ML20076J754
| ML20076J754 | |
| Person / Time | |
|---|---|
| Site: | Zimmer |
| Issue date: | 06/24/1983 |
| From: | Neylan A TORREY PINES TECHNOLOGY |
| To: | Dickhoner W CINCINNATI GAS & ELECTRIC CO. |
| References | |
| TPT:CG&E-015, TPT:CG&E-15, NUDOCS 8307060119 | |
| Download: ML20076J754 (3) | |
Text
!
l
'o )
Y PlNCIPAL STAFFi A
A/h :NF TORREY PINES TECHNOLOGY O/RA
~
,;c s j
gg l
PO Don 85608 A/PA
?AC San Diego, Cakfomia 92138 Tt:tephone: (619) 455 2654 Jgp
,-Q 3M ic A ce of GA Technologies Inc.
EMSF June 24, 1983 h
Project 2474 ML TPT:CG&E-015 OL FlLE Ag 9 60- M L Mr. W. H. Dickhoner President and Chief Executive Officer Cincinnati Gas and Electric Company 139 East Fourth Street Cincinnati, Ohio 45202
Dear Mr. Dickhoner:
Enclosed is the biweekly status report on our Independent Review of ZIMMER Project Management, covering the period June 4 through June 17, 1983 Copics of this report are being sent to the U.S. Nuclear Regulatory Commission in accordance with the " Protocol Governing Communications between CG&E and Independent Organizations Conducting Reviews or Audits under the Commission's Order," Docket No. 50-358.
If you have any questions regarding the contents of this report, plecse call me.
Sincerely, W
A.J. heylan Project Manager Enclosure Copies w/ Encl.
/J. G.
Keppler (NRC)
J. Lieberman (NRC)
J. H. Sniczek (NRC)
J. C. Stone (NRC)
W. J. Ward (NRC)
J. Williams, Jr.
(CG&E)
Director, Office of Special Cases (NRC)
Zimmer Project Inspector (NRC)
Zimmer Section Chief (NRC) sfh{
Zimmer Sr. Resident Inspector (NRC) 8307060119 830624 DR ADOCK 05000 pg
t INDEPENDENT REVIEW OF ZIMMER PH0 JECT MANAGEMENT BIVE2KLY STATUS REPORT 50. 4 FOR THE PERIOD ENDING JUNE 17, 1983 The status report below is in reference to the Torrey Pines Technology Program Plan, document number GA-C17044, Revision A,
" Independent Review of ZIMMER Project Management," dated May, 1983 During this period the TPT Review Team spent the first week working at the Zimmer site reviewing documents, conducting interviews, anl collecting data relevant to each task in the Program.
On June 10, the team returned to San Diego, where they have continued to review documents and initiate work on evalua-ting the data and preparing initial drafts of the task reports.
Attachment "A" lists the individuals who were interviewed during the week of June 10.
During the second week, some idividuals were also contacted by telephone for the answers to specific questions which came up from the the review of documents and/or the notes on interviews.
Such telephone conversations have been documented in accordance with NRC's protocol.
The count and identification was completed of all the documents cataloged by the review team during the visit to Zimmer which ended on June 10.
There were 2,794 documents from this visit which have been identified and are being reviewed.
As of June 17, a total of 7,252 manhours have been expended on this review of the Zimmer project management.
The volume of documents has been somewhat greater than anticipated and the project was approximately one week behind the Project Schedule given in the revised Program Plan.
t 9
2,.m.
.n aaw - m
~
'".~
Attachment A INDEPENDENT REVIEW OF ZIHMER PROJECT MANAGEMENT LIST OF PERSONS INTEHYIEWED DETWEEN 6/4 AND 6/10/83 CG&E Assigned to CG&E H. Sager R. Foshag (Midcolumbia)
J. Weissenberg S. Martin (Independent)
G. Ficke C.
Keller (Job Shopper)
G. Pecterton
)?. Ecce-(f/I)
D. Schulte M. Carpen'ter (GCA)
J. Flynn J. Buck (SAI)
J. Wald H. Brinkmann NRC B.
Culver W. Murry P. Gwynn K.
Chitkara F.
Christianson M. Threm R. Ehas Other D. Frederick M. Rulli L. Burton (Hartford St. Boiler)
F.
K. Pfeifer J. Kemper (Hartford St. Boiler)
M.
Kapp C. Allison 1 National Board of D. Stringer R. Holt Boiler and Pressure N
IV I
Vessel Inspection Kaiser C.K. Smith B.
D. Varchol R.
R. Bietsch S. Hoover s,
--