e 9fifG
- c. -
Southern California Edison Company "',y,,
EL. C' S AN ONOFRE NUCLE AR GENER A TING S T A TION
}
P.O. B O X 128 S AN C LEMEN T E. C A LIFORNI A 9J672 b
H.B. RAY YELEPHONE ST ATION M AN AGE R U.S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region V 1450 Maria Lane, Suite 210 Walnut Creek, California 94596-5368 Attention:
Mr. J.
B. Martin, Regional Administrator
Dear Sir:
Subject:
Docket Nos. 50-361 and 50-362 14-Day Follow-Up Reports Licensee Event Report No.83-022 (Docket 50-361)
Licensee Event Report No.83-029 (Docket 50-362)
San Onofre Nuclear Generating Station, Unita 2 & 3
References:
(1) Letter, H.B.
Ray (SCE) to R.H.
Engelken (NRC),
dated March 22, 1983 (2) Letter, H.B.
Ray (SCE) to R.H.
Engelken (NRC),
dated March 25, 1983 The referenced letters provided you with confirmation of our prompt notifications of reportable occurrences involving the use of Westinghouse Electric Corporation's gate valves in safety related systems.
Pursuant tc Sections 6.9.1.12.1 of Appendix A, Technical SpecificaLiais to Facility Operating Licenses NPF-10 and NPF-15 for San Onofre Units 2 and 3, respectively, this submittal provides the required 14-day follow-up report and copies of Licenseo Event Reports (LER's).
Enclosed LER 83-022 (Docket 50-361) and LER 83-029 (Docket 50-362) address these events.
It should be noted that Southern California Edison purchased a total of six (6) such valves to be installed in either Unit 2 or 3, however, only three (3) such valves were installed:
two (2) in Unit 2, and one (1) in Unit 3.
The remaining three (3) valves, purchased as spares, will not be installed until they are modified in accordance with vendor recommendations.
8304180414 830404 PDR ADOCK 05000361 S
PDR g.~G2 a3-is7