 1.3540
  • 1.4824 *

..... 18 *

  • 1.60 13
  • 1.5936
  • 1.5422
  • 1.6655
  • 1.5037
  • 1.6686
  • 1.2134 *

.8397 *

  • 1.4017
  • 1.4491
  • 1.3490
  • 1.4926
  • 1.3507
  • 1.8527
  • 2.6684
  • i 14
  • 1.3302
  • 1.6301
  • 1.4726
  • 1.6536
  • 1.2595 *

.8397 *

  • 1.6716
  • 1.3701
  • 1.5174
  • 1.3599
  • 1.7804
  • 2.6684
  • 15
  • 1.2649 *

.9917

  • 1.0046 *

.8964

  • 2.2373
  • 2.2124
  • 2.4836
  • M-SUB-Q b-

APPENDIX Page 7 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 4 EFFD, THIS IS LEVEL 8 0F 18 (LEVEL 18 = TOP CF CORE, LEVEL 1 = BOTTOM)

H G

E D

C B

A

......................F...................................................

8

  • 1.1428
  • 1.5283
  • 1.3002
  • 1.5733
  • 1.4094 + 1.6215
  • 1.3462
  • 1.2873 *

............................ 31.*.1 5442

  • 1.3424
  • 1. 6124
  • 1.6744 *
  • 1.4245
  • 1.6703
  • 1.38
  • 1. 8977 9
  • 1.5283
  • 1.3548
  • 1.5572
  • 1.4094
  • 1.6879
  • 1.5679
  • 1.6665
  • 1.0035 *

................. 2917

  • 1.3893
  • 1.3071.......................... 1455 *

................... 1. 3981

  • 1.5453
  • 1.4245
  • 1.6042
  • 1.
  • 2.

10

  • 1.3002
  • 1.5497
  • 1.2873
  • 1.5979
  • 1.5300
  • 1.7029
  • 1.5005
  • 1.0185 *
  • .1. 6703 *.1.4044
  • 1.6883.*.1. 3650
  • 1.4190
  • 1. 2826
  • 1.4519
  • 2.1245
  • 11
  • 1.5733
  • 1.4030
  • 1.5894
  • 1.4009
  • 1.7018
  • 1.5315
  • 1.6933 *

.9082 *

...........................**.. 562

  • 1.2833
  • 1.4255
  • 1.2901..*.2.3807 *
  • 1.3831
  • 1.5518
  • 1.3727
  • 1.5 12
  • 1.4094
  • 1.6868
  • 1.5347
  • 1.6986
  • 1.5197
  • 1.7040
  • 1.2820 *
  • 1.5442
  • 1.2932.*.1.4218
  • 1. 2856
  • 1.4376
  • 1.2833
  • 1.7015
  • 13
  • 1.6215
  • 1.5658
  • 1.6997
  • 1.5294
  • 1.7050
  • 1.2306 *

.8482 *

..... 24...................... 1.4273

  • 1.2826
  • 1.7732
  • 2.5622 *
  • 1.3910
  • 1.2848 *
  • 1.34 14
  • 1.3462
  • 1.6643
  • 1.4973
  • 1.6922
  • 1.2809 *

.8482 *

  • 1.6124
  • 1.3087
  • 1.4539
  • 1.2909
  • 1.7028
  • 2.5652
  • 15
  • 1.2873
  • 1.0014
  • 1.0174 *

.9071

  • 1.6744
  • 2.1518
  • 2.,.1265
  • 2.3913
  • M-SUB-Q AT 100% POWER, 4 EFPD, THIS IS LEVEL 7 OF 18 (LEVEL 18 = TOP CF CORE, LEVEL 1 = BOTTOM)

H C

F E

D C

B A

..........+........ **..................................................

6

  • 1.1310
  • 1.5208
  • 1.2895
  • 1.5658
  • 1.3977
  • 1.6119
  • 1.3334
  • 1.2777 *
  • 1.8491
  • 1.3737
  • 1.6

...................... 125

  • 1 3312.*.1.4897
  • 1. 2927
  • 1.5510
  • 1.6070
  • 9
  • 1.5208
  • 1.3441
  • 1.5497
  • 1.3987
  • 1.6815
  • 1.5562
  • 1.6590 *

.9917 *-

  • 1.3737
  • 1.5500
  • 1.3459
  • 1.4946
  • 1.2462
  • 1.3434
  • 1.2564
  • 2.0684
  • 10
  • 1.2895 + 1.5422
  • 1.2766
  • 1.5904
  • 1.5272
  • 1.6975
  • 1.4898
  • 1.0078 *
  • 1. 6125
  • 1 3525
  • 1.6305
  • 1.3214
  • 1.3770
  • 1.2445
  • 1.4009
  • 2.0413
  • 11
  • 1.5658
  • 1.3923
  • 1.5819
  • 1.3902
  • 1.6965
  • 1.5219
  • 1.6879 *

.8986 *

  • 1.3312
  • 1.5000
  • 1.3270
  • 1.5

............................... 150

  • 1.2459
  • 1.3801
  • 1.2488
  • 2.3029
  • 12
  • 1.3977
  • 1.6793
  • 1.5240
  • 1.6933
  • 1.5101
  • 1.6986
  • 1.2713 *
  • 1.4897 1.2476
  • 1.3787
  • 1.2481
  • 1.4135
  • 1.2563
  • 1.6572
  • 13
  • 1.6119
  • 1.5540
  • 1.6943
  • 1.5197
  • 1.6997
  • 1.2199 *

.8386 *

  • 1.2927
  • 1.3450
  • 1.2467
  • 1.3899
  • 1 2556
  • 1.7438
  • 2.4964 I

14

  • 1.3334
  • 1.E558
  • 1.4876
  • 1.6858
  • 1.2702 *

.8375

  • l
  • 1.5510.*. 1.2578
  • 1.4036
  • 1.2503
  • 1. 6584
  • 2.4992
  • 15
  • 1.2777 *

.9896

  • 1.0067 *

.8964

  • 1.6070
  • 2.0723
  • 2.0450
  • 2.3053
  • M-SUB-Q

APPENDIX Page 8 of 140 McGuire 2 Cylce 10 Core O serating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 4 EFPD, THIS IS LEVEL 6 OF 18 (LEVEL 10 v TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8

  • 1.1031
  • 1.4855
  • 1.2595
  • 1.5294
  • 1.3645
  • 1.5722
  • 1.2991
  • 1.2402
  • 1.*. 1.*.5724*.1 3000
  • 1.4545
  • 1.2633
  • 1.5192
  • 1.5007..*
  • 1.7966
  • 1.338 9
  • 1.4855
  • 1.3141
  • 1.5144
  • 1.3634
  • 1.6408
  • 1.5155
  • 1.6161 *

.9628 *

.................. 1. 3133

  • 1.4602
  • 1.2163
  • 1.3140
  • 1.2293
  • 2.0339 *
  • 1 3381
  • 1.5106 *
  • 1.6568
  • 1.4501 *

.9768

  • 10
  • 1.2595
  • 1.5069
  • 1.2466
  • 1.5519
  • 1.4887
  • 1.5724
  • 1.3196
  • 1.5918 *

.........**................. 1.2891

  • 1.3445
  • 1.2120
  • 1.3707
  • 2 0094 1.3580
  • 1.5433
  • 1.3570
  • 1.6558
  • 1.4833
  • 1.6440 *

.8707

  • 11 1.5294
  • 1.3535
  • 1.2188
  • 2.2622 *
  • 1. 3000
  • 1.4661
  • 1.2945
  • 1.4747
  • 1.2127
  • 12
  • 1.3645
  • 1.6397 1.4855
  • 1.6526
  • 1.4716
  • 1.6558 1.2349 *
  • 1.4545
  • 1.2176
  • 1.3462
  • 1.2154
  • 1.3720
  • 1.2192
  • 1.6200
  • 13
  • 1.5722
  • 1.5144
  • 1.6526
  • 1.4812
  • 1.6568
  • 1 :856 *

.6118 *

  • 1.2633
  • 1.3156
  • 1.2141
  • 1 3544
  • 1.2186 *

-72

  • 2.4487
  • _.6140
  • 1.4480
  • 1.6418
  • 1.2327 *

.8107

  • 14
  • 1.2991
  • .................... 3725
  • 1.2195
  • 1.6220
  • 2.4488
  • 1.5192 + 1.2307
  • 1.................................

15

  • 1.2402 *

.9596 *

.9757 *

.8697

........***.......... 0113.*.2 2668

  • M-SUB-Q
  • 1.5807
  • 2.0395
  • 2.

AT 10 0% PCWER, 4 EFFD, THIS IS LEVEL 5 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

H O

F E

D C

B A

8

  • 1.1010
  • 1.4973
  • 1.2627
  • 1.5369 + 1.3645
  • 1.5765
  • 1.2927
  • 1.2391 *
  • 1.7083
  • 1.2623
  • 1.4919
  • 1.2312
  • 1.3846
  • 1.1984 1.4542
  • 1.5099
  • 9
  • 1.4973
  • 1.3184
  • 1.5251
  • 1.3655
  • 1.6461
  • 1.5133
  • 1.6194

.9553 *

................... 1 2409

  • 1. 3872
  • 1. 1537
  • 1.2515
  • 1. 1678
  • 1. 9572..*.

1.2623

  • 1.4307
  • 1.5176
  • 1.2477
  • 1.5562
  • 1.4865
  • 1.6600
  • 1.4480 *

.9725

  • 10
  • 1.2627
  • 1. 4919
  • 1.2472
  • 1. 5133
  • 1.2216
  • 1.2792.*. 1.1483
  • 1.3072..*.1. 9281
  • 11
  • 1.5369
  • 1.3591
  • 1.5476
  • 1.3548
  • 1.6590
  • 1.4801
  • 1.6472 *

.8632 *

  • 1.2312
  • 1.3934
  • 1.2271
  • 1.4031
  • 1.1494
  • 1.2874
  • 1.1560
  • 2. 1759
  • 12
  • 1.3645
  • 1.6440
  • 1.4833
  • 1.6558
  • 1.4694
  • 1.6590
  • 1.2284 *
  • 1.3846
  • 1.1549
  • 1.2007
  • 1.1519
  • 1.30 1.5471 *

........................................ 11

  • 1.1537 13
  • 1.5765
  • 1.5123
  • 1.6568
  • 1.4780
  • 1.6600
  • 1.1781 *.8032 *
  • 1.1984 1.2529
  • 1.1506
  • 1.2689
  • 1.153

.......................................... 1.*.1.6201

  • 2.3528
  • 14
  • 1.2927
  • 1.6172
  • 1.445?
  • 1.6451
  • 1.2274 *

.0022

  • 1.4542
  • 1.1696
  • 1.3088
  • 1.1572
  • 1.5482
  • 2.3553
  • 15
  • 1.2391 *

.9532 *

.9703 *

.8622

  • 1 5099
  • 1.9609
  • 1.9298
  • 2.1783
  • M-SUB-Q

N H

APPENDDC Page 9 of 140

' McGuire 2 Cylce 10 Core Operating Limits Report -

Table 1 (cont.) '

L F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations J

AT.100% POWER, 4 EFPD,- THIS IS LEVEL 4 OF 18 l

(LEVEL id = TOi 0F CORE, LEVEL 1 m BOTTOM)

....H......**C.......F..........E.......D.........C.........B-.........A 8

  • 1.0678
  • 1.4491
  • 1.2752
  • 1.4833
  • 1.3184
  • 1.5155
  • 1.2381-* 1.1760 *
  • 1. 6813.*. 1. 2449..*.1. 4683
  • 1. 2181..*.1. 367.9
  • 1. 1899
  • 1. 4507..*.1 5207 *-

9

  • 1.4491
  • 1.2788
  • 1.4758
  • 1.3163
  • 1.5787 *.1.4501
  • 1.5465 *.9093 *
  • 1 2449
  • 1. 4074
  • 1. 2242.*. 1.3730.*.1 1476.*.1. 2456
  • 1. 1676..*. 1. 9660
  • 10
  • 1.2252
  • 1.4673
  • 1.2001
  • 1.4962
  • 1.4244
  • 1.T983
  • 1.3816'*

.9232 *

  • 1. 4683..*.1. 2310
  • 1. 4911..*.1 2100..*. 1. 2716.*.1. 1434
  • 1 3061..*.1. 9.401.*

11

  • 1.4833
  • 1.3109
  • 1.4887
  • 1.3045
  • 1.5872
  • 1.4148
  • 1.5658 *

.8193 *

  • 1.2181'* 1.3791.*.1. 2154
  • 1. 3877
  • 1.1441
  • 1.2826
  • 1. 1583...*.2 1890
  • 12
  • 1.3184
  • 1.5765
  • 1.4212
  • 1.5840
  • 1.4041
  • 1.5819
  • 1.1663 *
  • 1 3679
  • 1 1488
  • 1 2730
  • 1.1464
  • 1. 2932..*.1. 1505..*. 1. 5518
  • 13
  • 1.5155
  • 1.4491 + 1.5851
  • 1.4126
  • 1.5819
  • 1.1192 *.7604 *

.... 899

  • 1 2471
  • 1 1458
  • 1.2841
  • 1.149.9
  • 1.6205
  • 2.3678 *
  • 1;1.................................

14

  • 1.2381
  • 1.5444
  • 1.3794
  • 1.5637
  • 1.1652 *.7593 *
  • 1. 4507..... 1. 1695
  • 1. 3085
  • 1. 1590
  • 1. 5540..*.2 3700
  • 15
  • 1.1760 *

.9071 *.9221 *.8182

.[

  • 1. 5207
  • 1.9713
  • 1.9418
  • 2 1934.* M-SUB-Q

~

3 AT 100% POWER, 4 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTo"t

....H.........G.........F.........E.........D.........C B

A 8

  • 1.0507
  • 1.4266
  • 1.2092
  • 1.4555
  • 1.2938
  • 1.4726
  • 1.1999
  • 1.1171 *

...... 2

  • 1 2190
  • 1 4339
  • 1.1964
  • 1.3430
  • 1.1798
  • 1.4555
  • 1 5451 *
  • 1.647 4

9

  • 1.4266
  • 1.2584
  • 1.4555
  • 1.2948
  • 1.5294
  • 1.4030
  • 144833 *. 4675 *
  • 1.2190
  • 1. 3775
  • 1 1964
  • 1. 3447
  • 1 1406.*. 1.2409.*. 1. 1733.*.1.,9.!*
  • 10
  • 1.2092
  • 1.4469
  • 1.1931
  • 1.4651
  • 1.3805
  • 1.5305
  • 1 3248 *.8782
  • 9..*. 1.2029
  • 1. 4556
  • 1.1900
  • 1. 2622
  • 1.1406
  • 1. 3124
  • 1. 9656 *
  • 1.433 11
  • 1.4555
  • 1.2884
  • 1.4576
  • 1.2745
  • 1.5305
  • 1.3602
  • 1.4887 *

.7743 *

... 1.964.*.1. 3512.*.1. 1957

  • 1 3672..*. 1. 1418..*.1 2820
  • 1. 1714.*. 2. 2323 *
  • 1.

12

  • 1.2938
  • 1.5272
  • 1.3784
  • 1.5272
  • 1.3527
  • 1.5144
  • 1.1074 *
  • 1 3430..*. 1.1424
  • 1. 2636.*.1. 1436
  • 1. 2909
  • 1. 1543
  • 1. 5716
  • 13
  • 1.4726
  • 1.4009
  • 1.5272
  • 1.3500
  • 1.5144
  • 1.0646 *.7186 *
  • 1 1798
  • 1 2422..*.1. 1418.*. 1.2842
  • 1.1537
  • 1. 6370
  • 2 4105
  • 14
  • 1.1899
  • 1.4812
  • 1.3227.* 1.4865
  • 1.1063 *.7186 *
  • 1. 4555..*. 1. 1752
  • 1. 3140
  • 1. 1727
  • 1.5729
  • 2.4109
  • 15
  • 1.1171 *.8654 *.8771 *.7733
  • 1.5451...*.1 9940..*.1. 9692..*. 2.2348
  • M-SUB-Q 6

4 y

=

r

-r

- + - - -

m

,o.-+-w-e-w--..-

s

--r-

APPENDIX Page 10 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 4 EFPD, THIS IS LEVEL 2 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

........................................D.........C........B.........A 8*

.9778

  • 1.3109
  • 1.1235
  • 1.3420
  • 1.1995
  • 1.3120
  • 1.0507 *

.9489 *

. 1.7237

  • 1. 2909
  • 1.5030 *

......... 42

  • 1. 4106
  • 1.2005
  • 1.6045
  • 1 7719
  • 1.26 9
  • 1.3109
  • 1.1599
  • 1.3484
  • 1.210'
  • 1.3730
  • 1.2563
  • 1.2991 *

.7615 *

  • 1.2909 *

.......... 1. 4562

  • 1.2569
  • 1. 3:.2.***.. 2365
  • 1.3475
  • 1.3029
  • 2 2064 *

)

  • 1 10
  • 1.1235
  • 1.3409
  • 1.1171
  • 1.3409
  • 1.2488
  • 1.3655
  • 1.1642 *

.7604

  • 1.5030
  • 1.263 4..*.1. 5132.*. 1.2648
  • 1.3558
  • 1.2420
  • 1.4522
  • 2 2151 11
  • 1.3420
  • 1.2049
  • 1.3345
  • 1.1749
  • 1.3698
  • 1.2134
  • 1.2713 *

.6651

.... 642...*.1.4052

  • 1. 2706
  • 1.4419
  • 1.2413
  • 1.3971
  • 1.3335
  • 2. 5308 *
  • 1.2 12
  • 1.1995
  • 1.3709
  • 1.2477
  • 1.3666
  • 1.2113
  • 1.3227 *

.9575 *

.... 106

  • 1.2385
  • 1.3568
  • 1.2441
  • 1.4006
  • 1.2839
  • 1.7676 *
  • 1.4 13
  • 1.3120
  • 1.2552
  • 1.3645
  • 1.2113
  • 1.3239 *

.9339 *.6223 *

  • 1.2005
  • 1.3484 *

................... 1 2434

  • 1.3968
  • 1 2832
  • 1.8128
  • 2.7110
  • 14
  • 1.0507
  • 1.2970
  • 1.1620
  • 1.2691 *

.9575 *.6212 *

.......... 1. 3051..*.1. 4550

  • 1. 3351.*.1.7690
  • 2 7144 *
  • 1.6045
  • 15 *

.9489 *

.7604 *

.7593 *

.6640

  • 1.7719..*.2.2128
  • 2.2173.*.2.5363
  • M-SUB-Q AT 100% POWER.

4 EFPD, THIS IS LEVEL 1 CF 18 (LEVEL 18 = TOP CF CCRE, LEVEL 1 = BOTTOM)

H G

E D

C B

A

......................F...................................................

8*

.7111

.9371 *

.7700 *

.9875 *.8354 *

.8514 *

.6994 *

.5698 *

  • 2.3335
  • 1. 7726
  • 2.1556
  • 1 6846
  • 1.9902
  • 1.9512..*.2.3707
  • 2. 9001 *

.'9639 *

.8654 *

.9950 *

.8129 *.8525 *.5012

  • 9*

.9371 *

.7797 *

  • 1.7726 *

.......... 2 1284 *

................. 208

  • 1.6717
  • 2.0453
  • 1.9475
  • 3.2953
  • 1.725/
  • 1.9 10
  • 7700 *

.9607 *

.7150 *.9821 *.8418 *.9650 *.7390 *

.4819 *

  • 2.1556
  • 1.7307
  • 2.

............**.. 1163

  • 1.6936
  • 1.9741
  • 1.7239
  • 2.2472
  • 3.1336
  • 11 *

.9875 *.8622 *

.5768 *.8022 *

.9714 *

.7947 *.7915 *.4220 *

  • 1. 6846
  • 1 9293 '. 1.7028
  • 2.0724
  • 1. 7133
  • 2.0920
  • 2.0978
  • 3.9159
  • 12 *

.8354 *

.99.8 *

.8397 *

.9682 *

.0011 *

.8643 *.6051

  • 1.9902
  • 1.f/67
  • 1.98
  • .............,......... 12
  • 1.7198
  • 2. 0801
  • 1.9271
  • 2.7420
  • 13 *

.8514 *

.8118 *

.9628 *

.7936 *

.8643 *

.6137 *.3995 *

  • 1.s512
  • 2.0472
  • 1.7266
  • 2.0958 *

..................................... 1.9256

  • 2.7052.*.4.1507
  • 14 *

.6994 *

.8514 *

.7379 *

.7915 *

.6051 *

.3995 *

  • 2.3707
  • 1 9494
  • 2. 2498
  • 2.0998
  • 2.7455
  • 4.1507
  • 15 *

.5698 *

.5012 *

.4009 *.4220

  • 2.9001 *.3.3003
  • 3.4390
  • 3.9220
  • M-SUB-Q

APPENDIX Page 11 of 140 McGuire 2 Cylce 10 Core Operating Limits Report liable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 200 EFPD, THIS IS LEVEL 18 0F 18 (LEVEL 18 = TOP OF CCRE, LEVEL 1 = BOTTOM)

H G

E D

C B

A

......................F...................................................

8*

.7058 *

.9275 *

.8172 *

.9650 *

.8579 *

.8343 *

.7240 *

.6190 *

  • 2.0674

.........................**.............. 13

  • 1.8564
  • 2.1268
  • 2.4625 ** 1.7298
  • 1.9567
  • 1.6259
  • 1.82..............................

9*

.9275 *

.8118 *

.9564 *

.8697 *

.9575 *

.8107 *

.8300 *

.5516 *

  • 1.7298 *

.......... 1 9711

  • 1. 6674

............... 1. 6389

  • 1.9417............... 1. 8701.*.2. 7645 *
  • 1.8084
  • 10 *

.8172

.9553 *

.8268 *

.9564 *

.8386 *

.9136 *

.7315 *

.5323 *

  • 1.9567
  • 1.6688
  • 1.9344
  • 1.6716
  • 1.9090
  • 1.7508
  • 2.1563
  • 2.9113
  • 11 *

.9650 *

.8697

.9543 *

.8215 *

.9114 *

.7690

  • 7668 *

.4691

  • 1.6259
  • 1.8085
  • 1.6771
  • 1.9730
  • 1.7302
  • 2.0532
  • 2.095
  • ............................................................ 4
  • 3.3997
  • 12 *

.8579 *

.9575 *

.8386 *

.9104 *

.7079 *

.7743 *

.6083 *

  • 1.8213
  • 1. 6389
  • 1.9125
  • 1. 7318
  • 1.9589
  • 1.8776
  • 2.5591
  • 13 *

.8343 *

.0097 *

.9136 *

.7679 *

.7743 *

.5816 *

.4445

  • 1.8564
  • 1.9417
  • 1.7509
  • 2.0551
  • 1.8760
  • 2.4458
  • 3.4076 *

.7240

.8300 *

.7315

  • 7658 *

.6083 *

.4445

  • 14
  • 2.1268
  • 1.0718
  • 2.1586
  • 2.0974
  • 2.5591
  • 3.4076
  • 15 *

.6190 *

.5516 *

.5323 *

.4680

  • 2.4625
  • 2.7683
  • 2.9113
  • 3.3997
  • M-SUB-Q AT 100% POWER, 200 EFPD, THIS IS LEVEL 17 OF 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.9768

  • 1.2188
  • 1.1021
  • 1.2349
  • 1.1331
  • 1.1438 *

.9853 *

.9029

  • l
  • 1.6554
  • 1.3745
  • 1.5300
  • 1.3192
  • 1.4260
  • 1. 4017
  • 1.6136
  • 1..,7433
  • 9
  • 1.2188
  • 1.1117 1.2413
  • 1.1278
  • 1.2274
  • 1.1353
  • 1.1385 *

.7497 *

  • 1.3745
  • 1.4949
  • 1.3296
  • 1.443

................................. 1...*.1 3 2 6 9

  • 1. 4 3 2 9
  • 1 413 4
  • 2.10 7 0
  • 10
  • 1.1021
  • 1.2381
  • 1.1021
  • 1.2263
  • 1.1449
  • 1.2113
  • 1.0410 *

.7518 *

  • 1.5300
  • 1.3322
  • 1.5021
  • 1.3478 *
  • 1.5720
  • 2.1312 *

..................................... 1.4514

  • 1.3603 11 1.2349 + 1.1267 1.2242
  • 1.1160
  • 1.2049
  • 1.0796
  • 1.0956 *

.6597 *

  • 1.3192
  • 1.4441
  • 1.3496
  • 1.5025
  • 1.3678
  • 1.

................................................ 5250

  • 1.5216
  • 2 5013
  • 12
  • 1.1331
  • 1.2252
  • 1.1438
  • 1.2027
  • 1.0560
  • 1.1353 *

.8675 *

  • 1.4260
  • 1.3260
  • 1.4534
  • 1.3687
  • 1.4872
  • 1.3985
  • 1.8752
  • j 13
  • 1.1438
  • 1.1353
  • 1.2102
  • 1.0785
  • 1.1353 *

.8493 *.6383

  • I

................... 1. 3603

  • 1.5262
  • 1. 3976
  • 1.8439
  • 2.4987
  • l 1.4017
  • 1.4329
  • 14 *

.9853

  • 1.1374
  • 1.0410
  • 1.0956 *

.8675 *

.6363 *

  • 1.6136
  • 1.4143
  • 1.5732
  • 1.5217
  • 1.8753
  • 2.4987
  • 15 *

.9029

  • 7476 *

.7508 *

.6587

..... 33 *

  • 1.74 2.1111
  • 2.1332
  • 2.5016
  • M-SUB-Q

r APPENDIX Page 12 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 200 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

.....................................B.........A H

C F

E D

C 8

  • 1.1021
  • 1.3805
  • 1.2167
  • 1.3848
  • 1.2434
  • 1.2788
  • 1.0881
  • 1.0314 *

.......... 1. 2654 *..................................... ***.......... 1 5777 *

  • 1.5732
  • 1.4458
  • 1.2184
  • 1.3453
  • 1.2970
  • 1.5105
  • 9
  • 1.3805
  • 1.2456
  • 1.3944
  • 1.2424
  • 1.3902
  • 1.2745
  • 1.3023 *.8268 *
  • 1.2654
  • 1.4016
  • 1.2263
  • 1.3611
  • 1.2205
  • 1.

................................................ 3242

  • 1.2827
  • 1. 9718
  • 10
  • 1.2167
  • 1.3912
  • 1.2124
  • 1.3880
  • 1.2820
  • 1.3816
  • 1.1781 *

.8472 *

  • 1.4458
  • 1. 2299
  • 1.4175
  • 1.2358
  • 1.3464................ 2365
  • 1.4390
  • 1.9570 *
  • 1 1.3848
  • 1.2402
  • 1.3848
  • 1.2434
  • 1.3784 1.2306
  • 1.2681 *

.7454 11 *

..................................... 1. 2449

  • 1 3992..*.1. 3664
  • 1.2104
  • 1.3620
  • 1.2380
  • 1.4016 *
  • 2.2918
  • 12
  • 1.2434
  • 1.3869
  • 1.2798
  • 1.3762
  • 1.2338
  • 1.3377 *

.9939 *

  • 1.3453
  • 1.2198
  • 1.3481
  • 1.2464
  • 1.3723
  • 1.2648
  • 1.7124
  • 13
  • 1.2788
  • 1.2745
  • 1.3816
  • 1.2295
  • 1.3377

.9853 *.7315

  • 1.6963
  • 2.2926 *

. 1. 2970

  • 1.3249
  • 1.2365
  • 1.4001..*.1.2640
  • 14
  • 1.0881
  • 1.3013
  • 1.1781
  • 1.2681 *

.9939 *

.7315 *

.............. 34..*.1.4400

  • 1.3664
  • 1.7137
  • 2.2949
  • 1.5105
  • 1.28 15
  • 1.0314 *

.8257 *

.8472 *

.7454

  • 1.5777
  • 1.9755
  • 1.9589
  • 2.2943
  • M-SUB-Q AT 100% POWER, 200 EFPD, TilIS IS LEVEL 15 0F 18 (LEVEL 18 = TCP CF CORE, LEVEL 1. BOTTOM)

......................F H

G E

D C

B A

8

  • 1.1535
  • 1.4705
  • 1.2713
  • 1.4716
  • 1.2991
  • 1.3398
  • 1.1310
  • 1.0871 *
  • 1.5769
  • 1.2410
  • 1.4365
  • 1.

.............................. 1940

  • 1.3402
  • 1.2866
  • 1.5098
  • 1 5542
  • 9
  • 1.4705
  • 1.3088
  • 1.4791
  • 1.3045
  • 1.4791 1.3420
  • 1.3859 *

.8589 *

  • 1.2410
  • 1.3936
  • 1.2042
  • 1. 3531.*.1. 1927 1.3089
  • 1.2562 *

........................ 1. 9746

  • 10
  • 1.2713
  • 1.4758
  • 1.2691
  • 1.4769
  • 1.3537 1.4726
  • 1.2445 *

.8900

  • 1.2077
  • 1. 4365
  • 1.4107................. 1.3278
  • 1.2070
  • 1.4164
  • 1. 9371..*
  • 1.2090
  • 11
  • 1.4716
  • 1.3013
  • 1.4737
  • 1.3120
  • 1.4833
  • 1.3077
  • 1.3570 *

.7840 *

  • 1.1940
  • 1.3539
  • 1.2111
  • 1.3839
  • 1.2105
  • 1.3764 *

....................................................... 1.3305

  • 2.2685
  • 12
  • 1.2991
  • 1.4758
  • 1.3516
  • 1.4812
  • 1.3152
  • 1.4394
  • 1.0560 *
  • 1.3402
  • 1.1933 *
  • 3303
  • 1.2126
  • 1.3524
  • 1.2348
  • 1.6903
  • 13
  • 1.3398
  • 1.3420
  • 1.4716
  • 1.3066
  • 1.4394
  • 1.0507 *

.7754 *

  • 1.2866
  • 1.3009
  • 1.2077
  • 1.3773
  • 1.2347 1.6762
  • 2.2760
  • 14
  • 1.1310
  • 1.3848
  • 1.2434
  • 1.3559
  • 1.0549 *

.7754 *

  • 1.5098
  • 1.2569
  • 1.4174
  • 1.3313
  • 1.6903
  • 2.27b5
  • 15
  • 1.0871 *

.8579 *

.8809 *

.7829

  • 1.5542
  • 1.9784
  • 1.9388
  • 2.2709
  • M-SUB-Q 1

1

APPENDLX Page 13 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1?able 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin)- Normal Operations AT 100% POWER, 200 EFPD, THIS IS LEVEL 14 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 BOTTOM)

H G

F E

D C

B A

8

  • 1.1556 + 1.4791
  • 1.2734
  • 1.4801
  • 1.3002
  • 1.3388
  • 1.1256
  • 1.0839
  • 1.6367
  • 1.2798
  • 1.4810
  • 1.2422
  • 1.4022
  • 1.3487
  • 1.5871
  • 1.6315
  • 9* 1.4791
  • 1.3141
  • 1.4876
  • 1.3109
  • 1.4908
  • 1.3452
  • 1.3912 *

.8525

  • 1.2798
  • 1.4412
  • 1.2530
  • 1.4123
  • 1.2394
  • 1 3658
  • 1.3103
  • 2.0802
  • 10
  • 1.2734
  • 1.4844
  • 1.2734
  • 1.4887
  • 1.3612
  • 1.4844
  • 1.2477 *

.8857

  • 1.4810
  • 1.2567
  • 1.4711
  • 1.2538
  • 1.3759
  • 1.2531
  • 1.4763
  • 2.0333
  • 1.3173
  • 1.3655 *

.7829

  • 11
  • 1.4801
  • 1.3066
  • 1.4855
  • 1.3216
  • 1.4994 1.2422
  • 1.4133
  • 1.2567 *

........................................... 1.4214

  • 1.3691
  • 2.3672
  • 1.4252
  • 1.2473
  • 12
  • 1.3002
  • 1.4876
  • 1.3591
  • 1.4973
  • 1.3280
  • 1.4533
  • 1.0603 *
  • 1.2791
  • 1.7571
  • 1.4022
  • 1.2394
  • 1. 3786
  • 1.2489
  • 1.4011 1.3388
  • 1.3452
  • 1.4833
  • 1.3163
  • 1.4544
  • 1.0560 *

.7765

  • 13 1.3487
  • 1.3659
  • 1.2538
  • 1.4226
  • 1.2788
  • 1.7497
  • 2.3842
  • 14
  • 1.1256
  • 1.3912
  • 1.2466
  • 1.3655
  • 1.0592 *

.7765

  • 1.5871
  • 1.3118
  • 1.4773
  • 1.3691
  • 1.7501
  • 2.3861
  • 15
  • 1.0839 *

.8514 *

.8857 *

.7818

  • 2.0843
  • 2.0352
  • 2.3697
  • M-SUB-Q AT 100% POWER, 200 EFPD, THIS IS LEVEL 13 OF 18 (LEVEL 18 TOP OF CCRE, LEVEL 1 = BOTTOM)

..........D........C E

B A

H G

F 1.1824

  • 1.5315
  • 1.3055
  • 1.5326
  • 1.3334
  • 1.3752
  • 1.1481
  • 1.1128
  • 8
  • 1.6613
  • 1.2786
  • 1.4991
  • 1.2603
  • 1.4395
  • 1.3822
  • 1.6379
  • 1.6717 9* 1.5315
  • 1.3495
  • 1.5412
  • 1.3484
  • 1.5433
  • 1.3816
  • 1.4373 *

.8675

  • 1.2786
  • 1.4523
  • 1.2652
  • 1.4409
  • 1.2553
  • 1.3945
  • 1.3335
  • 2.1500
  • 4..................................................................

10

  • 1.3055
  • 1.5300
  • 1.3077 1.5412
  • 1.4030
  • 1.5380
  • 1.2820 *

.9071 *

  • 1.4991
  • 1.2689
  • 1.4945
  • 1.2633
  • 1.3894
  • 1.2643
  • 1.4998
  • 2.0845
  • 11
  • 1.5326
  • 1.3441
  • 1,5380
  • 1.3612
  • 1.5572
  • 1.3570
  • 1.4126 *

.7990 *

......... 342

  • 1.2503
  • 1.4325
  • 1.J696
  • 2.4081 1 2603 + 1.4447.................

2660 *

  • 1 1.4 12
  • 1.3334
  • 1.5401
  • 1.3998
  • 1.5551
  • 1.3687
  • 1.5069
  • 1.0861
  • 1.4395
  • 1.2560
  • 1.3921
  • 1.2518
  • 1.4242
  • 1.2918
  • 1.7811
  • 13
  • 1.3752
  • 1.3005
  • 1.5358
  • 1.3559
  • 1.5069
  • 1.0960 *

.7947

  • 1.3822
  • 1.3951
  • 1.2648
  • 1.4335
  • 1.2918
  • 1.7886
  • 2.4353
  • 1.4362
  • 1.2809
  • 1.4126
  • 1.0881 *

.7947 14

  • 1.1481
  • 2.4380
  • 1.6379
  • 1.3343
  • 1.5009
  • 1.3704
  • 1.7811

.9061 *

.7990

  • 1.1128 *

.8664 2.1543

  • 2.0865
  • 2.4081
  • M-SUB-Q 1.6717

i i

I APPENDDC Page 14 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1hable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations J

AT 100% POWER, 200 EFPD, THIS IS LEVEL 12 0F 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 s BOTTOH)

......................F.........E.......D.......C H

G B

A 8

  • 1.1835
  • 1.5422
  • 1.3098
  • 1.5433
  • 1.3366
  • 1.3773
  • 1.1449
  • 1.1106 *
  • 1 7355
  • 1. 3252
  • 1.5616
  • 1.3065..*. 1.5077
  • 1.4492
  • 1.7267
  • 1. 7587
  • 9
  • 1.5422
  • 1.3548
  • 1.5530
  • 1.3548
  • 1.5540
  • 1.3848
  • 1.4437

.8643 *

  • 1.3252
  • 1.5111
  • 1.3085..*.1.4948
  • 1 3018
  • 1. 4517
  • 1.3849
  • 2. 2681.*

10

  • 1.3098
  • 1.5487
  • 1.3120
  • 1.5530
  • 1.4094
  • 1.5476
  • 1.2841 *

.9039 *

  • 1.56

..... 16

  • 1. 3122
  • 1.5510
  • 1. 3054
  • 1. 4402
  • 1.3076.*.1 5582
  • 2.1891.*

11

  • 1.5433
  • 1.3505
  • 1.5487
  • 1.3687
  • 1.5701
  • 1.3623
  • 1.4191 *

.7968 *

  • 1.3085
  • 1.4999
  • 1 3085
  • 1 4887
  • 1.2904
  • 1.4859
  • 1.4207
  • 2.5038
  • 12
  • 1.3366
  • 1.5508
  • 1.4052
  • 1.5679
  • 1.3752
  • 1.5165
  • 1.0892 *
  • 1.5077
  • 1.3021...*.1. 4431
  • 1. 2920
  • 1. 4730
  • 1.3335
  • 1. 8504
  • 13
  • 1.3773
  • 1.3837
  • 1.5465
  • 1.3612
  • 1.5165
  • 1.0860 *

.7925 *

  • 1.4492
  • 1.4517

................... 1. 3084

  • 1. 4869
  • 1. 3335
  • 1.8551
  • 2.5306
  • 14
  • 1.1449
  • 1.4426
  • 1.2831
  • 1.4191
  • 1.0892 *.7925 *
  • 1.7267
  • 1.3858
  • 1.559 3.*. 1.4216.*.1.8504
  • 1.5334
  • 15
  • 1.1106 *

.8622 *

.9029 *

.7968

  • 1.7587
  • 2.2726
  • 2.1891.*.2.5049...* M-SUB-Q l

AT 100% POWER, 200 EFPD, THIS IS LEVEL 11 0F 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 = BOTTOM)

H D

C B

A

.............G.........F.........E..........................................

8

  • 1.1781
  • 1.5422
  • 1.3066
  • 1.5422
  • 1.3323
  • 1.3720
  • 1.1363
  • 1.1010 *
  • 1.8253
  • 1.3841..*.1 6356
  • 1.3717
  • 1. 5883
  • 1.5297
  • 1.8279
  • 1.8607 9 + 1.5422
  • 1.3516
  • 1.5530
  • 1.3537
  • 1.5530
  • 1.3784
  • 1.4384

.8557

  • 1.3841
  • 1.5839
  • 1.3678
  • 1.5671
  • 1.3630
  • 1.5262
  • 1.4528
  • 2.4020
  • 10
  • 1.3066
  • 1.5487
  • 1.3098
  • 1.5519
  • 1.4062
  • 1.5465
  • 1.2777 *

.8954 *

  • 1 6356
  • 1.3717

...................................................... 365

  • 2.3088 *
  • 1.6268
  • 1.3652
  • 1.5089
  • 1.3676
  • 1.6 11
  • 1.5422
  • 1.3495
  • 1.5487
  • 1.3666
  • 1.5701 1.3500
  • 1.4148 *

.7893

  • i
  • 1.3717
  • 1.5723
  • 1.3683 *

............................ 1.5582

  • 1.3505
  • 1.5508
  • 1.4833
  • 2.6277
  • 12
  • 1.3323
  • 1.5497
  • 1.4019
  • 1.5679
  • 1.3720
  • 1.5133
  • 1.0817
  • 1 5883
  • 1.3642
  • 1.5121..*. 1.3530
  • 1. 5476
  • 1.3978
  • 1.9470
  • 13
  • 1.3720
  • 1.3773
  • 1.5444
  • 1.3570
  • 1.5144
  • 1.0774 *

.7850 *

................................................... 1.*.2.6716 *

  • 1.5297
  • 1.5268
  • 1.3608
  • 1.5599
  • 1.3978
  • 1.953 14
  • 1.1363
  • 1.4373
  • 1.2766
  • 1.4148
  • 1.0817 *

.7850 *

  • 1.8279
  • 1.4537
  • 1.6377
  • 1.4837 *

......................................1 9488

  • 2.6716
  • 15
  • 1.1010 *

.8536

.8943 *

.7803

  • 1.0607
  • 2.4073
  • 2.3088
  • 2.6300
  • M-SUB-Q

APPENDIX Page 15 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin)'- Normal Operations AT 100% POWER, 200 EFPD, THIS IS LEVEL 10 OF 18 (LEVEL 18 : TOP OF CORE, LEVEL 1 = BOTTOM)

..........................................................B........A H

G F

E D

C 8

  • 1.1931
  • 1.5787
  • 1.3270
  • 1.5797
  • 1.3527 ' 1.3955
  • 1.1481 ' 1.1192 *

...................'.........'............ 568

  • 1.5924..*. 1.9094
  • 1. 9301.*
  • 1.9007
  • 1.4276 1.7030 1.4182
  • 1.6.........

9

  • 1.5787
  • 1.3741
  • 1.5904
  • 1.3773
  • 1.5883
  • 1.3998
  • 1.4683 *

.8643 *

. 1 4276

  • 1.6459
  • 1.4123
  • 1.6301.*.1.4079
  • 1.5885.*. 1. 5022..*.2 5066
  • 10
  • 1.3270
  • 1.5862
  • 1.3302
  • 1.5872
  • 1.4309
  • 1.5808
  • 1.2981 *

.9071 *

........................................ 664

  • 1.4086
  • 1.6971
  • 2 3967 *
  • 1.7030
  • 1.4169
  • 1.6943
  • 1.4107
  • 1.5 11
  • 1.5797
  • 1.3730
  • 1.5829
  • 1.3902
  • 1.6086
  • 1.3816
  • 1.4448 *

.7979 *

.... 182

  • 1. 6350
  • 1. 4149
  • 1. 6169
  • 1.3858
  • 1.6116 '.1.5285..*.2. 7321..*
  • 1.4 12
  • 1.3527
  • 1.5951
  • 1.4266
  • 1.6054
  • 1.3966
  • 1.5476
  • 1.0978 *

................................................. 377

  • 2.0098 '.
  • 1.6568
  • 1.4092
  • 1.5709
  • 1.3801
  • 1.6005
  • 1.4............

13

  • 1.3955
  • 1.3987
  • 1.5797
  • 1.3805
  • 1.5476
  • 1.0924 *

.7936 *

............................... 128

  • 1. 4377................... 10..*
  • 1.5924
  • 1.5889
  • 1.4096
  • 1.6
  • 2.0209
  • 2.76 14
  • 1.1481
  • 1.4673
  • 1.2970
  • 1.4437
  • 1.0967 *

.7936 *

.......... 1. 5033

  • 1.6984
  • 1.5285
  • 2.0090
  • 2.7631.*
  • 1.9094
  • 15
  • 1.1192 *

.8622 *

.9061 *

.7968

  • 1.9301
  • 2.5120
  • 2.399 1..*. 2.7334
  • M-SUB-Q AT 100% power, 200 EFPD, THIS IS LEVEL 9 OF 18 (LEVEL 18 = TCP CF CCRE, LEVEL 1 = BOTTOM)

H G

F E

D B

A j

.................................................C.......................

8

  • 1.1781
  • 1.5637 ' 1.3130
  • 1.5647
  • 1.3377
  • 1.3773
  • 1.1320
  • 1.1010 *
  • 1.9027
  • 1.4414
  • 1.7094
  • 1.4386
  • 1.6754
  • 1.6232
  • 1.9659
  • 2.0

................................................................... 148

  • l

)

9 ' 1.5637

  • 1.3602
  • 1.5765
  • 1.3645
  • 1.5733
  • 1.3816
  • 1.4501 *.6504
  • j

........................ 1

  • 1.6464 '.1.4301
  • 1.6220
  • 1.5453
  • 2.6080 *
  • 1.4414
  • 1.6514
  • 1.430 i

10

  • 1.3130
  • 1.5722
  • 1.3163
  • 1.5713 ' 1.4148
  • 1.5658
  • 1.2809 *

.8921 *

  • 1.7094
  • 1.4339
  • 1.7054
  • 1.4320
  • 1.5902
  • 1.4405
  • 1.7
  • 2.4893 *

.......................................................... 477 1.3655

  • 1.4266 *

.7850

  • 11
  • 1.5647
  • 1.3591
  • 1.5679
  • 1.3762
  • 1.5947 1.4386
  • 1.6514
  • 1.4357
  • 1.6353
  • 1.4181
  • 1.6489
  • 1.5742
  • 2.8380
  • 12 ' 1.3377
  • 1.5690 ' 1.4105 ' 1.5915
  • 1.3805
  • 1.5305
  • 1.0828 *

,....................................... 329

  • 1.4735
  • 2.0760 *
  • 1.6754
  • 1.4339
  • 1.5937
  • 1.4200
  • 1.6 13 ' 1.3773
  • 1.3816
  • 1.5637 ' 1.3645
  • 1.5305
  • 1.0785 *

.7808 *

................................. 1

  • 1.4735
  • 2.0859 '.2.8715 *
  • 1.6232
  • 1.6220
  • 1.4424
  • 1.650 14
  • 1.1320
  • 1.4491 ' 1.2798
  • 1.4255
  • 1.0817 *

.7797

  • 1.9659
  • 1.5461
  • 1.7491
  • 1.5753
  • 2.0760
  • 2.8715
  • 15
  • 1.1010 *.8493 *.8921 *

.7850

  • 2.0148
  • 2.6111

...................'..................2.4921

  • 2.8380
  • M-SUB-Q e

w-%

APPENDIX Page 16 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 10 0% F0WER, 200 EFED, THIS IS LEVEL 8 OF 18 (LEVEL 18 = TOP OF CCRE, LEVEL 1 : BOTTOM)

H G

F E

D C

B A

8

  • 1.1963
  • 1.6065
  • 1.3355
  • 1.6076
  • 1.3612
  • 1.4052
  • 1.1492
  • 1.1256 *
  • 1.8143
  • 1.3565
  • 1.5948
  • 1.5420
  • 1.8766
  • 1.9008 *

................... 1.6268

  • 1.3557
  • 9*

1.6065

  • 1.3859
  • 1.6194
  • 1.3912
  • 1.6140
  • 1.4094
  • 1.4865 *

.8632 *

  • 1.3565
  • 1.5685
  • 1.3465
  • 1.5629
  • 1.3482
  • 1.5398
  • 1.4587
  • 2.4777
  • 10
  • 1.3355
  • 1.6140
  • 1.3398
  • 1.6140
  • 1.4437
  • 1.6065
  • 1.3077 *

.9082

  • 1.3507
  • 1.6220
  • 1.3498
  • 1.5069
  • 1.3548
  • 1.6564
  • 2.3628
  • 6268 1.6076
  • 1.3859
  • 1.6086
  • 1.4030
  • 1.6397
  • 1.3944
  • 1.4630 *

.7979

  • 11 1.3557
  • 1.5685
  • 1.3532
  • 1.5S07
  • 1.3318 1.5596
  • 1.4834
  • 2.7013
  • 12
  • 1.3612
  • 1.6108
  • 1.4394
  • 1.6365
  • 1.4105
  • 1.5712
  • 1.1042
  • 1.3523
  • 1.5111
  • 1.3342
  • 1.5442
  • 1.3866
  • 1.9659 *
  • 1.5948 1.4084
  • 1.6054
  • 1.3934
  • 1.5712
  • 1.0978 *

.7925

  • 1.4052 13 *
  • 1.5409
  • 1.3565
  • 1.5607
  • 1.3866
  • 1.9784
  • 2.7249
  • 1.5420 1.4855
  • 1.3066
  • 1.4630
  • 1.1031 *

.7925

  • 1.1492 14

.............................. 4845

  • 1.9659
  • 2.7283
  • 1.8766
  • 1.4597
  • 1.6576 1.

15

  • 1.1256 *

.8622 *

.9082 *

.7966

  • 2.3641
  • 2.7013
  • M-SUB-Q
  • 1.9008
  • AT 10 0 % POWER, 200 EFPD, THIS IS LEVEL 7 CF 18 (LEVEL 18 = TCP OF CCBE, LEVEL 1 = B71 TOM)

H G

F E

D C

B A

8

  • 1.1963
  • 1.6161 1.3398
  • 1.6172
  • 1.3645
  • 1.4094
  • 1.1503
  • 1.1278 *

.......... 1 3104

  • 1.7660
  • 1.57......** 17
  • 1.5334
  • 1.4768
  • 1.7904
  • 1.8101 *

........** 15

  • 1.30 1.6161
  • 1.3902
  • 1.6290
  • 1.3955
  • 1.6247 1.4126
  • 1.4940 *

.8632

  • 9 *
  • 1.3104
  • 1.5198
  • 1.2956
  • 1.5055
  • 1.2951
  • 1.4764
  • 1.3922
  • 2.3665
  • 10
  • 1.3388
  • 1.6236
  • 1.3430
  • 1.6247
  • 1.4491
  • 1.6172
  • 1.3120 *

.9093 *

  • 1.5715
  • 1.2994 1.4525
  • 1.3029
  • 1.5843
  • 2.2532 *

................... 1.5653

  • 1.2971
  • 11
  • 1.6172
  • 1.3912
  • 1.6194
  • 1.4004
  • 1.6515
  • 1.3998
  • 1.4716 *

.7979 *

  • 1.3017 1.5107
  • 1.3005
  • 1.4968
  • 1.2839
  • 1.5040
  • 1.4204
  • 2.5759
  • 12
  • 1.3645
  • 1.6215
  • 1.4437
  • 1.6483 1.4159
  • 1.5808
  • 1.1063 *
  • 1.5334
  • 1.2978
  • 1.4559
  • 1.2864
  • 1.4946
  • 1.3383
  • 1.8899
  • 13
  • 1,4094 1.4116 1.6161
  • 1.3967
  • 1.5819
  • 1.1010 *

.7925 *

................... 1.3041

  • 1.5056
  • 1.3383
  • 1.9123
  • 2.6210
  • 1.4768
  • 1.4789 *

....c.......................................

14

  • 1.1503
  • 1.4930
  • 1.3109
  • 1.4716
  • 1.1053
  • 7915 *
  • 1.7904
  • 1.3931 1.5855
  • 1.4204
  • 1.8906
  • 2.6227 15
  • 1.1278 *

.8611 *

.9082 *

.7968

  • 2.2555
  • 2.5759
  • M-SUB-Q
  • 1.8101
  • l APPENDIX i

Page 17 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 200 EFFD, THIS IS LEVEu 6 0F 18 fLEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

.........**....................E.......D........C H

G F

B A

8

  • 1.1824
  • 1.5979
  • 1.3248
  • 1.5990
  • 1.3505
  • 1.3934
  • 1.1374
  • 1.1128 *

..................'............... 0

  • 1 4821..*.1. 4282...*.1. 7340
  • 1. 7575 *
  • 1.7048
  • 1.2656 1.5177
  • 1.259 9
  • 1.5979
  • 1.3752
  • 1.6119
  • 1.3827
  • 1.6076
  • 1.3966
  • 1.4700 *

.8514 *

....................................... 510

  • 1.4292
  • 1.34641.4531
  • 1.2

.....................*.2.2968

  • 1.2656
  • 1.4654
  • 1.2522
  • 10
  • 1.3248
  • 1.6065
  • 1.3291
  • 1.6076
  • 1.4341
  • 1.6011
  • 1.2970 *

.8954 *

..................................... 1.4023

  • 1.2554
  • 1.5313
  • 1.5177
  • 1.2558
  • 1.5114
  • 1.2529 *
  • 2.1888
  • 11
  • 1.5990
  • 1.3773
  • 1.6022
  • 1.1944
  • 1.6354
  • 1.3859
  • 1.4555 *

.7872 *

  • 1.2590
  • 1.4504
  • 1.2565 *.1 4436
  • 1 2363 '.1.4498
  • 1.3710
  • 2.4964
  • 12
  • 1.3505
  • 1.6033
  • 1.4287
  • 1.6322
  • 1.4019
  • 1.5647
  • 1.0924 *
  • 1.4821 + 1.2546
  • 1.4064
  • 1.2384
  • 1.4408
  • 1 2880
  • 1.8248
  • 13
  • 1.3934
  • 1.3955
  • 1.6001
  • 1.3848
  • 1.5658
  • 1.0881 *

.780B *

...........................***.................. 8426

  • 2.5359 *
  • 1.4282
  • 1.4302
  • 1.2568
  • 1.4507
  • 1.2876
  • 1.

14

  • 1.1374
  • 1.4769
  • 1.2959
  • 1.4544
  • 1.0924 *

.7797 *

  • 1.7340
  • 1.3472
  • 1.5323
  • 1 3714..*. 1.8255
  • 2.5374
  • 15
  • 1.1128 *

.8504 *

.8954 *

.7861

  • 1.7575
  • 2.3005
  • 2.1888
  • 2 4964
  • M-SUB-Q AT 100% POWER, 200 EPPD, THIS IS LEVEL 5 OF 18 (LEVEL 18 : TOP OF CORE, LEVEL 1 HOTTOM)

H G

F E

D C

B A

8

  • 1.1942
  • 1.6301
  • 1.3420
  • 1.6322
  • 1.3607
  • 1.4180
  • 1.1524
  • 1.1342 *

.................*..,****.......... 1.3964

  • 1 3424
  • 1.6364
  • 1.6503 *

. 1.6089

  • 1.1840
  • 1.4311
  • 1.1783
  • 9
  • 1.6301
  • 1.3944
  • 1.6440
  • 1.4019
  • 1.6397
  • 1.4180
  • 1.5080 *

.8622 *

  • 1.1840
  • 1. 3796
  • 1.1714

................................. 1. 3457 1.2619

  • 2.1705
  • 1.3684
  • 1.1720
  • 10
  • 1.3420
  • 1.6386
  • 1.3473
  • 1.6397
  • 1.4555
  • 1.6343
  • 1.3184 *

.9093 *

  • .................................... 1. 3205
  • 1.1758
  • 1. 4413
  • 2.0642 *
  • 1.4311
  • 1.1751
  • 1.4245
  • 1.1739
  • 11
  • 1.6322
  • 1.3966
  • 1.6333
  • 1.4137
  • 1.6697
  • 1.4073
  • 1.4855 *

.7968 *

  • 1.1783
  • 1.3736
  • 1.1770
  • 1.3591
  • 1.1559
  • 1.3641
  • 1.2845
  • 2.3614
  • 12
  • 1.3687
  • 1.6365
  • 1.4491
  • 1.6665
  • 1.4234
  • 1.5969
  • 1.1085 *
  • 1.3964
  • 1.1745
  • 1.3237
  • 1.1583
  • 1.3532 '.1.2056
  • 1.7193 *

.....s........

13

  • 1.4180
  • 1.4169
  • 1.6322
  • 1.4062
  • 1.5979
  • 1.1021 *

.7893

  • 1.3424
  • 1.3465
  • 1.1770
  • 1.3650
  • 1.2049
  • 1.7385
  • 2.3904
  • 14
  • 1.1524
  • 1.5069
  • 1.3173 ' 1.4855
  • 1.1085 *

.7883 *

  • 1.6364
  • 1.2628
  • 1.4422
  • 1.2852
  • 1.7207
  • 2.4011
  • 15 ' 1.1342 *

.8611 *

.9002 *

.7958

  • 2.1748
  • 2.0642
  • 2.3614
  • M-SUB-Q

APPENDIX Page 18 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 200 EFPD, THIS IS LEVEL 4 0F 18 (LEVEL 18 = TOP OF CCRE, LEVEL 1 : BOTTCMI

..........................................................B.........A H

C F

E D

C 8

  • 1.1685
  • 1.5915
  • 1.3163
  • 1.5958
  • 1.3430
  • 1.3902
  • 1.1299
  • 1.1063 *

................... 1.3857

  • 1.1462
  • 1.3540
  • 1.3017
  • 1. 5902
  • 1.6148 *
  • 1.5596
  • 1.1504
  • 9
  • 1.5915
  • 1.3655
  • 1.6076
  • 1.3762
  • 1.6033
  • 1.3869
  • 1.4737

.8439 *

  • 1. 1504
  • 1.*.3366
  • 1. 1390
  • 1. 3253..*.1.1390
  • 1.3071
  • 1.2286
  • 2. 1182
  • 10
  • 1.3163
  • 1.6022
  • 1.3195
  • 1.6011
  • 1.4234
  • 1.5969
  • 1.2906 *

.8868 *

....................... 05

  • 1. 1402.*.1.2811...*.1.1420
  • 1 4008
  • 2.0185 *
  • 1.3857
  • 1.1426
  • 1.30 11
  • 1.5958
  • 1.3698
  • 1.5958
  • 1.3837
  • 1.6301
  • 1.3762
  • 1.4512 *

.7775 *

. 1 1462

  • 1.3301
  • 1. 1438
  • 1 3181.**1 1227.....1. 3229
  • 1.2496
  • 2.3057
  • 12
  • 1.3430
  • 1.5990
  • 1.4100
  • 1.6268
  • 1.3912
  • 1.5594
  • 1.0828 *

.......... 1. 1420

  • 1. 2848
  • 1.1244
  • 1.3110
  • 1.1695
  • 1.6728 *
  • 1.3540
  • 13
  • 1.3902
  • 1.3869
  • 1.5947
  • 1.3752
  • 1.5594
  • 1.0764 *

.7679

  • 1.6870
  • 2.3452 *
  • 1. 3017
  • 1.3079
  • 1.1432.*.1.3237
  • 1. 1688
  • 14
  • 1.1299
  • 1.4726
  • 1.2895
  • 1.4501
  • 1.0817 *

.7679

  • 4017.....1.2503
  • 1 6728
  • 2.3452 *
  • 1.5902
  • 1.2293
  • 1.

15

  • 1.1063 *

.8429 *

.8868 *

.7775

  • 1.6148
  • 2.1223
  • 2.0185
  • 2.3057
  • M-SUB-Q AT 100% POWER, 200 EFPD, THIS IS LEVEL 3 CF 18 (LEVEL 18 = TOP OF COBE, LEVEL 1 = BOTTCM)

H G

D C

B A

......................F.........E..........................................

8

  • 1.1513
  • 1.5690
  • 1.3002
  • 1.5765
  • 1.3280
  • 1.3752
  • 1.1149
  • 1.0871 *
  • 1.5206
  • 1 1198
  • 1.3465
  • 1. 1135
  • 1.3150
  • 1.26.48
  • 1.5507............ 1. 5833 *

+

9

  • 1.5690
  • 1.3473
  • 1.5862
  • 1.3623
  • 1.5808
  • 1.3666
  • 1.4491 *

.8311 *

... 1198.*.1.3009

  • 1 1068
  • 1. 2856
  • 1.1085
  • 1.2751.*.1 2009..*. 2.0701 *
  • 1.

10

  • 1.3002
  • 1.5819
  • 1.3045
  • 1.5787
  • 1.3998
  • 1.5679
  • 1.2702 *

.8707

  • 1.3416
  • 1.1107
  • 1.2496
  • 1.1152
  • 1.3676
  • 1.9802 *
  • 1.3465
  • 1 1107 11
  • 1.5765
  • 1.3570
  • 1.5733
  • 1.3634
  • 1.6001
  • 1.3505
  • 1.4234 *

.7604

  • 1..*.

2.2674

  • 1.2924
  • 1.223
  • 1.1135..*. 1. 2901
  • 1.1141
  • 1. 2833
  • 1.0957
  • 12
  • 1.3200
  • 1.5754
  • 1.3966
  • 1.5969
  • 1.3666
  • 1.5294
  • 1.0614 *
  • 1 3150
  • 1 1118.*. 1 2525
  • 1 0973
  • 1 2796
  • 1.1432
  • 1.6370
  • 13
  • 1.3752
  • 1.3655
  • 1.5658
  • 1.3495
  • 1.5294
  • 1.0539 *

.7486 *

... 2648

  • 1. 2758
  • 1.1164
  • 1.2932
  • 1.1426
  • 1.6526
  • 2. 3105.*.
  • 1.

14

  • 1.1149
  • 1.4480
  • 1.2691
  • 1.4223
  • 1.0603 *

.7486 *

  • 1.5507
  • 1.2016
  • 1.3693
  • 1.2238 *

..................................... 1. 6390

  • 2.3105
  • 15
  • 1.0871 *

.8300 *

.8697 *

.7604

  • 1.5833
  • 2.0740
  • 1.9802
  • 2.2698
  • M-SUB-Q

]

APPENDIX Page 19 of 140 4

McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations

\\

l AT 100% POWER, 200 EFFD.

THIS IS LEVEL 2 OF 18 (LEVEL 18 = TOP OF CCRE, LEVEL 1 = BOTTOM)

...............................E........D H

G F

C B

A 8

  • 1.0667 ' 1.4394
  • 1.2017
  • 1.4544
  • 1.2327
  • 1.2584
  • 1.0207

.9660 *

  • 1 5937
  • 1.1853
  • 1.4144 *

......+................. 1. 1714

  • 1.3770
  • 1.3424
  • 1. 6477
  • 1.7338
  • 9* 1.4394
  • 1.2391 ' 1.4598
  • 1.2681
  • 1.4512
  • 1.2456
  • 1.2970 *

.7604 *

  • 1. 1853 '.1 3736
  • 1. 1682
  • 1.3407 *............................. 1 '. 1. 3032
  • 2 2035
  • 1.1726
  • 1.359 1

10

  • 1.2017
  • 1.4544
  • 1.2092
  • 1.4351
  • 1.2852
  • 1.4159
  • 1.1492 *

.7818 *

'.1 4144

  • 1.1720
  • 1.4053
  • 1. 1853
  • 1.3213
  • 1.1983
  • 1. 4685
  • 2 1452
  • 11
  • 1.4544
  • 1.2627
  • 1.4309
  • 1.2563
  • 1.4576
  • 1.2263 1.2659 *

.6812 *

  • 1.1714
  • 1.3457
  • 1.

..................... 1885

  • 1.3523
  • 1.1670
  • 1.3822
  • 1.3350
  • 2 4613
  • 12
  • 1.2327
  • 1.4501
  • 1.2820
  • 1.4544
  • 1.2413
  • 1.3655 *

.9543 *

  • 1.3770
  • 1.1739
  • 1.3245
  • 1.1695
  • 1.3667................ 2425
  • 1. 7703 1.

13

  • 1.2584
  • 1.2445
  • 1.4148
  • 1.2252
  • 1.3655 *

.9532 *

.6704 *

  • 1.3424
  • 1.3591
  • 1.

..................... 1989

  • 1.3831
  • 1.2418
  • 1.7732
  • 2.5093
  • 14 ' 1.0207 ' 1.2959
  • 1.1481
  • 1.2649 *

.9532 *

.6694 *

. 1.6477

  • 1.3040
  • 1.4695
  • 1.3358
  • 1.7703
  • 2.5093
  • 15 *

.9660 *

.7593 *

.7818 *

.6812

  • 1.7338
  • 2.2057 *

................... 2. 1452

  • 2 4641..* M-SUB-Q AT 100% F0WER, 200 EFFD, THIS IS LEVEL 1 0F 18 (LEVEL 18 = TCP OF CORE, LEVEL 1 m BUTTCM)

H G

F E

D C

B A

8*

.7775

  • 1.0249 *

.8461

  • 1.0507 *

.8825 *

.8697 *

.7144 *

.6201 *

  • 2.1452.*.1 6280
  • 1.9695
  • 1. 5867
  • 1.8863
  • 1.9077 2.3154
  • 2.6522
  • 9
  • 1.0249 *

.8600

  • 1.0464 *

.9264

  • 1.0517 *

.8439 *

.8857

.5334 *

  • 1 6200
  • 1.9398
  • 1.5948
  • 1.7994
  • 1.5833
  • 1.9677
  • 1.0606 *

.....................**................................... 3.0862

  • 10 *

.8461

  • 1.0410 *

.8568

  • 1.0571 *

.8954

  • 1.0067
  • 7647

.5226 *

  • 1.9695
  • 1. 6010
  • 1.9450
  • 1

................. 5764

  • 1. 8575
  • 1.6489
  • 2.1621
  • 3.1483
  • 11
  • 1.0507 *.9232
  • 1.0528 *

.8782

  • 1.0367 *

.8375 *

.8386 *

.4616 *

  • 1.5867
  • 1.8053
  • 1.5833 1.8961 1.6053
  • 1.9820
  • 1.9748
  • 3.5695
  • 12 *

.8825

  • 1.0507

.8932

  • 1.0346 *.8525 *

.9189 *

.6447 *

  • 1.8863
  • 1.5856 '. 1.8622..*.1 6089
  • 1.9484
  • 1.8053
  • 2.5682
  • 13 *

.8697

.8429

  • 1.0067 *

.8375 *.9189 *

.6608 *

.4520 *

. 1. 9077

  • 1.9677
  • 1.6501
  • 1.9820
  • 1.0053
  • 2.5064
  • 3.6529
  • 14 *

.7144 *

.8846 *

.7647 *

.8375 *

.6437 *

.4520

  • 2.3154
  • 1.8686
  • 2.1643
  • 1.9748
  • 2.5682
  • 3.6529
  • i 15 *

.6201 *

.5323 *

.5226 '

.4616

  • 2.6522 3.0905 *

................... 3 1483

  • 3.5695
  • M-SJB-Q I

APPENDIX Page 20 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 405 EFPD, THIS IS LEVEL 18 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

A

..........................................................B...........*.**

8*

7915

  • 1.0399 *

.9275

  • 1.0785 *

.9725 *

.9532 *.e461

  • 7518 *

...... * *...................... * * *

  • 7 0 3 7 '.1 9 0 6 7
  • 2.1310 *

............ 5919

  • 1.7997
  • 1.5187
  • 1.6792
  • 1
  • 1.0449
  • 1 9
  • 1.0399 *

.9221

  • 1.0731 *

.9864

  • 1.0753 *

.9275 *

.9618 *.6651 '

................'.... 10

  • 1.6685
  • 1.5276 '. 1.7745
  • 1.6953 '.2.4189 *

'.1.5919

  • 1.7965 1.55 10 *

.9275

  • 1.0699 *

.9436

  • 1.0774 *.9505
  • 1.0389 *

.8557 *

.6522 *

. 1 7997 *................................... 7495

  • 1. 6102
  • 1.9362..*.2. 4925
  • 1.5544
  • 1.7690
  • 1.5510
  • 1 11 ' 1.0785 *

.9853

  • 1.0753 *

.9457

  • 1.0399 *

.8943 *.9039 *

.5794 *

......**......... 1. 5534

  • 1.7830
  • 1.5626
  • 1. 8357
  • 1.8498
  • 2.8797 *

. 1.5107

  • 1.6699
  • 12 *

.9725

  • 1.0753 *

.9575

  • 1.0389 *.8150 *.9104 *

.7272 *

............................ 1. 5638

  • 1.7126
  • 1.6519
  • 2.2259
  • 1.6792
  • 1.5276
  • 1.7508
  • 13 *

.9532 *

.9275

  • 1.0389 *

.8932 *.9104 *

.6994 *

.5644 *

  • 1.7037
  • 1.7745
  • 1.6113
  • 1.8357
  • 1.6512
  • 2.1136
  • 2.7958 *

.8461 *

.9607

.8547 *

.9039 *

.7272 *

.5644 '

14 *

..................................... 2.2259

  • 2.7958
  • 1.9067
  • 1.6967
  • 1.9377
  • 1.8496
  • 15 *

.7518 *

.6640 *

.6522 *

.5794

..................'......... 2.8797

  • M-SUB-Q
  • 2.1310
  • 2.4189 2.4925
  • AT 100% POWER, 405 EFFD, THIS IS LEVEL 17 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 BO'ITOM1 H

G F

E D

C B

A 8

  • 1.0432
  • 1.3034
  • 1.1674
  • 1.3302
  • 1.1995
  • 1.1984
  • 1.0549
  • 1.0014 *

........... 932

  • 1.5729
  • 1.6457 *

............................ 1.2718.*.1.4009

  • 1.5981
  • 1.3244
  • 1.4953
  • 1.3 9' 1.3034
  • 1.1760
  • 1.3291
  • 1.2038
  • 1.3270
  • 1.1963
  • 1.2252 *

.8279

  • 1.3244
  • 1.4608
  • 1.2949
  • 1.4115
  • 1.2804
  • 1.4163
  • 1.3733 1.9933
  • 10
  • 1.1674
  • 1.3270
  • 1.1813
  • 1.3120
  • 1.2167
  • 1.2938
  • 1.1181 *

.8482 *

  • 1.49

..... 53

  • 1.2974
  • 1.4559
  • 1.3128
  • 1.4204
  • 1.3308
  • 1.5265
  • 1.9733
  • 1.3302 1.2017
  • 1.3088
  • 1.2038
  • 1.3066
  • 1.1556
  • 1.1910 '

.7486

  • 11 *

..... 18 *............. 1. 3144

  • 1.4423
  • 1.3020
  • 1.4750
  • 1.4539
  • 2.3013
  • 1.27 1.4125
  • 12
  • 1.1995
  • 1.3259
  • 1.2156
  • 1.3055
  • 1.1353
  • 1.2274 *

.9510 *

.... 009

  • 1.2002
  • 1.4 1.4................. 214
  • 1. 3024
  • 4.4297
  • 1.3367
  • 1.7730
  • 13
  • 1.1984 1.1974
  • 1.2938
  • 1.1556
  • 1.2274 *

.9510 '

7465 *

.........'......... 1. 3308 '.1. 4755

  • 1.3367
  • 1.7114
  • 2.2172 *
  • 1.3932 1.4171
  • 14
  • 1.0549
  • 1.2242
  • 1.1181
  • 1.1910 *

.9510 *

.7454 *

  • 1.5729
  • 1.3741
  • 1.5267
  • 1.4539
  • 1.7730
  • 2.2172
  • 15
  • 1.0014 *

.8263 *

.8482 *

.7486

  • 1.

..................... 9749

  • 2.3013
  • M-SUB-Q

I APPENDIX Page 21 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin)- Normal Operations AT 100% POWER, 405 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

....H.........G F

E D

C B

A 8* 1.1428

  • 1.4309
  • 1.2477
  • 1.4469
  • 1.2734
  • 1.2841
  • 1.1138
  • 1.0881 *

...... 4.***1.2555

  • 1.541

............ 1. 2019

  • 1.3574
  • 1. 3368
  • 1.5288 *............. 1 5545
  • 1.4496
  • 9
  • 1.4309
  • 1.2713
  • 1.4491
  • 1.2841
  • 1.4469
  • 1.2873
  • 1.3355 *

.8771 *

  • 1. 2555
  • 1 4120
  • 1. 2237......1. 3647
  • 1 2087 *

..... 3559

  • 1.2938
  • 1.9330
  • 1 10
  • 1.2477
  • 1.4459
  • 1.2616
  • 1.4351
  • 1.3130
  • 1.4148
  • 1.2070 *

.9146 *

  • 1. 4496
  • 1.2258..*.1 4055
  • 1. 2393
  • 1 3580
  • 1.2545..*. 1.4553
  • 1 8820
  • 11
  • 1.4469
  • 1.2820
  • 1.4319
  • 1.2959
  • 1.4384
  • 1.2563
  • 1.3088 *

.8054 *

  • 1.2019
  • 1.3655
  • 1.2401 *
  • ..... * *.................... 1. 3 8 4 4. *. 1. 2 3 2 3
  • 1 4121
  • 1 3 6 5 8
  • 2. 2 0 2 6
  • 12
  • 1.2734
  • 1.4469
  • 1.3120
  • 1.4373
  • 1.2649
  • 1.3720
  • 1.0357 *
  • 1 3574
  • 1.2087
  • 1.3589 *

.......................... 1. 2330

  • 1.3812
  • 1.2711
  • 1.6944
  • 13
  • 1.2841
  • 1.2873
  • 1.4148
  • 1.2552
  • 1.3720
  • 1.0474 *

.8129 *

  • 1.3368 *

...........1.3559

  • 1. 2545
  • 1.4121
  • 1.2711
  • 1.6467..**...............................

1307 *

  • 2.

14

  • 1.1130
  • 1.3355
  • 1.2059
  • 1.3088
  • 1.0357 *

.8129 *

. 1. 5288

  • 1. 2939
  • 1 4561
  • 1. 3658
  • 1. 6951..*. 2. 1319
  • 15
  • 1.0881 *

.8761 *

.9146 *

.8054

  • 1.5545
  • 1.9366
  • 1.0823
  • 2.2029
  • M-SUB-Q AT 100 % POWER, 405 EFFD, THIS IS LEVEL 15 OF 18 (LEVEL 18 = TOP OF CORE. LEVEL 1 = BOTI'OM)

H O

F A

...............................E........D.........C.......B B

  • 1.1631
  • 1.4758
  • 1.2670
  • 1.4876
  • 1.2884
  • 1.3034
  • 1.1213
  • 1.1096 *
  • 1.5297

.......... 1. 2621

  • 1.4716
  • 1.

................. 2061

  • 1. 3830
  • 1.3584
  • 1 5662
  • 1. 5697 9
  • 1.4758
  • 1.2959
  • 1.4908
  • 1.3066
  • 1.4898
  • 1.3088
  • 1.3698 *.8846 *
  • 1.262 1.*. 1 4375
  • 1.2283
  • 1.3876 *................................................. 1.9787
  • 1.2123
  • 1.3761
  • 1.3004
  • 10
  • 1.2670
  • 1.4876
  • 1.2820
  • 1.4833
  • 1.3398
  • 1.4555
  • 3.2274 *

.9275 *

  • 1. 4716
  • 1.2304

......................... 1. 2404

  • 1.3745
  • 1.2620
  • 1. 475.9
  • 1 9123.*
  • 1.4283
  • 11
  • 1.4876
  • 1.3045
  • 1.4801
  • 1.3227
  • 1.4844
  • 1.2831
  • 1.3452 *

.8161 *

  • 1. 2061..*.1.3676
  • 1.2433
  • 1.4045
  • 1.2413
  • 1.4357
  • 1.3763
  • 2.2427
  • 12
  • 1.2394
  • 1.4898
  • 1.3388
  • 1.4833
  • 1.2948
  • 1.4148
  • 1.0592 *
  • 1.3830
  • 1.2129
  • 1.3756
  • 1.2420
  • 1 4085
  • 1. 2874
  • 1. 7268
  • 13
  • 1.3034
  • 1.3088
  • 1.4555
  • 1.2831
  • 1.4140
  • 1.0721 *

.8290 *

................... 1.2620

  • 1.4357
  • 1.2871
  • 1.6860
  • 2.1872.*
  • 1.3584
  • 1.3761
  • 14
  • 1.1213
  • 1.3698
  • 1.2263
  • 1.3452
  • 1.0592 *

.8290 *

  • 1.5662
  • 1.3012
  • 1.4759
  • 1.3763
  • 1.7268
  • 2. 1872
  • 15
  • 1,1096 *

.6836 *

.9275 *

.8161

  • 1.5697 *

.......... 1 9821

  • 1.9138
  • 2.2431
  • M-SUB-Q I

i

APPENDIX Page 22 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report 1hable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 405 EFPD, THIS IS LEVEL 14 CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8* 1.1385

  • 1.4501
  • 1.2402
  • 1.4598
  • 1.2595
  • 1.2723 + 1.0913
  • 1.0828 *
  • 1.6082..*.1.3204
  • 1.5378
  • 1.2736
  • 1. 4684
  • 1. 4431
  • 1.6684
  • 1.6671.*

9

  • 1.4501
  • 1.2702
  • 1.4641
  • 1.2798
  • 1.4619
  • 1.2788
  • 1.3409 *

.8600 *

. 1. 3204

  • 1.5071
  • 1.2949
  • 1.4685
  • 1.2791 + 1.4587
  • 1.3752
  • 2.1110
  • 10
  • 1.2402
  • 1.4600
  • 1.2552
  • 1.4587
  • 1.3130
  • 1.4276
  • 1.1995 *

.9039 *

  • 1.5378
  • 1.2975
  • 1

..................... 5109

  • 1.3018
  • 1 4449
  • 1.3261
  • 1.5629
  • 2 0346
  • 11
  • 1.4598
  • 1.2777 1.4544
  • 1.2970
  • 1.4576
  • 1.2574
  • 1.3184

.7958

  • 1.2736
  • 1.4695
  • 1.3054
  • 1.4713
  • 1.3043
  • 1.5123
  • 1.4415
  • 2.3695
  • 12
  • 1.2595
  • 1.4619
  • 1.3120
  • 1.4566
  • 1.2702
  • 1.3880
  • 1.0367 *

... 4684

  • 1.2797
  • 1. 4459
  • 1.3053..*.1.4905
  • 1.3622
  • 1.8289 *
  • 1.

13

  • 1.2723
  • 1.2788
  • 1.4276
  • 1.2574
  • 1.3891
  • 1.0496 *

.8097 *

  • 1.4431
  • 1.4587
  • 1.3261
  • 1.5123
  • 1.3620
  • 1.7964
  • 2.3334
  • 14
  • 1.0913
  • 1.3409
  • 1.1984
  • 1.3184
  • 1.0367 *

.8086

  • 1.6684
  • 1.3761
  • 1.5629
  • 1.4415
  • 1.8289
  • 2.3353
  • 15
  • 1.0828 *

.8589 *

.9039 *

.7958

  • 1.6671
  • 2.1148
  • 2.0346
  • 2.

.............................. 3695

  • M-SUB-Q AT 100% POWER, 405 EFPD, THIS IS LEVEL 13 CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 : BOTTOM)

H G

F E

D C

B A

8

  • 1.1438
  • 1.4716
  • 1.2488
  • 1.4823
  • 1.2659
  • 1.2820
  • 1.0946
  • 1.0956 *
  • 1.6146
  • 1.3304
  • 1 5663
  • 1.3045
  • 1.5197................................................ 10
  • 1.7320 *................ 171
  • 1.49 1.7 9
  • 1.4716 + 1.2809
  • 1.4855
  • 1.2895
  • 1.4844
  • 1.2873
  • 1.3591 *

.8643 *

  • 1.3304
  • 1.5313
  • 1.3139
  • 1.S090
  • 1.3071
  • 1.5031
  • 1.4090
  • 2.1867
  • 10
  • 1.2488
  • 1.4833
  • 1.2638
  • 1.4823
  • 1.3238
  • 1.4400 1.2092 *

.9093 *

  • 1.5663
  • 1.3165
  • 1.5450
  • 1.3167
  • 1.4750
  • 1.3436
  • 1.6015
  • 2.0996
  • 11
  • 1.4823
  • 1.2873
  • 1.4700
  • 1.3077
  • 1.4791
  • 1.2670
  • 1.3366 *

.0000 *

  • 1.3045
  • 1.5122
  • 1.3209
  • 1.4956
  • 1.3217
  • 1.5421
  • 1.4572
  • 2.4

................................................................... 240

  • 12
  • 1.2659
  • 1.4833
  • 1.3227
  • 1.4780
  • 1.2798
  • 1.4073
  • 1.0453 *
  • 1.5197
  • 1.3077
  • 1.4760
  • 1.3227
  • 1.5315
  • 1.3923
  • 1.8700
  • 13
  • 1.2820
  • 1.2873
  • 1.4400
  • 1.2670
  • 1.4073
  • 1.0501 *

.8129 *

  • 1.4910
  • 1.5031
  • 1.3442
  • 1.5424
  • 1.3923
  • 1.8532
  • 2.4058
  • 14
  • 1.0946
  • 1.3591
  • 1.2001
  • 1.3366
  • 1.0453 *

.8129 *

  • 1.7330 * *.4097
  • 1. 5023
  • 1.4569
  • 1.9704........................

2.4078 *

......c.............

15

  • 1.0956 *

.8632 *

.9093 *.8000

  • 2.1889
  • 2.0996
  • 2.4240
  • N-SUB-Q

l APPENDIX Page 23 of 140 McGuire 2 Cylce 10 Core Operating Limits Report liable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin)- Normal Operations AT 1001 PCWER, 405 EFPD, THIS IS LEVEL 12 OF 18 (LEVEL 18 = TOP CF CORE, LEVEL 1 = DOTTOM)

H O

F E

D C

B A

8

  • 1.1320
  • 1.4630
  • 1.2359 ' 1.4737
  • 1.2531
  • 1.2702
  • 1.0817
  • 1.0849 *
  • 1.6863
  • 1.3833
  • 1 6358
  • 1.3580
  • 1 5960..*. 1 5658
  • 1 8252
  • 1.8032
  • 9
  • 1.4630
  • 1.2691
  • 1.4769
  • 1.2788
  • 1.4748
  • 1.2745
  • 1.3495 *.8536
  • 1.5689
  • 1.4697
  • 2.30

..................................... 1 3577 *

........................... 12 *

  • 1.3833
  • 1.5977
  • 1.3628
  • 1.5711
  • 10
  • 1.2359
  • 1.4737 + 1.2520
  • 1.4737
  • 1.3109
  • 1.4384
  • 1.1974 *

.8986 *

................................... 2012..*

1.5372

  • 1.3941
  • 1.6674
  • 2.
  • 1.6358
  • 1.3654
  • 1.6085 *

............................ 1. 3677

  • 11
  • 1.4737
  • 1.2766
  • 1.4694
  • 1.2959
  • 1.4694
  • 1.2552
  • 1.3270
  • 7904
  • 1.3580
  • 1.5745
  • 1.3714 + 1.5592
  • 1.3711
  • 1.6052
  • 1.5151
  • 2.5248
  • 12
  • 1.2531 ' 1.4737
  • 1.3098
  • 1.4683 ' 1.2681
  • 1.3966
  • 1.0346 '
  • 1.5960
  • 1.3583
  • 1.5383
  • 1.3722
  • 1.59 1.4414
  • 1.9439 *

......................................... 03

  • 13
  • 1.2702
  • 1.2745
  • 1.4384
  • 1.2541
  • 1.3966
  • 1.0464 *

.8032 *

.......................**... 1 6052

  • 1. 4404......'.1.9225
  • 2.5017 1.5658
  • 1.5689
  • 1.3941
  • 14
  • 1.0817
  • 1.3495
  • 1.1974
  • 1.3270
  • 1.0335 *

.8022 *

................................. 1

  • 1.9439
  • 2.5017
  • 1.0252
  • 1.4697
  • 1.6674
  • 1.515 15
  • 1.0849 *

.8525 *

.8986 *

.7904

.'.............................. 248

  • M-SUB-Q 1.8032
  • 2.3037
  • 2.2012
  • 2.5....

AT 100 % POWER, 405 EFPD, THIS IS LEVEL 11 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTCM)

H G

F E

D C

B A

  • 1.2552
  • 1,0678
  • 1.0710
  • 1.2231
  • 1.4600
  • 1.2391 8* 1.1171
  • 1.4501
  • 1.7791.*.1.4429
  • 1. 7149
  • 1.4217...............1. 6785
  • 1.6489
  • 1.9229
  • 1.8973
  • 9
  • 1.4501
  • 1.2552
  • 1.4641 ' 1.2659
  • 1.4619 1.2595
  • 1.3366 *

.8418 *

.......................................... 5

  • 1.6469
  • 1.5307
  • 2.4227
  • 1.4429
  • 1.6738
  • 1.4232
  • 1.6465
  • 1.419 10
  • 1.2231
  • 1.4608
  • 1.2391
  • 1.4619
  • 1.2970
  • 1.4255
  • 1.1835 *

.8868 *

  • 1. 7149
  • 1.4260
  • 1 6884
  • 1.4250 '.1.6089 '.1 4531.*.1.7454..*.2.3102
  • 11 ' 1.4608
  • 1.2638
  • 1.4576
  • 1.2820
  • 1.4566
  • 1.2402
  • 1.3130 *

.7797 *

  • 1.4217
  • 1.6489
  • 1.4294 1.6321
  • 1.6840
  • 1.5794
  • 2.6381 *

...........................'......... 1.4338

  • 12
  • 1.2391
  • 1.4619
  • 1.2948
  • 1.4544
  • 1.2531
  • 1.3837
  • 1.0207
  • 1.6765
  • 1.4195
  • 1.6101
  • 1.4353
  • 1.6702 1.5085
  • 2.0412 *
  • 1.0314 *

.7904

  • 13
  • 1.2552
  • 1.2595
  • 1.4255
  • 1.2402
  • 1.3837
  • 1.6489
  • 1.6460
  • 1.4531
  • 1.6840
  • 1.5085
  • 2.0177 2.6282
  • 14
  • 1.0678
  • 1.3366 ' 1.1835
  • 1.3130
  • 1.0207
  • 7904 *
  • 1.9229
  • 1.5387
  • 1.7459
  • 1.5794
  • 2.0412
  • 2.6290
  • 15
  • 1.0710 *

.6407 *

.8868 *

.7797

  • 2.4254
  • 2.3102
  • 2.6381
  • .....................................' M-SUB-Q

APPENDLX Page 24 of 140 McGuire 2 Cylce 10 Core Operating Limits Report ifable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 405 EPPD, THIS IS LEVEL 10 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

....H G

F E

D C

B A

8

  • 1.1256
  • 1.4737
  • 1.2327
  • 1.4855
  • 1.2499
  • 1.2691
  • 1.0753
  • 1.0860 *

. 1 0249

  • 1.4882..*.1.7665.*.1.4692.*.1 7478..*.1.7126
  • 2.0001..*.1 9583
  • 9*

!.4737

  • 1.2670
  • 1.4807
  • 1.2798
  • 1.4865
  • 1.2702
  • 1.3580 *

.8493

  • 1.4882
  • 1.7368
  • 1.46

....................... 99

  • 1. 7100
  • 1 4650
  • 1. 7109
  • 1. 5865
  • 2 5103
  • 10
  • 1.2327
  • 1.4855
  • 1.2499
  • 1.4865
  • 1.3098
  • 1.4491
  • 1.1963 *

.8964 *

  • 1 7665
  • 1.4729
  • 1.8050
  • 2.3875 *

............... 1.7391

  • 1.4679
  • 1.6700
  • 1.4967
  • 11
  • 1.4855
  • 1.2777
  • 1.4823
  • 1.2948
  • 1.4801
  • 1.2520
  • 1.3323 *

.7861 *

... 4692

  • 1.7132
  • 1.4722.*.1.6920
  • 1.4725
  • 1.7390 *.......................... 1.6237
  • 2.7266
  • 1 12
  • 1.2499
  • 1.4855
  • 1.3088
  • 1.4791
  • 1.2659
  • 1.4041
  • 1.0314 *
  • 1.7478
  • 1.4653
  • 1.6713
  • 1.4745
  • 1

....................................... 7266

  • 1.5489
  • 2.0974
  • 13
  • 1.2691
  • 1.2713
  • 1.4491 1.2520
  • 1.4041
  • 1.0410
  • 7968 *
  • 1.7126
  • 1.7100
  • 1. 4967
  • 1 7390..*.1. 5489...*.2.0815
  • 2..;74
  • 1.0753
  • 1.3500
  • 1.1963
  • 1.3334
  • 1.0314 *

.7968

  • 14 *

. 2 0001 *

........................... 6233.*.2.0908

  • 2.7074
  • 1.5866
  • 1.0055
  • 1 15
  • 1.0860 *

.8493 *

.8964

.7861

  • 1.9583
  • 2.5132..*. 2.3875
  • 2.7266
  • M-SUB-0 AT 100% POWER, 405 EFPD, THIS IS LEVEL 9 OF 18 (LEVEL 18 : TCP OF CORE, LEVEL 1 s BOTTCM)

H C

F E

D C

B A

8

  • 1.1085
  • 1.4555
  • 1.2156
  • 1.4683
  • 1.23?/
  • 1.2509
  • 1.0603
  • 1.0699 *
  • 1. 9184 *....... 1.5585 *

................. 1 5453

  • 1 8?26
  • 1.0009
  • 2 1141
  • 2. 0700
  • 1.8572
  • 9
  • 1.4555
  • 1.2499
  • 1.4705
  • 1.2638
  • 1.4683
  • 1.2520
  • 1.3398 *

.8365 *

  • 1.5585
  • 1

............ 8098

  • 1. 5431..*. 1 7906
  • 1.0442
  • 1.8024
  • 1. 6780
  • 2 6619
  • 10
  • 1.2156
  • 1.4673
  • 1.2327
  • 1.4705
  • 1.2906
  • 1.4309
  • 1.1002 *

.8825 *

.......... 1. 5463.*. 1. 8342.*. 1 5453

  • 1.7533
  • 1.5833
  • 1. 9077
  • 2 5267 *
  • 1.0572
  • 11
  • 1.4603
  • 1.2606
  • 1.4662 + 1.2777
  • 1.4619
  • 1.2349
  • 1,3141 *

.7743 *

  • 1.5453
  • 1.7950
  • 1.5496
  • 1.7717
  • 1 5529
  • 1.8310
  • 1.7175
  • 2.8828
  • 12
  • 1.2327
  • 1.4683
  • 1.2895
  • 1.4606
  • 1.2477
  • 1.3848
  • 1.0164 *
  • 1.8326..*. 1.5453
  • 1.7547
  • 1.555...... 6143..+.1.6353
  • 2.2169 *
  • 1 13
  • 1.2509
  • 1.2520
  • 1.4319
  • 1.2349 + 1.3859
  • 1.0260
  • 7840 *

............... 2.8602 *

  • 1.8009
  • 1.8024
  • 1.

..................... 5833

  • 1 8326
  • 1. 6341 2.1969
  • 14
  • 1.0603
  • 1.3398
  • 1.1792
  • 1.3141
  • 1.0164 *

.7840 *

  • 2.1141
  • 1.6780
  • 1.9077
  • 1.7161
  • 2.2169
  • 2.8602 *

)

15

  • 1.0699 *

.8365 *

.8825 *

.7743

  • 2.0700
  • 2.6619
  • 2.5267
  • 2.8820
  • M-SUB-Q

i l

APPENDIX Page 25 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 405 EFFD, THIS IS LEVEL 8 0F 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 = BOTTOM)

..................... F.......E H

G D

C B

A

................................s...**....

8

  • 1.1245
  • 1.4898
  • 1.2349
  • 1.5037
  • 1.2520
  • 1.2745
  • 1.0764
  • 1.0946 *

...........**...... 1. 7400

  • 1.4548
  • 1.7364
  • 1.7011
  • 2.0004.*.1 9600 *
  • 1.7951
  • 1.4685
  • 9 ' 1.4898
  • 1.2702
  • 1.5058
  • 1.2852
  • 1.5037
  • 1.2734 ' 1.3720 *

.8514

  • 1.6968
  • 1.4539
  • 1.7045 1.5814
  • 2.

.............'.. 4

  • 1.4539 *

.......................................'........... 5185 *

  • 1.4685
  • 1.

15 10

  • 3.2349
  • 1.5015
  • 1.2541
  • 1.5069
  • 1.3141
  • 1.4662
  • 1.2027 *

.8996 *

  • 1.7400
  • 1.4568
  • 1.7161
  • 1.4539
  • 1.6594
  • 1.4895
  • 1.8005
  • 2

.................................................................. 3867

  • 11
  • 1.5037
  • 1.2831
  • 1.5026
  • 1.3002
  • 1.4973
  • 1.2574
  • 1.3452 *

.7872 *

............... 1..*.1.4577

  • 1. 6773 '.1.4626
  • 1.7315
  • 1.6128
  • 2.7271..*
  • 1.4548
  • 1.700 12
  • 1.2520
  • 1.5037
  • 1.3130 ' 1.4962
  • 1.2702
  • 1.4169
  • 1.0357

....................... 07

  • 1.4636
  • 1.7160
  • 1.5381.*. 2.0903
  • 1.7364
  • 1.4548
  • 1.66 13
  • 1.2745
  • 1.2745
  • 1.4662
  • 1.2574
  • 1.4100
  • 1.0442 *

.7968 *

................... 1. 4885

  • 1. 7323
  • 1.5375
  • 2.0744 ' 2.7020 '
  • 1.7011
  • 1.7045
  • 14
  • 1.0764
  • 1.3709
  • 1.2027
  • 1.3452
  • 1.0357 *.7968 *
  • 2.0004
  • 1.5814

................... 1.8005

  • 1.6122
  • 2.0914
  • 2.7020
  • 15
  • 1.0946 *

.8514 *

.8996 *

.7872

  • 1.9(00 2.5

.........'... 214 '.2.3867

  • 2.7256.*. M-SUB-Q AT 100% POWER, 405 EFPD, THIS IS LEVEL 7 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

......................F.........E.........D H

G C

B A

8

  • 1.1278
  • 1.5005
  • 1.2402
  • 1.5155
  • 1.2564
  • 1.2820
  • 1.0817
  • 1.1031 *
  • 1.7030 *

.......... 1 3871...*.1 6484

  • 1.3731..*.1 6461
  • 1. 6108
  • 1 0984..*.1 8548.*

9* 1.5005

  • 1.2756
  • 1.5176
  • 1.2927
  • 1.5165
  • 1.2798
  • 1.3827 *

.8557 *

. 1. 3871..*. 1. 6260

  • 1. 3723.*. 1 6062.*.1. 3714
  • 1. 6.150
  • 1 4931..*.2. 3882.*

10

  • 1.2402
  • 1.5144
  • 1.2606 ' 1.5208
  • 1.3205
  • 1.4780
  • 1.2102 *

.9039 *

.......... 1.3757

  • 1.6237
  • 1.3706
  • 1.6484 *........................ 1. 5705
  • 1.4040
  • 1. 7045
  • 2.2633
  • 11 ' 1.5155
  • 1.2895
  • 1.5155
  • 1.3077
  • 1.5101
  • 1.2649
  • 1.3570 *.7915 *
  • 1 3731.*.1 6092 '. 1. 3749
  • 1.5869
  • 1. 3778
  • 1. 6375
  • 1.5222.*.2 5861..*

12

  • 1.2584
  • 1.5165
  • 1.3195
  • 1.5000
  • 1.2777
  • 1.428'
  • 1.0421 *
  • 1. 6461.'.1.3723...*.1.5716
  • 1. 3792
  • 1.6217... 1. 4500
  • 1. 9776
  • 13
  • 1.2620
  • 1.2009
  • 1.4791
  • 1.2649
  • 1.4298
  • 1.0496 *

.8000 *

  • 1.6100
  • 1.6150 *

........ *........ 1.4040

  • 1.6375
  • 1. 4495
  • 1.9524
  • 2. 5589
  • 14
  • 1.0817
  • 1.3827
  • 1.2102
  • 1.3570
  • 1.0421 *

.0000 *

  • 1.8784
  • 1.4936
  • 1 7045
  • 1.5222
  • 1.9776
  • 2.5589
  • 15
  • 1.1031 *

.8557 *

.9039 *

.7915

  • 1.8548
  • 2.3908
  • 2.2633
  • 2.5861
  • M-sUB-Q

APPENDIX Page 26 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F suo-Q OP Margin) - Normal Operations AT 100% F0WER, 405 EFPD, THIS IS LEVEL 6 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

A

..........................................................B...............

8* 1.1213

  • 1.4951 ' 1.2359
  • 1.5123
  • 1.2541
  • 1.2777
  • 1.0785
  • 1.0999 '

...... 2

  • 1.3317 '.1.5951..*.1.3168
  • 1.5794
  • 1.653
  • 1.5463
  • 1.8220
  • 1.7826
  • 9
  • 1.4951
  • 1.2713
  • 1.5133
  • 1.2895
  • 1.5133
  • 1.2756
  • 1.3805 *

.8525 *

. 1.3317........1.5607........1. 3160

  • 1.5393
  • 1. 3144
  • 1 5491

.......... 17

  • 2. 2968
  • 1.43....

10

  • 1.2359
  • 1.5101
  • 1.2563
  • 1.5176
  • 1.3173
  • 1.4758
  • 1.2070 *

.9007 *

  • 1.5951 *

.......... 1. 3192

  • 1.5699
  • 1.3128
  • 1.5058
  • 1.3452..*.1 6343
  • 2.1765
  • 11
  • 1.5123
  • 1.2873 ' 1.5123
  • 1.3045
  • 1.5069
  • 1.2616 ' 1.3537 *

.7883 *

. 1.3168

  • 1.5420

.................'.1.

3172 '.1 5205

  • 1.3192
  • 1. 5686
  • 1.4594..*.2. 4853 12
  • 1.2541
  • 1.5133
  • 1.3163 ' 1.5058
  • 1.2745
  • 1.4266
  • 1.0389 *
  • 1.5734
  • 1. 3152
  • 1. 5069
  • 1.3204..........................

3884.........

966 *

  • 1.5541
  • 1 1.8 13
  • 1.2777
  • 1.2766
  • 1.4758
  • 1.2616
  • 1.4265 + 1.0464

.7968 *

  • 1.5463
  • 1.549

............... 1....... 48

  • 1. 5686
  • 1.3800
  • 1.8817
  • 2.4601 *
  • 1.34 14
  • 1.0785 ' 1.3794
  • 1.2070
  • 1.3537
  • 1.0309 *

.7968

  • 1.0220 1.432

.........'..... 1...*.1.6350

  • 1.4590
  • 1.8973 2.4601 15
  • 1.0999 *

.8514 *

.9007 *

.7893

. 1.7826

  • 2.2993
  • 2.1765 2.4837

.........................'.........' M-SUB-Q AT 100% POWER, 405 EFPD, THIS IS LEVEL 5 0F 18 (LEVEL 18 = TOP OF CCRE, LEVEL 1 s BOTTCM)

H G

F E

D C

B A

8

  • 1.1470
  • 1.5412
  • 1.2659
  • 1.5604
  • 1.2863
  • 1.3163
  • 1.1074
  • 1.1363 '

'. 1.5244

  • 1.2311
  • 1.4701
  • 1.2162
  • 1.....................................................

1.7000

  • 1.6579
  • 4689
  • 1.4345
  • 9
  • 1.5412
  • 1.3023
  • 1.5604 1.3238
  • 1.5626
  • 1.3109
  • 1.4266 *

.8771 *

. 1.2311...*.1.4523

  • 1.2162
  • 1.4297
  • 1.2143
  • 1.4411..*. 1.3269..*.2.1457
  • 10 1.2659
  • 1.5562
  • 1.2895
  • 1.5669
  • 1.3516
  • 1.5251
  • 1.2424 *

.9264 *

  • 1.4701
  • 1.2189
  • 1. 4447
  • 1.2116
  • 1. 3990
  • 1 2431.'.1.5205
  • 2.0314
  • 11
  • 1.5604
  • 1.3216
  • 1.5615
  • 1.3398
  • 1.5572
  • 1.2970
  • 1.3987

.8097

  • 1.2162
  • 1.43

.'............. 25.*.1.2156

  • 1.4124
  • 1. 2184
  • 1. 4583
  • 1. 3521
  • 2.3241
  • 12
  • 1.2863 ' 1.5626
  • 1.3505
  • 1.5551
  • 1.3098 ' 1.4737
  • 1.0609 '
  • 1

... 4689

  • 1.2149
  • 1 3999
  • 1. 2197......1.4430........1. 2851
  • 1.7663
  • 13
  • 1.3163
  • 1.3109
  • 1.5251
  • 1.2970
  • 1.4737
  • 1.0753 *.8192 *
  • 1.4345
  • 1.4411
  • 1.243

........................ 1.*.1.4583 '. 1.2845

  • 1.7551
  • 2. 3021..*

14

  • 1.1074
  • 1.4266 ' 1.2424
  • 1.3907
  • 1.0603 *

.8182 *

  • 1.7000
  • 1.3270 *

....................1.5207

  • 1.3513
  • i.7663
  • 2.3021 15 ' 1.1363 *

.6761 *

.9275 *

.0097

  • 1.6579
  • 2.

............ 1478

  • 2.0311
  • 2.3241
  • M-SUS-Q

APPENDIX Page 27 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 100% POWER, 405 EPPD, THIS IS LEVEL 4 OF 18 (LEVEL 18 = TCP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

B A

........................................D.........C........................

8* 1.1428

  • 1.5358
  • 1.2638
  • 1.5572
  • 1.2873
  • 1.3152
  • 1.1106
  • 1.1363 *

......'... 909

  • 1.3602
  • 1.6085
  • 1 5752 *

................... 1.4128 '.1. 1537 1.4711

  • 1.1695
  • 1.3 9
  • 1.5358
  • 1.3002
  • 1.5562
  • 1.3248
  • 1.5615
  • 1.3120
  • 1.4276 *

.8782 *

. 1. 1695

  • 1.3706 *............... 1. 1542
  • 1.3526
  • 1 1507......... 44
  • 1.2568.*.2.0358 *
  • 1.36 10
  • 1.2638
  • 1.5530
  • 1.2884
  • 1.5647
  • 1.3516
  • 1.5251
  • 1.2445 *

.9275 *

  • 1.4128
  • 1.1567
  • 1.3873
  • 1.1489
  • 1.3251
  • 1.1771 1.4390
  • 1.9292
  • 1.5594
  • 1.3398
  • 1.5562
  • 1.2981
  • 1.3999 *

.8097

  • 11
  • 1.5572
  • 1.3227

... 15371......'.1.3551 1.1525

  • 1.3378
  • 1.1538
  • 1.3796
  • 1.2815
  • 2.2004
  • 12
  • 1.2873
  • 1.5604
  • 1.3505
  • 1.5551
  • 1.3109
  • 1.4748
  • 1.0699 *
    • .......... 1513
  • 1.3259
  • 1. 1549
  • 1. 3660
  • 1.2172
  • 1.6751 *
  • 1.3909
  • 1................................................

13

  • 1.3152
  • 1.3120
  • 1.5251 ' 1.2981
  • 1.4748
  • 1.0764 *

.8172 *

  • 1. 3602
  • 1.3643
  • 1.1771.*. 1.3796
  • 1 2166
  • 1.6651
  • 2.1880
  • 14
  • 1.1106 ' 1.4276
  • 1.2445
  • 1.3998
  • 1.0699 *

.8172 *

  • 1.6085
  • 1.2568
  • 1.4390
  • 1. 2807 '.1.6753
  • 2.1888
  • 15
  • 1.1363 *

.8771 *

.9275 *

.8097

  • 2.2080
  • M-SUB-Q 1.5752
  • 2.0377
  • AT 100% POWER, 405 EFPD, THIS IS.EVEL 3 CF 18 (LEVEL 18. TOP OF CORE, LEVEL 1 = BOTTOH)

F E

D C

B A

....H........G

....................................s.......................

1.5500

  • 1.2777
  • 1.5765
  • 1.3045
  • 1.3366
  • 1.1299
  • 1.1535
  • 8* 1.1524

................................. 1.3163

  • 1. 2830
  • 1.5185
  • 1.4910
  • 1.1095
  • 1.3451
  • 1.0920 *

. 1. 4104 9

  • 1.5500
  • 1.3120
  • 1.5733
  • 1.3430
  • 1.5808
  • 1.3302
  • 1.4501 *

.8932 *

............. 094

  • 1.0936
  • 1. 2792
  • 1.08A9
  • 1.2912
  • 1.1874 '. 1.9243.*.
  • 1.1095
  • 1.3 10
  • 1.2777
  • 1.5701
  • 1.3023
  • 1.5829
  • 1.3666
  • 1.5465
  • 1.2649 *

.9414 *

.............................. 1.2567

  • 1.1129
  • 1.3593
  • 1. 8274
  • 1.0963
  • 1.3187
  • 1.0878 *
  • 1.345

...... 1

  • 11
  • 1.5765
  • 1.3409
  • 1.5776
  • 1.3537
  • 1.5765
  • 1.3152
  • 1.4201 *

.8193 *

....................... 15

  • 1.2689
  • 1.0916
  • 1.3063
  • 1.2121
  • 2.0990 *
  • 1.0920
  • 1.2821
  • 1.09.................................................

12

  • 1.3045
  • 1.5000
  • 1.3655
  • 1.5744
  • 1.3200
  • 1.4951
  • 1.0849 *
  • 1.2941 1.1511
  • 1.5879 *

............... 3.. '.1. 2 5 7 5.. *.1. 0 9 2 7.................'..................

  • 1.3163
  • 1.089 13
  • 1.3366
  • 1.3313 ' 1.5476
  • 1.3152
  • 1.4962
  • 1.0881 *

.8257 *

  • 1.2830
  • 1 2905
  • 1.1124.*.1.30b3
  • 1. 1510
  • 1.5821..*.2.0050
  • 14 + 1.1299
  • 1.4501
  • 1.2649
  • 1.4212
  • 1.0839 *

.8257 *

.... 185

  • 1 1875..*.1. 3593.*.1. 2115
  • 1.5879
  • 2.0050 *
  • 1.5 15
  • 1.1535 *

.9921 *

.9414 *

.8204

  • 1.4910
  • 1.9260
  • 1.8274
  • 2.0970
  • M-sUB-Q d

[

APPENDIX Page 28 of 140 McGuire 2 Cylce 10 Core Operating Limits Report ifable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations l

AT 100% POWER, 405 EFPD, THIS IS LEVEL 2 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

.............G........F........E.........D.........C.........B.........A H

B

  • 1. 0 9 4 6
  • 1. 4 5 87
  • 1. 212 4
  • 1. 4 87 6
  • 1. 2 4 6 6
  • 1. 2 7 4 5
  • 1. 0 828
  • 1. 07 96 *

............ 1470 '.1.3768

  • 1.*.1245..*.1 3395 + 1.3111..*. 1. 5435
  • 1. 5543 *
  • 1.5237 *1 9
  • 1.4587
  • 1.2424
  • 1.4823
  • 1.2831
  • 1.4930
  • 1.2616
  • 1.3666 *

.8525 *

.....**............. 1284

  • 1.3017
  • 1 1210
  • 1. 3244
  • 1.'.263
  • 1.9656 *
  • 1 1470
  • 1.3443
  • 1 4

10

  • 1.2124
  • 1.4780
  • 1.2359
  • 1.4940
  • 1.2948
  • 1.4598
  • 1.1995 *

.8868 *

..**.................. 1.3968

  • 1 8918 *
  • 1.1471 *
  • 1 3768
  • 1.1313
  • 1.3500
  • 1. 1204
  • 1.2890

..**e.....

11

  • 1.4876
  • 1.2809
  • 1.4887
  • 1.2820
  • 1.4865
  • 1.2445
  • 1.3280 *

.7733 041...*.1. 1239 '.1. 3025..'.1.1256

  • 1. 3428
  • 1.2625
  • 2.1732..*

... 1245

  • 1.3
  • 1.

1.2466

  • 1.4919
  • 1.2938
  • 1.4844
  • 1.2563
  • 1.4052
  • 1.0217
  • 12 *

.............. 10

  • 1.2905
  • 1.1273
  • 1 3307
  • 1. 1934
  • 1.6415 *
  • 1.3395
  • 1.12 13
  • 1.2745
  • 1.2616
  • 1.4598
  • 1.2445
  • 1.4062
  • 1.0249 '

.7754 *

  • 1.3111..*. 1. 3244.*. 1. 1466
  • 1.3428
  • 1. 1927 '. 1.6366
  • 2.1646
  • 14
  • 1.0028
  • 1.3666
  • 1.1995
  • 1.3280
  • 1.0217 *

.7754 *

  • 1.5435..*.1.2263..*..!.3968
  • 1.2619
  • 1 6426
  • 2.1646
  • 15 ' 1.0796 *

.8525 *

.8868

  • 7733

. 1 5543...... 9689

  • 1.8918
  • 2. 1710
  • M SUB-Q
  • 1 AT 100% POWER, 405 EFPD, THIS IS LEVEL 1 0F 18 (LEVEL 18 TOF CF CORE, LEVEL 1 BOTICM)

H G

F E

D C

B A

8*

.8429

  • 1.0849 *

.9104

  • 1.1138 *

.9521 *

.9532 *

.8204

.7561 *

................................. 6

  • 1.7282
  • 1.7282 '.2.0131 '. 2. 1919 *
  • 1.9528
  • 1.5180
  • 1.8084
  • 1.478 9* 1.0849 *

.9243

  • 1.1085 *.9950
  • 1.1203 *

.9264

  • 1.0014 *

.6469 *

.................. 1. 4 8 5 6 '.1.6 5 4 9

  • 1. 4 7 0 0 '. 1. 7 7 9 6
  • 1. 6 5 01. *. 2. 5 6 0 3 *
  • 1 5180
  • 1.7821
  • 10 *

.9104

  • 1.1042 *.9286
  • 1.1256 *

.9682

  • 1.0903 *

.8697

.6405 *

=

..................'.................................... 1.8996

  • 2.5871 *
  • 1.8084
  • 1.4916 1.7736
  • 1.4621
  • 1.7017
  • 1.5119
  • I 11
  • 1.1138 *

.9928

  • 1.1235 *

.9543

  • 1.1106 *.9253 *.9543 *

.5676 *

  • 1 4786
  • 1.6574

.......................'...........................**... 5.****2.9242 *

  • 1.4650 1.7255 + 1.4836
  • 1.7837
  • 1.733 12 *.9521
  • 1.1192 *.9671
  • 1.1085 *

.9361

  • 1.0271 *

.7486 *

.......... 1. 4700

  • 1 7031
  • 1 4856
  • 1.7624..*.1.6092
  • 2.2112 *-
  • 1.7202
  • 13 *

.9532 *

.9264

  • 1.0903 *

.9253

  • 1.0282 *

.7647 *

.5633 *

....................... 19

  • 1.7837
  • 1.6C82
  • 2.1641
  • 2.9473 *
  • 1.7282
  • 1.7794
  • 1.51 14 *

.8204

  • 1.0014 *

.0697 *.9553 *.7486 *.5633 *

  • 2.0131 1.6511 1.8996
  • 1.7323
  • 2.2112
  • 2.947

..........'.........'................................ 3 *

.6453 '

.6405 *. 5 67 6

15 *

.7561

  • 2.1919
  • 2.5633
  • 2.5871 2.9203

...........................'........' H-SUB-Q l

APPENDIX Page ?)of140 McGuire 2 Cylce 10 Core Operating Limits Report

'rable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 4 EFPD, THIS IS LEVEL 18 CF 18 (LEVEL 18 : TOP CF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.5751 *

.8107 *

.7486 *

.9264 *

.8225 *

.8215 *

.7144 *

.5805 *

  • 2.5192
  • 2.0430
  • 2.1976
  • 1 7735.*.1. 9945
  • 1.9930
  • 2.2875
  • 2. 7942
  • 9*

.8107 *

.7165 *.8868 *.8215 *

.9221 *

.7797 *

.0075 *

.5200 *

............................ 1 9990

  • 1.7801
  • 2 1002
  • 2.0223 *
  • 2.0430
  • 2.3013
  • 1.8565
  • 3.0688
  • 10 *

.7486 *

.8857 *

.7593 *

.8836 *

.7722 *

.8589 *

.7036 *

.4873 *

  • 2.1976
  • 1.8570
  • 2.1659
  • 1.8565
  • 2.1239
  • 1.9077
  • 2.3237 *................................................................ 3 3246
  • 11 *

.9264 *

.8204 *

.0004 *

.7251 *

.7808 *

.6662 *

.6726 *

.4102 *

  • 1 7735
  • 2.0011
  • 1.8625
  • 2. 2654
  • 2.0393
  • 2.4247
  • 2.4256
  • 3.9566
  • 12 *

.8225 *

.9232 *

.7711 *

.7786 *

.5484 *

.5869 *

.4991 *

  • 1.9945
  • 1.7794
  • 2.1272
  • 2.0440
  • 2.3777
  • 2.2528
  • 3.0502
  • 13 *

.8215

  • 7797 *

.8579 *

.6662 *

.5869 *.4123 *

.3213 *

............... 2

  • 1.9090
  • 2.4269.*.7.2528
  • 2.9667
  • 4.3499 *
  • 1.9930
  • 2.101.............................................

.7144 *

.8065 *

.7026 *

.6715 *

.4991 *

.3213

  • 14 *
  • 2.2875
  • 2.0254
  • 2.3270
  • 2.4278
  • 3.0505
  • 4.3499
  • 15 *

.5805 *

.5200 *

.4862 *. 4 0 91

  • 3.0744
  • 3.3312
  • 3.9625
  • M-SUB-Q AT 75% POWER, 4 EFPD, THIS IS LEVEL 17 0F 18 iLEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

1.2049

  • 1.0324 *

.9125

  • 8*

7540

  • 1.0796
  • 1.0153
  • 1.1845
  • 1.1278

............................... 1 5225

  • 1.4210
  • 1.6521
  • 1.0597
  • 1.6067 + 1.6975
  • 1.4528 *

..... 97 *

  • . 95 9* 1.0796
  • 1.0014
  • 1.1663
  • 1.0935
  • 1.2006
  • 1.1695
  • 1.1620 *

.7700 *

  • 1.6067
  • 1 7260
  • 1.4784
  • 1. 5714
  • 1. 4295..*. 1 4650
  • 1. 4725.*.2.2035.*

l j

10

  • 1.0153
  • 1.1620
  • 1.0239 + 1.1481
  • 1.0999
  • 1.1685
  • 1.0432 *

.7336 *

................*.................... 1.5607

................. 1. 6399

  • 2.3139 *
  • 1.4699
  • 1.6975
  • 1.4829
  • 1.6009
  • 1.4978
  • 1.1845
  • 1.0924
  • 1.1449 *

.9950

  • 1.0592 *

.9778

  • 1.0196 *

.6233

  • 11 *

..... 28

  • 1.5732
  • 1.5016
  • 1.7308
  • 1.6095
  • 1 7231..*.1.6777
  • 2.7226
  • 1.45 12 + 1.1278
  • 1.2017
  • 1.0988
  • 1.0571 *

.7540 *.8729 *.7615 *

  • 1 5225
  • 1 4276.*. 1. 5616
  • 1. 6114
  • 1. 7051..*.1.6204
  • 2.0999
  • 13
  • 1.2049
  • 1.1695
  • 1.1674 *

.9768 *

.8718 *

.6233 *

.4873 *

.........................**......... 194

  • 2.1051
  • 3.0231
  • 1.4650
  • 1.4710
  • 1.7252
  • 1.6
  • 1. 4210
  • 14
  • 1.0324
  • 1.1610
  • 1.0410
  • 1.0185 *

.7604 *

.4873 *

............*............... 1.6797

  • 2 1000
  • 3.0231
  • 1.6521
  • 1.4746
  • 1.6419
  • 15 *

.9125 *

.7679 *.7:26 *

.6223

  • 1.6597
  • 2.2099
  • 2.3171
  • 2.7261
  • M SUS-Q i

APPENDIX Page 30 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report l'able 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Nomial Operations AT 75% POWER, 4 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 : TOP OF CORE, LEVEL 1 e BOTTOM)

H C

F E

D C

B A

8*

.8354

  • 1.2263
  • 1.1181
  • 1.3409
  • 1.2509
  • 1.3902
  • 1.1877
  • 1.0924 *
  • 1.8854
  • 1.5060
  • 1.6431
  • 1.3540
  • 1.4432
  • 1.2965
  • 1.5147
  • 1.6390
  • 9
  • 1.2263
  • 1.1160
  • 1.3141
  • 1.2081
  • 1.3891
  • 1.3462
  • 1.3730 *

.8900 *

  • 1.5060
  • 1.6492
  • 1.3922 *

............................ 1. 5039

  • 1.3014
  • 1. 3401
  • 1.3136
  • 2.0137
  • 10
  • 1.1181
  • 1.3098
  • 1.1256
  • 1.3055
  • 1.2584
  • 1.3591
  • 1.2252 *

.8643 *

  • 1.6431
  • 1.3971
  • 1. 6249
  • 1. 3956
  • 1. 4427

............... 1. 4723

  • 2.0729 *
  • 1.3345
  • 11
  • 1.3409
  • 1.2070
  • 1.3023
  • 1.1117
  • 1.2477
  • 1.1449
  • 1.2370 *

.7411 *

  • 1.3548
  • 1.5056
  • 1.3996 *

........................**. 1. 6529..+. 1. 4506

  • 1.5659
  • 1.4644
  • 2.4245
  • 12
  • 1.2509
  • 1.3912
  • 1.2574
  • 1.2456 *

.8697

  • 1.0592 *

.9189 *

............................ 1.4522

  • 1.5532
  • 1.4397
  • 1.4432
  • 1.2996
  • 1.4439 *
  • 1.8619
  • 13
  • 1.3902
  • 1.3462
  • 1.3500
  • 1.1438
  • 1.0592 *

.7540 *

.5869 *

  • 1.2965
  • 1. 3403
  • 1.3357 1.5668
  • 1.4390
  • 1.9965
  • 2.7073
  • 14
  • 1.1877
  • 1.3709
  • 1.2242
  • 1.2359 *

.9189 *.5869 *

  • 1.5147
  • 1.3153
  • 1.4739
  • 1.46

................................ 58

  • 1.8632
  • 2.7098
  • 15
  • 1.0924 *

.9868 *

.8622 *

.7390

  • 1.6390
  • 2.0191
  • 2.0755
  • 2.4287
  • M-SUB-Q AT 75% POWER, 4 EFFD, THIS IS LEVEL 15 OF 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.9136

  • 1.3366
  • 1.1931 1.4448
  • 1.3323
  • 1.5005
  • 1.2766
  • 1.1952 *

......................................... 49

  • 1 2789
  • 1. 4995..*.1. 5907
  • 1.9237
  • 1.5063
  • 1.6732
  • 1.3444
  • 1.44 9 ' 1.3366
  • 1.1995
  • 1.4159
  • 1.2884
  • 1.5069
  • 1.4523
  • 1.5090 *

.9596

  • 1.5063
  • 1.6683
  • 1.3894
  • 1.5138
  • 1.2781
  • 1.3234
  • 1.2730
  • 1.9888
  • 10
  • 1.1931
  • 1.4105
  • 1.1952
  • 1.4201
  • 1.3720
  • 1.4930
  • 1.3462 *

.9436 *

  • 1.6732
  • 1.3945
  • 1.6517 *

]

............................ 1.3790.*.1.4211

  • 1 2998
  • 1.4295
  • 2 0219
  • 11
  • 1.4448
  • 1.2841
  • 1.4159
  • 1.2059
  • 1.3907
  • 1.2777
  • 1.3987 *

.3161 *

  • 1.3444
  • 1.5146
  • 1.3836
  • 1.6560
  • 1 4109
  • 1.5329
  • 1.4007
  • 2.3547
  • 12
  • 1.3323
  • 1.5090
  • 1.3709 1.3966 *

.9917

  • 1.2274
  • 1.0437
  • 5..*.1 4224.*.1.4130
  • 1 5226
  • 1.3932
  • 1.8106 *
  • 1.4449
  • 1.276 13
  • 1.5005
  • 1.4523
  • 1.4919
  • 1.2766
  • 1.2263 *

.8793 *

.6704 *

. 1.2789

  • 1.3234
  • 1.3009
  • 1 5346
  • 1. 3925
  • 1.0538
  • 2.6567 14
  • 1.2766
  • 1.5069
  • 1.3452
  • 1.397
  • 1.0421 *

.6704

  • i
  • 1.4995
  • 1.2747
  • 1.4317
  • 1.4021
  • 1.0110
  • 2.6569
  • 15
  • 1.1952 *

.9564 *

.9414 *

.8140

  • 1.5907
  • 1.9940
  • 2.0248
  • 2.~a585
  • M-SUB-Q

[

APPENDIX Page 31 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1Dable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations l

l AT 75% POWER, 4 EFFD.

THIS IS LEVEL 14 CF 18 (LEVEL 18 = TOP OF CCRE, LEVEL 1 = HOTTOM)

H C

F E

D C

B A

................................**e......................................

8

  • 1.0239
  • 1.3998
  • 1.2316 ' 1.4844
  • 1.3623
  • 1.5300
  • 1.3066
  • 1.2263 *

............................ 1 4168

  • 1 5270
  • 1.3435
  • 1,5717 2.0451
  • 1.5924
  • 1.7860 *
  • 1.6590 *

..............**.........a.......

9

  • 1.3998
  • 1.2531
  • 1.4566
  • 1.3200
  • 1.5562
  • 1.4908
  • 1.5594 *

.9800 *

.....'.................. 1 6022 *. 1.3408 *

............................ 0835

  • 1.3912
  • 1.3261
  • 2

....S924 1.7665

  • 1.4694 *
  • 1.

10

  • 1.2316
  • 1.4512
  • 1.2263 ' 1.4726
  • 1.4276
  • 1.5540
  • 1.3998 *

.9714 *

... 7860 '.1.4753.*. 1. 7557

  • 1 4510
  • 1. 4955
  • 1.3604
  • 1 4978
  • 2.1234..*
  • 1 1.4844 ' 1.3238
  • 1.4673
  • 1.2649
  • 1.4951
  • 1.3655
  • 1.4887 *

.8504

  • 11

................... 1. 4561

  • 1. 7315
  • 1.4600
  • 1 5920
  • 1.4631
  • 2.4764.*

1.4160

  • 1.6049 *

.**...**e.............

12

  • 1.3623
  • 1.5551
  • 1.4266
  • 1.4930
  • 1.1578
  • 1.3816
  • 1.1256 *
  • 1 5270
  • 1.3390 '.1 4971
  • 1.4623.*.1.5899 '.1.4463
  • 1.8842
  • 13
  • 1.5380
  • 1.4908
  • 1.5530
  • 1.3634
  • 1.3816
  • 1.0057 *

.7347 *

  • 1 3435
  • 1.3919
  • 1. 3617 *... 1. 5937. ***...... 1..*. 1.9303
  • 2.7829 *
  • 1.446 14
  • 1.3066
  • 1.5372
  • 1.3977
  • 1.4876
  • 1.1245 *

.7347

......**........... 1.4993

  • 1 4(46 '.1.

0857

  • 1.5717
  • 1.3279 *
  • 2.7856
  • 15
  • 1.2263 *

.9778 *

.9703 *

.8493

  • 1.6590
  • 2.0894
  • 2.1263
  • 2.4807
  • M-SUB-Q AT 75% POWER, 4 EFPD, THIS IS LEVEL 13 CF 18 (LEVEL 18 = TOP CF CORE, LEVEL 1 = BOTTOM)

H G

P E

D C

B A

8

  • 1.1353
  • 1.5026
  • 1.3013
  • 1.5e37 ' 1.4223
  • 1.6194
  • 1..

1.2906 *

  • 2.1381

......1.6354

........... 31

  • 1. 4856 *.................... 5 '.1. 6.

1.7241.*

  • 1.89 1.6133
  • 1.405 9
  • 1.502o
  • 1.3398
  • 1.5412
  • 1.4030
  • 1.6579 ' 1.5690
  • 1.6526
  • 1.0228 *
  • 1.6354
  • 1.8261 1.5410
  • 1.6913
  • 1.4019
  • 1.4607
  • 1.3789
  • 2.

...................'........................**..................... 1871

  • 10
  • 1.3013
  • 1.5347
  • 1.2884
  • 1.5637 ' 1.5197
  • 1.6568
  • 1.4865
  • 1.0228
  • 1.8931
  • 1.5475
  • 1.8572
  • 1.5195
  • 1.5702 *
  • .............................................. 1.4190
  • 1.5652
  • 2.2222
  • 11
  • 1.5637 ' 1.3987
  • 1.5583
  • 1.3634
  • 1.6301
  • 1.4833
  • 1.6194 *

.9029 *

  • 1.4856
  • 1.6922
  • 1.5250
  • 1.7813
  • 1.4836
  • 1. 6280
  • 1. 4820
  • 2 6007
  • 12 ' 1.4223
  • 1.6558
  • 1.5187
  • 1.6268
  • 1.4298
  • 1.5883
  • 1.2338
  • 1.6133
  • 1.4000
  • 1.5719
  • 1.4858
  • 1.6453 *
  • .............................................. 1.4830
  • 1 9295
  • 13
  • 1.6194 1.5679
  • 1.6547 ' 1.4812
  • 1.5883
  • 1.1599 *

.8129 *

  • 1.4055
  • 1.4614
  • 1.4203
  • 1.629*
  • 1.4828
  • 2.0110
  • 2.8803
  • 14
  • 1.3645
  • 1.6493
  • 1.4844
  • 1.6183
  • 1.2327 *

.8118

  • 1.6516
  • 1.3809
  • 1.5677
  • 1.48

...... +......... +............... 3 5

  • 1. 9 318
  • 2. 8 8 3 2
  • 15
  • 1.2906
  • 1.0201
  • 1.0217

.9007

  • 1.7241
  • 2.1920
  • 2.2254
  • 2.6075
  • M-SUB-Q

e APPENDIX Page 32 of 140 McGuire 2 Cylce 10 Core Operating Limits Report liable 1 (cont.)

F-sub-QfM-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 4 EFFD, THIS IS LEVEL 12 0F 18 (LEVEL 18 = TCP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B

..............................................................**..A......

8

  • 1.1717
  • 1.5412
  • 1.3270
  • 1.5926
  • 1.4437
  • 1.6483
  • 1.3827
  • 1.3088
  • 2.3010
  • 1.7509
  • 2.0325
  • 1.6197
  • 1.7

........................................ 645

  • 1.5333
  • 1.8034
  • 1. 8743
  • 9 ' 1.5412
  • 1.3773
  • 1.5733
  • 1.4319
  • 1.6997
  • 1.6001
  • 1.6858
  • 1.0346 *
  • 1.7509
  • 1.9597

..................'.1.6814

  • 1.8483
  • 1.5275
  • 1.5963 '.1.4990
  • 2 3877
  • 10
  • 1.3270
  • 1.5658
  • 1.3120
  • 1.6011
  • 1.5572
  • 1.6997
  • 1.5197
  • 1.0399 *
  • 2.0325
  • 1.6082
  • 2.0343
  • 1.6552 *

..................................... 1. 7152

  • 1.5437............... 1. 7054
  • 2.4249
  • 11
  • 1.5926
  • 1.4266
  • 1.5947
  • 1.4084
  • 1.6922
  • 1.5369
  • 1.6804 *

.9232 *

  • 1.6197..........1.8505 '.1.6617

.......'.. 8994 '. 1.5748

  • 1.7314 '.1.5716.*. 2.8412
  • 1 12 ' 1.4437
  • 1.6975
  • 1.5551
  • 1.6890
  • 1.5101
  • 1.6772
  • 1.2831 *
  • 1.7645
  • 1.5252
  • 1. 7171
  • 1.5773
  • 1.7453
  • 1.5688
  • 2.0513
  • 13
  • 1.6483
  • 1.5990
  • 1.6975
  • 1.5347 ' 1.6793
  • 1.2263 *

.8493 *

  • 1.5333
  • 1.5972
  • 1.5460
  • 1.7334
  • 1.5586
  • 2.1327
  • 3.0619
  • 14 ' 1.3827 '

1.6836

  • 1.5176
  • 1.6793
  • 1.2820 *

.8482 *

  • 1.8034
  • 1.5012 ' 1.7084 1.5724
  • 2.0529
  • 3.0619
  • 15
  • 1.3088
  • 1.0314
  • 1.0378 *

.9211

. 1 8743.*.2.3951

  • 2.4290
  • 2.8468
  • M-SUB-Q

....................e.....

AT 75% POWER, 4 EFPD, THIS IS LEVEL 11 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTitM)

H G

F E

D C

B A

8

  • 1.1760
  • 1.5497
  • 1.3302
  • 1.5979
  • 1.4459
  • 1.6526
  • 1.3827 ' 1.3077 *

................................ 10

  • 1 9584
  • 1.6993
  • 2,0000
  • 2.0736 *
  • 2.4944
  • 1.8846
  • 2.1965
  • 1.79 9* 1.5497
  • 1.3837
  • 1.5797
  • 1.4373
  • 1.7104
  • 1.6044
  • 1.6922
  • 1.0314 *
  • 1.8846
  • 2.1150
  • 1.8446
  • 2.0308
  • 1. 6902
  • 1. 7730
  • 1.6572.*.2.6499
  • 10
  • 1.3302 1.5722
  • 1.3163
  • 1.6129
  • 1.5658
  • 1.7157
  • 1.5262
  • 1.0389 *
  • 2.1965
  • 1.8528
  • 2. 2165
  • 1 8073
  • 1 8592
  • 1.6936
  • 1.8878
  • 2.6887
  • 11
  • 1.5979
  • 1.4319
  • 1.6044
  • 1.4234 1.7136
  • 1.5530
  • 1.7007

.9264 *

  • 1.7910
  • 2.0393
  • 1.8141..*.2.0510
  • 1.6956
  • 1.8709
  • 1.6920
  • 3.0839
  • 12 ' 1.4459
  • 1.7093
  • 1.5637 ' 1.7104
  • 1.5347
  • 1.7082
  • 1.2970 *
  • 1.9504
  • 1.6683 '.1.0604.*.1.6905
  • 1.8911..*.1. 6959 '.2.2259
  • 13
  • 1.6526
  • 1.6033
  • 1.7125
  • 1.5508
  • 1.7093
  • 1.2456 *

.6600 *

  • 1. 6993
  • 1.7730
  • 1.G966 '.1.8723 '.1.6949
  • 2.3132
  • 3.3223
  • 1 14
  • 1.3927
  • 1.6090
  • 1.5240
  • 1.6997
  • 1.2959 *

.8589 *

  • 1.0C00
  • 1.6600
  • 1.3902 '.1 6930
  • 2.2276 '.3.3260
  • l i

15

  • 1.3077 1.0282
  • 1.0378 *

.9243 F-SUB-Q

'.2.0736

  • 2.6569
  • 2.6934.*.3.0905
  • M-SUB-Q l

APPENDIX Page 33 of 140 McGuire 2 Cylce 10 Core Operating Limits Report a

Table 1 (cont.)

F sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Nomial Operations AT 75% POWER, 4 EFPD, THIS IS LEVEL 10 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

....H G

F E

D C

B A

8* 1.1877

  • 1.5787
  • 7.3484
  • 1.6279
  • 1.4651
  • 1.6815
  • 1.3998
  • 1.3302 *

................... 2 2990

  • 1.9019
  • 2.1126
  • 1.0395
  • 2.1992
  • 2.2609 *
  • 2.6095
  • 1.9646
  • 1.4030
  • 1.6108
  • 1.4619
  • 1.7468
  • 1.6301
  • 1.7265
  • 1.0432
  • 9* 1.5787
  • 1.9646
  • 2.2102
  • 1.9244
  • 2.1202
  • 1.7735
  • 1.8994
  • 1.7931
  • 2 9083
  • 10
  • 1.3484 1.6033
  • 1.3345
  • 1.6483
  • 1.5947
  • 1.7564
  • 1.5551
  • 1.0549 *
  • 2 2990
  • 1.9334
  • 2.32

................... 28

  • 1. 8822
  • 1.9450
  • 1.7660
  • 1 9928
  • 2. 9351
  • 11
  • 1.6279
  • 1.4S55
  • 1.6397
  • 1.4491
  • 1.7554
  • 1.5851
  • 1.7447 *

.9403 *

  • 1.9019
  • 2.1295
  • 1. 8920
  • 2.1420
  • 1.7681

....................... 1 7778

  • 3.3003 *
  • 1.9500
  • 12
  • 1.4651
  • 1.7447
  • 1.5915
  • 1.7522
  • 1.5701
  • 1.7543
  • 1.3259 *
  • 2 1126
  • 1.7757 *............... 1.9476
  • 1.7714

...................................... 452.*

  • 1.9793
  • 1.7714
  • 2.3 13
  • 1.6815
  • 1.6290
  • 1.7532
  • 1.5829
  • 1.7554
  • 1.2734 *

.8761 *

................... 1.7692

  • 1 9606
  • 1.7703
  • 2.4455
  • 3.5492 *
  • 1.8395
  • 1.9006
  • 14
  • 1.3998
  • 1.7232
  • 1.5519
  • 1.7436
  • 1.3238 *

.8750 *

  • 2.1992
  • 1.7953
  • 1.9955
  • 1.7800
  • 2.3471
  • 3.5535
  • 15
  • 1.3302
  • 1.0399
  • 1.0539 *

.9302

  • 2.2609
  • 2.9144
  • 2.9380
  • 3.3040
  • M-SUB-Q AT 75% PCWER, 4 EFPD, THIS IS LEVEL 9 CF 18 (LEVEL 18 = TOP OF CCRE, LEVEL 1 : BOTTOM)

H G

F E

D C

B A

8*

1.1610

  • 1.5455
  • 1.3195
  • 1.5958
  • 1.4351
  • 1.6461
  • 1.3698
  • 1.2991 *
  • 2.6283
  • 1.9766
  • 2.3136
  • 1.9118
  • 2.1233
  • 1.8477
  • 2.2068
  • 2.3136
  • 9
  • 1.5455
  • 1.3730
  • 1.5776
  • 1.4319
  • 1.7136
  • 1.5958
  • 1.6911
  • 1.0185 *

...............................**...................... 1 8042

  • 2.9559
  • 1.9766
  • 2.2237
  • 1.9359
  • 2.1342
  • 1.7833
  • 1.9131
  • 10
  • 1.3195
  • 1.5701
  • 1.3066
  • 1.6193
  • 1.5637
  • 1.7265
  • 1.5240
  • 1.0303 *
  • 2.3136
  • 1.9450
  • 2.3350
  • 1.8920
  • 1.9567
  • 1.7746
  • 2.0051
  • 2.9589
  • 11
  • 1.5958
  • 1.4255
  • 1.6097
  • 1.4234
  • 1.7254
  • 1.5562
  • 1.7136 *

.9200 *

....................... 19

  • 2.1515
  • 1.7757................................ 887
  • 1.9118
  • 2.1436
  • 1.90
  • 1.9699
  • 1.7 3.3228
  • 1.7115
  • 1.5604
  • 1.7222
  • 1.5422
  • 1.7265
  • 1.2991
  • 12
  • 1.4351
  • 2.1233
  • 1.7844
  • 1.9606
  • 1.7789
  • 1.9914
  • 1.7800
  • 2.3623
  • 1.5936
  • 1.7232
  • 1.5540
  • 1.7265
  • 1.2499 *

.8568

  • 13
  • 1.6461
  • 1.8477
  • 1.9143
  • 1.7778
  • 1.9712
  • 1.7800
  • 2.4620
  • 3.5085
  • 14
  • 1.3698
  • 1.6879
  • 1.5208
  • 1.7125
  • 1.2981 *

.8568 *

.........................<............. 3661 2.2068

  • 1.8065
  • 2.0079
  • 1.7909
  • 2.

3.5885

  • 15
  • 1.2991
  • 1.0153
  • 1.0282 *

.9178

  • 2.3136
  • 2.9649
  • 2.9649
  • 3.3304
  • M-SUB-Q

APPENDIX Page 34 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 4 EFPD, THIS IS LEVEL 8 0F 18 (LEVEL 18 = TOP OF CORE. LEVEL 1 BOTTOM)

H G

F E

D C

B A

8

  • 1.1610
  • 1.5626
  • 1.3248
  • 1.6129
  • 1.4405
  • 1.6622
  • 1.3741
  • 1.3120 *
  • 2.5637 *1

............ 8944

  • 2.2220
  • 1.8143
  • 2.0176
  • 1.7459
  • 2.0869
  • 2.1611
  • 9* 1.5626
  • 1.3005
  • 1.5947
  • 1.4416
  • 1.7339
  • 1.6076
  • 1.7125
  • 1.0207 *
  • 1.8944
  • 2.1452
  • 1.0488
  • 2. 0516
  • 1.7091
  • 1.8291
  • 1.7031
  • 2.7812
  • 10
  • 1.3248
  • 1.5872
  • 1.3130
  • 1.6376
  • 1.5765
  • 1.7500
  • 1.5300
  • 2.0367
  • 42..*.1 8166
  • 1.8908
  • 1. 7081
  • 1 9206
  • 2. 7865..*.
  • 2.2220
  • 1.8582
  • 2.24 1.6129
  • 1.4351
  • 1.6279
  • 1.4319
  • 1.7489
  • 1.5712
  • 1.7414 *

.9243

  • 11 *
  • 1.8143
  • 2.0603
  • 1.8245
  • 2.0899
  • 1.7131
  • 1.9001.*.1.7222
  • 3.1850
  • 12
  • 1.4405
  • 1.7318
  • 1.5733
  • 1.7457
  • 1.5583
  • 1.7511
  • 1.3120 *
  • 2.0176
  • 1.7111
  • 1.8920
  • 1.7161
  • 1.9346
  • 1.7222
  • 2.2936
  • 13
  • 1.6622
  • 1.6054
  • 1.7468
  • 1.5690
  • 1.7522
  • 1.2595 *

.8611

  • 1.9093
  • 1.7212
  • 2.3992
  • 3.5023 *
  • 1 7459
  • 1.8291
  • 1.7101 14
  • 1.3741
  • 1.7093
  • 1.5358
  • 1.7393
  • 1.3098 *

.8611 *

.................. 1.9244

  • 1 7243
  • 2.2954
  • 3.5065
  • 2.0869
  • 1.7051
  • 15 ' 1.3120
  • 1.0185
  • 1.0346 *

.9221

  • 2.1611
  • 2,7891
  • 2.7918
  • 3.1885
  • M-SUB-Q AT 7 5 % POWER, 4 EFPD, THIS IS LEVEL 7 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTCH)

H G

P E

D C

B A

8

  • 1.1395
  • 1.5422
  • 1.3045
  • 1.5915
  • 1.4160
  • 1.6376
  • 1.3505
  • 1.2916
  • 1.6633
  • 1.8594
  • 1.6065
  • 1.9295
  • 2.0010
  • 2.3913
  • 1.7533
  • 2.0516 9
  • 1.5422
  • 1.3602
  • 1.5744
  • 1.4201
  • 1.7125
  • 1.5819
  • 1.6890
  • 1.0014
  • 1.7533
  • 1.9914
  • 1.6942
  • 1.8847
  • 1.5660
  • 1.6835
  • 1.5643
  • 2.5818
  • 10
  • 1.3045
  • 1.5669
  • 1.2916
  • 1.6161
  • 1.5530
  • 1.7286
  • 1.5144
  • 1.0174 *

.................................**...**...... 1.56f0.*.1.7639

  • 2.5704
  • 2.0662
  • 1.6671
  • 1.7428 *
  • 2.0516
  • 1.7031 11
  • 1.5915
  • 1.4137
  • 1.6076
  • 1.4105
  • 1.7275
  • 1.5487
  • 1.7200 *

.9071 *

..................................... 1. 5986

  • 1.7844.*.1 6048
  • 2.9439
  • 1.6633
  • 1.8932
  • 1.6738
  • 1.9502
  • 12
  • 1.4180
  • 1.7104
  • 1,5497
  • 1.7243
  • 1.5358
  • 1.7307
  • 1.2906
  • 1.7438
  • 1.6021
  • 1.8430
  • 1.6262
  • 2.1483 *
  • 1.8594
  • 1.5677 1.7254
  • 1.5465
  • 1.7318
  • 1.2381 *

.8450

  • 13
  • 1.6376
  • 1.5797

........................................ 253

  • 2.2722
  • 3.2743
  • 1.7666
  • 1.L 1.6065
  • 1.6854
  • 1.5677 14
  • 1.3505
  • 1.6868
  • 1.5123
  • 1.7190
  • 1.2895 *

.8439 *

  • 1.9295
  • 1.5668
  • 1.7671
  • 1.6056
  • 2 1499
  • 3.2780
  • 15
  • 1.2916 *

.9982

  • 1.0164 *

.9050

  • 2.0010
  • 2.5887
  • 2.5750
  • 2.9469
  • M-SUB-Q

APPENDIX

. Page 35 of 140 McGuire 2 Cylce 10 Core Operating Limits Report lnable 1 (cont.)

. F-sub-Q/M-sub-Q Values (F-sub-Q OP. Margin) - Normal Operations AT 75% F0WER, 4 EFPD,: THIS IS LEVEL 6 0F 18

-(LEVEL 18 e TOP OF CORE, LEVEL 1 m BOTTOM)

....H.........G........F.........E.........D........C.........B........A.....

8

  • 1.1042
  • 1.4951
  • 1.2638
  • 1.5412
  • 1.3720
  • 1.5829
  • 1.3034
  • 1.2424 *

..***.18

  • 1. 6253
  • 1. 9093.*. 4 5660
  • 1.7522...*.1. 5179
  • 1 8291.*.1.9068.*.
  • 2.20 9
  • 1.4951
  • 1.3184
  • 1.5251
  • 1.3730
  • 1.6558
  • 1.5272
  • 1.6301 *.9628 *
  • 1 6253
  • 1.8407
  • 1 5873...*.1. 7681.*. 1. 4697
  • 1. 5856.*.1. 4787
  • 2. 4578.*.

10

  • 1.2638
  • 1.5176
  • 1.2509
  • 1.5637
  • 1.4994
  • 1.6718
  • 1.4608 *

.9778'*

. 1. 9093..*.1. 5960..*. 1 9334.*.1 5610

  • 1. 6308...*.1. 4690.*. 1. 6595
  • 2.4393..*

11

  • 1.5412
  • 1.3666
  • 1.5551
  • 1.3655
  • 1.6708
  • 1.4951
  • 1.6600 *.8738 *
  • 1.5660
  • 1. 7768.*.1. 5677
  • 1. 8065
  • 1.4817
  • 1 6558
  • 1.4908
  • 2. 7706..*

12

  • 1.3720
  • 1.6536
  • 1.4962
  • 1.6675
  • 1.4833
  • 1.6718
  • 1.2424 *
  • 1. 7522
  • 1. 4712
  • 1. 6326.*.1. 4847
  • 1. 7021.*.1. 5085
  • 2. 0024..*

13

  • 1.5829
  • 1.5251
  • 1.6686
  • 1.4930
  • 1.6729
  • 1.1931 *.9118 *

.'.1.5179

  • 1.5882..*.1. 4705.*.1.6576
  • 1. 5085
  • 2. 1202.*.3 0710
  • 14
  • 1.3034
  • 1.6279
  • 1.4587
  • 1.6579
  • 1.2402 *.6107 *

. 1. 8291.+.1. 4817

  • 1.6624
  • 1. 4923..*. 2 0051...*.3. 0742.*.

15

  • 1.2424 *

.9607 *

.9768 *

.8707

- 4

  • 1 9068.*. 2. 4661...*.2.4434.*.2. 7732..* M-SUB-Q l

AT 75% POWER, 4 EFPD, THIS is LEVEL' 5 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

B

......................F.........E.........D.........C..................A......

8

  • 1.0935
  • 1.4940
  • 1.2563
  • 1.5347
  • 1.3602
  • 1.5722
  • 1.2863
  • 1.2306 *
  • 2. 0246
  • 1. 4908
  • 1. 7639
  • 1.4493..*.1. 6308
  • 1.4108
  • 1 7141
  • 1. 7822.*.

9

  • 1.4940
  • 1.3120
  • l'5230
  • 1.3623
  • 1.6461
  • 1.5112
  • 1.6183 *.9478
  • 8...*.1. 6923
  • 1 4624
  • 1. 6381.*. 1. 3595
  • 1 4757..*. 1 3749
  • 2. 3118 *
  • 1.490 10
  • 1.2563
  • 1.5155
  • 1.2413
  • 1.5540
  • 1.4833
  • 1.6600
  • 1.4448 *.9650 *
  • 1. 7639
  • 1. 4705
  • 1. 7898.*.1. 4414
  • 1.5116
  • 1 3582
  • 1. 5436
  • 2. 2828..*

11

  • 1.5347
  • 1.3559
  • 1.5455
  • 1.3505
  • 1.6590
  • 1.4700
  • 1.6472 *.8568 *

... 4493

  • 1.6455
  • 1. 4479.*.1 6643...*.1 3614.*.1 5267
  • 1.*.3703..*.2. 5887 *
  • 1 12
  • 1.3602
  • 1.6440
  • 1.4801
  • 1.6558
  • 1.4662
  • 1.6590
  • 1.2252'*
  • 1 6 3 0 0...*.1. 3 614
  • 1. 5 L 3 2
  • 1. 3 6 3 9
  • 1. 5 4 94.. *.1 3 7 2 9
  • 1..,8 4 41
  • 13
  • 1.5722 e 1.5090
  • 1.6568
  • 1.4758
  • 1.6600
  • 1.1749 *.7968 *

.... 100

  • 1.4772
  • 1. 3601
  • 1.5283
  • 1. 3723
  • 1.9385.*. 2.8270...*
  • 1.4 14
  • 1.2863
  • 1.6161
  • 1.4426
  • 1.6451
  • 1.2242 *.7968 *
  • 1. 7141
  • 1. 3768
  • 1 5461..*.1.3723
  • 1.0453..*.2 8297
  • 15
  • 1.2306 *.9457 *.9628 *

.8557

  • 1.7822
  • 2.3191
  • 2 2864
  • 2.5910
  • M-SUB-Q n

-e

( i APPENDIX Page 36 of140 McGuire 2 Cylce 10 Core Operating Limits Report 1hable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin)- Normal Operations AT 75% POWER, 4 EFPD, THIS IS LEVEL 4 0F 18 (LEVEL 18 = TOP OF CORE. LEVEL 1 = BOTTOM)

H C

F E

D C

B A

8

  • 1.0528
  • 1.4341
  • 1.2092
  • 1.4694
  • 1.3034
  • 1.4983
  • 1.2209
  • 1.1588 *

. 1 5606

  • 1.4486 '. 1. 7111.*. 1.4169..*.1. 5925..*.1.3846
  • 1. 6913 '. 1. 7757
  • 9
  • 1.4341
  • 1.2627
  • 1.4619
  • 1.3034
  • 1.5647
  • 1.4351
  • 1.5315 *

.8954 *

  • 1.4486
  • 1.6399
  • 1 4245
  • 1.5995..*.1. 3350
  • 1. 4515
  • 1.3595
  • 2.2972..*.

10

  • 1.2092
  • 1.4533
  • 1.1931
  • 1.4823
  • 1.4094
  • 1.5744
  • 1.3666 *

.9093

  • 1.7111
  • 1.4322
  • 1.7306
  • 1.4087 *
  • ...................**................ 1.4824.*.1.3340
  • 1.5243
  • 2.2704 11
  • 1.4694
  • 1.2970
  • 1.4748 ' 1.2895
  • 1.5733
  • 1.4009
  • 1.5508 *

.8065 *

  • 1.4169 '.1 6065
  • 1. 4155
  • 1.6200
  • 1.3352
  • 1.4984.*.1. 3532..*. 2.5682..*

12

  • 1.3034
  • 1.5626
  • 1.4062
  • 1.5701
  • 1.3902
  • 1.5679
  • 1.1535 *

. 1.5925

  • 1.3371
  • 1 4839
  • 1. 3377
  • 1.5132
  • 1.3451
  • 1.8189
  • 13
  • 1.4983
  • 1.4330 1.5712
  • 1.3977
  • 1.5679
  • 1.1063

.7486 *

  • 1.3846 '.1.4529
  • 1.3364
  • 1.5000
  • 1.3451
  • 1.9019
  • 2.79

................................................ 18

  • 14
  • 1.2209
  • 1.5294
  • 1.3645
  • 1.5497
  • 1.1513 *

.7476 *

  • 1.6913
  • 1. 3614
  • 1.5267...............
1. 3544
  • 1 8211..*. 2.7918
  • 15
  • 1.1588 *

.8932 *

.9071 *

.8054

. 1. 7757

  • 2.3045
  • 2.2739 '.2 5727
  • M-SUB-Q AT 75% POWER, 4 EFFD, THIS IS LEVEL 3 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

.............................+...........................B.......A 8* 1.0282

  • 1.4009
  • 1.1845
  • 1.4309
  • 1.2691
  • 1.4437
  • 1.1642
  • 1.0924 *
  • 1.9068
  • 1.4000 * :.6586
  • 1.3820 '.1.5527
  • 1.3539
  • 1.6864
  • 1.7931 9
  • 1.4009
  • 1.2338
  • 1.4309
  • 1.2713
  • 1.5026
  • 1.3762
  • 1.4566 *

.8482 *

...... 0

  • 1. 5925
  • 1 3814
  • 1. 5551.*. 1.3189 + 1. 4357
  • 1.3570
  • 2.3099 *
  • 1.400 10
  • 1.1845
  • 1.4223
  • 1.1695
  • 1.4394
  • 1.3548
  • 1.5048
  • 1.3002 *

.8589

  • i
  • 1.6586 *

.......... 1. 3893

  • 1 6844
  • 1.3755
  • 1 4609
  • 1.3189
  • 1 5203
  • 2.2846
  • j 11
  • 1.4309
  • 1.2649
  • 1.4319
  • 1.2499
  • 1.5037
  • 1.3355
  • 1.4619 *

.7572 *

  • 1.3820 *

.......... 1. 5626

  • 1.382J
  • 1.5838 *

........................ 1. 3219

  • 1. 4862
  • 1. 3502...*.2.5979
  • 12
  • 1.2691 ' 1.5005 ' 1.3527
  • 1.5005
  • 1.3270
  • 1.4887
  • 1.0871 *
  • 1.5527
  • 1.3207
  • 1 4624
  • 1.3243
  • 1. 4969
  • 1 3389
  • 1. 8260
  • 12
  • 1.4437
  • 1.3741
  • 1.5015
  • 1.3334
  • 1.4887
  • 1.0453 *.7026 *

..... 39

  • 1.4372
  • 1.3207,.............,...... 1.4885
  • 1. 3383
  • 1. 9031.*. 2.8133 *
  • 1.36

...u.

14

  • 1.1642 ' 1.4541 1."981
  • 1.4608
  • 1.0849
  • 7026 *
  • 1.6864
  • 1.3595 1.5227
  • 1.3595
  • 1.8200
  • 2.8133
  • 15
  • 1.0924 *

.8461 *

.8579 *

.7561

  • 1.7931
  • 2.3154
  • 2.2882
  • 2.6025

.....................................' M-SUD-Q

APPENDIX Page 37 of l40 McGuire 2 Cylce 10 Core Operating Limits Report 1nable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 4 EFPD, THIS IC LEVEL 2 OF 18 (LEVEL 18 : TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.9521

  • 1.2788
  • 1.0935
  • 1.3098
  • 1.1695
  • 1.2777
  • 1.0217 *

.9221 *

............ 4870

  • 1.7335
  • 1.4558 '.1.6262
  • 1.4870
  • 1. 8559
  • 2.0531
  • 1.9887
  • 1

)

9

  • 1.2788
  • 1.1299
  • 1.3152
  • 1.1813 ' 1.3409
  • 1.2242
  • 1.2659 *

.7401 *

  • 1.4870
  • 1.6706
  • 1.,.4479
  • 1 6136
  • 1.4252.*.1 5551.*.1.5054
  • 2.5569
  • 10
  • 1.0935
  • 1.3088
  • 1.0881
  • 1.3086 ' 1.2177
  • 1.3334
  • 1.1342 *

.'379 *

  • 1.7335
  • 1.4558
  • 1.7459
  • 1.4580
  • 1.5652
  • 1.4329
  • 1.6796
  • 2.5659
  • i l

11 + 1.3098

  • 1.1760
  • 1.3023
  • 1.1449
  • 1.3366
  • 1.1835
  • 1.2391 *.
4
  • 1.4558
  • 1.6217
  • 1.4646
  • 1.6632
  • 1.4329
  • 1.6145
  • 1.5428
  • 2. _
  • 12
  • 1.1695
  • 1.3388
  • 1.2167
  • 1.3334
  • 1.1802
  • 1.2906 *

.9328

  • j
  • 1.6262
  • 1.4273
  • 1.5668
  • 1.4365
  • 1. 6199
  • 1.4847
  • 2.0473
  • i 13
  • 1.2777
  • 1.2231
  • 1.3313
  • 1.1813
  • 1.2916 *

.9104 *

.6040 *

)

  • 1.4870
  • 1.5576
  • 1.4343
  • 1.6 3.1540 *

............................... 172

  • 1.4839
  • 2.1019
  • 14
  • 1.0217
  • 1.2638
  • 1.1320
  • 1.2381 *

.9318 *

.6040

  • l
  • 1.0559
  • 1.5069
  • 1.6825
  • 1.5444
  • 2.0488
  • 3.1540
  • i 13 *

.9221 *

.7379 *

.7368 *

.6447

  • 2.0531
  • 2.5637
  • 2.5704
  • 2.9410
  • M-SUB-g j

AT 75% POWER, 4 EFFD.

THIS IS !EVEL 1 OF 18 i

(LEVEL 19 TOT CT PORE, LEVEL 1 = BOTTCM)

H d

F E

O C

B A

8*

.6887 *

.9071

  • 7443 *

.9564 *

.0086 *

.8225 *

.6738 *

.5505 *

  • 2.6914
  • 2.0445
  • 2 4893
  • 1.9437
  • 2.2972
  • 2.2546
  • 2.7445
  • 3.3611 *

.7540 *

.9339 *

.8375 *

.9650

  • 7861 *

.8247 *

.4841

  • 9*

.9071 *

  • 2.0445
  • 2 4558
  • 1.9901.*. 2.2169
  • 1.9295
  • 2.3642
  • 2.2529
  • 3.8236 *

.9307 *

.7604 *

.9521 *

.8150 *

.0350 *

.7154 *

.4648

  • 10 *

.7443 *

  • 2.4 893 + 1.9955
  • 2.44 34
  • 1. 9541
  • 2.2 810
  • 1. 9928
  • 2. 6002
  • 3. 9856
  • 11 *.9564 *.8343 *

.9468 *.7765 *

.9414 *

.7690 *

.7668 *

.4070 *

  • 1.9437
  • 2.2271
  • 1.9646
  • 2.3953
  • 1.9806
  • 2.4211
  • 2.4292
  • 4.5514
  • 12 *

.0096 *

.9618 *

.8118 *.9302 *

.7743 *.8365 *.5858 *

  • 2.2972
  • 1.s346
  • 2.2882
  • 1 9874
  • 2 4051
  • 2.2305
  • 3 1815
  • 13 *, 8 2 ". 5 *

.7850 *

.9328 *

.7679 *

.8365 -

.5944 *

.3856 *

  • 2.2546
  • 2.3661.*.1.9955
  • 2.4251..*. 2.2305
  • 3.1370
  • 4.8222
  • 14 *

.6758 *

.8236 *

.7144 *

.7658 *

.5848 *

.3856 *

  • 2.7445
  • 2.2563
  • 2.6025
  • 2.4332
  • 3.1850
  • 4.8222
  • 15 *

.5505 *

.4830 *

.4637 *. 4 070

  • 3.3611
  • 3.8287
  • 3.9910
  • 4.5514
  • M-SUB-Q

APPENDIX Page 38 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 200 EFFD, THIS IS LEVEL 18 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 BOTTOM)

H G

F E

D C

B A

L*

.6300 *

.9039 *.8311

  • 1.0078 *

.8975 *

.8771 *

.7593 *

.6469 *

  • 2.3493
  • 1.9173
  • 2.0764
  • 1. 7118
  • 1 9221
  • 1.9636
  • 2.2606
  • 2.6380
  • 9*

.9039 *

.8065 *

.9800 *

.9039 *

.9992 *

.8375 *

.8675 *

.5730 *

.............................. 9088

  • 1. 7258
  • 2 0527 1.9779
  • 2.9758 *
  • 1.9173
  • 2.1436
  • 1.7595
  • 1.......

10 *

.8311 *

.9800 *

.8407 *

.9757 *

.8514 *

.9296 *

.7497 *

.5409 *

  • 2.0764
  • 1.7619
  • 2.0500
  • 1.7642
  • 2.0195
  • 1.8481
  • 2.2877
  • 3.1447
  • 11
  • 1.0078 *

.9029 *

.9725 *

.0097 *

.8675 *

.7336 *

.7454 *

.4584 *

  • 1.7118
  • 1.9101
  • 1.7698
  • 2.1254 '.1 9473
  • 2.3214
  • 2.2621
  • 3.6954
  • 12 *

.8975'*

.9992 *.8504 *

.8664 *

.6003 *.6576 *.5505 *

  • 1.9221 '. 1.7258
  • 2.0225
  • 1.9496
  • 2.2125
  • 2.1196
  • 2.9258
  • 13 *

.8771 *

.8375 *

.9286 *

.7326 *

.6576 *

.4627 *

.3727 *

  • 1.9636
  • 2.052.9 '.1.8492
  • 2.3214
  • 2.1184
  • 2.7895
  • 3.9715
  • 14 *

.7593 *

.6664 *

.7497 *

.7443 *

.5505 *

.3727 *

  • 2.2606
  • 1.9808
  • 2.2896
  • 2.2841
  • 2.9258
  • 3.9715
  • 15 *

.6469 *

.5719 *

.5409 *

.4584

  • 2.6380
  • 2.9820
  • 3.1484
  • 3.6955
  • M-SUB-Q AT 75% POWER, 200 EFPD, THIS IS LEVEL 17 0F 18 (LEVEL 18 : TOP OF CORE, LEVEL 1 = BOTTOM)

H C

F E

D C

B A

8'

.0011

  • 1.1910
  • 1.1074
  • 1.2970
  • 1.1942
  • 1.2124 1.0410 *

.9500 *

  • 1.8715
  • 1 5147

......'.............. 9

  • 1. 5042
  • 1.4792 '.1.7153
  • 1.8604
  • 1.6239
  • 1.387 9
  • 1.1910
  • 1. 0913
  • 1. 2 8 31 + 1.1802
  • 1.2 8 6 3
  • 1.18 4 5
  • 1.197 4 *.7829 *
  • 1.5147
  • 1.6492
  • 1.4014 *

............................ 1. 5225

  • 1 3983
  • 1. 5133.*. 1. 4937
  • 2. 2710
  • 10
  • 1.1074
  • 1.2798
  • 1.1270
  • 1.2616
  • 1.1685
  • 1.2488
  • 1.0669 *

.7690 *

................... 1.5912 '.1.4217.................................. 1.6672

  • 2.3076
  • 1.6239
  • 1.4050 *
  • 1.5338
  • 1.4349
  • 11
  • 1.2970
  • 1.1792
  • 1.2595
  • 1.0999
  • 1.1642
  • 1.0271
  • 1.0796 *

.6490 *

  • 1 3879 + 1.5234

........................... 1.6290

  • 1.5291 '.1.7140
  • 1.6435
  • 2.7135 *
  • 1.4246
  • 1.1663
  • 1.1631 *

.0006 *

.9275 *.7818

  • 12
  • 1.1942
  • 1.287.1
  • 1 5042
  • 1.3977

...,**...........'............................... 16

  • 2.1347
  • 1.5356
  • 1.5308
  • 1.6701
  • 1.57 13
  • 1.2124
  • 1.1845
  • 1.2477
  • 1.0271 *.9275 *.6629 *.5291
  • 3.4792
  • 1.5133
  • 1.4357 *

............................ 1. 7151

  • 1.5710
  • 2.0940
  • 2.9035
  • 14 ' 1.0410
  • 1.1963
  • 1.0689
  • 1.0785 *.7B08 *

.5291 *

  • 1.7153
  • 1.4953
  • 1.6691..*.1. 6445
  • 2. 1358
  • 2.9035
  • 15 *

.9500 *

.7808 *

.7679 *. 64 80

  • 1.8694
  • 2.2748
  • 2.3093
  • 2.7162
  • M-SUB-Q

APPENDIX Page 39 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report 1hable 1 (cont.)

0-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 200 EFFD, THIS IS LEVEL 16 0F 18 (LEVEL 18 = TOP OF CCRE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.8729

  • 1.3366
  • 1.2049
  • 1.4512 + 1.3066
  • 1.3495
  • 1.1449
  • 1.0796 *
  • 1.7968
  • 1.4190
  • 1.5660
  • 1.2989
  • 1.4373
  • 1.3868
  • 1.6335
  • 1.72

.................................................................... 18

  • 9
  • 1.3366
  • 1.1974
  • 1.4373
  • 1.2927
  • 1.4459
  • 1.3216
  • 1.3602 *

.8611 *

...... 1. 2995

  • 1.4152
  • 1.3737 *........................ 2. 1627 *
  • 1.4190
  • 1.5796
  • 1. 3137
  • 1. 4547
  • 10
  • 1.2049
  • 1.4330
  • 1.2349
  • 1.4223
  • 1.3013
  • 1.4191
  • 1.2049 *

.8632 *

  • 1.5660
  • 1.3174
  • 1.5272
  • 1.3212
  • 1.4411
  • 1.3193
  • 1.5441
  • 2.1459
  • 11
  • 1.4512
  • 1.2916
  • 1.4201
  • 1.2156
  • 1.3195
  • 1.1578
  • 1.2424 *

.7315 *

..................................... 1. 4042

  • 1.5870
  • 1.4927
  • 2. 5176 *
  • 1.2989
  • 1.4563
  • 1.3244
  • 1.5485
  • 12
  • 1.3066 + 1.4459
  • 1.2991
  • 1.3173 *

.9029

  • 1.0667 *

.8868 *

........................... 560

  • 1.4349
  • 1.9709 *
  • 1.4056
  • 1.5
  • 1.4373
  • 1. 2995
  • 1.4433 13
  • 1.3495
  • 1.3216
  • 1.4100
  • 1.1578
  • 1.0667 *

.7529 *

.6008 *

  • 1.3864
  • 1.4153
  • 1.3200
  • 1.5879
  • 1.4346
  • 1.9532
  • 2.6928
  • 14
  • 1.1449
  • 1.3591
  • 1.2049
  • 1.2413 *

.8868 *

.6008 *

.......... 1.3744

  • 1.5450
  • 1. 4936
  • 1.9709
  • 2.6937 *
  • 1.6335
  • 15
  • 1.0796 *

.8589 *

.8632 *

.7304

.......... 2.1661.*.2.1476

  • 2.5100
  • M-SUB-Q
  • 1.7218
  • AT 75% PCWER, 200 EFPD, THIS IS LEVEL 15 0F 18 (LEVEL 18. TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.9146

  • 1.4201
  • 1.2584
  • 1.5412
  • 1.3623
  • 1.4105
  • 1.1845
  • 1.1342 *

..............**... 1.5986

  • 1.2936
  • 1.4549
  • 1.3971
  • 1.6626
  • 1.7271 *
  • 1.8347
  • 1.4232
  • 9
  • 1.4201
  • 1.2563
  • 1.5240
  • 1.3516
  • 1.5390
  • 1.3891
  • 1.4405 *

.8911 *

........................................ 2 2021.*.

1.2880

  • 1.4190
  • 1.3655 *
  • 1.4232
  • 1.6083
  • 1.3142
  • 1.4713
  • 10
  • 1.2584
  • 1.5197
  • 1.2916
  • 1.5144
  • 1.3741
  • 1.5112
  • 1.2713 *.9050 *

................... 1. 5523

  • 1. 3137
  • 1. 4434
  • 1 3068
  • 1.5423
  • 2.1543 *
  • 1.5986
  • 1.3187
  • 11
  • 1.5412
  • 1.3505
  • 1.5112
  • 1.2841
  • 1.4137
  • 1.2327
  • 1.3313 *

.7690 *

  • 1.2936
  • 1. 4729..*. 1.3169
  • 1.5592.*.1 3860
  • 1. 5861
  • 1.4761
  • 2.5278
  • 12
  • 1.3623
  • 1.5390
  • 1.3720
  • 1.4105 *

.9628

  • 1.1535 *

.9468 *

  • 1.4549
  • 1. 2881
  • 1.4442
  • 1.3881....................... 1 5581
  • 1.4239
  • 1 9774
  • 13
  • 1.4105
  • 1.3891
  • 1.5101
  • 1.2316
  • 1.1535 *

.8097 *

.6437 *

. 1. 3971.*. 1. 4197 1.3074

  • 1.5876
  • 1.4231
  • 1.9672
  • 2.7160
  • 14
  • 1.1845
  • 1.4394
  • 1.2702
  • 1.3302 *

.9457 *

.6426 *

  • 1.6626
  • 1.3669
  • 1.5440
  • 1.4769
  • 1.9784
  • 2.7169
  • 15
  • 1.1342 *

.8809 *

.9050 *

.7690

  • 1.7271
  • 2.2064
  • 2.1560
  • 2.5301
  • M-SUB-Q

APPENDIX Page 40 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 200 EPPD.

THIS IS LEVEL 14 OF 18 (LEVEL 18 = TOP CF CORE, LEVEL 1 = BOTTOM)

H C

F E

D C

B A

8*

.9489

  • 1.4512
  • 1.2745
  • 1.5551
  • 1.3645
  • 1.4094
  • 1.1760
  • 1.1267 *
  • 1.9441
  • 1.4973
  • 1.7112
  • 1.3737
  • 1.5574
  • 1.4942 1.7782
  • 1.8404
  • 9
  • 1.4512
  • 1.2788
  • 1.5412
  • 1.3591
  • 1.5540
  • 1.3966
  • 1.4437 *

.8836 *

  • 1.4973
  • 1.6999
  • 1.3958
  • 1.5705
  • 1.3680
  • 1.5177
  • 1.4533
  • 2.3540
  • 10
  • 1.2745
  • 1.5350
  • 1.3045
  • 1.5347
  • 1.3912
  • 1.5294
  • 1.2788 *

.9039 *

. 1 7112

  • 1.4002
  • 1.6555
  • 1.3960
  • 1.5412
  • 1.3917
  • 1.6516
  • 2.3103
  • 11
  • 1.5551
  • 1.3580
  • 1.5315
  • 1.3109
  • 1.4523
  • 1.2638
  • 1.3548 *

.7743 *

  • 1.3737
  • 1.5723
  • 1 3095
  • t.6619
  • 1.4563
  • 1.6736
  • 1.5819
  • 2.7224

...........................r................................

12

  • 1.3645
  • 1.5540
  • 1.3891
  • 1.4491
  • 1.0142
  • 1.2001 *

.9746

  • 1.5574
  • 1.3601
  • 1.5429
  • 1.4586
  • 1.6500
  • 1.5057 2.1005
  • 13
  • 1.4094
  • 1.3955
  • 1.5203
  • 1.2638
  • 1.2001 *

.8568 *

.6704 *

. 1. 4942

  • 1.5105
  • 1.3930
  • 1.6755
  • 1.5057
  • 2.0957
  • 2.9006
  • 14
  • 1.1760
  • 1.4426
  • 1.2777
  • 1.3537 *

.9746 *

.6694

  • 1.7782
  • 1.4548
  • 1.6536
  • 1.58
  • 2.1020
  • 2.90 27................ 35..*

15

  • 1.1267

.8814 *

.9029 *

.7733

..................... 3121

  • 2.7250
  • M-SUB-Q
  • 1.8404
  • 2.3582
  • 2 AT 75% POWER, 200 EFPD, THIS IS LEVEL 13 OF 18 (LEVEL 10 TOP OF CORE, LEVEL 1 = BOTTOM)

H C

F E

D B

A

.................................................C...................**..

8

  • 1.0785
  • 1.5476
  • 1.3334
  • 1.6204
  • 1.4041
  • 1.4501
  • 1.1995
  • 1.1567 *
  • 2.0229
  • 1.5318
  • 1.8147
  • 1.4472
  • 1.6600
  • 1.5888
  • 1.8990
  • 1.9438
  • 9
  • 1.5476
  • 1.3516
  • 1.6119
  • 1.4084
  • 1.6215
  • 1.4426
  • 1.4994 *

.8996 *

  • 1.5318 *

.......... 1. 7 5 6 0

  • 1. 4 7 2 2. +.1. 6717
  • 1. 4 410
  • 1. 615 0
  • 1. 5 3 6 5
  • 2. 5107. *.

10

  • 1.3334
  • 1.6065
  • 1.3537
  • 1.6076
  • 1.4512
  • 1.5979
  • 1.3248 *.9296 *
  • 1.0147
  • 1.4776
  • 1.7640
  • 1. 4743
  • 1.6391
  • 1.4719
  • 1.7569
  • 2.4575..*

11

  • 1.6204
  • 1.4030
  • 1.6033
  • 1.3805
  • 1.5519
  • 1.3441
  • 1.4287 *

.0011 *

  • 1.4472
  • 1.6738
  • 1.4703
  • 1.7310
  • 1.4955
  • 1.7310
  • 1.6623
  • 2. 9148
  • 12
  • 1.4041
  • 1.6204
  • 1.4491
  • 1.5487
  • 1.1749
  • 1.3816
  • 1.0464 *
  • 1.6600
  • 1.4419
  • 1.6419
  • 1.4979 *

..................................... 1. 7193

  • 1.5600
  • 2.1825
  • 13
  • 1.4501
  • 1.4416
  • 1.5969
  • 1.3441
  • 1.3816 *

.9714 *

.7304 *

  • 1.5888
  • 1.6167
  • 1.4726
  • 1.7327
  • 1.5598
  • 2.1996
  • 3.0365
  • 14
  • 1.1995
  • 1.4983
  • 1.3238
  • 1.4287
  • 1.0453 *

.7294 *

  • 1.0990
  • 1.5382
  • 1.7591
  • 1.6633
  • 2.1841
  • 3.0386
  • 15
  • 1.1567 *

.8975 *

.9286 *

.0011

  • 1.9438
  • 2.51F0
  • 2.4599
  • 2.9177
  • M-SUB-Q

APPENDIX Page 41 of 140 McGuire 2 Cylce 10 Core Operating Limits Report liable 1 (cont)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 200 EFPD.

THIS IS LEVEL 12 0F 10 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8

  • 1.1974
  • 1.6044
  • 1.3623
  • 1.6400
  • 1.4105
  • 1.4523
  • 1.1963
  • 1.1556 *
  • 2.1705
  • 1.6359
  • 1.9481.*.1. 5850
  • 1.8276
  • 1.7401
  • 2.0911..*. 2.1328
  • 9
  • 1.6044
  • 1.3944
  • 1.6400
  • 1.4244
  • 1.6418
  • 1.4533
  • 1.5123 *

.8964 *

  • 1 6359
  • 1.8815
  • 1.6138
  • 1. 8381
  • 1.5785
  • 1. 7794
  • 1.6855
  • 2.7616
  • 10
  • 1.3623
  • 1.6365
  • 1.3709
  • 1.6333
  • 1.4737
  • 1.6204
  • 1.3366 *

.9318 *

............ 6201...*.1 9352

  • 1. 6163
  • 1.7915
  • 1.6150
  • 1. 9330
  • 2.7041.*.
  • 1.9401
  • 1.

11

  • 1.6408
  • 1.4201
  • 1.6290
  • 1.4159
  • 1.6129
  • 1.3912
  • 1.4619 *

.8097 *

  • 1.5850
  • 1.0394
  • 1.6210
  • 1.8515
  • 1. 5905
  • 1. 8499
  • 1. 7766
  • 3.2032
  • 12
  • 1.4105
  • 1.6408
  • 1.4705
  • 1.6097
  • 1.3709
  • 1.5133
  • 1.0903 *
  • 1.8276
  • 1.5795
  • 1.7951
  • 1.5937

..................................... 1.0321

  • 1.6587
  • 2.3310
  • 13
  • 1.4523
  • 1.4523
  • 1.6194 1.3902
  • 1.5133
  • 1.0571 *

.7711 *

  • 1 7481..*.1.7803
  • 1.6159
  • 1. 8511
  • 1.6584
  • 2.3423
  • 3.2392
  • 14
  • 1.1963
  • 1.5112
  • 1.3355
  • 1.4608
  • 1.0892 *

.7700 *

  • 2.0911
  • 1.6874
  • 1.9354
  • 1.7777
  • 2.3323
  • 3.2392
  • 15
  • 1.1556 *

.8943

.9307 *

.8097

  • 2.1328
  • 2.7673
  • 2.7066
  • 3.2067
  • M-SUB-Q AT 75% POWER, 200 EFFD, THIS IS LEVEL 11 CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8

  • 1.2231
  • 1.6268
  • 1.3698
  • 1.6397
  • 1.4041
  • 1.4426
  • 1.1845
  • 1.1438 *

...... 1.*.1.7685

  • 2.1045
  • 1.7499
  • 2.0320
  • 1.9439
  • 2.3243
  • 2.3649 *
  • 2.358 9
  • 1.6260
  • 1.4137
  • 1.6461
  • 1.4255
  • 1.6429
  • 1.4400
  • 1.5090 *

.8868

  • 1.7685
  • 2.0379
  • 1.7457
  • 2.0119
  • 1.7396
  • 1.9670
  • 1.6700
  • 3.0675
  • 10
  • 1.3690
  • 1.6418
  • 1.3741
  • 1.6386
  • 1.4758
  • 1.6226
  • 1.3334

.9253 *

  • 2.1045
  • 1.7502
  • 2.0935
  • 1.7475 *
  • .................................... 1.9376
  • 1.7545
  • 2.1195
  • 3.0033
  • 11
  • 1.6397
  • 1.4212
  • 1.6343
  • 1.4287
  • 1.6451
  • 1.4116
  • 1.4716 *

.0097 *

  • 1.7499 *.2.0188
  • 1.7525
  • 2.0032
  • 1.7220
  • 2.0072
  • 1.9174
  • 3.4659
  • 12
  • 1.4041
  • 1.6400
  • 1.4726
  • 1.6410
  • 1.4159
  • 1.5626
  • 1.1074 *
  • 2.0320
  • 1.7417
  • 1.9424
  • 1.7250 *

..................................... 1 9881

  • 1.7954
  • 2.5308
  • 13
  • 1.4426
  • 1.4469
  • 1.6215
  • 1.4094
  • 1.5626
  • 1.0956 *.7893 *
  • 1.9439
  • 1.9679
  • 1.7558
  • 2.0100
  • 1.7951
  • 2.5411
  • 3.5178
  • 14
  • 1.1945
  • 1.5000
  • 1.3323
  • 1.4705
  • 1.1074 *

.7893 *

  • 2.3243
  • 1.8721
  • 2.1210
  • 1.9106
  • 2.5

........................................ 330

  • 3.5176
  • 15
  • 1.1438 *

.8857 *

.9243 *

.8086

  • 2,3649
  • 3.0739
  • 3.0064
  • 3.4670
  • M-SUB-Q

APPENDIX Page 42 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 7 5 % POWER, 200 EFFD, THIS IS LEVEL 10 CF 18 (LEVEL 18 TCP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8

  • 1.2445
  • 1.6665
  • 1.3902
  • 1.6718
  • 1.4191
  • 1.4598
  • 1.1931
  • 1.1588 *
  • 2.4829
  • 1 8559
  • 2.2254
  • 1.0523
  • 2.*.1805
  • 2.1156
  • 2. 5507
  • 2. 5734
  • 9
  • 1.6665
  • 1.4405
  • 1.6815
  • 1.4469
  • 1.6750
  • 1.4662
  • 1.5358 *

.8932 *

  • 1 8559
  • 2.1468
  • 1.8407
  • 2.1389
  • 1.8465
  • 2.1065
  • 2. 0024
  • 3.3569
  • 10
  • 1.3902
  • 1.6772
  • 1.3934
  • 1.6718
  • 1.4994
  • 1.6568
  • 1.3537
  • .9361 *
  • 2.2254
  • 1.8453
  • 2 2203
  • 1. 8523
  • 2.0633..*.1.8618
  • 2.2686
  • 3.2597 11
  • 1.6718
  • 1.4416
  • 1.6665
  • 1.4544
  • 1.6911
  • 1.4416
  • 1.5048 *

.8204 *

  • 1.8523
  • 2.1468
  • 1.8571
  • 2.1264
  • 1.8245
  • 2.1373
  • 2.0387
  • 3.7118
  • 12
  • 1.4191
  • 1.G729
  • 1.4951
  • 1.6879
  • 1.4533 + 1.6108
  • 1.1331 *

........................ 1.*.1.0200

  • 2.1202
  • 1.9093
  • 2.6988 *
  • 7.: 805
  • 1.8488
  • 2.069 1.6547
  • 1.4394
  • 1.6108
  • 1.1267 *

.8097

  • 13
  • 1.4598
  • 1.4651
  • 2.1156
  • 2.1065
  • 1.8630
  • 2.1405
  • 1.9001
  • 2.7215
  • 3.7596
  • 1.3527
  • 1.5048
  • 1.1331 *

.0086

  • 14
  • 1.1931
  • 1.5347

......................................... 13

  • 3.7596 *
  • 2.5507
  • 2.0037
  • 2.2704
  • 2.0402
  • 2.70 15
  • 1.1588 *

.8921 *

.9361 *

.8193

  • 3.7165
  • M-SUB-Q
  • 2. 5734
  • 3.3647
  • AT 7 5 % POWER, 200 EFPD, THIS Is LEVEL 9 OF 10 (LEVEL 18 s TOP OF CORE, LEVEL 1 BOTTOM)

H G

F E

D C

B A

8

  • 1.2242
  • 1.6306
  • 1.3677
  • 1.6418
  • 1.3934
  • 1.4309
  • 1.1695
  • 1.1331
  • 2.5150
  • 1. 8822
  • 2.2529
  • 1.8786
  • 2.2102
  • 2.1515
  • 2.6236
  • 2.6939
  • 9* 1.6386
  • 1.4169
  • 1.6526
  • 1.4234
  • 1.6461
  • 1.4384
  • 1.5080 *

.8750 *

  • 1.8622
  • 2.1740
  • 1.8666
  • 2.1659
  • 1.8762
  • 2.1436
  • 2.0473
  • 3.4981
  • 10
  • 1.3677
  • 1.6472
  • 1,3709
  • 1.6440
  • 1.4737
  • 1.6322
  • 1.3291 *

.9168 *

  • 2.2529
  • 1.8726
  • 2.249

........................ 4

  • 1.8774
  • 2.0929
  • 1. 8944
  • 2.3228
  • 3.3650.*.

11

  • 1.6418
  • 1.4180
  • 1.6386
  • 1.4330
  • 1.6675
  • 1.4201
  • 1.4812 *

.0054 *

  • 1.8786
  • 2.1740
  • 1.8834
  • 2.1547
  • 1.8559
  • 2.1772
  • 2.0884
  • 3.8307
  • 12
  • 1.3934
  • 1.6440
  • 1.4705
  • 1.6643
  • 1.4351
  • 1.5904
  • 1.1171 *

... 2102

  • 1.8786
  • 2.0909
  • 1.0606
  • 2.1579
  • 1.9476
  • 2.7732 *
  • 2.

........................................................++..

13

  • 1.4309
  • 1.4373
  • 1.6301
  • 1.4191
  • 1.5915
  • 1.1126 *

.7979 *

  • 2.1515
  • 2.1452
  • 1.8969
  • 2.1805
  • 1. 9476
  • 2.7565
  • 3.8899
  • 14
  • 1.1695
  • 1.5058
  • 1.3200
  • 1.4801
  • 1.1160 *

.7968 *

......................................... 59

  • 3.8899 *
  • 2.6236
  • 2.0488
  • 2.3247
  • 2.0899
  • 2.77 15
  • 1.1331

.8729 *

.9157 *

.8054

..................... 3689

  • 3.8387
  • M-SUB-Q
  • 2.6939
  • 3.5065
  • 3

APPENDIX Page 43 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 200 EFPD, THIS IS LEVEL 8 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8

  • 1.2327
  • 1.6675
  • 1.3794
  • 1.6697
  • 1.4052
  • 1.4469
  • 1.1770
  • 1.1481 *
  • 2.4578
  • 1,8189
  • 2.1919
  • 1.799B
  • 2.1

......................... 172

  • 2.0345
  • 2.4599
  • 2.4893
  • 9
  • 1.6675
  • 1.4319 ' i.6815
  • 1.4384
  • 1.6750
  • 1.4533
  • 1.5326 *

.8804 *

  • 1.8189
  • 2.1156 '.1. 8020
  • 2.0974
  • 1.8031
  • 2.0603 '. 1. 9476
  • 3.2524
  • 10
  • 1.3794
  • 1.6761
  • 1.3837
  • 1.6708
  • 1.4919
  • 1.6622
  • 1.3452 *

.9264

  • 2.1919.*. 1.8065
  • 2.1837
  • 1.0110 '.2 0302
  • 1.0245
  • 2.2186
  • 3.1404
  • 11
  • 1.6697
  • 1.4330
  • 1.6665
  • 1.4491
  • 1.7007
  • 1.4384
  • 1.5000 *

.8129 *

.'.................. 1 0166

  • 2. 0959
  • 1. 7965
  • 2.1202..*.2. 0065
  • 3.6423
  • 1.7998
  • 2.1049
  • 12
  • 1.4052
  • 1.6729
  • 1.4865
  • 1.6975
  • 1.4555
  • 1.6215
  • 1.1320 *
  • 2.1172
  • 1.8042
  • 2.0345 '. 1 8009
  • 2.1034
  • 1.890W
  • 2.6988
  • 13
  • 1.4469
  • 1.4523
  • 1.6600
  • 1.4373
  • 1.6226
  • 1.1267 *

.8065 *

  • 2.0345
  • 2.0618 '. 1.8257
  • 2.1218
  • 1.8908
  • 2.7240
  • 3.7840
  • 14
  • 1.1770
  • 1.5315
  • 1.3441
  • 1.5069
  • 1.1310 *

.8065 *

................................. 5.*.2.6988

  • 3.7840 *
  • 2.4599
  • 1.9489
  • 2.2203
  • 2.006 15
  • 1.1481

.8702 *

.9253 *

.8129

  • 2.4893
  • 3.2597
  • 3.

..................... 1438

  • 3.6468
  • M-SUB-Q AT 75% POWER, 200 EFPD, THIS IS LEVEL 7 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8

  • 1.2199
  • 1.6579
  • 1.3677
  • 1.6611
  • 1.3934
  • 1.4351
  • 1.1652
  • 1.1395 *
  • 2.2972
  • 1.6786
  • 1.9996 + 1.6

............................... 289

  • 1 9194
  • 1. 8465
  • 2.2425
  • 2.2686
  • 9
  • 1.6579
  • 1.4201
  • 1.6729
  • 1.4276
  • 1.6665
  • 1.4405
  • 1.5240 *

.8718

  • 1.6786
  • 1.9541
  • 1.6326
  • 1.8969
  • 1.6

........................................ 262

  • 1.8618
  • 1.7543
  • 2 9709
  • 10
  • 1.3677
  • 1.6675
  • 1.3720
  • 1.6633
  • 1.4812
  • 1.6547
  • 1.3355 *.9178 *
  • 1.9996
  • 1. 6372 '.1.9806
  • 1.6301
  • 1.8418
  • 1.6483
  • 2.0065 '. 2.8519
  • 11
  • 1.6611
  • 1.4223
  • 1.6579
  • 1.4394
  • 1.6943
  • 1.4298
  • 1.5005 *

.6054 *

  • 1.6289
  • 1. 9043
  • 1.6427
  • 1.9206
  • 1.6624
  • 1.9541
  • 1.8257
  • 3.3115
  • 12
  • 1.3934
  • 1.6643
  • 1.4758 ' 1.6911 ' 1.4459
  • 1.6161 ' 1.1245
  • 1.*. 1.9726
  • 1. 7554
  • 2 4787
  • 1.9194
  • 1.6280
  • 1.8465
  • 1.667 13
  • 1.4351 1.4405
  • 1.6526
  • 1.4276
  • 1.6161
  • 1.1192 *

.0000 *

  • 1.8465
  • 1.8630
  • 1. 6501..*.1.9554
  • 1.7554 *....................... 1
  • 3.4773
  • 2.529 14
  • 1.1652
  • 1.5230
  • 1.3345
  • 1.5005
  • 1.1235 *

.7990 *

  • 2.2425
  • 1.7564
  • 2.0079
  • 1.8268
  • 2.4008
  • 3.4773
  • 15
  • 1.1395 *

.8697 *.9170 *

.0054

'. 2.2686 *................. 2 8546

  • 2.9710 *

.......... 15

  • M-SUB-Q 3.31

APPENDIX Page 44 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub--Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 200 EFPD, THIS IS LEVEL 6 CF 18 (LEVEL 18. TOP OF CORE, LEVEL 1 x BOTTOM)

H G

F E

D C

B A

8

  • 1.1910
  • 1.6194
  • 1.3377
  • 1.6226
  • 1.3623
  • 1.4030
  • 1.1385
  • 1.1128
  • 2.0735
  • 1.5275
  • 1.8303
  • 1.5069
  • 1.7768
  • 1.7121.*.2.0839
  • 2.1156
  • 9* 1.6194
  • 1. 3 891
  • 1. 6 3 4 3 + 1. 3 9 6 6
  • 1. 62 9 0
  • 1. 4 0 8 4
  • 1. 4 8 98 *

.8514 *

......................................... 1.7202

  • 1.6217
  • 2.7680
  • 1.5275
  • 1.7735
  • 1.5031
  • 1.7470
  • 1.5031
  • 1.3377
  • 1.6290
  • 1.3420
  • 1.6268
  • 1.4480
  • 1.6194
  • 1.3055 *

.8954

  • 10
  • 1 8303
  • 1.5077
  • 1.8211
  • 1 5069
  • 1.6923
  • 1.5179
  • 1.8512
  • 2.6498
  • 1.6226
  • 1.3912
  • 1.6215
  • 1.4084
  • 1.6568
  • 1.3977
  • 1.4673 *

.7861

  • 11
  • 1.5069
  • 1.7533
  • 1.5116
  • 1. 7501.*.1.5077
  • 1.7714
  • 1.6690
  • 3.0485
  • 12
  • 1.3623
  • 1.6268
  • 1.4426
  • 1.6536
  • 1.4148
  • 1.5800
  • 1.0988
  • 1.7768
  • 1.5046 *

................. 2511 *

................. 1.6962

  • 1.5116
  • 1. 7789
  • 1.5899
  • 2.

13

  • 1.4030
  • 1.4073
  • 1.6172
  • 1.3966
  • 1.5819
  • 1.0946 *.7797 *

............. 212

  • 1.5187................ 7724
  • 1.5899 *.............. 2972
  • 3.1711
  • 1.7121
  • 1.7
  • 1 2.

1.1385

  • 1.4887
  • 1.3045
  • 1.4662
  • 1.0978
  • 7797
  • 14
  • 2.0839
  • 1.6226
  • 1.8523
  • 1 6690
  • 2.2529
  • 3.1711
  • 15
  • 1.1128 *

.8493 *

.8943 *

.7861

  • 2.6522
  • 3.0485
  • M-SUB-Q 2.1156 AT 75% POWER, 200 EFPD, THIS IS LEVEL 5 CF 18 (LEVEL 10 = TOP OF CORE. LEVEL 1 = BOTTOM)

F B

A

,,..H.......G...............** E.........D.........C 8* 1.1888

  • 1.6322
  • 1.3388
  • 1.6354
  • 1.3645
  • 1.4105
  • 1.1406
  • 1.1213 *
  • 1.8774
  • 1.3775
  • 1.667
  • 1.3604
  • 1.6253
  • 1.5626
  • 1.9118
  • 1.9334 *

........................ 1................................................

9* 1.6322

  • 1.3912
  • 1.6472
  • 1.3998
  • 1.6418
  • 1.4116
  • 1.5026 *

.8525

  • 1.6083
  • 1.3620
  • 1. 5934
  • 1.3633
  • 1.5694 + 1.4720
  • 2.5435 *
  • 1.3775 +

4,....

10

  • 1.3388
  • 1.6410
  • 1.3441 + 1.6386
  • 1.4512
  • 1.6322
  • 1.3120 *

.8986 *

......... 1.6605.*.1.3665

  • 1.5395
  • 1 3749
  • 1.6844
  • 2.4231 1.6671
  • 1.3658
  • 1.6354
  • 1.3944
  • 1.6333
  • 1.4105
  • 1.6718
  • 1.4030
  • 1.4801 *

.7872

  • 11 *

............................ 2.*.1.3519

  • 1.5977
  • 1 5046
  • 2.7812
  • 1.5995
  • 1.3703
  • 1.568
  • 1.3604 12
  • 1.3645
  • 1.6397
  • 1.4459
  • 1.6675
  • 1.4191
  • 1.5947
  • 1.1021
  • 1.6253
  • 1.3652
  • 1.5436
  • 1.3551
  • 1.5890
  • 1 4162..*. 2.0274 *

.7797

  • 13
  • 1.4105
  • 1.4116
  • 1.6301
  • 1.4009
  • 1.5947
  • 1.0967 1.5626
  • 1.5702
  • 1.3762
  • 1.5995
  • 1.4162
  • 2.0545
  • 2.8519
  • 14
  • 1.1406
  • 1.5015
  • 1.3098
  • 1.4791
  • 1.1021 *

.7797 *

  • 1.9118
  • 1.4735
  • 1.6854
  • 1.5054
  • 2.0288
  • 2.8546
  • 15
  • 1.1213 *

.8504 *

.8986 *

.1872

  • 2.5480
  • 2.4231
  • 2.7J38
  • M-SUB-Q

APPENDIX Page 45 of140 McGuire 2 Cylce 10 Core Operating Limits Report 1Dable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 200 EFPD, THIS IS LEVEL 4 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 r BOTTOM)

H G

F D

...............................E..................C.........B A

8

  • 1.1513
  • 1.5754
  • 1.2981
  • 1.7987
  • 1.5797
  • 1.3238
  • 1.3666
  • 1.1074
  • 1.0828 *

.......... 1.3231 '.1.5960

  • 1.3171..*.1. 5593
  • 1.5007
  • 1.8372
  • 1.8690
  • 9
  • 1.5754
  • 1.3473
  • 1.5915
  • 1.3500
  • 1.5851 1,3666
  • 1.4512 *

.8257 *

  • 1.3231
  • 1.5395
  • 1.3074
  • 1.

.............................. 5259

  • 1. 3118..*.1.5077
  • 1.4176.....................

16 *

  • 2.45 10
  • 1.2981
  • 1.5851
  • 1.3013
  • 1.5829
  • 1.4030
  • 1.5754
  • 1.2691 *

.8686 *

  • 1

... 5960

  • 1.3136
  • 1.5916
  • 1.3136
  • 1.4779
  • 1.3183
  • 1.6181
  • 2.3396
  • 11
  • 1.5797
  • 1.3527
  • 1.5776
  • 1.3655
  • 1.6119
  • 1.3559
  • 1.4287

.7604

  • 1.3171
  • 1.5323 *

................... 1.3171

  • 1.5211
  • 1.2955 *

.......................... 1.5291.....................

90 *

  • 1.4457
  • 2.67 12
  • 1.3238
  • 1.5829
  • 1.3987 ' 1.6086
  • 1.3720
  • 1.5390
  • 1.0646
  • 1 5593
  • 1.3142
  • 1.48

....................... 17

  • 1 2984
  • 1.5163
  • 1.3538
  • 1.9398
  • 13
  • 1.3666
  • 1.3655
  • 1.5744 1.3548
  • 1.5390
  • 1.0592 *

.7518

  • 1.5007
  • 1.5085
  • 1.3

...................... 201......... 07

  • 1.3532
  • 1.9580
  • 2.7342 *
  • 1.53 14
  • 1.1074
  • 1.4501 1.2681
  • 1.4287 ' 1.0635 *

.7518

  • 1.8372
  • 1.4190
  • 1.6199 *

............................ 1.4457

  • 1.9411
  • 2.7342
  • 15
  • 1.0828 *

.8247 *

.8675 *

.7604

  • 1.8690
  • 2.45
  • ............. 58
  • 2. 3414...............

M-SUB-Q 2.6790

  • AT 75% POWER, 200 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 = TCP OF CORE, LEVEL 1 = BOTTCM)

H G

F

...............................E.........D C

B A

8* 1.1224 + 1.5369

  • 1.2691
  • 1.5444
  • 1.2959
  • 1.3388
  • 1.0817 1.
  • 1.0539 *
  • 1.7418

.......... 1.2007

.......... 5420

  • 1.2740
  • 1.5069
  • 1.4507
  • 1 7822
  • 1.0234 9' 1.5369
  • 1.3152
  • 1.5540
  • 1.3302
  • 1.5455
  • 1.3313
  • 1.4126

.0054 *

  • 1.2807
  • 1.4893 *

................... 1.2663

  • 1.4727
  • 1. 2701
  • 1.4638
  • 1.3788
  • 2.3855
  • 10
  • 1.2691
  • 1.5487
  • 1.2734
  • 1.5444
  • 1.3666
  • 1.5315
  • 1.2359 *

.8439 *

  • 1.54

..... 20

  • 1.2707
  • 1.5379
  • 1.2718
  • 1.4322
  • 1.2801
  • 1.r.19
  • 2.2810
  • 11
  • 1.5444
  • 1.3248
  • 1.5390
  • 1.3313
  • 1.5658
  • 1.3173
  • 1.3869 *

.7368 *

. 1.2740

  • 1.4779
  • 1.2757
  • 1.4720.*.1 2570
  • 1.4847
  • 1.4060
  • 2.6165
  • l 12
  • 1.2959
  • 1.5433
  • 1.3623
  • 1.5626
  • 1.3323
  • 1.4930
  • 1.0335
  • t

. 1 5069

  • 2.2734
  • 1 4357
  • 1.2591
  • 1. 4705
  • 1.3142
  • 1.0871 i

13

  • 1.3388
  • 1.3302
  • 1.5294
  • 1.3163 ' 1.4940
  • 1.0271
  • 1

.7261

  • 1.4507
  • 1.4646
  • 1.28

....................... 13 + 1.4862

  • 1.3136
  • 1.9043
  • 2.6692
  • 14
  • 1.0017 1.4116 1.2349
  • 1.3869
  • 1.0324 *

.7261 *

  • 1.7822
  • 1.3794 1.57 1.8883
  • 2.6

...................'.... 36

  • 1.4067 *......................... 717 I

15

  • 1.0539 *

.6043 *

.8439 *

.7368

  • 1.8234
  • 2.3894 2.282

........................ 8

  • 2.6165
  • M-SUB-Q

APPENDIX Page 46 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report 1hable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 200 EFFD, THIS IS LEVEL 2 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

......................F.........E.........D........C H

G B

A

.......................e 8

  • 1.0314
  • 1.3955
  • 1.1631
  • 1.4116
  • 1.1920
  • 1.2156 *

.9832 *

.9296 *

  • 1.8223
  • 1.3538
  • 1.6181
  • 1.3309
  • 1.5761
  • 1 5307......1. 8920
  • 1. 9942
  • 9
  • 1.3955
  • 1.1995
  • 1.4159
  • 1.2274
  • 1.4084
  • 1.2038
  • 1.2531 *

.7315 *

.......... 1.5702

  • 1.3346
  • 1.5339
  • 1. 3407
  • 1.5568
  • 1. 4946
  • 2.5347
  • 1.3538
  • 10
  • 1.1631
  • 1.4105
  • 1.1706
  • 1.3912
  • 1.2434
  • 1.3709
  • 1.1096 *

.7529 *

  • 1.6181
  • 1.3389
  • 1.6003
  • 1.3557 *1
  • 1.3729
  • 1.6854
  • 2.4661 *

....................**.............**. 5124 11

  • 1.4116
  • 1.2231
  • 1.3869
  • 1.2156
  • 1.4126
  • 1.1856
  • 1.2231 *

.6555 *

  • 1.3389
  • 1.5395
  • 1.3595
  • 1.5485
  • 1.3364
  • 1.5856
  • 1.5323
  • 2.8352
  • 12
  • 1.1920
  • 1.4062
  • 1.2402
  • 1.4094
  • 1.2006
  • 1.3205 *

.9211 *

.............................. 3395

  • 1.5677
  • 1.4259
  • 2.0345 *
  • 1.5761
  • 1.3420
  • 1.5163
  • 1 13
  • 1.2156
  • 1.2027
  • 1.3698
  • 1.1845
  • 1.3216 *

.9211

.6447 *

  • 1.5307
  • 1.5576
  • 1.3736
  • 1.5864
  • 1.4252
  • 2.0387
  • 2.8914
  • 14 *

.9832

  • 1.2520
  • 1.1085
  • 1.2231 *

.9211 *

.6447 *

  • 1 8920
  • 1. 4954
  • 1.6864
  • 1 5331.*.2.0359
  • 2.8914 15 *

.9296 *

.7304 *

.7518 *

.6555

  • 1.9942
  • 2.5369
  • 2.4682
  • 2.8352
  • M-SUB-Q AT 75% POWER, 200 EFPD, THIS IS LEVEL 1 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

D C

B A

......................F.......E 8*

.7454 *

.9853 *

.8129

  • 1.0100 *

.8461 *.8322 *

.6833 *

.5923 *

  • 2.4558
  • 1.8642
  • 2. 2563
  • 1.8166
  • 2.1627
  • 2.1886
  • 2.6595
  • 3.0549
  • 9*

.9853 *

.0257

  • 1.0057 *

.8889

  • 1.0110 *

.8086 *

.8482 *

.5098 *

......................................................... 1468

  • 3.5535 *
  • 1.8642
  • 2.2203
  • 1.8257
  • 2.0618
  • 1.8132
  • 2.2581
  • 2 10 *

.8129

  • 1.0014 *

.8236

  • 1.0153 *

.8589 *

.9660 *

.7326 *

.5002 *

.................. 1..*.1.0065

  • 2.1295..*.1. 0920
  • 2.4850
  • 3.6242
  • 2.227
  • 2.2563
  • 1.8337 11
  • 1.0100 *

.8868

  • 1.0121 *

.8429 *

.9960 *.0032 *

.8032 *

.4413 *

  • 1.0166
  • 2.0676
  • 1.8132
  • 2.1740
  • 1.8407
  • 2.2757
  • 2.2704
  • 4.1091
  • 12 *

.8461

  • 1.0089 *

.8579 *

.9939 *

.8172 *.0814 *.6169 *

  • 2.1627
  • 1.8166
  • 2.1358
  • 1.8453
  • 2.2390
  • 2.0750
  • 2.9559
  • 13 *.9322 *

.0075 *

.9660 *.0022 *

.8814 *

.6330 *

.4316 *

  • 2.1886
  • 2.2581
  • 1.8932
  • 2.2775
  • 2.0750
  • 2.8857
  • 4.2099
  • 14 *

.6833 *

.8472 *

.7315 *.8032 *

.6169 *

.4316 *

  • 2.6595
  • 2.1468
  • 2.4872
  • 2.2704
  • 2.9559
  • 4.2099
  • 15 *.5923 *

.5087 *

.4991 *.4413

  • 3.0549
  • 3.5579
  • 3.6207
  • 4.109

................................. 1

  • M-SUB-Q

R I

APPENDIX Page 47 of 140 McGuire 2 Cylce 10 Core Operating Limits Report l'able 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 7 5 % POWER, 405 EFPD, THIS IS LIVEL 18 CF 1B (LEVEL 18 = TCP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.7251

  • 1.0603 *

.9928

  • 1.1888
  • 1.0731
  • 1.0560 *

.9361 *

.8311 *

................................... 1. 8149

  • 2.0435..*.2.2985 *

+ 1.9233

  • 1.6106
  • 1.7858 *
  • 2.2135 '.1.7931 9* 1.0603 *

.9618

  • 1.1508
  • 1.0785
  • 1.1813
  • 1.0110
  • 1.0592 *

.7283 *

............................ 1. 7736

  • 1.6198
  • 1.8909
  • 1.8070 '.2.6225 *

)

  • 1.7931
  • 1.9818
  • 1.6476
  • 10 *

.9928

  • 1.1556
  • 1.0110
  • 1.1588
  • 1.0239
  • 1.1130 *

.9189 *

.7015 *

.......................................... 1

  • 1. 7113
  • 2.0713
  • 2.7119 *
  • 1.9233
  • 1.6520
  • 1.8861
  • 1.6461
  • 1.862...........................

11

  • 1.1888
  • 1.0785
  • 1.1567 *

.9800

  • 1.0367 *

.8911 *

.9275 *

.5976 *

  • 1.6106
  • 1.7748
  • 1.6492
  • 1.9380
  • 1.8234
  • 2.1156
  • 2.0380
  • 3.1572
  • 12
  • 1.0731
  • 1.1824
  • 1.0228
  • 1.0357 *

.7186 *

.8065 *

.6887 *

............................ 1. 8259

  • 2.0713
  • 2.0016
  • 2.6858 *
  • 1.785B
  • 1.6198
  • 1.8634
  • 13
  • 1.0560
  • 1.0100
  • 1.1128 *

.9911 *

.8065 *

.5858 *

.4927

  • 1.8149
  • 1.8909
  • 1.7113
  • 2.1156
  • 2.0016
  • 2.5902
  • 3.5166
  • 14 *

.9361

  • 1.0501 *

.9189 *

.9275 *

.6887 *

.4927 *

  • 2.0435
  • 1.8083
  • 2.0713
  • 2. 0300
  • 2 6858
  • 3.5166
  • 15 *

.8311

  • 7272 *

.7004 *

.5976

  • 2.7131
  • 3.1590
  • M-SUB-Q
  • 2.2985 '.2.6251 AT 75% POWER, 405 EFPD, THIS IS LEVEL 17 0F 18 (LEVEL 18 a TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D A

.................................................C.........B.............**

8*

.8579

  • 1.3227
  • 1.2391
  • 1.4737
  • 1.3323
  • 1.3366
  • 1.1738
  • 1.1117 *
  • 1.8958
  • 1.4845
  • 1.5898
  • 1.3399
  • 1.4819
  • 1.4770
  • 1.6807
  • 1.7725
  • 9* 1.3227
  • 1.2134
  • 1.4405
  • 1.3216
  • 1.4641
  • 1.3120
  • 1.3527 *

.9136 *

.................................................. 2. 1562

  • 1.3487
  • 1.5014
  • 1.4569
  • 1.3670
  • 1.4924
  • 1.4845
  • 1./

94 10

  • 1.2391
  • 1.4373
  • 1.2734
  • 1.4100
  • 1.3066
  • 1.3977
  • 1.2081 *

.9146 *

)

  • 1.5898
  • 1.3704
  • 1. 5440
  • 1.3875
  • 1.5045
  • 1.4084
  • 1.6253
  • 2.1466 *

)

11

  • 1.4737
  • 1.3205
  • 1.4169 ' 1.2477
  • 1.3130
  • 1.1503
  • 1.2295 *

.7743 *

.........'.................. 1.5699

  • 1.4895
  • 1.6886
  • 1.5827
  • 2 5119 *
  • 1.3399 1.4933
  • 1.3897
  • 12
  • 1.3323 ' 1.4641
  • 1.3055
  • 1.3120 *

.8804

  • 1.0485 *

.8921

  • l
  • 1.4819 *
  • 1.5058
  • 1.4915
  • 1.7098
  • 1.6020
  • 2.1375 *

.......... 1 3484 13

  • 1.3366
  • 1.3120
  • 1.3966
  • 1.1492 + 1.0485 *

.7636 *

.6426 *

)

.................,..................................... 2 7684 *

  • 1.4770
  • 1.5014
  • 1.4007 1.6891
  • 1.6020
  • 2.1009
  • 14 ' 1.1738
  • 1.3516
  • 1.2070
  • 1.2295 *

.8921 *

.6415

  • i
  • 1.6807 '.1.4572
  • 1.6262 '.1.5827
  • 2.1375
  • 2.7684 *

....................e 15

  • 1.1117

.9114 *

.9146

  • 7733
  • 2.1596
  • 2.1466
  • 2.5119
  • M-SUB-Q

APPENDIX Page 48 of 140 McGuire 2 Cylce 10 Core Operating Limits Report lnable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 405 EFPD, Ti!IS IS LEVEL 16 OF 10 (LEVEL 18 = TCP OF CORE, LEVEL 1 3 BOTTOM)

................**..............................C...**....B H

G F

E D

A 8*

.9146

  • 1.4244
  • 1.3002
  • 1.5904
  • 1.4009
  • 1.4169
  • 1.2263
  • 1.1952 *

................... 1.5665

  • 1. 2000
  • 1.4532
  • 1.4366
  • 1.6626
  • 1.7035..*.
  • 1.8400
  • 1.4287
  • 9* 1.4244
  • 1.2009
  • 1.5540
  • 1.3923
  • 1.5797
  • 1.3955
  • 1.4600 *

.9564 *

........................ 6...*.1.4609

  • 1.2874
  • 1 4532.*. 1.3898
  • 2 1297 *
  • 1.4287
  • 1.5889
  • 1.309 10
  • 1.3002
  • 1.5508
  • 1.3441
  • 1.5326
  • 1.3923
  • 1.5090
  • 1.2884 *

.9757 *

................................. 1

  • 1.4543
  • 1.3420
  • 1 5687
  • 2.0755 *
  • 1.5665
  • 1.3124
  • 1.5130
  • 1.325....................................

11

  • 1.5904
  • 1.3912
  • 1.5305
  • 1.3238
  • 1.4191
  • 1.2252
  • 1.3323 *

.8225 *

.................. 322.*.1 5022

  • 2.4294 *

.............. 17

  • 1.3268
  • 1 5298
  • 1.4234
  • 1.6 1.2008
  • 1.46 12
  • 1.4009
  • 1.5808
  • 1.3912
  • 1.4169 *

.9478

  • 1.1342 *

.9532 *

............... 1

  • 1. 4558
  • 1. 4240
  • 1. 6643
  • 1 5356
  • 2.0421
  • 1.4532
  • 1.287 13
  • 1.4169
  • 1.3955
  • 1.5090
  • 1.2252
  • 1.1342 *

.8161 *

.6844 *

...............32..*.1. 3423.*. 1. 6332

  • 3.5356
  • 2.0422
  • 2 6666 *
  • 1.4366
  • 1.45 14
  • 1.2263
  • 1.4600
  • 1.2873
  • 1.3323 *.9521 *

.6844 *

................... 1.5691

  • 1.5022
  • 2.0436
  • 2 6672 *
  • 1.6626
  • 1.3905
  • 15
  • 1.1952 *

.9553 *

.9757 *

.8225

  • 2.13
  • 2.0763
  • 2.4315
  • M-SUB-Q

.............c.21

....**.+.........**..

AT 75% POWER, 405 EFPD, THIS IS LEVEL 15 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 BOTTCM)

H G

F E

D C

B A

8*

.9243

  • 1.4469
  • 1.2991
  • 1.6172
  • 1.4009
  • 1.4201
  • 1.2167
  • 1.2017
  • 1.7806
  • 1.4433
  • 1.6320
  • 1.3056 1.5047
  • 1.4830
  • 1.7374
  • 1.7559
  • 9
  • 1.4469
  • 1.2852
  • 1.5008
  • 1.3966
  • 1.6054
  • 1.3998
  • 1.4791 *.9510 *

.............. 15

  • 1.3384 '.1.5105
  • 1 3105
  • 1 4979
  • 1. 4187
  • 2.2210
  • 1.4433
  • 1.65 10
  • 1.2991
  • 1.5765
  • 1.3484
  • 1.5626
  • 1.4019
  • 1.5203
  • 1.2916 *

.9768 *

  • ..........**................. 3475
  • 1.4954
  • 1.3604
  • 1.6150
  • 2.1405 *
  • 1.6320
  • 1.3413
  • 1.5691
  • 1...........................................

11

  • 1.6172
  • 1.3955
  • 1.5583
  • 1.3323
  • 1.4405
  • 1.2327 + 1.3495 *.8225 *

............. 1 4282

  • 1.6692
  • 1.5348
  • 2.5113 *
  • 1.5781 *
  • 1.3056
  • 1.5111 1.35

....................... 11 12

  • 1.4009
  • 1.6054
  • 1.4009
  • 1.4384 *

.9596

  • 1.1524 *

.9505

  • 1.5047
  • 1.3105
  • 1.4970
  • 1.4296
  • 1.6523
  • 1.5128
  • 2.0525
  • 13
  • 1.4201
  • 1.3998
  • 1.5203
  • 1.2327
  • 1.1524 *.8236 *.6876 *
  • 1.4830
  • 1.4973
  • 1 3604
  • 1.6694
  • 1.5126
  • 2.0344
  • 2.6745
  • 14
  • 1.2167
  • 1.4780
  • 1.2916
  • 1.3484 *.9505 *

.6d76 *

.................................*....... 36

  • 2.6765 *
  • 1.7374
  • 1.4193
  • 1.6159
  • 1.5348
  • 2.05 15
  • 1.2017 *

.9489 *

.9768 *

.8225

  • 1.7559
  • 2.2237
  • 2.1409
  • 2.5113
  • M-SUD-Q

APPENDIX Page 49 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations 1

AT 75% POWER, 405 EFFD, THIS IS LEVEL 14 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.8975

  • 1.4052
  • 1.2552
  • 1.5701
  • 1.3516
  • 1.3687 1.1674
  • 1.1567 *
  • 1.9048
  • 1.538 1.*. 1 7679
  • 1. 405? *.1.6319
  • 1 6076
  • 1 8005
  • 1.8929
  • 9*

1.4052 ' 1.2445

  • 1.5350
  • 1.3516
  • 1.5572 ' 1.3516 ' 1.4298 *.9114 *

.................................. 260

  • 1. 5319
  • 2.4029 *
  • 1.5381
  • 1.77 1.4406
  • 1.6340
  • 1.4122
  • 1.6

.............. 18

  • 10
  • 1.2552
  • 1.5326
  • 1.3055
  • 1.5187
  • 1.3580
  • 1.4801 a 1.2456 *

.9393 *

  • 1.7679
  • 1.4441 *

................... 1.6966 *

.............................. 16..*.1.7568

  • 2 3235..*.

1.4514

  • 1.6219
  • 1.48 11
  • 1.5701
  • 1.3505
  • 1.5155
  • 1.2927
  • 1.3907
  • 1.1931
  • 1.3055 *

.7936 *

  • 1.4052
  • 1.6349
  • 1.4550
  • 1.7101
  • 1.5218
  • 1.7689
  • 1.6753
  • 2.7442
  • 12
  • 1.3516
  • 1.5572
  • 1.3559 ' 1.3966 *

.9328

  • 1.1192 '

.9275 *

  • 1.6319
  • 1.4128
  • 1. 6238
  • 1.5236
  • 1.7636
  • 1. 6130
  • 2.2029
  • 1.3516
  • 1.4801
  • 1.1931
  • 1.1192 *

.8000

.6672

  • 13
  • 1.3687 *

.......... 1. 6260

  • 1.4816
  • 1 7892
  • 1. 6128
  • 2. 1744
  • 2.8668 *
  • 1.6076
  • 1.4287
  • 1.2456
  • 1.3055 *

.9275 *

.6672

  • 14
  • 1.1674

.............. 27 1.7560

  • 1.6753
  • 2.2029
  • 2.8697
  • 1.8005
  • 1.53 15
  • 1.1567

.9104

.9393 *

.7925

.............................. 7442

  • M-SUH-Q
  • 1.0929
  • 2.4066
  • 2.3254
  • 2 AT 75% POWER.

405 EFPD, THIS IS LEVEL 13 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.9007

  • 1.4212 ' 1.2531
  • 1.5819
  • 1.3462
  • 1.3655
  • 1.1578
  • 1.1578 *
  • 1. 9557
  • 1. 5859
  • 1.8877
  • 1.4938
  • 1. 7538
  • 1 7221
  • 2 0188
  • 2.0004
  • 9
  • 1.4212
  • 1.2466
  • 1.5508
  • 1.3495
  • 1.5701
  • 1.3473
  • 1.4362 *.9061
  • 1.5859 *

.......... 17

  • 1.7541
  • 1.5025
  • 1.7473
  • 1.6305
  • 2.5700
  • 1.53..........................**.........**.........

.......... 1. 0440

  • 10
  • 1.2531 1.5476
  • 1.3055
  • 1.5358
  • 1.3591
  • 1.4919
  • 1.2456 *.9382 *

. 1. 8877

  • 1 5358
  • 1.8200
  • 1 5431
  • 1 7433
  • 1.5004
  • 1.8854
  • 2.4866
  • 11 ' 1.5819 ' 1.3484
  • 1.5326
  • 1.2970
  • 1.4126
  • 1.1984
  • 1.3173
  • 7936
  • 1.4938
  • 1.7551
  • 1.5473
  • 1.7990
  • 1.5805 ' 1.8712
  • 1.7786
  • 2.9554
  • 12
  • 1.3462
  • 1.5690
  • 1.3560
  • 1.4116 *

.9393

  • 1.15..

.9371 *

  • 1.7538
  • 1.5033 '.1.7454 '.1.5822
  • 1.8571..*.1.6909
  • 2.3075
  • 13
  • 1.3655
  • 1.3473
  • 1.4919
  • 1.1984
  • 1.1363 *

.8129 *

.6769 *

  • 1.7221
  • 1.7473 1.5004

...................'......................................0259*

1.8712

  • 1.6906
  • 2.2987
  • 3.

14

  • 1.1578
  • 1.4362
  • 1.2445 ' 1.3173 *

.9371 *

.6769 *

  • 2.0100
  • 1.6314

............................ 1 7786

  • 2. 3000 '. 3.0281.*.
  • 1.8866
  • 15
  • 1.1578 '

.9050 *

.9302 *

.7936

  • 2.0084 *

..................'...................2.4883

  • 2.9560
  • M-SUB-Q

i i

APPENDIX Page 50 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report 1hable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% PohER, 405 EFFD, THIS IS LEVEL 12 CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

...................................................................A......

H G

F E

D C

B 8*

.9157

  • 1.4266
  • 1.2424
  • 1.5658
  • 1.3238
  • 1.3409
  • 1.1353
  • 1.1374 *
  • 2.0947
  • 1. 6960
  • 2.0261
  • 1. 6390
  • 1.9329
  • 1.8950
  • 2.2200.*. 2.1975
  • 9
  • 1.4266
  • 1.2402
  • 1.5412
  • 1.3334
  • 1.5551
  • 1.3270
  • 1.4169 *

.8900 *

  • 1.6960
  • 1.9770
  • 1.6718
  • 1.9329
  • 1.6496
  • 1.9273
  • 1. 7881
  • 2.8197 10 ' 1.2424
  • 1.5380
  • 1.2916
  • 1.5203
  • 1.3452
  • 1.4823
  • 1.2295 *

.9243 *

  • 2.0261
  • 1.6757
  • 1.9927
  • 1. 6763
  • 1.9062
  • 1.7261
  • 2.0762
  • 2. 7321
  • 11
  • 1.5658
  • 1.3302
  • 1.5240
  • 1.2927
  • 1.4169 ' 1.2006
  • 1.3141 *

.7861 *

................... 1. 6818

  • 1.9306
  • 1.6879
  • 2.0039 *.................................... 042
  • 3.2532
  • 1.9
  • 1.6390
  • 1.9332
  • 12
  • 1.3238
  • 1.5551
  • 1.3441
  • 1.4148 *

.9628

  • 1.1631 *

.9478 *

  • 1.9329
  • 1.6504
  • 1.9075
  • 1.6899
  • 1.9830
  • 1.7990
  • 2.4654
  • 13
  • 1.3409
  • 1.3270
  • 1.4823
  • 1.2006
  • 1.1642 *

.8418 *

.6919 *

.........'.**............................................. 268 *

  • 1.8950 1.9273
  • 1.7261
  • 2.0049
  • 1.7990
  • 2.4466
  • 3.2 14
  • 1.1353
  • 1.4169
  • 1.2295
  • 1.3141 *

.9468 *

.6919

  • 2.0765
  • 1.9034
  • 2.4654
  • 3.2268 *
  • 2.2208
  • 1. 7891

.8889 *

.9243 *

.7861

  • 1.1374
  • 2.1975
  • 2.8252
  • 2.7321
  • 3.2532
  • M-SUB-Q AT 75% POWER, 405 EFPD, THIS IS LEVEL 11 0F 18 (LEVEL 18 = TCP OF CORE, LEVEL 1 = BOT
  • TOM)

H G

E D

B A

......................F...........................C........................

8

  • 1.0078
  • 1.4512
  • 1.2456
  • 1.5476
  • 1.3034
  • 1.3184
  • 1.1149
  • 1.1181 *
  • 2.2768
  • 1.8280
  • 2.1894
  • 1.7997
  • 2. 1423
  • 2.0985
  • 2.4523
  • 2.4194
  • 1.3098
  • 1.3987 *

.8739

  • 9
  • 1.4512
  • 1.2541 + 1.5326
  • 1.3205
  • 1.5401
  • 1.8280
  • 2.1349
  • 1.0008
  • 2.0977
  • 1.8006
  • 2.1189
  • 1.9732
  • 3.1130.*.

......+................................**..............................

1.2920

  • 1.5208
  • 1.3366
  • 1.4748
  • 1.2177 *

.9114

  • 10
  • 1.2456
  • 1.5294
  • 2.1894
  • 1.0053
  • 2 1552
  • 1.0040 '.2.0562
  • 1.8567
  • 2.2635
  • 3.0171.*.

11

  • 1.5476
  • 1.3173
  • 1,5165
  • 1.2981
  • 1.4373
  • 1.2188
  • 1.3184 *

.7818 *

  • 1.7997
  • 2.1023
  • 1.8097
  • 2.0856
  • 1.8254
  • 2.1707
  • 2.0471
  • 3.4967
  • 12
  • 1.3034
  • 1.5390
  • 1.3345
  • 1.4351
  • 1.0731
  • 1.2488 *.9735 *

..................................... 2.1467

  • 1.9424
  • 2.6656 *
  • 2.1423
  • 1.8018
  • 2.0576
  • 1.8276
  • 13
  • 1.3184
  • 1.3098
  • 1.4748
  • 1.2188 ' 1.2488 *

.9146 *

.7219 *

  • 2.0985
  • 2.1188
  • 1. 8567
  • 2.1709
  • 1 9415
  • 2.6422
  • 3.4876
  • 14
  • 1.1149
  • 1.3977
  • 1.2177
  • 1.3184 *

.9735 *

.7219 *

  • 2.4523
  • 1.9743 2.2652
  • 2.0471
  • 2.6673
  • 3.4876
  • 15
  • 1.1181

.8729 *

.9114 *

.7818

  • 2.4194
  • 3.1190 3.0171
  • 3.4967
  • M-SUB-Q

l APPENDIX Page51of140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 405 EFFD, THIS IS LEVEL 10 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

H G

D C

B A

......................F........E 8* 1.1310

  • 1.5208
  • 1.2745
  • 1.5701
  • 1.3109
  • 1.3280
  • 1.1203
  • 1.1299 *

..................... 3217

  • 1.9181
  • 2.3045
  • 2.2775
  • 2 6719
  • 2.6127 *
  • 2.4034
  • 1.9424
  • 2.

9

  • 1.5208
  • 1.2948
  • 1.5626
  • 1.3366
  • 1.5647
  • 1.3227
  • 1.4180 *

.8804 *

.................................................................. 3771 *

  • 1.9424
  • 2.2793
  • 1.9168
  • 2.2459
  • 1.9181
  • 2.2704
  • 2.1156
  • 3.

10

  • 1.2745
  • 1.5594
  • 1.3013
  • 1.5540
  • 1.3580
  • 1.5080
  • 1.2370 *

.922.. *

.......................................................... 151..*.

3.2561 *

  • 2.3217
  • 1.9219
  • 2.2856
  • 1.9168
  • 2.2002
  • 1.9739
  • 2.4..

11

  • 1.5701
  • 1.3345
  • 1.5497
  • 1.3313
  • 1.5000
  • 1.2638
  • 1.3591 *

.7968 *

  • 1. 9181
  • 2.2511
  • 1.9232
  • 2.2271
  • 1.9346
  • 2.3099
  • 2.1691..*.3.7260
  • 1.3570
  • 1.5058
  • 1.2434
  • 1.3816
  • 1.0228
  • 12
  • 1.3109
  • 1.5647

............**.............. 1.9372

  • 2.2900
  • 2 0603
  • 2.8270..*
  • 2.3045
  • 1.9194
  • 2.2018 *...............................

13

  • 1.3200
  • 1.3227
  • 1.5000
  • 1.2638
  • 1.3816
  • 1.0035 *

.7700 *

................... 1.9739

  • 2.3099
  • 2.0589
  • 2.8106
  • 3.7023
  • 2.2775
  • 2.2704
  • 14
  • 1.1203
  • 1.4100
  • 1.2359
  • 1.3591
  • 1.0228 *

.7690 *

...................... 151..*.2. 1691

  • 2.8270
  • 3.7070 *
  • 2.6719
  • 2.1156
  • 2.4 15
  • 1.1299 *

.8793 *

.9221 *

.7968

  • F-SUB Q
  • 2.6127
  • 3.3810
  • 3.2561
  • 3.7260
  • M-SUB-Q AT 75% POWER, 405 EFFD, THIS IS LEVEL 9 0F 18 (LEVEL 18. TOP OF CORE, LEVEL 1 = DOTTOM)

H G

F E

D C

B A

8

  • 1.1438
  • 1.5187
  • 1.2649
  • 1.5444
  • 1.2884
  • 1.3034
  • 1.0908
  • 1.1085 *

.......................................... 2

  • 2.3777
  • 2.8188
  • 2.7865 *
  • 2.5157
  • 2.0218
  • 2.4288
  • 2.0024
  • 2.401.............................
  • 1.5107
  • 1.2959
  • 1.5433
  • 1.3195
  • 1.5412
  • 1.3023
  • 1.3955 *.8643
  • 2.0218
  • 2.3661
  • 1.9996
  • 2.3396
  • 2.0051
  • 2.3758
  • 2.2220
  • 3.5885
  • 10
  • 1.2649
  • 1.5390
  • 1.2852
  • 1.5300
  • 1.3430
  • 1.4908
  • 1.2209 *

.9082 *

  • 3.4242 *
  • 2.4288
  • 2.0037
  • 2.3973
  • 2.0037
  • 2.2954
  • 2.0706
  • 2.5347 11
  • 1.5444
  • 1.3163
  • 1.5337
  • 1.3248
  • 1.5123
  • 1.2681
  • 1.3527 *

.7893 *

  • 2.0024
  • 2.3433 + 2.0106
  • 2.3210
  • 2.0274
  • 2.4191
  • 2.2793
  • 3.9213 *

......................e.................................................*

12

  • 1.2884
  • 1.5412
  • 1.3420
  • 1.5112
  • 1.2723
  • 1.4105
  • 1.0314 *
  • 2.4012
  • 2.0065
  • 2.2972
  • 2.0302
  • 2.3953
  • 2.1611
  • 2.9739
  • 13
  • 1.3034
  • 1.3023
  • 1.4909
  • 1.2681
  • 1.4116
  • 1.0292 *

.7829

  • 2.9559
  • 3.9003 *

... 3777

  • 2.3738
  • 2.0706
  • 2.4191 + 2.1611
  • 2.............................................................

1.0988

  • 1.3955
  • 1.2209
  • 1.3527
  • 1.0314 *

.7829

  • 14
  • 2. 8160
  • 2.2237
  • 2.5347
  • 2.2775
  • 2.9739
  • 3.9003
  • 15
  • 1.1085 *

.8632 *

.9082 *

.7893

  • 2.7865
  • 3.5929
  • 3.4242
  • 3.9213
  • M-SUB-Q

APPENDIX Page 52 of 140 McGuire 2 Cylce 10 Core Operating Limits Report l

1rable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations j

AT 75% POWER, 405 EFPD, THIS IS LEVEL 8 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H

.............G...........................D...........................A F

E C

B 8

  • 1.1631
  • 1.5530
  • 1.2820
  • 1.5722
  • 1.3013
  • 1.3205
  • 1.1085
  • 1 1267 *
  • 2.3579
  • 1.919

............... 4...*.2.2795

  • 1.8957......................22
  • 2.2288
  • 2.6274
  • 2.5724...*
  • 2.27 9
  • 1.5530
  • 1.3173
  • 1.5722
  • 1.3366
  • 1.5701
  • 1.3184
  • 1.4212 *

.8750 *

. 1.9194

  • 2.2494.................
1. 8969
  • 2.2203
  • 1. 8969
  • 2. 2356
  • 2.0720
  • 3.3176
  • 1.2820
  • 1.5679
  • 1.3023
  • 1.5722
  • 1.3623
  • 1.5230
  • 1.2411
  • 2.279

...... 5

  • 1.9019............2.2460
  • 1 8994

.9211 *

.......2.1740

  • 1.9489
  • 2.3681 *.........................*.3.1506 11
  • 1.5722
  • 1.3334
  • 1.5669
  • 1.3473
  • 1.5530
  • 1.2948
  • 1.3859
  • 1.89
  • ..... 57
  • 2,2237 *

.8032 *

............. 1.9043

  • 2.2002..*.1.9156
  • 2.2793
  • 2.1233
  • 3 6152
  • 12
  • 1.3013
  • 1.5690
  • 1.3612
  • 1.5508
  • 1.3055
  • 1.4555
  • 1.0581 *

. 2.2722 *.........1.8981

  • 2.1756
  • 1.918

..................... 1

  • 2.258

........ 1

  • 2.0232
  • 2.7653
  • 13
  • 1.3205
  • 1.3195
  • 1.5230
  • 1.2948
  • 1.4566
  • 1.0614 *
  • 2.2288
  • 2.2356
  • 1.9489
  • 2.2793
  • 2.0232
  • 2.7471
  • 3.5973

.8054 14

  • 1.1085
  • 1.4212
  • 1.2402
  • 1.3859
  • 1.0581 *

.8054 *

  • 2.6

.... 274

  • 2. 0720
  • 2.3681
  • 2.1

.................. 233...*.2.7653

  • 3.5973
  • 15
  • 1.1267

.8739

.9211

  • 2.57

.6032

..... 24

  • 3.3213
  • 3.1506
  • 3.6152
  • M-SUB-Q AT 75% POWER, 405 EFPD, THIS IS LEVEL 7 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 c DOTTOM)
  • ...H..................F...........................C G

E D

B A

8

  • 1.1588
  • 1.5519
  • 1.2766 + 1.5701
  • 1.2948
  • 1.3163
  • 1.1031
  • 1.1245
  • i
  • 2.

... 1043

  • 1.7091
  • 2.035

.....................3

  • 1.6892
  • 2.0275
  • 1.9840
  • 2.3415
  • 2.2892
  • 9
  • 1.5519
  • 1.3141
  • 1.5701
  • 1.3323...............................................

1.7C9

  • 1.5690
  • 1.3141
  • 1.4212 *

.8718 *

.'..... 1

  • 2.0079
  • 1.6901
  • 1.9812
  • 1.6893
  • 1.9965
  • 1.8461

.........................................................*.2.9568 10

  • 1.2766
  • 1.5669
  • 1.2981
  • 1.5733
  • 1.3591
  • 1.5240
  • 1.2391

. 2.0353

  • 1.6940
  • 2.0034..*.1.6892
  • 1.9406
  • 1.7346
  • 2.1135
  • 2.8161 *

.9189

  • 11
  • 1.5701 1.3291
  • 1.5679
  • 1.3452
  • 1.5562
  • 1.2948
  • 1.3891
  • 1.

... 6892

  • 1.9852
  • 1.6942
  • 1.9620
  • 1.7031
  • 2.0302
  • 1.8895
  • 3.2331

.8022

  • 12
  • 1.2948
  • 1.5679
  • 1.3570
  • 1.5551
  • 1.3077
  • 1.4630
  • 1.0614 *
  • 2.0

.... 275

  • 1.6902
  • 1.9431
  • 1.7051................................

2.0120

  • 1.7998
  • 2.4641 13
  • 1.3163
  • 1.3141
  • 1.5240
  • 1.2948
  • 1.4641
  • 1.9840
  • 1.1965
  • 1.7 1.0656 *.8086 *

+

.......................346* 2.0316

  • 1.7987......................

2.4496

  • 3.2095
  • 14
  • 1.1031
  • 1.4212
  • 1.2391
  • 1.3891
  • 1.0614 *

.8086

  • 2.3
  • .....415
  • 1.8466
  • 2.1135
  • 1.8895
  • 2.4641

........................................*.3.2095 15

  • 1.1245 *

.8707 *

.9189 *. 8 0 3 2

  • 2.2892
  • 2.9598 *

................... 2.8161

  • 3.2297
  • M-SUB-Q

APPENDlX Page 53 of 140 McGuire 2 Cylce 10 Core Operating Limits Report l'able 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 405 EFFD, THIS IS LEVEL 6 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

E D

C B

A

....H.........G.........F...................................................

8

  • 1.1406
  • 1.5283
  • 1.2574
  • 1.5465
  • 1.2756
  • 1.2959
  • 1.0881
  • 1.1085 *

. 1. 9310 *...... 1.5511

  • 1.8604
  • 1.5268
  • 1.9343 '.1.7982
  • 2.1239
  • 2 0822
  • 9
  • 1.5283
  • 1.2948
  • 1.5476
  • 1.3130
  • 1.5455
  • 1.2948
  • 1.4009 *

.8599 *

.........'.... 18

  • 1.5300.*. 1 7915
  • 1.5278
  • 1. 8071
  • 1.6692
  • 2 6873 *
  • 1.5511 1.82 10
  • 1.2574
  • 1.5433
  • 1.2788
  • 1.5508
  • 1.3398
  • 1.5037
  • 1.2220 *

.9061 *

..................... 8292

  • 1 5305
  • 1.7585
  • 1 5714
  • 1.9140
  • 2.5535
  • 1.8604
  • 1.5335 + 1 11
  • 1.5465
  • 1.3109
  • 1.5465
  • 1.3270
  • 1.5'69
  • 1.2788
  • 1.3720 *

.7925 *

  • 1.5268
  • 1.7954
  • 1.5353
  • 1.7782
  • 1.243 1.8412
  • 1.7142
  • 2.9363
  • 12
  • 1.2756
  • 1.5455
  • 1.3377
  • 1.5347
  • 1.2927
  • 1.4480
  • 1.0496 *
  • 1.8343
  • 1.5281
  • 1.7596
  • 1. 5447
  • 1.8239
  • 1.6310
  • 2.2365
  • 13
  • 1.2959
  • 1.2948
  • 1.5037
  • 1.2788 ' 1.4480 ' 1,0549 *

.0000 *

..................'..................... 301

  • 2.2231
  • 2.9187
  • 1.7982
  • 1.8064 1.5714
  • 1.8412
  • 1.6 14
  • 1.0881
  • 1.4009
  • 1.2220
  • 1.3720
  • 1.0485 *.8000
  • 2.*. 1 9140.*.1. 7132.*.2. 2365
  • 2.9187
  • 2.1239
  • 1.670 15
  • 1.1085 *

.8579 *

.9061 *.7925 ' F-SUB-Q

  • 2.0822
  • 2 6698
  • 2.5535.*.2.9362
  • M-SUB-Q AT 75% POWER, 405 F.FPD, THIS IS LEVEL 5 0F 18 (LEVEL 18 = TCP CF CORE, LEVEL 1
  • BOTTOM) d C

F E

D C

B A

8

  • 1.1513
  • 1.5540
  • 1.2713
  • 1.5733
  • 1.2906
  • 1.3173
  • 1.1031
  • 1.1310 *
  • 1.704B
  • 1.3737
  • 1.6416
  • 1.3545
  • 1.6382 '.1.6002
  • 1 8997 '. 1.8524
  • 9
  • 1.5540
  • 1.3088
  • 1.5733
  • 1.3302
  • 1.5744
  • 1.3120
  • 1.4298 *

.9729 *

'.1. 3737

  • 1.6225
  • 1.3554
  • 1. 5954
  • 1.3534
  • 1. 6100
  • 1. 4006
  • 2. '998
  • 10
  • 1.2713
  • 1.5701
  • 1.2948
  • 1.5808
  • 1.3570
  • 1.5326
  • 1.2424 *

.9221 *

  • 1.6416
  • 1.3527
  • 1. 6131
  • 1.3524
  • 1.5634.*. 1. 3888
  • 1. 7009
  • 2. 2751
  • 11 ' 1.5733
  • 1.3270
  • 1.5754 ' '.3452
  • 1.5669
  • 1.2981
  • 1.3998 *

.8043 *

  • 1.3545
  • 1. 5999
  • 1. 3568
  • 1 5806
  • 1.3652
  • 1.6368
  • 1 5158
  • 2. 6141
  • 12
  • 1.2906
  • 1.5744
  • 1.3559
  • 1.5547
  • 1.3120
  • 1.4780
  • 1.0678 *
  • 1.6302
  • 1.3540
  • 1.5650
  • 1.3665
  • 1.6237
  • 1.4463
  • 1.9903
  • 13
  • 1.3173
  • 1.3130
  • 1.5326
  • 1.2961
  • 1.4791
  • 1.0721 *

.8129 *

..................................... 1. 4458

  • 1.9932
  • 2.6065 *
  • 1.6002
  • 1.6094
  • 1.3888
  • 1.636i 14
  • 1.1031
  • 1.4298
  • 1.2424
  • 1.3998
  • 1.0678 *

.8129

  • 1.0997
  • 1.4811 1.7009
  • 1.5158
  • 1.9911
  • 2.6065
  • 15
  • 1.1310 *

.8718 *.9221 *.8043

  • 1.8524
  • 2.4031
  • 2.2751
  • 2.6132
  • M-SUB-Q j

APPENDIX Page 54 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 405 EFPD, THIS IS LEVEL 4 OF 18 (LEVEL 18 m 10P CF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8* 1.1320

  • 1.5272
  • 1.2520
  • 1.5487
  • 1.2745
  • 1.2991
  • 1.0924
  • 1.1171 *

.... 163..*.1.2829

  • 1. 5515
  • 1. 2648
  • 1.5270
  • 1.4942..*.1 7693..*.1. 7333
  • 1.6 9* 1.5272
  • 1.2884
  • 1.5476
  • 1.3130
  • 1.5500
  • 1.2959
  • 1.4126 *

.8632 *

  • 1.2829
  • 1.5138
  • 1.2659
  • 1.4854
  • 1.2626
  • 1.4998
  • 1.3809
  • 2.2421
  • 10
  • 1.2520
  • 1.5444
  • 1.2766
  • 1.5562
  • 1.3388
  • 1.5123
  • 1.2284 *

.9114 *

  • 1. 5515
  • 1. 2689
  • 1. 5234
  • 1.2611.*. 1.4566
  • 1.2933.*. 1. 5830
  • 2.1251 11
  • 1.5487
  • 1.3109
  • 1.5508
  • 1.3270
  • 1.5455
  • 1.2831
  • 1.3827 *

.7958 *

....................................... 2669

  • 1.5199
  • 1.4109
  • 2.4384 *
  • 1.2648
  • 1.4884
  • 1.2649
  • 1.4706 1.

12

  • 1.2745
  • 1.5508
  • 1.3377
  • 1.5433
  • 1.2970
  • 1.4598
  • 1.0549
  • 1.8492 *

................... 1.4573

  • 1.2704
  • 1.5060
  • 1. 3418
  • 1.5270
  • 1.2631 13
  • 1.2991
  • 1.2970
  • 1.5133
  • 1.2831
  • 1.4608
  • 1.0603 *

.0032

  • 2..*. 1. 8418
  • 2.4255 *
  • 1.341

... 4942

  • 1.4995
  • 1 2933
  • 1. 519)
  • 1 14
  • 1.0924
  • 1.4116
  • 1.2284
  • 1.3837
  • 1.0549 *.0032 *
  • 2.4255 *
  • 1 7693
  • 1.3811..*. 1. 5830
  • 1 4106
  • 1.8497 15
  • 1.1171 *

.8622 *.9114 *

.7958

................... 2.1251

  • 2.4376
  • M-SUB-Q
  • 1.7333
  • 2.2438
  • AT 75% POWER, 405 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

...................................................................A H

O F

E D

C B

8

  • 1.1267
  • 1.5219
  • 1.2499
  • 1.5476
  • 1.2756
  • 1.3034
  • 1.0908
  • 1.1224 *
  • 1.5341
  • 1.2059
  • 1 4628
  • 1.1866.*.1 4319
  • 1.3973
  • 1.6548
  • 1.6262
  • 9
  • 1.5219
  • 1.2841
  • 1.5444
  • 1.3141
  • 1.5508
  • 1.2981
  • 1.4180 *

.8686

  • 1.4243
  • 1.1888
  • 1.3917
  • 1.1839
  • 1.4059
  • 1.2927
  • 2.0994 *
  • 1. 2059
  • 10
  • 1.2499
  • 1.5412
  • 1.2745
  • 1.5540
  • 1.3366
  • 1.5144
  • 1.2338 *.9146 *

.......... 1 1914

  • 1.4352
  • 1.1829
  • 1.3676
  • 1.2111.*. 1.4813
  • 1.9941
  • 1.4628
  • 11
  • 1.5476
  • 1.3120
  • 1.5487
  • 1.3240
  • 1.5455
  • 1.2841
  • 1.3869 *

.7968 *

  • 1.1866
  • 1.3946
  • 1.1869
  • 1.3813
  • 1 1888
  • 1.4243
  • 1.3211
  • 2.2934
  • 12
  • 1.2756
  • 1.5500
  • 1.3345
  • 1.5433 + 1.2970
  • 1.4630
  • 1.0501 *
  • 1.4319
  • 1.1842
  • 1.3689
  • 1.1898
  • 1.4113
  • 1.2555
  • 1.7335
  • 13
  • 1.3034
  • 1.2981
  • 1.5155
  • 1.2841
  • 1.4641
  • 1.0603 *.8032 *
  • 1.3973
  • 1.4056
  • 1.2109
  • 1.4243
  • 1.2550
  • 1.7290
  • 2.2008
  • 14
  • 1.0988
  • 1.4169
  • 1.2338
  • 1.3869
  • 1.0571 *

.8032 *

  • 1.6548
  • 1. 2927
  • 1.4818
  • 1.3209
  • 1.7335
  • 2.2819 *

.8675 *

.9146 *

.7968

  • 1.1224
  • 1.6262
  • 2.1019
  • 1.9941
  • 2.2916
  • M-SUB-Q

i 1

APPENDIX Page 55 of 140 McGuire 2 Cylce 10 Core Operating Limits Report lnable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 75% POWER, 405 EFPD, THIS IS LEVEL 2 OF 18 (LEVEL 18 = TCP OF CORE, LEVEL 1 = BOTTOM)

H F

B A

.............U..................E....**...D.........C.......*........**......

8

  • 1.0592
  • 1.4148
  • 1.1738
  • 1.4437
  • 1.2059
  • 1.2295
  • 1.0442
  • 1.0410 *

.......... 1. 2413

  • 1 4914
  • 1. 2171..*. 1.4511...*.1 4214
  • 1.6759
  • 1.6877 *
  • 1.6507
  • 9* 1.4148
  • 1.2038
  • 1.4384
  • 1.2434
  • 1.4400
  • 1.2188
  • 1.3216 *

.8225 *

............................... 102

  • 1.2137
  • 1.4363
  • 1.3301
  • 2.1357 *
  • 1.2413
  • 1.4558
  • 1.2216
  • 1.4.......................................

1.1974

  • 1.4491
  • 1.2531
  • 1.4137
  • 1.1588 *

.8547

  • 10
  • 1.1738
  • 1.4341
  • 1.4914
  • 1..,2247 1.4636
  • 1.2132
  • 1.3973
  • 1.2431
  • 1.5152
  • 2.0550
  • 11
  • 1.4437
  • 1.2402
  • 1.4448
  • 1.2413
  • 1.4405
  • 1.2038
  • 1.2841 *

.7443

  • 1.4575
  • 1.3700
  • 2.3616 *

.......... 1 4132

  • 1.2169
  • 1.4116
  • 1. 2204
  • 1.2171
  • 12
  • 1.2059
  • 1.4469
  • 1.2520
  • 1.4394
  • 1.2145
  • 1.3612 *.9875 *
  • ........... 2142 + 1.3986
  • 1.2217
  • 1.4440
  • 1.2953
  • 1.7840
  • 1.4511
  • 1.

.......+...................................**......

13

  • 1.2295
  • 1.2180
  • 1.4137
  • 1.2038
  • 1.3612 *

.9896 *

.7476 *

  • 1.4214
  • 1 4359
  • 1.2429
  • 1. 4575
  • 1.2947
  • 1.7788
  • 2.3570 *

...............+............................................

14

  • 1.0442
  • 1.3216
  • 1.1588
  • 1.2841 *

.9875 *

.7476

  • 152..*. 1.3694
  • 1 7840
  • 2 3570 *
  • 1.6759 *

....... *. 1.3301

  • 1.5 15
  • 1.0410 *

.8215 *

.8547 *

.7454

  • 1. 6877
  • 2.1382
  • 2. 0550
  • 2.3608
  • M-SUB-Q

......****........+............

AT 75% POWER, 405 EFFD, THIS IS LEVEL 1 OF 18 (LEVEL 18 TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.8075

  • 1.0410 *

.8729

  • 1.0689 *

.9125 *.9114 *

.7829 *.7219 *

  • 2.1129
  • 1.6426
  • 1.9571..*.1.6002
  • 1 8720..*.1.0718
  • 2.1834
  • 2. 3003
  • 9
  • 1.0410 *

.8857

  • 1.0635 *.9543
  • 1.0742 *

.8857 *.9585 *

.6180 *

  • 1.6426
  • 1.9285..*. 1 6080
  • 1.7915
  • 1.5917
  • 1.9291
  • 1.7890
  • 2. 7802
  • 10 *

.8729

  • 1.0592 *

.8900

  • 1.0806 *

.9275

  • 1.0453 *

.8322 *

.6126 *

.................*.......... 1. 5828

  • 1.8430
  • 1. 6383
  • 2.0604
  • 2.0080.*.*
  • 1.9571
  • 1.6136
  • 1.9204 11
  • 1.0609 *

.9521

  • 1.0785 *

.9146

  • 1.0646 *

.8857 *.9146 *.5419 *

  • 1.6002 + 1.7948
  • 1.5865
  • 1.8684
  • 1.6078
  • 1.9342
  • 1.8806
  • 3.1769
  • 12 *

.9125

  • 1.0742 *

.9264

  • 1.0635 *

.8964 *.9842

  • 7165 *
  • 1.8720
  • 1.5926
  • 1.8446
  • 1.6096
  • 1. 9105 + 1.7453
  • 2.4014
  • 13 *

.9114 *

.8857

  • 1.0453 *

.8857 *

.9853 *

.7326 *.5376 *

  • 1 8718
  • 1.9278
  • 1.6383
  • 1.9337
  • 1.7442
  • 2.3497
  • 3.2039
  • 14
  • 7829 *

.95P5 *

.8322 *.9146 *.7165 *.5376 *

............. 50

  • 2.0604
  • 1.8798
  • 2.4014
  • 3.2039 *
  • 2.1834
  • 1.78 15 *

.7219 *

.6100 *

.6126 *.5419

  • 2.3803
  • 2.7829
  • 2.8080
  • 3.1747
  • M-SUB-Q

)

APPENDIX Page 56 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 5 0 % POWER, 4 EFPD, THIS IS LEVEL 18 OF 18

{ LEVEL 1B = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.5880 *

.8622 *

.8011

  • 1.0057 *

.8900 *

.8943 *

.7722 *

.6212 *

  • 2.8299
  • 2.2002
  • 2.6637
  • 2.1205
  • 2.3922
  • 2.3767
  • 2.7513
  • 3.4018
  • 9*

.8622 *

.7593 *

.9553 *

.8857

  • 1.0025 *

.8461 *

.8793 *

.5623 *

  • 2.2802
  • 2.6549
  • 2.2313
  • 2.4037
  • 2.1239
  • 2.51 3.7586 *

.....................................***......**. 20

  • 2.4138
  • 10 *

.8011 *

.9543 *

.8107 *.9510 *

.8300 *

.9307 *

.7583 *

.5152 *

..................................... 2 5448

  • 2.2739
  • 2.7934
  • 4.0919 *
  • 2.6637
  • 2.2326
  • 2.6271
  • 2.2281 *

.9478 *

.7700 *

.8300 *

.7090 *

.7186 *

.4284

  • 11
  • 1.0057 *

.8857

  • 2.1205
  • 2.4066
  • 2.2368
  • 2.6322
  • 2.2348
  • 2.6642
  • 2.7260
  • 4.8174
  • 12 *

.8900

  • 1.0025 *

.8279 *

.8279 *

.5612 *

.6062 *

.5173 *

  • 2.3922
  • 2.1239
  • 2.5512
  • 2.2410
  • 2.6056
  • 2.4567
  • 3.3851
  • 13 *

.8943 *

.8450 *

.9296 *

.7079 *

.6051 *

.4113 *

.3213 *

  • 2.3767
  • 2.5136
  • 2.2764
  • 2.6661
  • 2.4553
  • 3.2827
  • 4.9022
  • 14
  • 7722 *

.8771 *

.7572 *

.7186 *

.5173 *

.3213 *

............. 182

  • 2.7973
  • 2.7280
  • 3.3879
  • 4.9022
  • 2.7513
  • 2.4

.4273

.6212 *.5612 *

.S141 *

........................ 1

  • 4.8232
  • M-SUB-Q 3.4018
  • 3.7656
  • 4.096 AT 50% PCWER, 4 EFPD, THIS IS LEVEL 17 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) i I

H G

F E

D C

B A

B*

.7775

  • 1.1513
  • 1.0828
  • 1.2831
  • 1.2220
  • 1.3163
  • 1.1171 *

.9778 *

)

  • 2.2154
  • 1.8139
  • 2.0158
  • 1.7419
  • 1.8270
  • 1.6914
  • 1.9892
  • 2.2655 *

.8215

  • 1.2723 + 1.2681 9
  • 1.1513
  • 1.0624
  • 1.2574
  • 1.1802
  • 1.3077

.... 139

  • 1.9575
  • 1.7769
  • 1.8905 + 1. 7062
  • 1.7502
  • 1.7554
  • 2.6970 *
  • 1.8..................................................................

10

  • 1.0828
  • 1.2531
  • 1.0913
  • 1.2370
  • 1.1867
  • 1.2670
  • 1.1245 *

.7765 *

  • 2.0158
  • 1.7831
  • 2.0430
  • 1.6020
  • 1.8632
  • 1 7570
  • 1. 9719
  • 2.8437
  • 11
  • 1.2831
  • 1.1792
  • 1.2327
  • 1.0571
  • 1.1310
  • 1.0410
  • 1.0924 *.6522
  • l
  • 1.7419
  • 1.8932.+.1.8076
  • 1.9653.*.1.7678
  • 1.9010
  • 1.8696.*. 3.3172
  • 12
  • 1.2220
  • 1.3098
  • 1.1856
  • 1.1299 *.7765 *

.9093 *.7915

  • 1.0657
  • 1.7701
  • 1.8759
  • 1.7781
  • 2.3373 *
  • 1.8270
  • 1.7041

.6244 *

.4884

  • 13
  • 1.3163
  • 7.2723
  • 1.2659
  • 1.0399 *

.9082

  • 1.6914
  • 1.7502
  • 1.7585
  • 1.9028
  • 1.7774
  • 2.3378
  • 3.4191
  • 14 ' 1.1171
  • 1.2659
  • 1.1224
  • 1.0913 *

.7904 *

.4873 *

  • 1.9892.*. 1.7577
  • 1.9748
  • 1.8713
  • 2.3386
  • 3.4218
  • 15 *

.9778 *

.8193 *

.7754 *.6512

  • 2.2655
  • 2.7042
  • 2.8477
  • 3.3226
  • M-SU8-Q l

i

APPENDIX Page 57 of 140 McGuire 2 Cylce 10 Core Operating Limits Report

.11able 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER, 4 EPPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 3 TOP OF CORE, LEVEL 1 = BOTTOM)

..........................................................B........A.....

H G

F E

D C

8*

.8557

  • 1.2063
  • 1.1695
  • 1.4319
  • 1.3377
  • 1.4994
  • 1.2691
  • 1.1588 *

.......... 1.7303

  • 1 9739
  • 1.6566
  • 1.7669
  • 1.5736
  • 1.8556
  • 2.0242 *
  • 2.1788
  • 9* 1.2863
  • 1.1642
  • 1.3944
  • 1.2841
  • 1.4930
  • 1.4459
  • 1.4791 *

.9393 *

............................ 1.0456

  • 1.5850
  • 1. 6331
  • 1.5948
  • 2.4995 '

1.7303

  • 1.8976
  • 1.7030
  • 10
  • 1.1695
  • 1.3891
  • 1.1792 ' 1.3837
  • 1.3355
  • 1.4523
  • 1.3023 *

.9050 *

....................................................... 1 8062 '.2.5901 *

  • 1.9739
  • 1.7093
  • 2.0005
  • 1.7114
  • 1.7523
  • 1.6200
  • 1.4319
  • 1.2831
  • 1.3794
  • 1.1588
  • 1.3077
  • 1.1963
  • 1.2981 *

.7658

  • 11 *
  • 1. 6566
  • 1.8473
  • 1.7178
  • 1.8908
  • 1.6349
  • 1.7661
  • 1.6621..*.3.0120
  • 12
  • 1.3377
  • 1.4951 ' 1.3345
  • 1.3055 *

.8857

  • 1.0839 '

.9371 *

  • 1.7669
  • 1.5826 '. 1.7553
  • 1.6369
  • 1 7470
  • 1.6148
  • 2.1144
  • 13
  • 1.4994
  • 1.4459
  • 1.4501
  • 1.1952
  • 1.0828 *

.7422 *

.5762 *

  • 1.5736
  • 1.6338 '. 1.6299
  • 1.7683
  • 1.6136
  • 2.1489
  • 3.1179
  • 14
  • 1.2691
  • 1.4769
  • 1.3002
  • 1.2970 *

.9361 *

.5751 *

  • 1.8556
  • 1.5972
  • 1.0093
  • 1.6635
  • 2.1155
  • 3.1203 *

.9371 *

.9039 *

.7636

  • 1.1588 *
  • 2.0242
  • 2.5070.*. 2 5950
  • 3.0166
  • M-SUB-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 15 0F 18 (LEVEL 18 : TOP OF CORE, LEVEL 1 e BOTTOM)

H G

F E

D C

B A

.8932 ' 1.3580

  • 1.2124
  • 1.5155
  • 1.3987
  • 1.5904
  • 1.3430
  • 1.2520
  • 8 *
  • 2.2942
  • 1.7853.*.2.0626
  • 1.6951..*. 1.8253
  • 1.6015
  • 1.0902
  • 2.0180
  • 9
  • 1.3580
  • 1.2134
  • 1.4705
  • 1.3420
  • 1.5915
  • 1.5326
  • 1.5979 *

.9992 *

  • 1.7853
  • 1.9824
  • 1.7509
  • 1.9151
  • 1.6052..*. 1.6636
  • 1.5924
  • 2.5350
  • 10 ' 1.2124
  • 1.4651
  • 1.2252
  • 1.4726
  • 1.4223
  • 1.5615
  • 1.4030 *

.9735 *

  • 2.0626
  • 1 7582
  • 2.0896
  • 1.7404
  • 1.7801
  • 1.6364
  • 1.8104
  • 2.5993
  • 11
  • 1.5155 + 1.3420
  • 1.4673 ' 1.2199
  • 1.4191
  • 1.2916
  • 1.4266 *

.8268 *

  • 1.6951
  • 1.9160
  • 1.7468
  • 1.9491
  • 1.6394
  • 1.7868
  • 1.6501
  • 3.0179
  • 12 ' 1.3987
  • 1.5936
  • 1.4212
  • 1.4159 *.9532
  • 1.1952
  • 1.0249 *
  • 1.8253
  • 1.6034
  • 1.7832
  • 1. 6387
  • 1. 7683
  • 1. 6135
  • 2.1203
  • 13
  • 1.5904
  • 1.5315
  • 1.5604
  • 1.2895
  • 1.1942 *

.8161 *

.6287 *

  • 1.6015
  • 1.6643
  • 1.6383
  • 1.7891
  • 1.6129
  • 2.1644
  • 3.1476 *

.............................................+.................

14

  • 1.3430 ' 1.5958
  • 1.4009
  • 1.4244
  • 1.0239 *

.6287 *

.................................... 2.1224

  • 3.1499 '.
  • 1.9128
  • 1.6508 *
  • 1.8902 '.1.5954 15
  • 1.2520 *

.9971 *

.9714 *

.8247

'.2.0100

  • 2.5411 '.2.6041
  • 3.0232
  • M-SUB 2

APPENDIX Page 58 of 140 McGuire 2 Cylce 10 Core Operating Limits Report ifable 1 (cont.)

isub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations i

l AT 50% POWER, 4 EFPD, THIS IS LEVEL 14 0F 14 (LEVEL 18 a TOP OF CORE, LEVEL 1 = BOTTOM)

.............................................................A G

F E

D C

B 8*

r/5

  • 1.3666
  • 1.2145
  • 1.5272
  • 1.4062
  • 1.6022
  • 1.3527
  • 1.2670 *

..................................................................... 1

  • 355
  • 1.9506
  • 2.2494
  • 1.8598
  • 2.0084
  • 1.7552
  • 2.0687
  • 2.195 9* 1.3666
  • 1.2188
  • 1.4791
  • 1.3473
  • 1.6086
  • 1.5444
  • 1.6226
  • 1.0078 *

................................. 0

  • 1.7552.*. 1.8233
  • 1.7310
  • 2.7698 *
  • 1.9506
  • 2.1809
  • 1.9015
  • 2.085 10
  • 1.2145
  • 1.4726
  • 1.2295
  • 1.4919
  • 1.4437
  • 1.5894
  • 1.4287 *

.9864 *

..................................................... 1.9490

  • 2.3322.*.

1.9092

  • 2.2708
  • 1.8718
  • 1.9102
  • 1.7552 *

'.2.2494

  • 1.5272
  • 1.3462
  • 1.4865
  • 1.2349
  • 1.4566
  • 1.3238
  • 1.4683 *.8450
  • 11 *
  • 1.8598
  • 2.0931
  • 1.8784
  • 2.1203
  • 1 7712..*. 1.9331
  • 1.7729
  • 3.2230
  • 12
  • 1.4062
  • 1.6108
  • 1.4416
  • 1.4533 *

.9800

  • 1.2381 1.0560 *

................................. 1.**1 9259

  • 1.7489
  • 2 2995 *
  • 2.0084
  • 1.7523
  • 1.9118
  • 1.774 1.6022
  • 1.5444
  • 1.5872
  • 1.3216
  • 1.2370 *

.8482 *.6512

  • 13 *
  • 1.7552
  • 1. 8241
  • 1.75.~.3
  • 1.9358
  • 1.7486
  • 2.3632
  • 3.4309
  • 14
  • 1.3527
  • 1.6194
  • 1.4255
  • 1.4662
  • 1.0549 *

.6512 *

  • 2.0607
  • 1.7338
  • 1.9517
  • 1.7743
  • 2.3015
  • 3.4

................................................. 416

  • 15
  • 1.2670
  • 1.0046 *

.9853 *

.8429

  • F-SUB.Q
  • 2.1951
  • 2. 7788
  • 2.8379
  • 3.2301
  • M-SUB-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 13 0F 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.9339

  • 1.4290
  • 1.2574
  • 1.5883
  • 1.4491
  • 1.6633
  • 1.3966
  • 1.3205 *
  • 2.7652
  • 2.0942
  • 2.4434
  • 2.0168
  • 2.1919
  • 1.9003
  • 2.2463
  • 2.3547
  • 9
  • 1.4298
  • 1 2659
  • 1.5422
  • 1.3998
  • 1.6740
  • 1.6022
  • 1.6954
  • 1.0410 *
  • 2.0942
  • 2.3488
  • 2 0521...*.2.2533
  • 1.6832
  • 1.9791
  • 1. 0604
  • 2.9987
  • 10
  • 1.2574
  • 1.5347
  • 1.2723 + 1.5604
  • 1.5090
  • 1.6675
  • 1.4951
  • 1.0271 *
  • 2.4434
  • 2.06............................... 1. 0759
  • 2.0925
  • 3.0535 *
  • 2.4604
  • 2.0087
  • 2.0522 *

.............. 17 11

  • 1.5883
  • 1.3944
  • 1.5540
  • 1.2938
  • 1.5465
  • 1.4019
  • 1.5647 *

.8846

  • 2.0168
  • 2.2626
  • 2.0189
  • 2.2744
  • 1.8775
  • 2.0629
  • 1.8726
  • 3.4571
  • 12
  • 1.4491
  • 1.6761
  • 1.5069
  • 1.5433
  • 1.0442
  • 1.3355
  • 1.1278
  • 2.1919
  • 1.8849
  • 2.0552
  • 1.8815
  • 2.0884
  • 1.8782
  • 2.4628
  • 13
  • 1.6633
  • 1.6011
  • 1.6654
  • 1.3938
  • 1.3345 *

.9178 *.6994 *

  • 1.9003
  • 1.9791
  • 1.8792
  • 2.0658
  • 1 8774
  • 2.5699
  • 3.7314
  • 14
  • 1.3966
  • 1.6933
  • 1.4930
  • 1.5626
  • 1.1267 *

.6994 *

  • 2.2463
  • 1.8636
  • 2.0956
  • 1.8742
  • 2.4655
  • 3.7346
  • 15
  • 1.3205
  • 1.0378
  • 1.0260 *

.8825

  • 2.3547
  • 3.0070
  • 3.0578
  • 3.4654
  • M-SUB.Q

i t

APPENDIX Page 59 of 140 McGuire 2 Cylce 10 Core Operating Limits Report l'able 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 504 F0WER, 4 EFPD, THIS IS LEVEL 12 0F 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM)

......................F.........E....................................A.....

H G

D C

B 8*

.9971

  • 1.4737
  • 1.2841
  • 1.6086
  • 1.4619
  • 1.6793
  • 1.4062
  • 1.3302 *
  • 3.1423
  • 2.3603
  • 2.7734
  • 2. 2327
  • 2 4312.*. 2.1019
  • 2.4822.*. 2.5894..*.

9* 1.4737

  • 1.3002
  • 1.5679
  • 1.4234
  • 1.7040
  • 1.6161
  • 1.7179
  • 1.0464 *
  • 2.3683
  • 2.6624
  • 2.3196
  • 2.5499
  • 2. 0949
  • 2.1914
  • 2 0488
  • 3.3103
  • 10
  • 1.2841 ' 1.5604
  • 1.2927
  • 1.5926
  • 1.5401
  • 1.7018
  • 1.5219
  • 1.0389 *
  • 2.7982
  • 2.2566
  • 2.3125
  • 2.
  • 2.3414
  • 3.3611 *

................................... 1034

  • 2.7734
  • 2 3307 11
  • 1.6086
  • 1.4100
  • 1.5862
  • 1.3334
  • 1.6119
  • 1.4587
  • 1.6236 *

.9029 *

  • 3.8950 *

....................................................... 2. 0944 2.2327

  • 2.5577
  • 2.2683
  • 2.5603
  • 2.1044
  • 2.3175
  • 12
  • 1.4619 + 1.7010
  • 1.5390
  • 1.6086
  • 1.1503
  • 1.4341
  • 1.1845 *
  • 2.4312.*. 2.0929
  • 2.3174
  • 2.1085..*. 2 3372
  • 2. 0954....... 502.*
  • 2.7 13
  • 1.6793
  • 1.6161
  • 1.6997
  • 1.4566
  • 1.4330
  • 1.0046 *

.7454 *

  • 2.1019
  • 2 1925
  • 2.1074
  • 2.3200
  • 2.0943
  • 2.8698
  • 4.1681.*

1.5187

  • 1.6215
  • 1.1835 *

.7454

  • 14
  • 1.4062
  • 1.7157
  • 2.4822.*.2 0526
  • 2. 3452
  • 2.0964
  • 2.7616
  • 4.1721
  • 15
  • 1.3302
  • 1.0432
  • 1.0378 *

.9010

  • 2.5894
  • 3.3178
  • 3.3663
  • 3.9020
  • M-SUB-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 11 0F 18 (LEVEL 10 2 TOP OF CORE, LEVEL 1 = BOTTOM)

.......................**..........................................A H

G F

E D

C B

8

  • 1.0924 ' 1.5165
  • 1.3066
  • 1.6140
  • 1.4608
  • 1.6793 ' 1.4019
  • 1.3248 *
      • ...... 2. 7283
  • 3.1943
  • 2.4808
  • 2.7047
  • 2.3377
  • 2.7645
  • 2.8753..*.
  • 3.6468
  • 9
  • 1.5165
  • 1.3366
  • 1.5808
  • 1.4351
  • 1.7200
  • 1.6183
  • 1.7211
  • 1.0410 '
  • 2.7283
  • 3.0775
  • 2.6018
  • 2.8435
  • 2.3265
  • 2.4407
  • 2.2745
  • 3.6836
  • 10
  • 1.3066
  • 1.5733
  • 1.3045
  • 1.6100
  • 1.5594
  • 1.7200 ' 1.5326
  • 1.0399 *
  • 3.1943 + 2 6142
  • 3.1757
  • 2.5428
  • 2.6299
  • 2.3503 + 2.5956
  • 3.7244
  • 11
  • 1.6140
  • 1.4298 ' 1.6033
  • 1.3773
  • 1.6729
  • 1.5112
  • 1.6697 *

.9125

  • 2.5517
  • 2.9657
  • 2.4339
  • 2.6862
  • 2.4208
  • 4.3587
  • 2.4000
  • 2.8491
  • 12
  • 1.4608
  • 1.7190
  • 1.5583
  • 1.6697
  • 1.3869
  • 1.5707
  • 1.2391
  • 2.3240
  • 2.6331 2.4381
  • 2.7060
  • 2.4193
  • 3.1952 *
  • 2.7047
  • 1.7179
  • 1.5090
  • 1.5787
  • 1.1267
  • 7936
  • 13 ' 1.6793
  • 1.6161
  • 2.3377
  • 2.4421
  • 2.3528
  • 2.6895
  • 2.4180
  • 3.3211
  • 4.8225
  • l 1

14 ' 1.4019

  • 1.7179
  • 1.5305
  • 1.6675 ' 1.2370 *.7936 *
  • 2.7645
  • 2.2781
  • 2.6002 2.4234
  • 3.1997
  • 4.8274
  • 15
  • 1.3248
  • 1.0378
  • 1.0378 *

.9104

'.2.8753

  • 3.6930
  • 3.7276
  • 4.3674
  • M-SUB-Q

)

APPENDlX Page (K) of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER, 4 EFPD, THIS IS LEVEL 10 OF 10 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D B

A

.................................................C...............**.......

8

  • 1.1674
  • 1.5776
  • 1.3441
  • 1.6493
  • 1.4823
  • 1.7093
  • 1.4180
  • 1.3473 *
  • 3.8899
  • 2.9020
  • 3.4135
  • 2.6997
  • 2.9649
  • 2.5502
  • 3.0201
  • 3.10

........................................................c*..........

59

  • 9
  • 1.5776
  • 1.3912
  • 1.6236
  • 1.4705
  • 1.7671
  • 1.6504
  • 1.7586
  • 1.0528 *
  • 2,9020
  • 3.2805
  • 2.8252
  • 3.1081
  • 2.5340
  • 2.6700
  • 2. 4710
  • 4.0075..*

10

  • 1.3441
  • 1.6151
  • 1.3345
  • 1.6558
  • 1.6022
  • 1.7602
  • 1.5701
  • 1.0592 *
  • 3.4135
  • 2.8398
  • 3.4458
  • 2.7680
  • 2. 8602
  • 2.5592
  • 2.8306
  • 4.0520
  • 11
  • 1.6493
  • 1.4641
  • 1.6483
  • 1.4362
  • 1.7522
  • 1.5707
  • 1.7447

.9350 *

................... 2. 7803

  • 3.1643
  • 2.5941
  • 2.8772
  • 2.6080
  • 4.7567
  • 2.6997
  • 3.1125
  • 12
  • 1.4823
  • 1.7630
  • 1.6001
  • 1.7489
  • 1.5358
  • 1.7243
  • 1.3045 *

..... 49

  • 2 5310
  • 2. 8659
  • 2.S987
  • 2 9136
  • 2. 6002
  • 3.4649 *
  • 2.96 13
  • 1.7093
  • 1.6483
  • 1.7661
  • 1.5765
  • 1.7243
  • 1.2338 *

.8450 *

  • 2. 5502
  • 2.6717
  • 2.5622
  • 2.8810
  • 2.5987
  • 3.6167
  • 5.3109
  • 14
  • 1.4180
  • 1.7554
  • 1.5669
  • 1.7425
  • 1.3034 *

.8439 *

.............. 52

  • 2.8361
  • 2. 6111
  • 3.4676
  • 5.3173 *
  • 3.0201
  • 2.47......................................

15

  • 1.3473
  • 1.0496
  • 1.0571 *

.9328

  • 3.1059.*.4.0185
  • 4.0558
  • 4.7671...* M-SUS-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 9 OF 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

l 8

  • 1.1599
  • 1.5594
  • 1.3270
  • 1.6204
  • 1.4544
  • 1.6740
  • 1.3880
  • 1.3141
  • l

........... 1.**.3.1303 *

  • 3.9783
  • 2.9669
  • 3.4485
  • 2.6378
  • 2.8962
  • 2 5021
  • 2.985 I

9

  • 1.5594
  • 1.3794
  • 1.5979
  • 1.4469
  • 1.7404
  • 1.6204
  • 1.7232
  • 1.0282 *
  • 2.9669
  • 2.3500
  • 2.7558
  • 3.0285
  • 2.4850
  • 2.6267
  • 2.4544
  • 4.0148
  • j 10
  • 1.3270
  • 1.5894
  • 1.3152
  • 1.6322
  • 1.5787
  • 1.7447
  • 1.5444
  • 1.036,'
  • l
  • 3.4485
  • 2.7697
  • 3.3767
  • 2.7097
  • 2.8306
  • 2.5223
  • 2.8252
  • 4.0937 I

j 11

  • 1.6204
  • 1.4405
  • 1.6247
  • 1.4298
  • 1.7425
  • 1.5690
  • 1.7318 *.9211 *
  • 2.6378
  • 3.0327
  • 2.7215
  • 3.2273
  • 2.6458
  • 2.9390
  • 2.6651
  • 4.8463
  • 12
  • 1.4544
  • 1.7382
  • 1.5776
  • 1.7393
  • 1.5444
  • 1.7339
  • 1.3013 *
  • 2.8962
  • 2.4822
  • 2.8343
  • 2.6522
  • 2.9750
  • 2.6538
  • 3.5435
  • 13
  • 1.6740
  • 1.6103
  • 1.7414
  • 1.5669
  • 1.7339
  • 1.2445 *

.8472 *

. 2. 5021

  • 2.6283
  • 2.5252
  • 2.9429
  • 2.6522
  • 3.6961
  • 5.4362
  • 14
  • 1.3000
  • 1.7200
  • 1.5422
  • 1.7297
  • 1.2991 *

.8461 *

  • 2.9851
  • 2.4585
  • 2.8306
  • 2.6684
  • 3.5492
  • 5.4430
  • 15
  • 1.3141
  • 1.0249
  • 1.0357 *.9200
  • 3.1303
  • 4.0296
  • 4.0975
  • 4.8570
  • M-SU8-Q 4

I J

Y i

APPENDIX Page 61 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations i

l AT 50% POWER, 4 EFFD, THIS IS LEVEL 8 OF 10 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

....................***.....****..........................B.........A.....

H G

F E

D C

8

  • 1.1663
  • 1.5808
  • 1.3366
  • 1.6376
  • 1.4598
  • 1.6879
  • 1.3912
  • 1.3270 *
  • 3.8796
  • 2.8380
  • 3.2609
  • 2.4907
  • 2.7558
  • 2.3668
  • 2.8398
  • 2.9429
  • 9* 1.5808
  • 1.3923
  • 1.6183
  • 1.4608
  • 1.7639
  • 1.6322
  • 1.7425
  • 1.0292 *
  • 2.8380
  • 3.2273
  • 2.5941
  • 2.8715.*. 2.3490
  • 2.4921
  • 2 3154
  • 3.8054
  • 10
  • 1.3366
  • 1.6097
  • 1.3238
  • 1.6568
  • 1.5969
  • 1.7757
  • 1.5604
  • 1.0442 *
  • 3.2609
  • 2.6080
  • 3.1990
  • 2.5547
  • 2 6798
  • 2 3784
  • 2.6733
  • 3.8761.*.

11

  • 1.6376
  • 1.4533
  • 1.6463
  • 1.4459
  • 1.7746
  • 1.5904
  • 1.7671 *.9286 *
  • 2.4907
  • 2.8772
  • 2.5667
  • 3.1483
  • 2.5712
  • 2.8677
  • 2.5788
  • 4.6065
  • 12
  • 1.4598
  • 1.7607
  • 1.5926
  • 1.7704
  • 1.5733
  • 1.7736
  • 1.3227 *
  • 2.7558
  • 2.3465
  • 2.6848
  • 2.5757
  • 2.9370
  • 2.6000
  • 3.4676
  • 13
  • 1.6879
  • 1.6301
  • 1.7725
  • 1.5883
  • 1.7736
  • 1.2670 *

.8600 *

  • 2.3669
  • 2.4935
  • 2.3822
  • 2.8715
  • 2.6064
  • 3.6621
  • 5.3433
  • 14
  • 1.3912
  • 1.7404
  • 1.5572
  • 1.7650
  • 1.3216 *

.8589 *

............................ 2. 5818

  • 3.4731.*.5.3498 *
  • 2.8398
  • 2.3203
  • 2.6798
  • 15
  • 1.3270
  • 1.0271
  • 1.0421 *

.9275

  • 2.9429
  • 3.8153
  • 3.8830
  • 4.6162
  • M-SUB-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 7 OF 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 = BOTTOM)

........................................D...c.....C.......B.........A H

O F

E 8*

1.1449

  • 1.5594
  • 1.3141
  • 1.6129
  • 1.4341
  • 1.6579
  • 1.3623
  • 1.3013 *
  • 3 6287
  • 2.6126
  • 2.9974
  • 2.2960
  • 2.5487
  • 2.1892
  • 2.6236
  • 2. 7131
  • 9
  • 1.5594
  • 1.3709
  • 1.5947
  • 1.4362
  • 1.7372
  • 1.6022
  • 1.7147
  • 1.0067 *
  • 2.6126
  • 2.9831
  • 2.3874
  • 2.6506
  • 2.1696
  • 2.3081
  • 2.1389
  • 3.5178
  • I 10
  • 1.3141
  • 1.5862
  • 1.3023
  • 1.6354
  • 1.5712
  • 1.7532
  • 1.5337
  • 1.0228 *
  • 2.9974
  • 2.4005
  • 2.9469
  • 2.3578
  • 2.4850
  • 2.2002
  • 2.4752 + 3.5753
  • 11
  • 1.6129
  • 1.4298
  • 1.6258
  • 1.4244
  • 1.7522
  • 1.5669
  • 1.7447 *

.9114 *

  • 2.2960
  • 2.6571
  • 2.3693
  • 2.9370
  • 2.3966
  • 2.6798
  • 2.3953
  • 4.2487
  • 12
  • 1.4341
  • 1.7350
  • 1.5679
  • 1.7479
  • 1.5530
  • 1.7543
  • 1.3023 *
  • 2.5487
  • 2.1675
  • 2.4879
  • 2.4018
  • 2.7768
  • 2.4434
  • 3.2464
  • 13
  • 1.6579
  • 1.6001
  • 1.7500
  • 1.5647
  • 1.7543
  • 1.2488 *

.8461 *

  • 2.1892
  • 2.3093
  • 2.2035
  • 2.6831
  • 2.4434
  • 3.4404
  • 5.0071
  • 14
  • 1.3623
  • 1.7115
  • 1.5305
  • 1.7425
  • 1.3013 *

.8450 *

  • 2.6236
  • 2.1431
  • 2.4808
  • 2.3979
  • 3.2512
  • 5.0128
  • 15
  • 1.3013
  • 1.0046
  • 1.0217 *

.9093

  • 2.7131.*. 3.5292.*. 3.5812
  • 4.2570.* M-SUB-Q

l APPENDIX Page 62 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report lnable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER.

4 EFPD.

THIS IS LEVEL 6 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BO': TOM)

......................F.........E........D.........C.........B.........A.....

H O

8

  • 1.1063
  • 1.5069
  • 1.2702
  • 1.5551
  • 1.3827
  • 1.5947
  • 1.3088
  • 1.2466
  • 258..*. 2. 7927
  • 2.1557
  • 2.3979
  • 2.0623
  • 2.4794
  • 2.5772..*
  • 3.3431
  • 2.4 9
  • 1.5069
  • 1.3248
  • 1.5401
  • 1.3837
  • 1.6729
  • 1.5401
  • 1.6472 *

.9650 *

  • 2.4259
  • 2 7750
  • 2.2327
  • 2.4836 '.2.0421..*. 2.1772
  • 2. 0195
  • 3.3406..*.

10

  • 1.2702
  • 1.5315
  • 1.2563
  • 1.5776
  • 1.5123
  • 1.6890
  • 1.4726 *

.9900 *

............ 2453

  • 2.7540
  • 2.2000
  • 2.3302.*.2.0642
  • 2.3302
  • 3.3871 *
  • 2.7927 *2 11 ' 1.5551
  • 1.3773
  • 1.5679
  • 1.3741
  • 1.6879
  • 1.5000
  • 1.6761 *

.8739 *

..................... 2100

  • 2.7283................

259

  • 2.4950
  • 2.2282
  • 2.2
  • 4.0038 *
  • 2.1557
  • 2.4893
  • 2.

12

  • 1.3827
  • 1.6708
  • 1.5090
  • 1.6847
  • 1.4951
  • 1.6890
  • 1.2499 *
  • 3.0348 *

......................................... 12

  • 2.2733
  • 2.3979
  • 2.0402
  • 2.3340
  • 2.2316
  • 2.57 13
  • 1.5947
  • 1.5380
  • 1.6858
  • 1.5058
  • 1.6900
  • 1.2006 *

.8107 *

  • 2.0623
  • 2.1783
  • 2.0672
  • 2 4992
  • 2.2722.*.3.2178
  • 4.7005
  • 14
  • 1.3088
  • 1.6440
  • 1.4705
  • 1.6750
  • 1.2488 *

.8107 *

............................ 2.2316

  • 3.0390
  • 4.7056 *
  • 2.4794
  • 2.0232
  • 2.3352
  • 15
  • 1.2466 *

.9618 *

.9778 *

.9718

  • 2 5772
  • 3.3403
  • 3.3924
  • 4.0112..* M-SUB-Q AT 50% POWER.

4 EFTD, THIS IS LEVEL 5 0F 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 DOTTOM)

C F

E D

C B

A

....H.....................................................................

8

  • 1.0013
  • 1.4994
  • 1.2563
  • 1.5412
  • 1.3623
  • 1.5744
  • 1.2811
  • 1.2274 *
  • 3.0015
  • 2.1740
  • 2.5472
  • 1.9802.*. 2.2225
  • 1.9052
  • 2. 3105
  • 2.3966
  • 9
  • 1.4994
  • 1.3120
  • 1.5294
  • 1.3666
  • 1.6536
  • 1.5155
  • 1.6247 *

.9446 *

... 1740 '. 2.4850

  • 2.0303
  • 2.2064 '.1 8838
  • 2.0167
  • 1.8670
  • 3 1236
  • 2.

10

  • 1.2563
  • 1.5200
  • 1.2413
  • 1.5604
  • 1.4876
  • 1.6606
  • 1.4400 *.9618 *
  • 2.02
  • 1.8961
  • 2.1536
  • 3.1483 *
  • 2.5472..'. 2.0488
  • 2.5237.....................

13

  • 2.1431 11
  • 1.5412
  • 1.3602
  • 1.5508
  • 1.3527
  • 1.6675
  • 1.4833
  • 1.6547 *

.8547 *

....................................................... 2.0139

  • 3.7118 *
  • 1.9802
  • 2.2924
  • 2.0307
  • 2.4530
  • 1.9982
  • 2.2476
  • 12
  • 1.3623
  • 1.6515
  • 1.4844
  • 1.6633
  • 1.4705
  • 1.6675
  • 1.2274 *
  • 2.2225
  • 1.0822
  • 2.1462
  • 2.0028 2 3302
  • 2.0545
  • 2.7471
  • 13
  • 1.5744
  • 1.5133
  • 1.6643 ' 1.4812 ' 1.6675 1.1760 *.7936 *

. 1. 9052

  • 2.0176
  • 1.8986
  • 2.2500
  • 2.0545
  • 2.9390
  • 4.2946
  • 14
  • 1.2841
  • 1.6276
  • 1.4459
  • 1.6526
  • 1.2263 *

.7925 *

  • 2.3105
  • 1.0702
  • 2.1579
  • 2.0167
  • 2.7506
  • 4.2988
  • 15
  • 1.2274 *

.9425 *

.9596 '

.8525

  • 2.3966
  • 3.1325
  • 3.1.F51
  • 3.7181..............' M - S U B - Q I

i

APPENDIX Page 63 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1 fable 1 (cont)

F-sub-Q/M sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER, 4 EFPD, THIS IS LEVEL 4 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 e BOTTOM)

....H........G.......****........................**........B.........A F

E D

C 1.4908

  • 1.2124
  • 1.1492
  • 8* 1.0453
  • 1.4309
  • 1.2027
  • 1.4662
  • 1.2981 *

.............. 16

  • 2.4058
  • 1. 9143
  • 2.1473..*. 1.8559
  • 2.2639
  • 2.3745 *
  • 2.8454
  • 2.05 9
  • 1.4309
  • 1.2563
  • 1.4587
  • 1.2991
  • 1.5615
  • 1.4298
  • 1.5272 *

.8868 *

  • 2.0516
  • 2.3490
  • 1.9545
  • 2.1980
  • 1.8333
  • 1 9659
  • 1 8318
  • 3.0818.*

10

  • 1.2027
  • 1.4512
  • 1.1867
  • 1.4791
  • 1.4052
  • 1.5712
  • 1.3612 *

.9007 *

.................. 1.e380

  • 2 1009
  • 3 1015..*
  • 2.0681 *

.................. 111.*.1.9450

  • 2 4058
  • 1.9650
  • 2.4 11
  • 1.4662
  • 1.2927
  • 1.4716
  • 1.2841
  • 1.5701
  • 1.3955
  • 1.5476 *

.0000 *

................... 1.9545

  • 2.3440
  • 1. 9253
  • 2 1696
  • 1 9467
  • 3.6257 *
  • 1.9143
  • 2.2035
  • 12
  • 1.2981
  • 1.5594
  • 1.4019
  • 1.5669
  • 1.3848
  • 1.5647
  • 1.1481 *
  • 2.1473
  • 1. 8326
  • 2.0711..*. 1 9304...... 2147
  • 1.9650
  • 2.6635 *
  • 2, 13
  • 1.4908
  • 1.4276
  • 1.5679
  • 1.3934
  • 1.5650
  • 1.1021 *

.7411 *

  • 1 655 9
  • 1. 9 6 6 8
  • 1. 8 410
  • 2.172 9
  • 1. 9 64 2 + 2. 8 016
  • 4.14 02
  • 14
  • 1.2124
  • 1.5251
  • 1.3591
  • 1.5455
  • 1.1460 *

.7411 *

  • 2.2639
  • 1.8349
  • 2.1049
  • 1.9484
  • 3.66f;
  • 4.1402 *

...................................+.................

15

  • 1.1492 *

.8846 *

.8996 *

.7979

.........................** 3.6347

  • 2.3745
  • 3.0905
  • 3.1059 *
  • M-SUB-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 3 0F 18 (LEVEL 18 e TOP OF CORE, LEVEL 1 s BOTTOM)

..........................................................B.......A H

G F

E D

C 8

  • 1.0153
  • 1.3891
  • 1.1717
  • 1.4191
  • 1.2563
  • 1.4276
  • 1.1481
  • 1.0764 *
  • 2.6538
  • 1.9346
  • 2.2710
  • 1 8473
  • 2.0740
  • 1.0151
  • 2.2442
  • 2.3848
  • 9
  • 1.3891
  • 1.2209
  • 1.4191
  • 1.2595
  • 1.4898
  • 1.3623
  • 1.4426 *

.8354 *

  • 1.9346
  • 2. 2013
  • 1.8646
  • 2.1060
  • 1.7869
  • 1. 9278
  • 1.8143
  • 3.0796
  • 10
  • 1.1717
  • 1.4105
  • 1.1567
  • 1.4266
  • 1.3409
  • 1.4908
  • 1.2852 *

.8461 *

.......................................... 1.7891

  • 2.0681
  • 3.0905 *
  • 2 2710
  • 1.0750
  • 2.2924
  • 1.0678
  • 1.999^
  • 11
  • 1.4191
  • 1.2541
  • 1.4201
  • 1.2370
  • 1.4908
  • 1.3227
  • 1.4480 *

.7465 *

  • 1.8473
  • 2.1110
  • 1.8766
  • 2 2135
  • 1. 8473
  • 2.0849
  • 1 9043
  • 3.6047
  • 1.3398
  • 1.4876
  • 1.3141
  • 1.4758
  • 1.0742
  • 12
  • 1.2563
  • 1.4087
  • 2.0740
  • 1.7891
  • 2.0019
  • 1.8512
  • 2.1462
  • 1.9177
  • 2.6033
  • 13
  • 1.4276
  • 1.3602
  • 1.4876
  • 1.3205
  • 1.4758
  • 1.0335 *

.6919 *

  • 1.8151
  • 1.9207
  • 1.7920
  • 2.0879
  • 1.9168
  • 2.7680
  • 4.0937
  • 14
  • 1.1481
  • 1.4405
  • 1.2831
  • 1.4469
  • 1.0731 *

.6908 *

  • 2.2442
  • 1.8173
  • 2.0730
  • 1.9068
  • 2.6064
  • 4.0975 *

.8332 *

.8439 *

.7443

  • 1.0764
  • 2.3840
  • 3.0003
  • 3.0949 + 3.6107
  • M-SUB-Q

i APPENDIX Page 64 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER, 4 EFPD, THIS IS LEVEL 2 0F 18 (LEVEL 18 3 TOP OF CORE, LEVEL 1 = BOTPCM)

....H.............................................C........B.........A G

F E

D 8*

.9350

  • 1.2595
  • 1.0764
  • 1.2927
  • 1.1503
  • 1.2552
  • 1.0014 *

.9029 *

..... 2. 0010

  • 2.3277
  • 1.9312 '. 2.1568
  • 1 9704
  • 2.4599 '.2. 7215..*.
  • 2.7097 9
  • 1.2595
  • 1.1106
  • 1.2970
  • 1.1631
  • 1.3227
  • 1.2038
  • 1.2456 *

.7240 *

  • 2.0809
  • 2.00 3.3976 *
  • 2.0010 2.2722
  • 1.9321
  • 2.1632
  • 1.8977

.........'.................................................. 19

  • 10
  • 1.0764
  • 1.2906
  • 1.0699
  • 1.2895
  • 1.1984
  • 1.3130
  • 1.1149 *

.7229

  • 2.3440
  • 1.9563
  • 2.1100
  • 1.9236
  • 2.2628
  • 3.4485 *
  • 2.3277
  • 1.9424
  • 11
  • 1.2927
  • 1.1578
  • 1.2831 ' 1.1267
  • 1.3173
  • 1.1642
  • 1.2188 *

.6330

  • 1.9312 2.1686
  • 1.9650
  • 2.2816
  • 1.9784
  • 2.2305
  • 2.1326
  • 4.0259
  • 12
  • 1.1503
  • 1.3205
  • 1.1963
  • 1.3141
  • 1.1620
  • 1.2702 *

.9168 *

................... 2.1131

  • 1 9838
  • 2.2546
  • 2.0701.*.2.8584 *
  • 2.1568
  • 1.9010
  • 1.3109
  • 1.1620
  • 1.2713 *

.8943 *

.5912

  • 13
  • 1.2552
  • 1.2027

.........'......... 1 9261

  • 2.2350
  • 2.0691 '.2.9609
  • 4.4655 *
  • 1.9704 2.0829
  • 14
  • 1.0014
  • 1.2434 ' 1.1128 ' 1.2177 *

.9157 *.5912 *

  • 2.4599
  • 2.0056
  • 2.2674
  • 2.1347 2.8621
  • 4.4655
  • 15 *

.9029 *

.7229 *.7219 *

.6319

  • 2.7215..*. 3.4056
  • 3.4540
  • 4.0296
  • M-SUB-Q AT 50 % PCWER.

4 EFPD, THIS IS LEVEL 1 CF 18 (LEVEL 18 = TCP OF CORE. LEVEL 1 s DOTTOMI H

G F

E D

C B

A 8*

.6726 *

.8879 *

.7272 *

.9361 *

.7904 *

.0022 *

.6587 *

.5344 *

.......... 2. 7283

  • 3.3178 '.2.5727......'........'.. 9851.*. 3.6377
  • 4.4564.*e 3.0432 2.
  • 3.6077 9*

.8879 *

.7368 *.9136 *

.8193 *.9436 *

,7668 *

.8043 *.4702 *

  • 2.7283 '.3.2005
  • 2.6458
  • 2.9509
  • 2.5682
  • 3.1529
  • 3.0035
  • 5.0768
  • 10 *

.7272 *

.9104 *

.7443 *.9318 *

.7968 *.9136 *.6983 *.4520 '

3.3170

  • 2.6522
  • 3.2609
  • 2.6158
  • 3.0501
  • 2.6749
  • 3.4814
  • 5.3433 *

.8161 *

.9264 *

.7503 *.9211 *

.7509 *

.7476 *

.2963

  • 11 *

.9361

... 5727

  • 2.9589
  • 2.6315
  • 3.2368
  • 2.6997
  • 3.3178
  • 3. 3254
  • 6.1985 *
  • 2....................................................................

12 *

.7904 *

.9414 *

.7936 *.9168 *.7561 *.8172 *.5700 *

  • 3.0432..*.2. 5727 '.3.0688
  • 2.7097
  • 3.3254
  • 3.0949
  • 4.4159 *

.3738

  • 13 *

.0022 *

.7668 *.9125 *

.7497 *

.8172 *

.5794

  • 2.9851
  • 3.1551
  • 2.6798
  • 3.3228
  • 3.0949
  • 4.3805
  • 6.763R
  • .8032 '.6972 *

.7465 *

.5'98 *

.3738 '

14 *

.6587

  • 6.7638 *
  • 3.6377
  • 3.0077
  • 3.4870
  • 3.3304..'.4.4204 15 *

.5344 *

.4702 *

.4509 *

.3952

..................'............ 2073

  • M-SUB-Q 5.0827 5.3498
  • 6.

4.4564

  • APPENDIX Page 65 of 140 McGuire 2 Cylce 10 Core Operating Limits Report lilble 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin)- Normal Operations j

l AT 50% POWER, 200 EFPD, THIS IS LEVEL 18 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

.s.......................................................................

8*

.6297 *

.9286 *

.8547

  • 1.0774 *

.9564 *

.8996 *

.6704 *

.5216 *

................... 2. 3126 *...... 1. 0826

  • 2. 1329
  • 2.1882..*. 2.5614
  • 3.0265
  • 2.6019 ' 2.1203
  • 9*

.9286 *

.7979 *

.9896 *

.9510

  • 1.0689 *

.8868 *

.8739

.5301 *

..... 8999

  • 2.2876
  • 2.2162.*.3.4270 *
  • 2 1203
  • 2.3901.*.1. 9361.*.2. 1133
  • 1.

10 *

.8547 *

.9907 *

.7401 *

.9971 *

.8986

  • 1.0035 *

.7829 *

.5387 *

..................... 2005

  • 1.9455
  • 2.2430
  • 2 0469
  • 2.5729.*. 3.6315 *
  • 2.3126
  • 1.9392
  • 2.

11

  • 1.0774 *

.9510 *

.9950 *

.7968 *.9211 *

.7915 *

.8086 *

.4819

  • 2.1202
  • 2.5326
  • 2.4492
  • 4.1426 *

... 88261.....*.2.1148* 1. 9516

  • 2. 3684
  • 12 *

.9564

  • 1.0699 *

.8986 *

.9200 '.6297 *

.7026 *

.5912 *

  • 2.1329
  • 1.9003
  • 2. 2468
  • 2.1243
  • 2.4220
  • 2. 3181
  • 3.2556
  • 13 *

.8996 *

.8857

  • 1.0035 *

.7915 *

.7026 *

.4830 *

.3909 *

' 3.0972 ' 4.5019

  • 2.1882
  • 2.2889
  • 2.0404
  • 2.5326
  • 2.3181 e.........................................*.....................

.7829 *

.0086 *

.5901 *

.3909 *

.8729 14 *

.6704

  • 4.5040 *
  • 2.5614
  • 2.2191
  • 2.5746
  • 2.4492..*.3 2556
  • 15 *

.5216 *

.5301 *

.5387 *

.4819

  • 3.4310
  • 3.6360
  • 4.1426
  • M-SUB-Q AT 50% POWER, 200 EFPD, 1HIS IS LEVEL 17 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 a BOTTCM)

H G

F E

D C

B A

8*

.8140

  • 1.2563
  • 1.1663
  • 1.4105
  • 1.2959
  • 1.2009 *

.9757 *

.8450 *

....................................................... 1 9492

  • 2.1502
  • 2.0834
  • 1.6798
  • 1.8126
  • 1.5201
  • 1.6723
  • 1.6517
  • 1.2766
  • 1.2584 *

.7465

  • 9* 1.2563
  • 1.1213
  • 1.3313
  • 1.2691
  • 1.4041

...........................'........................ 2..*.1.6749

  • 2 6100 *
  • 1.6798
  • 1.0428
  • 1.5457 1.6894
  • 1.5424
  • 1.690 1.3623
  • 1.1460 *

.7893

  • 1.3313
  • 1.0282
  • 1.3516 ' 1.2627 10 ' 1.1663
  • 7743......1. 5753
  • 1.7060
  • 1.5954 '. 1. 8819
  • 2.6684 *
  • 1.8126
  • 1.5500
  • 1 1.1213
  • 1.1792 *

.6900

  • 11
  • 1.4105
  • 1.2681
  • 1.3484
  • 1.1203
  • 1.2499 1.8897
  • 1.7964
  • 3.0569 *
  • 1. 5261
  • 1. 6908
  • 1.5792 '.1.0199 *........ 1.6718
  • 12 ' 1.2959
  • 1.4041
  • 1.2616
  • 1.2488 *.8429
  • 1.0014 *.8429
  • 1.7307
  • 2.3943 *

............................ 1. 6739

  • 1.8364 1.6723
  • 1.5430
  • 1.7091 *

.6940 *

.5569

  • 13 ' 1.2809
  • 1.2766
  • 1.3623
  • 1.1203
  • 1.0003 1.7302
  • 2.3344
  • 3.3056 *
  • 1.6517
  • 1.6909
  • 1.5966
  • 1.8897
  • 14 *

.9757

  • 1.2574
  • 1.1449
  • 1.1781 *.8429 *

.5550

  • 3.3056
  • 1.8840
  • 1.7972
  • 2.3957 *

. 1 9492

  • 1.6770
  • 15 *

.8450

  • 7454 *

.7883 *

.6897

  • 2.1502
  • 2.6236
  • 2.6702
  • 3.0592
  • M-SUB-Q

APPENDIX Page (Wiof 140 McGuire 2 Cylce 10 Core Operating Limits Report l'able 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations

(

l AT 50% POWER, 200 EFFD, THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m DOTTOM)

...............................e...............**..................A H

G F

E D

C B

8*

.9954

  • 1.4287
  • 1.2895
  • 1.5947
  • 1.4276
  • 1.4587
  • 1.1738
  • 1.0892
  • l
  • ?.0525
  • 1.6084
  • 1.7897
  • 1.4655
  • 1.6305
  • 1.5866
  • 1.8958
  • 2.0181
  • 1.4405
  • 1.4598 *

.8739

  • 9
  • 1.4287
  • 1.2638
  • 1.5433
  • 1.4062
  • 1.5947
  • 1.6094
  • 1.8043
  • 1.4683
  • 1.6181
  • 1.5763
  • 2.5407 *

................... 1. 4818

  • 1.6557
  • 10
  • 1.2895
  • 1.5300
  • 1.2766
  • 1.5476
  • 1.4180
  • 1.5572
  • 1.3034 *

.9002 *

........................................... 5316 *

  • 1.5005
  • 1.6428
  • 1.5020
  • 1.1831
  • 2.

..................... 7421

  • 1.7897
  • 1.4870
  • 1.

11

  • 1.5947
  • 1.4052
  • 1.5444
  • 1.2873
  • 1.4234
  • 1.2574
  • 1.3527
  • 7797 *

.............................**................. 7921

  • 1.6653
  • 2.8841 *
  • 1.4655
  • 1.6573
  • 1.5045
  • 1.7715
  • 1.5732
  • 1........................

.9468

  • 12
  • 1.4276
  • 1.5936
  • 1.4169
  • 1.4223 *

.9393

  • 1.1374
  • 1.6305
  • 1.4688
  • 1.6461..*.1.5754 *........ 1. 7533
  • 1.6105
  • 2.2602
  • l 1.4587
  • 1.4405
  • 1.5562
  • 1.2563
  • 1.1363 *

.7754 *

.6223

  • 13
  • 1.5031
  • 1.7921
  • 1.6182
  • 2.2273
  • 3.1276
  • 1.5866
  • 1.6187
  • 14
  • 1.1738
  • 1.4587
  • 1.3023
  • 1.3516 *

.9457 *

.6223 *

  • 1.8958
  • 1.5781
  • 1.7850
  • 1.6653
  • 2.2615
  • 3.1286
  • 15
  • 1.0892 *

.8729 *

.9002 *

.7786

  • 2.0181
  • 2.5464
  • 2.5338
  • 2.8861.* M-SUB-Q AT 50% POWER, 200 EFFD, THIS IS LEVEL 15 0F 18 (LEVEL 18 : TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

  • 1.5369
  • 1.2681
  • 1.2027 8*

.9350

  • 1.5197
  • 1.3484
  • 1.6943
  • 1.4876 1.8894
  • 1.5068
  • 1.7125
  • 1.6493
  • 1.9901
  • 2.0852 *
  • 2.1673
  • 1 6581 9
  • 1.5197
  • 1.3334
  • 1.6579
  • 1.4726
  • 1.6954
  • 1.5133
  • 1.5637 *

.9436 *

.................. 013

  • 1. 6737 *.**... 1 6152.*. 2.6656..*.

1.7200

  • 1.5
  • 1.6581
  • 1.8902
  • 1 5347 1.6504
  • 1.4908
  • 1.6515
  • 1.3730 *.9618
  • 10
  • 1.3484
  • 1.6515
  • 1.*037
  • 1.8894
  • 1.5402
  • 1.8312
  • 1.5398
  • 1.6992
  • 1.5341
  • 1.8336
  • 2.6108
  • 11
  • 1.6943
  • 1.4716
  • 1.6451
  • 1.3720
  • 1.5165
  • 1.3163
  • 1.4298 *

.8140 *

  • 1. 5050
  • 1.7306
  • 1.5441
  • 1.8427
  • 1.6000
  • 1.8478
  • 1.6985
  • 2. 9827
  • 12
  • 1.4876
  • 1.6954
  • 1.4876
  • 1.5123 *

.9842

  • 1.1963 *

.9864 *

............... 9

  • 1 7006
  • 1. 6113
  • 1.0179
  • 1.6616
  • 2 3421..*.
  • 1.7125
  • 1.501 13
  • 1.5169
  • 1.5123
  • 1.6504
  • 1.3152
  • 1.1963 *

.8065 *

.6458

  • 1.5353
  • 1.0486
  • 1.6613
  • 2.3169
  • 3.2516 *
  • 1.6493
  • 1.6747 14
  • 1.2681
  • 1.5615
  • 1.3720
  • 1.4287 *

.9853 *

.6450 *

  • 1.8356
  • 1.6992
  • 2.3429
  • 3.2541 *
  • 1. 9901
  • 1.6171 15
  • 1.2027 *

.9414 *

.9618 *

.8129

  • 2.0852
  • 2.6714
  • 2.6133
  • 2.9827
  • M-SUB-Q

APPENDIX Page 67 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWEH, 200 EPPD, THIS IS LEVEL 14 0F 10 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F C

B A

...............................E........D 8*

.9328

  • 1.5165
  • 1.3398
  • 7.6890
  • 1.4726
  • 1.5219
  • 1.2584
  • 1.2006 *

............................ 1. 6487

  • 1 8770
  • 1. 8098
  • 2.2058
  • 2.3007
  • 2.3935
  • 1.8237
  • 2.0907
  • 9* 1.5165
  • 1.3313
  • 1.6568
  • 1.4630
  • 1.6890
  • 1.4994
  • 1.5551 *

.9382 *

................... 1. 6946

  • 1. 8959 *............... 1 8244
  • 1.7640
  • 2.9502
  • 1.6330 *
  • 1.8237
  • 2.0869
  • 10
  • 1.3398
  • 1.6504
  • 1.3827
  • 1.6472
  • 1.4823
  • 1.6418
  • 1.3602 *.9532 *

........................................................... 97

  • 2 8492
  • 2.0294
  • 1.6792
  • 1.8468
  • 1.6634
  • 1.98
  • 2.0907
  • 1.7005 11
  • 1.6890
  • 1.4619
  • 1.6418
  • 1.3698
  • 1.5123
  • 1.3045 + 1.4159 *

.8022 *

.... 487

  • 1. 8983 *...... 1. 6837......2. 0219
  • 1. 7656..*.2. 0477
  • 1.8786
  • 3.3028 *
  • 1.6 12
  • 1.4726
  • 1.6879
  • 1.4791
  • 1.5000 *

.9000

  • 1.1856 *

.9725 *

. 1.8770

  • 1.6336
  • 1.8483
  • 1 7605
  • 2.0090
  • 1. 8346
  • 2.5909
  • 13
  • 1.5219
  • 1.4983
  • 1.6400
  • 1.3034
  • 1.1845 *

.7958 *

.6362 *

  • 1.0098
  • 1.8258 *
  • 2.0488
  • 1.8338
  • 2.5736
  • 3.6162 *

................... 1. 6647 14

  • 1.2584
  • 1.5540
  • 1.3500
  • 1.4148 *.9714 *.6362 *

................... 1. 9923

  • 1.8794.*. 2 5925
  • 3.6193
  • 2.2058 ** 1.7654

.9521 *

.8022

  • 1.2006 *

.9361 *

....**...................... 3. 3054..*. M-SUB-Q

  • 2.3007
  • 2.9564
  • 2.8527 AT 50% POWER, 200 EFFD, THIS Is LEV;L 13 0F 18 DOTTOM)

(LEVEL 18 = TOP OF CORE, LEVEL 1 s

H G

B A

......................F.**......E.........D........C 8*

.9500

  • 1.5500
  • 1.3527
  • 1.7232
  • 1.4865
  • 1.5380
  • 1.2659
  • 1.2199 *
  • 2.6204
  • 1.9636
  • 2.2750
  • 1.7753
  • 2.0458
  • 1.9601
  • 2.3711
  • 2.4469
  • 9
  • 1.5500
  • 1.3495
  • 1.6911
  • 1.4801
  • 1.7222
  • 1.5144
  • 1.5008 *

.9457 *

..................................... 1. 7614

  • 1.9868
  • 1.8951
  • 3.1636
  • 1.9636
  • 2.2659
  • 1.8167
  • 2.0610
  • 1.4009
  • 1.6793
  • 1.5026
  • 1.6708
  • 1.3752 *

.9639

  • 1.3527
  • 1.6847 10 *
  • 2.2750
  • 1.8234
  • 2.1933
  • 1.8116
  • 2.0150
  • 1.9024
  • 2.1652 + 3.0786
  • 11
  • 1.7232
  • 1.4700
  • 1.6750
  • 1.3902
  • 1.5455
  • 1.3216
  • 1.4405 *.9086 *
  • 1.7753
  • 2.0630
  • 1.8168
  • 2 1907
  • 1.9106
  • 2.2278
  • 2.0366
  • 3.5974
  • 12
  • 1.4865
  • 1.7211
  • 1.4994
  • 1.5412
  • 1.0003
  • 1.2113 *

.9842 *

. 2.0450

  • 1.7628
  • 2.0168
  • 1.9146
  • 2 2100
  • 2.0037
  • 2.8311
  • 13
  • 1.5380
  • 1.5133
  • 1.6697
  • 1.3205
  • 1.2102 *

.8107 *.6447

  • 1.8038
  • 2.2301
  • 2.0036
  • 2.8470
  • 3.9878
  • 1.9884
  • 1.9601
  • 14
  • 1.2659
  • 1.5707
  • 1.3741
  • 1.4394 *

.9832 *

.6437

  • 2.1674
  • 2.0376
  • 2.8330
  • 3.93d4
  • 2.3711 1.8976 15
  • 1.2199 *

.9436 *

.9628 *

.0075

  • 2.4469
  • 3.1701
  • 3.0800
  • 3.6004
  • M-SUB-Q

APPENDIX Page 68 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% FOWER, 200 EFPD, THIS IS LEVEL 12 OF 18 (LEVEL 18 4 TOP OF CORE, LPVEL 1 = BOTTOM)

H C

F E

D C

B A

8*

.9532

  • 1.5390
  • 1.3355
  • 1.7029
  • 1.4619
  • 1.5112
  • 1.2413
  • 1.1995 *
  • 2.9851
  • 2.2269
  • 2.6014
  • 2.0215
  • 2.3352
  • 2.2362
  • 2.7004
  • 2.7647
  • 9
  • 1.5390
  • 1.3355
  • 1.6718
  • 1.4587
  • 1.6997
  • 1.4876
  • 1.5551 '

.9275 *

  • 2.2269
  • 2.5772
  • 2.06e3
  • 2.3553
  • 1.9992 2.

3.5895 *

.............................................'... 2581..*.2.1526

  • 10
  • 1.3355
  • 1.6654
  • 1.3816
  • 1.6600
  • 1.4812
  • 1.6483
  • 1.3516 *

.9468 '

  • 2.6014 '.2.0760
  • 2.5036
  • 2.0642.*.2.2900
  • 2 0411..*.2.4475
  • 3.4842
  • 11
  • 1.7029
  • 1.4566
  • 1.6547
  • 1.3741
  • 1.5315
  • 1.3045
  • 1.4212 *

.7947 *

............................ 2. 5086

  • 2. 1570
  • 2.5253
  • 2.3105
  • 4.074a *
  • 2.0215
  • 2.3589
  • 2.0701 *
  • 1.2049 *

.9714

  • 12
  • 1.4619
  • 1.6986
  • 1.4769
  • 1.5262
  • 1.0057
  • 2 3352
  • 2.0010
  • 2.2912
  • 2.1603
  • 2 49.95
  • 2.2585
  • 3.2035
  • l 13
  • 1.5112
  • 3.4865
  • 1.6461
  • 1.3034
  • 1.2038 *

.8086 *

.6383 *

  • 2.2362
  • 2.2592
  • 2.0421
  • 2.5267
  • 2.2585
  • 3.2133
  • 4.4948
  • 1.2413
  • 1.5540
  • 1.3505
  • 1.4201 *

.9714 *

.6372

  • 14 '
  • 2.7004
  • 2.1536 *
  • 2.3118
  • 3.2039
  • 4.4955 *

................... 2 4489 15

  • 1.1995 *.9253 *

.9457 *

.7936

  • 2. 7 6 47
  • 3. 5 9 5 8
  • 3.4 87 0
  • 4. 07 4 6
  • M-SUB-Q

....................................n AT 50% POWER, 200 EFPD, THIS IS LEVEL 11 CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTCM)

H G

F E

D C

D A

8*

.9414

  • 1.5133
  • 1.3109
  • 1.6686
  • 1.4287 + 1.4748
  • 1.2102
  • 1.1706 *

........................................ 947

  • 2 5697
  • 3.0905
  • 3.1529 *
  • 3.4676
  • 2.5003
  • 3.0180
  • 2.3302
  • 2.6...............................

9

  • 1.5133 ' 1.3120
  • 1.6400
  • 1.4767
  • 1.L643
  • 1.4523 ' 1.5187

.9039 *

  • 2.5803
  • 2.9912
  • 2.3940
  • 2.7131
  • 2.3057
  • 2. 6126
  • 2.4641
  • 4.0975..*.

10

  • 1.3109 ' 1.6343
  • 1.3537
  • 1.6279
  • 1.4491
  • 1.6140
  • 1.3205 *.9232 *
  • 3.0180
  • 2.4032
  • 2.9020
  • 2.3784
  • 2 6571.*. 2. 3617
  • 2.8270
  • 3.9892'*

11

  • 1.6686
  • 1.4266
  • 1.6236
  • 1.3495
  • 1.5058
  • 1.2700
  • 1.3934 *.7765 *
  • 2.3302 + 2.7164
  • 2.3848
  • 2.8981
  • 2.5001
  • 2.9324
  • 2.6914 4.7310
  • 12
  • 1.4287
  • 1.6633
  • 1.4459
  • 1.5005 *

.9939

  • 1.1888 *

.9543 *

  • 2.6947 2.3001
  • 2.6507
  • 2.5044
  • 2.9013
  • 2.6170
  • 3.7147
  • 13
  • 1.4748
  • 1.4512
  • 1.6119
  • 1.2777
  • 1.1877 *

.0000 *

.6207

  • 2.5697
  • 2.6142
  • 2.3629
  • 2.9360
  • 2.6157
  • 3.7242
  • 5.2084
  • 1.2102
  • 1.5176
  • 1.3195
  • 1.3923 *

.9532 *

.6287

  • 14 *
  • 3.0905
  • 2.4668
  • 2.8306
  • 2.6930
  • 3.7179
  • 5.2094
  • 15
  • 1.1706 *

.9018 *

.9221 *

.7754

.........'............................4.1052

  • 3.9929
  • 4.7310
  • M-SUB-Q 3.1529

APPENDIX Page 69 of 140 McGuire 2 Cylce 10 Core Operating Limits Report l'able 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER, 200 EFPD, THIS IS LEVEL 10 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F C

B A

...............................E.......D R*

.9446

  • 1.5272
  • 1.3141
  • 1.6804
  • 1.4276
  • 1.4748
  • 1.2049
  • 1.1727 *

.............................................. *..370

  • 3 5435
  • 3.5870 '
  • 3.6621
  • 2.7114
  • 3.2707
  • 2.6426
  • 3.0775
  • 2.9 9
  • 1.5272
  • 1.3163
  • 1.6526
  • 1.4290
  • 1.6750
  • 1.4523
  • 1.5251 *

.9007 *

..............**......................... 8179

  • 4.6904
  • 3.0949
  • 2.6283
  • 2.9994
  • 2...............
  • 2.7114
  • 3.1529
  • 2.6897
  • 10
  • 1.3141 ' 1.6461
  • 1.3570
  • 1.6397
  • 1.4523
  • 1.6236
  • 1.3238 *

.9243 *

  • 3.2707
  • 2.6963
  • 3.2602.*.2.7080
  • 3.0340
  • 2.7013.*.3.2512
  • 4.5728
  • 11
  • 1.6804
  • 1.4276
  • 1.6343
  • 1.3559
  • 1.5200
  • 1.2873
  • 1.4073
  • 7775 *
  • 2.6426
  • 3.0993
  • 2.7164
  • 3.1303
  • 2.6815
  • 3.1688
  • 3.0475
  • 5.4566
  • 12
  • 1.4276
  • 1.6740 ' 1.4491 ' 1.5165
  • 1.0025
  • 1.2070 *

.9639 *

  • 3.0775
  • 2 6299.*. 3.0432..*.2.6881.*.3.1393 '.2.8343.+.4 0709.*

13

  • 1.4748
  • 1.4512
  • 1.6226
  • 1.2852
  • 1.2070 *

.8110 *

.6372 *

... 9370

  • 3.0015
  • 2. 7030
  • 3.1734
  • 2.8343
  • 4.0937
  • 5.7733..*
  • 2................

14

  • 1.2049
  • 1.5230
  • 1.3227
  • 1.4062 *

.9628 *

.6372 *

  • 3.0496
  • 4.0746
  • 5.7733 *
  • 3.5435
  • 2.8215..*. 3.2537 15
  • 1.1727 *

.8986 *

.9232 *

.7775

.........................**... 4634

  • M-SUB-Q 3.5870
  • 4.7005
  • 4.5728
  • 5 AT 50% FCWER, 200 EFPD, THIS IS LEVEL 9 OF 18

{ LEVEL 18 TOP OF CCRE, LEVEL 1 : BOTTCM)

H G

F D

C B

A

...............................E..........................................

8*

.9302

  • 1.5069
  • 1.2948
  • 1.6440
  • 1.3955
  • 1.4384
  • 1.1749
  • 1.1417 *
  • 3.8106
  • 2.8306
  • 3.3585
  • 2.6142
  • 3.0517
  • 2.

j

................................................ 9410

  • 3. 5812
  • 3.6005
  • J 9
  • 1.5069
  • 1.3002
  • 1.6215
  • 1.4019
  • 1.6397
  • 1.4201
  • 1.4908 *

.8782 *

  • 2.8306
  • 3.2879
  • 2.6668
  • 3.0538
  • 2.6220
  • 3.0118
  • 2.8565
  • 4.7932
  • 10
  • 1.2948
  • 1.6151
  • 1.3345 ' 1.6100
  • 1.4266
  • 1.5926
  • 1.2981 *

.9029 *

  • 3.3585
  • 2,6782..*. 3.2416
  • 2.6864.*. 3.0327
  • 2.7080 *...................... 3
  • 4.7056..*

3.310 11

  • 1.6440 ' 1.3998
  • 1.6054
  • 1.3380
  • 1.5037
  • 1.2745
  • 1.3880 *

.7647 *

......................................................... 1597

  • 5.6540 *
  • 2.6142
  • 3.0581
  • 2.6947
  • 3.2658
  • 2.7998
  • 3.3103
  • 3................

12

  • 1.3955
  • 1.6386
  • 1.4234
  • 1.4994
  • 1.0025
  • 1.2081 *.9607
  • 3.0390
  • 2.8070
  • 3.2756
  • 2.9589
  • 4.2528 *
  • 3.0517
  • 2.6236

.8193 *

.6405

  • 13
  • 1.4384
  • 1.4191
  • 1.5915
  • 1.2734
  • 1.2081
  • 2.

3.3128

  • 2.9589
  • 4.2694
  • 6.0278 *

... 9410

  • 3.0139
  • 2.7097
  • i 14
  • 1.1749
  • 1.4887
  • 1.2970
  • 1.3869 *.9596 *

.6394 *

  • 3.5812
  • 2.8602
  • 3.3128
  • 3.1643
  • 4.2570
  • 6.0361
  • J

.8761 *

.9018 *

.7647

  • 1.1417 4.7106
  • 5.6613
  • M-SUB-Q
  • 3.6805
  • 4.8037
  • l APPENDIX Page 70 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report 1Dable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 5 0 % Pok'r9, 200 EFFD, THIS IS LEVEL 8 OF 18 e tJP OF CORE, LEVEL 1 = BOTTOM)

(LEVEL,

H G

F C

B A

...............................E.........D.................................

8* 1.0046

  • 1.5679
  • 1.3291
  • 1.6815
  • 1.4137
  • 1.4587
  • 1.1856
  • 1.1599 *

......**.. 2 7506

  • 3.1966
  • 2.4738
  • 2.9116
  • 2.8016
  • 3.3924
  • 3.4323..*
  • 3.7955
  • 9
  • 1.5679
  • 1.3420
  • 1.6665
  • 1.4276
  • 1.6772
  • 1.4448
  • 1.5251 *

.8857 *

............ 1943

  • 2.5237
  • 2.9116
  • 2 4822
  • 2 8715
  • 2.7013
  • 4.5022 *
  • 2.7506
  • 3.

10

  • 1.3291
  • 1.6600
  • 1.3612
  • 1.6526
  • 1.4598
  • 1.6343
  • 1.3259 *

.9170 *

..................... 0803

  • 2.5428..*.2 8847
  • 2.5667
  • 3.1461
  • 4.4159 *
  • 3.1966
  • 2.5340
  • 3 11
  • 1.6815
  • 1.4223
  • 1.6472
  • 1.3616
  • 1.5701
  • 1.3270
  • 1.4394 *

.7829 *

.......................................................... 12

  • 5.3433
  • 3.1147
  • 2.7437
  • 3.2392
  • 2.99
  • 2.4738
  • 2.9155
  • 2.5517 12
  • 1.4137
  • 1.6761
  • 1.4566
  • 1.5647
  • 1.0924
  • 1.3002
  • 1.0121 *
  • 2.9116
  • 2.4836
  • 2.8924
  • 2.7506
  • 3 2780
  • 2 9252
  • 4.1441
  • 13
  • 1.4587
  • 1.4437
  • 1.6322
  • 1.3259
  • 1.3002 *

.8954 *

.6844 *

  • 2.8016
  • 2.8734
  • 2.5682
  • 3.2416
  • 2.9233
  • 4.2446
  • 5.8819
  • 14
  • 1.1956
  • 1.5240
  • 1.3248
  • 1.4304
  • 1.0110 *.6833 *

..... 24

  • 2 7030
  • 3. 1483
  • 2.9933.*. 4.1480
  • 5.8819 *
  • 3.39 15
  • 1.1599 *

.8846 *

.9178 *

.7818

  • 3.4323
  • 4.5115
  • 4.4204
  • 5 3433..* M-SUB-Q AT 50% POWER, 200 EFPD, THIS IS LEVEL 7 CF 18 (LEVEL 18 = TCP OF CORE, LEVEL 1 = BOTTOM)

H C

F E

D C

B A

8

  • 1.1224
  • 1.6215
  • 1.3548
  • 1.6900
  • 1.4137
  • 1.4576
  • 1.1813
  • 1.1578 *

.............................................. 2. 5517

  • 3.0993
  • 3. 1325 *
  • 3.5463
  • 2.5237
  • 2.9351
  • 2.2674
  • 2.6668
  • 9
  • 1.6215
  • 1.3816
  • 1.6847
  • 1.4362
  • 1.6890
  • 1.4501
  • 1.5358 *

.8825 *

  • 2.5237
  • 2.9331
  • 2.3142
  • 2.6604
  • 2.2710
  • 2.6220
  • 4.1168 *

....................................................... 2.4558

  • 10
  • 1.3548
  • 1.6783
  • 1.3730
  • 1.6700
  • 1.4758
  • 1.6504
  • 1.3355 *

.9200 *

  • 2.9351..*. 2.3240
  • 2.8343
  • 2.3290
  • 2.6458
  • 2 3427
  • 2.8602
  • 4.0296
  • 11
  • 1.6900
  • 1.4309
  • 1.6654
  • 1.4126
  • 1.6236
  • 1.3741
  • 1.4726 *

.7915 *

  • 2.2674
  • 2.6733
  • 2.3364..*.2.8584
  • 2. 5428
  • 3.0118
  • 2.7147
  • 4.8624
  • 12
  • 1.4137
  • 1.6858
  • 1.4716
  • 1.6194
  • 1.2906
  • 1.4705
  • 1.0603 *
  • 2.6668
  • 2.2733
  • 2.6522
  • 2.5517
  • 3,0581
  • 2.7215
  • 3.8761
  • 13
  • 1.4576
  • 1.4491
  • 1.6493
  • 1.3730
  • 1.4705 *

.9971 *

.7294 *

  • 2.5517
  • 2.6236
  • 2.3440
  • 3.0118
  • 2.7215
  • 3.9532
  • 5.4977
  • 14
  • 1.1813
  • 1.5347
  • 1.3345
  • 1.4716
  • 1.0592 *

.7294 *

  • 3.8761
  • 5.5046 *
  • 3.0993
  • 2.4585
  • 2.8621.*. 2.7164 15
  • 1.1578 *

.8804 *

.9189 *

.7915

  • 4.1246
  • 4.0333
  • 4.8624
  • M-SUB-Q

APPENDIX Page 71 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1Dable 1 (cont.)

F-sub-Q/M-sub.Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER, 200 EFPD, THIS IS LEVEL 6 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

........................................D.........C.......B........A......

H G

F E

8

  • 1.1920
  • 1.6418
  • 1.3570
  • 1.6697
  • 1.3966
  • 1.4373
  • 1.1642
  • 1.1374 *

... 2273

  • 2 3253
  • 2 7063
  • 2.1039
  • 2.4738
  • 2.3719
  • 2.8847
  • 2.9233 *
  • 3.

9* 1.6418

  • 1.3998
  • 1.6729
  • 1.4255
  • 1.6708
  • 1.4362
  • 1.5197 *

.8686 *

  • 2.3253
  • 2.7013
  • 2.1410
  • 2.4710
  • 2.1080
  • 2.4326
  • 2.2840
  • 3.8421..*

10

  • 1.3570
  • 1.6665
  • 1.3645
  • 1.6600
  • 1.4683
  • 1.6386
  • 1.3259 *

.9082 *

  • 2.7063
  • 2.1504
  • 2 6173.*. 2. 1536
  • 2.4462 + 2.1686.*.2.6506
  • 3.7531.*.

11

  • 1.6697
  • 1.4201
  • 1.6547
  • 1.4201
  • 1.6590
  • 1.3944
  • 1.4758 *

.7883 *

  • 2.1039
  • 2.4752
  • 2. 1611
  • 2.6315
  • 2. 3228
  • 2.7334
  • 2.5035.*. 4.5022
  • 12
  • 1.3966
  • 1.6686
  • 1.4651
  • 1.6547
  • 1.3923
  • 1.5562
  • 1.0839 *
  • 2.4738
  • 2. 1090
  • 2.4516
  • 2 3290
  • 2.7750
  • 2.4822
  • 3.5435.*

13

  • 1.4373
  • 1.4351
  • 1.6376
  • 1.3934
  • 1.5562
  • 1.0635 *.7551 *
  • 2.3719
  • 2.4339
  • 2.1707
  • 2.7368
  • 2.4808
  • 3.6167
  • 5.0475
  • 14
  • 1.1642 + 1.5187
  • 1.3240
  • 1.4748
  • 1.0828 *

.7551 *

.......... 2 2864

  • 2.6538
  • 2 5050
  • 3. 5463
  • 5.0533 *
  • 2.8847 15
  • 1.1374 *

.8664 *

.9071 *

.7883

  • 2.9233
  • 3.8489
  • 3.7564
  • 4.5022
  • M-SUB-Q AT 50% POWER.

200 EFPD, THIS IS LEVEL 5 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

1.2188

  • 1.6847
  • 1.3784
  • 1.6975
  • 1.4105 ' 1,4555
  • 1.1738
  • 1.1535
  • 8 *
  • 2.8417
  • 2.0545
  • 2.4475
  • 1.9043
  • 2.2569
  • 2.1600
  • 2. 6410
  • 2.6651
  • 9
  • 1.6847
  • 1.4309
  • 1.7050
  • 1.4437
  • 1.7007
  • 1.4544
  • 1.5476 *

.87f1

  • 3.52v6 *

................................................. 135

  • 2. 0730 *
  • 2.0545
  • 2.4124
  • 1.9338
  • 2.2500
  • 1.9085
  • 2.2.....

10

  • 1.3784
  • 1.6997
  • 1.3837
  • 1.6911
  • 1.4919
  • 1.6729
  • 1.3473 *

.9200 *

  • 2.4475
  • 1.9415
  • 2.3758
  • 1.9458
  • 2.2169
  • 1.9589
  • 2.4045
  • 3.4216
  • 11
  • 1.6975
  • 1.4304
  • 1.6859
  • 1.4469
  • 1.7125
  • 1.4309
  • 1.5144 *

.0011 *

............ 2534.*. 1.9519

  • 2.3719
  • 2.0421..*. 2.4231..*. 2.2453.*. 4.0861.*.
  • 1.9043
  • 2.

12

  • 1.4105
  • 1.6986
  • 1.4876
  • 1.7072
  • 1.4416
  • 1.6194
  • 1.1171 *
  • 2.2569
  • 1.9102
  • 2.2225
  • 2.0478
  • 2.4448
  • 2.1772
  • 3.1125
  • 13
  • 1.4555
  • 1.4533 + 1.6718
  • 1.4298
  • 1.6194
  • 1.1053 *

.7818 *

  • 2.1600
  • 2.2147
  • 1.9606
  • 2.4258
  • 2.1772
  • 3.2036
  • 4.4655
  • 14
  • 1.1738
  • 1.5465
  • 1.3452
  • 1.5133
  • 1.1160 *

.7818 *

  • 2.6410
  • 2.0750
  • 2 4071
  • 2.2465
  • 3.1147
  • 4.4655
  • j 15
  • 1.1535 *

.8739 *

.9200 *

.0011

  • 2.6651
  • 3.5292
  • 3.4242
  • 4.0861
  • M-SUB-Q 1

APPENDIX Page 72 of 140 McGuire 2 Cylce 10 Core Operating Limits Report l'able 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Nonnal Operations AT 50% POWER, 200 EFPD, THIS IS LEVEL 4 0F 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 a BOTTOM)

.............G.........F.........E...........................B.......A.....

H D

C 8* 1.1910

  • 1.6397
  • 1.3462
  • 1.6472
  • 1.3741
  • 1.4159
  • 1.1438
  • 1.1181
  • 2.68 1.0204
  • 2.1526
  • 2.0652
  • 2.5281
  • 2.5697 *

..... 15

  • 1.9278
  • 2 2924
  • 9
  • 1.6397
  • 1.3977
  • 1.6568
  • 1.4094
  • 1.6504
  • 1.4148
  • 1.5037 *

.8525 *

  • 3.3819 *
  • 1 9278
  • 2.2500
  • 1. 8387
  • 2.1378
  • 1.8249
  • 2.1100
  • 1.9847 10
  • 1.3462
  • 1.6504
  • 1.3495
  • 1.6440
  • 1.4523
  • 1.6301
  • 1.3120 *

.8943

  • 1.8465
  • 2.2489
  • 1.8504
  • 2.1009
  • 1.8654
  • 2.2888
  • 3.2805 *
  • 2.2924 1.6472
  • 1.4030
  • 1.6386
  • 1.4126
  • 1.6686
  • 1.3987
  • 1.4758 *

.7008

  • 11

.............................. 2124

  • 1 9278
  • 2.2745
  • 2.1100
  • 3.8796
  • 1.0204
  • 2.1420
  • 1.8567
  • 2.

12

  • 1.3741
  • 1.6472
  • 1.4491
  • 1.6643
  • 1.4126
  • 1.5851
  • 1.0935 *
  • 2.1526
  • 1.0264
  • 2. 1060
  • 1.9338
  • 2.2864
  • 2 0421
  • 2.9410
  • 13
  • 1.4159
  • 1.4137
  • 1.6279
  • 1.3977
  • 1.5851
  • 1.0860 *

.7668

  • j
  • 4.1957
  • 2.0652
  • 2.1120
  • 1 8670
  • 2.2757
  • 2.0411
  • 2. 9831 l

14

  • 1.1438
  • 1.5026
  • 1.3109
  • 1.4748
  • 1.0924 *

.7668 *

  • 2.5201
  • 1 9865
  • 2.2912
  • 2. 1120
  • 2.9429
  • 4.1957 *

.8504 *

.8932 *

.7008

  • 1.1181
  • 2.5697
  • 3.387 3.8830
  • M-SUB-Q

............... 1

  • 3.2929 *

)

AT 50% POWER, 200 EFPD, THIS IS LEVEL 3 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 : BOTTOM) l H

G F

E D

B A

.................................................C........................

8

  • 1.1652
  • 1.6022
  • 1.3195
  • 1.6119
  • 1.3473
  • 1.3891
  • 1.1192
  • 1.0892 *
  • ........................................ 62
  • 1.9856
  • 2.4421
  • 2.4978.*.

2.1664

  • 1.7463
  • 2.06 1.8091
  • 2.4879 9
  • 1.6022 ' 1.3677
  • 1.6204
  • 1.3827
  • 1.6108
  • 1.3805
  • 1.4651 *

.6332 *

  • 1 8091
  • 2.1131
  • 1.7554
  • 2.0402
  • 1.7540
  • 2.0288
  • 1 9135
  • 3.2756
  • 10
  • 1.3195
  • 1.6151
  • 1.3227
  • 1.6076
  • 1.4191
  • 1.5894
  • 1.2798 *

.871.8

  • 2.1664
  • 1.7610
  • 2. 1431
  • 1.7696
  • 2.0065
  • 1. 7891
  • 2.1991
  • 3.1757 *

]

11

  • 1.6119 + 1.3773
  • 1.6011
  • 1.3816
  • 1.6268
  • 1.3645
  • 1,4373 *

.7604

  • 3.7339 *
  • 1.7463
  • 2.0488
  • 1.7753
  • 2.0949
  • 1. 8098
  • 2.1431
  • 2.0148
  • 1.3473
  • 1.6006
  • 1.4148
  • 1.6226
  • 1.3794
  • 1.5465
  • 1.0667
  • 12

............................................ 1 9295

  • 2.7645
  • 0662
  • 1.7554
  • 2.0111
  • 1.8143
  • 2.1568 *
  • 24 1.3805
  • 1.5872
  • 1.3634
  • 1.5465
  • 1.0603 *

.7465

  • 1.3891 13 1.7906
  • 2.1452
  • 1.9295
  • 2.8398
  • 3.9929
  • 1.9856
  • 2.0307 14
  • 1.1192
  • 1.4641
  • 1.2788
  • 1.4362
  • 1.0667
  • 7465
  • 2.4421
  • 1.9152
  • 2.2013
  • 2.0157
  • 2 7662
  • 3.9929 *

.7593

  • 1.0892 *

.8311 *

.8707 '

  • 2.4979
  • 3.2905
  • 3.1780
  • 3.7339
  • M-SUB-Q

APPENDIX Page 73 of 140 McGuire 2 Cylce 10 Core Operating Limits Report

' fable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER, 200 EFPD, THIS IS LEVEL 2 OF 18 (LEVEL 18 = TOP OF CORE. LEVEL 1 = BOTTOM)

....H.........G.........F........*E*........D.....**..C........B.........A....

8

  • 1.0710
  • 1.4533
  • 1.2092
  • 1.4705
  • 1.2381
  • 1.2584
  • 1.0153 *

.9596 *

. 2 5562

  • 1.8790
  • 2.2339
  • 1 8264
  • 2.1515
  • 2.0999.*. 2.5849
  • 2.7266
  • 9
  • 1.4533
  • 1.2466
  • 1.4748
  • 1.2756
  • 1.4651
  • 1.2477
  • 1.2991 *

.7561 *

  • 1 8790
  • 2.1870..*.1.8333
  • 2.1090
  • 1 8380
  • 2.1441.*.2. 0633..*. 3.4704
  • 10
  • 1.2092
  • 1.4694
  • 1.2156
  • 1.4469
  • 1.2906
  • 1.4223
  • 1.1481 *

.7765 *

........ 192

  • 1.8694
  • 2. 0969
  • 1.9077
  • 2.3389
  • 3.4135.*
  • 2. 2339
  • 1. 8387
  • 2.2..............

11

  • 1.4705
  • 1.2702
  • 1.4426
  • 1.2616
  • 1.4662
  • 1.2274
  • 1.2670 *

.6758 *

  • 1. 8264
  • 2. 1172..*.1. 8750
  • 2. 1686
  • 1. 8953
  • 2.2546
  • 2 1643
  • 4.0002.*

12

  • 1.2381
  • 1.4630
  • 1.2873
  • 1.4630
  • 1.2424
  • 1.3677 *

.9521 *

  • 2.1515..*.1.8403
  • 2. 1019
  • 1.8994
  • 2.2453
  • 2.0459
  • 2.9272..*

i 13

  • 1.2584
  • 1.2466
  • 1.4212
  • 1.2263
  • 1.3687 *

.9521 *

.6640

  • i
  • 2.0999
  • 2.1452
  • 1.9093
  • 2.2569
  • 2.044

.......................................... 9..*.2.9549

  • 4.2160
  • 14
  • 1.0153
  • 1.2981
  • 1.1470
  • 1.2659 *

.9510 *

.6640 *

  • 2.5849
  • 2.0642
  • 2.3414
  • 2.1653
  • 2 9272
  • 4.2160
  • 15 *

.9596 *

.7551 *

.7765 *

.6758

...........3.4759

  • 3.4162
  • 4.0002 *. M-SUB-Q
  • 2.7266
  • l i

AT 50% POWER, 200 EFPD, THIS IS LEVEL 1 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.7722

  • 1.0207 *

.3418

  • 1.0464 *

.8761 *.8589 *

.7047 *

.6094 *

  • 3,3976
  • 2.5637
  • 3.0993
  • 2.4794
  • 2.9509
  • 2.9892
  • 3.6407
  • 4.1837
  • 9
  • 1.0207 *

.8547

  • 1.0421 *.9211
  • 1.0464 *

.8343 *

.8750 *

.5237 *

.................................................................. 8678

  • 3.0603
  • 2.5035
  • 2.8306
  • 2.4893
  • 3.1059
  • 2.9529
  • 4.
  • 2.5637
  • 10 *

.8418

  • 1.0378 *

.8514

  • 1.0517 *

.8889 *

.9982 *

.7551 *

.5141

  • 3.0645
  • 2.4893
  • 2.9429
  • 2.6205
  • 3.4431
  • 5.0128 *
  • 3.0993
  • 2.5107

.9178

  • 1.C474 *

.8718

  • 1.0292 *

.8290 *

.8279 *

.4530

  • 11
  • 1.0464

............ 2.4992

  • 3.0243
  • 2.5833..*. 3 2107
  • 3.2036
  • 5.7733 *
  • 2.8398 *
  • 2.4794 12 *

.8761

  • 1.0442 *

.8868

  • 1.0271 *.8429 *.9082 *.6351 *
  • 2.9509
  • 2.4935
  • 2.9509
  • 2.5910
  • 3 1896
  • 2.9709
  • 4. 2323
  • 13 *

.8589 *

.8343 *

.9982 *

.8279 *.9093 *

.6522 *

.4434 *

  • 2.9892
  • 3.1059
  • 2.6220
  • 3.213 6.0865 *

..**............................. 0

  • 2.9709
  • 4.1520
  • 14 *

.7047 *

.8739 *

.7540 *

.8268 *.6351 *

.4434

  • 3.6407
  • 2.9549
  • 3.4458
  • 3.2036
  • 4.2364
  • 6.0949
  • 15 *

.6094 *

.5237 *.5130 *

.4530

  • 4.1837
  • 4.8732
  • 5.0185
  • 5.7733
  • M-SUB-Q

~

APPENDIX Page 74 of 140 McGuire 2 Cylce 10 Core Operating Limits Report l'able 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER, 405 EFPD, THIS IS LEVEL 18 OF 18 (LEVEL 18 : TCP OF CORE, LEVEL 1 = BOTTOM)

...................................................................A......

H G

F E

D C

B

.9436

  • 1.1899
  • 1.0721
  • 1.0057 *

.7336 *

.5923

  • 8*

.6876

  • 1.0121
  • 2.3503
  • 1.9772
  • 2.1365
  • 1.7672
  • 1 9811.*.2.0300
  • 2.3254
  • 2.6490
  • 9
  • 1.0121 *

.8729

  • 1.0742
  • 1.0603
  • 1.1888
  • 1.0100 *

.9939 *

.6330 *

  • 1.9772
  • 2.2043
  • 1.8069 *

............................ 1. 9607 *...... 1 7808

  • 2. 1081
  • 2. 0314
  • 3.0302
  • 10 *

.9436

  • 1.0742 *

.7936

  • 1.1130
  • 1.0324
  • 1.1545 *

.9211 *

.6629 *

............................................. 346

  • 2.2934
  • 3 1454
  • 1.0128
  • 2.0912
  • 1.8069
  • 2.0531
  • 1.8

. 2. 1365 *

.9510 *

.9939 *

.6148

  • 11
  • 1.1899
  • 1.0603
  • 1.1128 *

.9211

  • 1.0017

................... 1 8118

  • 2. 1553
  • 1 9282
  • 2.1846
  • 2.0888
  • 3.3814 *
  • 1.7672
  • 1.9623
  • 12
  • 1.0721
  • 1.1899
  • 1.0335
  • 1.0817 *

.7500 *

.8932 *

.7540 *

................ 0944

  • 2. 7107
  • 2.1683
  • 2
  • 1.9811
  • 1.7808
  • 2.0521

.............................. 9291

  • 1 1.0110
  • 1.1545 *

.9510 *

.8932 *

.6490 *

.5430

  • 13
  • 1.0057
  • 3.692
  • 2.0300
  • 2.1079
  • 1 0338
  • 2 1846
  • 2.0944
  • 2.7487.....................................

5..*

.9939 *

.9211 *

.9939 *

.7540 *

.5430

  • 14 *

.7336

............. 324..*.2.2922...*.2.0878

  • 2.7105
  • 3.6925 *
  • 2.3254
  • 2.0

.5923 *

.6330 *

.6629 *

.6148

  • 3.1479
  • 3.3785
  • M-SUB-Q
  • 2.6490 AT 50% POWER, 405 EFPD, THIS IS LEVEL 17 OF 18 (LEVEL 18 = TOP OF CCRE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

i I

1.2873 *

.9104 *

.7947

  • 1.4698
  • 1.3441 8*

.8204

  • 1.2745
  • 1.1877 *
  • 2.0176
  • 1.6299
  • 1.7675
  • 1.4668
  • 1.6443
  • 1.6549
  • 1.9171
  • 2.0460
  • 9
  • 1.2745
  • 1.1181
  • 1.3537
  • 1.3109
  • 1.4919
  • 1.3238
  • 1.3184 *

.0000 *

................... 1.4978

  • 1.6509
  • 1.4813
  • 1 6782
  • 1.6362
  • 2.4951 *
  • 1.6299
  • 1.8017
  • 10
  • 1.1877
  • 1.3548 *

.9693

  • 1.4073
  • 1.3334
  • 1.4566
  • 1.2209 *

.8771 *

  • 1.7675
  • 1.5020
  • 1.7

...................... 126

  • 1.5310
  • 1.6694
  • 1.5259
  • 1.8151.*. 2.4892
  • 1.4062
  • 1.1781
  • 1.3655
  • 1.2338
  • 1.3152 *

.0022

  • 11
  • 1.4898
  • 1.3109
  • 1.4668
  • 1.6516
  • 1. 5331......1. 7453
  • 1.6063
  • 1 7695
  • 1 6639
  • 2 7216
  • 12
  • 1.3441
  • 1.4930
  • 1.3345
  • 1.3655 *

.9211

  • 1.1599 *

.9810 *

.............................................. 1 6852

  • 2.1861 *
  • 1.6443
  • 1.4810
  • 1.6681
  • 1.6068
  • 1.7943
  • 1.3238
  • 1.4566
  • 1.2338
  • 1.1610 *.8461 *

.7090

  • 13
  • 1.2873
  • 1.6549
  • 1.6764
  • 1.5253
  • 1.7695
  • 1.6845
  • 2.2353
  • 2.9684
  • 14 *

.9104

  • 1.3184
  • 1.2209
  • 1.3163 *

.9810 *

.7090 *

  • 1 9171
  • 1.6375
  • 1.8144
  • 1 6638
  • 2 1861
  • 2.9684 *

.0022

.7947

  • 7990 *

.8771 *

  • 2.0460
  • 2.4982
  • 2.4898
  • 2.7214
  • M-SUB-Q a

APPENDIX Page 75 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER, 405 EPPD, THIB IS LEVEL 16 OF 18 (LEVEL 18 : TOP CF CCRE, LEVEL 1 = BOTTOM)

H G

D C

B A

......................F.........E..........................**.............

8*

.8643

  • 1.3741 + 1.2509
  • 1.6119
  • 1.4148
  • 1.3794 *

.9596 *

.8697 *

  • 2.0111
  • 1.5944
  • 1.7846
  • 1.4394
  • 1.6557
  • 1.6509
  • 1.9397
  • 2.0074
  • 9
  • 1.3741
  • 1.1845
  • 1.4662
  • 1.3837
  • 1.6140
  • 1.4084
  • 1.4266 *

.8450 *

................... 1.4697

  • 1. 6592
  • 1. 4508
  • 1. 6671
  • 1. 6005
  • 2.5141..*.
  • 1.5944
  • 1.8106
  • 10
  • 1.2509
  • 1.4662
  • 1.0292
  • 1.5219
  • 1.4201
  • 1.5733
  • 1.3023 *.9425 *
  • 1. 7846
  • 1.4735..*.1. 7194.*.1. 4988
  • 1 6574
  • 1. 4944
  • 1.0023
  • 2 4607
  • 11
  • 1.6119
  • 1.3837 + 1.5208
  • 1.2456
  • 1.4673
  • 1.3066
  • 1.4201 *

.8525 *

  • 1. 4394......1.6603
  • 1.5027
  • 1. 7444
  • 1.5692
  • 1. 7657
  • 1.6282
  • 2.7063
  • 12
  • 1.4148
  • 1.6140
  • 1.4201
  • 1.4673 *

.9714

  • 1.2381
  • 1.0370 *

................................ 14 *...... 7945

  • 1.6561...*.2.1004
  • 1.6557
  • 1.4508
  • 1.6587
  • 1.57 1

13

  • 1.3794
  • 1.4094
  • 1.5733
  • 1.3066
  • 1.2381 *

.8889 *

.7476 *

............... 5

  • 1.4938
  • 1. 7656
  • 1.6555
  • 2.2298
  • 2.9717 1.6509
  • 1.667 14 *

.9596

  • 1.4276
  • 1.3023
  • 1.4201
  • 1.0378
  • 7476 *

.......... 15

  • 1 8015
  • 1 6281
  • 2.1804..*.2. 9717

... 9397

  • 1.60.....
  • 1.

15 *

.8697 *

.8450 *

.9425 *. 8 52 5

............ 5172...*.2 4611

  • 2.7047
  • M-SUB-Q
  • 2.0074 *2.

AT 5 0 % POWER. 405 EFFD, THIS IS LEVEL 15 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

D C

D A

......................F........E

.8793

  • 1.4100
  • 1.2713
  • 1.6590
  • 1.4319
  • 1.4084 *

.9842 *.9211

  • 8 *

....... 7734..*.1 7622

  • 2. 0948
  • 2.1350 *

.......... 1. 6760

  • 1 9257
  • 1. 5187 *
  • 2.0931
  • 1 9
  • 1.4180
  • 1.2134
  • 1.5133
  • 1.4073
  • 1.6590
  • 1.4287
  • 1.4641 *

.8600

  • 1.6760
  • 1.9416
  • 1.5582
  • 1.7749
  • 1.5270
  • 1.7750
  • 1.6865
  • 2.7061
  • 10
  • 1.2713
  • 1.5144
  • 1.0656
  • 1.5669
  • 1.4384
  • 1.6065
  • 1.3195 *.9553 *

.... 257

  • 1.5622
  • 1.8478
  • 1.5725
  • 1.7625
  • 1.5865
  • 1.9321
  • 2.6110
  • 1.9 11
  • 1.6590
  • 1.4073
  • 1.5658
  • 1.2681
  • 1.4876
  • 1.3120
  • 1.4384 *

.8579 *

............................... 35

  • 1.6612
  • 1.9027
  • 1 7368
  • 2.9115 *
  • 1.5187
  • 1.7757
  • 1.5772
  • 1.86......................................

12

  • 1.4319
  • 1.6590
  • 1.4394
  • 1.4876 *

.9768

  • 1.2424
  • 1.0367 *

......................................................... 3561

  • 1.6632
  • 1.9257
  • 1.7614
  • 2
  • 1.7734
  • 1.5201
  • 1.7647
  • 13
  • 1.4084
  • 1.4298
  • 1.6065
  • 1.3120
  • 1.2434 *

.8804 *

.7411

  • 1.7622
  • 1.7750
  • 1.5959
  • 1.9018
  • 1.7607
  • 2.3988
  • 3.2049
  • 14 *

.9842

  • 1.4641
  • 1.3195
  • 1.4384
  • 1.0357 *.7411 *

............ 6872

  • 1.9312
  • 1.7361..*.2.3561
  • 3.2054 *
  • 2.0948
  • 1.

15 *

.9211

.8600 *

.9553 *

.8579

  • 2.1350
  • 2. 7100
  • 2. 6126
  • 2.9095
  • M-SUB-Q

1 1

l APPENDtX Page 76 of 140 McGuire 2 Cylce 10 Core Operating Limits Report liable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations 1

AT 50% POWER, 405 EFPD, THIS IS LEVEL 14 0F 18 (LEVEL 18 2 TOP OF CORE, LEVEL 1 = BOTTOM)

H C

F E

C B

A

........................................D.................................

8*

.8761

  • 1.4201
  • 1.2702
  • 1.6403
  • 1.4126
  • 1.3998
  • 1.0581
  • 1.0164
  • 2.3364
  • 1.8669
  • 2.1699
  • 1. 6923
  • 1.9790
  • 1. 9666
  • 2.3535
  • 2.3876 9
  • 1.4201
  • 1.2231
  • 1.5326
  • 1.3987
  • 1.6440
  • 1.4105
  • 1.4566 *

.8654

  • 3.0376 *

.............................................. 1.9727

  • 1.8724
  • 1.0669
  • 2.1682
  • 1.7489
  • 1.9839
  • 1.6958
  • 10
  • 1.2702
  • 1.5315
  • 1.1524
  • 1.5647
  • 1.4159
  • 1.5776
  • 1.3002 *.9436 *
  • 2.1699
  • 1 7539
  • 2.0000
  • 1.7545
  • 1.9609
  • 1.7762
  • 2.1356
  • 2.8938
  • 11
  • 1.6483
  • 1.3907
  • 1,5626
  • 1.2788
  • 1.4501
  • 1.2734
  • 1.3987 *

.8354

..................**................... 8538

  • 2.1799
  • 1.9813
  • 3.3143 *
  • 1.6923
  • 1.9849
  • 1.7594
  • 2.0880
  • 1 12
  • 1.4126
  • 1.6451
  • 1.4148
  • 1.4501 *

.9543

  • 1.1963 *

.9960 *

  • 1. 9790
  • 1.6961
  • 1.9633
  • 1. 8567
  • 2.1663
  • 1 9830
  • 2. 7156
  • 13
  • 1.3998
  • 1.4105
  • 1.5776
  • 1.2734
  • 1.1963 *

.8418 *

.7079 *

....................... 1788

  • 1.9826..*. 2.7151
  • 3.6254
  • 1.7762
  • 2.

1.9717

  • 1.9666
  • a 1.4566
  • 1.3002
  • 1.3987 *

.9950 *

.7079

  • 14
  • 1.0581 *

............................ 1.9804

  • 2.7156
  • 3.6254 *
  • 2.3535
  • 1.0732
  • 2.1356 *

.8654 *

.9436 *

.8354

  • 1.0164
  • 2.3876
  • 3.0 3.3143
  • M-SUB-Q

............. 413

  • 2.8938
  • AT 50% POWER, 405 EFPD, THIS IS LEVEL 13 0F 18 (LEVEL '.8

= TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

]

8*

.8986

  • 1.4750
  • 1.3109
  • 1.7007
  • 1.4394
  • 1.4459
  • 1.1781
  • 1.1620 *

................... 44

  • 2. 1809
  • 2.1514
  • 2.5548
  • 2.5603
  • 2.3795
  • 1.84

............ 07;8

  • 2.5223
  • 2 i

l 9* 1.4758

  • i.2766
  • 1.6215
  • 1.4351
  • 1.6922
  • 1.4394
  • 1.5197 *.9253 *
  • 2.0238 2.3692
  • 1.9026
  • 2.1802
  • 1.8520 *

....... 31

  • 3.27

.........'..................................... 2 1737

  • 2.0316
  • 10
  • 1.3109
  • 1.6204
  • 1.3345
  • 1.6301
  • 1.4480
  • 1.6086
  • 1.3270 *

.9000 *

  • 2 3795..*. 1.9081
  • 2. 2775
  • 1. 9079
  • 2. 1639..*.1. 9516
  • 2 3518
  • 3.1527
  • 11
  • 1.7007
  • 1.4351
  • 1.6258
  • 1.3484
  • 1.4919
  • 1.2777
  • 1.4137 *

.8418 *

.......... 13

  • 1 9135
  • 2.2931
  • 2.0254
  • 2.4244
  • 2.2029.*. 3.6870 *
  • 2.18
  • 1. 8444 12
  • 1.4394
  • 1.6922
  • 1.4459
  • 1.4898 *.9596
  • 1.1952 *.9917 *
  • 2.1809
  • 1.8528.*. 2.1661.*.2.0283
  • 2.4027
  • 2.1900
  • 3.0252
  • 13
  • 1.4459
  • 1.4394
  • 1.6086
  • 1. i/88
  • 1.1952 *.8322 *

.7004 *

  • 2.1514
  • 2.1733
  • 1.9516
  • 2.4244
  • 2.1089
  • 3.0206
  • 4.0220
  • i 14
  • 1.1781
  • 1.5197
  • 1.3270
  • 1.4137 *

.9917 *

.7004 *

  • 2.5548
  • 2.0323
  • 2.3531
  • 2.2028
  • 3.0272
  • 4.0220
  • 15
  • 1.1620 *

.9243 *

.9800 *

.8418

  • 2.5603
  • 3.2772
  • 3.1534
  • 3.6841.* M-SUB-Q

APPENDIX Page 77 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% FOWER, 405 EFFD, THIS IS LEVEL 12 OF 18 (LEVEL 18 : TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F B

A

...............................E.........D.........C l

l I

8*

.8996

  • 1.4855
  • 1.3141
  • 1.7007
  • 1.4319
  • 1.4491
  • 1.2124
  • 1.2102
  • 3.*.2. 5017
  • 2.4618.*. 2.9065
  • 2.8874 2.106
  • .2.8580.*.2.2916............... 2. 7730
  • 1.4341
  • 1.6890
  • 1.4309
  • 1.5305 *

.9468

  • 9* 1.4855
  • 1.2948
  • 1.6461

................ 1169

  • 2.4901..*. 2.3151.*.3.7119 *
  • 2.4993
  • 2

..................... 1701 2.2916

  • 2.6891
  • 2 f

10

  • 1.3141
  • 1.6418
  • 1.3687
  • 1.6408
  • 1.4405
  • 1.5979
  • 1.3195 *

.9842

  • 3.582
  • 2. 7230
  • 2. 1765
  • 2 6029
  • 2.1823.+. 2. 4889
  • 2.2230
  • 2.6747 *..........***................

9..*.

j

[

11

  • 1.7007
  • 1.4330
  • 1.6365
  • 1.3591
  • 1.4876
  • 1.2563
  • 1.3944 *

.8311

  • 2.7477
  • 2.5182
  • 4.1957
  • l
  • 2 1063
  • 2.5007
  • 2.1889
  • 2.6306.*. 2 2901 l

12

  • 1.4319
  • 1.6890
  • 1.4384
  • 1.4855 *

.9468

  • 1.1706 *

.9693 *

  • 2.7152 2.4639
  • 3.4149
  • l
  • 2.5017
  • 2.1196
  • 2.4917... 2. 2937..............'...................

13

  • 1.4491
  • 1.4309
  • 1.5979
  • 1.2563
  • 1.1706 *

.8107 *.6822 *

  • 2 4618
  • 2.4900
  • 2 2219
  • 2. 7477..... 2. 4625
  • 3 3961
  • 4.5243
  • 14
  • 1.2124
  • 1.5294
  • 1.3195
  • 1.3944 *

.9693 *

.6812

  • 2.9065
  • 2.3159 * ?.6747
  • 2.5169
  • 3.4149
  • 4.5245
  • l

..............................a........................

(

15

  • 1.2102 *

.9457 *

.9842 *

.8311

............. 171..*.3.5829

  • 4.1919
  • M-SUB-Q
  • 2.8874 ' 3.7 l

l i

AT 50% F0WER, 405 EFPD, THIS IS LEVEL 11 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTCM)

......................F..................D.......C........B........A.....

H G

E 8*

.8921 ' 1.4694

  • 1.2970
  • 1.6750
  • 1.4073
  • 1.4266
  • 1.2027
  • 1.2070
  • 3.3147 2.6450
  • 3.1827
  • 2.4392
  • 2.8924
  • 2.8325
  • 3.3303
  • 4.2921
  • l 9
  • 1.4694
  • 1.2820
  • 1.6290
  • 1.4116 ' 1.6611
  • 1.4041
  • 1.5090 *

.9393

  • 3.1081
  • 2.5296
  • 2.8962
  • 2.4472
  • 2.8749
  • 2.6467
  • 4.2354 *

'.2.6458 *

  • 1.3548
  • 1.6172 ' 1.4137 ' 1.5679
  • 1.2959 *

.9714

  • 10
  • 1.2970
  • 1.6247

.................................... 2 8826

  • 2 5720
  • 3.0832
  • 4. 0849.*.
  • 3.1827
  • 2.5304
  • 3.0411
  • 2.5300
  • 11
  • 1.6750
  • 1.4105
  • 1.6129
  • 1.3388
  • 1.4619
  • 1.2284
  • 1.3655 *

.8140 *

............................................ 1734 '. 2.9299

  • 4. 8597
  • 3.0390
  • 2.6426
  • 3.
  • 2. 4392
  • 2.8981
  • 2.5381
  • 12
  • 1.4073
  • 1.6611 ' 1.4116
  • 1.4598 *

.9296

  • 1.1428 *.9446 *

................... 2. 8845

  • 2. 6458
  • 3.1325
  • 2.8343
  • 3.9319 *
  • 2.8924
  • 2.4472
  • 1.5679
  • 1.2284 ' 1.1428 *

.7904 *.6640 '

13

  • 1.4266
  • 1.4041
  • 2.8325
  • 2.8749
  • 2.57s0 3.9038
  • 5.1973 *

...........................'. 3.1734

  • 2.8343
  • 14
  • 1.2027
  • 1.5090
  • 1.2948
  • 1.3655 *

.9446 *

.6640 *

  • 3.3303
  • 2.6482
  • 3.0852
  • 2.9299
  • 3.9354
  • 5.2035
  • 15
  • 1.2070 *

.9302 *

.9714 *

.8140

  • 4.0885
  • 4.8597

.........'..........................'. M-SUB-Q l

1 l

l 1

l l

l l

APPENDIX l

Page 78 of 140 McGuire 2 Cylce 10 Core Operating Limits Report ifable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER, 405 EFPD, THIS IS LEVEL 10 CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

E D

A

......................F...........................C........D 8*

.9007

  • 1.4758
  • 1.2927
  • 1.6793
  • 1.4009
  • 1.4234
  • 1.2006
  • 1.2156 *
  • 3.5486
  • 2.8528
  • 3 4275
  • 2.7198
  • 3. 2464
  • 3.1757............................ 51.*.
  • 3.7435
  • 3.66 9
  • 1.4750
  • 1.2790
  • 1.6343
  • 1.4052
  • 1.6633
  • 1.3966
  • 1.5123 *

.9414 *

  • 2.8528 3.3637 *2

.........'........... 8070

  • 3.2440
  • 2. 7402.*.3.2416
  • 2.9770
  • 4.7464
  • 10
  • 1.2927
  • 1.6290
  • 1.3516
  • 1.6215
  • 1.4062
  • 1.5690
  • 1.2927 *

.9725 *

  • 3.4275...*.2.8161
  • 3.3619
  • 2.8252..*.3.2464

.................. 4870

  • 4.6065 *
  • 2.8943
  • 3 11
  • 1.6783
  • 1.4041
  • 1.6172
  • 1.3345
  • 1.4630
  • 1.2220
  • 1.3655 *

.8110 *

  • 2.7198
  • 3.2464
  • 2.8343
  • 3

.............................. 3103

  • 2.8828
  • 3.4814 '.3.2953
  • 5.5115..*

12

  • 1.4009
  • 1.6622
  • 1.4052 + 1.4608 *

.9350 ' 1.1470 *

.9436 *

  • 3.246

...... 4..*.2.7402

  • 3.2488
  • 2.8867
  • 3.4458
  • 3.1147
  • 4.3328
  • 13
  • 1.4234
  • 1.3966
  • 1.5690
  • 1.2220
  • 1.1470 *.7925 *

.6629 *

  • 3.1757
  • 3.2416 2
  • 4.3243
  • 5.7657 *
  • ..................'.. 8943
  • 3.4814
  • 3.1147 14
  • 1.2006
  • 1.5123
  • 1.2927
  • 1.3655 *

.9425 *.6619

  • 3.7435
  • 2.9790
  • 3.4870
  • 3.
  • .............................. 2953
  • 4.3328
  • 5.7657 15
  • 1.2156

.9403 *

.9725 *.8118

  • 3.6651.*.4.7567 4.6065
  • 5.5115
  • M-SUB-Q AT 50% FOWER, 405 EFPD, THIS IS LEVEL 9 0F 18

( LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM) l H

G F

E D

C B

A i

8 *

.8868

  • 1.4351 + 1.2541
  • 1.6250
  • 1.3570
  • 1.3784 1.1652
  • 1.1813 *
  • 3.8547
  • 3. 0753
  • 3.6190
  • 2.7963
  • 3.3304
  • 3.2707..............................................

25..*.3.8220

  • l
  • 3.86 l

l 9

  • 1.4351
  • 1.2445
  • 1.5840
  • 1.3634
  • 1.6100
  • 1.3527
  • 1.4673 *

.9136 *

... 0753

  • 3.6167
  • 3.
  • 2.8810 *

........................ 3.3220

  • 2. 8233
  • 3.3483
  • 3.0927
  • 4.9392
  • i 10
  • 1.2541
  • 1.5797
  • 1.3120
  • 1.5712
  • 1.3634
  • 1.5197
  • 1.2541 *.9436 *
  • 3.6190 2.8886
  • 3.4676
  • 2.9078
  • 3.3380
  • 3.0015
  • 3.6227

.........'........................................................ 7984 *

  • 4 11
  • 1.6258
  • 1.3623
  • 1.5669
  • 1.2959
  • 1.4201
  • 1.1877
  • 1.3259 *

.7893

  • l
  • 2.7963
  • 3.3254
  • 2.9155
  • 3.5349
  • 3.1059
  • 3.7307
  • 3.

......................................................... 4594.*. 5.7886

  • l 12
  • 1.3570
  • 1.6097 + 1.3612
  • 1.4180 *.9200
  • 1.1203 *

.9189 *

  • 3.3304
  • 2.8233
  • 3.3431
  • 3.

.............................. 1081 *.......................'.........

3.6961

  • 3.3300 4.6211
  • l 13
  • 1.3784
  • 1.3537
  • 1.5197
  • 1.1877
  • 1.1203 *

.7775 *

.6469 *

  • 3.2707
  • 3.3483
  • 3.00 3

....................... 15

  • 3.7339 *............... 3355
  • 4.6065
  • 6 0865..*

14

  • 1.1652
  • 1.4673
  • 1.2541
  • 1.3270 *

.9178 *

.6469 *

  • 3.8625
  • 3.09

.............. 27..**.. 6257 3

  • 3.4594
  • 4.62

................... 11.*.6.0949

  • l 15
  • 1.1813 *.9125 *

.9436 '

.7893

  • 4.9448
  • 4.7984
  • 5.7886
  • M-SUB-Q

i APPENDIX Page 79 of l40 McGuire 2 Cylce 10 Core Operating Limits Report Table 1 (cont.)

l F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Nonnal Operations AT 50% PCWER, 405 EFFD, THIS IS LEVEL 8 0F 18 (LEVEL 18 = TOP OF CCRE, LEVEL 1 = BO'fr0M)

..........................................................B........A H

G F

E D

C 8*

.8900

  • 1.4469
  • 1.2531
  • 1.6354
  • 1.3559
  • 1.3805
  • 1.1652
  • 1.1910 *

.............................. 3.5406 *

  • 3.0818
  • 3.6257 *

................................. 2

  • 3.1597 3.5300
  • 2.0472
  • 3.3870
  • 2.644 i

9

  • 1.4469
  • 1.2456
  • 1.5947
  • 1.3623
  • 1.6204
  • 1.3537
  • 1.4700 *

.9168

  • 2.8472
  • 3.3585
  • 2.7198
  • 3.1551
  • 2.6684
  • 3.

................................................ 1643

  • 2. 8962
  • 4 5968
  • 10
  • 1.2531
  • 1.5904
  • 1.3130
  • 1.5840
  • 1.3645
  • 1.5315
  • 1.2595 *

.9489 *

......................................3

  • 3. 4003...*.4.4609..*

3.2426

  • 2.7420
  • 3.1597
  • 2.823
  • 3.3870
  • 2. 7266
  • 11
  • 1.6354
  • 1.3612
  • 1.5797
  • 1.2991
  • 1.4309
  • 1.1931
  • 1.3398 *

.7925 *

.......... 7488

  • 3. 2928
  • 2.8602
  • 3.4377 *........................ 154
  • 5.3761.*

3.2

  • 2.6442.*.3.1574 2.......

1.3634

  • 1.4298 *

.9264

  • 1.1363 *

.9275

  • 12
  • 1.3559
  • 1.6204

..................... 1643

  • 2.8640
  • 3 4109
  • 3.0603
  • 4.2241..*

3.1597

  • 2.6684
  • 3 1.5315
  • 1.1931
  • 1.1363 *

.7893 *

.6555

  • 13
  • 1.3805
  • 1.3537
  • 3.0818
  • 3.1620
  • 2.8233
  • 3.4377
  • 3.0603
  • 4.2119
  • 5.5747 1.1652
  • 1.4780
  • 1.2595
  • 1.3398 *

.9275 *

.6555

  • 14 *

........**.............................. 241

  • 5.5747 3.6257
  • 2.8962
  • 3.4003
  • 3.2154
  • 4.2 15
  • 1.1910 *

.9157 *

.9489

  • 7925
  • 3.5406
  • 4.6016
  • 4.4609
  • 5.3761
  • M-SUB-Q AT 50% F0WER, 405 EFPD, THIS IS LEVEL 7 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 : BOTTOM)

H G

F E

D C

B A

8*

.8868

  • 1.4426
  • 1.2424
  • 1.6236
  • 1.3420
  • 1.3666
  • 1.1524
  • 1.1824 *

.............................................. 2. 7198

  • 3.2060
  • 3.1258
  • 3.2293
  • 2.5788
  • 2.9832
  • 2.3265
  • 2.7891
  • 9
  • 1.4426
  • 1.2370
  • 1.5862
  • 1.3516
  • 1.6108
  • 1.3420
  • 1.4694 *

.9082 *

  • 2.5768
  • 3.0496
  • 2 3913..*.2,7838
  • 2 3477
  • 2.7909
  • 2 5502..*. 4 0633
  • 10
  • 1.2424
  • 1.5819
  • 1.3034
  • 1.5776
  • 1..'548
  • 1.5251
  • 1.2520 *

.9425 *

  • 2.9832
  • 2.3979
  • 2.8533
  • 2.4085
  • 2.7838
  • 2.4008
  • 2.9953
  • 3.9354.*.

11

  • 1.6236
  • 1.3484
  • 1.5733
  • 1.2938
  • 1.4287
  • 1.1910
  • 1.3388 *.7904 *
  • 2.3265
  • 2.7838
  • 2.4138
  • 2.9331
  • 2 6033
  • 3.1303
  • 2.8306
  • 4.7361 12
  • 1.3420
  • 1.6097
  • 1.3537
  • 1.4266 *

.9275

  • 1.1449 *

.9318 *

  • 2.7891
  • 2.3477
  • 2.7874
  • 2.6064
  • 3.1214
  • 2.7945
  • 3.8625
  • 13
  • 1.3666
  • 1.3420
  • 1.5251
  • 1.1910
  • 1.1449 *

.7979 *

.6619

  • 5.1004 *
  • 2.7198
  • 2.7909
  • 2.4808
  • 3.1281
  • 2.7927
  • 3.8557
  • 14
  • 1.1524
  • 1.4694
  • 1.2520
  • 1.3388 *

.9318 *

.6619

  • 3.2060
  • 2.5517
  • 2.9974
  • 2.8306
  • 3.8625
  • 5.1064
  • 15
  • 1.1824 *

.9071 *

.9425 *

.7904

  • 3.1258
  • 4.0709
  • 3.9354
  • 4.7361
  • M-SUB-Q l

APPENDIX Page 80 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report 1?able 1 (cont.)

F-sub-Q/M sub-Q Values (F-sub-Q OP Margin)- Normal Operations AT 50% POWER, 405 EFPD, THIS IS LEVEL 6 0F 18 (LE* VEL 18 = TOP OF CORE, LEVEL 1 DOTTCM)

H G

E D

C B

A

......................V...................................................

8*

.8964

  • 1.4416 ' 1.2338
  • 1.6022
  • 1.3227
  • 1.3462
  • 1.1363
  • 1.1642 *

........ 8215 *

  • 2......

'.2.1182

  • 2.3081.................

2.6994.*. 2. 0929

  • 2.5078
  • 2.4489
  • 2. 8867
  • 1.3377
  • 1.5904
  • 1.3240
  • 1.4512 *

.8954

  • 9* 1.4416
  • 1.2327
  • 1.5701 1..*. 2.1462..*. 2.4992
  • 2.1090 '.2.5093.*.2 2948
  • 3.6602 *
  • 2.713
  • 2.3001 10
  • 1.2330
  • 1.5658
  • 1.2916 ' 1.5626
  • 1.3430
  • 1.5123
  • 1.2402 *

.9307 *

.......... 2. 1515

  • 2.5795..*. 2 1600
  • 2.4964
  • 2.2259..*.2 6897
  • 3 5463 *
  • 2.6994
  • 1.6022 ' 1.3355
  • 1.5583
  • 1.2906
  • 1.4298
  • 1.1952
  • 1.3366
  • 7861
  • 11 '

................. 21 '.2.5310

  • 4.2487
  • 2.3265
  • 2.78
  • 2. 0929
  • 2.5007
  • 2. 1664.+. 2.6236 12
  • 1.3227
  • 1.5904
  • 1.3420
  • 1.4276 *

.9457

  • 1.1685 *

.9436 '

3.4485 *

'.2 5078

  • 2.1100 *.... 2 4992
  • 2.3302.'.2. 7945
  • 2. 5007 13
  • 1.3462
  • 1.3259 ' 1.5123
  • 1.1952
  • 1.1685 *

.8247 *

.6779 *

................... 2. 2259

  • 2 7821..*. 2.4992.'.3 4622
  • 4.5728 *
  • 2.4489
  • 2.5093
  • 14
  • 1.1363
  • 1.4501
  • 1.2402
  • 1.3366 *

.9436 *

.6779 *

...... 2. 2948

  • 2.6897...............2. 5310 + 3.4465..*.4 5728 *

'. 2. 8867

.7861

  • 1.1642 *

.8943 *

.9307

  • 2487......M-SUB-Q 3.5463
  • 4

.'............. 44

  • 2.8215
  • 3.67 AT 50% POWER, 405 EFPD, THIS IS LEVEL 5 OF 18 ILEVEL 10 = TOP OF CORE. LEVEL 1 = BOTTOM)

H E

B A

e............G........F..................D........C 8*

1.0025

  • 1.5165 ' 1.2766
  • 1.6429
  • 1.3473
  • 1.3762
  • 1.1567
  • 1.1920
  • 2.3596
  • 1.0403
  • 2.2203
  • 2.1643
  • 2.5607
  • 2.4893 +
  • 2.4962
  • 1.9847 1.3698
  • 1.6343
  • 1.3559
  • 1.4898 *.9136
  • 1.6183
  • 9
  • 1.5165
  • 1.2841 1.9847
  • 2.3578
  • 1.8814
  • 2.2057 + 1.0520 2.2150
  • 2.0176
  • 3.2400
  • 1.3805
  • 1.5637 ' 1.2745 *.9543
  • 10
  • 1.2766
  • 1.6140
  • 1.3248
  • 1.6151 *

...............'.................................... 2. 3668 *........... 1

  • 1.8863 2.2490
  • 1.8895
  • 2.1969
  • 1.9484
  • 3.128

. 2. 3596 +

1.6108

  • 1.3398
  • 1.5000
  • 1.2563
  • 1.3955 *

.8118

  • 1.6429
  • 1.3677 11

....................,................ 1.9919

  • 2. 4032
  • 2.2024
  • 3. 7339
  • 1.0403
  • 2.2102
  • 1.8944
  • 2.2912
  • 12 ' 1.3473
  • 1.6343
  • 1.3794
  • 1.5049
  • 1.0753
  • 1.2973
  • 1.0057 *

................................................... 6.*.2.9569

  • 2.2203
  • 1.8527
  • 2.1991
  • 1.9946
  • 2.4178
  • 2.152 1.2873 *.9232 *

.7347

  • 1.3762
  • 1.1559
  • 1.5647 1.2563 13 '

.........'...................................'..... 4.'.3.9460.'.

  • 2.1643 2.2147
  • 1.9476
  • 2.4045
  • 2.1515 2.997

.7347

  • 1.4898
  • 1.2745
  • 1.3955
  • 1.0057 14 ' 1.1567 2.0176
  • 2.3668
  • 2.2024
  • 2.9589
  • 3.9460 *
  • 2 5607 15
  • 1.1920 *

.9125 '

.9543 *.8118

  • 3.7339 M-SUB-Q
  • 2.4893
  • 3.2537

APPENDIX Page 81 of 140 McGuire 2 Cylce 10 Core Operating Limits Report lnable 1 (cont.)

F-sub-Q/M-sub Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER, 405 EFFD, THIS IS LEVEL 4 OF 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 = BOTTCH)

F E

B A

....H.........G...........................D.......C 8

  • 1.1213
  • 1.5594
  • 1.2927
  • 1.6322
  • 1.3409
  • 1.3677
  • 1.1524
  • 1.1824 *
  • 2 3264 '. 1.8181.*. 2 1635
  • 1. 7001
  • 2.0497
  • 2.0001.*.2. 3642.*.2.*.3118
  • 9
  • 1.5594
  • 1.3120
  • 1.6172
  • 1.3709
  • 1.6279
  • 1.3548
  • 1.4855 *

.9104 *

,.1 0181.*. 2.1441.*.1. 7297

  • 2. 0241
  • 1.7081
  • 2.0392
  • 1. 8622
  • 1.0077
  • 10
  • 1.2927
  • 1.6129
  • 1.3280
  • 1.6161
  • 1.3869
  • 1.5701
  • 1.2788 *

.9532 *

................................. 2 1718

  • 2 8886
  • 1.7366
  • 2.0130
  • 1.7869 *

................... 2 0904 *

  • 2.1635
  • 1.7338
  • 1.3591
  • 1.5562
  • 1.2916
  • 1.4148 *

.8182

  • 11
  • 1.6322
  • 1.3687
  • 1.6097 *

.................................................. 70

  • 1. 9937
  • 3.4109 *
  • 1.7001
  • 2.0288
  • 1.7407
  • 2.0691
  • 1.8249
  • 2.18...........**.......

12

  • 1.3409
  • 1.6279
  • 1.3848
  • 1.5540
  • 1.2499
  • 1.4148
  • 1.0464
  • 1.7081
  • 2.0139
  • 1.8280
  • 2.1935
  • 1.9545
  • 2.7063 *
  • 2.0497 13
  • 1.3677
  • 1.3548
  • 1.5701
  • 1.2916
  • 1.4148 ' 1.0132 *

.7765 *

............... 2 1659

  • 1. 9536
  • 2.7131
  • 3.5900.*

1.7862 *

  • 2.0001.*.2 0383
  • 14 + 1.1524
  • 1.4855
  • 1.2788
  • 1.4148
  • 1.0464 *

.7765 *

..................................... 2. 7063

  • 3.5900
  • 1.8622
  • 2.1718
  • 1.9937
  • 2.3642 15
  • 1.1824 *

.9093 *

.9532 *

.8182

  • 3.01 3.4199
  • N.SUB-Q

.'............. 18

  • 2.8886
  • AT 50% POWER, 405 EFPD, THIS IS LEVEL 3 OF 18 (LEVEL 18 = TOP CF CORE, LEVEL 1 s BOTTCM)

H G

A

......................F.........E.......D.......C.......B 8

  • 1.1727
  • 1.5990
  • 1.3130
  • 1.6440
  • 1.3516
  • 1.3827
  • 1.1652
  • 1.1931
  • 4..........

1557

  • 1.9052
  • 1.8559
  • 2.1980
  • 2.

..... 1.6514..*.1.9955

  • 1.5787 *
  • 2 1233
  • 9* 1.5990
  • 1.3430
  • 1.6333
  • 1.3000
  • 1.6429
  • 1.3698
  • 1.5026 *.9211 *

........ 5838

  • 1.8895.'.1.7277
  • 2.7981 *
  • 1

.............................. 8718 1.6514

  • 1.9580
  • 1.5907
  • 1 10
  • 1.3130
  • 1.6290
  • 1.3420
  • 1.6365
  • 1.4041
  • 1.5947
  • 1.2991 *.9650 *

................... 1.9389 *.......... 6042

  • 1 8582
  • 1.6458
  • 2.0047
  • 2. 6831
  • 1.9955
  • 1.6030
  • 1

,8322

  • 11
  • 1.6440
  • 1.3848
  • 1.6311
  • 1.3848
  • 1.6065
  • 1.3302
  • 1.446)

................... 1.6083

  • 1.9002
  • 1. 6508
  • 1.9865
  • 1 0287
  • 3.1574
  • 1.5787
  • 1.8758
  • 12
  • 1.3516
  • 1.6429
  • 1.4030
  • 1.6044
  • 1.3280
  • 1.4973
  • 1.0860 *

........ 5838

  • 1.8598
  • 1.6526.*. 1.9964
  • 1.7789
  • 2.4489 *
  • 1. 9052
  • 1 1.3698
  • 1.5947
  • 1.3302
  • 1.4983 + 1.0731 *.8140
  • 13
  • 1.3827
  • 3.2829
  • 1.6452
  • 1.9865
  • 1.7702
  • 2.4879
  • 1.0559
  • 1.8807
  • 1.1652
  • 1.5015
  • 1.2991
  • 1.4469
  • 1.0860 *

.8140

  • 14 *

.................... 200

  • 2.4489
  • 3.2829 *
  • 2.0056
  • 1.8

... 1980 '.1.7277 2.

15

  • 1.1931 *

.9200 *

.9650 *

.8322

  • 2 1557
  • 2.7998
  • 2.6831.*. 3.1574..* M-SUB-0

[.

I APPENDIX Page 82 of 140 McGuire 2 Cylce 10 Core Operating Limits Report

' fable 1 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Normal Operations AT 50% POWER, 405 EFFD.

THIS IS LEVEL 2 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

1.1192

  • 1.5026
  • 1.2456
  • 1.5401
  • 1.2841
  • 1.3077
  • 1.1106
  • 1.1085
  • 8 *

................................. 1. 9211.*. 1.8806. *. 2.2169.*. 2.2327 *

  • 1.6716
  • 1.9982
  • 1.6107 *

... 2428

  • 2
    • v 9
  • 1.5026
  • 1.2745
  • 1.5305
  • 1.3195
  • 1.5412
  • 1.2938
  • 1.4062 *

.8739 *

........ 89

  • 2 8343
  • 1.76

..... 16

  • 1.9677
  • 1. 6268
  • 1.0806
  • 1. 6136.*. 1.9160 *
  • 1.67 1.5262
  • 1.2702
  • 1.5300
  • 1.3270
  • 1.4983
  • 1.2274 *

.9061

  • 10
  • 1.2456

............ 6311

  • 1. 9571
  • 1 6274
  • 1.9766
  • 1 6703
  • 2.0335
  • 2.7488 *
  • 1.9982
  • 1 11
  • 1.5401
  • 1.3173
  • 1.5326
  • 1.3109
  • 1.5176
  • 1.2638
  • 1.3527 *

.7840 *

...... * *........ * *.... 1. 9110

  • 1. 67 0 3
  • 2. 0 0 2 8
  • 1. 8 67 0
  • 3. 215 4
  • 1.8838
  • 1.6323 *

... 6107

  • 1.

12

  • 1.2841
  • 1.5401
  • 1.3259
  • 1.5155
  • 1.2702
  • 1.4201
  • 1.0314

... 9211..*. 1 6136

  • 1 8782
  • 1. 6722
  • 1.9964
  • 1.7972
  • 2.4752 *
  • 1...

13

  • 1.3077
  • 1.2938
  • 1.4983
  • 1.2638
  • 1.4212
  • 1.0271 *

.7743 *

  • 1 8806
  • 1.9160
  • 1.6703
  • 2.0028
  • 1.7965
  • 2.4879
  • 3.3103
  • 14
  • 1.1106
  • 1.4062
  • 1.2263
  • 1.3537
  • 1.0314 *

.7743 *

. 2.2169

  • 1 7609
  • 2. 0335
  • 1 0670
  • 2.4752
  • 3.3103
  • 15
  • 1.1085 *

.8739 *

.9061

  • 7850
  • 2.
  • 2.8380
  • 2.7488
  • 3.2130
  • M-SUB-Q

... 2327 AT 50% POWER, 405 EFPD, THIS IS LEVEL 1 OF 18 (LEVEL 18 = TOP OF CORE. LEVEL 1 = BOTTOM)

.............................**........D.........C..................A H

C F

E B

1.1063 *

.9264

  • 1.1374 *

.9703 *

.9693 *

.8322 *

.7679

  • 8*

.8557 *

  • 2.8380
  • 2.1925
  • 2.6080
  • 2.1172.*. 2.4780
  • 2.4700
  • 2 8924
  • 3.1529
  • 9
  • 1.1063 *

.9403

  • 1.1310
  • 1.0132
  • 1.1417 *

.9403

  • 1.0185 *

.6565 *

  • 2.1925
  • 2.5788
  • 2.1368
  • 2.3835
  • 2. 1151..*. 2.5682
  • 2.3809
  • 3.6930
  • 10 *

.9264

  • 1.1267 *

.9436

  • 1.1470 *

.9821

  • 1.1074 *

.8814 *

.6490 *

  • 2.6080..*. 2.1452
  • 2 5607
  • 2.1120
  • 2.4654
  • 2.1936
  • 2 7592
  • 3.7564
  • 11
  • 3.1374
  • 1.0110
  • 1.1449 *

.9671

  • 1.1245 *

.9318 *

.9639 *

.5708 *

  • 2.5592
  • 4.3072 *
  • 2.1172
  • 2.3874
  • 2.1172
  • 2. 5136
  • 2.1794.*. 2.6347 12 *

.9703

  • 1.1417 *.9810
  • 1.1224 *

.9414

  • 1.0324
  • 7518 *

..................... 4682

  • 2.1826
  • 2 6283
  • 2.4111
  • 3.3153
  • 2.4780
  • 2.1172
  • 2.

.9693 *

.9403

  • 1.1074 *.9318
  • 1.0335 *

.7658 *

.5601

  • 13 *
  • 2.4700
  • 2.5682
  • 2.1936
  • 2.6347
  • 2.4098
  • 3.2609
  • 4.4746
  • 14 *

.8322

  • 1.0185 *

.8814 *

.9639 *

.7518 *

.5601 *

  • 2.8924
  • 2.3809
  • 2.7610
  • 2.5592
  • 3.3153
  • 4.4746
  • 15 *

.7679 *

.6565 *

.6490 *

.5719

  • 3.1529
  • 3.6961
  • 3.7564
  • 4.3072
  • M-SUB-Q

)

i J

APPENDIX Page 83 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Efable 2 Faub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 100% FOWER, 4 EFFD, THIS IS LEVEL 18 0F 18 (LEVEL 18 : TOP OF CORE, LEVEL 1 = BO7 TOM)

..................... **.*................................D........A.....

H G

F E

D C

7947 *

.6919 *

.5623

  • 8*

.6255 *

.8375 *

.7465 *

.9050 *

.8032 *

... 2381.*. 1.8381.*.2.0790..*.1 6943.*.1 90.33.*. 1.9074

  • 2.1818
  • 2.6500.*
  • 2.

.5162 *

.7604 *

.7797

  • 9*

.8375 *

.7304 *

.8814 *

.8075 *

.9007 *

...... 0091..*. 1.9368

  • 2 8952
  • 2...

1.8301

  • 2.1194
  • 1.7651
  • 1.9051
  • 1.7

..............................**....... 010

  • 10 *

.7465 *

.8814 *

.7604 *

.8825 *

.7722 *

.8514 *

.6919 *

.4841 *

..................... 0504.*. 1. 7671..*. 2 0201..*.1.8234.*. 2. 2149

  • 3.1239 *
  • 2.0790
  • 1.7656
  • 2..

.9050 *.6065 *

.8793 *

.7379 *

.8193 *

.6940 *

.6908 *

.4198

  • 11 1.6943
  • 1.9056
  • 1.7733
  • 2.1252
  • 1.8413
  • 2.1887
  • 2.2454
  • 3.6861
  • 8172 *

.6137 *

.6651 *.5430

  • 12 *

.8032 *

.9007 *

.7711

................. 1445...*.2.0386

  • 2. 7328
  • 1.0447 *2.

................... 2. 0227

  • 1.9033
  • 1.7010 *

.7593 *

.8514 *

.6929 *

.6651 *

.4916 *

.3738

  • 13 *

.7947

  • 1.9074
  • 2.0001..'.1 0250
  • 2. 1903..*.2 0386
  • 2.6600
  • 3. 8290..*.

14 *

.6919 *.77e6 *

.6919 *

.6897 *

.5430 *

.3738 *

  • 2.1818..*. 1.9307
  • 2 2173
  • 2.2471
  • 2. 7328
  • 3.8298
  • 15 *

.5623 *

.5152 *

.4830 *

.4198

  • 3.6880
  • M-SUB-Q

.......... 2.8993

  • 2.6500 AT 100% POWER, 4 EFPD, THIS IS LEVEL 17 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

...................................................................A.....

H G

F E

D C

B 8*

.8804

  • 1.1192
  • 1.0292
  • 1.1492
  • 1.0913
  • 1.1545 *.9896 *

.8771 *

.......... 1.4560

  • 1. 6000 *...... 1 3962
  • 1.4528
  • 1. 3629
  • 1.5772
  • 1.7655..*.
  • 1.7428
  • 9
  • 1.1192
  • 1.0367
  • 1.1513
  • 1.0667
  • 1.1556
  • 1.1256
  • 1.1171 *

.7465 *

...................... 052.*.1.4965

  • 1.3682
  • 1.4021
  • 1. 4115
  • 2.0773 *
  • 1.4560
  • 1.5575
  • 1.4..............................................

10

  • 1.0292
  • 1.1481
  • 1.0217
  • 1.1353
  • 1.0913
  • 1.1470
  • 1.0228 *

.7229 *

............... 1 4865

  • 1. 4040
  • 1.5637
  • 2 1714
  • 1.4245 *

.......... 1. 4093

  • 1. 5885 *
  • 1.6008
  • 11
  • 1.1492
  • 1.0667
  • 1.1331
  • 1.0228
  • 1.1042
  • 1.0239
  • 1.0453 *

.6340 *

..............**... 1 4285

  • 1.5879
  • 1 4562
  • 1. 5594
  • 1.5395
  • 2. 5410 *
  • 1.1862
  • 1.4979
  • 1.0903
  • 1.1031 *

.9116

  • 1.0207 *

.8311

  • 12
  • 1.0913
  • 1.1567

.....................**....... 4583

  • 1. 5433
  • 1.4686
  • 1 8861 1.4876
  • 1 1.4528
  • 1.3661 13
  • 1.1545
  • 1.1256
  • 1.1470
  • 1.0228
  • 1.0217
  • 7754 *

.5719

  • 1.8936
  • 2.6635 *
  • 1. 3629
  • 1.4028
  • 1.4049
  • 1.5605
  • 1. 4676
  • 14 *

.9896

  • 1.1160
  • 1.0217
  • 1.0453 *.8311 *

.5719

  • 1.5772
  • 1.4135
  • 1.5657
  • 1.540
  • 2.6659
  • 6..*. 1.8861 15 *

.8771 *

.7443 *

.7229 *

.6330

  • 2.5442
  • M-SUB-Q
  • 1.7655
  • 2.0821 I

APPENDIX Page 84 of 140 McGuire 2 Cylce 10 Core Operating Limits Report

' fable 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 100% POWER, 4 EFPD, THIS IS LEVEL 16 0F 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 BOTTOM)

H G

D C

D A

......................F..**e....E............*.............................

8

  • 1.0228
  • 1.2820
  • 1.1470
  • 1.3023
  • 1.2124
  • 1.3323
  • 1.1374
  • 1.0496 *

................... 1.5108

  • 1.2761
  • 1. 3631.*. 1. 2300
  • 1.4277
  • 1.5333
  • 1.6539
  • 1.3406
  • 9* 1.2B20
  • 1.1749
  • 1.2991
  • 1.1867
  • 1.3388
  • 1.2959
  • 1.3184 *

.8622 *

... 3406

  • 1. 4563
  • 1.3026
  • 1. 4124.*. 1 2321
  • 1 2692
  • 1.2461.*.1 8709..*.
  • 1 10
  • 1.1470
  • 1.2948
  • 1.1256
  • 1.2938
  • 1.2509
  • 1.3355
  • 1.2017 *

.8514 *

  • 1.5108
  • 1.3069
  • 1.5095
  • 1.3094.*.1.3587
  • 1.2614 *................................ 5.*

1.3903

  • 1.921..

11

  • 1.3023
  • 1.1935
  • 1.2895
  • 1.1524
  • 1.3077
  • 1.2049
  • 1.2745 *

.7518 *

................. 129

  • 1 4761
  • 1.2988
  • 1.4017 *............................... 3268
  • 2. 2394
  • 1.3 1
  • 1. 2761
  • 1.4137
  • 12
  • 1.2124
  • 1.3388
  • 1.2509
  • 1.3066
  • 1.1781
  • 1.2723
  • 1.0067 *
  • 1.6546 *

.......... 1. 2304 + 1.3599

  • 1.3004
  • 1. 3904..*. 1.2917 1.3631
  • 13
  • 1.3323
  • 1.2959
  • 1.3345
  • 1.2038
  • 1.2723 *

.9596 *

.6908 *

.....................**........ 026

  • 1.2909
  • 1.6871.*. 2.3625..*.
  • 1.2300
  • 1.2692
  • 1.2623
  • 1.4.....................

14

  • 1.1374
  • 1.3163
  • 1.2006
  • 1.2734
  • 1.0057 *

.6897 *

..................... 3922

  • 1.3277
  • 1.6550
  • 2.3625 *
  • 1.4277
  • 1.2476
  • 1 15
  • 1.0496 *

.8600 *

.8504 *.7500

  • 1.5333
  • 1.8760
  • 1.9250
  • 2.2442
  • M-SUB-Q AT 100% POWER, 4 EFFD. THIS IS LEVEL 15 0F 18

)

(LEVEL 10 TOP OF CORE, LEVEL 1 = BOTTOM)

H C

F E

D C

B A

8

  • 1.0913
  • 1.3816
  • 1.2145
  • 1.4009
  • 1.2873
  • 1.4362
  • 1.2242
  • 1.1503 *
  • 1. 6545
  • 1.3152.*. 1.5011
  • 1.2454
  • 1.3447
  • 1. 1972
  • 1. 3916
  • 1.4655
  • 9
  • 1.3816
  • 1.2563
  • 1.3944
  • 1.2713
  • 1.4619
  • 1.3966
  • 1.4448 *.9296 *
  • 1.3152
  • 1.4452
  • 1.2754..*.1.3973.*.1.1934
  • 1.2359
  • 1 1916
  • 1.8201
  • 10
  • 1.2145
  • 1.3902
  • 1.1910
  • 1.3998
  • 1.3570
  • 1.4598
  • 1.3141 *

.9264 *

...................... 005

  • 1. 2719
  • 1. 3187
  • 1.2121
  • 1.3334
  • 1.8520 *
  • 1.5011
  • 1.2794
  • 1.5...........................................

11

  • 1.4009
  • 1.2670
  • 1.3955
  • 1.2456
  • 1.4459
  • 1.3259
  • 1.4244 *

.8225

  • 1.2548
  • 2.1500 *
  • 1.2454
  • 1.3985
  • 1.2754
  • 1. 4454
  • 1.2428
  • 1.3499
  • 12
  • 1.2873
  • t.4608
  • 1.3570
  • 1.4437
  • 1.3080
  • 1.4290
  • 1.1192 *

........................ 1

  • 1.2446
  • 1.3416
  • 1.2307
  • 1.5819 *
  • 1.3447
  • 1.1919
  • 1.320.......................................

1.3248

  • 1.4309
  • 1.0742
  • 7647 13
  • 1.4362
  • 1.19(o
  • 1.4587
  • 1.1972
  • 1.2366
  • 1. 2127
  • 1 3511.*.1 2300
  • 1.6209
  • 2.2000
  • 1.3130
  • 1.4234
  • 1.1181 *

.7636

  • 14
  • 1.2242
  • 1.4437
  • 1.3916
  • 1.1929
  • 1.3351
  • 1.2556
  • 1.5823
  • 2.2800
  • 15
  • 1.1503 *

.9275 *

.9253 *

.8204

  • 1.8248
  • 1.0548
  • 2.1544
  • M-SUB-Q

F, l

APPENDIX J

Page 85 of 140 McGuire 2 Cylce 10 Core Operating Limits Report lnable 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 100% POWER, 4 EFPD, THIS IS LEVEL 14 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

......................F.........E.........D.......C.......B.........A......

H G

8* 1.1063

  • 1.4084
  • 1.2306
  • 1.4319
  • 1.3109
  • 1.4683 ' 1.2509
  • 1.1792 *

.... 198

  • 1.3563..*.1.5471
  • 1. 2000
  • 1 3947
  • 1.2373
  • 1.4391
  • 1.5092
  • 1,7 9
  • 1.4084
  • 1.2766
  • 1.4212
  • 1.2981
  • 1.5069
  • 1.4309
  • 1.4887 *

.9478

  • 1.8861 *
  • 1.3563
  • 1.4954
  • 1.3211..*. 1. 4479
  • 1.2302
  • 1.2775
  • 1.2217
  • 10
  • 1.2306
  • 1.4169
  • 1.2102
  • 1.4373
  • 1.3955
  • 1.5058
  • 1.3559 *

.9500 *

....................................'... 3518

  • 1 2405
  • 1.3655
  • 1.9104 *
  • 1.5471
  • 1.3254
  • 1.5601
  • 1.3084 1

11

  • 1.4319
  • 1.2938
  • 1.4330
  • 1.2809
  • 1.5015
  • 1.3741
  • 1.4812 *

.8472 *

................... 1. 3126

  • 1. 4781.*. 1 2592
  • 1. 3719
  • 1 2679..*.2.2003
  • 1.2800
  • 1.4508
  • 12
  • 1.3109
  • 1.5058
  • 1.3955
  • 1.4994
  • 1.3602
  • 1.4919
  • 1.1610 *

............................ 1.2608

  • 1. 3686
  • 1.2498
  • 1.6105 *
  • 1.3947
  • 1.0281
  • 1.3521
  • 13
  • 1,4683
  • 1.4298
  • 1.5048 ' 1.3720
  • 1.4930
  • 1.1181 *.7915 *
  • 1.2373
  • 1. 2777......1. 2414.*. 1.3720
  • 1. 2491
  • 1.6564
  • 2.3376
  • 1.2509
  • 1.4865
  • 1.3537
  • 1.4801
  • 1.1599 *

.7915

  • 14
  • 1.4391
  • 1.2237
  • 1.3672
  • 1.2687
  • 1.6107
  • 2.3402
  • 15
  • 1.1792 *

.9457 *

.9489 *

.8450

............. 910

  • 1.9121.*. 2. 2048
  • M-SUB-Q 1.5092
  • 1.8 AT 100% POWER, 4 EFFD, THIS IS LEVEL 13 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

A

........................................D........C.......B 8* 1.1438

  • 1.4726
  • 1.2766 ' 1.5015
  • 1.3655
  • 1.5412
  • 1.3066
  • 1.2424 *

................... 1. 5652

  • 1 3033
  • 1.4234
  • 1.2529
  • 1 4656.*. 1 5238 *
  • 1.7522
  • 1.3570
  • 9
  • 1.4726
  • 1.3270
  • 1.4698
  • 1.3580
  • 1.5904
  • 1.5026
  • 1.5712 *

.9885 *

  • 1.3570
  • 1.5064
  • 1.3325
  • 1.4626
  • 1 2416
  • 1 2953
  • 1.2284
  • 1. 9229
  • 10
  • 1.2766
  • 1.4833
  • 1.2584
  • 1.5112
  • 1.4673
  • 1.5915 ' 1.4276 *

.9950

  • 1.3139
  • 1.3528
  • 1.2429
  • 1.3715
  • 1.9330 *
  • 1.5652
  • 1.3375
  • 1.5821 11
  • 1.5015
  • 1.3537
  • 1.5058
  • 1.3441
  • 1.5904
  • 1.4512
  • 1.5754 *

.8879 *

  • 1.3033
  • 1.4675
  • 1.3179
  • 1.4806
  • 1 2468
  • 1.3652
  • 1.2486
  • 2 2056
  • 1 f

12

  • 1.3655
  • 1.5894
  • 1.4662
  • 1.5883
  • 1.4384
  • 1.5872
  • 1.2274 *
  • 1.3779
  • i

.............. 1.2472

  • 1.6061..*.

..............s.............

482

  • 1.2417
  • 1.3541
  • 1.2
  • 1 4234 1.5412
  • 1 6015
  • 1.5894
  • 1.4491
  • 1.5872
  • 1.1813 *

.8322 *

{

13 *

  • 1.2529
  • 1.2960 *
  • 1.3664
  • 1.2465
  • 1.6723
  • 2.3599 *

................... 1.2437 i

1.5690

  • 1.4266
  • 1.5744
  • 1.2263 *

.8311

  • 14
  • 1.306
  • 1.4656
  • 1.2300
  • 1.3726
  • 1.2493
  • 1.6073
  • 2.3625
  • 15
  • 1.2424 *

.9864 *

.9939 *

.8857

  • 1.9279
  • 1.9352
  • 2.2100
  • M-SUB-Q i

(

1 a

,i APPENDIX Page EWiof 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 2 (cont.)

' F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 100% POWER, 4 EFPD, THIS IS LEVEL 12 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

....H.........G.........F.........E.........D........C........B.........A.....

8

  • 1.1513
  • 1.4930
  • 1.2906
  • 1.5262
  • 1.3848
  • 1.5690
  • 1.3259
  • 1.2616 *

... 8330

  • 1. 4089
  • 1 6280.*. 1. 3560.*. 1. 4882.*.1. 3065
  • 1 5330..*.1 5935..*.
  • 1...................

9

  • 1.4930
  • 1.3420
  • 1.5133
  • 1.3794
  • 1.6226
  • 1.5283
  • 1.6022
  • 1,0003 *
  • 1.4089
  • 1. 5693 *.1. 3782
  • 1. 5141.*. 1. 2797
  • 1.3512..*. 1. 2750
  • 2. 0172...*

10

  • 1.2906
  • 1.5069
  • 1.2745
  • 1.5422
  • 1.4951
  • 1.6279
  • 1.4555
  • 1.0078 *
  • 1. 6280...*.1. 3842.*.1. 6414
  • 1 3543..*.1. 3962.*. 1. 2797
  • 1. 4168.* 2. 0172.*.

11

  • 1.5262
  • 1.3741 *-1.5358
  • 1.3687
  • 1.6268
  • 1.481;
  • 1.6140 *-.9007 *

......**........ 2809..*.

. 1. 3560

  • 1. 5194
  • 1. 3593
  • 1. 5320
  • 1. 2831
  • 1. 408tS*

1.2833

  • 2 12
  • 1.3848
  • 1.6215
  • 1.4930
  • 1.A247
  • 1.4694
  • 1.6250
  • 1.2509 *

.......... 1. 2004..*. 1. 3971..*. 1. 2849..*. 1. 4184

  • 1. 2793..*.1. 6587 *
  • 1.4882
  • 13
  • 1.5690
  • 1.5272
  • 1.6258
  • 1.4791
  • 1.6268
  • 1.2049 *.8439 *
  • 1 3065
  • 1. 3521.*. 1. 2812
  • 1.4099
  • 1. 2793
  • 1.7232
  • 2,4404.*.

14

  • 1.3259
  • 1.6001
  • 1.4533
  • 1.6129
  • 1.2499
  • 8439 *
  • 1. 5330
  • 1.2766
  • 1. 4178.*.1. 2848
  • 1. 6600..*. 2 4431
  • 15
  • 1.2616 *.9971
  • 1.0067 *. 8 9 8 6
  • F SUB-Q
  • '1. 5935
  • 2.0228 + 2. 0196
  • 2. 2835
  • M-SUB-Q f

h AT 100% POWER, 4 EPPD, THIS IS LEVEL 11 0F 18 (LEVEL 18 = TOP OF 20RE, LEVEL 1 : BOTTOM)

H G

F E

D C

B A

8

  • 1.1481
  • 1.4973
  • 1.2916
  • 1.5358
  • 1.3912
  • 1.5707
  • 1.3313
  • 1.2638 *
  • 1. 9276.*. 1. 4711...*.1 7062.*. 1 4237... 1. 5692..*.1. 3745..*. 1. 6198
  • 1. 6828
  • 9
  • 1.4973
  • 1.3441
  • 1.5208
  • 1.3859
  • 1.6365
  • 1.5369
  • 1.6140 *.9992 *
  • 1.4711..*. 1.6426..*.1. 4430
  • 1 5877
  • 1. 3365..*.1. 4200
  • 1. 3378
  • 2. 1358..*

10

  • 1.2916
  • 1.5144
  • 1.2777
  • 1.5540
  • 1.5048
  • 1.6440
  • 1.4641
  • 1.0089 *
  • 1.7062..*. 1.4496
  • 1 7234
  • 1. 4159
  • 1. 4599..*.1. 3348.*.1 4833..*.2*.1270
  • 11
  • 1.5350
  • 1.3805
  • 1.5476
  • 1.3773
  • 1.6429
  • 1.4930
  • 1.6290 *.9018 *
  • 1. 4237
  • 1. 5945..*. 1.4214
  • 1.6026
  • 1. 3364..*.1. 4715
  • 1. 3354.*.2. 3915..*

12

  • 1.3912
  • 1.6343
  • 1.5015
  • 1.6408
  • 1.4812
  • 1.6429
  • 1.2563 *
  • 1. 5692..*.1.3381..*.1 4608
  • 1. 3380
  • 1 4869
  • 1. 3368.*.1 7418
  • 13
  • 1.5787
  • 1,5358
  • 1.6418
  • 1.4908
  • 1.6440
  • 1.2102 *.8450 *
  • 1. 3745
  • 1.4217.*.1. 3372..*. 1. 4724
  • 1.3363
  • 1 8099
  • 2 5705
  • 14
  • 1.3313
  • 1.6119
  • 1.4619
  • 1.6279
  • 1.2552 *.8439 *
  • 1 6198
  • 1. 3396
  • 1. 4853
  • 1 3362
  • 1.7433
  • 2.5735..*.

15

  • 1.2638 *

.9971

  • 1.0078 *

.8996

...................... 290..*.2.3966

  • M-SUB-Q
  • 1.6828
  • 2.1420
  • 2.1 3

APPENDIX Page 87 of 140 McGuire 2 Cylce 10 Core Operating Limits Report liable 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin)- Power Escalation AT 100% POWER, 4 EFPD, THIS IG LEVEL 10 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F A

...............................E........D.........C........B 8

  • 1.1610
  • 1.5315
  • 1.3120
  • 1.5722
  • 1.4169
  • 1.6183
  • 1.3548
  • 1.2916
  • 161....... 7655
  • 1. 4736
  • 1. 6337 *...... 1 4291.*.1.6935
  • 1 7490 *
  • 1.9950
  • 1.5
  • 1 9
  • 1.5315
  • 1.3655
  • 1.5572
  • 1.4148
  • 1.6804
  • 1.5712
  • 1.6590
  • 1.0153
  • 1.5161
  • 1.6964
  • 1.4895 *
  • 2.2347 *

............................ 1.6386

  • 1. 3824
  • 1.4766
  • 1. 3851 10
  • 1.3120
  • 1.5508
  • 1.2981
  • 1.5936
  • 1.5390
  • 1.6900
  • 1.4994
  • 1.0271 *

...................... 840

  • 1.4590
  • 1.5109
  • 1.3752
  • 1.5375
  • 2.2124 *
  • 1.7655
  • 1.4966
  • 1.7..................................................

11

  • 1.5722
  • 1.4094
  • 1.5862
  • 1.4052
  • 1.6900
  • 1.5294
  • 1.6783 *

.9168 *

.............................. 6545

  • 1. 3760...*.1. 5212
  • 1. 3715
  • 2 4803
  • 1.4736
  • 1.6459
  • 1.4658
  • 1 12
  • 1.4169
  • 1.6783
  • 1.5358
  • 1.6868
  • 1.5176
  • 1.6900
  • 1.2841 *

...................... 129.*.1. 3778

  • 1.5360
  • 1 3735
  • 1.7960 *
  • 1.6337
  • 1.3832
  • 1.5 1.2349 *

.8579

  • 13
  • 1.6193
  • 1.5701
  • 1.6879
  • 1.5272
  • 1.6911

.............................................. 1.8738

  • 2.6627 *
  • 1.4291
  • 1.4776
  • 1.3770
  • 1.5232
  • 1.3726 *

.8579

  • 14
  • 1.3548
  • 1.6558
  • 1.4973
  • 1.3761
  • 1.2831

..................................... 1.7974

  • 2.6656 *
  • 1.6935
  • 1.3871
  • 1.5389
  • 1.3724
  • 15
  • 1.2916
  • 1.0132
  • 1.0260 *

.9146

..................... 2146

  • 2.4911* 2...............* M-SUB-Q
  • 1.7490
  • 2.2399 AT 100% POWER, 4 EFPD, THIS IS LEVEL 9 0F 18 (LEVEL 18 TOP OF CORE, LEVEL 1 = BOTTCM)

H G

F C

B A

...............................E........D 8

  • 1.1406
  • 1.5069
  • 1.2906
  • 1.5519
  • 1.3977
  • 1.5990
  • 1.3345
  • 1.2691 *

..................... 7501..*. 1. 4581..*.1.6182

  • 1 4160
  • 1.6886
  • 1.7726.*

1.9807

  • 1.5027 *1 9
  • 1.5069
  • 1.3441
  • 1.5347
  • 1.3934
  • 1.6611
  • 1.5487
  • 1.6386 *

.9971 *

  • 1.5027
  • 1 6822
  • 1.4756
  • 1. 6241
  • 1.3661 + 1. 4629
  • 1. 3824
  • 2 2532
  • 10
  • 1.2906
  • 1.5283
  • 1.2777
  • 1.5733
  • 1.5187
  • 1.6729
  • 1.4791
  • 1.0089 *

.....................................................**..... 8

  • 2.2327
  • 1.7501
  • 1.4815
  • 1.7683
  • 1.4428
  • 1.4955
  • 1.3603
  • 1.530 11
  • 1.5519
  • 1.3880
  • 1.5658
  • 1.3869
  • 1.6718
  • 1.'5101
  • 1.6600 *

.9018 *

....................................... 3619

  • 1.5068
  • 1.3721
  • 2.5061.*

1.6313

  • 1.4504
  • 1.6373
  • 1.

1.4581 1.4983

  • 1.6729
  • 1.2649
  • 1.6590
  • 1.5155
  • 1.6697
  • 12
  • 1.3977
  • 1.6182
  • 1.3678
  • 1 4976
  • 1.3636
  • 1 5202
  • 1.3645
  • 1.7971
  • 1.5000
  • 1.6740
  • 1.2177 *.8429
  • 13
  • 1.5990
  • 1.5476
  • 1. b 9-

.......................... 6956

  • 1.3645
  • 1.8716
  • 2
  • 1.4160
  • 1.4639
  • 1.3628
  • 1. 5078
  • 14
  • 1.3345
  • 1.6354
  • 1.4769
  • 1.6579
  • 1.2638 *

.8416 *

..................................... 1 7985

  • 2.6956 *
  • 1.6886
  • 1.3841
  • 1.5329
  • 1.3738
  • 15
  • 1.2691 *

.9950

  • 1.0078 *

.8996

  • 1.7726
  • 2.2601
  • 2.2350
  • 2.5090
  • M-SUB-Q l

l APPENDIX Page 88 of 140 McGuire 2 Cylce 10 Core Operating Limits Report l'able 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 100% POWER, 4 EFPD, THIS IS LEVEL 8 OF 18 (LEVEL 18 = TOP OF COP.E. LEVEL 1 BOTTOM)

H G

I E

D C

B A

..................................................e............**.....***

1.3055

  • 1.5797
  • 1.4148
  • 1.6279
  • 1.3516
  • 1.2927
  • 8
  • 1.1481
  • 1.5337 3
  • 1.3972
  • 1.5599
  • 1.3561
  • 1.6289
  • 1.6915 *

.... 171

  • 1.4391
  • 1.687.......................................*....e*******...............
  • 1.9 9
  • 1.5337
  • 1.3602
  • 1.5637
  • 1,4148
  • 1.6943
  • 1.5733
  • 1.6729
  • 1.0078 *

........ 10

  • 1.3048
  • 1.4034
  • 1 3204.*.2.1674
  • 1.56

.... 391.*. 1.6205.*.1. 4124 *

  • 1.4 10 ' 1.3055
  • 1.5562
  • 1.2927
  • 1.6033
  • 1.5433
  • 1.7093
  • 1.5058
  • 1.0228
  • 1.6873
  • 1.4 1.7056 1.3789
  • 1.4335
  • 1.2957
  • 1.4668
  • 2.1461 *

............. 168 *.............'.....................................*. **...

.9125

  • 1.5797
  • 1.4084
  • 1.5958
  • 1.4062
  • 1.7082
  • 1.5369
  • 1.6997 11
  • 1.3972
  • 1.5677 1.3867
  • 1.5721
  • 1.2964
  • 1*
    • .................'........................... 1. 4400.*.1.3033.*. 2.413 12
  • 1.4148
  • 1.6933
  • 1.5401
  • 1.7050
  • 1.5251
  • 1.7104
  • 1.2863 *
  • 1.5599
  • 1.3064
  • 1.4363
  • 1.2987
  • 1.4523
  • 1.2964
  • 1.7188
  • 1.5347
  • 1.7115
  • 1.2359 *.8514
  • 13
  • 1.6279
  • 1.5722
  • 1.7061
  • 1 3561
  • 1. 4C52
  • 1.2900
  • 1.4419
  • 1.2957
  • 1.7913.*. 2.5883.*.

1.6986

  • 1.2852
  • 8514
  • 14
  • 1.3516
  • 1.6697
  • 1.5037 *
  • 1.6209
  • 1.3270
  • 1.4687 1.3041
  • 1.7202
  • 2.5913
  • 15
  • 1.2927
  • 1.0057
  • 1.0217 *

.9104 ' F-SUB-Q

  • 1.6915
  • 2.1738
  • 2.1482
  • 2.4158
  • M-sua-Q AT 100% POWER, 4 EFPD, THIS IS LEVEL 7 0F 10 (LEVEL 18 = TOP CF CORE, LEVEL 1 BOTTOM)

H G

F E

D C

B A

8

  • 1.1353
  • 1.5272 ' 1.2959
  • 1.5722
  • 1.4041
  • 1.6194
  • 1.3398
  • 1.2831 *

{

  • 1.8680
  • 1.3877
  • 1.6290
  • 1.3448
  • 1.5049
  • 1.3059
  • 1.5669
  • 1.6234
  • j 9
  • 1.5272
  • 1.3505
  • 1.5572
  • 1.4052
  • 1.6890
  • 1.5626
  • 1.6665 *

.9971

  • 1.

7 2692

  • 2.0895
  • l

................ 3596

  • 1.5099
  • 1.2589
  • 1 35 1..*.

1

.... 877

  • 1.5666 *
  • 1.3 1.2820
  • 1.5969
  • 1.5337
  • 1.7040
  • 1.4962
  • 1.0132
  • 10
  • 1.2959
  • 1.5487 l
  • 1.6290 '. 1.3663
  • 1.6472.*. 1. 3349
  • 1.3910
  • 1.2572..*.1 4152
  • 2 0621
  • 11
  • 1.5722 ' 1.3987
  • 1.5883
  • 1.3966
  • 1.7040
  • 1.5283 ' 1 6954 *

.9029 *

  • 1.3448
  • 1.5161
  • 1 3406
  • 1.5304
  • 1.2586
  • 1.4023
  • 1 2616.*. 2.3264
  • f 12 ' 1.4041 ' 1.6868
  • 1.5305
  • 1.6997 ' 1.5165
  • 1.7061
  • 1.2777
  • 1.3928
  • 1.2600
  • 1.4279
  • 1.2691
  • 1.6741 *
  • 1.5049 '. 1.2603 13 ' 1.6194
  • 1.5615
  • 1.7007
  • 1.5262
  • 1.7072
  • 1.2252 *

.8418 *

....................................................... 2 5218 *

  • 1.3059
  • 1.3507
  • 1.2594
  • 1.4041
  • 1.2684
  • 1.7616
  • 14
  • 1.3398
  • 1.6633
  • 1.4940
  • 1.6933
  • 1.2756 '

.6418 *

............... 1.2630

  • 1 6754 '.2.5247
  • 1.4180 *
  • 1 5669
  • 1. 2707

.9939

  • 1.0110 *

.9007

  • 1.2831 1.6234
  • 2.0935
  • 2.0659
  • 2.3288
  • M-SUB-Q

I 1

l APPENDIX l

Page 89 of 140 McGuire 2 Cylce 10 Core Operating Limits Report liable 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 100% POWER, 4 EFPD, THIS IS LEVEL 6 OF 18 (LEVEL 18 = TOP OF CCRE, LEVEL 1 = BOTTOM)

A

... 11.......................*...E........D.........C.........B G

F 8

  • 1.1085
  • 1.4930
  • 1.2659
  • 1.5369
  • 1.3709
  • 1.5797
  • 1.3055
  • 1.2456
  • 7 1 5968 *

.............................................. 1 2762.*.1 534..*..

  • 1.8149
  • 1.3518
  • 1.5085
  • 1.3133
  • 1.4693 *...........

.9671

  • 9
  • 1.4930
  • 1.3205
  • 1.5219
  • 1.3709
  • 1.6493
  • 1.5230
  • 1.6236 *

................... 2287......1. 3274.*. 1. 2419

  • 2.0546 *
  • 1.4751
  • 1

................... 1.3267 1.3510

  • 1.5260
  • 10
  • 1.2659
  • 1.5133
  • 1.2520
  • 1.5594
  • 1.4962
  • 1.6643
  • 1.4576 *

.9821 *

... 5805

  • 1. 3331
  • 1. 6000 *....... 1 3023.*. 1.3502..*. 1 2244..*.1. 3847
  • 2 0299..*
  • 1.

11

  • 1.5369
  • 1.3645
  • 1.5500
  • 1.3645
  • 1.6633
  • 1.4898
  • 1.6515 *

.B750 *

... 3133

  • 1 4810.*.1. 3078..*. 1.4898
  • 1. 2251..*.1.3673.+. 1. 2312
  • 2. 2853.*.
  • 1.

12

  • 1.3709
  • 1.6472
  • 1.4930
  • 1.6600
  • 1.4791
  • 1.6643
  • 1.2402 *
  • 1. 4693
  • 1. 2300..*. 1 3599
  • 1 2278
  • 1 3868
  • 1.2317
  • 1.6371
  • j 13
  • 1.5797
  • 1.5200
  • 1.6611
  • 1.4876
  • 1.6643
  • 1.1910 *.8150
  • l'

................... 1 2265

  • 1. 3602.*. 1.2310.*. 1 7145.*. 2.4737
  • 1.2762
  • 1.3290
  • 14
  • 1.3055
  • 1.6215
  • 1.4555
  • 1.6504
  • 1.2391 *

.8150 *

................... 1 3865

  • 1. 2320
  • 1. 6.386.*.2.4738.*.

1.2433

  • 1.5347 15
  • 1.2456 *

.9650 *

.9810 *

.8739

  • 2.2899
  • M-SUB-Q
  • 1.5968
  • 2.0603.*.2.0319 AT 100% POWER, 4 EFPD, THIS IS LEVEL 5 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTCM)

H G

F E

D C

B A

8* 1.1074

  • 1.5048
  • 1.2691
  • 1.5455
  • 1.3720
  • 1.5951
  • 1.3002
  • 1.2456 *

..................... 5071..*. 1. 2438..*.1.3907

  • 1. 2106
  • 1. 4690
  • 1. 5253.*.

1.7258

  • 1.2752
  • 1...

1.3240

  • 1.5337
  • 1.3730
  • 1.6547
  • 1.5219
  • 1.6279 *

.9607

  • 9
  • 1.5048 *
  • 1..,2752
  • 1. 4453
  • 1 2536
  • 1 4014
  • 1.1655
  • 1.2643
  • 1.1797
  • 1.9772
  • 10
  • 1.2691
  • 1.5251
  • 1.2541
  • 1.5647
  • 1.4940
  • 1.6686
  • 1.4555 *

.9768 *

....... 2341..*. 1 2923

  • 1. 1600
  • 1.3205
  • 1.9478..*.
  • 1

...................... 287

  • 1.5071
  • 1.2599
  • 1.5 1.5455
  • 1.3666
  • 1.5551
  • 1.3623
  • 1.6675
  • 1.4876
  • 1.6550 *

.8686

  • 11

............... 1. 1612

  • 1.3005..*. 1.1678
  • 2. 1981
  • 1.4175 *

................... 1. 2396 *

  • 1.2438
  • 1.4077
  • 12
  • 1.3720
  • 1.6526
  • 1.4900
  • 1.6643
  • 1.4769
  • 1.6675
  • 1.2349 *
  • 1.3987
  • 1.1667
  • 1.2938
  • 1.1636 '. 1. 3143
  • 1.1655
  • 1 5629
  • 1.5197
  • 1.6654
  • 1.4855
  • 1.6606
  • 1.1835 *

.8075

  • 13
  • 1.5851
  • 1.2106
  • 1.2657
  • 1 1624
  • 1 3020
  • 1.1648
  • 1. 6367
  • 2.3768
  • l I

1.4533

  • 1.6536
  • 1.2338 *

.8065

  • I 14
  • 1.3002
  • 1.6250 *
  • 1 4690
  • 1.1815
  • 1.3222
  • 1.1690.*. 1.5640
  • 2. 3793
  • l 15
  • 1.2456 *

.9575 *

.9757 *

.8664

  • 1.5253
  • 1.9809
  • 1.9495
  • 2.2005
  • M-sun-Q l

l i

w..

APPENDIX Page 90 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report 1 Fable 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 100% POWER, 4 EFPD, THIS IS LEVEL 4 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 s BOTTOM)

H G

D C

B A

......................F.........E..........................................

8

  • 1.0742
  • 1.4576
  • 1.2316
  • 1.4919
  • 1.3259
  • 1.5240
  • 1.24f4
  • 1.1824
  • 1.6985 1.2576
  • 1.4832
  • 1.2305
  • 1
  • 1.5362 *

.........'.............................. 3818

  • 1. 2020.*. 1.46Lt
  • 1.5551 *

.9146

  • 9* 1.4576
  • 1.2852
  • 1.4833
  • 1.3238
  • 1.5872
  • 1.4587 1.2576
  • 1.4217
  • 3
  • 1.2584
  • 1.1795
  • 1.9861 *

................... 1. 2367

  • 1 3870.*. 1 159 10
  • 1.2316
  • 1.4758
  • 1.2145
  • 1.5048
  • 1.4319
  • 1.5969
  • 1.3902 *.9286
  • 1.9599 *
  • 1.4832.*. 1.2436
  • 1.5064
  • 1 2223
  • 1. 2846
  • 1.1551..*. 1. 3195
  • 11
  • 1.4919
  • 1.3173
  • 1.4973
  • 1.3120
  • 1.5958
  • 1.4223
  • 1.5744 *

.8236 *

............................................................ 1

  • 2.2113
  • 1.170
  • 1.2305
  • 1.3932
  • 1.2278
  • 1.4019
  • 1.1557
  • 1.2957 1.3259
  • 1.5851
  • 1.4287
  • 1.5926
  • 1.4116
  • 1.5904
  • 1.1727
  • 12 *
  • 1 3818..*. 1.1605
  • 1 2860
  • 1.1581
  • 1.3064
  • 1.1623 '. 1.5676
  • 13 ' 1.5240
  • 1.4566
  • 1.5936
  • 1.4201
  • 1.5904
  • 1.1256
  • 7647 *
  • 1.2020
  • 1.2598
  • 1.1575.*. 1.2972 + 1 1617 '. 1.6370
  • 2.3920
  • 14
  • 1.2456 ' 1.5530
  • 1.3869
  • 1.5722
  • 1.1717
  • 7636 *
  • 1.4655
  • 1.1814
  • 1.3218
  • 1.1708 '. 1.5699
  • 2.3942 *

.9125 *

.9275 *

.8225

  • 1.1824
  • 1.5362 '.1.9915..*.1. 9616
  • 2.2158
  • M-SUB-Q AT 100% FOWER, 4 EFFD, THIS IS LEVEL 3 OF 10 (LEVEL 18 s TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8

  • 1.0571 ' 1.4341
  • 1.2167
  • 1.4641
  • 1.3013
  • 1.4812
  • 1.1963
  • 1.1235 *

................................................ 1918

  • 1.4703
  • 1.5609 *
  • 1.6640
  • 1.2314
  • 1.4485
  • 1.2006
  • 1.3567
  • 1.

i 9

  • 1.4341
  • 1.2659
  • 1.4630
  • 1.3023
  • 1.5380
  • 1.4105
  • 1.4919 *

.8729 *

  • 1.2314
  • 1.3915 '.1.2086 '. 1.3584
  • 1.1523..*. 1. 2536
  • 1.1853
  • 2.0009
  • f 10
  • 1.2167
  • 1.4555
  • 1.1995 ' 1.4726
  • 1.3800
  • 1.5390
  • 1.3323 *

.8836 *

  • 1 4485..*.1.2151..*.1.4704.*.1. 2021
  • 1 2751..*.1.1523..*. 1.3258
  • 1 9857
  • 1.4662
  • 1.2809
  • 1.5390 ' 1.3687
  • 1.4973 *

.7797 *

  • 1.2959
  • 11
  • 1.4641
  • 1.2006.'.1.3650 '. 1.2079
  • 1 3811.*. 1.1534.*. 1.2950
  • 1.1834
  • 2 2551
  • 12
  • 1.3013 ' 1.5358
  • 1.3869
  • 1.5358
  • 1.3602
  • 1.5230
  • 1.1138
  • I 1.1540
  • 1.2765
  • 1.1553
  • 1.3041 + 1.1661
  • 1.5876 *
  • 1. 3567...................

13

  • 1.4812
  • 1.4094 ' 1.5350
  • 1.3666
  • 1.5240
  • 1.0710 *

.7229

  • 2.4351 *
  • 1.1918
  • 1.2549
  • 1 1535
  • 1.2973
  • 1.1655
  • 1. 6537 14
  • 1.1963
  • 1.4087
  • 1.3302
  • 1.4951 ' 1.1128 '

.7229 *

.......... 1.1872

  • 1.3274
  • 1 1846 '. 1.5889 '.2.4355 *
  • 1.4703 *

.8825 *

.7775

  • 1.1235 *

.8707

  • 1.5609
  • 2.0144
  • 1.9892
  • 2.2576
  • M-SUB-Q

APPENDIX Page 91 of 140 McGuire 2 Cylce 10 Core Operating Limits Report l'able 2 (cont.)

F-sub-QfM sub-Q Values (F-sub-Q OP Margin)- Power Escalation AT 100% FCWER.

4 EFPD, THIS IS LEVEL 2 OF 18 (LEVEL 18 = TCP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.9842

  • 1.3184
  • 1.1299
  • 1.3495
  • 1.2070
  • 1.3205
  • 1.0571 *.9543 *
  • 1. 7 413
  • 1 3 0 4 0
  • 1 518 3. *.1. 2 7 71.. +.1.

4 2 5 0. *. 1. 3 016

  • 1. 62 0 0. *. 1. 7 90 0. *.

9

  • 1.1184
  • 1.1663
  • 1.3559
  • 1.2177
  • 1.3816
  • 1.2638
  • 1.3066 *

.7668 *

  • 1 3040
  • 1.4711..*.1 2698
  • 1. 4132..*. 1. 2491..*. 1. 3612.*. 1. 3162 + 2.2289.*.

10

  • 1.1299
  • 1.3495
  • 1.1235
  • 1.3484
  • 1.2Tr'
  • 1.3741
  • 1.1717 *

.7647 *

...**......... 1. 4670

  • 2.2377 *
  • 1.2546 *
  • 1. 5183
  • 1 2763
  • 1. 5287
  • 1. 2778.*. 1.3..,

1.3420

  • 1.1813
  • 1.3784
  • 1.2209
  • 1.2788 *

.6694

  • 11
  • 1.3495
  • 1.2124

.......... 36.*.1 4567

  • 1.2539
  • 1 4113.*. 1. 3471.*. 2.5566
  • 1.28

............ 4196 *

  • 1.2771
  • 1.

12

  • 1.2070
  • 1.3794
  • 1.2552
  • 1.3741
  • 1.2177
  • 1.3302 *.9639
  • 1.4250
  • 1.2512
  • 1.2568
  • 1.4149
  • 1.2971
  • 1.7856 *

................... 1. 3706

  • 13
  • 1.3205
  • 1.2627
  • 1.3720
  • 1.2188
  • 1.3313 *

.9403 *

.6255 *

................................ 31* 1.41..*.1.2963

  • 1..,8313
  • 2. 7387
  • 1.3016
  • 1.3622
  • 1.2561 1.0571
  • 1.3045
  • 1.1695
  • 1.2777 *

.9628 *

.6255

  • 14 *

................... 1 4698

  • 1. 3487
  • 1. 7871.*.2.7421.*

1.6208

  • 1.3184
  • 15 *

.9543

  • 7647 *

.7636 *

.6683

........ 621.*. M-sUB-Q

  • 2.5

. 1. 7900

  • 2.2354
  • 2 2399 AT 100% PCWER, 4 EFPD, THIS IS LEVEL 1 CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 : BOTTCM)

H C

F E

D C

B A

8*

7154 *

.9425

  • 7743 *

.9928 *

.8407 *

.8557 *

.7036 *

.5741

  • 2.1776
  • 1.7018
  • 2.0105
  • 1.9711
  • 2.3949
  • 2.9297 2.3573
  • 1.7907
  • 9*

.9425

  • 7850 *

.9693 *

.8707

  • 1.0014 *.8182 *.8579 *.5044 *

.,....................................................... 9674

  • 3.3289 *
  • 1.7907
  • 2.1501
  • 1.7431
  • 1.9404
  • 1.6888
  • 2.0662
  • 1................

10 *

.7743 *

.9660 *

.7904 *

.9885 *

.8472 *.9703 *

.7433 *.4841

  • l i
  • 2. 17 7 6
  • 1 7 4 8 4
  • 2.137 9
  • 1.710 8
  • 1. 99 42 + 1.7 415
  • 2.27 01..*. 3. 4 68 6
  • 11 *

.9928 *

.8675 *

.9832 *

.8075 *

.9778 *

.8000 *

.7968 *

.4252 *

  • 1.7010
  • 1.9490
  • 1.7202
  • 2.0936
  • 1.7300
  • 2.1134
  • 2.1192
  • 3.9559
  • l 12 *

.8407 *

.9982 *

.8450 *

.9735 *

.6054 *

.8697 *

.6094 *

  • 2.0105
  • 1.6938
  • 2.0014
  • 1. 7374.*. 2.1013 *.......... 9468
  • 2.7700..*.

1 13 *

.8557 *

.8172 *.9693 *

.7990 *

.8697 *.6100 *.4016 *

  • 1.9711
  • 2.0681
  • 1.7442
  • 2.1171.*.1.9453
  • 2.7328
  • 4.1931
  • 14 *

.7036 *

.8568 *

.7422 *

.7958 *

.6083 *

.4016 *

  • 2.3949
  • 1.9693
  • 2.2728
  • 2.1212
  • 2.7735
  • 4.1931
  • 15 *

.5741 *

.5034 *

.4841 *

.4241

  • 3.4741
  • 3.9620
  • M-SUB-Q

. 2.9297

APPENDIX l

Page 92 of 140

(

McGuire 2 Cylce 10 Core Operating Limits Report l'able 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 75% POWER, 4 EFFD, THIS IS LEVEL 18 OF 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 = BOTTOM)

....H.........G..................E.........D........C.........B.........A F

.6062

  • 8*

.6276 *

.8750 *

.7958 *

.9789 *

.8675 *

.8632 *

.7497 *

..........'......... 2 2200

  • 1.7916
  • 2.0149
  • 2. 0134
  • 2. 3109
  • 2.8227
  • 2.5449 2.0638
  • 9*

.8750 *

.7690 *

.9436 *.8606 *

.9746 *

.8215 *

.8482 *.5526 *

.............. 40 *.... 1 8754

  • 2.0194
  • 1.7983..*. 2. 1216
  • 2. 0430
  • 3.1001
  • 2.0638
  • 2.32

.9446 *

.8257 *.9160 *

.7454 *

.5141

  • 10 *

.7958 *

.9436 *

.8097

  • 3.3585 *
  • 2.2200
  • 1.8767
  • 2.1880
  • 1.8754 *
  • 2.3474

..................................... 2. 1455

  • 1.9271 11 *

.9789 *

.8686 *

.9414 *

.7797 *

.8547 *

.7272 *

.7326 *

.4402 *

  • ..................................'.................... 4503 *........ 9970 *
  • 1.7916
  • 2.0215
  • 1.8815
  • 2.2885 2.0601
  • 2.4494
  • 2 3.

12 *

.8675 *

.9746 *

.8236 *

.8525 *

.6115 *

.6651.*

.5500 *

  • 2.0149
  • 1.7975
  • 2.1490
  • 2.0648
  • 2.4020
  • 2.2750 3.0014
  • 13 *

.8632 *

.8215 *

.9157 *

.7261 *

.6651 *

.4766 *

.3604 *

  • 2.0134
  • 2.1226 '.1.9285
  • 2.4516
  • 2.2750
  • 2 9969
  • 4.3943 *

.8472 *

.7454 *

.7315 *

.5569 *

.3684

  • 7497 14 *
  • 2.3109
  • 2.0461
  • 2.3507
  • 2. 4526
  • 3.0816
  • 4.3943
  • 15 *

.6062 *

.5516 *

.5130 *

.4391

.............. 50

  • 3.3652
  • 4.0029
  • M-SUB-Q
  • 2.8227
  • 3.10 AT 75% POWER, 4 EFPD, THIS IS LEVEL 17 0F 18 (LEVEL 10 s TOP OF CORE. LEVEL 1 : BOTTOM)

...............................E.......D..................B........A H

G F

C 8*

.8664

  • 1.1802
  • 1.0935
  • 1.2509
  • 1.1899
  • 1.2649
  • 1.0006 *

.9510 *

.'.........'.1 6231..*.1.7148

  • 1.4676
  • 1. 5381
  • 1 4355.*. 1.6689..'.1.8786
  • 1.9797 9
  • 3.1802
  • 1.0913 ' 1.2445
  • 1.1588
  • 1.2638
  • 1.2316
  • 1.2242 *

.8043 '

...... 1

  • 1.7436
  • 1 4935
  • 1. 5874
  • 1 4441..*. 1. 4000
  • 1. 4875..*.2. 2260..*.

1.623 10

  • 1.0935
  • 1.2402
  • 1.0967 ' 1.2284
  • 1.1813
  • 1.2466
  • 1.1117 *

.7743

  • 4.....

1 6981..*.1 5131

  • 1. 5766
  • 1. 4849
  • 1. 6566
  • 2. 3376..*
  • 1.7149 a 1.4981
  • 11
  • 1.2509
  • 1.1578
  • 1.2252
  • 1.0881
  • 1.1717
  • 1.0849
  • 1.1181
  • 6715 *
  • 1.4676
  • 1.5C92.*. 1. 5170
  • 1. 7405
  • 1. 6260
  • 1.7407
  • 1.6948
  • 2.7503
  • 12
  • 1.1899
  • 1.2649
  • 1.1802
  • 1.1706 *.8943
  • 1.0153 *

.8654

  • 1..*. 1.4421.'.1.5775
  • 1. 6279
  • 1.7226
  • 1.6369 '.2.1213 *
  • 1.538 13
  • 1.2649
  • 1.2306
  • 1.2466
  • 1.0849
  • 1.0153 *

.7551 *

.5730 *

..................... 4861.*.1.7429

  • 1.6359
  • 2 1266
  • 3.0539
  • 1.4355
  • 1.4800
  • 1........................

14

  • 1.0806
  • 1.2220
  • 1.1106
  • 1.1171 *

.8643 *

.5719 *

..................'.1 6586

  • 1.6969
  • 2.1214
  • 3.0539 *
  • 1.6609
  • 1.4896 15 *

.9510 *

.8022 *

.7733 *

.6694 ' F-SUB-Q

.............. 14 2.3400

  • 2.7540
  • M+SUB-Q 1.8786
  • 2.23 l

e l

i

APPENDIX Page 93 of140 McGuire 2 Cylce 10 Core Operating Limits Report j

l'able 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 75% POWER, 4 EFPD, THIS IS LEVEL 16 OF Id (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H C

F E

D A

.................................................C.........B...............

8

  • 1.0303
  • 1.3612
  • 1.2199
  • 1.4126
  • 1.3152
  • 1.4555
  • 1.2381
  • 1.1342 *
  • 1.9047 *

.......... 1.5213

  • 1.6599
  • 1.3687
  • 1.4579
  • 1.3097............................................

1 5302

  • 1.6558
  • 9
  • 1.3612
  • 1.2370
  • 1.4019
  • 1.2788
  • 1.4576
  • 1.4137
  • 1.4416 *.9253 *
  • 1.5213
  • 1.6660
  • 1.4064
  • 1.5193
  • 1.3147
  • 1.3538
  • 1.3271
  • 2.0342
  • 10
  • 1.2199
  • 1.3966
  • 1.2059
  • 1.3966
  • 1.3527
  • 1.4501 t_
  • 1.3045 *

.9093 *

  • 1.6599
  • 1.4114
  • 1.6415
  • 1.

.............................. 4099

  • 1 4574
  • 1.3481 *

.............** 1.4873

  • 2.0940
  • 11
  • 1.4126
  • 1.2756
  • 1.3923
  • 1.2263
  • 1.3987
  • 1.2873
  • 1.3709 *

.7968 *

  • 1.3687
  • 1

............ 5209

  • 1.4139
  • 1.6698..*.1.4654
  • 1.5819
  • 1.4793
  • 2.4492
  • 12
  • 1.3152
  • 1.4598
  • 1.3516
  • 1.3966
  • 1.1867
  • 1.3120
  • 1.0592 *

..'............................ 4670

  • 1.5690.*.1.4544
  • 1.8809 *

.4579

  • 1.3128
  • 1.4587
  • 1.

13

  • 1.4555
  • 1.4137
  • 1.4491
  • 1.2863
  • 1.3120 *

.9735 *

.7047

  • 1.3097
  • 1.3540
  • 1.3494
  • 1.

.............................. 5828

  • 1.4537
  • 1.9159
  • 2.7350
  • 14
  • 1.2381
  • 1.4394
  • 1.3023
  • 1.3698
  • 1.0592 *

.7047 *

  • 1.5302
  • 1.3288
  • 1.4

...................... 889

  • 1.

..... 4808.*.1.89'.2

  • 2 7374................'

15

  • 1.1342 *

.9232 *

.9082 *

.7947

  • 1.6550
  • 2.03

.............. 97

  • 2.0967
  • 2.

............... 4535..* M-SUB-Q AT 75% POWER, 4 FFFD, THIS IS LEVEL 15 0F 18 (LEVEL 18 = TOP CF CORE, LEVEL 1 = BOTTOM)

H C

F D

C B

A

...............................E..........................................

B* 1.1449

  • 1.4748
  • 1.2927
  • 1.5123
  • 1.3902 1.5604
  • 1.3227
  • 1.2338 *
  • 1.9433
  • 1.5217
  • 1.6902
  • 1 3582
  • 1.4596 '.1.2920
  • 1.5148
  • 1.6069
  • 9
  • 1.4748
  • 1.3323
  • 1.5005
  • 1.3655
  • 1.5840
  • 1.5144
  • 1.5733 *.9917
  • 1.5217
  • 1.6853
  • 1.4036
  • 1.5
  • ................................292
  • 1.2912
  • 1.3369
  • 1.2860
  • 2.0091 10
  • 1.2927
  • 1.4951
  • 1.2713
  • 1.5000
  • 1.4651 1.5819
  • 1.4234
  • .9853 *
  • 1.6902
  • 1.4067
  • 1.6686 *

............................ 1.3931

  • 1.4356
  • 1.3131......................................

425 *

  • 1.4441
  • 2.0 11
  • 1.5123
  • 1.3612
  • 1.5026
  • 1.3291
  • 1.5562
  • 1.4255
  • 1.5350 *

.8697 *

  • 1.3582
  • 1.530

............... 1

  • 1.3977
  • 1.67

................ 29

  • 1.4253
  • 1.5466
  • 1.4150
  • 2.3787
  • 12 + 1.3902
  • 1.5829
  • 1.4641
  • 1.5540
  • 1.3912
  • 1.5251

+

1.1886 *

. 1.4596

  • 1.2895
  • 1.4370
  • 1.4275
  • 1.5381
  • 1.4074
  • 1.0291
  • 13
  • 1.5604
  • 1.5144
  • 1.5808
  • 1.4244
  • 1.5262
  • 1.1299 *

.7936

  • 1.2920
  • 1.3369
  • 1.314

........................ 2

  • 1.5503
  • 1.4067 *..................... 1.8727
  • 2.6838
  • 14
  • 1.3227
  • 1.5712
  • 1.4212
  • 1.5347
  • 1.1877 *

.7925

  • 1.5148
  • 1.2877 *1

..................... 4463

  • 1.4164
  • 1.8303
  • 2.6840
  • 15
  • 1.2338 *

.9885 *

.9842 *

.8606

  • 1.6069
  • 2.0144
  • 2.0455
  • 2.38

................................ 27

  • M-SUB-Q m..

APPENDIX Page 94 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 75% POWER, 4 EFFD, TEIS IS LEVEL 14 0F 18 (LEVEL 18 = TOP CF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8

  • 1.1620
  • 1.4983
  • 1.3034
  • 1.5347
  • 1.4041
  • 1.5829
  • 1.3398
  • 1.2541 *
  • 2. 0660
  • 1.6006
  • 1.0043.*. 1 4313
  • 1.5425
  • 1. 3572
  • 1.5877
  • 1.6759.*.

9

  • 1.4983
  • 1.3527
  • 1.5208
  • 1.3869
  • 1.6236
  • 1.5412
  • 1.6086
  • 1.0035 *
  • 1. 6006
  • 1.7845
  • 1.4844.*.1.6185.*.1 3545
  • 1 4054
  • 1.3396
  • 2. 1048.*.

10

  • 1.3034
  • 1.5144
  • 1.2841
  • 1.5390
  • 1.4994
  • 1.6226
  • 1.4576
  • 1.0025 *
  • 1.8043
  • 1.4903
  • 1.7736
  • 1.4658
  • 1 5100
  • 1 3743
  • 1.5131..*.2.1450
  • 11
  • 1.5347
  • 1.3827
  • 1.5337
  • 1.3655
  • 1.6129
  • 1.4748
  • 1.5947 *

.8921 *

  • 1.4313
  • 1 6212
  • 1. 4710 *...... 1.7492.*.1. 4749
  • 1.6082.*. 1.4720
  • 2 5017
  • 12
  • 1.4041
  • 1.6226
  • 1.4994
  • 1.6108
  • 1.4533
  • 1.6001
  • 1.2338 *
  • 1.5425
  • 1.3526
  • 1.5124
  • 1.4772
  • 1. 6061.*. 1.4610
  • 1.9034
  • 13
  • 1.5829
  • 1.5401 + 1.6215
  • 1.4737
  • 1.6001
  • 1.1845 *

.8257 *

  • 1.3572..*. 1.4061
  • 1 3756
  • 1.6100
  • 1.4600
  • 1.9581.*. 2.8113
  • 14
  • 1.3398
  • 1.6054
  • 1.4555
  • 1.5936
  • 1.2338 *

.8247 *

  • 1.5877
  • 1 3415
  • 1.5147
  • 1.4795
  • 1.9050
  • 2.8140
  • 15
  • 1.2541
  • 1.0003
  • 1.0014 *

.9900

  • 1.6759
  • 2.1100
  • 2.1481..*.2.5060
  • M-SUB-Q AT 75% POWER, 4 EFFD.

THIS IS LEVEL 13 0F 10

/EL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8

  • 1.1910
  • 1.5551
  • 1.3398
  • 1.5936
  • 1.4469
  • 1.6451
  • 1.3827
  • 1.3045 *
  • 2.1599
  • 1.6521
  • 1.,9124
  • 1.5007
  • 1. 6298
  • 1.4199
  • 1.6684
  • 1.7417
  • 9
  • 1.5551
  • 1.3934
  • 1.5787
  • 1.4384
  • 1.6975
  • 1.6033
  • 1.6804
  • 1.0346 *

............................................................... 2.2094

  • 1.6521
  • 1,8447
  • 1.5567
  • 1.7005
  • 1.4162
  • 1.4756
  • 1.3930
  • 10
  • 1.3390
  • 1.5722
  • 1.3216
  • 1.6033
  • 1.5626
  • 1.6997
  • 1.5208
  • 1.0410 *
  • 1.9124
  • 1.5632..*. 1.0762
  • 1.5350
  • 1.5862
  • 1. 4335..*. 1.5812
  • 2. 2448
  • 11
  • 1.5936
  • 1.4330
  • 1.5979
  • 1.4212
  • 1.6975
  • 1.5465
  • 1.6847 *

.9275

  • 1.6446
  • 1.4972
  • 2.6273 *

.......... 95

  • 1.5405
  • 1. 7995.*. 1.4987
  • 1.70
  • 1. 5007 12
  • 1.4469
  • 1.6965
  • 1.5615
  • 1.6954
  • 1.5294
  • 1.6922
  • 1.2970 *

..............................., 10

  • 1. 6621
  • 1 4901
  • 1.9492
  • 1.6298
  • 1.4143
  • 1.5800
  • 1.50 13
  • 1.6451
  • i.6022
  • 1.6965
  • 1.5444
  • 1.6933
  • 1.2456 *

.8643 *

  • 1.4199
  • 1.4763.*.1.4348
  • 1.6457.*. 1 4979
  • 2.0315
  • 2.9097
  • 14
  • 1.3827
  • 1.6783
  • 1.5187
  • 1.6836
  • 1.2959 *

.8632 *

  • 1.6684
  • 1.3950
  • 1.5838
  • 1.4987
  • 1.9515
  • 2.9126
  • 15
  • 1.3045
  • 1.0324
  • 1.0389 *

.9253

  • 1.7417
  • 2.2144
  • 2.2401 + 2.6341
  • M-SUB-Q

\\

.e...................e...............

APPENDIX Page 95 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 75% POWER, 4 EFPD, THIS IS LEVEL 12 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

......................F........E.......D.........C..................A H

0 B

8

  • 1.1867
  • 1.5572
  • 1.3377
  • 1.6001
  • 1.4400
  • 1.6526
  • 1.3837
  • 1.3077 *

........................................................... 18

  • 1 8935
  • 2.3245
  • 1.7600
  • 2.0532
  • 1.6362
  • 1.7825
  • 1.5409
  • 1.82 9
  • 1.5572
  • 1.3923
  • 1.5840
  • 1.4426
  • 1.7115
  • 1.6097
  • 1.6922
  • 1.0346 *

................................. 1 6126

  • 1.5143
  • 2.4120
  • 1.6986
  • 1.0672
  • 1.543*
  • 1 7688
  • 1. 9797 1.7179
  • 1.5294
  • 1.0421
  • 10
  • 1.3377
  • 1.5765
  • 1.3216
  • 1.6161
  • 1.5722 2.0532
  • 1.7054
  • 2.0550
  • 1.6721
  • 1.73 1.5594
  • 1.7228
  • 2.4497

......................................... 27

  • 1.6001
  • 1.4373
  • 1.6086
  • 1.4298
  • 1.7168
  • 1.5594
  • 1.7050 *

.9307

  • 11 *

................... 1 6787

  • 1.9188
  • 1 5908
  • 1 7490
  • 1 5876
  • 2. 8702
  • 1.6362
  • 1.8694 *
  • 1.3066
  • 12
  • 1.4400
  • 1.7093
  • 1.5690
  • 1.7136
  • 1.5444
  • 1.7157
  • 1.7825
  • 1.5407
  • 1.7347
  • 1.5934
  • 1.7632
  • 1.5848
  • 2.0722
  • 13
  • 1.6526
  • 1.6076
  • 1.7147
  • 1.5572
  • 1.7157
  • 1.2574 *

.8697 *

  • 1.5489
  • 1.6135
  • 1.5618
  • 1.7511
  • 1 5846
  • 2.1545
  • 3.0931
  • 14
  • 1.3837
  • 1.6890
  • 1.5272
  • 1.7040
  • 1.30d5 *

.8686 *

  • 1.8218
  • 1.5165
  • 1.7258
  • 1.5885
  • 2.0737
  • 3.0931
  • 15
  • 1.3077
  • 1.0314
  • 1.0410 *

.9286

  • 1.8935
  • 2. 4195
  • 2 4538
  • 2.R750
  • M-SUB-Q AT 75% POWER, 4 EFPD, THIS IS LEVEL 11 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H C

F E

D C

B A

8

  • 1.1685
  • 1.5390
  • 1.3205
  • 1.5851
  • 1.4330
  • 1.6365
  • 1.3677
  • 1.2917 *
  • 2.5198
  • 1.9039
  • 2.2189
  • 1.8093
  • 1.9784
  • 1.7166
  • 2.0204
  • 2.0948
  • 9
  • 1.5390
  • 1.3741
  • 1.5679
  • 1.4276
  • 1.6986
  • 1.5926
  • 1.6772
  • 1.0196 *
  • 1.9039
  • 2.1366
  • 1.8634
  • 2.0515
  • 1 7075
  • 1.7911
  • 1.6742
  • 2.6769
  • 10
  • 1.3205
  • 1.5604
  • 1.3066
  • 1.6054
  • 1.5583
  • 1.7082
  • 1.5155
  • 1.0292 *

........................ 2..*.1 8258

  • 1.8781..*. 1.7109
  • 1.9071
  • 2. 7161
  • 2.239
  • 2.2189
  • 1.9717 11
  • 1.5851
  • 1.4212
  • 1.5979
  • 1.4180
  • 1.7072
  • 1.5476
  • 1.6954 *

.9200 *

........................**............................. 1 7093

  • 3.1154
  • 1.8326
  • 2.0720
  • 1.7129
  • 1.8899 *
  • 1.8093
  • 2.0601 12
  • 1.4330
  • 1.6965
  • 1.5551
  • 1.7040
  • 1.5337 + 1.7072
  • 1.2948 *
  • 1.9784
  • 1.7055
  • 1.8793.*. 1 7159
  • 1.9104
  • 1.7132
  • 2.2486
  • 13
  • 1.6365
  • 1.5904
  • 1.7050
  • 1.5455
  • 1.7082
  • 1.2466 *

.8589

  • j 1.7139
  • 1.8914
  • 1.7122
  • 2.3368
  • 3.3562 *
  • 1.7166
  • 1.7911

)

14

  • 1.3677
  • 1.6750
  • 1.5123
  • 1.6933
  • 1.2938 *

.8589 *

  • 2
  • 1.6769
  • 1.9095
  • 1.7103
  • 2.7503
  • 3.3600 *

... 0204 1.0174

  • 1.0282 *

.9178

  • 1.2927
  • 2.0948
  • 2.6840
  • 2.7209
  • 3.1220
  • M-SUB-Q

/ "PENDIX Page 96 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 75% POWER, 4 EFFD, THIS IS LEVEL 10 OF 18 (LEVEL 18 2 TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B h

B

  • 1.1652
  • 1.5508
  • 1.3227
  • 1.5979
  • 1.4373
  • 1.6491
  • 1.3709
  • 1.3034
  • 2.3225
  • 1.9213
  • 2.1341
  • 1.8583
  • 2.2216
  • 2.2840 *
  • 2 6362.*. 1.9847..............................................................

9

  • 1.5508
  • 1.3773
  • 1.5808
  • 1.4351
  • 1.7147
  • 1.6011
  • 1.6943
  • 1.0217
  • 2.9379
  • 1.9847
  • 2.2327
  • 1.9441
  • 2.1419
  • 1.7916
  • 1.9188
  • 1.8114 1.5733
  • 1.3098
  • 1.6204
  • 1.5679
  • 1.7275
  • 1.5262
  • 1.0335
  • 10
  • 1.3227 *

.......................... 1 7840

  • 2.0131.*.2.9650
  • 1.9648 *
  • 2.3225
  • 1.9531.*.2.3465
  • 1.9014
  • 1.7169 *

.9221

  • 11
  • 1.5979
  • 1.4298
  • 1.6119
  • 1.4244
  • 1.7265
  • 1.5594 3.3340 *

.... 213

  • 2. 1513
  • 1.9113
  • 2.1639
  • 1.7862
  • 1 9780
  • 1. 7960 *
  • 1.9............................................................
  • 1.7136
  • 1.5647
  • 1.7232
  • 1.5455
  • 1.7286
  • 1.3045
  • 12
  • 1.4373
  • 2.1341
  • 1.7938
  • 1.9674 + 1.7894
  • 1.9995
  • 1.7894
  • 2.3691
  • 13
  • 1.6493
  • 1.5990
  • 1.7243
  • 1.5572
  • 1.7286
  • 1.2541 *

.8622 *

  • 1.8583
  • 1.9200
  • 1.7873
  • 1.9807
  • 1.7884
  • 2.4704
  • 3.585*
  • 14
  • 1,3709
  • 1.6911
  • 1.5240
  • 1.7157
  • 1.3023 *

.8611

  • 2.2216
  • 1.8137
  • 2.0159
  • 1.7982
  • 2.3711
  • 3.5898
  • 1.0185
  • 1.0324 *

.9211

  • 1.3034 *
  • 2.2840
  • 2.9441
  • 2.9600
  • 3.3377
  • M-SUB-Q AT 75% POWER, 4 EFPD, THIS IS LEVEL 9 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTCM)

H G

F E

D C

B A

8

  • 1.1288
  • 1.5037
  • 1.2831
  • 1.5530
  • 1.3955
  • 1.6022
  • 1.3313
  • 1.2616 *
  • 2.6552
  • 1.9968
  • 2.3372
  • 1.9313
  • 2.1450
  • 1.8665
  • 2.2294
  • 2.3372
  • 9* 1.5037
  • 1.3355
  • 1.5358
  • 1.3934
  • 1.6606
  • 1.5530
  • 1.6461 *

.9896 *

  • 1.9968
  • 2.2464
  • 1.9557
  • 2.1560
  • 1.0015
  • 1.9326
  • 1.8226
  • 2.9860
  • 1.5283
  • 1.2713
  • 1.5765
  • 1.5230
  • 1.6825
  • 1.4833
  • 1.0014
  • 10
  • 1.2831 2.3372
  • 1.9648
  • 2.3597
  • 1.9113
  • 1 9767
  • 1.7927
  • 2.0256
  • 2.9891
  • 11
  • 1.5530
  • 1.3869
  • 1.5679
  • 1.3859
  • 1.6815
  • 1.5165
  • 1.6697 *

.8943

  • 1.9313
  • 2.1655
  • 1.9213
  • 2.1735
  • 1.7938
  • 1.9900
  • 1.8070
  • 3.3567
  • 12
  • 1.3955
  • 1.6665
  • 1.5197
  • 1.6783
  • 1.5026
  • 1.6825
  • 1.2659 *

................................................ 7982..*. 2.3864

  • 2.1450
  • 1.8026
  • 1.9807
  • 1.7971
  • 2.0118
  • 1...

13

  • 1.6022
  • 1.5519
  • 1.6783
  • 1.5144
  • 1.6836
  • 1.2177 *.8343 *

............ 9339

  • 1. 7960
  • 1.9914
  • 1.7982
  • 2.4871
  • 3 6251 *
  • 1.8665
  • 1.

14

  • 1.3313
  • 1.6429
  • 1.4812
  • 1.6686
  • 1.2638 *

.8343

  • 1.8249
  • 2.0284
  • 1.0092
  • 2.3903
  • 3.6251 *
  • 2.2294
  • 1.0003 *

.8932

  • 1.2616 *

.9864

  • 2.3372
  • 2.9951
  • 2.9951
  • 3.3644
  • M-SUB-Q

APPENDIX Page 97 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 75% POWER, 4 EFFD, THIS IS LEVEL 8 OF 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 e DOTTOM)

.................................................C........H........A H

O F

E D

8* 1.1213

  • 1.5101
  • 1.2798
  • 1.5583
  • 1.3923
  • 1.6065
  • 1.3200
  • 1.2670 *

..................................................................... 1..*

2.1082

  • 2.183
  • 2.5898
  • 1.9130
  • 2.2446
  • 1.8328
  • 2.0382
  • 1.7637 9
  • 1.5101
  • 1.3334
  • 1.5422
  • 1.3934
  • 1.6772
  • 1.5540
  • 1.6558 *

.9853 *

  • 1.9138
  • 2.1671.*. 1.8677
  • 2 0726
  • 1.7265..*.1 0478
  • 1.7205
  • 2.8096
  • 1 j

10

  • 1.2798
  • 1.5347
  • 1.2681
  • 1.5829
  • 1.5240
  • 1.6933
  • 1.4865
  • 1.0014 *
  • 2.2446
  • 1.8772
  • 2. 2671 '.1 8351
  • 1.9101
  • 1.7255
  • 1. 9402.*.2. 8149
  • 11
  • 1.5583
  • 1.3800
  • 1.5744
  • 1.3848
  • 1.6922
  • 1.5197
  • 1.6847 *

.8921 *

  • 1.0328
  • 2.0014
  • 1,8432
  • 2.1112
  • 1.7306
  • 1.9275
  • 1.7398
  • 3.2175
  • 1.3923
  • 1.6750
  • 1.5208
  • 1.6879
  • 1.5069
  • 1.6954 + 1.2681
  • 12 *
  • 2. 0382..*. 1.7286
  • 1.9113.*. 1.7337
  • 1.9544
  • 1. 7398
  • 2.3170..*.

.8322

  • 13
  • 1.6065 ' 1.5519
  • 1.6890
  • 1.5176
  • 1.6954
  • 1.2177

......................... 5381

  • 1.7388
  • 2.4237
  • 3
  • 1.7637
  • 1.8478
  • 1.7276
  • 1.9

............................... 288

  • 14
  • 1.3280
  • 1.6526
  • 1.4844
  • 1.6825
  • 1.2670 *

.8322

  • 2.1082
  • 1.7225
  • 1.9441
  • 1.7419
  • 2.3100
  • 3.5423
  • 15
  • 1.2670 *

.9832 *

.9992 *

.8911

  • 2.8176
  • 2.8203
  • 3.

.............................. 2,210.* M-SUB-Q i

AT 75% POWER, 4 EFPD, THIS IS LEVEL 7 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8* 1.0946

  • 1.4823
  • 1.2531
  • 1.5305
  • 1.3634
  • 1.5744 + 1.2970
  • 1.2402 *
  • 2.4150
  • 1.7712
  • 2.0726
  • 1 6803
  • 1.8784
  • 1.6229
  • 1.9492
  • 2.0214
  • 9
  • 1.4823
  • 1.3066
  • 1.5144
  • 1.3655
  • 1.6472
  • 1.5200
  • 1.6247 *

.9618

  • 115..*. 1.9039
  • 1 5820
  • 1.7006
  • 1.5803
  • 2.6082
  • 1.7712
  • 2.0118
  • 1.7 10
  • 1.2531
  • 1.5069 ' 1.2413
  • 1.5551
  • 1.4930 ' 1.6633
  • 1.4566 *

.9778 *

............**.......... 3..*.1.6841..*. 1.7606

  • 1 5820
  • 1 7819
  • 2.5967 *
  • 2.0726
  • 1.7205
  • 2.087 11
  • 1.530S
  • 1.3591
  • 1.5455
  • 1.3559
  • 1.6622
  • 1.4898
  • 1.6547 *

.8718 *

  • 1 6803
  • 1.9125
  • 1.6909
  • 1.9701
  • 1 6149
  • 1.8026
  • 1.6211.*.2.9740
  • 12
  • 1.3634
  • 1.6451
  • 1.4898
  • 1.6590
  • 1.4769
  • 1.6654
  • 1.2413
  • 1.7616
  • 1.6105
  • 1.8618
  • 1.6428
  • 2.1703 *
  • 1.8784
  • 1.5837 13
  • 1.5744
  • 1.5197
  • 1.6600
  • 1.4865
  • 1.6665
  • 1.1910 *

.8118 *

  • 1.0048 1.6419
  • 2.2953
  • 3.3078 *
  • 1.6229
  • 1.7026
  • 1.5837 1.2970
  • 1.6215
  • 1.4533
  • 1.6536
  • 1.2402 *

.6118

  • 14
  • 1.9492
  • 1.5820
  • 1.7851
  • 1.6220
  • 2.1719 3.3115
  • 15
  • 1.2402 *.9585 *

.9757 *

.8697

  • 2.6151
  • 2.6013
  • 2.9770
  • M-SUH-Q
  • 2. 0214

APPENDIX Page 98 of 140 McGuire 2 Cylce 10 Core Operating Limits Report l'able 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 75% POWER, 4 EFPD, THIS IS LEVEL 6 0F 18 (LEVEL 10 3 TOP OF CORE, LEVEL 1 = BOTTOM)

H O

F E

D C

B A

8

  • 1.0560
  • 1.4309
  • 1.2092 + 1.4748
  • 1.3130
  • 1.5144
  • 1.2466
  • 1.1888 *
  • 2.2243
  • 1.6419
  • 1.9288
  • 1 5820.*.1 7701
  • 1.5334
  • 1 8478
  • 1 9263
  • 9
  • 1.4309
  • 1,2616
  • 1.4608
  • 1.3141
  • 1.5862
  • 1.4619
  • 1.5604 *

.9211 *

.............................. 7862.+. 1.4847

  • 1.6018
  • 1.4938.*.2.4829.*.
  • 1.6419
  • 1.8594
  • 1.6035
  • 1 10
  • 1.2092
  • 1.4523
  • 1.1963
  • 1.4973
  • 1.4362
  • 1.6011
  • 1.3987 *

.9361 *

  • 1.9288
  • 1.6123.*.1.9531..*. 1.5769.*.1.*.6474
  • 1.4840
  • 1.6765
  • 2.4642
  • 11
  • 1.4748
  • 1.3077
  • 1.4887
  • 1.3066
  • 1.6001
  • 1.4319
  • 1.5894 *

.8343 *

  • 1.5060
  • 2.7989 *

........................371.5820

  • 1.7949
  • 1.58..*. 1.8249.*.1.4968
  • 1.6727 12
  • 1.3130
  • 1.5840
  • 1.4330
  • 1.5969
  • 1.4201
  • 1.6022
  • 1.1888 *

.....................................***.......... 39

  • 2.0228
  • 1.7701 + 1.4862
  • 1.6493
  • 1.4999
  • 1.7195
  • 1.52

.7765

  • 13
  • 1.5144
  • 1.4598
  • 1.5979
  • 1.4298
  • 1.6022
  • 1.1417
  • 1,5334
  • 1.6044
  • 1.4855
  • 1.6746
  • 1.5239
  • 2.1419
  • 3.1023.*.

14

  • 1.2466
  • 1.5583
  • 1.3966
  • 1.5883
  • 1.1877 *

.7754 *

  • 1.8478
  • 1.4968
  • 1.6793
  • 1.5075.*. 2. 0256.*. 3.1056
  • 15
  • 1.1888 *

.9189 *

.9339 *

.8332

  • 2.4913
  • 2.4684
  • 2.8015
  • M-SUB-Q AT 75% POWER, 4 EFPD, THIS IS LEVEL 5 0F 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 = BOTI'OM) l H

G F

E D

C B

A j

8

  • 1.0421
  • 1.4255
  • 1.1984
  • 1.4651
  • 1.2970
  • 1.4994
  • 1.2263
  • 1.1727
  • i
  • 2.0453
  • 1.5060
  • 1.7819.*. 1. 4641..*. 1. 6474.*. 1.4252
  • 1.7316
  • 1. 8004
  • 9* 1.4255
  • 1.2509
  • 1.4533
  • 1.3002
  • 1.5712
  • 1.4416
  • 1.5444 *

.9039 *

....**....... 095

  • 1.4773.*. 1 6548
  • 1.3734
  • 1.4908
  • 1.3889
  • 2. 3354 *
  • 1.5060
  • 1.7............

10

  • 1.1984
  • 1.4459
  • 1.1835
  • 1.4833
  • 1.4159
  • 1.5840
  • 1.3784 *

.9200 *

..................................................... 5594

  • 2. 3061.*
  • 1 1819
  • 1.4855
  • 1.8081
  • 1.4561
  • 1.5271
  • 1.3721
  • 1.......

11

  • 1.4651
  • 1.2938
  • 1.4748
  • 1.2884
  • 1.5840
  • 1.4105
  • 1.5722 *

.8172 *

..................................... 1.3753

  • 1.5422
  • 1 3843
  • 2.6151
  • 1.4641
  • 1.6623
  • 1.4626
  • 1.6812
  • 12
  • 1.2970
  • 1.5690
  • 1.4126
  • 1.5797
  • 1.3992
  • 1.5840
  • 1.1695 *
  • 1.6474
  • 1.3753
  • 1.5286
  • 1.3778
  • 1.5652
  • 1.3869
  • 1.8630
  • 13
  • 1.4994
  • 1.4394
  • 1.5008
  • 1.4084
  • 1.5840
  • 1.1203 *

.7593

  • 1.4252
  • 1.4923
  • 1.3740
  • 1.5439
  • 1.3863
  • 1.9583
  • 2.8558
  • 14
  • 1.2263
  • 1.5422
  • 1.3762
  • 1.5701
  • 1.1674 *

.7593

  • 1.5619
  • 1.3863
  • 1.8641
  • 2.8586 *
  • 1. 7316
  • 1.3909
  • 15
  • 1.1727 *

.9007 *

.9178 *

.8161

  • 1.8004
  • 2.3428
  • 2. 3097
  • 2.6174
  • M-EUB-Q

APPENDDC Page 99 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 75% POWER, 4 EFPD, THIS IS LEVEL 4 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

H O

F E

D C

B A

8

  • 1.0003
  • 1.3645
  • 1.1503
  • 1.3907
  • 1.2402
  • 1.4255
  • 1.1610
  • 1.1010 *

.......................................... 1. 7938 *

  • 1.6087
  • 1.3988
  • 1.7085 *
1. 7286
  • 1.4314
  • 1.9807
  • 1.4634
  • 9
  • 1.3645
  • 1.2006
  • 1.3912
  • 1.2402
  • 1.4887
  • 1.3655
  • 1.4576 *

.8514 *

............. 567 *..... 1. 4391

  • 1 6158
  • 1.3495
  • 1. 4663
  • 1.3734.*. 2.3206 *
  • 1.4634
  • 1.6 10
  • 1.1503
  • 1.3827
  • 1.1342
  • 1.4094
  • 1.3409
  • 1.4983
  • 1.3002 *

.8643 *

  • 1 7286
  • 1.4468
  • 1. 7564.*.1 4231
  • 1 4976
  • 1.3476.*.1.5390
  • 2 2936
  • 11
  • 1.3907
  • 1.2330
  • 1.4030
  • 1.2274
  • 1.4973
  • 1.3323
  • 1.4758 *

.7668

  • 1.3670
  • 2.5944 *

....................................... 3488

  • 1.5137 1.4314
  • 1.6229
  • 1.4300
  • 1.6373
  • 1 12
  • 1.2402
  • 1.4865
  • 1.3377
  • 1.4940
  • 1.3227
  • 1.4919
  • 1.0967
  • 1.6087
  • 1.3507
  • 1.4991
  • 1.3513
  • 1.5296
  • 1.3588
  • 1.0374
  • 13
  • 1.4255
  • 1.3634
  • 1.4951
  • 1.3302
  • 1.4930
  • 1.0528 *.7111
  • 2.8203 *
  • 1.3988
  • 1.4677
  • 1.3501
  • 1.5153
  • 1.3588
  • 1.9213 1.1610
  • 1.4544
  • 1.2981
  • 1.4748
  • 1.0956 *

.7111

  • 14
  • 1.7085
  • 1.3753
  • 1.5422
  • 1.3603
  • 1.8397
  • 2.8203
  • 15
  • 1.1010 *

.8493 *

.8632 *

.7658

  • 2.2971
  • 2.5990
  • M-SUB-Q
  • 1.7938
  • AT 75% POWER.

4 EFPD, THIS IS LEVEL 3 0F 18 (LEVEL 10 : TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.9757

  • 1.3302
  • 1.1245
  • 1.3500
  • 1.2049
  • 1.3698
  • 1.1042
  • 1.0357 *
  • 1.9263
  • 1.4224
  • 1.6755
  • 1.3961
  • 1.5685
  • 1.3778
  • 1.7036
  • 1.8114
  • 9
  • 1.3302
  • 1.1706
  • 1.3500
  • 1.2070
  • 1.4266
  • 1.3066
  • 1.3827 *

.0043

  • 1.4224
  • 1.6087
  • 1.3955
  • 1.5710
  • 1.3324
  • 1.4504
  • 1.3708
  • 2.3335
  • 10
  • 1.1245
  • 1.3505
  • 1.1096
  • 1.3666
  • 1.2852
  • 1.4276
  • 1.2338 *

.8150 *

. 1. 6755

  • 1.4034
  • 1.7016
  • 1.3895
  • 1. 4758
  • 1.3324
  • 1.5358
  • 2.3079
  • 11
  • 1.3580
  • 1.2006
  • 1.3602
  • 1.1856
  • 1.4276
  • 1.2681
  • 1.3880
  • 7106 *

................................. 1. 3354

  • 1.5014
  • 1. 3721
  • 2.6244
  • 1.6000 *
  • 1. 3961
  • 1.5786
  • 1.3961
  • 12
  • 1.2049
  • 1.4255
  • 1.2841
  • 1.4244
  • 1.2606
  • 1.4137
  • 1.0314 *
  • 1.5685
  • 1.3342
  • 1.4773
  • 1.3378
  • 1.5122
  • 1.3526
  • 1.8455
  • 13
  • 1.3698
  • 1.3045
  • 1.4255
  • 1.2659
  • 1.4137 *

.9917 *

.6662 *

................................................... 5

  • 2.8421
  • 1.3778
  • 1.4518
  • 1.3342
  • 1.5037
  • 1.3519
  • 1.922 14
  • 1.1042
  • 1.3805
  • 1.2316
  • 1.3869
  • 1.0303 *

.6662 *

  • 1.7036
  • 1.3734
  • 1.5382
  • 1.3734
  • 1.8466
  • 2.8421 *
  • ......................e...............................

.8022 *

.8129 *

.7176

  • 1.0357

.............................. 6291.*. M-SUB-Q 1.8114

  • 2.3391
  • 2 3115
  • 2

APPENDIX Page 100 ' f 140 o

McGuire 2 Cylce 10 Core Operating Limits Report Table 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 75% POWER, 4 EFFD, THIS IS LEVEL 2 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 : BOTTOM)

...................**.....................................B.........A H

G F

E D

C 8*

.90LB

  • 1.2124
  • 1.0367
  • 1.2424
  • 1.1085
  • 1.2102 *.9682 *

.8729 *

.................................................................. 0740 *

  • 2.0090
  • 1.5022
  • 1.7512
  • 1.4707
  • 1.6428
  • 1.5022
  • 1.8748
  • 2.

9

  • 1.2124 + 1.0699
  • 1.2466
  • 1.1192
  • 1.27:3
  • 1.1599
  • 1.1995 *

.7004 *

  • 1.5022
  • 1.6958
  • 1.4626
  • 1 6301
  • 1 4398
  • 1.5710
  • 1.5208
  • 2.5830
  • 10
  • 1.0367
  • 1.2402
  • 1.0314
  • 1.2402
  • 1.1545
  • 1.2638 *

.0753 *

.6994 *

  • 1.7512..*. 1.4707 *........ 1. 7637
  • 1 4729..*. 1 5811
  • 1. 4476
  • 1.6967
  • 2. 5921..*

11

  • 1.2424
  • 1.1138
  • 1.2349
  • 1.0849
  • 1.2670
  • 1.1213
  • 1.1738 *

.6115 *

................................................................ 2. 9680 *

  • 1.4707
  • 1.6383
  • 1.4795
  • 1.6822
  • 1.4476
  • 1.6310
  • 1.5586
  • 12
  • 1.1085
  • 1.2691
  • 1.1524
  • 1.2638
  • 1.1192
  • 1.2231 *

.8846 *

  • 1. 6420
  • 1.4419
  • 1 5828
  • 1.4511
  • 1.6364
  • 1. 4999
  • 2.0682
  • 13
  • 1.2102
  • 1.1588
  • 1.2616
  • 1.1192
  • 1.2242 *

.8622 *

.5719 *

  • 1.5022
  • 1.5735
  • 1.4490
  • 1.6337
  • 1.4991
  • 2.1234
  • 3.1862
  • 14 *

.9682

  • 1.1984
  • 1.0731
  • 1.1727 *

.8836 *

.5719 *

  • 1.8748
  • 1.5223.*. 1. 6997
  • 1. 5602.*.2.0697
  • 3.1862
  • 15 *

.8729 *

.6994 *

.6993 *

.6115

  • 2.0740
  • 2.5898
  • 2.5967
  • 2.9710
  • M-SUB-Q AT 75% POWER, 4 EFPD, THIS IS LEVEL 1 CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.6512 *

.8589 *

.7047 *

.9061 *

.7647 *

.7786 *

.6394 *

.5205

  • 1.9635
  • 2.3206
  • 2.2776
  • 2.7725
  • 3.3954 *
  • 2. 7188
  • 2.0653
  • 2. 5147 9*

.8589

  • 7133 *

.8836 *

.7936 *

.9125 *

.7443 *

.7000 *

.4584 *

  • 2.0653
  • 2 4808
  • 2.0104
  • 2.2395
  • 1.9492
  • 2.3883
  • 2.2758
  • 3 8627 *

............................e.............

.9007 *

.7711 *

.8846 *

.6769 *

.4391

  • 10 *

.7047 *

.8804 *

.7197

.............. 9740

  • 2. 3043
  • 2.0131.*. 2.6268
  • 4.0263 *
  • 2.5147
  • 2.0159
  • 2.4604
  • 1.....................

11 *

.9061 *

.7893 *

.8964 *

.7347 *

.8911 *

.7283 *

.7251 *

.3856 *

  • 1.9635
  • 2.2498
  • 1. 9847
  • 2.4197
  • 2.0008
  • 2.4458
  • 2.4540
  • 4.5978
  • 12 *

.7647 *

.9104 *

.7690 *

.8879

  • 7326 *

.7915 *

.55.37

............................ 2.0076

  • 2.4297
  • 2.2532
  • 3.2140 *
  • 2.3206
  • 1.9544
  • 2.3115
  • 13 *

.7786 *

.7433 *

.8836 *

.7272 *

.7925 *

.5623 *

.3641 *

................................................ 1691.*. 4.8714.*.

  • 2.2776
  • 2.3903
  • 2.0154
  • 2.4499
  • 2.2532
  • 3.....

14 *

.6394

  • 7797 *

.6758 *

.7251 *

.5537 *

.3641 *

  • 2.7725
  • 2.2794
  • 2.6291.*.2. 4581.**3.2175
  • 4.8714 *

.3845

.5205 *

.4573 *

.4391

  • 3.3954
  • 3.8677
  • 4.0318
  • 4.5978
  • M-SUB-Q

........................+...........

APPENDIX Page 101 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 2 (cont.)

F-sub-Q/M sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 50% FOWER, 4 EFPD, THIS IS LEVEL 18 CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 3 BOTTOM)

H G

F E

D C

B A

8*

.6726 *

.9521 *

.8622

  • 1.0721 *

.9468 *

.9468 *

.8150 *

.6512 *

................................ 22.*.2. 4167

  • 2.4009
  • 2 7794
  • 3. 4366 *
  • 2.8598
  • 2.3035
  • 2.6909
  • 2.14 9*

.9521 *

.8300

  • 1.0303 *.9468
  • 1.0609 *.8986 *

.9307 *

.5912 *

  • 2.3035
  • 2 6820
  • 2. 2541..*.2.4282
  • 2.1456
  • 2.5376.*.2. 4385.*. 3.7970
  • 10 *

.8622

  • 1.0292 *

.8771

  • 1.0324 *

.9010

  • 1.0089 *

.8140 *

.5494 *

  • 2.6909
  • 2.2554
  • 2.6539
  • 2 2508
  • 2.5708
  • 2.2971
  • 2.8220
  • 4.1337 *

.9468

  • 1.0282 *

.8450 *

.9361 *

.7947 *.0022 *.4691

  • 11
  • 1.0721 2.7538
  • 4.8666
  • 2.6914 *
  • 2.1422
  • 2.4311
  • 2.2597
  • 2.6591
  • 2.2576 12 *

.9468

  • 1.0699 *

.8996 *

.9328 *

.6640

  • 7261 *

.6000 *

........................ 3

  • 2.2639
  • 2.6322
  • 2.4818
  • 3.4196 *
  • 2.4167
  • 2.1456
  • 2.577.......................................

13 *

.9468 *

.8986

  • 1.0070 *

.7936 *

.7261 *

.5119 *.3898 *

.............................. 6933

  • 2.4804.*. 3.3162.*. 4.9522
  • 2.4009
  • 2.5392
  • 2.2997
  • 2 14 *

.8150 *

.9286 *.8129 *

.8022 *

.6000 *.3898 *

  • 2.7794
  • 2.4429
  • 2.6259
  • 2.7558
  • 3.4225
  • 4.9522
  • 15 *

.6512 *

.5901 *

.5404 *

.4680

  • 3.4366
  • 3.8041
  • 4.1379
  • 4.8724
  • M-SUB-Q AT 50% F0WER, 4 EFPD, 1HIS IS LEVEL 17 OF 18 (LEVEL 18 e TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.9350

  • 1.2895
  • 1.1867
  • 1.3741
  • 1.3034
  • 1.3966
  • 1.1792
  • 1.0271
  • 2.2300
  • 1.8324
  • 2.0364
  • 1.7597
  • 1.8457
  • 1.7006
  • 2.0095
  • 2.2886
  • 9* 1.2095
  • 1.1856
  • 1.3645
  • 1.2681
  • 1.3923
  • 1.3548
  • 1.3505 *.8654 *

. 1 0324

  • 1. 9775
  • 1.7950
  • 1. 9098
  • 1.7236
  • 1.7600
  • 1. 7734
  • 2 7245
  • 10
  • 1.1867
  • 1.3602
  • 1.1910
  • 1.3473
  • 1.2991
  • 1.3762
  • 1.2199 *

.8311 *

  • 2.0364
  • 1.8013
  • 2.0639
  • 1.0204
  • 1 8822
  • 1.7749
  • 1.9920
  • 2.b?27 *

.7197

  • 11
  • 1.3741
  • 1.2670
  • 1.3430
  • 1.1856
  • 1.2916
  • 1.1931
  • 1.2327
  • 3.3511
  • 1.7597
  • 1.9125
  • 1.0260
  • 1.9854
  • 1.7858
  • 1.9204
  • 1.8887 12
  • 1.3034
  • 1.3944
  • 1.2970
  • 1.2895 *

.9778

  • 1.1149 *.9393
  • 1.7963
  • 2.3611
  • 1.7881
  • 1.8951
  • 1.8457
  • 1.7215
  • 1.8847

)

13 + 1.3966

  • 1.3548
  • 1.3752
  • 1.1920
  • 1.1149 *

.8129 *

.6094

  • l 1.9222
  • 1.7955
  • 2.3616
  • 3.4540 *
  • 1.7086
  • 1.7680
  • 1.7764 3

14

  • 1.1792
  • 1.3495
  • 1.2188
  • 1.2316 *

.9382 *

.6083

  • 1.9949
  • 1.0904
  • 2.3625
  • 3.4567
  • 2.0095
  • 1.7757

.8632 *

.8300 *

.7176

  • 1.0271

..... 66

  • 2.7318
  • 2.8768
  • 3.3565
  • M-SUB-Q 2.28

APPENDIX Page 102 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 50% POWER, 4 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BO'liOM)

H G

F E

D A

.................................................C.......D 8

  • 1.1031
  • 1.4748
  • 1.3120
  • 1.5369
  • 1.4276
  • 1.5915
  • 1.3398
  • 1.2167 *
  • 2 2010
  • 1.7479
  • 1 9940
  • 1.6735
  • 1.7849
  • 1.5896
  • 1. 8745
  • 2.0449
  • 9
  • 1.4748
  • 1.3313
  • 1.5230
  • 1.3869
  • 1.5915
  • 1.5422
  • 1.5787 *

.9896 *

  • 1.7479
  • 1. 9169
  • 1. 7203.*. 1 0645
  • 1.6012
  • 1. 6498
  • 1.6110..*.2.5250.*.

10

  • 1.3120
  • 1.5176
  • 1.2970
  • 1.5176
  • 1.4748
  • 1.5872
  • 1.4201 *

.9703 *

............... 2.0290

  • 1 7289
  • 1. 7702
  • 1.6446
  • 1 8246
  • 2. 6166 *
  • 1 9940
  • 1.7267 11
  • 1.5369
  • 1.3827
  • 1.5133
  • 1.3248
  • 1.5294
  • 1.4052
  • 1.5005 *

.8493

  • 1.7353
  • 1.9101
  • 1.6516
  • 1.7841
  • 1.6791
  • 3.0428
  • 1.6735
  • 1.8661 12
  • 1.4276
  • 1.5936
  • 1.4737
  • 1.5272
  • 1.2906
  • 1.4319
  • 1.1449
  • 1.7732
  • 1.6536
  • 1.7648
  • 1.6313
  • 2.1360 *
  • 1.7849
  • 1.5987 13
  • 1.5915
  • 1.5422
  • 1.5862
  • 1.4041
  • 1.4319
  • 1.0485 *

.7476 *

................................. 4

  • 1.6301
  • 2.1708
  • 3.1498 *
  • 1.5896 + 1.6504
  • 1.6465
  • 1.786.............................

14

  • 1.3198
  • 1.5765
  • 1.4100
  • 1.4994 + 1.1438 *

.7465 *

  • 1.8745
  • 1.6135
  • 1.8278
  • 1.6804
  • 2.1371
  • 3.1521 *

.9864 *

.9693 *

.8482

  • 1.2167
  • 2.0449
  • 2.5326
  • 2.6215
  • 3.0473
  • M-SUB-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 15 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

A

........................................D.........C.......B.............

1.3730

  • 1.6250
  • 1.4908
  • 1.6858
  • 1.4148
  • 1.3120
  • 8
  • 1.2102
  • 1.5787 *

.......... 1.0035

  • 2 0837
  • 1.7124
  • 1.0440
  • 1.6179
  • 1.9094
  • 2.0386
  • 2.3176
  • 1.4169
  • 1.6108
  • 1.4641
  • 1.7136
  • 1.6333
  • 1.7029
  • 1.0496
  • 9
  • 1.5787 *

+ 1.6216

  • 1.6806
  • 1.6087
  • 2.5609 *

................... 1. 7687

  • 1.9347
  • 1.8035
  • 2.0026
  • 10
  • 1.3730
  • 1.6044
  • 1.3527
  • 1.6204
  • 1.5797
  • 1.7115
  • 1.5326
  • 1.0432 *
  • 2.0837
  • 1.7761
  • 2 1109
  • 1.7581
  • 1.7983.*. 1.6531
  • 1.8289
  • 2.6258
  • 1.6140
  • 1.4223
  • 1.6836
  • 1.5390
  • 1.6643 *.9200
  • 11
  • 1.6250
  • 1.4587 1.8050
  • 1.6670
  • 3.0487
  • 1.9690
  • 1.6561 1.9355
  • 1.7647
  • 1.7124 12
  • 1.4908
  • 1.7115
  • 1.5787
  • 1.6815
  • 1.4993
  • 1.6504
  • 1.2723 *

................... 1 8014

  • 1.6554
  • 1.7863.*. 1.6300
  • 2.1419 *
  • 1,8440
  • 1.6197 13
  • 1.6850
  • 1.6322
  • 1.7104
  • 1.5369
  • 1.6504
  • 1.2092 *.8354
  • 1.0073
  • 1.6293
  • 2.1865
  • 3.1797
  • 1.6813
  • 1.6551 *
  • 1.6179
  • 14
  • 1.4148
  • 1.7007
  • 1.5305
  • 1 6633
  • 1.2713 *

.8343

  • 1.9094
  • 1.6117
  • 1.8313
  • 1.6677
  • 2.1441
  • 3.1821
  • 15
  • 1.3120
  • 1.0464
  • 1.0410
  • 9189
  • 3.0540
  • M-sva-Q
  • 2.0386
  • 2.5671

1 APPENDLX Page 103 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 2 (cont.)

i F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 50% POWER, 4 EFfD, THIS IS LEVEL 14 0F 18 (LEVEL 18 : TCP OF CORE, LEVEL 1 = BOTTOM) i

...............................E.........D.......C.......B.......A H

G F

  • 2.5614
  • 1.9705..*. 2 2723
  • 1. 8788
  • 2. 0289
  • 1.7731.*. 2.08 i

1.2134

  • 1.5829
  • 1.3687
  • 1.6279
  • 1.4855
  • 1.6868
  • 1.4148
  • 8*

J 9

  • 1.5929
  • 1.4212
  • 1.6108
  • 1.4673
  • 1.7329
  • 1.6418
  • 1.7179
  • 1.0507
  • f
  • 1. 9705..*.2.2032.*. 1.9210
  • 2. 1063
  • 1. 7731.*.1. 0419..*. 1.7487
  • 2 7981..*.

I 10

  • 1.3687
  • 1.6044
  • 1.3495
  • 1.6322
  • 1.5958
  • 1.7329
  • 1.5508
  • 1.0496 *
  • 2 2723
  • 1.9287
  • 2 2939
  • 1 0909
  • 1.9297
  • 1.7731..*.1 9689
  • 2.8611
  • 11
  • 1.6279
  • 1.4619
  • 1.6268
  • 1.4437
  • 1.7232
  • 1.5722
  • 1.7061 *.9339 *
  • 1.8788
  • 2.1145..*. 1 8976
  • 2. 1419
  • 1.7893
  • 1.9529
  • 1. 7909
  • 3.2559
  • j 12
  • 1.4855
  • 1.7307
  • 1.5936
  • 1.7200
  • 1.5465
  • 1.7093
  • 1.3066 *

...................... 313

  • 1. 7922
  • 1.9455.*.1.7668.*. 2.3230 *
  • 2.0289
  • 1.7702
  • 1.9.........................

13

  • 1.6868
  • 1.6408
  • 1.7307
  • 1.5701
  • 1.7093
  • 1.2541 *

.8611 *

.............. 27

  • 1. 7753.*. 1.9555
  • 1. 7665.*.2. 3873.*. 3.4740 *
  • 1.7731
  • 1.84.........

14

  • 1.4148
  • 1.7147
  • 1.5476
  • 1.7050
  • 1.3055 *

.8600 *

  • 2 0898
  • 1.7515
  • 1.9716
  • 1.7924
  • 2.3249
  • 3.4768
  • 15
  • 1.3173
  • 1.0474
  • 1.0485 *

.9318

  • 2.2175.*. 2.0072
  • 2.8668
  • 3.2631
  • M-SUB-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 13 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 BOTTOM)

H G

F E

D C

B A

8* 1.2295

  • 1.6215
  • 1.3891
  • 1.6675
  • 1.5112
  • 1.7275
  • 1.4416
  • 1.3548 *
  • 2.7934
  • 2.1156
  • 2.4604
  • 2 0373
  • 2.2142
  • 1.9197
  • 2.2692..*. 2.3787
  • 9
  • 1.6215
  • 1.4459
  • 1.6504
  • 1.5026
  • 1.7864
  • 1.6836
  • 1.7704
  • 1.0710 *

............... 2.0730

  • 2.2763
  • 1.9025
  • 1.9993
  • 1.8793
  • 3.0293 *
  • 2 1156
  • 2.3727
  • 10
  • 1.3891
  • 1.6429
  • 1.3720
  • 1.6793
  • 1.6397
  • 1.7896
  • 1.5958
  • 1.0774
  • 2.1139
  • 3.0847

..... 84

  • 2. 0827
  • 2.4936
  • 2.0292
  • 2.0732
  • 1. 8951 2.46 1.6675
  • 1.4962
  • 1.6718
  • 1.4833
  • 1.7886
  • 1.6258
  • 1.7779 *

.9607

  • 11 *
  • 2.0373
  • 2.2857
  • 2.0395
  • 2.2976
  • 1.8967
  • 2.0840
  • 1.0917
  • 3.4924
  • 12
  • 1.5112
  • 1.7843
  • 1.63i6
  • 1.7854
  • 1.6054
  • 1.7843
  • 1.3559 *
  • 2.2142
  • 1.9041
  • 2. 0762
  • 1.9007
  • 2.1097
  • 1 8973
  • 2.4880
  • 13
  • 1.7275
  • 1.6815
  • 1.7864
  • 1.6236
  • 1.7843
  • 1.3023 *.8921 *
  • 1.9197
  • 1.9993
  • 1 8983
  • 2.0869
  • 1 8965
  • 2.5961..*.3.7695
  • 14
  • 1.4416
  • 1.7671
  • 1.5936
  • 1.7768
  • 1.3548 *.8911 *
  • 2.2692
  • 1.8826
  • 2.1170
  • 1.8934
  • 2.4907
  • 3.7727
  • 15
  • 1.3548
  • 1.0678
  • 1.0753 *

.9585

  • 2.2787
  • 3.0377
  • 3.0890
  • 3.5008
  • M-SUB-Q L

~

,a.4 y/,

1 3

1:

4 APPENDIX Page 104 of 140 -

McGuire 2 Cylce 10 Core Operating Limits Report 10able 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 50% POWER, 4 EFPD, THIS IS LEVEL 12 OF 18 (LEVEL 18 s TOP OF CORE, LEVEL 1 = BOTTOM)

...............................E.........D........C.........B.........A....

H G

F 8

  • 1.2092
  • 1.6033
  • 1.3698
  • 1.6526
  • 1.4930
  • 1.7104
  • 1.4234
  • 1.3409 *
  • 3.1743..'. 2. 3925..*. 2 8017
  • 2. 2555
  • 2. 4560
  • 2 1234*-2. 5076 '.2 6159
  • 9
  • 1.6033 ' 1.4266
  • 1.6343
  • 1.4876
  • 1.7757
  • 1.6665
  • 1.7564
  • 1.0571 *

... 3925 '.2. 6896

  • 2 3433
  • 2. 5759
  • 2 1162
  • 2.2137
  • 2.0697
  • 3. 3440 *
  • 2 10
  • 1.3698
  • 1.6268 *.1.3548 1.6718
  • 1.6279
  • 1.7854
  • 1.5840'* 1.0656 *

. 2. 8017

  • 2.3545..*.2. 8268
  • 2.2796
  • 2. 3361..*.2.1249
  • 2.3653..*.3. 3954
  • 11 ' 1.6526
  • 1.4812
  • 1.6633
  • 1.4737
  • 1.7832
  • 1.6183
  • 1.7746 *.9521 *
  • 2. 2555
  • 2 5838
  • 2. 2914
  • 2.5865
  • 2. 1259
  • 2.3412 '. 2. 1158
  • 3.9348
  • 12
  • 1.4930
  • 1.7736
  • 1.6247 ' 1.7800
  • 1.6001
  • 1.7832
  • 1.3495 *
  • 2. 4560
  • 2.1142
  • 2. 3411..*. 2.1300
  • 2. 3610
  • 2. 1167
  • 2 7864
  • 13
  • 1.7104
  • 1.6654
  • 1.7811
  • 1.6151 ' 1.7843 ' 1.2901 *.8868 *
  • 2 1234
  • 2 2148
  • 2.1289
  • 2 3437
  • 2 1157
  • 2.8991.*.4. 2107
  • 14
  • 1.4234
  • 1.7532
  • 1.5808
  • 1.7725
  • 1.3484 *.8857 *

. 2. 5076.*.2.0736

  • 2. 3691..*.2.1178..'.2.7897
  • 4 2147
  • 15
  • 1.3409
  • 1.0539
  • 1.0646 *. 9500

. 2. 6159

  • 3 3517..*. 3. 4006
  • 3.9418..* M-SUB-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 11 0F 18 (LEVEL 10 m TOP OF CORE, LEVEL 1 : BOTTOM)'

i -

    • ..H.........G.....***.F.........E..................C.........B.........A.....

D 8* 1.1760

  • 1.5647
  • 1.3355
  • 1.6151
  • 1.4566
  • 1.6697
  • 1.3800
  • 1.3077 *
  • 3. 6840 ' 2 7561.*. 3.2269..*. 2. 5061.*. 2 7323
  • 2.3616
  • 2. 7927
  • 2. 9046.*

9

  • 1 5647
  • 1.3902
  • 1.5969
  • 1.4523
  • 1.7382 ' 1.6268
  • 1.7168-* 1.0292 *
  • 2 7561..*.3 1089.'.2 6283..*.2. 8725..*.2 3503 '.2. 4656
  • 2. 2977
  • 3.'7212..*

10

  • 1.3355
  • 1.5894 ' 1.3227
  • 1.6386
  • 1.5915
  • 1.7511
  • 1.5476
  • 1.0389 *
  • 3. 2269
  • 2. 6409
  • 3.2001..*.2. 5688
  • 2.6567.'..'2. 3742
  • 2. 6221.*. 3.7624.*.

11

  • 1.6151
  • 1.4469
  • 1.6290
  • 1.4426
  • 1.7500
  • 1.5840
  • 1.7393 *.9286 *
  • 2. 5061.*.2.8781..*.2. 5777
  • 2. 9959
  • 2. 4587
  • 2. 7126
  • 2. 4455..*. 4. 4032..*

12

  • 1.4566
  • 1.7361
  • 1.5883 + 1.7457
  • 1.5679
  • 1,7511
  • 1.3195 *
  • 2.7323
  • 2.3478
  • 2 6599
  • 2.4630
  • 2 73.*36
  • 2.4440 '. 3.2278
  • 13
  • 1.6697
  • 1.6247
  • 1.7468
  • 1.5808
  • 1.7511
  • 1.2702 *.8664 *
  • 2 3616
  • 2.4670..*. 2 3768
  • 2 7169
  • 2. 4427
  • 3. 3550
  • 4.8717
  • 14
  • 1.3880
  • 1.7147
  • 1.5444
  • 1.7372 ' 1.3184 *.8654 *
  • 2. 7927..*.2.3013
  • 2. 6268 '. 2. 4482
  • 3.2323..*.4.8766
  • 4 15
  • 1.3077 ' 1.0260
  • 1.0378 *.9275
  • 2. 9046..*.3 7307
  • 3 7656.*. 4 4120..* M-SUB-Q s

I 1

l.

APPENDIX ~

Page 105 of 140 McGuire 2 Cylce 10 Core Operating Limits Report -

liable 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 50% POWER, 4 EFPD, ~THIS IS LEVEL 10 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 's BOTTOM)

........................................D.........C........D.........A H

G F

E 8

  • 1.1588
  • 1.5551
  • 1.3205
  • 1.6076
  • 1.4416
  • 1.6590
  • 1.3730
  • 1.3013 *

... 9296

  • 2.9316
  • 3.4484
  • 2.7272 '.2 9951.'.2. 5762..+.3. 0510..*. 3 1376.*
  • 3...................................

9 1.5551 ' 1.3762

  • 1.5894
  • 1.4416
  • 1.7318
  • l',6129
  • 1.7104
  • 1.0174 *
  • 2. 9316
  • 3.3140
  • 2 8540
  • 3.1398
  • 2.5598
  • 2. 6973
  • 2. 4962..*. 4.0404.*

10

  • 1.3205
  • 1.5819
  • 1.3088
  • 1.6311
  • 1.5797
  • 1.7457
  • 1.5380
  • 1.0303 *
  • 3.4484
  • 2.8688
  • 3. 4810
  • 2. 7962..*. 2. 8894
  • 2. 5853.*. 2. 8595
  • 4.0934
  • 7 11
  • 1.6076 ' 1.4351
  • 1.6226
  • 1.4298
  • 1.7447
  • 1.5733
  • 1.7372 *.9200 *
  • 2. 7272..*.3.1443.*. 2. 8087
  • 3.1966.*.2.6205.*.2. 9065
  • 2. 6346
  • 4.8052...*

12 ' 1.4416

  • 1.7297
  • 1.5754
  • 1.7414
  • 1.5583
  • 1.7479
  • 1.3109 *
  • 2.9951.*.2 5569
  • 2.8951
  • 2.6252.*.2.9433..*.2.6268
  • 3 5003...*

13

  • 1.6590
  • 1.6108
  • 1.7425
  • 1.5712
  • 1.7479
  • 1.2606 *.8579 *

.'.................. 2.5383..*. 2.9104

  • 2. 6252
  • 3 6536
  • 5.3651...*

2.5762

  • 2.6989
  • 14
  • 1.3730 ' 1.7072
  • 1.5347
  • 1.7350
  • 1.3098 *

.8568 *

.................. 16.*

3.5030

  • 5.37
  • 3. 0510
  • 2. 5005...*.2. 8651.'.2. 6377
  • 15
  • 1.3013
  • 1.0142 + 1.0292 *

.9178 ' F-5UB-Q r

. 3 1376

  • 4 0595.*.4.0972 '.4.8157
  • M-SUB-Q I

AT 50% POWER, 4 EFPD, THIS IS LEVEL 9 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 : BOTTOM)

H G

C B

A

......................F.........E.........D..**.............................

8

  • 1.1085
  • 1.4887
  • 1.2649
  • 1.5412
  • 1.3816
  • 1.5894 ' 1.3152
  • 1.2434
  • l
  • 4.0189
  • 2.9972
  • 3 4837
  • 2.6648
  • 2.9258
  • 2 5276
  • 3.0156
  • 3.1623
  • i 9
  • 1.4887
  • 1.3173
  • 1.5230
  • 1.3805
  • 1.6611
  • 1.5433
  • 1.6386 *-.9725 *
  • 2.9972..*.3 3850 '..'2. 7839.*.3. 0594
  • 2.5104
  • 2 6536
  • 2.4794
  • 4.0558.'

10 ' 1.2649

  • 1.5155
  • 1.2541
  • 1.5658
  • 1.5133
  • 1.6761
  • 1.4737 *.9853 *

.'.3. 4837

  • 2.7980
  • 3 4111..+.2.7374
  • 2.8595.*.2. 5400...*.2.8540
  • 4.1355
  • 11'* 1.5412
  • 1.3752
  • 1.5572
  • 1.3730
  • 1.6750
  • 1.5080 '.1.6654 *.8804 *

]

  • 2. 6648
  • 3.0636.*. 2.7493..*. 3.2602.*. 2.6728
  • 2.9690
  • 2. 6923..*. 4 8957
  • i 12
  • 1.3816
  • 1.6590
  • 1.5090
  • 1.6718
  • 1.4951
  • 1.6783
  • 1 2552 '

'.2.9258

  • 2.5076
  • 2.,8632
  • 2.6793
  • 3.0053
  • 2.6809
  • 3.5796
  • 13
  • 1.5894
  • 1.5412
  • 1.6729
  • 1.5058
  • 1.6783
  • 1.2001 *.8204
  • j

.'.. 5276

  • 2.6552..*.2. 5510
  • 2.9730
  • 2.6793 '.3.7338 *.................................... 17
  • 2 5.49 14
  • 1.3152
  • 1.6354
  • 1.4705 ' 1.6643
  • 1.2541 *.8193 *
  • 3.0156
  • 2.4836
  • 2.8595
  • 2.6956
  • 3.5854
  • 5.4985..*

15

  • 1.2434 *

.9703 *.9832 *

.8782

  • 3.1623
  • 4.0707
  • 4.1394 '.4.9066
  • M-SUB-Q

.rL r

i-,m

.nc

.,,i-

.+

~ - -

- - - - - - =, - - -

APPENDIX Page 106aaf 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation A7 50% POWER.

4 EFPD, THIS IS LEVEL 8 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8

  • 1.0881
  • 1.4758
  • 1.2456
  • 1.5262
  • 1.3602
  • 1.5712
  • 1.2938
  • 1.2327 *

... 9192

  • 2.8669.*. 3.2942.*. 2. 5161..*.2. 7839...*.2. 3909.*.2.8688
  • 2. 9730..*
  • 3.

1.5101

  • 1.3634
  • 1.6472
  • 1.5230
  • 1.6247 *

.9564

  • 9
  • 1.4758
  • 1.2991 *
  • 2.8669
  • 3.2602
  • 2. 6205
  • 2.9008
  • 2.3730
  • 2 5176..*. 2.3391.*.3. 8442.*

10

  • 1.2456
  • 1.5015
  • 1.2359
  • 1.5519
  • 1.4940
  • 1.6633
  • 1.4566 *

.9714 *

  • 3.2942
  • 2.6346
  • 3.2316
  • 2. 5008
  • 2. 7072
  • 2.4026
  • 2. 7006
  • 3. 9157
  • 11
  • 1.5262
  • 1.3570
  • 1.5433
  • 1.3537
  • 1.6622
  • 1.4908
  • 1.6558 *

.8664 *

............................... 2. 5974.*.2.8970

  • 2.6051.*.4.6535 *
  • 2.9065
  • 2.5929
  • 3.1805 *
    • .. 161
  • 2.5 12
  • 1.3602
  • 1.6451
  • 1.4908
  • 1.6590
  • 1.4780
  • 1.6665
  • 1.2413 *
  • 2.7839
  • 2.3704
  • 2.7122.*.2.6020
  • 2.9670
  • 2.6346 *.............................. 30
  • 3.50 13
  • 1.5712
  • 1.5208
  • 1.6600
  • 1.4807
  • 1.6675
  • 1.1920 *

.8075

  • 5.3978 *
  • 2 3909
  • 2.5190
  • 2.4065
  • 2. 9000..*.2.6330
  • 3.6994 14
  • 1.2938
  • 1.6215
  • 1.4544
  • 1.6547
  • 1.2402 *.8075 *
  • 2.8698
  • 2.3440
  • 2.7072
  • 2.6082 + 3.5086
  • 5.4044 *

.9543 *

.9703 *

.8654

  • 1.2327
  • 2.9730
  • 3.8543
  • 3.9227
  • 4.6633
  • M-SUB-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 7 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

H G

F E

D C

B A

8

  • 1.0496
  • 1.4309
  • 1.2049
  • 1.4791 *.3141
  • 1.5197
  • 1.2477
  • 1.1910 *
  • 3.6657
  • 2.6393
  • 3.0280
  • 2.3194
  • 2 5747
  • 2.2115
  • 2.6504
  • 2.7408
  • 9
  • 1.4309
  • 1.2574
  • 1.4641
  • 1.3184
  • 1.5958
  • 1.4705
  • 1.5733 *

.9211 *

  • 2.1607
  • 3.5537 *
  • 2.6393
  • 3.0135
  • 2.4118
  • 2.6777
  • 2 1918
  • 2. 3317 10
  • 1.2049
  • 1.4566
  • 1.1942
  • 1.5037
  • 1.4437
  • 1.6129
  • 1.4073 *

.9371 *

................................ 19.*. 2.5104

  • 2 2226
  • 2.5005
  • 3.6110
  • 3.0280
  • 2.4250
  • 2.9770
  • 2.38 11
  • 1.4791
  • 1.3120
  • 1.4951 + 1.3008
  • 1.6119
  • 1.4416
  • 1.6054 *

.8354 *

  • 2.3194
  • 2.6942
  • 2.3935
  • 2.9670
  • 2 4210
  • 2.7072
  • 2.4197
  • 4.2921
  • 12
  • 1.3141
  • 1.5936
  • 1.4405
  • 1.6086
  • 1.4298
  • 1.6151
  • 1.1984 *
  • 2.5747
  • 2.1896
  • 2.5133
  • 2.4264
  • 2.0051
  • 2.4604
  • 3.2795
  • 1.1503
  • 7775
  • 13
  • 1.5197
  • 1.4683
  • 1.6097
  • 1.4394
  • 1.6161
  • 2.2115...*.2.3329
  • 2. 2260
  • 2.7105
  • 2.4684
  • 3.4755
  • 5.0582
  • 14
  • 1.2477
  • 1.5701
  • 1.4052
  • 1.6033
  • 1.1974 *

.7775 *

.................... 1

  • 2.4224
  • 3.2844
  • 5.0640 *
  • 2.1650
  • 2.506
  • 2. 6504 15
  • 1.1910 *

.9189 *

.9350 *

.8343

  • 2.7400
  • 3.5652
  • 3.6177
  • 4.3004

l APPENDIX Page 107 of 140

)

McGuire 2 Cylce 10 Core Operating Limits Report Table 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 50% POWER, 4 EFPD, THIS IS LEVEL 6 0F 18 (LEVEL 18 TOP OF CORE, LEVEL 1 = DOTTOM)

H G

F E

A

........................................D.........C...*** B 8

  • 1.0003
  • 1.3645
  • 1.1492
  • 1.4084
  • 1.2509
  • 1.4437
  • 1.1835
  • 1.1267
  • 3.3773
  • 2.4506 *
  • 2.4224
  • 2.0833
  • 2.5047
  • 2.6036 *

................... 2 8212

  • 2.1777 9* 1.3645
  • 1.1995
  • 1.3944
  • 1.2541
  • 1.5165
  • 1.3944
  • 1.4919 *

.8718 *

  • 2.4506
  • 2.8033
  • 2.2555
  • 2. 5090
  • 2.0629
  • 2 1994
  • 2.0401
  • 3.3747
  • 10
  • 1.1492
  • 1.3869
  • 1.1374
  • 1.4309
  • 1.3709
  • 1.5326
  • 1.3345 *

.8857 *

............ 2683

  • 2.7821..*.2.2305
  • 2. 3540
  • 2. 0853
  • 2.3540
  • 3 4217 *
  • 2.8212
  • 2 11
  • 1.4084
  • 1.2477
  • 1.4223 + 1.2456
  • 1.5315
  • 1.3677
  • 1.5208 *

.7904 *

............................ 2 7561

  • 2.2486
  • 2.5204
  • 2.2509
  • 4 0447 *
  • 2.1777
  • 2.5147
  • 2.2407 1.3677
  • 1.5203
  • 1.3559
  • 1.5337
  • 1.1331
  • 12
  • 1.2509
  • 1.5144

............. 10

  • 2 3578
  • 2.2544
  • 2 5974
  • 2.2965
  • 3.0658 *
  • 2.4224 2.06 13
  • 1.4437
  • 1.3934
  • 1.5203
  • 1.3655
  • 1.5337
  • 1.0892 *

.7347 *

  • 2.0833
  • 2.2005.*.2 0883
  • 2.5247
  • 2.2953
  • 3.2506
  • 4.7485
  • 14
  • 1.1835
  • 1.4887
  • 1.3313
  • 1.5187 1.1320 *

.7347 *

  • 2.5047
  • 2.0430
  • 2.3590
  • 2.2544
  • 3.0700
  • 4.7536
  • 15
  • 1.1267 *

.8697 *

.8846 *

.7893

  • 3.3824
  • 3.4270
  • 4.0521
  • M-SUB-Q AT 50% POWER, 4 EFFD, THIS IS LEVEL 5 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

B A

............................**..........D........C 8*

.9768

  • 1.3441
  • 1.1256
  • 1.3827
  • 1.2209
  • 1.4105
  • 1.1492
  • 1.0988 *

..**.......................................... 1. 9246

  • 2.3341
  • 2.4210
  • 3.0321
  • 2.1961
  • 2.5732
  • 2.0004
  • 2.2452
  • 9
  • 1.3441
  • 1.1749
  • 1.3720
  • 1.2252
  • 1.4833
  • 1.3580
  • 1.4566 *

.8450 *

........ 0372

  • 1 8860
  • 3.1555
  • 9031 *2 2.1961
  • 2.5104
  • 2.0591
  • 2.3097
  • 1 10
  • 1.1256
  • 1.3645
  • 1.1128
  • 1.3998 '

45

  • 1.4973
  • 1.2981 *

.8611 *

  • 2.5732
  • 2.0697
  • 2.5495
  • 2.0420 *.

s0

  • 1.9154
  • 2.1756
  • 3.1805
  • 1.2199
  • 1.3912
  • 1.2134
  • 1.4962
  • 1.3302
  • 1.4844 *

.7647

  • 11
  • 1.3827
  • 2.0004
  • 2.3158
  • 2.0514
  • 2.4780
  • 2.0186
  • 2.2706
  • 2.0344
  • 3.7496
  • 12 + 1.2209
  • 1.4812
  • 1.3313
  • 1.4930
  • 1.3195
  • 1.4962
  • 1.1010 *
  • 2.2452
  • 1.9014
  • 2.1681.*.2.0233
  • 2. 3540
  • 2.0755
  • 2.7752
  • 13
  • 1.4105
  • 1.3570
  • 1.4940
  • 1.3280
  • 1.4973
  • 1.0549 *

.7111 *

  • 1.9246
  • 2.0302
  • 1.9179
  • 2.2729
  • 2.0755
  • 2.9690
  • 4.3384
  • 14
  • 1.1492
  • 1.4544
  • 1.2959
  • 1.4823
  • 1.0999 *

.7101

  • 2.3341 + 1.8892
  • 2.1799
  • 2.0372
  • 2.7786
  • 4.3427
  • 15
  • 1.0988 *

.8429 *

.8589 *.7636

  • 3.1645
  • 3.1873
  • 3.7560
  • M-SUB-Q

I APPENDIX Page 108 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1hable 2 (cont.)

F-sub-QfM-sub Q Values (F-sub-Q OP Margin) - Power Escalation AT 509 POWER, 4 EFPD, THIS IS LEVEL 4 0F 10 (LEVEL 18 : TOP OF CORE, LEVEL 1 BOTTOM)

H G

F B

A

...............................E.........D.........C.........................

8*

9286

  • 1.2723
  • 1.0699
  • 1.3045
  • 1.1545
  • 1.3259
  • 1.0764
  • 1.0196 *
  • 2.8744
  • 2. 0726...*.2. 4304
  • 1.9339
  • 2. 1692.*.1. 8748..*. 2. 2870
  • 2. 3987 *-

9

  • 1.2723
  • 1.1171
  • 1.2981
  • 1.1567 + 1.3902
  • 1.2723
  • 1.3500 *.7883 *
  • 2. 0726
  • 2 3730
  • 1. 9745...*.2. 2204.*.1. 8520..*.1. 9860..*. 1. 8505..*. 3. 1133..*.

10

  • 1.0699
  • 1.2906
  • 1.0549
  • 1.3152
  • 1.2499
  • 1.3987
  • 1.2102 *

.8000 *

  • 2. 4304..*. 1 9851.*. 2 4357
  • 1. 9648.*.2 0892..*. 1. 8567..*. 2 1223..*. 3. 1331..*.

c...

11

  • 1.3045
  • 1.1503
  • 1.3088
  • 1.1428
  • 1.3977
  • 1.2424
  • 1.3773 *.7101 *

... 9339..*.2 2260

  • 1 9745..*. 2. 3679
  • 1.9449
  • 2 1918...*.1. 9666..*. 3.6627.*.

~

  • 1..

12

  • 1.1545
  • 1.3880
  • 1.2466
  • 1.3944
  • 1.2327
  • 1.3934
  • 1.0207 *
  • 2.1692.5.....**....... 2..*. 1. 9501..*.2. 2373
  • 1.9851..*. 2.6907 *
  • 1.8513
  • 2.092 13
  • 1.3259
  • 1,2702
  • 1.3955
  • 1.2402
  • 1.3934 *.9800 *.6587 *
  • 1 8740
  • 1 9869.*. 1.8598
  • 2.1950
  • 1. 9842..*.2. 8302.*.4.1824
  • 14
  • 1.0764
  • 1.3559
  • 1.2001
  • 1.3752
  • 1.0196 *.6576 *
  • 2.2870..*. 1. 8536-* 2.1264.*. 1. 9683
  • 2. 6940
  • 4. 1824
  • i 15
  • 1.0196 *.7861 *.7990 *

.7090

  • 2. 3907
  • 7. 1221.*.3.1376
  • 3.6718.* M-SUB-Q I

AT 50% POWER, 4 EFPD, THIS IS LEVEL 3 0F 18

- l (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

....H..*......G.........F.........E.........D........C.........B.........A......

J

)

8*

.8964

  • 1.2284
  • 1.0357
  • 1.2552
  • 1.1106
  • 1.2C16
  • 1.0142 *.9500 *
  • 2 6009
  • 1.9544
  • 2. 2942..*. 1. 8661..*.2 0952..*.1. 8336
  • 2 2671.*.2. 4092.*-

9

  • 1.2284 *.1.0785
  • 1.2552
  • 1.1149
  • 1.3184
  • 1.2049
  • 1.2756 *.7368 *
  • 1.9544
  • 2. 2238
  • 1. 8836
  • 2. 1274
  • 1.8052
  • 1. 9475
  • 1 8328
  • 3.1111..*

10

  • 1.0357
  • 1.2477
  • 1.0217
  • 1.2627
  • 1.1856
  • 1.3195
  • 1.1363 *.7465
  • j j
  • 2. 2942.*.1.8941..*. 2. 3158
  • 1. 8CiB
  • 2 0196.*. 1. 8074
  • 2. 0892..*.3.1221..*.

- 11

  • 1.2552
  • 1.1085
  • 1.2563
  • 1.0935
  • 1.3195
  • 1.1695
  • 1.2009 *.6507 *
  • 1.8661..*.2. 1326
  • 1. 8957
  • 2.2361..*. 1 0661..*. 2 1062
  • 1. 9238.*. 3.6415..*

.1106

  • 1.3163
  • 1.1845
  • 1.3163
  • 1.1620
  • 1.3055 *.9500 *

...... 2..*.1.8074

  • 2. 0223
  • 1. 8701..*.2. 1681
  • 1. 9373.*. 2. 6299 *

. 095 13

  • 1.2616
  • 1.2027
  • 1.3163
  • 1.1674
  • 1.3055 *.9136 *.6105 *
  • 1 8336.*.1.9484
  • 1. 8103.*.2. 1092
  • 1 9364
  • 2.7962..*.4.1355..*.

14

  • 1.0142
  • 1.2734
  • 1.1342
  • 1.2798 *.9489 *.6105 *
  • 2.2671
  • 1 0359.*. 2 0942..*.1 9263
  • 2.633.0
  • 4.1394
  • 15 *

.9500 *

.7358 *.7454 *.6576

  • 2.4092
  • 3.1199
  • 3.1265..*.3.6475
  • M-SUB-Q

APPENDIX Page 109 of 140 McGuire 2 Cylce 10 Core Operating Limits Report l

1Dable 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 50% POWER, 4 EFPD, THIS IS LEVEL 2 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

D C

B A

......................F.........E..........................................

8*

.8225

  • 1.1096 *

.9468

  • 1.1385
  • 1.0132
  • 1.1042 *

.8814 *

.7936 *

  • 2.7374
  • 2. 0214
  • 2.3515
  • 1. 9509
  • 2. 1788
  • 1. 9905
  • 2 4850
  • 2.7493
  • 9
  • 1.1096 *

.9778

  • 1.1428
  • 1.0249
  • 1.1652
  • 1.0603
  • 1.0967 *

.6372 *

  • 2.0214.*. 2 2953
  • 1 9518
  • 2. 1853
  • 1.9171
  • 2.1022
  • 2.0223
  • 3.4323 *

.9468

  • 1.1363 *

.9425

  • 1.1353
  • 1.0549
  • 1.1567 *

.9810 *

.6351

  • 10 ** 2.3515
  • 1.9622
  • 2.3679
  • 1.9762
  • 2.1315
  • 1.9432
  • 2.2858
  • 3.4837
  • 11
  • 1.1385
  • 1.0196
  • 1.1299 *

.9917

  • 1.1610
  • 1.0249
  • 1.0731 *.5558
  • 1.9851
  • 2.3049
  • 1.9996
  • 2.2532
  • 2.1544
  • 4.0670 *
  • 1.9509
  • 2.1907 12
  • 1.0132
  • 1.1631
  • 1.0539
  • 1.1578
  • 1.0228
  • 1.1?92 *.8065 *

........................ 2 2776

  • 2.0912.*. 2.8875..*.

2.1346

  • 2.0040 *
  • 2.1788
  • 1. 9204 13 + 1.1042
  • 1.0592
  • 1.1545
  • 1.0228
  • 1.1192 *

.7872 *.5194 *

  • 1.9905
  • 2.1042
  • 1.9458
  • 2 2578
  • 2.0902
  • 2.9911
  • 4.5111
  • 14 *

.8814

  • 1.0946 *

.9789

  • 1.0721 *

.0065 *.5194 *

  • 2.4850
  • 2.0260
  • 2.2906.*. 2.1565
  • 2.8913
  • 4.5111
  • 15 *

.7936 *

.6351 *

.6340 *

.5558

  • 2.7493
  • 3.4403
  • 3.4892
  • 4.0707
  • M-SUB-Q AT 50% POWER, 4 EFPD, THIS IS LEVEL 1 OF 18 (LEVEL 18 m TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8*

.5901 *

.7706 *

.6303 *.8215 *

.6929 *

.7036 *.5783 *.4680 *

..................... 19

  • 3.6748
  • 4.50
  • 3.6445..*. 2. 7561..*.3 3517
  • 2.5990
  • 3.0743..*. 3.0156
  • 9*

.7786 *

.6469 *.8022 *.7197 *.8290 *.6737 *

.7058 *.4123 *

  • 2.7561..*. 3.3140
  • 2.6728
  • 2.9810..*. 2.5944
  • 3.1850
  • 3 0342..*. 5.1286
  • 10 *

.6383 *

.7990 *

.6533 *

.8182 *.6994 *.8022 *

.6126 *

.3952 *

  • 3 3517
  • 2.6793..*. 3.2942.*. 2.6425..*. 3.0893
  • 2.7022
  • 3.5170
  • 5.3978
  • 11 *

.8215 *

.7165 *

.8129 *

.6662 *

.8086 *.6587 *.6565 *

.3470 *

  • 2.5990
  • 2.9891
  • 2.6583
  • 3.2690
  • 2.7272
  • 3.3517
  • 3.3;93
  • 6.2618
  • 12 *

.6929 *

.6257 *

.E961 *

.0054 *.6640 *

.7176 *.5002 *

.........***.............. 10

  • 3.3593
  • 3.1265
  • 4.46
  • 3.0743
  • 2.5990
  • 3. 1002..*. 2.1374
  • 13
  • 7036 *

.6726 *

.8011 *

.6576 *.7176 *

.5087 *.3277 *

.............................. 3567

  • 3 1265
  • 4.4253
  • 6.8328
  • 3.0156
  • 3.1873
  • 2.7072
  • 3 14 *

.5783

  • 7047 *

.6115 *.6555 *

.5002 *

.3277 *

...................................... 5..*.6.8328

  • 3.0304
  • 3.5226
  • 3.3644
  • 4.465
  • 3. 6748
  • 15 *

.4600 *

.4113 *

.3952 *

.3459

  • P-SUB-Q
  • 4.5019
  • 5.1345
  • 5.4044
  • 6.2707
  • M-SUB-Q

E APPENDIX

' Page 110 0f 140 McGuire 2 Cylce 10 Core Operating Limits Report 10able 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation u

AT 30% POWER, 4 EFPD, THIS IS L'4 VEL 18 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 5 BOTTOM)

H G

F E

D C

, B A

8*

.7004

  • 1.0003 *.9039
  • 1.1320 *.9982
  • 1.0003 *.8568 *.6790 *
  • 2 8588
  • 2.3035.*. 2.6909..*.2. 1422..*. 2. 4167
  • 2 4009.*.2.7794..*. 3 4366..*.

9

  • 1.0003 *.8675
  • 1.0860 *.9982
  • 1.1310 *.9489 *.9821 *

.6148.'

.'.2. 3035.*. 2. 6820 '.2 2541.*.2. 4282

  • 2.1456
  • 2.5376.*. 2.4385..*. 3.7970.*

10 *

.9039

  • 1.0849 *,9200
  • 1.0881 *.9500
  • 1.0678 *.8579 *.5698 *
  • 2. 6909
  • 2 2554
  • 2. 6539.*.2. 2500
  • 2. 5708.*. 2.2971..*. 2. 8220.*.4.1337
  • 11
  • 1.1320 *.9960
  • 1.0839 *.8857 *

.9975 *.8365 *.8461 *.4852 *

..... 2597

  • 2.6591...*.2. 2576
  • 2.6914
  • 2.7538
  • 4.8666.*.
  • 2
  • 2.1422
  • 2. 4311 12 *

,9982

  • 1.1310 *.9468 *.9842 *.6951 *.7636 *

.6276 *

  • 2. 4167
  • 2.1456
  • 2 5773
  • 2 2639
  • 2.6322
  • 2.4818
  • 3.4196..*.

13

  • 1.0003 *

.9478

  • 1.0667 *

.8354

  • 7636 *.5323 *.4006 *

........... 6933

  • 2.4804
  • 3.3162.**4 9522 *
  • 2......................*.......
  • 2.4009
  • 2.5392..*.2.2997 14 *.8568 *.9810 *.8557 *

.8461 *.6265 *.4006 *

. 2. 7794

  • 2.4429
  • 7. 8259 + 2. 7558
  • 3.4225..*. 4.9522...*

15 *

.6790 *

.6137 *

.5687 *.4841

  • 3. 4 3 6 6
  • 3. 8041. *.4.13 7 9.*.4. 872 4
  • 14-SUS-Q AT 30% POWER, 4 EFPD, THIS IS LEVEL 17 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 BOTTOM)

H G

B A

......................F.........E.........D........C 8*

.9821

  • 1.3645
  • 1.2509
  • 1.4587
  • 1.3827
  • 1.4855
  • 1.2466 + 1.0796 *
  • 2.2300
  • 1.8324
  • 2.0364
  • 1 7597 + 1.8457
  • 1. 7086
  • 2. 0095..*.2.2886...*

9

  • 1.3645
  • 1.2488
  • 1.4480 1.3430
  • 1.4801 ' 1 4394
  • 1.4384 *.9061 *
  • 1. 8324
  • 1. 9775
  • 1.7950
  • 1.9098
  • 1.7236
  • 1. 7680
  • 1 7734
  • 2.7245.*

10

  • 1.2509
  • 1.4426 ' 1.2563 + 1.4298
  • 1.3794 ' 1.4662
  • 1.2938 *

.8697.*

  • 2. 0364..*.1. 8013.*. 2 0639.*.1.8204
  • 1. 8822
  • 1. 7749.*. 1. 9920.*.2. 8727
  • 11 ' 1.4587 ' 1.3420
  • 1.4244
  • 1.25'1
  • 1.3730 ' 1.2670
  • 1.3098 *

.7508 *

  • 1.7597
  • 1. 9125
  • 1. 0260
  • 1. 9854
  • 1. 7858 '.1 9204
  • 1.8887
  • 3.3511..*

12 ' 1.3827

  • 1.4823
  • 1.3784 + 1.3709 + 1.0335
  • 1.1824 *.9885 *
  • 1.8447
  • 1.7215 '.1.8847
  • 1.7681
  • 1. 8951
  • 1.7963
  • 2.3611
  • 13
  • 1.40:5
  • 1.4394
  • 1.4641
  • 1.2649
  • 1.1824 *.8504 *.6319 *
  • 1.70ta
  • 1.7680
  • 1.7764
  • 1. 9222..'. 1 7955..*. 2. 3616..*.3. 4540..*

.....e2.......................

14

  • 1.2466 ' 1.4362
  • 1.2916
  • 1.3088 *.9875 *.6319
  • 2.0095
  • 1 7757
  • 1. 9949
  • 1 0904
  • 2. 3625
  • 3. 4567
  • 15
  • 1.0796 *.9039 *.8606
  • 7497
  • 2.8768
  • 3 3565
  • M-svB-Q

APPENDIX Page 111 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1Dable 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 30% POWER, 4 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 TOP OF CORE, LEVEL 1 m BOTTOM)

H G

F E

D C

B A

8

  • 1.155'
  • 1.5562
  • 1.3773
  • 1.6268
  • 1.5090
  • 1.6879
  • 1.4116
  • 1.2756 *

................................................... 6 + 1.8745

  • 2.0449 +

2.2010

  • 1.7479
  • 1.9940
  • 1.6735
  • 1.7849
  • 1.589 9* 1.5562
  • 1.3977
  • 1.6100
  • 1.4651
  • 1.6890
  • 1.6333
  • 1.6772
  • 1.0335 *
  • 1. 7479
  • 1 9169
  • 1. 7203..*.1. 8645
  • 1. 6012
  • 1. 6493.+. 1 6110
  • 2. 5250
  • 10
  • 1.3773
  • 1.6044
  • 1.3634 + 1.6054
  • 1.5615
  • 1.6858
  • 1.5037 + 1.0142 *
  • 1. 9940
  • 1. 7267
  • 2. 0290
  • 1.7289
  • 1.7702
  • 1 6446
  • 1.8246
  • 2.6166
  • 11
  • 1.6260
  • 1.4598
  • 1.6001
  • 1.3955
  • 1.6236
  • 1.4887
  • 1.5936 *

.8868

  • 1.6735
  • 1.8661
  • 1.7353
  • 1.9101
  • 1.6516
  • 1.7841
  • 1.6791
  • 3.0428
  • 12
  • 1.5090
  • 1.6900
  • 1.5604
  • 1.6204
  • 1.3655
  • 1.5176
  • 1.2049 *

..................................... 1 7648

  • 1.6313
  • 2.1360
  • 1.7849
  • 1.5987
  • 1.7732
  • 1.6536 *

.7765

  • 13
  • 1.6879
  • 1.6333
  • 1.6836
  • 1.4865
  • 1.5176
  • 1.1031

................................ 1 6301

  • 2.1708
  • 3.1498
  • 1.6504 + 1.6465
  • 1.7864 *
  • 1.5896
  • 1.4116
  • 1.6740
  • 1.5015
  • 1.5926
  • 1.2038 *

.7754

  • 14 *

..................................... 2. 1371

  • 3.1521 1.0745
  • 1.6135
  • 1.0278
  • 1.6804
  • 15
  • 1.2756
  • 1.0314
  • 1.0121 *

.8846

  • 2.0449
  • 2.5326
  • 2.6215
  • 3.0473
  • M-SUB-Q AT 30% POWER, 4 EFPD, THIS IS LEVEL 15 0F 18 (LEVEL 18 : TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8

  • 1.2584
  • 1.6568
  • 1.4341
  • 1.7115
  • 1.5658
  • 1.7768
  • 1.4833
  • 1.3698
  • l 1.7124
  • 1.8440
  • 1.6179
  • 1.9094
  • 2.0386 *
  • 2. 3176
  • 1.8035
  • 2.0837 9* 1.6568
  • 1.4812
  • 1.6943
  • 1.5380
  • 1.8100
  • 1.7211
  • 1.8004
  • 1.0924 *
  • 2.5609 *

. 1. 8035

  • 2.0026
  • 1 7687
  • 1.9347
  • 1.6216
  • 1 6806
  • 1.6087 10
  • 1.4341
  • 1.6868
  • 1.4126
  • 1.7050
  • 1.6643 + 1.0089
  • 1.6151
  • 1.0849 *

............................ 1. 7501

  • 1.7983.*.1.6531..*.1. 8289
  • 2.6258 *
  • 2.0837
  • 1.77G1 2.1109
  • i 9575
  • 11
  • 1.7115
  • 1.5315
  • 1.6986
  • 1.4919
  • 1.7789
  • 1.6226
  • 1.7597 1.9690
  • 1.6561
  • 1.0050
  • 1.6670
  • 3.04B7 *

)

  • 1.7124
  • 1.9355
  • 1.7647
  • 12
  • 1.5658
  • 1.8078
  • 1.6622
  • 1.7757
  • 1.5707
  • 1.7425
  • 1.3355
  • 1.8 1.6300
  • 2.1419 *

...................... 014

  • 1.6554
  • 1.7863 *
  • 1.8440
  • 1.6197 *

)

13

  • 1.7768
  • 1.7190
  • 1.8068
  • 1.6215
  • 1.7436
  • 1.2681 *

.8654 *

................................................ 1865

  • 3.1797
  • 1.6179
  • 1.6813
  • 1.6551
  • 1.0073
  • 1 6293
  • 2.

1.6119

  • 1.7506
  • 1.3345 *

.8643

  • 14
  • 1.4833
  • 1.7971 *

............................... 677

  • 2.1441
  • 3.1821.*.

1.9094

  • 1.6117
  • 1.0313
  • 1.6 15
  • 1.3698
  • 1.0892
  • 1.0839 *

.9553

  • 2.0386
  • 2.5671
  • 2.6307
  • 3.0540
  • M-SUB-Q i

I

APPENDIX Page 112 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 2 (cont.)

F sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation.

f AT 30% POWER, 4 EFFD, THIS IS LEVEL 14 0F 18 (LEVEL.18 = TOP OF CORE, LEVEL 1 = BOTTOM)

......................F....**..E.........D........C.........B.........A......

H G

8

  • 1.2541 ' 1.6493
  • 1.4201
  • 1.7007 1.5497
  • 1.7650 *'1.4737
  • 1.3666 *
  • 2*.5614
  • 1.9705
  • 2.2723
  • 1. 8788
  • 2. 0289
  • 1 7731..*. 2.0898
  • 2 2175
  • 9
  • 1,6493
  • 1.4748
  • 1.6825
  • 1.5315
  • 1.8175
  • 1.7190 *.1.8025
  • 1.0871 *
  • 1. 9705
  • 2.2032
  • 1.9210.*.2. 1063
  • 1. 7731..*.1,8419..*. 1.7487.*.2. 7981..'*.

10

  • 1.4201
  • 1.6750
  • 1.4009
  • 1.7061
  • 1.6697
  • 1.8175
  • 1.6226
  • 1.0860 *
  • 2 2723.*. 1 9287
  • 2. 2939
  • 1. 8909
  • 1 9297
  • 1 7731
  • 1. 9689
  • 2. 8611..*

11

  • 1.7007
  • 1.5251
  • 1.6997
  • 1.5058
  • 1.8089
  • 1.6483
  • 1.7929 *.9660 *
  • 1. 8788
  • 2 1145..*. 1. 8976
  • 2. 1419
  • 1 7893..*. 1. 9529
  • 1 7909
  • 3 2559
  • 12
  • 1.5497
  • 1.8153
  • 1.6686
  • 1.8057
  • 1.6103
  • 1 7939
  • 1.3634 *

+

  • 2. 0289
  • 1. 7702.*.1.9313.*.1. 7922..*.1. 9455.*.1. 7668..*. 2.3230..*

13 ' 1.7650

  • 1.7179
  • 1.8153
  • 1.6461
  • 1.7950
  • 1.3077 *.8879 *
  • 1. 7731
  • 1.,8427..*.1. 7753.*. 1 9555..*.1.7665..*. 2.3873 + 3. 4740
  • 14
  • 1.4737 + 1.7993
  • 1.6194
  • 1.7907
  • 1.3623 *.8879 *
  • 2.0898
  • 1. 7515
  • 1.9716 '. 1 7924.'.2.3249 + 3. 4768
  • F 15
  • 1.3666
  • 1.0839
  • 1.0839 *.9639

.'... 175

  • 2.8072..*.2. 8668
  • 3 2631..*. M-SUB-Q 2.2...... *....

AT 30% POWER, 4 EFPD, THIS IS LEVEL 13 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

..G.........F.........E.........D........C.........B.........A......

H 8

  • 1.2606
  • 1.6761
  • 1.4309
  • 1.7286
  • 1.5637
  • 1.7918
  • 1.4887
  • 1.3944 *
  • 2 7934
  • 2. 1156
  • 2. 4684.*. 2 0373..*.2.2142
  • 1. 9197
  • 2.2692
  • 2.3787
  • 9
  • 1.6761
  • 1.4898
  • 1.7104
  • 1.5562 + 1.8593
  • 1.7489
  • 1.8421
  • 1.0999 *
  • 2. 1156
  • 2.3727
  • 2. 0730.*. 2 2763.*. 1.9025
  • 1.9993.*.1 8793..'. 3 0293 '

10

  • 1.4309
  • 1.7018
  • 1.4137
  • 1.7425
  • 1.7018
  • 1.0646
  • 1.6579
  • 1.1063 *
  • 2. 4684
  • 2.0827
  • 2.4936.*. 2 0292.*. 2.0732
  • 1.8951
  • 2.1139.*. 3.0847.*

11

  • 1.7286
  • 1.5487
  • 1.7339
  • 1.5358
  • 1.8625
  • 1.6900
  • 1.8539 *.9864 *
  • 2. 0 3 7 3. *.2. 2 8 F./
  • 2. 0 3 9 5
  • 2. 2 97 6
  • 1. 8 9 67
  • 2. 0 8 4 0
  • 1. 8 917
  • 3. 4 92 4
  • 12 + 1. 5 6 3 7 ' 1. 8571
  • 1. 6 9 97
  • 1. 8 5 9 3
  • 1. 6 6 8 6
  • 1. 85 9 3 ' 1. 4 052 *
  • 2. 2142..*.1.9041
  • 2.0762.*..1.9007
  • 2.1097
  • 1.8973..*. 2 4800.*

13

  • 1.7918
  • 1.7468
  • 1.8603
  • 1.6879
  • 1.8593
  • 1.3495 *.9136 *

. 1. 9197

  • 1.9993
  • 1. 8983.*. 2. 0869
  • 1. 8965..*. 2.5961..'.'3. 7695.*.

14

  • 1.4887
  • 1.8389
  • 1.6547 ' 1.8518
  • 1.4030 *.9136
  • I
  • 2. 2692
  • 1*.8826.*. 2 1170..*. 1. 8934.*. 2.4907
  • 3.7727
  • 15
  • 1.3944
  • 1.0967
  • 1.1042 *.9842
  • 2. 3787
  • 3.0377
  • 3 0890..*. 3.5008
  • M.SUB-Q t

.,._m-

l APPENDIX Page 113 of 140 McGuire 2 Cylce 10 Core Operating Limits Report' Table 2 (cont.)

' F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 30% POWER, 4 EFPD, THIS IS LEVEL 12 OF 18' (LEVEL 18 s TOP OF CORE, LEVEL 1 = BOTTOH)

.............G.........F.........E.......D.........C.........B.........A.....

H 8

  • 1.2306
  • 1.6440
  • 1.3937
  • 1.6986
  • 1.5315
  • 1.7586
  • 1.4576 + 1.3687 *

. 3. 1743

  • 2. 3925
  • 2. 8017
  • 2. 2555.*.2. 4560
  • 2.1234.*.2.5076
  • 2. 6159..*

9

  • 1.6440
  • 1.4576
  • 1.6793
  • 1.5272
  • 1.8314
  • 1.7157
  • 1.8121
  • 1.0764 * '
  • 2. 3925..*. 2.6896
  • 2.3433..*.2. 5759..*. 2. 1162.***2 2137
  • 2.0697
  • 3 3440.*

10

  • 1.3987
  • 1.6700
  • 1.3848
  • 1.7200
  • 1.6761
  • 1.8432
  • 1.6301 + 1.0860 *
  • 2.8017
  • 2.3545..*. 2.8268
  • 2.2796
  • 2. 3361..*.2.1249
  • 2.3653..*.3.3954..*

11

  • 1.6986
  • 1.5208
  • 1.7104
  • 1.5123
  • 1.8410
  • 1.6675
  • 1.8336
  • 9703 *

............ 5 8 3 8

  • 2. 2 914..+. 2. 5 8 65...*. 2.12 5 9. *. 2. *. 3 412.. *. 2. 115 8. *
  • 2.2555
  • 2......

12

  • 1.5315
  • 1.8293
  • 1.6718
  • 1.8378
  • 1.6504
  • 1.8421
  • 1.3869 *
  • 2. 4560
  • 2. 1142
  • 2. 3411..+. 2. 1300
  • 2. 3610
  • 2.1167
  • 2.7864
  • 13
  • 1.7586
  • 1.7136
  • 1.8389
  • 1.6654
  • 1.8432
  • 1.3334 *.9018 *

. 2 1234

  • 2. 2148..*. 2 1289..*.2. 3437
  • .2. 1157
  • 2 8991..*. 4. 2107
  • 14
  • 1.4576 + 1.8089
  • 1.6279
  • 1.8314
  • 1.3848 *.9018 *
  • 2.5076.*. 2.0736
  • 2.3691
  • 2. 1178
  • 2. 7897
  • 4.2147
  • 15
  • 1.3687
  • 1.0731
  • 1.0039
  • 9602
  • 2 6159
  • 3.3517
  • 3 4006
  • 3.9418
  • M-SUB-Q AT 30% POWER, 4 EFPD, THIS IS LEVEL 11 0F 18 (LEVEL 18 = 7CP OF CORE, LEVEL 1 = BOTTOM)

......................F.........E.........D.......C.......B.........A......

H G

B

  • 1.1856
  • 1.5894
  • 1.3516 + 1.6451
  • 1.4001
  • 1.7007
  • 1.4073
  • 1.3227 *
  • 3. 6840.*. 2 7561..*.3 2269
  • 2 5061
  • 2 7323.*. 2. 3616
  • 2 7927
  • 2. 9046.*.

9

  • 1.5894
  • 1.4073
  • 1.6258
  • 1.4780
  • 1.7757
  • 1.6590
  • 1.7543
  • 1.0378 *
  • 2. 7561..*. 3. 1089..*. 2. 6283..*. 2. 8725..*. 2. 3503
  • 2. 4656..*. 2. 2977'* 3. 7212..*.

10

  • 1. 3 516
  • 1. 617 2
  • 1. 3 3 9 8
  • 1. 6 6 97
  • 1. 62 2 6
  • 1. 7 8 9 6
  • 1. L77 6
  • 1. 04 8 5 *
  • 3. 2269
  • 2 6409..*. 3. 2001..*. 2. 5688
  • 2. 6567
  • 2.3742
  • 2.6221..*. 3 7624
  • 11
  • 1.6451
  • 1.4716
  • 1.6600
  • 1.4673
  • 1.7886
  • 1.6172'* 1.7789
  • 9382 *
  • 2 5061.*.2. 8781..*. 2.5777
  • 2.9959
  • 2. 4587
  • 2.7136
  • 2.4455..*.4.4032
  • 12
  • 1.4801
  • 1.7736
  • 1.6194
  • 1.7854
  • 1.6011
  • 1.7907
  • 1.3430 *
  • 2.7323
  • 2.3478.*.2.6599..*. 2.4630
  • 2 7336.*. 2. 4440
  • 3.2278
  • 13
  • 1.7)07 a 1.6568 ' 1.7864
  • 1.6140
  • 1.7918
  • 1.2927 *.8739 *
  • 2.3616..*. 2. 4670..*. 2. 37(8
  • J 7169..*. 2 4427
  • 3. 3550..*. 4 8717
  • 14
  • 1.4073 + 1.7511 + 1.5744
  • 1.7779
  • 1.3409 *.8729 *
  • 2. 7927
  • 2. 3013
  • 2 6260..*.2. 4482.*. 3.2323.*.4.8766..*.

15

  • 1.3227
  • 1.0357 + 1.0474
  • 9361
  • 3 7307
  • 3.7656
  • 4.4120
  • M-SUB-Q f

b

,x

-a w

-m---v r--

--w-

--r--

-,ew,-

APPENDIX Page 114 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1rable 2 (cont.)

F-sub-Q/M-sub-Q Valm (F.sub-Q OP Margin) - Power Escalation AT 30% POWER, 4 EFPD, THIS IS LEVEL 10 0F 18 (LEVEL 18 = TOP 07 CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

1.3238

  • 1.6204
  • 1.4501
  • 1.6718
  • 1.3784
  • 1.3023
  • 8* 1.1578
  • 1.5647 3.9296
  • 2.9316
  • 3.4484
  • 2.7272
  • 2.9951
  • 2.5762
  • 3.0510
  • 3.1376
  • 9
  • 1.5647
  • 1.3794
  • 1.6022
  • 1.4523
  • 1.7511
  • 1.6268
  • 1.7286
  • 1.0164 *
  • 2. 9316
  • 3.3140
  • 2.8540
  • 3.1398
  • 2.5598
  • 2.6973
  • 2.4962..*. 4.0484
  • 10
  • 1.3238
  • 1.5936
  • 1.3130
  • 1.6461
  • 1.5936
  • 1.7671
  • 1.5500
  • 1.0303
  • 3.4484
  • 2.8688
  • 3.4810
  • 2.7962
  • 2.8894
  • 2.5853
  • 2.8595
  • 4.0934
  • 11 + 1.6204
  • 1.4459
  • 1.6365
  • 1.4394
  • 1.7661
  • 1.5894
  • 1.7586 *

.9200 *

  • 2.7272
  • 3.1443
  • 2.8087
  • 3.1966 2.6205
  • 2.9065
  • 2.6346
  • 4.8052
  • 1.7489
  • 1.5904
  • 1.7618
  • 1.5754
  • 1.7693
  • 1.3216
  • 12
  • 1.4501

............ 5569

  • 2.8951
  • 2.6252..*. 2.9433***.2.6268.*. 3.5003 *
  • 2.9951
  • 2 1.7629
  • 1.5872
  • 1.7704
  • 1.2702 *

.8568

  • 13
  • 1.6718
  • 1.6247
  • 2.5762
  • 2.6989
  • 2 5883
  • 2 9104
  • 2.6252
  • 3.6536
  • 5.3651..*.

14

  • 1.3784
  • 1.7254
  • 1.5487
  • 1.7564
  • 1.3195 *

.8557 *

  • 3.0510
  • 2.5005
  • 2.0651
  • 2.6377
  • 3.5030
  • 5. 3716
  • 15
  • 1.3023
  • 1.0142
  • 1.0282 *

.9170

  • 4.0595
  • 4.0972
  • 4.8157
  • M-SUB-Q AT 30% POWER, 4 EFPD, THIS IS LEVEL 9 0F 18 (LEVEL 18 = TOP OF COPE, LEVEL 1 = BOTTOM)

H G

F E

D A

.................................................C........B B

  • 1.0967
  • 1.4833
  • 1.2552
  • 1.5380
  • 1.3762
  • 1.5840
  • 1.3055
  • 1.2316 *

.... 189.*. 2 9972

  • 3.4837
  • 2.6648
  • 2.9250
  • 2. 5276
  • 3.0156
  • 3 1623 *
  • 4.0 9
  • 1.4833
  • 1.3077
  • 1.5197
  • 1.3773
  • 1.6611
  • 1.5401
  • 1.6376 *.9618 *
  • 2.9972
  • 3.3850
  • 2. 7839
  • 3.0594
  • 2.5104
  • 2.6536 + 2.4794
  • 4.0558
  • 10
  • 1.2552
  • 1.5112
  • 1.2456
  • 1.5637
  • 1.5112
  • 1.6772 + 1.4694 *

.9746 *

  • 3.4837
  • 2.7980
  • 3 4111
  • 2.7374
  • 2.8595
  • 2. 5480
  • 2.8540
  • 4.1355
  • 11
  • 1.5380
  • 1.3709
  • 1.5540
  • 1.3677
  • 1.6761
  • 1.5000
  • 1.6675 *

.8707 *

  • 2.6648
  • 3.0636
  • 2 7493
  • 3.2602
  • 2.6728
  • 2.9690
  • 2.6923..*. 4.8957
  • 12
  • 1.3762
  • 1.6590
  • 1.5069
  • 1.6729
  • 1.4940
  • 1.6804
  • 1.2509 *
  • 2.9258.*. 2 5076
  • 2.8632..*.2 6193.*. 3 0053
  • 2. 6809
  • 3. 5796 *
  • 1.2038 *.8107
  • 1.5840
  • 1.5300
  • 1.6740
  • 1.5048
  • 1.6804 13 ** 2 5276
  • 2.6552
  • 2.5510
  • 2.9730
  • 2.6793
  • 3.7330 *.5.4917
  • 14
  • 1.3055
  • 1.6343
  • 1.4673
  • 1.6654
  • 1.2499 *.8107
  • J
  • 3.0156
  • 2.4836
  • 2. 8595
  • 2.6956
  • 3.5854
  • 5.4985
  • 15
  • 1.2316 *

.9505 *

.9725 *

.8697

  • 4.9066
  • M-SUB-Q
  • 3.1623
  • 4.0707

APPENDIX Page 115 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1Dable 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 30% POWER, 4 EFPD, THIS IS LEVEL 8 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

F G

F E

D C

B A

8

  • 1.0646
  • 1.4544 ' 1.2231
  • 1.5069
  • 1.3398
  • 1.5487
  • 1.2702
  • 1.2070
  • 3.9192
  • 2.8669
  • 3.2942
  • 2.5161
  • 2.7839
  • 2.3909
  • 2.8688
  • 2.9730 *

.9361 9

  • 1.4544
  • 1.2756
  • 1.4898
  • 1.3452
  • 1.6290
  • 1.5026
  • 1.6054
  • 2.8669
  • 3.2602
  • 2.6205
  • 2.9008
  • 2.3730 '.2. 5176
  • 2.3391
  • 3.8442..*

1.2134

  • 1.5326
  • 1.4748 ' 1.6461
  • 1.4373 *

.9510

  • 10
  • 1.2231
  • 1.4P23 *

................. 5808

  • 2.7072
  • 2.4026
  • 2. 7006
  • 3.9157
  • 3.2316
  • 2
  • 3.2942
  • 2. 6346
  • 1.5069
  • 1.3388
  • 1.5230
  • 1.3334
  • 1.6451
  • 1.4737
  • 1.6386 *

.8493

  • 11 '* 2.5161
  • 2.9065
  • 2.5929
  • 3.1805
  • 2.5974
  • 2.8970 2.6051
  • 4.6535
  • 12
  • 1.3398
  • 1.6268
  • 1.4716
  • 1.6418
  • 1.4608
  • 1.6504
  • 1.2231
  • 3.5030 *
  • 2.7839
  • 2. 3704
  • 2.7122
  • 2.6020
  • 2.9670
  • 2.6346
  • 13 ' 1.5487
  • 1.5005
  • 1.6429
  • 1.4705
  • 1.6504
  • 1.1749 *

.7904 *

.... 909 '.2.5190

  • 2.4065..*.2.9009..*.2.6330
  • 3.6994
  • 5.3978 *
  • 2.3 14
  • 1.2702
  • 1.6022
  • 1.4341
  • 1.6365
  • 1.2220 *.7893 '
  • 2.8688
  • 2.3440 '.2.7072
  • 2.6082
  • 3.5086
  • 5.4044
  • 15
  • 1.2070 *

.9328 *

.9500 *

.8472

  • 2.9730
  • 3.8543
  • 3.9227
  • 4.6633
  • M-SUB-Q l

4 AT 30% F0WER, 4 EFPD, THIS IS LEVEL 7 CF 10 (LEVEL 18 = TOP CF CORE, LEVEL 1 : BOTTOM) l H

G F

E D

C B

A 1.1706

  • 1.4437
  • 1.2809
  • 1.4812
  • 1.211,
  • 1.1535
  • 8* 1.0174
  • 1.3944 *

..................'.............................................. 2.7409..*.

3.6657

  • 2.6393 3.0200
  • 2.3194
  • 2.5747
  • 2.2115
  • 2.6504
  • 1.5358 *

.8921

  • 9* 1.3944
  • 1.2209
  • 1.4287
  • 1.2863
  • 1.5604
  • 1.4351 2.1607 + 3.5537 *
  • 2.1918
  • 2.3317
  • 2.6393 '.3.0135 * 'i.4118 '.2.6777 10
  • 1.1706
  • 1.4212 ' 1.1610
  • 1.4683
  • 1.4094
  • 1.5776 + 1.3730 *

.9071

  • 3.0200
  • 2.4250
  • 2.9770
  • 2.3819
  • 2.5104 2.2226
  • 2.5005
  • 3.6118
  • 1.4437
  • 1.2798
  • 1.4598
  • 1.2756
  • 1.5765
  • 1.4084
  • 1.5690 *.0097
  • 11

....................................... 4210

  • 2.7072
  • 2.4197
  • 4.2921
  • 2.3194
  • 2.6642
  • 2.3935
  • 2.9670
  • 2.

12

  • 1.2009
  • 1.5583
  • 1.4062 ' 1.5733
  • 1.3966
  • 1.5808
  • 1.1685 *
  • 2.5747
  • 2.1896
  • 2.5133
  • 2.4264
  • 2.8051
  • 2.4684
  • 3.2795
  • 13 ' 1.4612
  • 1.4330
  • 1.5744
  • 1.4062
  • 1.5819
  • 1.1213 *

.7529 *

  • 2.2115 '.2.3329
  • 2.2260
  • 2.7105
  • 2.4684
  • 3.4755
  • 5.0582
  • 14
  • 1.2113
  • 1.5337
  • 1.3698 ' 1.5679
  • 1.1663 *

.7518 *

  • 2.6504
  • 2.1650
  • 2.5061
  • 2.4224
  • 3.2844
  • 5.0640
  • 15 ' 1.1535 *

.8809 *

.9061 *

.8075

  • 2.7408
  • 3.5652
  • 3.6177
  • 4.3004
  • M-SUB-Q

APPENDIX Page 116 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 30% POWER, 4 EFPD, THIS IS LEVEL 6 OF 18 (LEVEL 18 = TOP OF CORE. LEVEL 1 s BOTTOM)

....H........G........F........E....................................A......

D C

B 8*

.9596

  • 1.3152
  • 1.1042 + 1.3602
  • 1.2059
  • 1.3902
  • 1.1363
  • 1.0785 *

................**.............. 77

  • 2.4224
  • 2.0833.*.2 5047
  • 2.6036
  • 3.3773
  • 2.4506
  • 2.8212
  • 2.17 9*

1.3152

  • 1.1535
  • 1.3462
  • 1.2102
  • 1.4662
  • 1.3452
  • 1.4394 *

.8343 *

  • 2.4506
  • 2.8033
  • 2.2555
  • 2.5090
  • 2.0629.*. 2. 1994
  • 2 0401..*. 3 3747
  • 10
  • 1.1042
  • 1.3388
  • 1.0946
  • 1.3816
  • 1.3227
  • 1.4812
  • 1.2863 *

.8482

  • 2.8212
  • 2.2683
  • 2.7821
  • 2.2305
  • 2.3540
  • 2.0853
  • 2.3540
  • 3.4217
  • 11
  • 1.3602
  • 1.2038
  • 1.3730
  • 1.2006
  • 1.4812
  • 1.3216
  • 1.4694 *

.7572 *

.............................................. 2.5204

  • 2.2509
  • 4.0447
  • 2.1777
  • 2.5147
  • 2.2407
  • 2.7561
  • 2.2486
  • 1.3195
  • 1.4769
  • 1.3098
  • 1.4833
  • 1.0924
  • 12
  • 1.2059
  • 1.4641 *

................... 2. 3578

  • 2 2544
  • 2.5974
  • 2.2965
  • 3.0658 *
  • 2.4224
  • 2.0610
  • 13
  • 1.3902
  • 1.3441
  • 1.4700
  • 1.3184
  • 1.4833 + 1.0496 *

.7036 *

........................ 3.2506

  • 4.7405 *
  • 2.2953 *
  • 2.0833
  • 2.2005
  • 2 0883
  • 2.5247 14
  • 1.1363
  • 1.4373
  • 1.2841
  • 1.4673
  • 1.0913 *

.7026 *

...................... 590

  • 2.2544
  • 3.0700
  • 4.7536
  • 2.5047
  • 2.0438
  • 2.3 15
  • 1.0785 *

.8322 *

.8472 *

.7561

................... 3.4270

  • 4.0521.*. M-SUB-Q
  • 2.6036
  • 3.3824
  • AT 30% ?OWER, 4 EFPD, THIS IS LEVEL 5 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H C

F E

D C

B A

8*

.9275

  • 1.2820
  • 1.0710
  • 1.3205
  • 1.1642
  • 1.3441
  • 1.0913
  • 1.0410
  • 3.032
  • 2.2452
  • 1.9246
  • 2.3341
  • 2.4210 *

...... 1.*.2.1961

  • 2 5732
  • 2. 0004 9
  • 1.2820
  • 1.1192
  • 1.3109
  • 1.1706
  • 1.4180
  • 1.2959
  • 1.3912 *

.8011 *

  • 2.1961
  • 2.5104
  • 2.0591
  • 2. 3097
  • 1 9031
  • 2.0372
  • 1.8860
  • 3.1555
  • 10
  • 1.0710
  • 1.3034
  • 1.0592
  • 1.3377
  • 1.2734
  • 1.4319
  • 1.2381 *

.8150 *

  • 2.5732
  • 2.0697
  • 2.5495
  • 2.0420
  • 2.1550
  • 1.9154
  • 2.1756
  • 3.1805
  • l I

11

  • 1.3205
  • 1.1642
  • 1.3291
  • 1.1578
  • 1.4309
  • 1.2702
  • 1.4180 *

.7251 *

  • 2.0004
  • 2. 3158.*. 2.0514
  • 2. 4780
  • 2.0186
  • 2.2706
  • 2.0344
  • 3.7496
  • I 12
  • 1.1642
  • 1.4159
  • 1.2702
  • 1.4276
  • 1.2595
  • 1.4309
  • 1.0485 *
  • 2.2452
  • 1 9014
  • 2 1681..*.2.0233
  • 2 3540
  • 2.0755
  • 2.7752
  • 13
  • 1.3441
  • 1.2938
  • 1.4287
  • 1.2681
  • 1.4319
  • 1.0057 *

.6737 *

  • 1.9246
  • 2.0382
  • 1.9179
  • 2. 2729
  • 2.0755
  • 2.9690..*. 4.3384
  • 1.0913
  • 1.3800
  • 1.2349
  • 1.4159
  • 1.0474 *

.6726

  • 14 ** 2.3341
  • 1.8892
  • 2 1799
  • 2.0372
  • 2.7786
  • 4.3427 I

15

  • 1.0410 *

.7979 *

.8140 *

.7240

  • 2.4210
  • 3 1645
  • 3.1873
  • 3.7560
  • M-SUB-Q 1

1 l

m.

f

\\

APPENDIX -

Page 117 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1hable 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin)- Power Escalation AT 30% POWER, 4 EFPD, THIS IS LEVEL 4 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTUM1-H G

F E

D C

B A

8'

.8729

  • 1.2027
  • 1.0078
  • 1.2338
  • 1.0892 ' 1.2499
  • 1.0121
  • 9564
  • 2 8744
  • 2. 0726.*. 2.4304
  • 1. 9339
  • 2 1692.*. 1. 8748
  • 2.2870
  • 2. 3907
  • 9
  • 1.2027
  • 1.0528
  • 1.2274
  • 1.0924
  • 1.3141
  • 1.2006
  • 1.2820
  • 7379 *
2. 0726.*.2 3730.*.1 9745..*.2. 2204.*.1. 8520
  • 1 9860 '. 1. 8505
  • 3 1133 *

.10

  • 1.0078
  • 1.2209 *.9950
  • 1.2434 + 1.1802
  • 1.3227
  • 1.1417
  • 7497
  • 1 2.4304 + 1.9851..*. 2 4357 + 1.9648.*.2. 0892.*.1 8567
  • 2 1223
  • 3 1331...*

11

  • 1.2338
  • 1.0871 ' 1.2370
  • 1.0785 ' 1.3216
  • 1.1738 ' 1.3002
  • 6662
  • 1 9339
  • 2. 2260.*. 1. 9745
  • 2.3679.*. 1 9449.*. 2. 1918
  • 1. 9666
  • 3.6627 *

[

12

  • 1.0892
  • 1.3130
  • 1.1770.* 1.3195
  • 1.1642 ' 1.3173
  • 9618
  • 2.1692..*.1 8513.*.2.0922.*.1. 9501
  • 2 2373 '.1.9851
  • 2.6907.*

13

  • 1.2499
  • 1.1984
  • 1.3195
  • 1.1717
  • 1.3173 *.9243 *.6169 *
1. 8748..*.1 9869.*. 1 8598
  • 2.1950.'. 1.9842..*. 2 8302
  • 4.1824
  • 14 + 1.0121
  • 1.2798
  • 1.1395
  • 1.2991 *.9607 *.6169 '

2.2870

  • 1 8536
  • 2.1264.*.1 9683.*.2. 6940.***4.1824
  • 15 *.9564 *.7358 *

.7486 *.6651

2. 3987
  • 3 1221..*.3.1376.*.3. 6718
  • M-SUB-Q AT 30% POWER, 4 EFPD. THIS IS LEVEL 3 OF 18 (LEVEL 18 = TOP OF '9RE, LEVEL 1. BOTTOM)

H C

F E

D C

B A

8*

.8354

  • 1.1492 *

.9671

  • 1.1749
  • 1.0378
  • 1.1770
  • 9436
  • 8814 *
2. 6809
  • 1.9544
  • 2.2942
  • 1.8661.*. 2.0952
  • 1.0336..*.2.2671
  • 2.4092
  • 9
  • 1.1492
  • 1.0078
  • 1.1760
  • 1.0432
  • 1.2338
  • 1.1256
  • 1.1910 *.6844
  • 1.9544
  • 2. 2238
  • 1.8836
  • 2.1274 + 1. 0052..*.1. 9475..*.1. 8328
  • 3 1111..*.

10 *.9671

  • 1.1685 *.9543
  • 1.1813
  • 1.1085
  • 1.2349
  • 1.0603
  • 6929
  • 2 2942..*.1. 8941..*. 2. 3158
  • 1. 8868
  • 2 0196
  • 1. 8074
  • 2. 0892..*. 3 1221
  • 11
  • 1.1749
  • 1.0378
  • 1.1760
  • 1.0217
  • 1.2349
  • 1.0935
  • 1.1963
  • 6115 *
1. 8661
  • 2. 1326
  • 1.8957
  • 2.2361.*. 1.8661
  • 2.1062
  • 1 9238
  • 3.6415
  • 12
  • 1.0378
  • 1-.2316
  • 1.1074
  • 1.2316
  • 1.0860
  • 1.2209
  • a857
  • 2 0952
  • 1. 0074
  • 2. 0223
  • 1 8701.*. 2.1681
  • 1.9373
  • 2.6299.*.

13

  • 1.1770
  • 1.1235
  • 1.2316
  • 1.0913
  • 1.2220 *.8525
  • 5666 *
  • 2.7962
  • 4.1355
  • 1.8336
  • 1.9404
  • 1.8103
  • 2.1092 '.1.936#

14 *.9436

  • 1 1888
  • 1.0581
  • 1.1952 *.8846 *.5666 *
2. 2671..'.1.8359
  • 2.0942
  • 1.9263..*.2.6330
  • 4.1394
  • 15 *

,8814 *.6822 *.6919 *.6105

  • 3 6475..*. M-SUB-Q A

3 s~-

e 9--um (em--um w

e m

wwe,g e

+w-

+hei-w-eeme*-er=

+6

-w

APPENDIX i

Page 118 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1Dable 2 (cont.)

F-sub-Q/M-sub-Q Values (F-sub-Q OP Margin) - Power Escalation AT 30% POWER, 4 EFPD, THIS IS LEVEL 2 OF 18 (LEVEL 18. TOP OF CORE, LEVEL 1 m BOTTOM)

H G

C B

A

......................F.........E.........D.................................

.8129 *

.7283

  • 8*

.7604

  • 1.0292 *.8771
  • 1.0571 *

.9382

  • 1.0217
  • 2 7374
  • 2.0214
  • 2. 3515
  • 1. 9509
  • 2 1788
  • 1. 9905.*. 2.4950
  • 2. 7493 *

.9810

  • 1.0142 *

.5858

  • 9
  • 1.0292 *

.9050

  • 1.0603 *.9510
  • 1.0817
  • 2.0214
  • 2.2953
  • 1. 9518
  • 2.1853..*. 1 9171..*. 2.1022
  • 2.0223.*. 3 4323..*.

10 *

.8771

  • 1.0549 *

.8729

  • 1.0539 *

.9768

  • 1.0721 *

.9061 *

.5837 *

. 2.3515

  • 1.9622
  • 2.3679
  • 1. 9762
  • 2 1315
  • 1.9432
  • 2.2858.*.3. 4837 *

.9457 + 1.0485 *

.9189

  • 1.0774 *

.9489 *

.9917 *

.5109

  • 1.0571
  • 11
  • 1.9851
  • 2.3049
  • 1.9906
  • 2.2532
  • 2.1544
  • 4.0670 *
  • 1 9509
  • 2.1907

.9382

  • 1.0796 *

.9757

  • 1.0742 *

.9460

  • 1.0367 *

.7454

  • 12 *

............................ 2. 0040

  • 2.2776
  • 2.0912..*.2.8875 *
  • 2.1346
  • 2.1788
  • 1.9204

.7272 *

.4766 *

.9800

  • 1.0699 *

.9468

  • 1.0367 13
  • 1.0217 1

1.9905

  • 2.1042
  • 1.9458
  • 2.2578
  • 2.0902
  • 2.9911
  • 4.5111
  • 14 *

.8129

  • 1.0121 *

.9050 *

.9907 *

.7443 *

.4766 *

  • 2.4850
  • 2. 0260
  • 2.2906
  • 2.1565
  • 2.8913
  • 4.5111
  • 15 *

.7283 *

.5837 *

.5826 *

.5090

  • 2.7493
  • 3.4403
  • 3.4892
  • 4.0707
  • M-SUB-Q AT 30% POWER, 4 EFPD, THIS IS LEVEL 1 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 : BOTTOM)

H G

P E

C B

A

........................................D.................................

8*

.5419

  • 7154 *

.5858 *

.7551 *

.6362 *

.6447 *.5200 *

.4252

  • 3.6445
  • 2.7561
  • 3.3517
  • 2.5990
  • 3.0743
  • 3.0156
  • 3.6748
  • 4.5019
  • 9*

.7154 *.5933 *

.7368 *

.6608 *

.7615 *

.6169 *

.6458 *

.3748

  • l

............................ 2 9810.*. 2.5944

  • 3.1850
  • 3.0342.*.5.1286 *
  • 2.7561
  • 3.3140
  • 2.6728
  • 10 *

.5858 *

.7347 *

.5998 *

.7518 *

.6415 *

.7358 *

.5601 *

.3599 *

..... 17

  • 2.6793
  • 3,2942.*. 2.6425.*. 3 0893
  • 2.7022
  • 3.5170
  • 5 3978 *
  • 3.35 11 *

.7551 *

.6576 *

.7465 *.6115 *

.7422 *

.6040 *

.5998 *

.3149 *

  • 2.5990
  • 2.9891
  • 2.6583
  • 3.2698
  • 2. 7272
  • 3.3517
  • 3.3593
  • 6.2618
  • 12 *

.6362 *

.7593 *

.6394 *

.7390 *

.6083 *

.6565 *

.4573 *

  • 3.0743
  • 2.5990
  • 3.1002
  • 2.7374
  • 3.3593
  • 3.1265
  • 4.4610
  • 13 *

.6447 *

.6158 *

.7347 *

.6030 *

.6565 *

.4648 *

.2977 *

  • 3.0156
  • 3.1873
  • 2. 072
  • 3.3567
  • 3.1265
  • 4.4253
  • 6.8328
  • 14 *

.5280 *

.6447 *.5591 *

.5987 *

.4562 *

.2977

  • 3.6748
  • 3.0384
  • 3.5226
  • 3.3644
  • 4.4655
  • 6.8328
  • 15 *

.4252 *

.3748 *

.3588 *

.3149

  • P-SUB-Q 4.5019
  • 5.1345
  • 5.4044
  • 6.2707 *

..................................... M-SUB-Q l

I

nr APPENDIX

Page 119 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1

l' Table 3

. M-sub-C Values (F-sub-Q RPS Margin) - Normal Operations THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 e BOTTOM) t

....H........G........F.........E.........D**......C.........B.........A......

8

  • 2.5976
  • 2.0937
  • 2.4631
  • 2.0378
  • 2.3304
  • 2.3590
  • 2.6947
  • 3.2335 *
  • 2.4325
  • 2.0495
  • 2.2796
  • 1.9036
  • 2.1227
  • 2.1610
  • 2.4498
  • 2.8149 *
  • 2. 2 2 3 2.. *.1.

9 2 3 9. *. 2. 16 6 7.. *. 1 8. 3 3 9.. *. 2. 0 2 7 7.. *.2.

0 5 5 4.. *. 2. 2 915.. +. 2. 5 4 6 9..

  • 9
  • 2.0937
  • 2.4438 + 2.0727
  • 2.3086
  • 2.0427
  • 2.4308
  • 2.3357
  • 3.5902 *
  • 5.0495
  • 2.'3273
  • 1.952$
  • 2.1098
  • 1.9176
  • 2.2548
  • 2.1640
  • 3.1700 *
  • 1

... 9239..*. 2. 1734. 1. 8679.*.2. 0133 *.1. 8458..* 2. 1394.*.2.0435..*. 2. 8822..*..

10

  • 2.4631 + 2.0741
  • 2 4377
  • 2.0449
  • 2.3658
  • 2.1089
  • 2.6520
  • 3.7775 *
  • 2.2796
  • 1.9549
  • 2.2516
  • 1.9537
  • 2.2226
  • 2.0367
  • 2.4869
  • 3.3292 *
  • 2. 16 6 7...*.1.

8 7 2 4...*. 2. 12 8 4.. *. 1 8 6 7 9.. *. 2. 10 7 0.. *.1.

9 4 2 5.. *. 2. 3 2 3 6. *. 2. 9 613.. *..

{

11

  • 2.0378
  • 2,3103
  • 2.0511
  • 2,42Pt
  • 2.0742 + 2.4848
  • 2.5083
  • 4.2406 *
  • 1.9036
  • 2.1112 + 1.9586
  • 2.3188
  • 2.0340
  • 2.3934
  • 2.4315
  • 3.8806 *
  • 1 8339..*.2. 0146..*. 1. 8735..*. 2. 1661.'*.1 8973..*.2. 2229..*.2. 2383..*. 3. 4046
  • e..

12

  • 2.3304
  • 2.0440
  • 2.3694
  • 2.0770
  • 2.4374
  • 2.2797
  • 3.0821 *
  • 2.1227
  • 1.9176
  • 2.2250
  • 2.0342
  • 2.2803
  • 2.1788
  • 2.9523 *
  • 2. 0 2 7 7.. +..1. 8 4 5 8.. *.2.

10 8 4...*.1.

8 97 3.. *. 2. 0 6 8 0.. *.1 9 9 3 9. *.2.

6 7 2 3.. *.

13

  • 2.3590
  • 2.4327
  • 2.1104
  • 2.4868
  • 2.2790
  • 3.0049
  • 4.3149 *
  • 2.1610
  • 2.2548
  • 2.0300
  • 2.3936
  • 2.1788
  • 2.8201
  • 3.9096 *
  • 2. 0 5 5 4. *. 2. 13 9 4., +* 1. 9 4 2 5.. *. 2. 2 2 4 2.. *.1.9 9 3 7.. *. 2. 5 3 57.. *. 3. 310 9. *.

14

  • 2.6947
  • 2.3375
  • 2.6542
  • 2.5095
  • 3.0833
  • 4.3149 *
  • 2.4498
  • 2.1655
  • 2.4889
  • 2.4315
  • 2.9523
  • 3.9099 *
  • 2. 2915..*. 2. 0449.***2. 3236...*.2. 2383.*.2. 6723.*.3. 3109..*

15

  • 3,2335
  • 3.5944
  • 3.7775
  • 4.2441
  • 2.8149
  • 3.1733
  • 3.3328
  • 3.8806
  • 200 EFPD 118 % POWER

. 2. 5469

  • 2. 8848..*.2. 9619..*.3. 4046..* 405 EFPD 118 4 POWER THIS IS LEVEL 17 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

....H.........G

....e**e...E.........D.........C.....ee.B.....ee..A....e F

8

  • 1.9902
  • 1.6345
  • 1.8209
  • 1.6394
  • 1.7465
  • 1.6504
  • 1.9077
  • 2.1097
  • 1.9180
  • 1.6027
  • 1.7487
  • 1.5171
  • 1.6289
  • 1.5980
  • 1.8212 + 1.9586 *
  • 1. 9093..*. 1 59.44 1.7646
  • 1 5107
  • 1. 6584..+. 1. 6489.*.1. 8533..*. 1 9316..*.

9

  • 1.6345
  • 1.7718
  • 1.6246
  • 1.7724
  • 1.6086
  • 1.6836
  • 1.6673
  • 2.5288
  • 1 6027
  • 1.7348
  • 1.5268
  • 1.6505.* 1.5223.* 1.6306
  • 1.6054
  • 2.3751 *

. 1. 5944.*.1 7550

  • 1 5344.*. 1. 6706..*.1. 5198..*.1. 6738.***1 6241..+.2.3350.*
  • e 10
  • 1.8209
  • 1.62'94
  • 1.8453
  • 1.6334
  • 1.7058
  • 1.6127
  • 1.8101
  • 2.5820 *
  • 1.7487
  • 1.5305
  • 1 7141 t.5434
  • 1.6558
  • 1.5534
  • 1.7736
  • 2.4007 *

~l

  • 1. 7646..*.1. 5373.*.1. 7169.* 1.5541..*.1.,.6778..*. 1 5734...*.1 7.959.*. 2. 3041..*
    • e 11
  • 1.6394
  • 1.7770
  • 1.6369
  • 1.7846
  • 1.6117
  • 1.7425
  • 1.6899
  • 2.8761
  • 1.5457
  • 1.1350
  • 1.5761
  • 1.7472
  • 1.7366
  • 2.8099 *
  • 1.5171
  • 1.6514

..1 5107

  • 1. 6713..*. 1 5556..*.1. 7364...*.1. 5645..*.1 7683.*. 1. 7437
  • 2 6728..*.

12

  • 1.7465
  • 1.6091
  • 1.7061
  • 1.6134
  • 1.7240
  • 1.6109
  • 2.0964 *
  • 1.6289 + 1.5216
  • 1.6575
  • 1.5777
  • 1.7001
  • 1.5987
  • 2.1317 *

.** 1 5196...*.1. 6787

  • 1. 5646.*. 1. 7051..*.1. 5975..*.2. 1062..*.
  • 1 6584 13
  • 1.6504
  • 1.6842
  • 1.6139
  • 1.7438
  • 1.6180
  • 2.1063
  • 2.9614 *
  • 1.5980
  • 1.6306
  • 1.5542
  • 1.7482
  • 1.5918
  • 2.0901
  • 2.8280 *

. 1. 6 4 8 9.. *. 1. 6 7 3 8. *. 1. 5 7 41. *.1.

7 6 8 3. *.1 5 5 t 8..*. 2. 019 3.. *. 2. 5 9 9 8..

  • j 14
  • 1.9077
  • 1.6688
  • 1.8112
  • 1.6909
  • 2.0964
  • 2.9642 *
  • 1.8212
  • 1.6063 + 1.7746
  • 1.7375
  • 2.1318
  • 2.8280 *
  • 1. 8533..*. 1 624.1..*.1 7959..*.1 7437..*. 2. 1062..*.2. 6002..*

15

  • 2.1097
  • 2.5319
  • 2.5655
  • 2.8834
  • 1.9586
  • 2.3787
  • 2.4026
  • 2.8124
  • 200 EFPD 118 % POWER
  • 1. 9316..*. 2. 3381.*.2. 3058
  • 2. 6728..*. 405 EFPD 118 % POWER I

i

.,,,,_w.

~.

..e

3.. -,,., -,.,,

..,e,

...m-,-,.,. -., -

-y=,.

e,

APPENDIX Page 120 of 140 ~

McGuire 2 Cylce 10 Core Operating Limits Report Table 3 (cont.)

M sub C Values (F-sub-Q RPS Margin) - Normal Operations THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

.........................................................e+.............*

8

  • 1.8989
  • 1.5107
  • 1.7285
  • 1.5101
  • 1.6396
  • 1.4777
  • 1.7183
  • 1.8267 *
  • 1.8216
  • 1.4666
  • 1.6496
  • 1.3850
  • 1.5208
  • 1.4637
  • 1.6954
  • 1.7655 *
  • 1. 8435.* 1.4932..*. 1. 6802.*.1 3994.*. 1. 5745
  • 1 5509.*.1. 7672..*.1 79.16..*

9

  • 1.5107
  • 1.6651
  • 1.5081
  • 1.6674
  • 1.4432
  • 1.5160
  • 1.4613
  • 2.2715 *
  • 1.4666
  • 1.6207
  • 1.3949
  • 1.5396
  • 1.3850
  • 1.4910
  • 1.4413
  • 2.2147 *
  • 1 4932..*.1 6734..*. 1. 4212...*.1 5831.*. 1. 4067
  • 1.5705..*. 1. 5001.*.2. 2278..*

10

  • 1.7205
  • 1.5130
  • 1.7606
  • 1.4939
  • 1.5477
  • 1.4339
  • 1.6070
  • 2.2862 *
  • 1.6496
  • 1.3980
  • 1.6054
  • 1.4005
  • 1.5201
  • 1.3967
  • 1.6096
  • 2.1960 *

..1 6802..*.1 4243..*.1. 6252.*.1 4379..*.1 5714..*.1. 4550..*. 1 6801.*.2. 1629.*

11

  • 1.5101'* 1.6724
  • 1.4992
  • 1.6619
  • 1.4326
  • 1.5609
  • 1.4498
  • 2.5412 *
  • 1.3850
  • 1.5411
  • 1.4037
  • 1.6065
  • 1.4208
  • 1.5901
  • 1.5486
  • 2.5690 *
  • 1 3994..*. 1. 5837..*. 1. 4392..**1 6396..*. 1 4582..*. 1 6653...*.1. 6080..*. 2. 52.*10.*

12

  • 1.6396
  • 1.d439
  • 1.5500
  • 1.4341
  • 1.5470
  • 1.4171
  • 1.8365 *
  • 1.5208
  • 1.3P56
  • 1.5216
  • 1.4222
  • 1.5540
  • 1.4338
  • 1.9384 *
  • 1. 5 7 4 5. +.1 4 0 6 6.. *. 1 5 7 2 8.. *
  • 1. 4 5 8 9...*
  • 1 619 9.. *.1 4 9 3 9. *..1 9 8 3 8.. *.

13

  • 1.4777
  • 1.5160
  • 1.4359
  • 1.5625
  • 1.4165
  • 1.8739
  • 2.6280 *
  • 1.4637
  • 1.4917
  • 1.3974
  • 1.5916
  • 1.4332
  • 1.9098
  • 2.5903 *
  • 1 5509..*.1 5705..+. 1 4550...*.1 6662..*. 1.,4937..*.1. 9134
  • 2. 4681.*

14

  • 1.7183
  • 1.4627
  • 1.6083
  • 1.4502
  • 1.8375
  • 2.6293 *
  • 1.6954
  • 1.4427
  • 1.6112
  • 1.5493
  • 1.9396
  • 2.5924 *
  • .1 7672.*.1 5008..*.1.6803..*. 1 6080..*.1 9838..*. 2. 4681.*.

15

  • 1.8267
  • 2.2765
  • 2.2895
  • 2.5454
  • 1. 7 6 5 5
  • 2. 217 9
  • 2.19 7 6
  • 2. 5 711
  • 2 0 0 EFPD 118 % POWER

. 1. 7916.... 2. 2306.*.2. 1632.*. 2 5210.* 405 EFPD 118 % POWER THIS IS LEVEL 15 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

....H.........C.........F.........E.........D.........C.........B........A 8

  • 1.9286
  • 1.5011
  • 1.7439
  • 1.4780
  • 1.6231
  • 1.4388
  • 1.6811
  • 1.7540 *
  • 1.8362
  • 1.4418
  • 1.6584
  • 1.3560
  • 1.5193 + 1.4534
  • 1.7019
  • 1.7477 *
  • 1. 8711..*.1 4859.*. 1 6965..*.1. 3861..*. 1. 5852..*. 1. 5568..*.1. 7889..*. 1 7899.*.

9

  • 1.5011
  • 1.6770
  • 1.4871
  • 1.6475
  • 1.3913
  • 1.4750
  • 1.3965
  • 2,2196 *
  • 1.4418
  • 1.6229
  • 1.3703
  • 1.5350
  • 1.3507
  • 1.4761
  • 1.4119
  • 2.2274 *
  • 1 4859.*. 1 6865..*.1..,4092..*.1 5894
  • 1 3917..*.1. 5737
  • 1.4891..*.2. 2576..a*
        • e 10
  • 1.7439
  • 1.492C
  • 1.7605
  • 1.4610
  • 1.5130
  • 1.3824
  • 1.5449
  • 2.2085
  • 1.6584
  • 1.3746 + 1.6071
  • 1.3721
  • 1.5025
  • 1.3643
  • 1.5915
  • 2.1868
  • 1 6965..*.1.4123..*.1 6340.*.1 4222.*. 1 5716.*.1 4455..*. 1. 6835..*. 2..'1793.*.

11

  • 1.4700
  • 1,6527
  • 1.4663
  • 1.6465
  • 1.3781
  • 1.5160
  • 1.3791
  • 2.4603 *
  • 1.3560
  • 1.5366
  • 1.3752
  • 1.5972
  • 1.3817
  • 1.5713
  • 1.5172 + 2.5626 *

. 1 3861.*.1. 5900..*.1. 4253..*.1. 6422..*. 1. 4542..*.1 6759..*..1 5993..*.2. 5492..*

)

12

  • 1.6231
  • 1.3920
  • 1.5151
  • 1.3775
  • 1.5012
  • 1.3573
  • 1.7713 *
  • 1.5193
  • 1.3507
  • 1.5032
  • 1.3830
  • 1.5352
  • 1.4024
  • 1.9235 *
  • 1. 5852...*.1 3921.*. 1 5724..*.1 4549.*.1. 6326.*.1 4946..*.2. 0037..*

13

  • 1.4388
  • 1.4763
  • 1.3843
  • 1.5174
  • 1.3567
  • 1.8145
  • 2.5610 *
  • 1.4534
  • 1,4768
  • 1.3649
  • 1.5720
  • 1.4024
  • 1.8976
  • 2.5891 *

. 1 5568

  • 1 5737..*.1. 4455
  • 1.6760.*.1 4940.*.1 9403..*. 2. 5135..*

+

14

  • 1.6811
  • 1.3983
  • 1.5472
  • 1.3803
  • 1.7723
  • 2.5631 *
  • 1.7019
  • 1.4132
  • 1.5931
  • 1.5180
  • 1.9247
  • 2.5893 *

. 1 7889.*. 1 4892..*.1 6844.*. 1 5993..*.2. 0037..*.2. 5155..*

15

  • 1.7540
  • 2.2243
  • 2.2115
  • 2.4642
  • 1.7477
  • 2.2306
  • 2.1883
  • 2.5647
  • 200 EFPD 118 % POWER

. 1 7 8 9 9. *. 2. 2 6 0 5..

  • 2. 18 05..*.2.

5 4 92.

  • 4 0 5 EFPD 118 % POWER

APPENDIX Page 121 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 3 (cont.)

M-sub-C Values (F-sub-Q RPS Margin) - Normal Operations THIS IS LEVEL 24 OF 10 (LEVEL 18. TOP OF CORE, LEVEL 1 = BOTTOM)

....H.........G.........F.........E.........D.........C.........B........A......

8

  • 2.0512
  • 1.5811
  • 1.8479
  • 1.5506
  • 1.7081
  • 1.5065
  • 1.7615
  • 1.8302 *
  • 1.9126
  • 1.5054
  • 1.7511
  • 1.4334
  • 1.6171
  • 1.5457
  • 1.8159
  • 1.8593 *

... 9637...... 5.10.. *.1. 8 019. *.1.4 6 3 2. *.1.6 8 3 4.. *.1 6 5 4 5. *.1 9101.. *.1.

9 0 4 6.. *

  • 1
  • 1.5 9
  • 1.5811
  • 1.7730
  • 1.5646
  • 1.7303
  • 1.4440
  • 1.5380
  • 1.4494
  • 2.3295 *
  • 1.5054
  • 1.6911
  • 1.4527
  • 1.6315
  • 1.4235
  • 1.5659
  • 1.4946
  • 2.3787 *

................ 1. 6849......1. 4694..*.1. 6707

  • 1 5748.*.2. 4126.*.

... 5510..*. 1 7676

  • 1.4897 *
  • 1 1.8479
  • 1.5709
  • 1.8688
  • 1.5164
  • 1.5685
  • 1.4255
  • 1.6028
  • 2.3071
  • 10 *
  • 1.7511
  • 1.4575
  • 1.7122
  • 1.4500
  • 1.5923
  • 1.4400
  • 1.6881
  • 2.3290 *

. 1 8.019 *.... 1 492.9 *.. 1 7367

  • 1 5020
  • 1 6663
  • 1 5295.*..1 7887...... 3279..*
  • 2 11
  • 1.5506
  • 1.7361
  • 1.5231
  • 1.7171
  • 1.4253
  • 1.5692
  • 1.4176
  • 2.5544 *
  • 1.4334
  • 1.6332
  • 1.4534
  • 1.6672
  • 1.4418
  • 1.6468
  • 1.5845
  • 2.7311 *

... 4632

  • 1 6865..*..1.5054... 1. 7171.*.1. 5238..*. 1. 7612..*.1. 6780
  • 2. 7237 1

12

  • 1.7081
  • 1.4447
  • 1.5709
  • 1.4259
  • 1.5627
  • 1.4052
  • 1.8382 *
  • 1.6171
  • 1.4242
  • 1.5931
  • 1.4438
  • 1.6168
  • 1.4749
  • 2.0320 *

. 1.6834..*. 1 4699 *...... 16674......1. 5247

  • 1 7249
  • 1. 5786
  • 2. 1220...*

1.5065

  • 1.5394
  • 1.4274
  • 1.5715
  • 1.4046
  • 1.8934
  • 2.6821
  • 13 *
  • 1.5457
  • 1.5667
  • 1.4413
  • 1.64'6
  • 1.4743
  • 2.0168
  • 2.7494 *

... 6545..*. 1 6707....... 1 5295

  • 1 7622..*. 1. 5786...*.2.0717. **2 6889.*
  • 1
  • e 14
  • 1.7615
  • 1.4515
  • 1.6045
  • 1.4182
  • 1.8393
  • 2.6844
  • 1.8159
  • 1.4953
  • 1.6890
  • 1.5853 + 2.0334
  • 2.7518 *
  • 1. 9101..*.1 5748.*. 1 7887
  • 1 6700
  • 2. 1220... 2. 6 8 9 3...*

15

  • 1.8302
  • 2.3347
  • 2.3105
  • 2.5605
  • 1.8593
  • 2.3842
  • 2.3307
  • 2.7335
  • 200 EFPD 118 4 POWER

. 1 9046..*.2 4159...... 2. 3279

  • 2.7237 *........... 405 EFFD 118 %

POWER THIS IS LEVEL 13 OF 18 (LEVEL 18 = TOP OF CORE. LEVEL 1 = BOTTOM)

......................F.........E.........D.........C.........B.......A......

H G

8

  • 2.1883
  • 1.6566
  • 1.9519
  • 1.6147
  • 1.7899
  • 1.5643
  • 1.8352
  • 1.8831 *
  • 2.0037
  • 1.5453
  • 1.8217
  • 1.5010
  • 1.7122
  • 1.6315
  • 1.9247
  • 1.9488 *

. 2. 0312... 1 5744............... 1. 5260.*.1. 7762..*. 1 7405..*. 2. 0152..*.1 9907 *

  • 1.8561 *
  • 1.6316
  • 1.8076
  • 1.4922
  • 1.5984
  • 1.4948
  • 2.4212
  • 1.6566
  • 1.8718 9
  • 1.5192
  • 1.7254 1.4881
  • 1.6531
  • 1.5659
  • 2.5171 *
  • 1.5453
  • 1.7178 *

. 1. 5744......1.8106

  • 1. 5524... 1 7752
  • 1.5319
  • 1.7621.*.1 6414.....2 5363..*

1.5714

  • 1.6282
  • 1.4689
  • 1.6582
  • 2.3970
  • 1.9668 10
  • 1.9519
  • 1.6384
  • 1.5243
  • 1.8016
  • 1.5106
  • 1.6578
  • 1.5009
  • 1.7776
  • 2.4537 *
  • 1.8217 *

. 1 8561.*. 1 5555.... 1. 8251.*. 1.5575.*.1.7450.*.1 5855

  • 1. 8820
  • 2.4413..*.

11

  • 1.6147
  • 1.8139
  • 1.5785
  • 1.7932
  • 1.4689
  • 1.6249
  • 1.4517
  • 2.6566 *
  • 1.5010
  • 1.7274
  • 1.5149
  • 1.7204
  • 1.4781
  • 1.6982
  • 1.6223
  • 2.0642
  • 4.............. 8151
  • 1. 7156..*.2. 8435 *
  • 1.5556
  • 1
  • 1 5260
  • 1.7772
  • 1.5621
  • 1.767 12
  • 1.7899
  • 1.4936
  • 1.6307
  • 1.4695
  • 1.6231
  • 1.4476
  • 1.9005
  • 1.6873 + 1.5271
  • 2.1084 *
  • 1.7122
  • 1.4888
  • 1.6601
  • 1.4807 2..*. 1 5319
  • 1. 7467......1. 5575.*.1 7988.............. 25
  • 2. 1937 *
  • 1.63
  • 1.776 1.6265
  • 1.4469
  • 1.9670
  • 2.7910
  • 13
  • 1.5643
  • 1.6001
  • 1.4710
  • 1.6315
  • 1.6540
  • 1.5023
  • 1.6991
  • 1.5267
  • 2.1042
  • 2.8583 *

... 7405..*.1.7621..*.1. 5855..*.1.8157

  • 1.6321.*.2 1673..*. 2. 8053 *
  • 1 14
  • 1.8352
  • 1.4970
  • 1.6600
  • 1.4524
  • 1.9016
  • 2.7933 *
  • 1.3247
  • 1.5667
  • 1.7786
  • 1.6229
  • 2.1098
  • 2.8609 *
  • 2.0152.*.1.6421.*.1 8820..... 1. 7156
  • 2. 1946.*.2 8062.*

15

  • 1.0831
  • 2.4288
  • 2.3989
  • 2.6612
  • 4 EFFD 118 4 POWER 1.9488
  • 2.5212
  • 2.4556
  • 2.8669
  • 200 EFPD 118 4 POWER
  • 2.8435
  • 405 EFPD 118 4 POWER

. 1. 9907

  • 2. 5384..*.2. 4432

APPENDIX Page 122 of 140 i

McGul x ' Cylce 10 Core Operating Lim 9s Report

{

1Dable 3 (cont.)

M-sub-C Values (F-sub-Q RPS Margin) - Normal Operations THIS IS LEVEL 12 CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTCM)

.............C.....,e..F.........E.........D.........C........B.........A.....

H 8

  • 2.4063
  • 1.8036
  • 2.1271
  • 1.7422
  • 1.9379
  • 1.6871
  • 1.9835
  • 2.0232 *
    • 14
  • 1.6781
  • 1.9747 + 1.6384
  • 1.8806
  • 1.7878
  • 2.1098
  • 2.1242 *

. 1 6904...*.1 9986......1. 6524..*.1. 9391.*.1 8956..*.2 1980.*. 2. 1570

  • 7
  • 1.6048
  • 2.6208
  • 9=
  • 2.0447
  • 1.7662
  • 1.9586
  • 1.6082
  • 1.7274 1.9094
  • 1.6430
  • 1.0750
  • 1.6190
  • 1.0046
  • 1.7075
  • 2.7552 *
  • 1.4 a 9557.... 1. 6568 *... 1. 9102..*. 1. 6508.....1 9 0 5 2...*.1 7 7 9 5.. *. 2. 7 5 61.. *.

1.6904

  • 1 10
  • 2.1271
  • 1.7744
  • 2.1402
  • 1.7045
  • 1.7665
  • 1.5891
  • 1.7878
  • 2.5860
  • 1.9245
  • 2.6887
  • 1.6481
  • 1.9569 + 1.6314
  • 1.7974
  • 1.6194 *
  • 1.9747
  • 1.9966
  • 1 6610 *..........C.7... 1. 6605..*.1 8678..*.1. 6912..*.2. 0194
  • 2. 6507..*.

1.96 1.7655

  • 1.5680
  • 2.8747
  • 11
  • 1.7422
  • 1.9650

.7121

  • 1.9525
  • 1.5899
  • 1.6384
  • 1.881' t63
  • 1.8704
  • 1.5946
  • 1.8413
  • 1.7538
  • 3.0957

.... 1. 9020 *.... 1 6683.*. 1. 9518..*.1. 8382..*. 3. 0360

  • i6 *
  • 1.6524
  • 1 914 12
  • 1.9379
  • 1.6090 -../695
  • 1.5924
  • 1.7766
  • 1.5758
  • 2.0705
  • 1.6198
  • 1.7984 + 1.5976
  • 1.8266
  • 1.6468
  • 2.2831
  • 1.8806 1 6510..*.1.0689..*.1 6701.*.1 9318.... 1. 7465..*.2. 3492..*
  • 1.9391
  • 1.7283
  • 1.5915
  • 1.7665
  • 1.5752
  • 2.1548
  • 3.0603 1.6871 13
  • a 1.8431
  • 1.6465
  • 2.2848
  • 3.1194 *
  • 1.7878
  • 1.8056
  • 1.6211
  • 1 8956
  • 1. 9052.*. 1. 6912

.*.1 9526..*.1 7459

  • 2. 3173.*.3 0009.*.

14

  • 1.9835
  • 1.6074
  • 1.7899
  • 1.5688
  • 2.0719
  • 3.0633
  • 1.7094
  • 1.9257
  • 1.7548
  • 2.2848
  • 3.1223 *
  • 2.1098 1.7805
  • 2. 0205
  • 1 8382..*.2.3498
  • 3.0019..*
  • 2.1980
  • 2.0232
  • 2.6 2.5882
  • 2.8800
  • 4 EFPD 118 % POWER 15
  • 2.1242
  • 2.7s 2.6910
  • 3.0988
  • 2 00 EFPD 118 % FCWER
  • 3
  • 405 EFPD 118 % POWER

....... 0360 2.1570

  • 2.758
  • 2 6507 THIS IS LEVEL 11 OF 18 (LEVEL 18. TCP CF CORE, LEVEL 1 : BOTTOM)

H G

F E

D C

D A

8

  • 2.6208
  • 1.9828
  • 2.3307
  • 1.9244
  • 2.1432
  • 1.8626
  • 2.1791
  • 2.2046
  • 2.4288
  • 1.8461
  • 2.1837
  • 1.0325
  • 2.1184
  • 2.0117
  • 2.3715
  • 2.3769
  • 2 4361.*. 1 8570
  • 2. 2104..*.1 8253.*. 2. 1544..*.2. 1109..*.2. 4475.*. 2.3911..*

1 9

  • 1.9828
  • 2.2402
  • 1.9538
  • 2.1761
  • 1.7785
  • 1.9141
  • 1.7603
  • 2.8641
  • 2.1112
  • 1.8277
  • 2.0928
  • 1.8066
  • 2.0200
  • 1.9078
  • 3.0914
  • 1.8461 *

...... 2 1577

  • 1 8286
  • 2.1146..*. 1. 8188
  • 2 1075.*.1 9557..*. 3. 0602..*

1 8570

  • 10
  • 2.3307
  • 1.9625
  • 2.3554
  • 1.8843
  • 1.9586
  • 1.7531
  • 1.9785
  • 2.8562 *
  • 2.1837
  • 1.8330
  • 2.1700
  • 1.0128
  • 2.0009
  • 1.7979
  • 2.1446
  • 3.0166
  • 2104..... 1 8328
  • 2. 1718..*.1 8252..*.2.0637
  • 1 8551.*. 2. 2215
  • 2. 9179
  • 2 j
  • .e...

2.1837

  • 1.8936
  • 2.1640
  • 1.7541
  • 1.9537
  • 1.7266
  • 3.1862
  • 11
  • 1.9244 2.0494
  • 1.9397
  • 3.4395
  • 1.8325
  • 2.0998
  • 1.8170
  • 2.0664
  • 1.7736
  • 1 8304
  • 2 0935
  • 1 8318.*.2 1496
  • 2.0091.*. 3. 3299
  • 1.0253
  • 2.1187
  • 12
  • 2.1432
  • 1.7795
  • 1.9623
  • 1.7572
  • 1.9635
  • 1.7363
  • 2.2913
  • 1.7765
  • 2.0340
  • 1.8330
  • 2.5376 *
  • 2.1184
  • 1.8077
  • 2.0046 *
  • 2.1544
  • 1.8197
  • 2.0651
  • 1.8338
  • 2.1423
  • 1.9263
  • 2.5882
  • 1.9164
  • 1.7562
  • 1.9549
  • 1.7363
  • 2.3860
  • 3.3908 13
  • 1.8626 2.0200
  • 1.7990
  • 2.0519
  • 1.8330
  • 2.5355
  • 3.4471
  • 2.0117
  • 1075..*.1. 8551.*. 2 1509.*.1 9251..*.2. 5606.... 3 3154
  • 2.1109
  • 2
  • 2.1791
  • 1.7703
  • 1.9810
  • 1.7285
  • 2.2930
  • 3.3945
  • 14
  • 2.3715
  • 1.9090
  • 2.1461
  • 1.9409
  • 2.5376 * ?.4471 9569
  • 2. 2229.............. 2.5882..*.3.3177 *
  • 2.0091
  • 2.4475
  • 1 2.8720
  • 2.8615
  • 3.1928
  • 4 EFPD 118 % POWER 15 + 2.2046
  • 3.0976
  • 3.0166
  • 3.4395
  • 200 EFFD 118 % POWER 2.3769
  • 405 EFPD 118 % POWER
  • 2.3911
  • 3.0632
  • 2.9179
  • 3 3299

APPENDIX Page 17.3 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1Dable 3 (cont.)

M-subC Values (F-subQ RPS Margin) - Normal Operations THIS IS LEVEL 10 0F 18 (LEVEL 18. TOP OF CORE, LEVEL 1 = DOTTOM)

.............G.........F.........E....*....D.........C........B.........A.....

H 8

  • 2.7922
  • 2.0921
  • 2.4731
  • 2.0380
  • 2.2947
  • 2.0052
  • 2.3536
  • 2.3604 *

.* 2.6702

  • 2.0091
  • 2.3934
  • 1.991)
  • 2.3186
  • 2.2195
  • 2.6363
  • 2.6230 *

.......... 0202... 2. 4029

  • 2 3452.*.2. 7141.*.2. 6282..*

. 2. 7144.*.2. 0559.*.2.4674 *2 9

  • 2.0921
  • 2.3769
  • 2.0571
  • 2.3031
  • 1.9077
  • 2.0664
  • 1.9112
  • 3.0884 *
  • 2.0091
  • 2.3151
  • 1.9861
  • 2.2846
  • 1.9722
  • 2.2132
  • 2.0830
  • 3.4168 *
  • 2. 0559....... 4046..... 2. 0262
  • 2. 3560.*.2.0103..*.2.3404.... 2. 1485......3. 3734..*.
  • 2 2.0654
  • 2.4989
  • 2.0139
  • 2.1155
  • 1.8971
  • 2.1446
  • 3.0701
  • 10
  • 2.4731 *
  • 2.3934
  • 1.9911
  • 2.3769
  • 1.9735
  • 2.1898
  • 1.9635
  • 2.3483
  • 3.2836 *

.......... 2. 0312..*.2. 4207... 2. 0154..*. 2. 2957.... 2. 0424.*. 2. 4497

  • 3. 2074..*.
  • 2.4674
  • 11
  • 2.0380
  • 2.3117
  • 2.0232
  • 2.3186
  • 1.8982
  • 2.1256
  • 1.8705
  • 3.4395
  • 1.9911
  • 2.2930
  • 1.9798
  • 2.2630
  • 1.9343
  • 2.2434
  • 2.1155
  • 3.7319 *

.... 202

  • 2.3595
  • 2. 02.19... 2. 3263..*. 2. 0147.*.2. 3735..*.2. 2010..*.3 6587 *
  • 2.0 1.9100
  • 2.1190
  • 1.9018
  • 2.1446
  • 1.8912
  • 2.5009
  • 12
  • 2.2947
  • 2.3186
  • 1.9735
  • 2.1929
  • 1.9379
  • 2.2306
  • 1.9988
  • 2.7699 *

. 2. 4029.*.2. 0114..*. 2 2974.*. 2. 0171.*.2. 3591.*.2. 1014..*. 2. 8329..*

13

  • 2.0052
  • 2.0678
  • 1.8994
  • 2.1271
  • 1.8901
  • 2.6077
  • 3.6747 *
  • 2.2195
  • 2.2132
  • 1.9648
  • 2.2451
  • 1.9975
  • 2.7798
  • 3.7726 *

. 2 3 4 5 2.. *. 2. 3 3 8 8..*.2.

0 4 2 4.. *. 2. 3 7 3 5

  • 2. 10 0 2.. *. 2 8 0 7 4.. *. 3. 6 2 8 9. +.
  • 1.8717
  • 2.5029
  • 3.6790
  • 14
  • 2.3536
  • 1.9136
  • 2.1476
  • 2.6363
  • 2.0844
  • 2.3500
  • 2.1169
  • 2.7724
  • 3.7726 *
  • 2.7141..*. 2. 1485..*.2 4510.*.2.2010.*. 2. 8329..*.3 6209.*.

15

  • 2.3604
  • 3.0976
  • 3.0731
  • 3.4471 4 EFPD 118 4 POWER
  • 2.6230
  • 3.4243
  • 3.2871
  • 3.7319
  • 200 EFPD.18 % POWER

. 2. 6282..*.3 3771.*.3 2074.... 3. 6581.* 405 ETPD 118 4 POWER THIS IS LEVEL 9 CF 18 j

BOTTOM) 1 (LEVEL 18 e TOP OF CCRE, LEVEL 1 a

......................F.........E.........D.........C.........B.........A......

H G

8

  • 2.8023
  • 2.1166
  • 2.4869
  • 2.0598
  • 2.3134
  • 2.0143
  • 2.3824
  • 2.4352 *
  • 2.7625
  • 2.0844
  • 2.4751
  • 2.0719
  • 2.4119
  • 2.3307
  • 2.8073
  • 2.8641 *
  • 2.9706
  • 2. 2762.*.2. 7097
  • 2. 2451..*. 2.6566..*. 2 5946
  • 3.0108.*.2. 9342..*

j 1.9244

  • 3.1668
  • 9
  • 2.1166
  • 2.3934
  • 2.0822
  • 2.3220
  • 1.9172
  • 2.0774
  • 2.0844
  • 2.3934
  • 2.0623
  • 2.3697
  • 2.0569
  • 2.3220
  • 2.2038
  • 3.7141
  • i

. 2. 2762..*.2.6386........2. 248.3

  • 2 601.1.... 2354
  • 2.5925
  • 2. 3952
  • 3.7589.*

l

  • 2 10
  • 2.4869
  • 2.0907
  • 2.5151
  • 2.0353
  • 2.1271
  • 1.9006
  • 2.1565
  • 3.1540
  • 2.0678
  • 2.4614
  • 2.0569
  • 2.2812
  • 2.0569
  • 2.4869
  • 3.5411 *
  • 2.4751 *

.......... 2.2532.................. 2402

  • 2 5376......2. 2746
  • 2.7215
  • 3. 5654
  • 2.6702
  • 2
  • 2.7097
  • 11
  • 2.0598
  • 2.3307
  • 2.0461
  • 2.3394
  • 1.9018
  • 2.1300
  • 1.8947
  • 3.5290 *
  • 2.0719
  • 2.3787
  • 2.0623
  • 2.3500
  • 2.0248
  • 2.3518
  • 2.2402
  • 4.0260 *
  • 2. 245.1..*.2. 6055..*.2 2467....... 5690
  • 2. 2386
  • 2. 6274
  • 2. 4479.*.4. 0628 *
  • 2 j

1.9053

  • 2.1520
  • 1.8982
  • 2.5293
  • 12
  • 2.3134
  • 1.9184
  • 2.1314 *
  • 2.4119
  • 2.0609
  • 2.2879
  • 2.0274
  • 2.3324 998
  • 2.9481 *

. 2 6566..*. 2.2354........2.5396.*. 2 2418..*.2. 6077

  • b
  • 3. 1476..*

'77 13

  • 2.0143 + 2.0802
  • 1.9041
  • 2.1329
  • 1.8971
  • 2.0.08
  • 3.8048
  • 2.3307
  • 2.3220
  • 2.0596
  • 2.3536
  • 2.0998
  • 2.9621
  • 4.0734 *

. 2. 5946

  • 2 5903.+. 2. 2746
  • 2. 6274...... 3359
  • 3. 1130
  • 4. 0260 *
  • 2 14
  • 2.3824
  • 1.9268
  • 2.1610
  • 1.8971
  • 2.5314
  • 3.8048 *
  • 2.8073
  • 2.2038
  • 6.4889
  • 2.2418
  • 2.9509
  • 4.0734
  • 0108........ 3952....... 15
  • 2. 4479.....3. 1476
  • 4 0260 *
  • 2.
  • 2.72
  • 3 15
  • 2.4352
  • 3.1733
  • 3.1572
  • 3.5330
  • 2.8641
  • 3.7186
  • 3.5451 4.0260
  • 200 EFPD 118 % PCWER

...................... 654... 4.0628

2.9342

  • 3.7589
  • 3.5 POWER

~ L1 APPENDIX -

Page 124 of 140

' McGuire 2 Cylce 10 Core Operating Limits Report Table 3 (cont.)

M-sub-C Values (F-sub-Q RPS Margin) - Normal Operations THIS IS LEVEL 8 0F 18 i

(LEVEL 18 = TOP OF CORE. LEVEL 1 = BOTTOM)

....H.........G........F.........E.........D.........C.........B.........A..**..

e 8 + 2.6634

  • 1.9866
  • 2.3483
  • 1.9292
  • 2.1685
  • 1.8920
  • 2.2418
  • 2.2799'*
  • 2.5860
  • 1.9574
  • 2.3237
  • 1,9464
  • 2.2729
  • 2.1922
  • 2.6186
  • 2.6363 *
  • 2. 7848..*.2. 1198..*.2.5396.*.2. 0970..*. 2. 4889.*.2 4269.*. 2. 8303.*.2. 7552..*.

9* 1.9866

  • 3.2597
  • 1.9513 + 2.1837 + 1.8110
  • 1.9698
  • 1.8153
  • 2.9649 *
  • 1.9574
  • 2.2467
  • 1,9391
  • 2.2386
  • 1.9331
  • 2.1945
  • 2.0692
  • 3.4357 *
  • 2. 1198..*.2 4712..*.2. 0970.*. 2. 4383..*.2. 0914..*. 2. 43.64..*.2. 2499.*. 3. 5411
  • 10
  • 2.3483
  • 1.9600
  • 2.3733
  • 1.9136
  • 2.0169
  • 1.8057
  • 2.0555
  • 2.9593 *
  • 2.3237
  • 1.9452
  • 2.3168
  • 1.9367
  • 2.1595
  • 1.9367
  • 2.3465 *-3.3045 *

. 2. 5 3 9 6.. *.2.1012.. *. 2. 5 0 0 9. *. 2. 0 9 4 2.. *. 2,18 0 6.. *. 2. 13 2 9. *. 2. 5 6 0 5...*. 3. 3 615.. *.

11

  • 1.9292
  • 2.1929
  • 1.9208
  • 2.2069
  • 1 6078
  • 2.0340
  • 1.8078
  • 3.3471 *
  • 1.9464
  • 2.2451
  • 1.9415
  • 2.2226
  • 1.9071
  • 2.2274
  • 2.1084
  • 3.7771 *
  • 2. 0970..*.2. 442.1.**2 0998..*.2. 4082..*.2. 0998.*.2. 4731.*. 2. 2964...*.3. 8424..*.

12

  • 2.1685
  • 1.8131
  • 2.0182
  • 1.8110
  • 2.0514
  • 1.8110
  • 2.4175 *
  • 2.3729
  • 1.9355
  • 2.1655
  • 1.9106
  • 2.2116
  • 1.9810
  • 2.7897 *
  • 2. 4 8 8. 9
  • 2. 0 9 2 8...*. 2. 3 8 2 4.. *. 2. 1012.. *. 2. 4 5 3 7...*. 2. 19 6 0.. *
  • 2. 9 67 8..
  • 13
  • 1.8920
  • 1.9722
  • 1.8089
  • 2.0354 + 1.8099 + 2.5212
  • 3.6067 *
  • 2.1822
  • 2.1945
  • 1.9391
  • 2.2290
  • 1.9810
  • 2.8023
  • 3.8282 *

. 2. 4269.*.2. 4345..*. 2. 1329..*.2. 4731..*.2. 1945..*.2. 9398..*.3. 8141

  • a 14
  • 2.2418
  • 1.6185
  • 2.0502
  • 1.8099
  • 2.4194
  • 3.6108 *
  • 2.6186
  • 2.0705
  • 2.3483
  • 2.1084
  • 2.7897
  • 3.8282 *
  • 2. 8303.*.2. 2499..*.2.5605..*.2. 2964..*.2. 9678
  • 3 8141.*

15

  • 2.2799
  • 2.9706
  • 2.9621
  • 3.3507
  • 2.6363
  • 3.4395
  • 3.3080
  • 3.7771
  • 200 EFPD 118 % POWER

. 2. 7552..*. 3. 5451.*. 3. 3579..+. 3. 8424.*. 405 EFPD 118 4 POWER i

THIS IS LEVEL 7 OF 18 (LEVEL 18. TCP OF CORE, LEVEL 1 = BOTTOM)

  • ...H.......C.........F.........E.........D..**.....C.........B.**......A.**..

8

  • 2.4989
  • 1.8447
  • 2.1791
  • 1.7833 2.0122
  • 1.7526 2.0768
  • 2.1032 *
  • 2.4231
  • 1.8202
  • 2.1655
  • 1.7940
  • 2.0914
  • 2.0043
  • 2.3945
  • 2.3933 *

. 2. 5431.*.1 9318

  • 2. 3159..*. 1. 9096
  • 2. 2703..*.2. 2103..*. 2. 5778..*.2.5023..*

.9

  • 1.0447
  • 2.1027
  • 1.8082
  • 2.0314
  • 1.6818
  • 1.8302
  • 1.6693
  • 2.7390 *
  • 1.8202
  • 2.0956
  • 1.7929
  • 2.0678
  • 1.7834
  • 2.0176
  • 1.8899
  • 3.1338 *
  • 1 9318
  • 2.*.2539
  • 1 9108..***2 2221
  • 1.9035..*.2 2170..**2. 0423..**3 2206.*

10

  • 2.1791
  • 1.8163
  • 2.2038
  • 1.7775
  • 1.8817
  • 1.6811
  • 1.8989
  • 2.7242 *
  • 2.1655
  • 1.7981
  • 2.1476 + 1.7886
  • 1.9983
  • 1.7886
  • 2.1467
  • 3.0057 *

. 2. 3.159..*. 1. 9143

  • 2. 2786..*.1 9061
  • 2. 1692..*. 1. 9387
  • 2. 3258
  • 3. 0504..*

11

  • 1.7833
  • 2.0394
  • 1.7837
  • 2.0664
  • 1.6914
  • 1.9059
  • 1.6951
  • 3.0967 *
  • 1.7940
  • 2.0747
  • 1.7927
  • 2.0672
  • 1.7756
  • 2.0664
  • 1.9350
  • 3.4620 *
  • 1. 9096
  • 2. 2253..*.1 9105..*.2. 1940.*.1 9105..*.2. 2506..*. 2. 0825.*.3 4844.*.

12

  • 2.0122
  • 1.6829
  • 1.8829
  • 1.6942
  • 1.9561
  • 1.7140
  • 2.2679 *

[

  • 2.0914
  • 1.7844
  • 2.0022
  • 1.7786
  • 2.0623
  • 1.8482
  • 2.5775 *
  • 2. 2703.*.1. 9038.*. 2. 1707..*.1. 9128..*. 2. 2345.*.1. 9.949..*. 2. 6.937..*

i 7

13

  • 1.7526
  • 1.8310
  • 1.6829
  • 1.9082
  • 1.7131
  • 2.3934
  • 3 3798 *
  • 2.0043
  • 2.0176
  • 1.7896
  • 2.0678
  • 1.8482
  • 2.6164
  • 3.5492 *

. 2. 2103..*.2 2166 + 1. 9378

  • 2. 2506...*.1 9.949..*.2. 6706
  • 3. 4573.*

14

  • 2.0768
  • 1.6721
  • 1.9012
  • 1.6961
  • 2.2696
  • 3.3834 *
  • 2.3945
  • 1.8910
  • 2.1482
  • 1.9362
  • 2.5796
  • 3.5492
  • 1

. 2.5778

  • 2. 0433.*. 2. 3258..*. 2. 0815
  • 2.6943..*.3. 4573..*.

15

  • 2.1032
  • 2.7438
  • 2.7270
  • 3.1004
  • 2.3933
  • 3.1389
  • 3.0068
  • 3.4622
  • 200 EFPD 118 % POWER
  • 2. 5 0 2 3.. *. 3 2 2 3 9.*. 3 0 5 0 4. *. 3 4 815..
  • 4 0 5 EFPD 110 t POWER h

.--n.--

APPENDIX Page 125 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 3 (cont.)

M-sub-C Values (F-sub-Q RPS Margin) - Normal Operations THIS IS LEVEL 6 OF 1R (LEVEL 18 = TCP CF CORE, LEVEL 1 = BOTTCM)

.............G.........F.........E.........D.........C........B.........A......

H 1.9382

  • 1.9759
  • 1.6535
  • 1.8690
  • 1.6267
  • 8
  • 2.3057
  • 1.7060
  • 2.0203
  • 2.2278
  • 1.6684
  • 1.9789
  • 1.6499
  • 1.9220
  • 1,8418
  • 2.2096
  • 2.2174 *

..... 07

  • 1. 7700
  • 2. 1216.*. 1. 7472..*.2. 0816
  • 2. 0281.*.2 3657..*. 2. 3006
  • 2.33 9
  • 1.7060
  • 1.9437
  • 1.6751
  • 1.8851
  • 1.5568
  • 1.6975
  • 1.5643
  • 2.5732 *
  • 1.6684
  • 1.9184
  • 1.6454
  • 1.8949
  • 1.6368
  • 1.8506
  • 1.7329
  • 2.9033 *

. 1. 7700......2. 0641..*.1 7482..*. 2. 0327..... 7394..*.2. 0321.... 1. 8713..*.2. 9644..*

  • 1 10
  • 2.0203
  • 1.6826
  • 2.0455
  • 1.6461
  • 1.7424
  • 1.5560
  • 1.7702
  • 2.5517
  • 1.9789
  • 1.6501
  • 1.9684
  • 1.6403
  • 1.8320
  • 1.6379
  • 1.9671
  • 2.7744 *

... 12.16

  • 1 7521.*.2. 0862..*.1 7411.*.1 9845..*. 1 7710
  • 2. 1315..*.2. 8056 *
  • 2

..e**..

11

  • 1.6535
  • 1.8930
  • 1.6526
  • 1.9094
  • 1.5602
  • 1.7609
  • 1.5672
  • 2.8913 *
  • 1.6499
  • 1.9007
  • 1.6438
  • 1.8896
  • 1.6192
  • 1.8874
  • 1.7729
  • 3.1811 *

. 1 7472..*. 2. 0367..*.1 7460.*.2. 0062..*.1 7423..*.2. 0565..*.1 9056..*.3 2013..*

12

  • 1.8690
  • 1.5584
  • 1.7434
  • 1.5632
  • 1.7929
  • 1.5751
  • 2.1025
  • 1.8353
  • 1.6217
  • 1.8863
  • 1.6820
  • 2.3579
  • 1.9220
  • 1.6377 *

... 08162.....*.1.7401.*.1.9867.... 1. 7440

  • 2 0404.*. 1. 8215..*. 2. 4664.*

13

  • 1.6267
  • 1.6986
  • 1.5576
  • 1.7619
  • 1.5743
  • 2.2108
  • 3.1502
  • 1.8517
  • 1.6396
  • 1.8886
  • 1.6820
  • 2.3648
  • 3.2647 *
  • 1.8418 *
  • 2.0

..... 3. 1711..*

.... 281.*.2.0311..*. 1. 7708

  • 2. 0565..*.1 8204.*.2.4427 14
  • 1.9382
  • 1.5665
  • 1.7723
  • 1.5686
  • 2.1054
  • 3.1528
  • 3.2647
  • 2.2096
  • 1.7339
  • 1.9694
  • 1.7735
  • 2.3596 *

. 2. 3657.......18713......2. 1315.*.1 9044..*.2. 4664

  • 3. 1711..*

1.9759

  • 2.5796
  • 2.5542
  • 2.8949
  • 4 EFPD 118 % POWER 15 *
  • 2.2174
  • 2.9087
  • 2.7769
  • 3.1815
  • 200 EFPD 118 4 POWER
  • 2
  • 405 EFFD 118 % POWER

. 2. 3006....... 9673.*.2. 8056

  • 3. 2004 THIS IS LEVEL 5 0F 18 (LEVEL 18 = TOP OF COPE, LEVEL 1 = BOTTOM)

....H.........G.........F.........E.........D.........C.......B.........A.....

1.8439

  • 1.5092
  • 1.7143
  • 1.4852
  • 1.7878
  • 1.8191
  • 8
  • 2.1057
  • 1.5471
  • 2.0091
  • 2.0043
  • 1.7414
  • 1.6644 2.0073
  • 1.4893
  • 1.7880
  • 1.4809 *

. 2. 0958......1 5775

  • 1.9031.*. 1.5578
  • 1.8667....................137
  • 2. 1257
  • 2. 0584..*.
  • 1.8 9
  • 1.5471
  • 1.7702
  • 1.5210
  • 1.7219
  • 1.4172
  • 1.5536
  • 1.4288
  • 2.3855
  • 1.7112
  • 1.4692
  • 1.6698
  • 1.5551
  • 2.6420
  • 1.4735
  • 1.4893 1.7266

........ 8514

  • 1 5586
  • 1. 8221..*.1 5515
  • 1 8221.*.1. 6700..*. 2 6611..*.

. 1 5775

  • 1 10
  • 1.8439
  • 1.5286
  • 1.8707
  • 1.4985
  • 1.5919
  • 1.4153
  • 1.6197
  • 2.3545
  • 1.4716
  • 1.6512
  • 1.4644
  • 1.7712
  • 2.5132 *
  • 1.7880
  • 1.4777
  • 1.7804 *

. 1 9031.*.1. 5617......1 8690

  • 1. 5515..*.1 7796
  • 1 5778..*e**.9092..*.2. 5176
  • 1 11
  • 1.5082
  • 1.7287
  • 1.5051
  • 1.7442
  • 1.4166
  • 1.6060
  • 1.4227
  • 2.6640 *
  • 1.4809
  • 1.7175
  • 1.4755
  • 1.7000
  • 1.4450
  • 1.6944
  • 1.5837
  • 2.8?73 *

. 1. 5578

  • 1. 8253..*. 1. 5555..*.1 7980..*. 1. 5523..*.1 8429
  • 1. 6994.*. 2. 8767 12
  • 1.7143
  • 1.4185
  • 1.5929
  • 1.4192
  • 1.6258
  • 1.4252
  • 1.9221 *
  • 1.7414
  • 1.4700
  • 1.6537
  • 1.4474
  • 1.6875
  • 1.4989
  • 2.1177 *

..1 8667.... 1. 5523

  • 1. 7806 *... 1. 5538 *.... 1 8275
  • 1. 6232..*.2. 2.095...*

13

  • 1.4852
  • 1.5552
  • 1.4172
  • 1.6076
  • 1.4245
  • 2.0167
  • 2.8957 *
  • 1.6644
  • 1.6707
  • 1.4658
  • 1.6954 1.4982
  • 2.1420
  • 2.9456
  • 37....1 8221..*.1. 5776..... 1 8429... 1. 6226.....2 1916. **.... 2. 8504
  • 1.81 i

14

  • 1.7878
  • 1.4308
  • 1.6222
  • 1.4241
  • 1.9242
  • 2.8983
  • 1.5567 1.7724 1.5838
  • 2.1192
  • 2.9479 *
  • 2.0091

. 2. 1257... 1 6700......1 9092..*.1. 6994..*.2. 2095

  • 2. 8505
  • 2.J910
  • 2.3581
  • 2.6686
  • 4 EFPD 118 % POWER 15
  • 1.8191 *
  • 2.0043
  • 2.6465
  • 2.5153
  • 2.8776
  • 200 EFFD 118 % POWER 584.....2.6634................... 8767
  • 405 EFPD 118 % POWER
  • 2.0
  • 2.5176 *2

APPENDIX Page 126 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 3 (cont.)

M-sub-C Values (F-sub-Q RPS Margin) - Normal Operations THIS IS LEVEL 4 OF 18 (LEVEL 18 = TOP OF CORE. LEVEL 1 = DOTTOM)

....H.**...0.........F.........E.........D.........C.........D.....*e..A....

1.4319

  • 1.7338
  • 1.7823
  • 8
  • 2.0131
  • 1.4808
  • 1.7630
  • 1.4505
  • 1.6468 *
  • 1.9034
  • 1.4138
  • 1.6938
  • 1.4076
  • 1.6516
  • 1.5795
  • 1.9060
  • 1.9125 *

. 1 9201.*. 1.4431.*. 1 7387..*. 1 4230 *... 1 7031.*.1. 6557

  • 1 9412.*.1.8924 1.6909
  • 1.4582
  • 1.6547
  • 1.3681
  • 1.5015
  • 1.3875
  • 2.3324
  • 9
  • 1.4808
  • 1.3942
  • 1.5828
  • 1.4765
  • 2.5158 *
  • 1.4138
  • 1.6355
  • 1.3993
  • 1.6204 4.31..*.1 6929.*.1 4237...*.1. 6605..*. 1. 4166.*.1 6632
  • 1. 5287..*.2. 4429..*
  • 1.4 1.7916
  • 1.4410
  • 1.5349
  • 1.3649
  • 1.5709
  • 2.3045
  • 1.7630
  • 1.4658
  • 10
  • 1.6938
  • 1.4040
  • 1.6867
  • 1.3941
  • 1.5610
  • 1.3838
  • 1.6776
  • 2.3970 *

..... 4269.... 1 7059....1 4162..*.1 6229.*.1 4418......1. 7460

  • 2. 3.134..*
  • 1.

. 1.7387 11

  • 1.4505
  • 1.6619
  • 1.4472
  • 1.6724
  • 1.3662
  • 1.5495
  • 1.3788
  • 2.6032 *
  • 1.6250
  • 1.3986
  • 1.6098
  • 1.3636
  • 1.5983
  • 1.4993
  • 2.7341
  • 1.4076 632..*.1. 4204
  • 1.6400.*.1. 4172..*.1 6820......1 5562..*.2. 6460 a.4230
  • 1.6 1.3686
  • 1.5629
  • 1.3741
  • 1.8654
  • 12
  • 1.6468
  • 1.3698
  • 1.5356
  • 1.3955
  • 1.5634
  • 1.3660
  • 1.5891
  • 1.4129
  • 1.9998
  • 1.6516 *

. 1 7031..*.1. 4166.*.1 6242..*. 1. 4185..*. 1 6672..*.1. 4847.........

256 *

  • 2.0 13
  • 1.4319
  • 1.5029
  • 1.3674
  • 1.5505
  • 1.3730
  • 1.9501
  • 2.8188 *
  • 1.5795
  • 1,5836
  • 1.3853
  • 1.6000
  • 1.4123
  • 2.0195
  • 2.7904

.......... 37 *

. 1. 6557........ 6623..+.1. 4418.... 1 6820..*.1.4840.*.2. 0098

  • 2.62...
  • 1 1.3800
  • 1.8667
  • 2.8213
  • 1.7338
  • 1.3894
  • 1.5733 14
  • 2.0011
  • 2.7907 1.5001 *
  • 1.9060
  • 1.4772
  • 1.6194 *

. 1. 9412...... 5288.....1.7461...*.1 5558.... 2.0256.... 2. 6237

  • 1.

15

  • 1.7823
  • 2.3380
  • 2.3079
  • 2.6075
  • . 9125
  • 2.5199
  • 2.3988
  • 2.7341
  • 200 EFPD 118 % POWER
  • 405 EFPD 118 4 POWER e.1 8924.*.2 4458
  • 2. 3134.*.2. 6449 THIS IS LEVEL 3'OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1. BOTTOM)

....H.........G.........F.........E.........D.........C.........B.....e...A.....

1.7684

  • 8
  • 1.9287
  • 1.4164
  • 1.6829
  • 1.3918
  • 1.5791
  • 1.3853
  • 1.6991 *
  • 1.5018
  • 1.0200
  • 1.8357
  • 1.6152
  • 1.3395
  • 1.5736
  • 1.8212
  • 1.3489 *
  • 1. 7711..*. 1 3253..*. 1 5999.*.1.3034.*. 1. 5615..*. 1 5145..*. 1 7788... 1 7387 1.6171
  • 1.3918
  • 1.5831
  • 1.3270
  • 1.4591
  • 1.3592
  • 2.3066
  • 9
  • 1.4164 *
  • 1.3489
  • 1.5613
  • 1.3332
  • 1.5411
  • 1.3280
  • 1.5114
  • 1.4116
  • 2.4094 *

..... 1 5249

  • 1.3994...............

2 2430

... 3253........ 55871......*.1.

3059.*.1 5211..*.1 2969

  • 1.

1.3988

  • 1.7080
  • 1.3842
  • 1.4858
  • 1.3259
  • 1.5386
  • 2.2809
  • 10
  • 1.6829 *
  • 1.6152
  • 1.3374
  • 1.6074
  • 1.3297
  • 1.4894
  • 1.3208
  • 1.6028
  • 2.3018 *

... 5999 *..... 1 3089 *..... 1 5673.*. 1 2977....... 1 4906.....1.3195..*.1 5991.*.2. 1290

  • 1.

11

  • 1.3918
  • 1.5904
  • 1.3899
  • 1.6069
  • 1.3276
  • 1.5091
  • 1.3580
  • 2.5903
  • 1.5264
  • 1.4339
  • 2.6315 *
  • 1.3395
  • 1.5467
  • 1.3338
  • 1.5359 1.2997 *

. 1 3034..*.1 5241.*.1 3015 *...... 1 5061..*.1. 2975..*. 1. 5430

  • 1. 4269.*. 2. 4423..*.

12

  • 1.5791
  • 1.3282
  • 1.4865
  • 1.3300
  • 1.5188
  • 1.3422
  • 1.8399 *
  • 1.5736
  • 1.3293
  • 1.4924
  • 1.3023
  • 1.5152
  • 1.3400
  • 1.9137 *

... 5615.*.1 2972..*..1 4917

  • 1 2988..*.1 5297.....1. 3606.....1.8621..*
  • 1 1.3853
  • 1.4606
  • 1.3276
  • 1.5113
  • 1.3416
  • 1.9185
  • 2.7966
  • j 13
  • 1.5273
  • 1.3474
  • 1.9354
  • 2.6839
  • i
  • 1.5010
  • 1.5115
  • 1.3220

.....145 *.....1.5241.... 1. 3192

  • 1. 5430 *.................. 529
  • 2.4262 1.3600 1.8 1.5 1.3592
  • 1.8418
  • 2.7991
  • 14
  • 1.6991
  • 1.3610
  • 1.5408 *
  • 1.8200
  • 1.4123
  • 1.6037
  • 1.4340
  • 1.9149
  • 2.6859 *

)

. 1 7788 *...... 1 3997.*. 1.5991..*.1.4269..*.1.8627

  • 2. 4262..*.

2.3117

  • 2.2843
  • 2.5946
  • 4 EFPD 118 4 POWER 15
  • 1.7684
  • 1.8357
  • 2.4134
  • 2.3035
  • 2.6315
  • 200 EFFC 118 % POWER

. 1. 7387..... 2447 *....... 1290.... 2. 4404.....405 EFPD 118 %

  • 2.

2 FOWER

APPENDIX Page 127 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 3 (cont.)

M-sub-C Values (F-sub-Q RPS Margin) - Normal Operations THIS IS LEVEL 2 OF 18 (LEVEL 18 = TOP OF CORE. LEVEL 1 = BOTTOM)

....H.........C........F........E........D........C.........B.........A 8

  • 1.9809
  • 1.4710
  • 1.7314
  • 1.4432
  • 1.6257
  • 1.4823
  • 1.8356
  • 1.9903
  • 1.3824
  • 1.6180
  • 1.5649
  • 1.8984
  • 1.9731 *
  • 1.8767
  • 1.4014
  • 1.6678 *

..1 760.3.*.1 3543..*.1 5968..*. 1 3074..*. 1 54.93..*.1 5096.*.1 7664..*. 1 7700.*

1.6153

  • 1.4111
  • 1.5515
  • 1.4777
  • 2.5118
  • 9
  • 1.4710
  • 1.6768
  • 1,4330 *
  • 1.4014
  • 1.6200
  • 1.3808
  • 1.5774
  • 1.3745
  • 1.5794
  • 1.5028
  • 2.5164 *

. 1 3343..*.1 5601.*. 1. 3124.*. 1 5084..*.1. 3003..*. 1. 5258..*.1.4090..*. 2. 2393.*.

1.5631

  • 1.4139
  • 1.6673
  • 2.5199
  • 10
  • 1.7314
  • 1.4404
  • 1.7420
  • 1.4417 *
  • 1.6678
  • 1.3854
  • 1.6556
  • 1.3930
  • 1.5482
  • 1.3890
  • 1.6877
  • 2.4483
  • 5968..... 1. 3154.*.1 5660...... 1 3 014.. *.1 4 915.. *.1.

3 2 4 9...*.1 6 0 2 2...*. 2. 15 4 2.. *

  • 1.

1.(222

  • 1.4480
  • 1.6616
  • 1.4145
  • 1.6090
  • 1.5116
  • 2.8814
  • 11
  • 1.4432 1.3588
  • 1.6007
  • 1.5343
  • 2.8044
  • 1.3824
  • 1.5831
  • 1.3969
  • 1.5880 *

..1 3074.......1 5114.. *.1 3 0 5 0..*.1.

5 0 7 3.

  • 1. 3 0 3 3. *.1.

5 4 7 0.. *.1 4 5 0 0...*. 2. 4 716. * **

  • 1.5641
  • 1.4184
  • 1.6140
  • 1.4601
  • 2.0257 1.4131 1.6257 12 *
  • 1.5867
  • 1.4362
  • 2.0270
  • 1.6180
  • 1.3763 + 1.5520
  • 1.3618

. 1. 5493.*.1 3009......1. 4926..*.1. 3047.... 1 5340.*.1.3742..*.1 8803 13

  • 1.4823
  • 1.5530
  • 1.4158
  • 1.6115
  • 1.4594
  • 2.0803
  • 3.0857
  • 1.4356
  • 2.0376
  • 2.8617 *
  • 1.5649
  • 1.5803
  • 1.3902
  • 1.6016

..1 5096..*.1 5254.*.1.3244.*..1 5470.*.1 3734...*.1 8711.*.2. 4638..*

1.6700

  • 1.5131
  • 2.0270
  • 3.0857
  • 14
  • 1.8356
  • 1.4799 *
  • 1.8984
  • 1.5036
  • 1.6886
  • 1.5350
  • 2.0283
  • 2.8617 *

..1 7664.*. 1.40.94...*.1 6022...*.1.4.496.*.1 0809.....2. 4638.*

15

  • 1.9903
  • 2.5175
  • 2.5240
  • 2.8841
  • 1.9731
  • 2.5205
  • 2.4486
  • 2.8044
  • 200 EFPD 118 % POWER

... 7700.*.2 2409

  • 2. 1542..*. 2 4697
  • 1 POWER THIS IS LEVEL 1 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

......................F.........E.........D.........C.........D.........A H

G 1.8870

  • 2.2556
  • 2.2042
  • 2.6734
  • 3.1997
  • 8
  • 2.6431
  • 1.9829
  • 2.4430
  • 1.8387
  • 2.1809
  • 2.1925
  • 2.6442
  • 2.9941
  • 2.4852
  • 1.8899
  • 2.2844

..**.................... 6804

  • 1. 9595
  • 1. 9497
  • 2 2613 1.7283
  • 2.C549
  • 1
  • 2.4504 *

.... 186 *

  • 2.2 1.9313
  • 2.1793
  • 1.8721
  • 2.3132
  • 2.1665
  • 3.6898
  • 9
  • 1.9829
  • 2.4101
  • 1.8311
  • 2.2629
  • 2.1241
  • 3.4922 *
  • 1.6899
  • 2.2492
  • 1.8498
  • 2.0838 *

...... 2.0100 *.........1 8569..*.2.8643 *

.......... 2.0263..*.1 6904......1 8787...

....1 6687

  • 1.7283 *
  • 2.5355
  • 3.8455
  • 10
  • 2.4430
  • 1.9374
  • 2.4008
  • 1.8963
  • 2.2375
  • 1.9267 2.1472
  • 1.8941
  • 2.4610
  • 3.5606
  • 2.2844
  • 1.8586
  • 2.2518
  • 1.8257
  • .2 0549......

1 6964........ 132...*.1 6607

  • 1.9280
  • 1 7094.. **. 2. 1367..*.2. 8921..*
  • 2.0 11
  • 1.8870
  • 2.1884
  • 1.9060
  • 2.3480
  • 1.9179
  • 2.3662
  • 2.3343
  • 4.3854
  • 2.2690
  • 2.2381
  • 4.0303 *
  • 1.8387
  • 2.0894
  • 1.8326
  • 2.1928
  • 1.8518 *

. 1.6804

  • 1.8821.*.1 6642..*..1.9564 *........1.6813..*.2.0126
  • 1.9485
  • 3.2677..*.
  • 1.8766
  • 2.2455
  • 1.9241
  • 2.3519
  • 2.1481
  • 3.0881
  • 12
  • 2.2556
  • 2.1809
  • 1.8343
  • 2.1517
  • 1.8564
  • 2.2376
  • 2.0547
  • 2.9145 *
  • 1.9
  • 1.8132
  • 2.4846 *

.... 595.*.1 6696......1 9298 '. 1 6836

  • 1 9901 1.9301
  • 2.3698
  • 2.1468
  • 3.0483
  • 4.6427
  • 13
  • 2.2042
  • 2.3149
  • 4.1272
  • 2.1925
  • 2.2636
  • 1.8952
  • 2.2707
  • 2.0533
  • 2.8524
  • 3.2935 *
  • 2.0093
  • 1.7094
  • 2.0126
  • 1.8122
  • 2.4341

..1.9497 2.1696

  • 2.5397
  • 2.3361
  • 3.0912
  • 4.6427
  • 14
  • 2.6734 2.9145
  • 4.1272 *
  • 2.6442
  • 2.1255
  • 2.4630
  • 2.2383
  • 1.8569 *
  • 1.9485
  • 2.4846
  • 3.2935
  • l

............. 2.1367

..... 13

  • 2.26 3.6977
  • 3.8502
  • 4.3916
  • 4 EFPD 118 % POWER 15
  • 3.1997 *
  • 3.4961
  • 3.5647
  • 4.0303
  • 200 EFPD lie t POWER 2.9941

... 4504...........

6

  • 2.8921.*.3.2642..* 405 EFFD 118 4
  • 2.
  • 2.865 PCWER I

1

]

APPENDIX Page 128 of 140 McGuire 2 Cylce 10 Core Operating Limits Report lnable 4 M-sub-C Values (F-sub-Q RPS Margin) - Power Escalation 1

AT 118% POWER, 4 EFPD, THIS IS LEVEL 18 OF 18 (LEVEL 18 s TOP OF CORE, LEVEL 1 = BOTTOM)

H G

B A

......................F.........E.........D.........C........................

8*

2.6242 2.1151 2.4884 2.0587 2.3543 2.3832 2.7223 3.2666 9*

2.1151 2.4689 2.0940 2.3323 2.0636 2.4557 2.3597 3.6270 10*

2.4884 2.0954 2.4627 2.0658 2.3901 2.1305 2.6792 3.8163 11*

2.0587 2.3340 2.0722 2.4535 2.0955 2.5103 2.5340 4.2841 12*

2.3543 2.0650 2.3937 2.0983 2.4624 2.3031 3.1137 13*

2.3832 2.4577 2.1320 2.5123 2.3024 3.0357 4.3591 14*

2.7223 2.3615 2.6814 2.5353 3.1149 4.3591 15

  • 3.2666 3.6312 1.8163 4.2876 AT 118% POWER, 4 EFPD, THIS IS LEVEL 17 OF 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 s BOTTOM)

H G

A

......................F.........E........D....*e...C........B

..*e........*.e 8*

2.0106 1.6513 1.8396 1.6562 1.7644 1.6673 1.9272 2.1313 9*

1.6513 1.7900 1.6413 1.7906 1.6251 1.7009 1.6844 2.5547 10*

1.0396 1.6462 1.8642 1.6502 1.7233 1.6292 1.8287 2.6085 11*

1.6562 1.7953 1.6537 1.8029 1.6282 1.7603 1.7073 2.9076 12*

1.7644 1.6256 1.7236 1.6299 1.7417 1.6355 2.1179 13*

1.6673 1.7014 1.6304 1.7617 1.6346 2.1279 2.9918 14*

1.9272 1.6859 1.8297 1.7082 2.1179 2.9946 15

  • 2.1313 2.5609 2.6120 2.9129 AT 110% POWER, 4 EFPD, THIS IS LEVEL 16 OF 18 (LEVEL 18 = TOP OF CORE. LEVEL 1 = BOTTOM)

..................................................................A....

H G

F E

D C

B 8*

1.9184 1.5262 1.7462 1.5256 1.6565 1.4929 1.7359 1.8455 9'

1.5262 1.6822 1.5236 1.6845 1.4580 1.5315 1.4762 2.2948 10*

1.7462 1.5285 1.7786 1.5092 1.5636 1.4486 1.6235 2.3096 11*

1.5256 1.6896 1.5145 1.6790 1.4473 1.5769 1.4646 2.5673 12*

1.6565 1.4587 1.5659 1.4488 1.5629 1.4317 1.8553 13*

1.4929 1.5315 1.4506 1.5785 1.4310 1.8931 2.6549 14*

1.7359 1.4777 1.6248 1.4650 1.8564 2.6563 15

  • 1.0455 2.2998 2.3130 2.5715 AT 118% POWER, 4 EFPD, THIS IS LEVEL 15 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 m BOTTOM)

H G

F E

D C

B A

8*

1.9484 1.5165 1.7618 1.4932 1.6397 1.4535 1.6983 1.7720 9'

1.5165 1.6942 1.5024 1.6644 1.4056 1.4901 1.4108 2.2423 10*

1.7618 1.5081 1.7866 1.4759 1.5285 1.3966 1.5608 2.2312 11*

1.4932 1.6696 1.4813 1.6634 1.3922 1.5315 1.3932 2.4855 12*

1.6397 1.4062 1.5307 1.3916 1.5166 1.3712 1.7894 13*

1.4535 1.4914 1.3985 1.5330 1.3706 1.8331 2.5873 14*

1.6983 1.4126 1.5630 1.3945 1.7905 2.5894 15

  • 1.7720 2.2471 2.2342 2.4894

APPENDIX Page 129 of 140 McGuire 2 Cylce 10 Core Operating Limits Report

' Table 4 (cont.)

M-sub-C Values (F-sub-Q RPS Margin) - Power Escalation AT 118% POWER, 4 EFPD, THIS IS LEVEL 14 0F 18 (LEVEL 18 = TOP CF CORE, LEVEL 1 = BOTTCM)

H G

F C

8 A

...............................E.........D.................................

8' 2.0723 1.5973 1.8668 1.5665 1.7256 1.5219 1.7796 1.8489 9'

1.5973 1.7911 1.5006 1.7481 1.4588 1.5538 1.4643 2.3534 10' 1.8668 1.5870 1.8880 1.5320 1.5846 1.4401 1.6193 2.3307 11*

1.5665 1.7539 1.5387 1.7347 1.4399 1.5853 1.4321 2.5806 12*

1.7256 1.4596 1.5870 1.4405 1.5787 1.4196 1.8570 13' 1.5219 1.5552 1.4420 1.5876 1.4190 1.9128 2.7L96 14*

1.7796 1.4664 1.6209 1.4328 1.8581 2.7119 15

  • 1.8489 2.3587 2.3342 2.5867 AT 118% POWER, 4 EFPD, THIS IS LEVEL 13 CF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 x BOTTOM)

........................................D.........C........B H

G F

E A

8*

2.2107 1.6736 1.9719 1.6312 1.8082 1.5004 1.8540 1.9024 9'

1.6736 1.8910 1.6483 1.8261 1.5075 1.6148 1.5101 2.4461 10*

1.9719 1.6552 1.9869 1.5875 1.6449 1.4839 1.6752 2.4216 11' 1.6312 1.8325 1.5947 1.8116 1.4839 1.6415 1.4666 2.6839 12' 1.8082 1.5089 1.6474 1.4846 1.6397 1.4624 1.9200 13*

1.5804 1.6165 1.4861 1.6432 1.4617 1.9872 2.8197 14' 1.0540 1.5123 1.6770 1.4673 1.9211 2.8219 15

  • 1.9024 2.4537 2.4235 2.6885 AT 118% PCWER, 4 EFPD, THIS IS LEVEL 12 0F 18 (LEVEL 18 : TCP OF CORE, LEVEL 1 = BOTTOM)

..........................................................,.........A......

H G

F E

D C

B 8'

2.4310 1.8220 2.1489 1.7601 1.9578 1.7044 2.0039 2.0440 9*

1.8220 2.0657 1.7843 1.9787 1.6247 1.7451 1.6213 2.6477 10*

2.1489 1.7926 2.1621 1.7220 1.7846 1.6054 1.8061 2.6125 11*

1.7601 1.9862 1.7297 1.9725 1.6062 1.7836 1.5841 2.9041 12*

1.9578 1.6255 1.7877 1.6087 1.7948 1.5920 2.0918 13' 1.7044 1.7460 1.6079 1.7846 1.5914 2.1768 3.0917 14*

2.0039 1.6238 1.8082 1.5849 2.0931 3.0947 15

  • 2.0440 2.6544 2.6147 2.9095 AT 118% POWER, 4 EFPD, THIS IS LEVEL 11 0F 18 (LEVEL 10 TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D C

B A

8' 2.6477 2.0031 2.3546 1.9441 2.1651 1.8817 2.2015 2.2272 9'

2.0031 2.2632 1.9738 2.1984 1.7967 1.9337 1.7864 2.8935 10' 2.3546 1.9826 2.3795 1.9036 1.9787 1.7711 1.9988 2.8855 11' 1.9441 2.2061 1.9130 2.1862 1.7721 1.9737 1.7443

. 2189 12*

2.1651 1.7978 1.9824 1.7752 1.9837 1.7541 2.3148 13*

1.8817 1.9361 1.7742 1.9750 1.7541 2.4105 3.4256 14*

2.2015 1.7885 2.0013 1.7462 2.3165 3.4293 15

  • 2.2272 2.9015 2 8908 3.2255

i 4

APPENDIX Page 130 0f 140 McGuire 2 Cylce 10 Core Operating Limits Heport l'able 4 (cont.)

M-sub-C Values (F-sub-Q RPS Margin)- Power Escalation AT 118% POWER, 4 EFPD, THIS IS LEVEL 10 OF 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

....H.........G........F.........E D

C B

A 8*

2.8209 2.1135 2.4985 2.0509 2.3182 2.0258 2.3777 2.3846 9*

2.1135 2.4013 2.0782 2.3267 1.9272 2.0876 1.9308 3.1200 10*

2.4985 2.0865 2.5245 2.0346 2.1372 1.9165 2.1666 3.1016 11*

2.0589 2.3354 2.0440 2.3423 1.9177 2.1474 1.8897 3.4747 12*

2.3182 1.9296 2.1416 1.9213 2.1666 1.9106 2.5266 13*

2.0258 2.0890 1.9189 2.1489 1.9095 2.6344 3.7124 14*

2.3777 1.9332 2.1696 1.8908 2.5286 3.7168 15

  • 2.3846 3.1293 3.1046 3.4824 AT 118% POWER, 4 EFPD, THIS IS LEVEL 9 0F 10 (LEVEL 18 : TOP OF CORE, LEVEL 1 = BOTTOM)

.................................................C........B.......A H

G F

E D

8*

2.8310 2.1383 2.5124 2.0809 2.3371 2.0350 2.4068 2.4602 9*

2.1383 2.4179 2.1035 2.3458 1.9368 2.0987 1.9441 3.1993 10*

2.5124 2.1121 2.5408 2.0561 2.1489 1.9201 2.1786 3.1863 11*

2.0009 2.3546 2.0671 2.3634 1.9213 2.1518 1.9142 3.5652 12*

2.3371 1.9381 2.1533 1.9248 2.1741 1.9177 2.5553 13*

2.0350 2.1015 1.9236 2.1547 1.9165 2.6679 3.8438 14*

2.4068 1.9466 2.1831 1.9165 2.5573 3.8438 15

  • 2.4602 3.2058 3.1896 3.5693 AT 118% POWER, 4 EFFD, THIS IS LEVEL 8 0F 18 (LEVEL 18 = TOP OF CORE, LEVEL 1 = BOTTOM)

H 0

F E

D C

B A

e................................**e........................e***.........

8*

2.6907 2.0070 2.3723 1.9490 2.1907 1.9114 2.2648 2.3032 9*

2.0070 2.2829 1.9713 2.2061 1.0296 1.9899 1.8339 2.9953 10*

2.3723 1.9801 2.3976 1.9332 2.0376 1.8242 2.0766 2.9896 11*

1.9490 2.2154 1.9405 2.2295 1.8263 2.0549 1.8263 3.3814 12*

2.1907 1.8306 2.0389 1.0296 2.0725 1.8296 2.4423 13*

1.9114 1.9925 1.0274 2.0562 1.8285 2.5470 3.6436 14*

2.2648 1.8371 2.0793 1.8285 2.4442 3.6478 15

  • 2.3032 3.0010 2.9925 3.3850 AT 118% POWER, 4 EFPD, THIS IS LEVEL 7 0F 18 (LEVEL 18 = TOP OF CORE, UNEL 1 : BOTTCM)

H G

F E

D C

B A

.*ee....................................................................e 8*

2.5245 1.8636 2.2015 1.8015 2.0328 1.7705 2,0981 2.1247 9*

1.8636 2.1242 1.8268 2.0522 1.6990 1.8490 1.6865 2.7671 10*

2.2015 1.8350 2.2263 1.7957 1.9010 1.6983 1.9184 2.7521 11*

1.8015 2.0603 1.8020 2.0876 1.7087 1.9254 1.7125 3.1285 12*

2.0328 1.7001 1.9022 1.7116 1.9762 1.7316 2.2912 13*

1.7705 1.8498 1.7001 1.9278 1.7306 2.4179 3.4144 14*

2.0981 1.6892 1.9207 1.7134 2.2929 3.4181 15

  • 2.1247 2.7720 2.7550 3.1322

APPENDIX Page 131 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1Dable 4 (cont.)

M sub-C Values (F-sub-Q RPS Margin)- Power Escalation AT 110% POWER, 4 EFPD, THIS IS LEVEL 6 0F 18 (LEVEL 10 = TOP OF CORE, LEVEL 1 e BOTTOM)

...............................E.........D.......C H

G F

B A

8*

2.3293 1.7235 2.0410 1.6704 1.8881 1.6433 1.9581 1.9962 9*

1.7235 1.9036 1.6923 1.9044 1.5728 1.7149 1.5803 2.5996 10*

2.0410 1.6999 2,0664 1.6630 1.7603 1.5720 1.7884 2.5779 11*

1.6704 1.9124 1.6695 1.9289 1.5762 1.7790 1.5833 2.9210 12*

1.8881 1.5744 1.7613 1.5792 1.8113 1.5912 2.1241 13*

1.6433 1.7161 1.5736 1.7000 1.5904 2.2335 3.1825 14*

1.9581 1.5826 1.7904 1.5847 2.1270 3.1851 15

  • 1.9962 2.60e0 2.5004 2.9246 AT 118% POWER, 4 EFPD, THIS IS LEVEL 5 CF 10 (LEVEL 18 s TOP OF CORE, LEVEL 1 = BOTTOM)

H G

F E

D B

A

.................................................C.......................

8*

2.1273 1.5629 1.8628 1,5236 1.7319 1.5004 1.8061 1.8378 9*

1.5629 1.7883 1.5366 1.7395 1.4318 1.5696 1.4435 2.4099 10*

1.8628 1.5443 1.8898 1.5138 1.6082 1.4298 1.6363 2.3786 11*

1.5236 1.7465 1.5205 1.7621 1.4311 1.6224 1.4373 2.6913 12*

1.7319 1.4331 1.6092 1.4338 1.6425 1.4398 1.9410 13*

1.5004 1.5711 1.4318 1.6241 1.4391 2.0374 2.9253 14*

1.8061 1.4455 1.6388 1.4387 1.9440 2.9281 15

  • 1.0378 2.4155 2.3822 2.6959 AT 110% POWER, 4 EFFD, THIS IS LEVEL 4 OF 18 (LEVEL 18 = TOP CF CORE, LEVEL 1 = BOTTOM)

.....................................................**............A....

H G

F E

D C

B 8*

2.0337 1.4960 1.7811 1.4653 1.6637 1.4466 1.7516 1.8006 9*

1.4960 1.7083 1.4731 1.6716 1.3821 1.5169 1.4017 2.3563 10*

1.7811 1.4809 1.0100 1.4557 1.5506 1.3789 1.5870 2.3281 11*

1.4653 1.6789 1.4620 1.6896 1.3802 1.5654 1.3929 2.6298 12*

1.6637 1.3839 1.5514 1.3826 1.5789 1.3882 1.8845 13*

1.4466 1.5183 1.3814 1.5663 1.3871 1.9701 2.8477 14*

1.7516 1.4036 1.5894 1.3942 1.8858 2.8503 15

  • 1.8006 2.3619 2.3315 2.6342 AT 118% POWER, 4 frPD, THIS IS LEVEL 3 0F 18 (LEVEL 18 = TCP OF 3, LEVEL 1 e BOTTOM)

...................................................................A.....

H G

F E

D C

B l

8*

1.9485 1.4310 1.7002 1.4061 1.5953 1.3995 1.7165 1.7865 9'

1.4310 1.6337 1.4061 1.5993 1.3407 1.4740 1.3731 2.3302 10*

1.7002 1.4131 1.7255 1.3984 1,5010 1.3395 1.5543 2.3043 11*

1.4061 1.6067 1.4042 1.6234 1.3412 1.5245 1.3719 2.6168 12*

1.5953 1.3418 1.5017 1.3437 1.5343 1.3560 1.8507 13*

1.3995 1.4755 1.3412 1.5268 1.3554 1.9381 2.8253 14*

1.7165 1.3749 1.5566 1.3731 1.8607 2.8278 l

15

  • 1.7865 2.3354 2.3077 2.6212 l

l

APPENDIX Page 132 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 4 (cont.)

M-sub-C Values (F-sub-Q RPS Margin)- Power Escalation AT 118% POWER, 4 EFPD, THIS IS LEVEL 2 OF 16 (LEVEL 18 m TOP OF CORE, LEVEL 1 BOTTOM)

............e..................E........D........C.......B.........A H

G F

8' 2.0012 1.4860 1.7491 1.4580 1.6424 1.4975 1.0544 2.0107 9'

1.4d60 1.6940 1.4477 1.6319 1.4256 1.5674 1.4929 2.5375 10*

1.7491 1.4551 1.7599 1.4565 1.5792 1.4284 1.6844 2.5458 11*

1.4580 1.6308 1.4628 1.6707 1.4290 1.6254 1.5271 2.9110 12*

1.6424 1.4276 1.5801 1.4330 1.6305 1.4750 2.0465 13*

1.4975 1.5609 1.4303 1.6280 1.4743 2.1017 3.1173 14*

1.0544 1.4950 1.6871 1.5286 2.0478 3.1173 15

  • 2.0107 2.5433 2.5499 2.9137 AT 118% POWER, 4 EFPD, THIS IS LEVEL 1 0F 18 (LEVEL 10 : TCP OF CORE, LEVEL 1 : BOTTOM)

......................P.........E........D.........C.........B.........A H

G 8*

2.6702 2.0032 2.4600 1.9064 2.2707 2.2268 2.7008 3.2325 9*

2.0032 2.4348 1.9511 2.2016 1.8913 2.3369 2.1887 3.7276 10*

2.4600 1.9573 2.4254 1.9158 2.2604 1.9465 2.5615 3.8849 11*

1.9064 2.2109 1.9255 2.3721 1.9375 2.3904 2.3502 4.4304 12*

2.2707 1.8959 2.2685 1.9438 2.3760 2.1701 3.1198 13*

2.2268 2.3386 1.9499 2.3941 2.1689 3.0795 4.6903 14*

2.7008 2.1918 2.5657 2.3600 3.1229 4.6903 15

  • 3.2325 3.7356 3.8897 4.4366 i

l 1

APPENDIX McGuire 2 Cylce 10 Core Operating Limits Report Table 5 F-delta-H/M-delta-H Values - Normal Operations AT 100% POWER, 4 EFPD

....H.........G.........F........E.........D C

B A

8*

.9680

  • 1.2790
  • 1.1050
  • 1.3070
  • 1.1860
  • 1.3310
  • 1.1090
  • 1.0380 *
  • 1 5403
  • 1.2026
  • 1.3793
  • 1.1515..*.1.2512..*.1.1115
  • 1.3069
  • 1.3739
  • 9
  • 1.2790
  • 1.1440
  • 1.3030
  • 1.1830
  • 1.3750
  • 1.2860
  • 1.3470 *.8280 *
  • 1.2026
  • 1.3348
  • 1.
  • 1.1583
  • 1.0905
  • 1.7186 *

..................... 1668

  • 1.2783
  • 1. 1024 10
  • 1.1050
  • 1.2970
  • 1.0930
  • 1.3150
  • 1.2620
  • 1.3750
  • 1.2150 *

.8310 *

  • 1.3793
  • 1.

1711................ 1660

  • 1.2192
  • 1.1432
  • 1. 2617 *
  • 1.3803
  • 1.

2..*

1.735 11

  • 1.3070
  • 1.1790
  • 1.3100
  • 1.1620
  • 1.3730
  • 1.2420
  • 1.3420 *

.7380 *

  • 1.1515..*. 1.2824
  • 1.1695
  • 1. 3194
  • 1. 1250
  • 1 2296
  • 1.1723..*.2 0175
  • 12
  • 1.1860
  • 1.3740
  • 1.2610
  • 1.3710
  • 1.2160
  • 1.3580
  • 1.0300 *

.......... 1. 1031

  • 1. 2199
  • 1.1265
  • 1.2298
  • 1. 1188
  • 1.4526
  • 1.2512
  • 13
  • 1.3310
  • 1.2840
  • 1.3740
  • 1.2400
  • 1.3580 *

.9920 *

.6800

  • 1.1115
  • 1.1590
  • 1.1441
  • 1.2308
  • 1.1180
  • 1.49

.................................................. 39

  • 2.1270...*

14

  • 1.1090
  • 1.3450
  • 1.2130
  • 1.3400
  • 1.0290 *

.6800 *

  • 1.3069
  • 1.0999
  • 1.2633
  • 1.1732
  • 1.4539
  • 2. 1270
  • 15
  • 1.0300 *

.8260 *

.8300 *

.7370

. 1.3739

  • 1.7226
  • 1.7374
  • 2. 0203..* M-DEL-H AT 100% POWER, 200 EFPD H

G F

D C

B A

...............................E..........................................

8* 1.0240

  • 1.3630
  • 1.1540
  • 1.3700
  • 1.1600
  • 1.2110
  • 1.0020 *

.9620 *

..... 91.*.1 1353

  • 1.3347
  • 1.1057
  • 1.2590
  • 1.2123
  • 1 4349
  • 1. 4731..*.
  • 1.46 9
  • 1.3630
  • 1.1890
  • 1.3770
  • 1.2010
  • 1.3710
  • 1.2090
  • 1.2600 *

.7550 *

  • 1 1353
  • 1.2925
  • 1.1151..*. 1.2592
  • 1.1017.................

1.2263

  • 1.1721
  • 1.0734
  • 10
  • 1.1540
  • 1.3730
  • 1.1570
  • 1.3670
  • 1.2350
  • 1.3540
  • 1.1190 *.7830 *
  • 1.3347
  • 1.1183 *

.................. 1.3136

  • 1.1232
  • 1.2366......................................

209

  • 1.8296 *
  • 1.1245
  • 1.3 11
  • 1.3700
  • 1.1970
  • 1.3630
  • 1.2020
  • 1.3820
  • 1.1980
  • 1.2350 *

.6880 *

  • 1.2632
  • 1.2773
  • 1.

. 1.1057

................. 1.1254 *.................. 1087

  • 1.2764
  • 1. 2286
  • 2.1176
  • 12
  • 1.1800
  • 1.3690
  • 1.2330
  • 1.3800
  • 1.1850
  • 1.3170 *

.9430 *

  • 1.2590
  • 1.1024
  • 1. 2386 *

........ 1102...*.1.2565

  • 1.1441.*.1.5797
  • 1.

13

  • 1.2110
  • 1.2080
  • 1.3530
  • 1.1870
  • 1.3180 *

.9370 *

.6800 *

  • 1. 2123
  • 1.2264
  • 1.1253
  • 1.2775
  • 1.1441
  • 1. 5753
  • 2.1543
  • 14
  • 1.0020
  • 1.2590
  • 1.1100
  • 1.2340 *

.9420 *

.6800 *

  • 1.4349
  • 1.1731
  • 1.3221
  • 1.2296
  • 1.5796
  • 2.1542
  • 15 *

.9620 *

.7540 *.7830 *

.6880

  • 1.4731
  • 1.8778
  • 1.0297
  • 2.1

............................... 178

  • M-DEL-H

c

~

l

.)

I APPENDIX Page 134 of 140 McGuire 2 Cylce 10 Core Operating Limits Report

{

'rable 5 (cont.)'

)

' F-delta H/M-delta-H Values - Normal Operations AT 100% POWER, 405 EFPD

....H.....**..;C.......F.........E.........D.........C.........B.........A......

8

  • 1.0090
  • 1.3300
  • 1.1230
  • 1.3470
  • 1.1450
  • 1.1600 *-.9900
  • 9860 *
  • 1. 4543..*. 1. 1566..*.1. 3411
  • 1 1174..*.1. 2711..*.1 2491..*. 1. 4395.*.1. 4637
  • 9
  • 1.3300
  • 1.1490
  • 1.3480
  • 1.1700
  • 1.3490
  • 1.1570
  • 1.2340 *.7820 *

'* 1. 1566

  • 1. 3070
  • 1 1321.*. 1. 2874..*. 1. 1177..*.1. 2611..*. 1. 19.93..*.1. 8064...*

10

  • 1.1230
  • 1.3450
  • 1.1390
  • 1.3400
  • 1.1910
  • 1.3160
  • 1.0900 *

.8170 *

  • 1 3411..*.1. 1346
  • 1 3051...*.1. 1375..*. 1.2795
  • 1. 1576
  • 1. 3675
  • 1.7475..*

11

  • 1.3470
  • 1.1680
  • 1.3440
  • 1.1780
  • 1 3410
  • 1.1390
  • 1.2050 * '.7170 *
  • 1. 1174.*.1. 2896
  • 1. 1399..*.1. 2753.*. 1. 1385
  • 1. 3000
  • 1. 2665.*.2. 0246.*.

12

  • 1.1450
  • 1.3490
  • 1.1900
  • 1.3400
  • 1.1330
  • 1.2650 *

.9370 *

  • 1. 2711 *.1. 1177
  • 1. 2006..*.1. 1397..*.1. 2839..*.1. 1901..*. 1. 5687.*.

13

  • 1.1600
  • 1.1580
  • 1.3160
  • 1.1390
  • 1.2650 *.9430
  • 7230 *

. 1 2491.*.1 2612.*. 1. 1578

  • 1. 3081..*.1. 1892..*.1. 5440..*.2.*.0017
  • 14 *.9900
  • 1.2340
  • 1.0900
  • 1.2050 *.9370 *.7230 *
  • 1. 4395..*.1. 1994.*. 1.3676.*. 1. 2665...*.1 5693
  • 2. 0017
  • 15 *

.9860 *

.7810 *

.8170 *

.7170

  • 1 4637
  • 1. 8064.*. 1. 7477
  • 2.0250
  • M-DEL-H AT 75% POWER, 4 EFPD H

C D

C B

A

......................F.........E......................***................

'8*

.9360

  • 1.2760
  • 1.1040
  • 1.3290
  • 1.2060
  • 1.3590
  • 1.1300
  • 1.0550 *
  • 1. 8706.*. 1. 494.9
  • 1 6433.*.1. 3638..*.1 4.741..*.1. 3007... 1. 5520.*.1 6329.*

l I

9

  • 1.2760
  • 1.1290
  • 1.3180
  • 1.1950
  • 1.3980
  • 1.3080
  • 1.3770 *.8390 *

. 1. 4949

  • 1. 6460
  • 1 4016.*.1 5277
  • 1. 3089
  • 1. 3584
  • 1. 2918
  • 2 0400
  • 10
  • 1.1040
  • 1.3120
  • 1.0980
  • 1.3300
  • 1.2760
  • 1.3970
  • 1.2330 *.8380 *
  • 1 6433..*. 1. 4070
  • 1. 6319
  • 1. 3934
  • 1.442.3
  • 1 3150..*.1. 4510
  • 2. 0669.*

.)

11

  • 1.3290
  • 1.1910
  • 1.3250
  • 1.1550
  • 1.3750
  • 1.2410
  • 1.3490 *.7300 *
  • 1.3638..*.1. 5289
  • 1. 3983
  • 1.6343.*. 1. 3875
  • 1.5140
  • 1.3955.*. 2. 3923
  • 12
  • 1.2060
  • 1.3960
  • 1.2740
  • 1.3720
  • 1.1100
  • 1.3170
  • 1.0180 *

'l J

  • 1. 4741.*. 1.3073
  • 1. 4433.*.1.3899
  • 1. 5139..*.1. 3758
  • 1. 8004..*.

13

  • 1.3590
  • 1.3060
  • 1.3950
  • 1.2390
  • 1.3180 *.9480 *.6650 *
  • 1. 3007
  • 1 3585..*.1. 3168
  • 1. 5164
  • 1. 3758..*.1. 8471.*. 2. 6584
  • 14
  • 1.1300
  • 1.3750
  • 1.2320
  • 1.3470
  • 1.0160 *.6640 *
  • 1. 5520..*.1.2936
  • 1. 4523
  • 1 3966
  • 1. 8020
  • 2. 6621
  • 15
  • 1.0550 *

.8370 *

.8370 *.7370

  • 1 6329
  • 2.0534..*.2 0694.*.2.3957
  • M-DEL-H I

l I

- ~. -

APPENDIX Page 135 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1Eable 5 (cont.)

F-delta-H/M-delta-H Values - Nomal Operations AT 75% POWER, 200 EFPD

....H.........G F

E D

C B

A 8*

.9640

  • 1.3640
  • 1.1640
  • 1.4100
  • 1.2110
  • 1.2420
  • 1.0230 *

.9790 *

. 1 7754

  • 1.3952...*.1.5757
  • 1. 3032
  • 1.4543.*.1 4100..*. 1 6753..*. 1.7728
  • 9
  • 1.3640
  • 1.1840
  • 1.4080
  • 1.2260
  • 1.4000
  • 1.2340
  • 1.2850 *

.7660 *

  • 1. 3952
  • 1.5832
  • 1.3307
  • 1. 4711..*. 1. 2977
  • 1 4342..*. 1. 3901.*.2. 2055
  • 10
  • 1.1640
  • 1.4040
  • 1.1760
  • 1.3950
  • 1.2550
  • 1.3790
  • 1.1360 *

.7900 *

  • 1 5757......1. 3344
  • 1. 5390
  • 1 3325
  • 1.4686
  • 1 3301
  • 1 5701
  • 2. 1799
  • 11
  • 1.4100
  • 1.2220
  • 1.3910
  • 1.2080
  • 1.3700
  • 1.1760
  • 1.2390 *

.6850 *

..................................... 1. 3622

  • 1.5746
  • 1.4801.*.2.5594
  • 1,3032
  • 1.4730
  • 1.3360
  • 1.5742
  • 12
  • 1.2110
  • 1.4060
  • 1.2520
  • 1.3660
  • 1.0640
  • 1.2530 *.9200 *
  • 1.4543
  • 1.2985
  • 1 4706
  • 1.3644
  • 1 5485
  • 1.4128
  • 1.9725
  • 1.2420
  • 1.2330
  • 1.3780
  • 1.1760
  • 1.2530 *

.8760 *

.6450

  • 13

. 1 4100

  • 1. 4352..*.1. 3302
  • 1.5763
  • 1.4117... 1.9611.*.2.7229.*

1.0230

  • 1.2840
  • 1.1350
  • 1.2380 *

.9190 *

.6450

  • 14 *
  • 1.6753
  • 1.3912
  • 1.5715
  • 1.4883
  • 1 9738
  • 2. 7255.*

15 *

.9790 *

.7650 *

.7890 *

.6850

  • 1.7728
  • 2.2108
  • 2.1828.*. 2.5629..*. M-DEL-H i

AT 75% POWER, 405 EFPD H

G F

E D

C B

A 8*

.9240

  • 1.3250
  • 1.1370
  • 1.4050
  • 1.1910
  • 1.2050
  • 1.0250
  • 1.0190 *
  • 1. 8041
  • 1. 4020
  • 1.5973
  • 1.2852.*.1 4838.*.1.4639
  • 1.7089
  • 1.7292
  • 9
  • 1.3250
  • 1.1450
  • 1.3920
  • 1.2000
  • 1.4010
  • 1.1930
  • 1.2780 *.8050 *

......................................................... 3956

  • 2.1728 *
  • 1.4020
  • 1.6129
  • 1.3125
  • 1.4849
  • 1.2869
  • 1.4834
  • 1 10
  • 1.1370
  • 1.3880
  • 1.1700
  • 1.3860
  • 1.2180
  • 1.3400
  • 1.1150 *

.8340

  • 1.5973
  • 1.3153
  • 1.5390
  • 1 3215
  • 1.4799
  • 1. 3465
  • 1.5912
  • 2. 1032
  • 11
  • 1.4050
  • 1.2060
  • 1.3830
  • 1.1880
  • 1.3240
  • 1.1220
  • 1.2090 *

.7180 *

................... 1.3248

  • 1.5511.*. 1.3911.*.1. 6348
  • 1. 4902
  • 2.4423
  • 1.2852
  • 1.4873
  • 12
  • 1.1910
  • 1.4010
  • 1.2170
  • 1.3220 *.9950
  • 1.1670 *.9020 *

........................................ 102

  • 1.4754
  • 2.0007
  • 1.4838
  • 1.2894
  • 1.4812
  • 1.3921
  • 1.6 13
  • 1.2050
  • 1.1940
  • 1.3490
  • 1.1220
  • 1.1680 *.8540 *

.6710 *

  • 1.4639
  • 1.4834
  • 1.3466
  • 1. 6349
  • 1.4743
  • 1.9838
  • 2.6064
  • 14
  • 1.0250
  • 1.2770
  • 1.1150
  • 1.2090 *.9020 *

.6710 *

................... 1.5912

  • 1.4983
  • 2.0007
  • 2.6063 *
  • 1.7089
  • 1.3967
  • 15
  • 1.0190 *

.8040 *

.8340 *

.7100

  • 1.7292
  • 2.1727
  • 2.1034
  • 2.4426
  • M-DEL-H

...e....

r APPENDDC Page 136 of 140 McGuire 2 Cylce 10 Core Operating Limits Report lnable 5 (cont.)

F-delta-H/M-delta-H Values - Normal Operations AT 5 0 % POWER, 4 EFPD H

O F

E D

C

....................................**...................B.........A......

8*

.9060

  • 1.2770
  • 1.1060
  • 1.3540
  • 1.2280
  • 1.3900
  • 1.1520
  • 1.0720 *

. 2. 4817

  • 1.9452.*.2. 2364

............... 1. 9613

  • 1. 7374
  • 2 0593
  • 2.2395...*
  • 1.8279
  • 9
  • 1.2770
  • 1.1250
  • 1.3360
  • 1.2100
  • 1.4220
  • 1.3310
  • 1.4090 *

.8510 *

  • 1.9452
  • 2.1518 *

................... 1. 8696

  • 2.0355.*. 1.7593
  • 1.8176
  • 1. 7554
  • 2.7620
  • 10
  • 1.1060
  • 1.3300
  • 1.1050
  • 1.3480
  • 1.2900
  • 1.4210
  • 1.2510 *

.8450

  • 2.2364
  • 1.8777
  • 2.2 191...*.1.8818
  • 1. 9431.*.1.8034
  • 1. 9914...*.2.8714...*

11

  • 1.3540
  • 1.2050
  • 1.3420
  • 1.1480
  • 1.3740
  • 1.2370
  • 1.3530 *

.7380

  • 1.8279
  • 2.0384
  • 1 8883
  • 2.1167
  • 1 8377
  • 1.9992
  • 1. 8496
  • 3. 3331.*.

12

  • 1.2200
  • 1.4200
  • 1.2890
  • 1.3720
  • 1.0510
  • 1.2690
  • 1.0010 *
  • 1.9613
  • 1.7578
  • 1.9458
  • 1 8409
  • 1. 9890
  • 1 8114
  • 2.3842
  • 13
  • 1.3900
  • 1.3300
  • 1.4190
  • 1.2350
  • 1.2690 *

.8990 *

.6380 *

  • 1.7374
  • 1.8189
  • 1.8047
  • 2.

.............................. 0009

  • 1 8102
  • 2.4356
  • 3.5452
  • 14
  • 1.1520
  • 1.4070
  • 1.2490
  • 1.3510
  • 1.0000 *.6380 *
  • 2.0593
  • 1.7591
  • 1.9946
  • 1.8509
  • 2.3864
  • 3.5451
  • 15
  • 1.0720 *

.8490 *

.8440 *

.7360

  • 2.2395
  • 2.7711
  • 2.8749
  • 3.3373..* M-DEL-H AT 50% POWER, 200 EFPD H

G F

E D

C B

A 8*

.9070

  • 1.3680
  • 1.1770
  • 1.4710
  • 1.2610
  • 1.2900
  • 1.0310 *

.9920 *

  • 2.3277
  • 1.7984
  • 2.0542
  • 1.6617
  • 1.8824
  • 1.8246
  • 2.1964
  • 2.3169
  • 4...........................................

9

  • 1.3680
  • 1.1830
  • 1.4450
  • 1.2650
  • 1.4670
  • 1.2760
  • 1.3260 *

.7780 *

  • 1.7984
  • 2.0459
  • 1.6937
  • 1.8973
  • 1 6629
  • 1. 8501
  • 1.0014
  • 2.9328
  • 10
  • 1.1770
  • 1.4420
  • 1.1560
  • 1.4370
  • 1.2870
  • 1.4240
  • 1.1650 *

.8060 *

..................... 0010..*.1.7174..*.1. 8710

  • 1.7207
  • 2.0116
  • 2.8947
  • 2.0542
  • 1.6983
  • 2 11
  • 1.4710
  • 1.2640
  • 1.4330
  • 1.2110
  • 1.3660
  • 1.1710
  • 1.2520 *

.6910 *

. 1 6617

  • 1.8986
  • 1.7219..*. 2.0262..*.1. 7553..*.2 0077
  • 1.8489
  • 3 2159.+.

12

  • 1.2610
  • 1.4670
  • 1.2840
  • 1.3610 *.9820
  • 1.1500 *.8920 *

.................................................. 17

  • 2.5511..*
  • 1.8824
  • 1.6635
  • 1.8706
  • 1.7584
  • 1.9799
  • 1.82 13
  • 1.2900
  • 1.2750
  • 1.4230
  • 1.1700
  • 1.1500 *

.7950 *.6020 *

  • 1.0246 + 1.8595
  • 1.7219..*. 2.0093
  • 1.8217
  • 2.5222..*.3.5442.*

14

  • 1.0310
  • 1.3250
  • 1.1640
  • 1.2510 *

.8910 *

.6020 *

  • 2.1964
  • 1.8034
  • 2.0130
  • 1.8502
  • 2. 5536
  • 3.5441..*

15 *

.9920 *

.7760 *.8050 *

.6910

  • 2.3169
  • 2.9376
  • 2.8984
  • 3.2160
  • M-DEL-H

APPENDIX Page 137 of 140 McGuire 2 Cylce 10 Core Operating Limits Report 1Dable 5 (cont.)

F-delta-H/M-delta-H Values - Normal Operations AT 50% PCWER, 405 EFFD H

G D

C B

A

......................F........E 8*

.8530

  • 1.3150
  • 1.1430
  • 1.4730
  • 1.2460
  • 1.2490 *.9940 *

.9880 *

  • 2.3105
  • 1.7905
  • 2. 0609.*. 1. 6481..*.1. 9149
  • 1.9069.*. 2 2538
  • 2. 3110
  • 9
  • 1.3150
  • 1.1300
  • 1.4100
  • 1.2480
  • 1.4670
  • 1.2420
  • 1.3170 *.8000 *

............ 0678

  • 1.6843
  • 1.9140
  • 1.6586
  • 1. 9259
  • 1. 0330.*. 2.9012
  • 1.7905
  • 2.

10

  • 1.1430
  • 1.4090
  • 1.0900
  • 1.4200
  • 1.2560
  • 1.4060
  • 1.1550 *

.8520 *

  • 2. 0689
  • 1 6890
  • 1 9875.*.1.7047
  • 1. 8953..*. 1. 6896
  • 2.0376
  • 2. 7923
  • 11
  • 1.4730
  • 1.2470
  • 1.4170
  • 1.1790
  • 1.3240
  • 1.1360
  • 1.2450 *

.7380 *

  • 1. 6401
  • 1.9155 *............... 1.7095
  • 2.0150
  • 1.7692
  • 2.0336
  • 1. 8579
  • 3.0732
  • 12
  • 1.2460
  • 1.4670
  • 1.2550
  • 1.3220 *

.9180

  • 1.1080 *

.8970 *

  • 1 9149
  • 1.6590
  • 1. 8936
  • 1.7717
  • 2. 0459
  • 1. 8794
  • 2 5244
  • 13
  • 1.2490
  • 1.2420
  • 1.4060
  • 1.1360
  • 1.1080 *

.7940 *.6460 *

............ 9243

  • 1. 6895.*. 2.0336..*.1. 8791..*. 2. 5427
  • 3.3991..*
  • 1.9069
  • 1

.9940

  • 1.3170
  • 1.1550
  • 1.2450 *

.8970 *

.6460

  • 14

................... 2. 0374

  • 1. 0577
  • 2.5242
  • 3.3.990.*
  • 2.2530
  • 1.8335
  • 15 *

.9880

  • 7990 *

.8520 *

.7390

. 2. 3110

  • 2.9047
  • 2 7922
  • 3.0701.* M-DEL-H 4

1

APPENDIX Page 138 of 140 McGuire 2 Cylce 10 Core Operating Limits Report Table 6 F-delta-H/M-delta-H Values - Power Escalation AT 100% POWER, 4 EFPD

........................................D........C.........B.........A H

G F

E 8*

.9650

  • 1.2795
  • 1.1050
  • 1.3000
  • 1.1870
  • 1.3320
  • 1.1110
  • 1.0400 *

.............. 26

  • 1 3793.*.1.1515.*. 1. 2512
  • 1 1115..*.1. 3069
  • 1. 3739.*.
  • 1.5403
  • 1.20.........

9* 1.2790

  • 1.1430
  • 1.3040
  • 1.1840
  • 1.3770
  • 1.2870
  • 1.3490 *

.8300 *

............ 3348

  • 1. 1668
  • 1. 2783
  • 1. 1024
  • 1.1583
  • 1.0985..*.1.7186 *
  • 1.2026
  • 1 10
  • 1.1050
  • 1.2900
  • 1.0940
  • 1.3160
  • 1.2620
  • 1.3760
  • 1.2160 *

.8320 *

  • 1. 3793
  • 1 1711
  • 1. 3803
  • 1.1660.*. 1. 2192..*.1. 1432..*.1. 2617
  • 1. 7352.*

11 + 1.3080

  • 1.1790
  • 1.3110
  • 1.1620
  • 1.3730
  • 1.2410
  • 1.3420 *

,7390 *

.................................... 23

  • 2. 0175
  • 1.2296
  • 1.17
  • 1.1515
  • 1 2824
  • 1. 1695
  • 1.3194
  • 1.1250
  • 12
  • 1.1870
  • 1.3750
  • 1.2610
  • 1.3710
  • 1.2070
  • 1.3540
  • 1.0290
  • 1031......1. 2199
  • 1. 1265
  • 1 2290
  • 1.1180
  • 1. 4526 *
  • 1.2512
  • 1.

13

  • 1.3320
  • 1.2860
  • 1.3750
  • 1.2400
  • 1.3550 *

.9890 *

.6870 *

......... 180

  • 1.4939
  • 2.1270 *

............................ 1. 2308

  • 1.1
  • 1.1115
  • 1.1590
  • 1.1441
  • 14
  • 1.1110
  • 1.3460
  • 1.2140
  • 1.3400
  • 1.0200 *

.6870 *

............... 9

  • 1.2633
  • 1. 1732..*. 1 4539
  • 2. 1270
  • 1.3069
  • 1.099....**.......

15

  • 1.0400 *

.8280 *

.8310 *

.7 3 7 0

+ 1.3739

  • 1. 7226
  • 1. 7374..... 2. 0203
  • M-DEL-H AT 75% POWER, 4 EFPD

........................................D.......**C........B....**...'A......

H G

F E

8*

.9530

  • 1.2770
  • 1.1020
  • 1.3160
  • 1.1930
  • 1.3430
  • 1.1160
  • 1.0400 *

................... 1. 6433..*.1 3638..*. 1 4741.*.1. 3007

  • 1.5520..*. 1. 6329
  • 1.8786
  • 1.4949
  • 9
  • 1.2770
  • 1.1350
  • 1.3090
  • 1.1890
  • 1.3880
  • 1.2970
  • 1.3620 *.8200 *

... 4949

  • 1. 6460
  • 1. 4016 + 1.5277
  • 1 3089
  • 1. 3584.*. 1.2918
  • 2 0488 *
  • 1 10
  • 1.1020
  • 1.3030
  • 1.0920
  • 1.3220
  • 1.2700
  • 1.3870
  • 1.2240 *.8290 *
  • 1 6433
  • 1.4070
  • 1.6319
  • 1.3934
  • 1.4423
  • 1 3158
  • 1. 4510
  • 2.0669
  • 11
  • 1.3160
  • 1.1830
  • 1.3160
  • 1.1610
  • 1.3790
  • 1.2460
  • 1.3500 *

.7350 *

  • 1.3638
  • 1.5289
  • 1.3983
  • 1. 6343
  • 1.3875
  • 1. 5140
  • 1.3955.*. 2.3923
  • 12
  • 1.1930
  • 1.3860
  • 1.2690
  • 1.3770
  • 1.1860
  • 1.3510
  • 1.0200 *

.............................***.... 139

  • 1.3758
  • 1.8004 *
  • 1.3073
  • 1.4433
  • 1.3899
  • 1.5
  • 1 4741 13
  • 1.3430
  • 1.2950
  • 1.3860
  • 1.2440
  • 1.3510 *

.9790 *

.6770 *

............................ 1.5164

  • 1.3758
  • 1 8471
  • 2.6584 *
  • 1.3007
  • 1.3585
  • 1.3168
  • 14
  • 1.1160
  • 1.3600
  • 1.2220
  • 1.3490
  • 1.0260 *

.6760 *

  • 1.5520
  • 1.2936.*.1.4523
  • 1.3966
  • 1.8020
  • 2.6621.*.

15

  • 1.0400 *

.8260 *

.8280

  • 7330
  • 1.6329
  • 2.0534
  • 2.0694
  • 2 3957
  • M-DEL-H

l I

APPENDIX t

l Page 139 of 140 McGuire 2 Cylce 10 Core Operating Limits Report l

l liable 6 (cont.)

F-delta-H/M-delta-H Values - Power Escalation 1

i 1

AT 50% POWER, 4 EFPD H

G F

E D

C B

    • .......................**..........A 8*

.9470

  • 1.2780
  • 1.0900
  • 1.3100 ' 1.1960
  • 1.3490
  • 1.1150
  • 1.0350 *

.................... 4

  • 1. 8379
  • 1.9613
  • 1 7374
  • 2.0593
  • 2.2395 *
  • 1.9452
  • 2.236
  • 2 4817 9
  • 1.2780
  • 1.1310
  • 1.3120
  • 1.1500
  • 1.3960
  • 1.3040
  • 1.3700 *

.8230 *

. 1. 9452

  • 2. 1518
  • 1.8696
  • 2.0355
  • 1.7593
  • 1. 8176
  • 1.7554
  • 2.7620
  • 10
  • 1.0900
  • 1.3060
  • 1.0900
  • 1.3250
  • 1.2750
  • 1.3960
  • 1.2290 *

.8230 *

  • 2.2364
  • 1.8777
  • 2.2191
  • 1.08.8
  • 1.9431
  • 1.8034
  • 1 9914
  • 2.8714
  • 11
  • 1.3200
  • 1.1850
  • 1.3200
  • 1.1610
  • 1.3870
  • 1.2510
  • 1.3590 *

.7290 *

. 1. 8279.*. 2. 0384.*. 1. 8883

  • 2.1167
  • 1 8377
  • 1.9992
  • 1 8496
  • 3.3331
  • 12
  • 1.1960
  • 1.3940
  • 1.2740
  • 1.384)
  • 1.1850
  • 1.3560
  • 1.0270 *
  • 1.9613
  • 1. 7578
  • 1.9458.*.1 8409 *....... 1. 9890
  • 1. 0114
  • 2. 3842..*

13

  • 1.3490
  • 1.3020
  • 1.3940
  • 1.250C
  • 1.3570 *

.9780 *

.6700 *

.......................................... 2..*. 2.4356

  • 3.5452.*.

1.7374

  • 1.0189
  • 1.8047
  • 2.0009
  • 1.010 14
  • 1.1150
  • 1.3680
  • 1.2270
  • 1.3570
  • 1.0270 *

.6690 *

  • 2.0593
  • 1.7591
  • 1.9946..*.1. 8509
  • 2.3864............ 3.5451.*

l 15

  • 1.0350 *

.8210 *

.8220 *

.7280

.'.2. 2395

  • 2.7711
  • 2.8749
  • 3.3373
  • M-DEL-H AT 30% POWER, 4 EFPD

...................................................................A.....

H G

F E

D C

B 8*

.9430

  • 1.2700
  • 1.0960
  • 1.3240
  • 1.1980
  • 1.3530
  • 1.1140
  • 1.0300 *

......... 13

  • 1. 7374
  • 2. 0593.*.2.2395.*.

1.96....

..... 17

  • 1 9452..*. 2. 2364.*.1. 8279 *
  • 2.48 9
  • 1.2700
  • 1.1200
  • 1.3160
  • 1.1930
  • 1.4030
  • 1.3090
  • 1.3770 *

.8100 *

..................... 8696

  • 2 0355..*.1. 7593
  • 1. 8176
  • 1.7554.*.2 7620
  • 1.9452
  • 2.1518
  • 1...........

.8100

  • 10
  • 1.0960
  • 1.3090
  • 1.0880
  • 1.3290
  • 1.2790
  • 1.4030
  • 1.2320
  • 2.2364
  • 1.8777
  • 2.2191
  • 1.8818
  • 1.9431
  • 1.8034
  • 1.9914
  • 2.8714
  • 11
  • 1.3240
  • 1.1880
  • 1.3240
  • 1.1610
  • 1.3930
  • 1.2560
  • 1.3650 *

.7250

  • 1.8377
  • 1.9992
  • 1.8496
  • 3.3331 *
  • 1. 0279
  • 2.0384
  • 1.8883
  • 2.1167 12
  • 1.1980
  • 1.4010
  • 1.2780
  • 1.3910
  • 1.1860
  • 1.3610
  • 1.0200 *

..................................... 1.9890

  • 1.8114.*. 2 3842 *
  • 1.9613
  • 1.7578
  • 1.9458
  • 1.8409
  • 13
  • 1.3530
  • 1.3070
  • 1.4010
  • 1.2540
  • 1.3620 *

.9770 *.6640 *

  • 1. 7374
  • 1.0189
  • 1 8047
  • 2.0009
  • 1.0102..*.2.4356
  • 3 5452
  • 14
  • 1.1140
  • 1.3740 ' 1.2300
  • 1.3640
  • 1.0260 *.6630 *

............... 1.*.1.9946

  • 1.8509
  • 2.3864
  • 3.5451.*
  • 2.0593
  • 1.759....................................

15

  • 1.0300 *

.8160 *

.8170 *

.7240

  • 2. 2395
  • 2.7711
  • 2.8749
  • 3.3373
  • M-DEL-H

. APPENDIX Page 140 of 140

)

McGuire 2 Cycle 10 Core Operating Limits Report i

1 Table 7 Maximum Allowable Radial Peak (MARP) Values X/L 1.1 Axial Peak 1.2 Axial Peak 1.3 Axial Peak 1.4 Axial Peak 1.5 Axial Peak Elev. (ft)

MARP MARP MARP MARP MARE 0.12 1.6054 1.6519 1.6981 1.7379 1.7749 1.20 1.6051 1.6512 1.6936 1.7351 1.7704 2.40 1.6032 1.6467 1.6870 1.7236 1.7338 3.60 1.6006 1.6414 1.6789 1.7118 1.6890 4.80 1.5969 1.6341 1.6673 1.6854 1.6413 6.00 1.5927 1.6245 1.6521 1.6353 1.5917 7.20 1.5864 1.6130 1.6265 1.5848 1.5378 8.40 1.5781 1.5956 1.5773 1.5327 1.4886 9.60 1.5655 1.5612 1.5208 1.4815 1.4399 10.80 1.5459 1.5152 1.4717 1.4292 1.3883 12.00 1.5133 1.4693 1.4274 1.3878 1.3500 X/L 1.6 AxialPeak 1.7 AxialPeak 1.8 Axial Peak 1.9 Axial Peak 2.1 AxialPeak Elev. (ft)

MARP MARP MARP MARP MARP 0.12 1.7601 1.7314 1.6688 1.6080 1.5636 1.20 1.7294 1.7045 1.6440 1.5862 1.5385 2.40 1.6822 1.6633 1.6062 1.5514 1.4981 3.60 1.6361 1.6156 1.5645 1.5149 1.4526 4.80 1.5908 1.5716 1.5212 1.4714 1.4115 6.00 1.5462 1.5284 1.4807 1.4334 1.3660' 7.20 1.4913 1.4766 1.4344 1.3920 1.3271 8.40 1.4450 1.4296 1.3880 1.3485 1.2824 9.60 1.4013 1.3882 1.3490 1.3126 1.2501 10.80 1.3526 1.3433 1.3081 1.2726 1.2091 12.00 1.3140 1.3078 1.2749 1.2443 1.1890 APPENDIX Page 140 of 140

_, _ _