O TECHNICAL SPECIFICATION UNIVERSITY OF MISSOURI RESEARCH REACTOR FACILITY Number 3.3 Page 2

of 5

Date

SUBJECT:

Reactor Safety System (continued)

Pool Coolant Flow 2

1 0

425(4) gpm (Min) for each 50%

capacity heat exchanger leg or 2

2 0

850(4) gpm (Min) for one 100%

capacity heat exchanger Differential Pressure Across 2.52 psi (Min)

Reucctor 1

0 0

8.00 psi (Max)

Differential Pressure Across 0.63 psi (Min)

Reflector 0

1 0

2.00 psi (Max)

Differential Pressure Across Core 1

0 0

3200(5) gpm (Min)

Differential Pressure Across Core 0

1 1(2) 1600(5) gpm (Min)

Pressurizer Iligh Pressure 1

1 1(2) 95 psia (Max)

Pressurizer Low Level 1

1 1<2) 16 inches below centerline (Min)

Pool Level 0

0 1

23 feet (Min)

Primary Coolant Isolation Valves 507A/B Off Open Either valve Position 1

1 1(2)

Off Open Position Pool Coolant Isolation Valve 509 Off Open Valve 509 Off Open Position 1

1 0

Position Power Level Interlock 1

1 1

Scram as a result ofincorrect selection of operating mode Facility Evacuation 1

1 1

Scram as a result of actuating facility evacuation system Reactor Isolation 1

1 1

Scram as a result of actuating reactor isolation system 94o9130197 940902 PDR ADOCK 05000186 PDR p