ML20073G242

From kanterella
Jump to navigation Jump to search
RO 83-026:on 830404,while in Mode 3,containment Isolation Valve 2HV8248 Declared Inoperable,Due to Maint Requirement. Valve Repaired.Cooldown Terminated.Followup Rept Will Be Submitted by 830418
ML20073G242
Person / Time
Site: San Onofre 
Issue date: 04/06/1983
From: Ray H
SOUTHERN CALIFORNIA EDISON CO.
To: Martin J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
RO-83-026, RO-83-26, NUDOCS 8304180215
Download: ML20073G242 (1)


Text

??fEh Southern California Edison Company,p, SU S AN ONOFRE NUC LE AR GENER A TING S T A TION

.f L'

t, p.o. sox iz a S A N C L EMEN T E. C A LIFOR NI A 92672 H. B. R A Y rettpsoNe April 6,1983 irar oN AN A...

,,i.,.,,,,oo V. S. Nuclear Regulatory Commission Office of Inspection and Enforcement Region V 1450 Maria Lane, Suite 210 Walnut Creek, California 94596-5368 Attention:

Mr. J. B. Martin, Regional Administrator

Dear Sir:

Su bject:

Docket No. 50-361 Prompt Reoort Licensee Event Report No.83-026 San Onofre Nuclear Generating Station, Unit 2 Pursuant to Section 6.9.1.12.b of Appendix A, Technical Specifications to Facility Operating License NPF-10, for San Onofre Unit 2, this submittal provides the written confirmation of our April 4,1983 discussion with the NRC Resident Inspectors of a reportable occurrence involving the Containment Isolation valves.

On April 4,1983 at 1345 while Unit 2 was in Mode 3, Containment Isolation Valve 2HV8248 (main steam relief header trap isolation valve) was declared inoperable.

Limiting Condition for Operation (LCO) 3.6.3 requires, among other things, the maintenance of at least one operable isolation valve in each penetration.

Since this requirement was not met, LC0 3.0.3 was invoked at 1440 and cooldown was initiated.

The valve was repaired and declared operable at 1600 at which time the cooldown was terminated.

A 14-day follow-up report and copy of Licensee Event Report (LER) No.83-026 will be sutxnitted by April 18, 1983 to address this event.

If there are any questions regarding the above, please contact me.

Sincerely, N[)'f2

)p[gy7g\\

cc:

A. E. Chaffee (USNRC Resident Inspector, Sar. Onofre Units 2 & 3)

R. J. Pate (USNRC Resident Inspector, San Onofre Units 2 & 3) 8304180215 030406 gDRADOCK05000g yq 83-IGO