I Millstone Nuclear Power Station, Unit No. 2 Proposed Revision to Technical Specifications and Request for Enforcement Discretion from the Action Statements r
for Limiting Conditions for Operation 3.6.1.1 and 3.6.1.2 l
l Marked-up Technical Specification Page.
i
.i i
I s
l
!.)
i I
f September 1994 i
l r
9410030343 940926 i
PDR ADOCK 05000336 P
(
i a C. H77-
~
i 1
CONTAINMENT SYSTEMS SURVEILLANCE RE001REMENTS (Continued) b.
If any periodic Type A test fails to meet.75 L. the test schedule for subsequent Type A tests shall be r$ viewed and approved by the Comission. If two consecutive Type A tests fail to meet.75 L, a Type A test shall be performed at least every 18 months until two consecutive Type A tests meet.75 L, at which time the above test schedule may be resumed.
c.
The accuracy of each Type A test shall be verified by a supple-mental test which:
1.
Confirms the accuracy of the Type A test by verifying that the difference between supplemental and Type A test data is within 0.25 L,.
2.
Has a duration sufficient to establish accurately the change in leakage between the Type A and the supplemental
(
20 test.
3.
Requires the quantity of gas injected into the containment or bled from the containment during the supplemental test to be equivalent to'at least 25 percent of the total measured leakage rate at Pa (54 psig).
l M
d.
Type B and C tests shall be conducted at Pa (54 psig) at cir locks.
- greater than 24 months except for tests involving intervals no e.
The combined bypass leakage rate shall be detemined to be <
0.017 L by appHeable Type B and C tests at least once per 24 months $xcept for penetrations which are not individually testable; penetrations not individually testable shall be determined to have no detectable leakage when tested with soap bubbles while the containment is pressurized to P, (54 psig) during each Type A test.
f.
Air locks shall be tested and demonstrated OPERABLE per Sur-veillance Reguirement 4.6.1.3.
bCEPT *1 HAT WE PEcoRHAnk.E. OF THE pc 3 m b TEuS 7HW WDr.E "DuE '5ETWEEaJ 7tanL1 ud SEPrsr48ea.1) j Ma,y Tt Oe.ptanto ro %C hc or 7MC Tun.pn4 1tEcu 04ANC.
- MILLSTONE - UNIT 2 3/4 6-3 ggngnq4 No.
y
i
\\
I 1
Docket No. 50-336 B14994 Millstone Nuclear Power Station, Unit No. 2 Proposed Revision to Technical Specifications and Request for Enforcement Discretion from the Action Statements for Limiting Conditions for Operation 3.6.1.1 and 3.6.1.2 Retyped Technical Specification Page September 1994
GONTAINMENT SYSTEMS SURVEILLANCE REQUIREMENTS (Continued) b.
If any periodic Type A test fails to meet.75 L.,
the test schedule for subsequent Type A tests shall be reviewed and approved by the Commission.
If two consecutive Type A tests fail to meet.75 L,,
a Type A test shall be performed at least every 18 months until two consecutive Type A tests meet.75 L, at which time the above test schedule may be resumed.
c.
The accuracy of each Type A test shall be verified by a supple-mental test which:
1.
Confirms the accuracy of the Type A test by verifying that the difference between supplemental and Type A test data i
is within 0.25 L.,
2.
Has a duration sufficient to establish accurately the change in leakage between the Type A and the supplemental test.
3.
Requires the quantity of gas injected into the containment or bled from the containment during the supplemental test to be equivalent to at least 25 percent of the total measured leakage rate at P. (54 psig).
r d.
Type B and C tests shall be conducted at P, (54 psig) at intervals no greater than 24 months except for tests involving i
air locks.*
I e.
The combined bypass leakage rate shall be determined to be <
0.017 L, by applicable Type B and C tests at least once per 24 months except for penetrations which are not individually testable; penetrations not individually testable shall be determined to have no detectable leakage when tested with soap bubbles while the containment is pressurized to P (54 psig) during each Type A test.
f.
Air locks shall be tested and demonstrated OPERABLE per Sur-veillance Reguirement 4.6.1.3.
i
- Except that the performance of the Type B and C tests that were due between June 2 and September 1, 1994, may be deferred to the end of the twelfth refueling outage.
MILLSTONE - UNIT 2 3/4 6-3 Amendment No. U,