Text
_...
POWER AUTHORITY OF THE STATE OF NEW YORK 10 CoLUMaus CtRcLE NEW YORK. N. Y.10019 (212) 397.6200 LE RO Y
$ CLAIR oesmatemo oe r ec.m TRUSTEES dOHNS.DYSON In e aDas me YeaTava GEORGE L ING ALLS JOSEPH R.SCH DER vece seemenneag RICH ARD M. FLYNN March 30, 1983 ROSERT i. uiLLONz' JPN-83-27
' ".".' "o n'.,"cM es......e.
& oneesmas cowm.s6 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Attention:
Mr. Domenic B. Vassallo, Chief Operating Reactors Branch No. 2 Division of Licensing
Subject:
James A. FitzPatrick Nuclear Power Plant Docket No. 50-333 Proposed Changes to the Technical Specifications Regarding MCPR Operating Limits Dear Sir Enclosed for filing are three (3) signed originals and nineteen (19) copies of a document entitled, " Application for Amendment to Operating License," together with forty (40) copies of Attachments I and II thereto comprising a statement of the proposed changes to the Technical Specifications and an associated Safety Evaluation.
The proposed Technical Specification changes alter the table of values specifying Minimum Critical Power Ratio (MCPR) operating limits for incremental cycle core average exposure in Section 3.1.B.l.
Accordingly, Figures 3.1-2 a, b, and c, depicting MCPR operating limit versus scram time ratio, are revised to reflect the new limits.
These changes correct the original Cycle 5 MCPR limits, which were found to be slightly non-conservative for pressurization transients due to the use of an improper carryunder fraction by General Electric Company in its input data for the ODYN computer code.
The proposed changed pages are Attachment I to the Application for Amendment enclosed with this letter, while the associated Safety Evaluation is Attachment II.
tt D
0 0
F304040420 830330 Y k\\
PDR ADOCK 05000333 R
P PDR
1 j
l The Authority has. classified this Application for Amendment as Class III, since the proposed changes involve a single safety issue.
Enclosed is a check for 84,000.00 as the amendment fee required by 10 CFR 170.22, which the Authority pays under protest pending a final determination of the legality of the fee schedule.
If you have any questions regarding the proposed changes, please contact Mr. J. A. Gray, Jr. of my staff.
Very truly yours,
(
J,. ' P.
ayn xecutive Vice President Nuclear Generation cc: Mr. J. Linville Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 136 Lycoming, New York 13093
~, -....