ML20072L460

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 80-13, Cracking in Core Spray Spargers. No Cracking Observed in Spargers or in in-vessel Piping During 1983 Maint/Refueling Outage Insp
ML20072L460
Person / Time
Site: Hatch 
Issue date: 06/24/1983
From: Gucwa L
GEORGIA POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-SSINS-6820 IEB-80-13, NED-83-365, NUDOCS 8307140058
Download: ML20072L460 (1)


Text

Georgia Power Company 333 Piedmont Avenue At!anta, Georgia 30308 Telephone 404 526 6526 PJarhng Address:

USNRC RE~'MN 'I Post off.ce Box 4545 g g f, g fy j dQ RGi A Atlanta, Georg:a 30302 Georgia Power 0b L. T. Gucwa rno sautten *sxtre system Chief Nuclear Engineer Power Generation Department NED-83-365 June 24, 1983 U. S. Nuclear Regulatory Commission

REFERENCE:

Office of Inspection and Enforcement RII: JPO Region II - Suite 2900 50-366 101 Marietta Street, NW I&E Bulletin Atlanta, Georgia 30303 80-13 ATTENTION: Mr. James P. O'Reilly GENTLEMEN:

Pursuant to the requirements of WC I&E Bulletin 80-13, " Cracking In Core Spray Spargers," please be advised that a visual inspection was performed on the Hatch Unit 2 Core Spray spargers and associated piping during the 1983 maintenance / refueling outage.

Using remote underwater television cameras (with the required viewing in situ of 0.001 inch diameter fine wires), no cracking of the Core Spray spargers or in-vessel piping was observed.

Should you have any questions in this regard, please contact this office.

Sincerely yours, 8f G*~*

L. T. Gucwa JAE/mb xc:

J. T. Beckham, Jr.

H. C. Nix, Jr.

Senior Resident Inspector EC Office of Inspection and Enforcement Division of Reactor Operations Inspection (Washington) 8307140058 830624 PDR ADOCK 05000366 1

O PDR 50 TEII

.