Text
_ _
- psa **%
..\\,
UMTED STATES
[
NUCLEAR REGULATORY COMMISSION a
E 1
wAsmotom, o, c. sonas DETROITEDISONCOMPAy FERMI-2 DOCKET NO. 50-341 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 72 License No. NPF-43
- 1. -
The Nuclear Regulatory Comission (the Comission) has found that:
A.
The application for amendment by the Mroit Edison Company (the licensee)datedMay 18, 1990, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act),
and the Comission's rules and regulations set forth in 10 CFR Chapter I; i
B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the.
Comission; C.
-Thereisreasonableassurance(1)thattheactivitiesauthorizedby this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted
-in compliance with the Comission's regulations; i
c D.
The. issuance of this. amendment will not be inimical to tie common defense and security or to the_ health _ and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51-of the Comission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifica-tions as indicated in the attachment to this license amendment and paragraph.
2.C.(2) of Facility Operating License No. NPF-43 is hereby amended to read as follows:
Technical Specifications and Environmental Protection Plan The Technical Specifications contained in Appendix A as revised through-Amendment No.
, and the Environmental Protection Plan contained in Appendix B,-are hereby-incorporated in the-license. Deco shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Flan, g825029s9jogoj p
ADOCK 05000343 PDR
. _ =.. _ _. _ - _ -. _
_ _ ~ - _ _ - _ _ _ _ -
r 2
3.
This license amendment is effective as of its date of issuance.
FOR THE NUCLEAR REGULATORY COMMIS$10N bh'h L. B. Marsh, Director Project Directorate 111 1 Division of Reactor Projects Ill/IV/V Office of Nuclear Reactor Regulation
Attachment:
Changes to the Technical Specifications Date of Issuance: August 1, 1991 V
h
(
B:
v
_~
.,-----m
ATTACHMENT TO L1 CENSE AMENDHENT NO. 72 FACILITY OPERATING LICENSE NO. NPF-43 DOCKET NO. 50-341 Replace the following pages of the Appendix "A" Technical Specifications with the attached pages. The revised pages are identified by Amendment number and contain a vertical line indicating the area of change. The corresponding overleaf pages are also provided to maintain document completeness.
REMOVE IN$rRT 3/4 3-47*
3/4 3-47*
3/4 3-48 3/4 3-48 3/4 3-49 3/4 3-49 3/4 3-50*
3/4 3-50*
70verleaf page provided to maintain document completeness.
No changes contained in these pages, j
l l
INSTRUMENTATION 3/4.3.7 MONITORING INSTRUMENTATION RADI ATION HONITORING INSTRUMENTAT10ii llMITING CONDITION FOR OPERATION 3.3.7.1 The radiation monitoring instrumentation channels shown in Table 3.3.7.1-1 shall be OPERABLE with their alarm / trip setpoints within the specified limits.
APPLICABILITY:
As shown in Table 3.3.7.1-1.
ACTION:
With a radiation monitoring instrumentation channel alarm / trip a.
setpoint-exceeding the value shown in Table 3.3.7.1 1, adjust the setpoint to within the limit within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> or declare the channel inoperable.
b.
With one or more radiation monitoring channels inoperable, take the ACTION required by Table 3.3.7.1-1.
c.
The provisions of Specification 3.0.3 and 3.0.4 are not applicable.
SURVfittANCE REOUIREMENTS 4.3.7.1 Each of the above required radiation monitoring instrumentation channels shall be demonstrated OPERABLE by the performance of the CHANNEL CHECK, CHANNEL FUNCTIONAL TEST and CHANNEL CAllBRATION operations for the conditions and at the frequencies shown in Table 4.3.7.1 1.
l-FERMI - UNIT 2 3/4 3 47
z.
TABLE 3.3.7.1-I b
RADIATION MONITORING INSTRUMENTATION c
5 MINIMUM CHANNELS-
-APPLICABLE ALARM / TRIP.
'INSTRtiMENTATION OPERABLE CONDITIONS SETPOINT ACTION 1.
Control Center Normal' 2.
1,2,3,5 and
- s 340 cpm 70 Makeup Air Radiation _
(s 5 mR/hr)'
Monitor 2.
Area Monitors a.
Criticality Monitors
- 1) New Fuel I
f 25mR/hrg 71 Vault s 20 mR/hr
,1 Y
- 2) Fuel Storage Pool 2
2 5 mR/hr 72 1
3 and s 20 mR/hr(a) b.
Control Room Direct I
At all times s 0.5 mR/hr(a) 73 Radiation Monitor N:a 5
.EF e
W w
a n
~m-
---en--.e,cw.-
e. -+
w, s
-4 i
TABLE 3.3.7.1-1 (Continued)
RADIATION MONITORING INSTRUMENTATION TABLE NOTATIONS
- When irradiated fuel is being handled in the secondary containment.
- With fuel in the new fuel vault.
- With fuel in the fuel storage pool.
.(a)Alarmonly.
ACTION STATEMENTS ACTION 70 -
a.
With one of the required monitors inoperable, place the inoperable channel in the downscale tripped condition within I hour; restore the inoperable channel to OPERABLE status within 7 days, or, within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, initiate and maintain o)eration of_the control room emergency filtration system in tie recirculation mode of operation, b.
With both of the required monitors inoperable initiate and maintain operation of the control room emergen,cy filtration system in the recirculation mode of operation within I hour.
ACTION 71 -
With the required monitor inoperable, perform area surveys of the monitored area with portable monitoring-instrumentation at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
ACT10N 72 -
a.
With one or more of the required monitors inoserable, perform area surveys of the monitored area with porta)1e monitoring instrumentation at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
b.
With both of the required monitors inoperable daring fuel movement, implement the preplanned alternate method of monitoring using a continuous monitor; otherwise, suspend fuel movement.
FERMI - UNIT 2 3/4 3-49 Amendment No. 72
m TABLE 4.3.7.1-1 RADIATION MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS s;
OPERATIONAL O
CHANNEL CONDITIONS FOR CHANNEL FUNCTIONAL CHANNEL WHICH SURVEILLANCE INSTRUMENTATION CHECK TEST CALIBRATION REQUIRED 1.
Control Center Makeup Air Radiation Monitor.
5 M
R 1, 2, 3, 5, and
- 2.
Area Monitors a.
Criticality Moniters
- 1) New Fuel Vault S
M R
f
- 2) Fuel Storage Pool S
M R
ff Y
b.
Control Room Direct E
Radiation Monitor S
M R
At all times
- With feel in the new fuel vault.
- With fuel in the fuel storage pool.
- When irradiated fuel is being handled in the secondary containment.
L e