ML20073B566

From kanterella
Jump to navigation Jump to search
Proposed Tech Spec Section 4.14 Re Periodic Leak Test of Radioactive Matls Sources
ML20073B566
Person / Time
Site: Arkansas Nuclear 
Issue date: 04/18/1991
From:
ENTERGY OPERATIONS, INC.
To:
Shared Package
ML20073B563 List:
References
NUDOCS 9104240265
Download: ML20073B566 (2)


Text

.. _.

i 1

4 f

PROPOSED TECHNICAL SPECIFICATION CHANGES d

4 i

5 l

5 i

e 4

4 f

I i

d 9104240265 910418 PDR ADOCK 05000313 3

P PDR

.. ~ -..

H 4.14 RADIDACTIVE MATERIAL 3 SOURCES SURVEILLANCE Apo11 cab 111tv Applies to leakage testing of byproduct, bource, and speciel nuclear radioactive material sources.

Obiective To assure that leakage from byproduct, source, and special nuclear radioactive material sources does not exceed allowable limits.

)

Soccification Test for leakage and/or contamination shall be performed by the licensee or by other persons specifically authorized by the Commission or an agreement State, as follows:

1.

Each sealed source, except startup sources subject to core flux, containing radioactive material, other than flydrogen 3, with a half-life greater than 30 days and in any form other than gas shall be tested for leakage and/or contamination at intervals not to exceed six months.

2.

The periodic Icak test required does not apply to sealed sources that are stored and not being used. The sources excepted from this test shall be tnsted for leakage prior to any use or transfer to another user unless they have been leak tested within six months prior to the date of use or transfer.

In the absence of a certificate from a transferrer indicating that a test has been made within six months prior to the transfer, sealed sources shall not be put into use until tested.

3.

Each scaled startup source shall be leak tested within 31 days prior to being subjected to core' flux and following ' repair or maintenance to the source.

l l

4.

The periodic leak test does.not. apply to the borenometer source.

This source shall be tested for leakage at least once per 18 months.

Amendment No. J$, A$, $7, 110b

_,