TENNESSEE VALLEY AUTHORITY CHATTANOOGA. TENNESSEE 374ot 400 Chestnut Street Tower II August 19, 1983 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Dear Mr. Denton:

In the Matter of the

)

Docket No. 50-296 Tennessee Valley Authority

)

This letter is to inform you of TVA's decision to commence an orderly shutdown of unit 3 no later than September 6, 1983 for the purpose of inspecting piping for possible cracking as a result of Intergranular Stress Corrosion Cracking (IGSCC) in lieu of our presently scheduled November 11, 1983 shutdown.

In light of the increasing questions in the last few weeks and TVA's safety first policy, we believe it would be prudent to shutdown and inspect the unit to alleviate the doubts regarding piping integrity.

This decision is based on unit 3 not having any inspections which meet the intent of IE Bulletins 82-03 or 83-02. The extent of our proposed inspection on unit 3 has not yet been defined, however, we will stay in touch with NRC regarding the extent of the examinations and evaluation of the results.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, nager Nuclear Licensing t

d y of f

1983 M

Notary Public My Commission Expires cc:

U.S. Nuclear Regulatory Commission Region II ATTN: James P. C'Reilly, Regional Administrator 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30303 Mr. R. J. Clark Browns Ferry Project Manager U.S. Nuclear Regulatory Commission

[g 7920 Norfolk Avenue Bethesda, Maryland 20814 8308230277 830819 PDR ADOCK 05000296 B3-TVA 5OTH ANNIVERSARY G

PDR An Equal Opportunity Employer j

-.