OPERATING DATA REPORT OPERATING STATUS UNIT NAME.. 0YSTER CREFK 1.
DOCKET NUMBER.. 50-219 2.
UTILITY DATA PREPARED BY.
. M.J. MCFADDEN l.
(609) 971-4637 3.
REPORTING PERIOD... DECEMBER, 1982 4.
LICENSED THERMAL POWER (MWT).
1930 5.
NAMEPLATE RATING (GROSS MWE)
. 687.5 x 0.8 6.
DESIGN ELECTRICAL RATING (NET MWE).
. 650 7.
MAXIMUM DEPENDABLE CAPACITY (NET MWE)..
650 8.
MAXIMUM DEPENDABLE CAPACITY (NET MWE).
. 620 9.
IF CHANGES OCCUR ABOVE SINCE LAST REPORT, GIVE REASONS: NONE 10.
POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWE): 270 11.
REASON FOR RESTRICTION, IF ANY: FUEL DEPLETION MONTH YEAR CUMULATIVE 12.
REPORT PERIOD HOURS 744 8,760 114,168 13.
HOURS RX CRITICAL 551.9 5,636.8 83,613.2 14.
RX RESERVE SHUTDOWN HOURS 0
0 468.2 15.
HOURS GENERATOR ON-LINE 501.3 5,475.7 81,685.7 16.
UT RESERVE SHUTDOWN HOURS 0
0 0
17.
GROSS THERMAL ENER. (MWH) 481,700 6,787,700 135,378,730.5 18.
GROSS ELEC. ENER. (MWH) 135,470 2,126,300 45,812,275 19.
NET ELEC. ENER. (MWH) 124,540 2,013,090 44,080,528 20.
UT SERVICE FACTOR 67.4 62.5 71.6 21.
UT AVAIL. FACTOR 67.4 62.5 71.6 22.
UT CAP FACTOR (MDC NET) 27.0 37.1 63.4 23.
UT CAP FACTOR (DER NET) 25.8 35.4 59.4 24.
UT FORCED OUTAGE RATE 32.6 37.5 9.8 l
25.
FORCED OUTAGE HOURS 242.7 3284.3 8916.8 26.
SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION)*
REFUELING AND MAINTENANCE, 2/12/83, 11 MONTHS 27.
IF CURRENTLY SHUTDOWN, ESTIMATE STARTUP TIME:
N/A F304150531 830324 PDR ADOCK 05000219 R
- -