ML20072R429

From kanterella
Jump to navigation Jump to search
Proposed TS 3.3,Page 2 of 5 Re Reactor Safety Sys
ML20072R429
Person / Time
Site: University of Missouri-Columbia
Issue date: 09/02/1994
From:
MISSOURI, UNIV. OF, COLUMBIA, MO
To:
Shared Package
ML20072R423 List:
References
NUDOCS 9409130187
Download: ML20072R429 (1)


Text

.

TECHNICAL SPECIFICATION O UNIVERSITY OF MISSOURI RESEARCH REACTOR FACILITY Number Page 2 3.3 of 5 Date

SUBJECT:

Reactor Safety System (continued)

Pool Coolant Flow 2 1 0 425(4) gpm (Min) for each 50%

capacity heat exchanger leg or 2 2 0 850(4) gpm (Min) for one 100%

capacity heat exchanger Differential Pressure Across 2.52 psi (Min)

Reucctor 1 0 0 8.00 psi (Max)

Differential Pressure Across 0.63 psi (Min)

Reflector 0 1 0 2.00 psi (Max)

Differential Pressure Across Core 1 0 0 3200(5) gpm (Min)

Differential Pressure Across Core 0 1 1(2) 1600(5) gpm (Min)

Pressurizer Iligh Pressure 1 1 1(2) 95 psia (Max)

Pressurizer Low Level 1 1 1<2) 16 inches below centerline (Min)

Pool Level 0 0 1 23 feet (Min)

Primary Coolant Isolation Valves 507A/B Off Open Either valve Position 1 1 1(2) Off Open Position Pool Coolant Isolation Valve 509 Off Open Valve 509 Off Open Position 1 1 0 Position Power Level Interlock 1 1 1 Scram as a result ofincorrect selection of operating mode Facility Evacuation 1 1 1 Scram as a result of actuating facility evacuation system Reactor Isolation 1 1 1 Scram as a result of actuating reactor isolation system 94o9130197 940902 PDR ADOCK 05000186 p PDR