PROPOSED TECilNICAL SPECIFICATION CilANGE UNIT 1 Y

g P

l

The annual radiolo,t cal environmental reports shall include i

summarized and tabulated results of all radiological environmental samples taken during the report period.

In the event that some results are not available for inclusion with the report, the report shall be submitted noting and explaining the reasons for the missing results.

The missing data shall be submitted as soon as possible in a supplementary report.

The report shall also include the following:

a summary description of the radiological environmental monitoring program including sampling methods for each sample type, size and physical characteristics of each sample type, sample preparation j

methods, analytical methods, and measuring equipment used; a map of all sampling locations keyed to a table giving distances and directions from one reactor; the result of Land Use Census required by the Specification 4.30.2, and the results of licensee participation in tbn Interlsberatory Comparison Program required by Specification 4.30.3.

6.12.2.6 Semiannual Radioactive Effluent Release Report **

(a) Routine radioactive effluent release reports covering the operation of the unit during the previous 6 months of operation shall be submitted within 60 days after January 1 and July 1 of each year.

(b) The radioactive effluent release reports shall include a summary of the quantities of radioactive liquid and gaseous effluents and solid waste release from the unit.

The data will be summarized on a quarterly basis following the format of Regulatory Guide 1.21, Revision 1.

l (c) The radioactive offluent release report shall include the following information for all unplanned releases to unrestrictea areas of radioactive material in gaseous and liquid effluents:

1.

A description of the event and equipment involved.

2.

Cause(s) for the unplanned release.

3.

Actions taken to prevent recurrence.

4.

Consequences of tbo unplanned release.

(d) This report shall contain a description of any changes to the ODCM and PCP mado during the period of the report.

    • A single submittal may be made for ANO-1 and ANO-2.

Amendment No. EE, 141a

9 e

e b

PROPOSED TECIINICAL SPECIFICATICN CHANGE UNIT 2 i

61}1MISTR_A.T1yE CONTRO.L 6.9.3.1 The radioactive offluent release report shall include a summary of the quantities of radioactive liquid and ganeous ef fluents and solid waste release from the unit.

The data will be summarized on a quarterly basis following the format of Regulatory Guide 1.21, Revision 1.

l 6.9.3.2 Any changes in the OFFSITE DOSE CALCULATION MANUAL and PCP shall be included in the semiannuni report for the period in which the change (s) was made effective.

6.9.3.3 The radioactive effluent release reports shall include the following information for all unplanned releases to UNRESTRICTED AREAS of radioactive materials in gaseous and liquid effluents:

1.

Description of the occurrence.

2.

Identify the cause(s) for exceeding the limit (s).

3.

Explain corrective actions taken to mitigate occurrence.

4.

Define action (s) taken to prevent recurrence.

S.

Summary of consequence (s) of occurrence.

6.9.3.4 The first report flied each year shall contain:

1.

A summary of the hourly meteorological data collected over the previous calendar year.

In lieu of including this summary in the report, the data may be retained by the licensee for NRC review and noted as such in the report.

2.

A summary of radiation doses due to radiological effluent during the previous calendar year calculated in accordance with the methodology specified in the OFFSITE DOSE CALCULATION MANUAL.

3.

The radiation dose to members of the public due. to their activities inside the site boundary.

This calculated dose shall include only those dose contributions directly attributed to operation of the unit and shall be compared to the limits specifled in 40 CFR 190.

6.9.3.5 The first report filed each year shall contain description of licensee initiated major changes to the radioactive waste systems (liquid, gaseous and solid) during the previous calendar year.*

  • This information may be included in the annual FSAR update in lieu of inclusion in this report.

ARKANSAS - UNIT 2 6-20 Amendment No. S,

l l