ML20073M064
| ML20073M064 | |
| Person / Time | |
|---|---|
| Site: | Palisades |
| Issue date: | 03/29/1983 |
| From: | CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.) |
| To: | |
| Shared Package | |
| ML18051A390 | List: |
| References | |
| NUDOCS 8304210407 | |
| Download: ML20073M064 (15) | |
Text
-
3 1
CONSUMERS POWER COMPANY PALISADES PLANT 4
RADIOLOGICAL ENVIRONMENTAL MONITORING REPORT JANUARY THROUGH DECEMBER, 1982 i
t i
i i
i t
l i
8304210407 830329 14 Pages PDR ADOCK 05000255 R
PDR OC0383-0027B-NLO2
1 A.
RADIOLOGICAL 1.
INTRODUCTION The data obtained by an analysis of samples taken during 1982 was statistically analyzed at the 95% confidence level by the method described in Consumers Power Company internal procedures RSD-E-03.
The data was statically evaluated against two criteria. The first-is the critical level which indicates the analysis of samples taken from near sites are higher than those taken from remote control sites but the difference is not significant. The second is the detection level (two times the critical level) which indicates the minimum detectable difference has been exceeded. Doses to the public will be calculated if the detection level is exceeded.
2.
LISCUSSION AND INTERPRETAT' ION OF RESULTS a.
Air Samples Statistical analysis of the airborne particulate sampling results between near site and control sites did not exceed the critical level.
Control sites were often higher than the near plant sites.
No I-131 activity was reported above the minimum detectable level.
Analysis was done on 622 of the 636 required samples. Two samples had no flow and were not analyzed acd 12 samples were deleted because of sampling malfunctions where sample flow was estimated.
These missing analysis do not indicate a substan-tial reduction in the air sample program. The Technical Specification sensitivities requirements were met and no action levels were execeded.
These results are consistent with expected results based on actual plant effluents and site meteorology.
b.
Lake Water Statistical analysis between the site lake inlet and the South Haven treated drinking water showed the critical level was not exceeded for Gross Beta or tritium analysis results.
In addition, the South Haven analysis was compared with the Charlevoix drinking water and showed no difference above the critical level. The lake water outlet sample had tritium levels above the detection limit. This is consistent with i
l reported site effluents as tritium releases were made every l
month during 1982. These measured releases account for the observed concentrations within 25%.
IC0383-0013A-RS01 i
g These observations are consistent with expected results based upon the site effluent data. Technical Specification sampling and sensitivity requirements were met and no action levels were exceeded.
4 c.
Drinking Water See lake water and well water discussion.
d.
Well Water Statistical analysis between the site well supply and two off site locations showed the critical level was not exceeded. Two analysis at the State Park well location met or exceeded action level requirements of 10 pCi/l gross beta and the required gamma analysis was run. No detectable gamma activity was found in either sample. Location SP has been historically higher than the other two well locations.
Technical Specification sampling and sensitivities were met.
Ei_lh Problems with the milk sampling program indicated a special report was required by Technical Specification 6.9.3.2.
This was submitted on 2-28-83. Eight (8) near site samples and nine (9) control site samples were missed in 1982 until the program was corrected. The problems with missing samples are detailed in the special report and will not be repeated except as they affect statistical analysis. The missing control samples were not considered crucial as the Big Rock Point control sample could reasonably be used for our statistical analyses. At least two near site samples were analyzed each month except August when procedure inadequacies caused by the transfer of the analytical lab from Chicago, Illinois to Albuquerque, New hexico, allowed the samples to spoil and analyses could not be run.
Statistical analyses between near sites and control sites (including the Big Rock Point control) showed the critical l
level was not exceeded for Sr-90 and Cs-137 analysis.
I-131 was less than detectable for all samples. Sensitivities were greater than our procedural requirements but did not exceed Technical Specification requirements.
Samples data for Sr-90 and Cs-137 is consistent with 1981 analysis. Notwithstanding the missing samples, the sampling program analysis gives reasonable assurance that effluents did not result in exposure to the public in excess of 5% of 10 CFR 20 limits.
IC0383-0013A-RS01 l
3 f.
Sediment Statistical analyses for gross beta between near sites and the control site off South Haven Municipal Beach showed the criti-cal level was not exceeded. No detectable Sr-90 was reported and only one of six near sites showed a Cs-137 reading above the minimum detectable limit. This is consistent with histot-ical data and published environmental reports showing levels of Sr-90 and Cs-137 in Lake Michigan remaining from weapons testing.
g.
Organic - Fish and Crops The action limit for organic samples in Technical Specification 4.11.2 (50 pci) is not appropriate for organic type samples, so the listed analysis requirements to Technical Specification Table 4.11.2 are followed.
Fish sampling was added to the program this year. Sr-90 analysis ranged from.02 to.17 pCi/g (wet). Only one of six samples show Cs-137 above minimum detectable level (0.11 pCi/g 4
wet). This is consistent with levels published in environ-mental reports (Argonne Ecology Reports and Environmental Technology).
h.
Gamma Dose - TLD Both onsite and near site TLD analyses were evaluated against l
the control sites.
No monthly, quarterly or the annual anal-yses exceeded the critical limit. On site annual TLDs had a critical level of 3.7 mR/ year and near site annual TLDs had a
, critical level of 5.2 mR/ year. This is consistent with expected results based on reported effluents and meteorology and indi-cates that effluents did not exceed 5% of 10 CFR 20 limits.
Five of 216 on or near site monthly TLDs were missing and one of the 36 control sites samples was missing. Six of 73 on or near site quarterly TLDs and four of 18 on or near site annual TLDs were also missing. These missing samples do not indicate a substantial reduction in the gamma dose analysis program.
Technical specification analysis sensitivities were met.
IC0383-0013A-RS01 i
l page 1 of 4-TABLE PSD-E-03A Environmental Radiological Monitoring Program Summ.ary Palisades Nuclear Plant, Docket DPR-20 l
Van Buren County, Michigan, January 1, 1982 to December 31, 1982 Analysis and Lower Limit All All Nonroutine i
Medium or Total Number of o,f Indicator Location with Highest Control Reported P+thway Sampled Analyses Performed Detection (a)
Locations Annual Mean Locations Measurements (c)
Unit of Measurement LLD Mean(b)
Name Mean(b)
Mean(b)
Range (b)
Distance En Direction Range (b)
Range (b)
Air (pci/m )
Cross Beta 622 0.01 (454/463)
KZ 35 mi SE 3.8 (156/159)
None 3.3 (<1-25)
(1-7) 3.7 (41-10) 1-131 622 0.02 LID all N/A None Laka Water Cross Alpha 24 1.0 (1/24)
Discharge 1.3 None None (pC1/1) 1.2 (41-5)
(<1-5)
Gross Beta 36 1.0 (24/24)
Discharge 4.2 (11/12)
None 3.8 (1-7)
(2-7) 3.6(<1-8)
Tritium 36 100.0 (17/24)
Discharge 2200 (7/12)
None (4100-5900) 158 (4100-290)
None 1202 (<100-5900)
Drinking Water Cross Beta 1.0 (pci/1)
Control lake water and well water are drinking water supplies.
Tritium 100.0 Well Water Cross Beta 36 1.0 (9/12)
State Park (1 mi N) 5.3 (18/24)
None (pC1/1) 3.5 (<1-9)
(41-16) 4.0 (41-16) e.
Nominal Lcuer Limit of Detection (LLD) as defined in HASL-300 (Rev 8/73), pages D-08-01, 02, and 03.
b.
Mean and range include nondetectable measurements only. Fraction of detectable measurements at specified locations is indicated in parenthesis.
c.
Nonroutine reported measurements are defined in the Palisades Technical Specifications, Section 6.9.3.2.
IC0383-0013A-RS01 L.
~
i Pa p 2 cf 4 TABLE RSD-E-03A i
Environmental Radiological Monitoring Program Summary l
Palisades Nuclear Plant, Docket DPR-20 Van Buren County, Michigan, January 1, 1982 to December 31, 1982 i
Analysis and Lower Limit All All Nonroutine I
Medium or Total Number of of Indicator incation with Highest Control Reported f
P-thway Sampled Analyses Performed Detection (s)
Locations Annual Mean Locations Measurements Unit cf Measurement LLD Mean(b)
Name Mean(b)
Mean(b)
Range (b)
Distance & Direction Range (b)
Range (b)
Milk I-131 43
.5 (0/28) 0/15 Yes (pC1/1)
Sr-89 43 5.0 (0/28) 0/15 2/28/83 Sr-90 43 1.0 (42/43) of (5 mi SE) 7.5 (15/15) 2/28/83 5.5 (<1-23)
(3-23) 4.7 (1-14) i Ca-137 43 2-5 (15/43)
Qt (5 mi-SE) 8.5 (9/16) 2/28/83 5.8 (< 2-36)
(42-36) 4.5 (d2-9) i sa-La 140 43 1-5 (0/28)
NA (0/15) 2/28/83 Camma Exposure la (Monthly) 247 1.0 (211/211)
P-04-JS (3.5 at ESE) 12.4 (35/35)
None (mR/ Month) 11.0 (7.6-17.1)
(8.9-17.1) 11.2 (7.9-15.1)
(mR/ Quarter)
TLD (Quarterly) 78 (66/66)
P-05 PR (3 mi E) 20.3 (12/12)
None 18.0 (13.4-23.2)
(16.7-23.2) 18.5 (16.6-20.6) l TLD (Annually) 17 (14/14)
P-04-JS (3.5 mi ESE) 57.2 (3/3)
None 48.5 (42.2-57.2) 49.3 (45.0-52.2) i j
Crops Cross Beta 15 1.0 (13/15)
JS (3.5 mi ESE) Grapes 3.1 None None l
(pC1/g Wet) 1.8 (0.5-3.1)
N/A Sr-89 15 0.025 (0/15)
NA None None EL i
IC0383-0013A-RS01 L
Page 3 of 4
- TABLE RSD-E-03A Environmental Radiological Monitoring Program Sussiary Palisades Nuclear Plant, Docket DPR-20 Van Buren County, Michigan, January 1,1982 to December 31, 1982 Analysis and Iower Limit All All Monroutine Medium or Total Number of o(
Indicator Location with Highest Control Reported Psthway Sampled Analyses Performed Detection (a)
Locations Annual Mean Locations Measurements Unit of Measurement LLD Mean(b)
Name Mean(b)
Mean(b)
Range (b)
Distance & Direction Range (b)
Range (b)
Crops Sr-90 15 0.005 (0/15)
MA None None PDL Cs-137 15 0.08 (0/15)
.05 (0/15)
NA None None POL Sediment Cross Beta 8
1.0 (6/6)
South Haven (5 mi N) 15 (2/2)
None (pC1/g Dry) 12 (3-23)
(4-25) 15 (4-25)
Sr-89 8
0.025 (0/6)
NA (0/2)
None Sr-90 8
0.005-0.11 (0/6)
NA (0/2)
None Cs-137 8
0.08 (3/6)
Discharge 0.11 (0/2)
Nonc
.88 (<.08.13)
(0.9.13)
Other Capena 8
0.1
< LLD Aquatic (fish)
Cross Beta 6
1.0 (5/6)
Vicinity of plant discharge None None (pC1/g Wet) 1.1 (0.5-2.2)
Sr-89 6
0.025.05 (0/6)
Vicinity of plant discharge None None Sr-90 6
0.005 (6/6)
Vicinity of plant discharge None None
.09 ( 02.17)
Cs-137 6
.08 (1/6)
Vicinity of plant discharge None None
.085 (.08.11)
ICO383-0013A-RS01 N
Page 4 of 4-TABLE RSD-E-03A Environmental Radiological Monitoring Program Summaary Palisades Nuclear Plant, Docket DPR-20 Van Buren County, Michigan, January 1, 1982 to December 31, 1982 4
^
Analysis and Lower Limit All All Nontoutine Medium or Total Number of of Indicator Location with Highest Control Reported l
P-thway Sampled Analyses Performed Detection (s) locations Annual Mean Locations Measurements-Unit of Measurement LLD Mean(b)
Name Mean(b)
Mean(b)
Range (b)
Distance & Direction Range (b)
Ra"Se(b) i All ether Analyses Perfrrmed During Y2cr (specify)
Casuna analysis run on two state park well samples over 10 pC1/1 gross beta.
April sample 9 10 pC1/1 showed no gamma (<5 pCi/1 MDL) 5 September 916 pC1/1 showed no e,amma (<10 pCi/1 IOL) i f
I i
i IC0383-0013A-RS01
Page 1 of 2 Samplina Locatiana
~
Polised2s Nuclear Plcnt TABLE RSD-E-03B Sample
~
1 t
t 5
5 3
I u" uq i
n t t a
i Station Code Location 22 2-
.5 E
e a
d C
1 ST Palisades Nuclear Plant X
X X
X X
X X
2 TH Tower Hill Farms X
X X~
X RR 3, Coloma, Michigan 5 Miles SSE 3
HS Herbert Soderberg X
X X
RR1, Covert, Michigan 5 Miles SE 4
JS Jerry Sarno X
X X
X RR1, Covert, Michigan 3% Miles ESE i
5 PR Paul Rude X
X X
X RR1, Covert, Michigan 3 Miles E 6
RB Richard Bus X
X X
X RR3, South Haven, MI 4-3/4 Miles NE 7
SD F Sherman Dairy Farm X
X X
X South Haven, Michigan 7% Miles NNE 8
SP State Park X
X X
X 1 Mile N 9
TP Covert Township Park X
X X
X 1%- Miles S l
10 GR Grand Rapids, Michigan X
X X
i 55 Miles NNE 11 KZ Kalamazoo, Michigan X
X X
35 Miles SSE 12 DG Dowagine, Michigan X
X X
30 Miles SSE SH South Haven, Michigan X
X 5 Miles N GM Glenn Miller X
Rt 1 Box 20 l
Covert, MI KK Kenneth Kemp X
Rt 4 Box.32 South Haven, MI l
page 2 of 2 TABLE RSD-E-03B sample e
be ad 2
a*
5 i
s i
5 e*
a a
e i
s.:
a v.a i.-.
.3 Station Code Location
<a 2
x o
v; s
w GH Clen Hessey x
Rt 2 Box 94 Bangor, MI MC Constantine Dairy,
I Constantine, MI (45 miles S1 )
% Mile N of Site I
% Mile 5 of Site X
SD Hudsonville Dairy X
Burnips, MI (35 miles NE) d O
O h
i 4 4 6
,,n--
-,,-------,----,-,w---
,-e,
__,---.- --- ----, - - - - ~ - ~
PAllSADES PLANT RADIOLDCICAL ENVIRONMENTA1. SURVEILLA>8CE STATIONS n
SOUTH %
HAVEN ese i
t l
e I
t 4
i i
l See PALISADES PLANT O
i nI en Ot*
I J
l O
i em i
1 s
l f
Litte*O e ene sowmener f60 statione l
Og; *,*,* * '. '6 8.** 8=='= 858 5 f
awrse mas sutose 767 e**5E a' E I.'.s,Y.c.8 w
8 f
l e
8AA65 OO me6SS l
I Ot8 e
i 1
l
-- _ ____.______ _..~..,____.._ ___._.____.__.____. _,._,_
l TABLE RSD-E-03C I
PALISADES NUCLEAR PLANT l
JANUARY 1, 1982 TO DECEMBER 31, 1982 SAMPLING AND ANALYSIS SUfMARY Number of Samples Frequency Medium Description Location Collected Type of Analysis of Analysis Air Continuous at As identified on 622 Gross Beta, I-131 Weekly /12 Approx 1 CFM Table RSD-E-03B Lake 1 Gallon Intake, Discharge 24 Gross Beta, Gross Alpha, Tritium Monthly /1 Water Composite Drinking 1 Gallon South Haven 12 Gross Beta, Tritium Monthly /1 Water-Lake Composite Well 1 Gallon Site, TP, SP 36 Gross Beta Monthly /3 Water Grab Milk 1 Gallon
- SDF, GM, AK, KK' 31 1-131, Sr-89 and Sr-90, Cs-137 Monthly /4 Grab GH, MC, SD BaLa-140 Gamma Continuous As identified on 247 TLD Dose Monthly /21 Dose Table RSD-E-03B 78 Quarterly /21 17 Annually /21 Crops Grab JS, PR, RB, TH 17 Gross Beta, Sr-89 and Sr-90, When Cs-137, I-131 Available Sediment
. Grab Discharge, N & S Site 8
Gross Beta, Sr-89 and Sr-90, Semi-Boundary, 5 miles N Cs-137 Annually /4 Fish Grab Discharge, Intake 6
Gross Beta, Sr-89 and Sr-90, Semi-Cs-137 Annually
- AK replaced by GH in October, SDF replaced by KK in May, MC and SD were used alternately as control locations.
IC0383-0013A-RS01
4 l
Page 1 of 3 TABLE RSD-E-03D f
HIGH, IDW AND AVERACE CONCENTRATIONS FOR HINEST AVERACE SAMONC IDCATION
[
PALISADES NUCl2AR PLANT JANUARY 1, 1982 to December 31, 1982 Medium Type of Analysis (1),
Locaticn High Low Averate
}
Air Cross Beta KZ Kalamazoo 35 mi E 7.0 pCi/m 1 pCi/m 3.80 pCi/m i
1-131 LLD i
Lake Water Cross Beta Discharge 7 pCi/1 2 pC1/1 4.2 pC1/1 Gross Alpha Discharge 5 pCi/1 1 pC1/1 1.3 pC1/1 I
Tritium Discharge 5900 pCi/1 100 pCi/1 2200 pCi/c Drinking Wster Cross Beta See note on Table RSD-E-03A l'
Tritium See note on Table RSD-E-03A Well Water Cross Beta State Park (1 mi n) 16 pC1/1 1 pC1/1 5.3 pC1/1 (1)Ministan detectable level (MDL) = air, gross beta 0.01 pCi/m,1-1310.02 pCi/m ; water, gross beta 1.0 pCi/1, gross alpha 1.0 f'
pC1/1, H-3100 pC1/1; milk, I-1310.5 pCi/1, Sr-89 5.0 pct /1, gasma isotopic 1.0 pC1/1; crops and sediment, gross beta 1.0 pC1/g, l
Sr-89 0.025 pCi/g, Sr-90 0.005 pCi/g, gasuna isotopic 0.05 pC1/g; some samples may have higher N)Ls due to sample size.
(2) Samples collected monthly in season.
j I
(3)Tw samples per location.
j t
j (4)lncludes transit dose which averages approximately 6.4 mR/round trip.
I IC0383-0013A-RS01 i
I
Page 2 of 3 TABLE RSD-E-03D HIQl. LOW AND AVERACE CONCEPrrRATIONS FOR HIQlEST AVERACE SAMPLING LOCATION PALISADES NUCLEAR PLANT JANUARY 1,1982 to December 31, 1982 Mediten
,T,pe of Analysie(1)
Location Hish Low Averase Milk I-131 LLD all Sr-89 LLD all Sr-90 CM (5 mi SE) 23 pCi/1 3 pCi/1 7.5 pC1/1 1
Cs-137 CM (5 mi SE) 36 pCL/L 2 pCi/1 8.5 pC1/1 Bata-140 LLD all Casuna Dose (4)
TLD (Monthly)
PO-4 JS 3.5 mi ESE 17.1 8.9 12.4 t
TLD (Quarterly)
PO-5 PR 3 mi E 23.2 16.7 20.3 TLD (Yearly)
PO-4 JS 3.5 mi ESE 57.2 57.2 57.2 Crops (2)
Cross Beta JS-farm (3.5 ESE) 3.1 pC1/g 1 pCi/g 1.6 pC1/g Sr-89 LID i
Sr-90 JS-farm (3.5 mi ESE)
.06 pC1/g
.017 pCi/g
.026 pC1/g Cs-137 LLD Other Canuma LLD ICO383-0013A-RS01 l
4 s
1 Page 3 of 3 TABLE RSD-E-03D HICH, IDd AND AVERACE CONCENTRATIONS FOR HI3 TEST AVERACE SANPLING LOCATION PALISADES NUCLEAR PLANT JAhtJARY 1,1982 to December 31, 1982 i
Medium Type of Analysis (1),
Location High Low Average Sediment (3)
Gross Beta S. Haven Public Beach (5 mi N) 25 pC1/g 4 pCi/g 15 pCi/g Sr-89
<LLD i
Sr-90 North plant boundary
.010
<.008 009 i
< LLD Other Camas
< LLD Aquatic Cross Beta Fish caught within plant 2.2
<1 1.1 (fish only) discharge areas.
Sr-89 Fish caught within plant
< LLD discharge areas.
Sr-90 Fish caught within plant
.17
.02
.09 I
discharge areas.
Cs-137 Fish caught within plant
.11 4.08
.085 discharge areas.
i i
i i
IC0383-0013A-RS01 l