s Public Servlee Company *f CUlorado 7

16805 WCR 19 1/2, Platteville, Colorado 80651 September 27, 1982 Fort St. Vrain 47 Unit No. 1 P-82419 Mr. George Kuzmycz Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, MD 20034

SUBJECT:

Radiochemical Analysis of the FSV Plateout Probe

Dear Mr. Kuzmycz:

In our letter dated October 25, 1979 (P-79247) we requested relief from SR 5.2.6 of the Fort St. Vrain Technical Specifications which involved delaying removal and analysis of the plateout probe. This temporary relief was granted.

The plateout probe was removed on November 9, 1981 and the probe was

+

sent to General Atomic Company for analysis.

Enclosed for your review is the findings of the plateout probe l

analysis, which demonstrates that concentrations of the key fission l

products I-131 and SR-90 are well below the limits permissible by

(

Technical Specifications.

I If you have any further questions on this matter, please contact me.

Very truly yours, i

W.

ar u

Manager, Nuclear Production Of DW/1 sb cc:

(with enclosure)

John T. Collins Regional Administrator NRC Region IV f

~ kl0080256 820927 cI' )

i I PDR ADDCK 05000267 P

PDR

_