l o

~

r o

UWNR Al[NUAL REPORT 1993-94 Page 13 of 16 Proceedings of the First Egyptian-Italian Conference on the Geosciences and Archaeology in the Mediterranean Countries.

R. Rothe, and G.Rapp, Jr.,

" Trace-Element Analyses of Egyptian Eastern Desert Tin and Its Importance to Egyptian Archaeology."

TABLE 1 LIQUID WASTE TO SANITARY SEWER DATE 9-21-93 1-26-94 5-25-94 TOTAL Total pCi 46.73 23.59 0

70.32 Gallons 800 8S0 1600 3250 Co-60 MPC USED 3E-5 pCi 4.29 4.19 0

8.48

  1. Ci/ml 1.42E-6 1.30E-6 0

6.89E-7 Fraction of MPC 4.73E-2 4.35E-2 0

2.30E-2 Mn-54 MPC USED 3E-4 pCi 5.67 2.92 0

8.59 4C1/ml 1.88E-6 9.08E-7 0

6.98E-7 Fraction of MPC 6.25E-3 3.03E-3 0

2.33E-3 Zn-65 MPC USED SE-5 pCi 36.77 16.48 0

53.25 i

pCi/ml 1.21E-5 5.12E-6 0

4.23E-6 i

Fraction of MPC 2.43E-1 1.03E-1 0

8.67E-2 Total Fraction of MPC 2.97E-1 1.49E-1 0

1.12E-1 Avg. concentration at point of release to sewer = 5.72E-6 pCi/ml Avg. fractiongif release limit without dilution = 1.12E-1 j

Max. fraction of release limit without dilution = 2.97E-1 1

Average daily sewage flow for dilution = 2.37E4 gallons j

Fraction of daily release limit including dilution = 4.90E-3 i

Average yearly concentration = 2.15E-9 4Ci/ml i

9409120199 940525 PDR ADOCK 05000156 R