h DUQUESNE LIGHT COMPANY BEAVER VALLEY POWER STATION UNIT NO.1 Environmental Qualification Documentation Report for NRC SER 90 Day Response 1983 S So0!K o!Soo p
1
l l
O TABLE OF CONTENTS DESCRIPTION SECTION 1.
INTRODUCTION I
2.
METHODOLOGY USED FOR EVALUATIONS II 3.
EXECUTIVE
SUMMARY
III 4.
EVALUATIONS IV O
3 i
1 i
l lO I5 l
203.14.9 i
,_----___ =..- - _
I. INTRODUCTION O
1.0 Purpose of This Report This document is submitted to the NRC for the Duquesne Light Company (DLC) Beaver Valley Power Station Unit #1 as the 90-Day
)
Response to the NRC SER of December 16, 1982.
Because previous i
submittals provided to the NRC have contained large amounts of information, no attempt has been made in this submittal to g
transmit the same material again.
This report is intended to provide a qualification program information update to the NRC of what has been completed and what actions are being instituted for the future.
2.0 Scope of Review Only the equipment items that were identified on the October 15,
- 1981,79-01B Master List have been addressed in this resubmittal.
The recent NRC SER Review had assigned various
)
equipment item evaluation categories as identified below:
I.a Equipment Qualified I.b Equipment Qualification Pending Modification
)
II.a Equipment Qualification Not Established II.b Equipment Not Qualified II.c Equipment Satisfies All Requirements Except Qualified Life or Replacement Schedule Justified III.a Equipment Exempt From Qualification Review III.b Equipment Not in The Scope of The Qualification Review IV.
Documentation Not Made Available All of the original plant equipment has been responded to in this submittal; with.the exception of those in Sections I.a,
'III.a and"ISI;b of"tNU NRC SER revi'ew.'
^
?
1
-3.0 Overview of Report Contents O
This document is divided into four sections.
Section I,
" Introduction" defines the intent and scope of this report.
Section II,
" Methodology Used for Evaluations" provides a discussion on the methods and assumptions employed for the evaluation process.
Only equipment items originally included in the 79-01B October 15, 1981 Submittal have been reviewed in this report.
Documentation for those equipment items that were replaced, modified, added, or removed since October 15, 1981 Submittal, are not a part of this report but are maintained in the Duquesne Light Company Equipment Qualification File.
Section III is the
" Executive Summary" that includes an overview of the response in a
tabulated form providing a
comparison between the DLC review and the NRC reviews.
It contains a
summary status and the planned action for qualification for each item.
)
Section IV includes the review sheets for all equipment items listed as Categories I.b, II.a, and II.c in the SER.
The SER did not identify any equipment as belonging in Category II.b.
The System Component Evaluation Worksheets (SCEWS) have not been
?
included in this submittal because they had been issued to the NRC previously in the October 15, 1981 Submittal.
2 O
~
)
2 r
II. EVALUATION METHODOLOGY AND PROGRAM SPECIFICS
1.0 Background
The evaluation process used to assign a final qualification status to each equipment item included the investigation of all the previous reviews performed on that item since the 79-01B Submittal of October 15, 1981.
The equipment items of 79-01B submittal have been reviewed three times since their original submittal.
The initial review was performed by Duquesne Light Company, the second review and independent assessment by EDS, Nuclear, and the third review by Franklin Research Center.
2.0 Evaluation Structure The findings of these previous reviews are noted in Sections 3.0 A,B & C of each Tab in this report and the result of the current review performed is listed in Section 3.0 D.
Section 1.0 of the format contains equipment identification information.
)
A brief overview of the current status of each equipment item is noted in Section 2.0.
In Section 4.0, a comparison of the qualification category assigned by both the recent NRC and DLC f
review is presented.
In the event of a difference in the NRC and DLC evaluations, an explanation has been provided.
Section 5.0 of the Review Sheets provides a discussion and proposed action on all deficiencies / concerns raised by the NRC Review.
In some cases, reference is made to Duquesne Light Company's Equipment Qualification Files.
g In some of the tabs, the final section if required, is an Action Plan to qualify each equipment item by either replacement, modification, testing, relocation, analysis, or other means.
\\
l
3.0 Program Review To Date I
O The current DLC review of the 79-01B October 15, 1981 Submittal indicates a
number of changes of qualification categories assigned to equipment items as compared to the NRC review.
There are presently 14 items believed to be qualified by DLC in Category I.a instead of 5 items as evaluated by the NRC.
The number of equipment items in Category I.b
" Equipment Qualification Pending Modification" has reduced from 40 to 35 while Cat.
II.a " Equipment Qualification Not Established" is reduced to 9 from 30.
The equipment items which require the most attention, those in categories I.b and II.a, have decreased in number from 70 to 44.
This information is presented in summary form in Table I at the end of this section.
4.0 Service Conditions The environmental service conditions used for this evaluation are the same ones listed in 79-OlB October 15, 1981 Submittal.
The FSAR value for the chemical concentration is 15000 ppm, Boric Acid solution, and a lower value of Boric Acid solution was utilized for qualification testing purposes.
This was noted as qualification deficiencies.
An analysis for the resulting pH for various Boric acid concentrations does not indicate any significant change in the pH value.
The actual pH values changed by 3.9% and 3.5% when the Boric acid concentration was doubled for NaOH concentration of 0.1 wt.
% and 0.2 wt.
% respectively.
Hence, the different concentrations of Boric acid would have minimal difference in the resulting pH value.
5.0 Changes in Equipment Since 79-01B Oct. 15, 1981 Submittal Equipment items which have been replaced, modified, or added since October 15, 1981 Submittal are not included in this report.
They will be listed in the 90-Day Response to the NRC Rulemaking
?
by May 20, 1983.
2 c
6.0 Walkdown Report for Qualification Integrity of Safety-Related Electrical Equipment A physical walkdown was conducted at Beaver Valley Unit #1 to review the installation mounting, location, and traceability of j
the installed equipment to.what was reported.
Experienced groups of personnel from Duquesne Light company participated in the surveys conducted in the first half of 1982.
The survey contained physical inspections and photographing of pull boxes, equipment supports and attachments, solenoid
- valves, penetrations, transmitters, limit switches, etc.
The walkdown was corducted in the areas of the reactor containment, safeguards, primary auxiliary
- building, diesel generator building and the auxiliary feed pump area.
7.0 Program Specifics A.
Equipment Replaced During 2nd Refueling Outage O
Equipment items (DLC TAB f/FRC f) 23/55, 31/77, 36/26, f
36/27, 36/28, 37/24, 37/25, 38/58 and 46/61 have been replaced by qualified equipment during the DL h efueling Outage of 1982 and qualification documentation for the replacement equipment is located in the Duquesne Light Company EQ File.
B.
Equipment Scheduled for Replacement Equipment items (DLC Tabf/FRC#)
14/38, 15/36, 16/48, n
16/49, 17/41, 19/47, 19/91, 21/40, 25/2, 25/90, 32/74, 40/39, 40/43, 41/37, 41/42, 42/44 are scheduled for replacement.
Westinghouse Corporation has been issued a purchase order #CC520 on Dec. 19, 1980, for these equipment items.
Some of the items have now been received at the site.
Qualification documents are currently being reviewed and installation will then be completed at the next available outage as soon as the qualification of the if equipment has been established.
3
^\\
C.
Cables O
The cables used at the Beaver Valley Power Station Unit 1, which are located both inside and outside containment, are Kerite, Cerro (Rockbestos), Okonite, and Continental.
All cables are currently qualified for harsh environment applications except the continental and vulkene Model 57275.
Continental cables are used inside the Viking penetrations and Duquesne Light Company plans to conduct a ratesting the Continental cable to alleviate the chemical program on spray and radiation concerns.
Some of the G.E.
Vulkene SIS wires were replaced during.
previous outages and any remaining wire that is mainly located inside Mccs and in locally mounted junction boxes for air operated valves, will be replaced within the time frame allotted by the NRC Rulemaking.
D.
Conduit Seals
.'O The initial method, contemplated by DLC used to seal the
)
limit switches, was shown on sheet 4-11 & 12 of the 79-OlB Oct. 15, 1981 Submittal.
However, test results of the Chico ceramic sealing compound used by this method indicated that the seal did.not prevent moisture leakage through the stranded conductors.
As a result, the sealing method could 1
not satisfy the requirements.
Duquesne Light Company is presently investigating Conax, in addition to several other sealing methods including RayChem, Bisco, and Dow Corning's RTV compound.
Conduit seals are used only at the equipment feed-through connections and are not an integral portion of the equipment.
The connected equipment items are qualified, i
- however, their overall qualification depends on the l
qualification of the external seals.
+
4
E.
Limitorque Motor Operators O
The most significant problem with the Limitorque Motor Operators is the identification of specific materials and motor brake design data so that the aging evaluation and qualified life / replacement cycle can be determined.
.i Duquesne Light Company has evaluated the qualified life of the identifiable materials on certain valve operators and all indicators point to a greater than 40 year life span, provided that periodic lubrication replacement occurs.
Action is being taken to identify all degradable materials through the manufacturer to remove the NRC quote.d deficiencies.
In response to IE circular 79-04, a comprehensive walkdown of all Limitorque Motor Operators was conducted in 19_79 to identify all the Limitorque's in the plant.
The report was submitted to the NRC on March 16, 1979.
Excerpts from various test reports. indicate that all Limitorque Operators belong to the generic family with the same materials of construction but of different sizes.
For example, Test Report B0037 Section 2.0.1 identifies that the I
entire line of valve actuators including the electric motor i
types SMB/SB/SBD/SMC/HBC, is a generic family.
All are f
constructed of similar materials with physical size varying as a function of ratings.
Duquesne Light. Company is in the process of obtaining any additional information from the manufacturer to establish the applicability of specific test reports to each motor operator that has a traceability question.
L 5
1
TABLE I
SUMMARY
OF EQUIPMENT ITEMS IN EACH CATEGORY O
TAB NUMBERS LISTED ARE DLC/NRC NUMBER OF EQUIP. ITEMS DLC NRC DIFFER-REVIEW REVIEW ENCE I.a EQUIPMENT QUALIFIED 14 5
+9 2/69 22/52 23/55 27/50 29/81 31/77 33/73 46/62 46/61 1/70*
3/68*
4/71*
S/76*
30/78*
I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION 35 40
-5 5/72 6/75 7/79 10/29 10/30 10/31 10/32 10/33. 10/34 10/35 11/59 13/57 14/38 15/36 17/41 18/83 19/47 19/91 21/40 22/53 25/90 27/51 32/74 36/26 36/27 36/28 37/24 37/25 38/58 39/84 40/39 40/43 41/37 41/42 42/44 II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED 9
30
-21 16/49 20/46 25/2 25/3 25/4 25/5 45/10 45/12 45/15
~II.b EQUIPMENT NOT QUALIFIED 0
0 0
~II.c EQUIPMENT SATISFIES ALL REQUIREMENTS 14 8
+6 EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED 8/80 26/56 35/65 35/66 35/67 44/22 44/23 44/88 45/11 45/13 45/14 45/89 f
47/63 48/64 l
III.a EQUIPMENT EXEMPT FROM QUALIFICATIONS 10 3
+7 28/6 28/7 28/8 28/9 28/45 28/54 28/60 45/16* 43/17* 43/82*
III.b EQUIPMENT NOT IN THE SCOPE OF REVIEW 8
5
+3 24/1 43/20 43/18* 43/19* 43/21* 43/85*
l.
43/86 43/87*
IV.
DOCUMENTATION NOT MADE AVAILABLE O
O-0 90 91
-1 TOTAL
=
O
- Equipment items not reviewed by DLC and assigned the same qualification category as NRC Review.
Equipment item 16/48 has been combined with Equipment item 16/49.
6 L
III EXECUTIVE
SUMMARY
O 79-FRC EQUIPMENT QUAL.
CATEGORY PLANNED ACTION 01B TABt MANUFACTURER DLC NRC/FRC TABf I.a None (qual by NRC Review) 1 70 Kerite 2
69 Cerro I.a II.a None (qual by DLC Review) '
I.a None (qual by NRC Review) 3 68 Okonite I.a None (qual by NRC Review) 4 71 Okonite 5
72 Continental I.b I.b Retest for chemical spray and radiation 6
75 Viking I.b II.a Retest penetration for higher radiation dosage 7
79 Buchanan I.b I.b Retest 8
80 Penn Union II.c II.a Conduct aging. analysis and determine replacement cycle I.a None (qual by.NRC Review) 9 76 Rockbestos
')
10 29 ASCO I.b I.b Install qualified seal at NP8320A184E conduit interface 10 30 ASCO I.b I.b Install qualified seal at NP8320A188E conduit interface 3
10 31 ASCO I.b I.b Install qualified seal at NP8320A186E conduit interface 10 32 ASCO I.b I.b Install qualified seal at NP8320A186E conduit interface 10 33 ASCO I.b I.b Install qualified seal at NP8320A186E conduit interface 10 34 ASCO I.b I.b Install qualified seal at NP831654E conduit interface 10 35 ASCO I.b I.b Install qualified seal at NP8316A74E conduit interface O
1 i
III EXECUTIVE
SUMMARY
O 79-FRC EQUIPMENT
- QUAL, CATEGORY PLANNED ACTION 01B TABf MANUFACTURER DLC NRC/FRC TABf 11 59.
NAMCO I.b I.b Install qualified conduit seals at interface 13 57 NAMCO I.b I.b Install qualified conduit seals at interface 14 38 Fischer &
I.b I.b Replace with qualified Barton Lot 5 transmitters Porter 15 36 Barton I.b II.a Replace with qualified Barton Lot 5 transmitter I.b None (exempt from 16 48 Barton 386 qualification) 16 49
'Barton II.a II.a Investigate test program 764 LOT 2 anomaly.
Obtain procedures for soldering 41 Gems I.b I.b Replace with qualified O 17 transmitter
)
18 83 Mason-Neilan I.b I.b Rep 1. ace with qualified Barton Lot 5 transmitter 19 47 Fischer &
I.b I.b Replace with qualified Barton Lot 5 transmitter Porter I
19 91 Fischer &
I.b I.b Replace with qualified Barton Lot 5 transmitter Porter 20 46 Barton II.a II.a Perform aging analysis.
Obtain soldering procedures for connectors 21 40 Barton I.b I.b Replace with qualified Barton Lot 5 transmitter 386 22 53 Sostman I.b II.a Review qualification of Wide Range new RTDs of RDF Corp.
22 52 Sostman I.a II.a None (units are Narrow Range considered qualified) 23 55 Trinity I.a I.b Replaced with Conax during 2RFO r
24 1
Limitorque III.b II.a None (not in the scope of SMB-0 review) 2 i
III EXECUTIVE
SUMMARY
O 79-FRC EQUIPMENT QUAL.
CATEGORY PLANNED ACTION OlB TABS MANUFACTURER DLC NRC/FRC TABS 25 2
Limitorque II.a II.a Perform aging analysis, j
SMB-00 replace (MOV-CH-310) with qualified operator 25 3
Limitorque II.a II.a Identify materials of SMB-00 construction, establish similarity and perform aging analysis 25 4
Limitorque II.a II.a Identify materials of SMB-00 construction, establish similarity and perform aging analysis 25 5
Limitorque II.a II.a Identify materials of SMB-00 construction, establish similarity and perform 1
aging analysis 90 Limitorque I.b I.b Review qualification O 25 SMB-00 documents and replace
)
26 56 G.E.
II.c II.a Perform aging analysis on the lead splice, lead cable insulation, bearings, and lubricant 27 50 Endevco I.a I.b The acclerometer is
)
qualified 27 51 Unholtz I.b I.b Retest the accoustical i
Dickie monitoring system or procure a different system
(
28 6
Limitorque III.a II.a None (exempt from SMB-00 qualification) t l
L 28 7
Limitorque III.a II.a None (exempt from SMB-00 qualification) 28 8
Limitorque III a II.a None (exempt from SMB-2 qualification) 28 9
Limitorque III.a II.a None (exempt from SMB-1 qualification) c I
t
{a 1
3 i
bw
III EXECUTIVE
SUMMARY
O-79-
.FRC EQUIPMENT QUAL.
CATEGORY PLANNED ACTION 01B TAB 9 MANUFACTURER DLC NRC/FRC TAB 6 28 45.
Fischer &
III.a I.b None (exempt from Porter qualification) 50EP1041
~28-54 Control Prod..
III.a II.a None (exempt from qualification) 28-60 Westinghouse III.a II.a None (exempt from S070F67868 qualification 29 81-Marathon I.a I.b None (qual by DLC Review)
I.a None (qual by NRC Review)
[
30 78 Okonite 31 77 Kerite I.a I.b Replaced during 2nd RFO with qualified item 32 74
.Vulkene I.b I.b Replace during 3rd RFO 73 Vulkene I.a II.a None (qual by DLC Review)
( )
33 35 65 Allis Chalmer II.c II.a Perform aging analysis of control transformer 3-35.
66 Allis Chalmer II.c II.a Perform aging analysis of control transformer
?
35.
.67 Allis Chalmer II.c II.al Perform aging analysis of control transformer 36 26 ASCO I.b I.b Replaced during 2nd RFO HP8320A26 with qualified equipment.
Install qualified seal at conduit interface 36 27 ASCO I.b I.b Replaced during 2nd RFO HP8320A26 with qualified equipment.
Install qualified seal at conduit interface 36 28 ASCO I.b I.b Replaced during 2nd RFO HP8320A26 with qualified equipment.
Install qualified seal at conduit interface
( )
37 24 ASCO I.b I.b Replaced during 2nd RFO LB831654 with qualified equipment.
Install qualified seal at g
conduit interface 4
s'
i III EXECUTIVE
SUMMARY
79-FRC EQUIPMENT QUAL.
CATEGORY PLANNED ACTION 01B TABf MANUFACTURER DLC NRC/FRC TABf 37 25 ASCO I.b I.b Replaced during 2nd RFO LB831654 with qualified equipment.
Install qualified seal at conduit interface 38 58 NAMCO I.b I.b Limit switches replaced D2400X during 2RFO with qualified equipment. Install qualified seals at conduit interface 39 84 NAMCO I.b I.b Install qualified seals EA740 at conduit interface 40 39 Fischer &
I.b I.b Replace with qualified Barton Lot 5 transmitter Porter 40 43 Fischer &
I.b I.b Replace with qualified Barton Lot 5 transmitter Porter
[
41 37 Fischer &
I.b I.b Replace with qualified Barton Lot 5 transmitter Porter 41 42 Fischer &
I.b I.b Replace with qualified Barton Lot 5 transmitter Porter 42 44 Fischer &
I.b I.b Replace with qualified Barton Lot 5 transmitter Porter III.a None (exempt from qual.)
f.'
43 16 Limitorque f
43 17 Limitorque III.a None (exempt from qual.)
III.b None (not in scope of revie3 43 18 Limitorque III.b None (not in scope of revie:
43 19 Limitorque 43 20 Limitorque III.b II.c None (exempt from qual.)
SMB-00 l
III.b None (not in scope cf revies I
43 21 Limitorque III.a None (exempt from 43 82 Limitorque qualification)
( )
43 III.b None (not in scope of revie1 85 Limitorque 43 86 Limitorque III.b II.a None (same as equipment number 43/20) l l
43 87 Limitorque III b None (not in scope of l
review) 5
III EXECUTIVE
SUMMARY
j f~3 d
79-FRC EQUIPMENT QUAL.
CATEGORY PLANNED ACTION 01B TABf MANUFACTURER DLC NRC/FRC TABl.
Perform aging analysis 44 22 Limitorque II.c II.c (SMB-2T)
Perform aging analysis 44 23 Limitorque
-II.c II.c (SMB-00) 44 88 Limitorque II.c II.c Perform aging analysis SME-00 45 10 Limitorque II.a II.a Obtain traceability
~
documents and motor brake SMB-00 details Perform aging analysis 45 11 Limitorque II.c II.c and identify motor brake SMB-00 details
/~S 45 12 Limitorque II.a II.a Obtain traceability documents and motor ~ brake
\\
SMB-00 details b
45 13 Limitorque II.c II.c Perform aging analysis and identify motor brake SMB-00 details Perform aging analysis 45 14 Limitorque II.c II.c and identify motor brake SMB-00 details 45 15 Limitorque II.a II.a Obtain traceability documents and motor brake SMB-00 details 45 89 Limitorque II.c II.c Perform aging analysis and identify motor brake SMB-00 details 46 61 Louis Allis I.a I.b None (motors were replaced i
by qualified equipment during 2nd RFO) 46 62 Louis Allis I.a II.a None (qualified by DLC Review) 47 63 Westinghouse II.c II.a Analyze motor constituent parts for thermal, radiation, and wear aging 48 64 Westinghouse II.c II.a Analyze constituent parts for thermal, radiation, and wear aging M
DLC TAB f 1 FRC TAB i 70 O
DLC RESPONSE 10 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-015 TAB NUMBER:
1 FRC NUMBER (S):
70 I
EQUIP DESCRIPTION:
Electrical Cable EQUIP HARK NO (S): N/A MANUFACTURER:
Kerite HODEL NUMBER (S):
5000V Kerite Insulation 6
O
~
NO ADDITIONAL REVIEW WAS CONDUCTED i
BECAUSE THE EQUIPMENT IS CONSIDERED QUALIFIED i
~
O w+e-p-m
.y p
-.- -. - - = - -
-e, m-7.--
--w y.--.,-
.-,myy-a..-,,
.y-----
--w-,
..-w,,.,e.-w or,-i-
-,w w
w--
-4_
2m--
a,-.
5
.u_..4...A_<
.-=s---m-m - - _
m u--+i 2.0 NRC/FRC QUALIFICATION CATECORY O
FRc Lc 1.s EQUIPMENT QUALIFIED K
I.h EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT, QUALIFICATION NOT ESTABLISNED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT 4
QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW
)
IV.
DOCUMENTATION NOT MADE AVAILABLE O
3 I
D F
I I
5 O
s
'l
-,-,,,=-.,~---w 1
.w---
- - - -~-,,
2--
+---
)
f DLC TAB f 2 FRC TAB f '69
~
O DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 2 FRC NUMBER (S)?
69 EQUIP DESCRIFTION: Electric Cable EQUIP MARK NO (S): NFB-65 MANUFACTURER:
Cerro Wire and Cable Company (The Rockbestos Company)
MODEL NUMBER (S):
Silicone Rubber Insulation 2.0 BRIEF OVERVIEW OF STATUS As stated in the DLC 30-day response a letter from the manufacturer states the insulation of the cable shipped was silicone rubber and that the silicone rubber insulation was manufactured by either Dow-Corning or General Electric, which are i
both qualified for application in this plant.
Cerro Wire and Cable Co. Test Reports FC-2750 and FC-2875 have both of these compounds specifically stated.
Therefore, since the manufacturer provided distinct r.aterial information on the insulation compound of the cable shipped, which matches the test reports' insulation compound, the similarity has been established.
t 3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL P
QUALIFICATIONS STATUS:
Qualified.
i B.
EDS REVIEW QUALIFICATIONS STATUS:
Not reviewed.
P C.
FRC/NRC QUALIFICATIONS STATUS:
(II.a) Equipment Qualification not established.
DEFICIENCIES / CONCERNS:
Similarity between installed cables and test specimens not established.
Documented evidence of qualification inadequate.
D.
DLC REVIEW l
QUALIFICATIONS STATUS:
(I.a) Equipment qualified.
O e
4.0 NRC/FRC QUALIFICATION CATECORY FRC DLC X
I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISNED X
II.b EQUIPMENT NOT QUALIFIED J
II.c EQUIPNENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
The difference in qualification was due to being able to establish similarity O
between the cable installed and the cables tested.
)
5.0 REVIEW OF NRC/FRC DEFICIENCIES
)
A.
DEFICIENCY CONCERN: Documentation of Qualification Inadequate.
g DISCUSSION / PROPOSED ACTION:
The establishment of similarity between cables installed and cables tested removed this deficiency.
NRC/FRC has Cerro Wire and Cable Co. Test Reports FC-2750 and FC-2857 which resolves this matter.
f y
O a
}
B.
DEFICIENCY CONCERN: Similarity between Installed Cable and Test Specimen not Established.
DISCUSSION / PROPOSED ACTION:
A letter from the manufacturer dated 1-14-83, has given the description of the cable shipped as a 1/C 500 MCM, Silicone Rubber Asbestos Braid, Silicone Finish.
The letter also states that both GE and Dow Corning manufacture a methyl-phenyl-vinyl compound used for cable insulation commonly referred to as silicone rubber.
Both compounds are used interchangeably by the Cerro Wire and Cable Co.
Both of these compounds were covered by Cerro Wire and Cable Co.
test reports FC-2750 and FC-2857 and have a determined qualified life.
Therefore, the identification of the cable installed insulation can be traced to test reports.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-OlB DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981)
- O
)
7.0 OTHER REFERENCE DLC DOCUMENTS 1.
MANUFACTURER TRACEABILITY DOCUMENTS (Reference Letter from P. Moore, The :Rockbestos Company to J.E.
Livingston, Schneider Consulting Engineers, dated January 14.,
1983.
N This letter is in the DLC EQ File - IV.B.1/2).
2.
SUPPLEMENTARY ANALYSIS (Extended Life Analysis in Duquesne Light Company EQ File - IV.B.1/2).
3.
AGING EVALUATION (Thermal Aging Analysis in Duquesne Light Company EQ File - IV.B.1/2).
f O
8 W
i DLC TAB f 3, FRC TAB f 68 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 BQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 3 FRC NUMBER (S):
68 EQUIP DESCRIPTION: Electrical Cable EQUIP MARK NO (S): N/A MANUFACTURER:
Okonite MODEL NUMBER (S):
600V Okonite Insulation O
)
F NO ADDITIONAL REVIEW WAS CONDUCTED i
BECAUSE EQUIPMENT IS CONSIDERED QUALIFIED r
O
2.0 NRC/FRC QUALIFICATION CATECORY FRC DLC I.a EQUIPMENT QUALIFIED X
I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE O
r h
l l
O 1.
T wD g
DLC TAB i 4 FRC TAB i H DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 4 FRC NUMBER (S):
71 EQUIP DESCRIPTION: Electrical Cable EQUIP MARK NO (S): N/A MANUFACTURER:
Okonite MODEL NUMBER (S):
Okonite Insulation O
3 NO ADDITIONAL REVIEW WAS CONDUCTED 1
BECAUSE o
EQUIPMENT IS CONSIDERED QUALIFIED i
O i
m 2.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC X
I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED l
III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW 1
IV.
DOCUMENTATION NOT MADE AVAILABLE j
i lO-i i
I l O P
DLC TAB i 5 FRC TAB f 72 m
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 5 FRC NUMBER (S):
72 EQUIP DESCRIPTION:
Instrument Cable EQUIP MARK NO (S): N/A MANUFACTURER:
Continental Wire & Cable Corporation MODEL NUMBER (S):
Silicone Rubber Insulation 2.0,BRIEF OVERVIEW OF STATUS j
The available test data is insufficient to demonstrate complete qualification of
[
this cable.
A re-testing program enveloping the required parameters is being developed per specification BVS-685.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL
)
QUALIFICATIONS STATUS:
Not Qualified DEFICIENCIES / CONCERNS:
1.
The cable was tested to acidic rather than caustic pH level.
2.
Radiation qualification does not envelope radiation environnese inside
[
the crane wall.
p, B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Qualified DEFICIENCIES / CONCERNS:
1.
Specified operating time not enveloped by test.
2.
Beta and Camma Radiation.
3.
Chemical Spray.
4.
Thermal Aging.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
1.
Radiation.
2.
Qualification Tim'e.
p 3.
Chemical Spray.
4.
Aging Degradation Evaluation b
5.
Qualified Life and Replacement Schedule.
l
D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
1.
Radiation.
2.
Qualification Time.
3.
Chemical Spray.
4.0 NRC/FRC QUALIFICATION CATECORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED 8
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE
}
5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Criteria regarding radiation not satisfactory.
DISCUSSION / PROPOSED ACTION:
The cab e is required to withstand 1x 10 Rad dosage and was tested to 1 x 10 R:"N The re-testing program will ine (p. mte the required dosage levet i
B.
DEFICIENCY CONCERN: Qualification time not adequate.
DISCUSSION / PROPOSED ACTION:
Re-testing program is being initiated to test the cable for the proper time duration.
i l
. ~ -. - -,.,-
a
C.
DEFICIENCY CONCERN: Criteria regarding chemical spray not satisfactory.
DISCUSSION / PROPOSED ACTION:
An independent review of important properties of silicone rubber. presented in
" Chemical Engineer's Handbook" reveals that it has fair to good acid and alkali resistance.
The re-testing program will take this into consideration.
D.
DEFICIENCY CONCERN: Aging degradation evaluation.
DISCUSSION / PROPOSED ACTION:
A thermal aging analysis for the insulation material shows greater than 50 years qualified life.
The radiation aging phenomenon will be taken into account during testing.
E.
DEFICIENCY CONCERN: Qualified life and replacement schedule.
DISCUSSION / PROPOSED ACTION:
Based-on the thermal aging analysis, the cables have a qualified life of greater than 50 years and replacement is not I
anticipated.
O 6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) i 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2 t
7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINJED OPERATION - (Reference 79-OlB, October 15, 1981) 2.
AGING EVALUATION (Reference Thermal-Aging Analysis in DLC EQ file -
IV.B.1/5) 3.
SPECIFICATION FOR EQ TESTING - SPEC BVS-685 I
8.0 DLC ACTION PLAN Because DLC believes this cable is qualifiable, it plans to conduct a re-testing program to - alleviate chemical spray and radiation concerns as soon as a test plan is developed and a testing laboratory selected.
The testing of the equipment is expected to be underway by 1984, t
i
=
DLC TAB # 6 FRC TAB f 75
(
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION $UMMARY 79-01B TAB NUMBER: 6 FRC NUMBER (S):
75 EQUIP DESCRIPTION: Electrical Penetration 1
EQUIP MARK NO (S): N/A MANUFACTURER:
Viking Industries MODEL NUMBER (S):
Type I, II, III, IV, V. VIII, and IX 2.0 BRIEF OVERVIEW OF STATUS f
Although the penetrations were previously tested to lower radiation dosage level, more recently conducted supplemental analysis related to radiation threshold values for various materials used in these penetrations has revealed that they are qualifiable.
It is currently anticipated that retesting of these penetrations will be underway by 1984.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL i
QUALIFICATIONS STATUS:
Qualified.
t DEFICIENCIES / CONCERNS:
Aging analysis had not been conducted yet to determine qualified life.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Reviewed.
C.
FRC/NRC QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established.
DEFICIENCIES / CONCERNS:
1.
Aging degradation not evaluated adequately.
2.
Qualified life and replacement schedule not established.
3.
Criteria regarding radiation not satisfied.
O O
y-y-,.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Radiation qualification was not established in previous testing, however, a radiation analysis indicates materials will not seriously degrade from DBE radiation exposure.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED X
II.b EQUIPMENT NOT QUALIFIED
-II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EKEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE
\\
l EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
DLC has proceeded with the development of a test plan to re-test the penetration sample which had been tested previously. This test is expected to provide full qualification status.
5.0 REVIEW OF NRC/FRC DEFICIENCIES l
A.
DEFICIENCY CONCERN: Aging Degradation Not Evaluated Adequately.
l l
DISCUSSION / PROPOSED ACTION:
Thermal aging analysis on degradable materials identified to date. indicates l
that the equipment has a qualified life l
of greater than 50 years prior to DBE.
The re-test is expected to demonstrate l
that radiation aging effects will not l
limit the units qualified life to less than 40 years.
I
B.
DEFICIENCY CONCERN: Qualified Life and Replacement Schedule Not Established.
DISCUSSION / PROPOSED ACTION:
Based on the thermal aging analysis of the degradable parts identified to date, it has been determined that the life of penetrations exceed the plant life (40 years) and replacement is not currently expected for this equipment or its constituent parts.
If the radiation aging during the re-test results in a shorter qualified life, the replacement schedule will be re-evaluated.
C.
DEFICIENCY CONCERN: Criteria Regarding Radiation Not Established.
DISCUSSION / PROPOSED ACTION:
The penetration assemblies were subjectedto40yearsaccumulateggamma radiation exposure of 1.11 x 10 Rads.
An additional analysis has enabled DLC extynd the qualification level to to 1x 10 Rads.
However, re-testing will be conducted to envelope the required plant parameters.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981)
)
i 7.0 OTHER REFERENCE DLC DOCUMENTS
[
1.
MANUFACTURER TRACEABILITY DOCUMENTS (Reference DLC EQ File IV.B.1/6) 2.
SUPPLEMENTAL ANALYSIS (Reference DLC EQ File IV.B.1/6) 3.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 30-Day 1983 Response) 4.
AGING EVALUATION (Reference DLC EQ File IV.B.1/6) 5.
COMMUNICATION WITH A/E ON RADIATION (Reference DLC EQ File IV.B.1/6) 8.0 DLC ACTION PLAN re-test of the Viking Electrical penetration will be conducted by an OAindependent testing laboratory to demonstrate the penetration's ability to withstand higher radiation levels.
The testing is expected to be underway by 1984.
_ _ _J
}
DLC TAB # 7 FRC TAB f 79 O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
7 FRC NUMBER (S):
79 EQUIP DESCRIPTION: Terminal Blocks (for Control and Instrumentation)
MANUFACTURER:
Buchanan MODEL NUMBER (S):
0511 and 0211 2.0 BRIEF OVERVIEW OF STATUS Viking Test Report 5450-4643 has qualified the Buchanan 0511 terminal blocks only.
DLC will test these terminal blocks to demonstrate qualification of the Buchanan 0211, 0511 terminal blocks.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
Radiation / thermal aging.
B.
EDS REVIEW i
QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
Radiation / thermal aging.
C.
FRC/NRC
' QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Similarity between test and installed equipment, aging evaluation inadequate, qualified life or replacement schedule not established.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.b)- Equipment Qualification Pending Modification.
O Thermal aging, similarity between equipment DEFICIENCIES / CONCERNS:
tested and installed equipment.
1
4.0 NRC/FRC QUALIFICATION CATECORY FRC DLC t
I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Similarity between tested and installed equipment.
DISCUSSION / PROPOSED ACTION:
DLC foreign
_ int record 8700-1.35-156A lists 0511 terminal blocks as being installed in BVPS #1, which establishes traceability between the installed and tested terminal blocks. The results are documented in Viking Test Report
- 5450-4643 for the 0511 blocks. Further tests are being conducted by DLCO en the Viking penetrations which will demonstrate qualification of the 0211 and 0511 blocks.
Franklin Research Center had successfully tested similar, but not identical, terminal blocks in a different qualification test, NQ0511 and NQ0211.
Those terminal blocks were designed specifically for containment use.
B.
DEFICIENCY CONCERN: Aging.
DISCUSSION / PROPOSED ACTION:
Further tests to establish aging qualification.
O a
C.
DEFICIENCY CONCERN: Qualified Life or Replacement Cycle.
DISCUSSION / PROPOSED ACTION:
Upon completion of the scheduled
- testing, the replacement cycle if required for these terminal blocks will be established.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15,-
1981 Submittal) 2.
FRC FINAL REPORT F-C343 (DLC EQ File VB1.1.6*)
8.0 DLC ACTION PLAN Results of the DLC terminal block tesc should establish qualification of Buchanan 0511 and 0211 terminal blocks.
This test will establish traceability between the test specimens and the installed items and address any aging concerns.
- See Section 5.0(A)
DLC TAB # 8 FRC TAB # 80 O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 8 FRC NUMBER (S):
80 EQUIP DESCRIPTION: Terminal Block EQUIP MARK NO (S): Not Applicable MANUFACTURER:
Teledyne-Penn Union MODEL NUMBER (S):
Series 1000 2.0 BRIEF OVERVIEW OF STATUS Penn Union Series 1000 Terminal Blocks are qualified for inside containment use.
The noted deficiencies in the Franklin Technical Evaluation Report have been adequately addressed.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified, i
i B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Reviewed.
C.
FRC/NRC QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established.
l DEFICIENCIES / CONCERNS:
Similarity between tested and installed equipment, steam exposure inadequate.
l D.
DLC REVIEW QUALIFICATIONS STATUS:
(II.c) Equipment satifies all the requirements except qualified life or j
replacement achedule justified.
l
/
l l
l
I d
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED 1.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED I
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED X
III.s EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE i
EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
The deficiencies noted by the FRC/NRC SER have been adequately addressed and the O
terminal blocks _ are qualified with the exception of qualified life or l
replacement schedule evaluation. The test report, currently in the DLC EQ File.
}
as well as the physical plant walkdown has eliminated the traceability concern.
5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Similarity - between tested equipment and
)
installed equipment.
I DISCUSSION / PROPOSED ACTION:
A review of the Viking Penetration i
drawings anc a walkdown report of the plant indicated that no terminal blocks have been found in the plant that are longer than the 8 point terminal blocks.
The DLC Test Report dated 3-25-80 tested 4 point and 8 point Penn Union Terminal Blocks and the DLCO test report is considered applicable to the terminal blocks installed.
The plant walkdown indicated that-the common approach inside containment was to run wire j
straight through from the penetration cabinet to the equipment without the use of_any intermediate terminal blocks.
s
--~
,,m,_,_._._,-,
h B.
DEFICIENCY CONCERN: Steam Exposure Inadequate.
DISCUSSION / PROPOSED ACTION:
DLCO Test Report dated 3-25-80 states that a steam test was performed for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> and no distortions or loss of insulation resistance were observed.
Additional analysis that was conducted demonstrates that the test profile is more severe than the plant profile.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal October 15, 1981) 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
SUPPORT DOCUMENTS (Reference Viking Penetration Equipment. Drawings and Walkdown Report).
2.
JUSTIFICATION FOR CONTINUED OPERATION - (30-Day 1983 Response).
3.
DLC TEST REPORT (Reference DLC EQ File VBl.16.1) 4.
SUPPLEMENTAL ANALYSIS (Reference DLC EQ File IV.B.1/8) 8.0 DLC ACTION PLAN Aging analysis is being conducted on these terminal blo'ks and the replacement a*
schedule will be established.
O c
d s
DLC TAB # 9 FRC TAB i 76 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 9 FRC NUMBER (S):
76 EQUIP DESCRIPTION: Electrical Cable EQUIP MARK NO (S): N/A MANUFACTURER:
Rockbestos MODEL NUMBER (S):
Firewall SIS O
i NO ADDITIONAL REVIEW WAS CONDUCTED i
BECAUSE L
EQUIPMENT IS CONSIDERED QUALIFIED l
O
2.0 NRC/FRC QUALIFICATION CATECORY FRC DLC K
I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE O
3
/
O O
^-
DLC TAB f 10 FRC TAB f 29,30,31,32,
()
33,34,35 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMEST 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
10 FRC NUMBER (S):
29,30,31,32,33,34.35 EQUIP DESCRIPTION: Solenoid Valves EQUIP MARK NO (S): See Attached Table 10-1 MANUFACTURER:
ASCO MODEL NUMBER (S):
See Attached Table 10-1 2.0 BRIEF OVERVIEW OF STATUS Duquesne Light Company is continuing in its efforts to find a qualified conduit / solenoid valve interface seal and will install the qualified seal when available.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
Aging, qualification method, qualification i
information being developed.
A qualified conduit seal is needed.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification DEFICIENCIES / CONCERNS:
Effect of chemical spray (conduit seal).
D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification g
DEFICIENCIES / CONCERNS:
The solenoid valve itself is qualified.
The effects of chemical spray on the conduit seal is currently being addressed.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Chemical Spray.
DISCUSSION / PROPOSED ACTION:
The migration of steam into the solenoid d
housing will be eliminated by the installations of a qualified conduit seal system.
)
B.
DEFICIENCY CONCERN: Electrical Interface (Conduit Seal).
DISCUSSION / PROPOSED ACTION:
Duquesne Light Company is investigating three different conduit seal systems.
When a qualified seal system is found, it will be installed at the first opportunity.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981) o
7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981, Submittal) i 8.0 DLC ACTION PLAN All attempts are being made by Duquesne Light Company to qualify and install the conduit seals within the time frame allotted by the recent NRC Rulemaking.
e f
' O l
l i
O
TABLE 10-1 1
ASCO ITEM LOCATION FRC/NRC DLCO MODEL NUMBER' MARK NUMBER ITEM NO.
STATUS ITEM NO.
STATUS
~
1 i
1 i
NP-8320A184E SOV-LM-101A CONTAINMENT 29' I.b 10 I.b i
SOV-LM-101B 0UTSIDE CRANEWALL l
NP-8320A188E SOV-SS-000A CONTAINMENT 30 1.b 10 I.b i
NP-8320A186E SOV-CC-103Al CONTAINMENT 31 I.b 10 I.b i
SOV-CC-103B1 OUTSIDE CRANEWALL j
SOV-CC-103C1 i
SOV-CC-105D1 SOV-CC-105El l
SOV-CC-107D1 SOV-CC-107El l
SOV-CC-110D SOV-CC-110E3 I
SOV-CC-111A2 i
SOV-CC-111D1 NP-8320A186E SOV-CV-102-1 CONTAINMENT 32 I.b 10 I.b i
SOV-DA-100A OUTSIDE CRANEWALL i
SOV-DG-108B SOV-DG-109A2 3
NP-8320A186E SOV-SI-101-2 CONTAINMENT 33 I,b 10 1.b I
NP-831654E SOV-CH-200A1 CONTAINMENT 34 I.b 10 I.b I
SOV-CH-200B1 SOV-CH-200C1 SOV-RC-456-1 i
SOV-RC-456-2 i
i NP-8316A74E SOV-RC-455C1 CONTAINMENT 35 I.b 10 I.b SOV-RC-455C2 SOV-RC-455D1 7
1 SOV-RC-455D2 i
ABBREVIATIONS:
I,b = Equipment Qualification Pending Modification s
DLC TAB # 11 FRC TAB f 59
~~
O DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
11 FRC NUMBER (S):
59 EQUIP DESCRIPTION: Limit Switch EQUIP MARK NO (S): LMS-CC-105D1; LMS-CC-111D1; LMS-CH-200A B.C; LMS-RC-455C.D; LMS-RC-456; LMS-SI-101-2 MANUFACTURER:
NAMCO MODEL NUMBER (S):
EA18011302 1
2.0 BRIEF OVERVIEW OF STATUS The limit switch itself is qualified; however, its associated conduit seal was tested during the second refueling outage and it failed. Duquesne Light Company l
is continuing in its effort to find a qualfied seal and to install it at the first opportunity.
It is noted that NRC/FRC has exempted LMS-SI-865A,B.C from qualification review because this equipment does not provide a safety function or mitigate the consequences of a design basis accident.
I i
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL i
QUALIFICATIONS STATUS:
Qualified 4 years.
l l
DEFICIENCIES / CONCERNS:
Electrical interface (conduit seal).
I B.
EDS REVIEW QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
Electrical interface (conduit seal),
traceability.
I C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Inadequate steam exposure.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(I,b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Electrical interface (conduit seal).
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED X
X I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED i
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT. EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE
)
i 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Inadequate Steam Exposure 3
DISCUSSION / PROPOSED ACTION:
Water migrating into housing from steam exposure will be eliminated by conduit seal. DLC will install a qualified seal when a qualified seal becomes available.
i l
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) i 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 7.0 OTHER REFERENCE DLC DOCUMENTS 4
l 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981. Submittal)
~..
l 8.0 DLC ACTION PLAN All attempts are being made by Duquesne Light Company to qualify and
' install the conduit seals.within the time frame allotted by the recent NRC Rulemaking.
1 i
1!O 4
l l
f O
,,.,_,.g,.
.,_.n._._
-n n
e-
O DLC TAB # 12 l
EQUIPMENT NO LONGER ASSIGNED O
TO THIS TAB NUMBER S
i O
l DLC TAB # 13 f
FRC TAB # y l
i d
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT i
1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
13 t
FRC NUMBER (S):
57 EQUIP DESCRIPTION: Litait Switches EQUIP MARK NO (S): LMS-DA-100A LMS-CC-110D LMS-DG-108A LMS-CC-111A2 LMS-DG-109A2 LMS-CV-102-1 LMS-CC-103A1,Bl C1 LMS-CC-105El LMS-CC-107D1.El LMS-CC-110E3 MANUFACTURER:
NAMCO MODEL NUMBER (S):
EA740-20100 and EA740-20000 2.0 BRIEF OVERVIEW OF STATUS The original NAMCO Limit Switches which were installed have a qualified life, however, qualification of an interface conduit seal has not at this time been demonstrated.
Duquesne Light Company is continuing in its efforts to find a O'
qualified seal and will install the qualified seal when available. LMS-CC-110E3 was included in Duquesne Light Co. review but -was not addressed by NRC/FRC review.
l i
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
Electrical interface (conduit seal).
B.
EDS REVIEW QUALIFICATIONS STATUS:
Acceptable.
DEFICIENCIES / CONCERNS:
Electrical interface (conduit seal) traceability.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Inadequate steam exposure.
4 D.
DLC REVIEW
()
QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES /CCNCERNS:
Electrical interface (conduit seal).
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I
I.a EQUIPMENT QUALIFIED 1
Ib EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED l'
EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT II.c QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION l
REVIEW l
~
IV.
DOCUMENTATION NOT.MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Inadequate Steam Exposure.
DISCUSSION / PROPOSED ACTION:
A qualified conduit seal will prevent steam from migrating into housing. DLCO to continue its efforts to find a qualified seal and install the qualified seal system when available.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 1 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B October 15.
1981, Submittal)
I S.0 DLC ACTION PLAN All attempts are being made by Duquesne Light Company to qualify and install the conduit seals within the time frame allotted by the recent NRC Rulemaking.
l O
l.,
k I
l-O m.,,
._m._
~
m-..
A DLC TAB # 14 FRC TAB i j DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT
- 1. 0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
14 FRC NUMBER (S):
38 EQUIP DESCRIPTION: Flow Transmitter EQUIP MARK NO (S):
FT-MS-474, 475, 484, 485, 494, 495 MANUFACTURER:
Fischer & Porter MODEL NUMBER (S):
10B2496PBBABDBNS 2.0 BRIEF OVERVIEW OF STATUS Although the Fischer & Porter Transmitters have a reasonable chance of being qualified for non LOCA, MSLB, and HELB affected areas, they have incurred failures during tests because of steam entry into their electronics. They are apparently able to operate ~ for a few minutes in a steam environment.
The previously committed date of June 1982 was unable to be realized, because qualification documentation for the replacement.Barton Transmitters had not been received or reviewed to assure qualification.
It is currently anticipated that
.%)
the replacement of the F & P Transmitters can be accomplished within the time frame allotted by the NRC Rulemaking.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Not Qualified; will be Replaced.
DEFICIENCIES / CONCERNS:
Qualification does not meet the one bour margin requirement of NUREG-0588.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Qualified; Replace Device.
DEFICIENCIES / CONCERNS:
The device is not qualified for the specified integrated radiation dose.
j C.
FRC/NRC QUALIFICATIONS STATUS:
(I b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Aging degradation evaluation and the j
O-qualified life / replacement cycle are not 4
addressed.
Steam exposure and radiation criteria is not adequate.
Test duration margin and the criteria regarding test failures is not satisfactory.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
The qualification level for radiation, qualification time, chemical spray as well as the DOR Guideline margins and aging evaluation requirements are not satisfactory.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC l
I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X j
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW f
IV.
DOCUMENTATION NOT MADE AVAILABLE i
5.0 INITIAL DLC REVIEW DOCUMENTS 9-1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) l 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 6.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15,
- ~
1981,' Submittal) i 7.0 DLC ACTION PLAN i
DLC is actively pursuing the appropriate qualification documentation for the
. replacement Barton Transmitters which have been received at the Beaver Valley Power Station, but not installed pending the receipt -of qualification T.
documentation from the supplier.
It is anticipated that they will be installed within the time frame allotted by the NRC Rulemaking.
., ~..
DLC TAB i 15 FRC TAB f LEI DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
15 FRC NUMBER (S):
36 EQUIP DESCRIPTION: Flow Transmitter EQUIP MARK NO (S):
FT-SI-961, 962, 963 MANUFACTURER:
ITT Barton MODEL NUMBER (S):
386 2.0 BRIEF OVERVIEW OF STATUS These instruments will be replaced with Barton transmitters pending receipt of adequate qualification documentation from the supplier.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL
.O QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
Chemical spray, submergence and post accident time requirements. The existing transmitters will be replaced with qualified transmitters.
B.
EDS REVIEW l
QUALIFICATIONS STATUS:
Not Qualified.
l l
DEFICIENCIES / CONCERNS:
Similarity between equipment installed and I
test specimen, aging analysis, inadequate test duration, chemical spray, submergence l
and qualified life.
C.
FRC/NRC QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established.
DEFICIENCIES / CONCERNS:
Similiarity between equipment installed and test specimen, aging analysis, inadequate test duration, chemical spray, submergence and instrument accuracy.
t 1
r._,
i l
D.
DLC REVIEW l S QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending
\\'/
Modification.
DEFICIENCIES / CONCERNS:
The transmitters will be installed as soon as qualification documentation has been received and qualification evaluated successfully.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
f II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED X
II.b EQUIPMENT NOT QUALIFIED i
II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION
()
III.b EQUIPMENT NOT IN THE' SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
Because qualification could not be established for the original plant flow transmitters, it was decided that replacement with qualified transmitters would be necessary, hence the difference in qualification categories.
5.0 REVIEW OF NRC/FRC DEFICIENCIES Several of the deficiencies pointed out by the NRC/FRC review had been recognized by DLC in its original 79-01B submittal to the NRC and it was for these reasons that DLC decided to initiate their replacement.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
LUMMARY SHEETS (Reference 79-01B DLC Submittal, October 15, 1981)
()
-2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) i i
. - = _ - - - =
9 7.0 OTHER REFERENCE DLC DOCUMENTS A -
1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B Submittal, October 15, 1981) 8.0 DLC ACTION PLAN i
1)
The equipment will be replaced with Barton Transmitters within the time frame allotted by the NRC Rulemaking.
2)
The new Barton Models are apparently not qualified for submergence.
As a result, the new transmitters are to be located at least two feet above their present level to avoid the submergence problem.
O 1
9 i
i e
O
DLC TAB # 16 FRC TAB f 3 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
16 FRC NUMBER (S):
48 EQUIP DESCRIPTION: Level Transmitters EQUIP MARK NO (S): LT-RC-459 MANUFACTURER:
ITT Barton MODEL NUMBER (S):
386 (Temporary Replacement) 2.0 BRIEF OVERVIEW OF STATUS The Barton Model 386 is the original transmitter installed.
This transmitter was replaced several years ago by the Barton 764. Lot 2 transmitter.
- However, the Model 386 was re-installed as a temporary replacement for the 764, Lot 2 Model which had developed a calibration problem and had been sent to the vendor for repair.
DLC received the 764, Lot 2 transmitter back from the vendor and has since installed it in the plant.
Therefore, Model. 764 Lot 2 is now associated with this mark number. (Refer to DLC Tab #16/FRC Tab #49) and the Model 386 is exempt from this qualification review.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL
)
QUALIFICATIONS STATUS:
Not Qualified.
i DEFICIENCIES / CONCERNS:
Chemical spray, aging, margins and replacement schedule.
B.
EDS REVIEW QUALI?ICATIONS STATUS:
Not Received.
DEFICIENCIES / CONCERNS:
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Traceability, aging degradation, qu.
(fied life not established; test duration inadequate, chemical spray and instrument accuracy.
10
I D.
DLC REVIN O
QUALIFICATIONS STATUS:
(N/A) Model 386. Equipment Exempt From Qualification DEFICIENCIES / CONCERN $t This transmitter has been replaced by the Model 764, Lot 2 and should be evaluated as a part of FRC Tab 49/79-01B Tab 16.
i 4.0 NRC/FRC QUALIFICATION CATEGORY RC DC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED f
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN TNE SCOPE OF TNE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE l
(
EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
Model 386 was installed temporary replacement to Barton Model 764. Lot 2, which developed a calibration problem, and was sent to the manufacturer for repairs.
This transmitter was repaired and returned to DLC. Transmitter (764, Lot 2) was re-installed after it had been repaired.
5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: All Deficiencies.
DISCUSSION / PROPOSED ACTION:
This transmitter is replaced by Model 764, Lot 2, and will be incorporated as a part of FRC Tab #49/79-01B Tab 16.
O b
6.0 INITIAL DLC R!IVIEW DOCUMENTS
)
O 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981)
- VOIDF.D 2.
SCEW SHEETS (Reference 79-015 DLC Submittal, Oct. 15, 1981) - VOIDED 7.0 OTHER RE7/ERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981. Submittal) i O
1 f
O
DLC TAB i 16 FRC TAB i y DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
16 FRC NUMBER (S):
49 EQUIP DESCRIPTION: Level Transmitter EQUIP MARK NO (S): LT-FW-474,475,476,484,485.486*,
494,495,496, LT-RC-460*, 461*
LT-RC-459**
MANUFACTURER:
ITT Barton MODEL NUMBER (S):
764 Lot 2 2.0 BRIEF OVERVIEW OF STATUS These transmitters located inside containment, require additional manufacturer's review of test anomalies and are expected to be qualified.
I Currently pending is the soldering of their pin connectors and conducting an aging evaluation.
The qualification program for these transmitters was
(
developed to address NUREG-0588 Cat II.
NUREG 0588 Cat II requires that the materials susceptible to degradation be established.
Evaluation of the qualified life of the equipment and its constituent parts and determination of the replacement schedule will be performed.
3.0 REV EWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
Thermal Aging, Chemical Spray.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
Inadequate Operating Time and Chemical Spray.
Omnitted in the FRC Technical Evaluation Report.
LT-RC-459 Mark Number from FRC Tab Number 48 has been added to this FRC Tab
- 49 because it has the same manufacturer, model, and location as the other level transmitters.
I lL
C.
FRC/NRC QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established DEFICIENCIES / CONCERNS:
Aging, qualified life and replacement schedule not established and test anomaly.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established.
DEFICIENCIES / CONCERNS:
Aging Qualified life or replacement schedule not established and calibration shift anomaly.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED X
X II.b EQUIPMENT NOT QUALIFIED
)
II.c EQUIPMENT SATISFIES ALL REQUIREMEhYS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHITULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATIFI III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Aging Degradation.
DISCUSSION / PROPOSED ACTION:
Aging was not-a requirement since the Qualification Program was developed to address IEEE 323-1971,
- however, ITT Barton has been contacted to determine the materials of construction. Based on this information, aging degradation will be evaluated.
t_
3.
DEFICIENCY CONCERN: Qualified life or replacement cycle not established.
O DISCUSSION / PROPOSED ACTION:
Qualified life and replacement cycle will be established based on aging j
analysis evaluation.
C.
DEFICIENCY CONCERN: Test Failures: Calibration.
t DISCUSSION / PROPOSED ACTION:
Out of four (4) transmitters tested, one had a deviation in calibration i
occurrence. The investigation conducted by Westinghouse on this zero calibration drift is currently being sought for a more detailed DLC review. At this time, the cause is not able to be determined.
It could have been a result of the now l
i known pin connector problem which requires soldering for its corrective action, or it could possibly relate to I
an oxidation problem of the zeroing potentiometer.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981) 2.
SCEW SNEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981) 7.0 OTNER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B Submittal, October 15, 1981) 2.
TEST REPORT WCAP 9885 - (Located in DLC EQ File IV.B.1/16) 8.0 DLC ACTION PLAN It is known, however, that the Lot 2 transmitters require their connection P n to be soldered and DLC is attempting to obtain the necessary procedures to l
i
[
accomplish this change.
l The aging analysis is being conducted on these transmitters and the replacement schedule will be established accordingly.
I LO 1
l-
~ - -
DLC TAB f 17 FRCTABf))I DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
17 FRC NUMBER (S):
41 EQUIP DESCRIPTION: Level Transmitter I
EQUIP MARK NO (S): LT-RS-151A & B MANUFACTURER:
GEMS MODEL NUMBER (S):
XM-59342 (original transmitter)
XM-36479 (replacement transmitter) 2.0 BRIEF OVERVIEW OF STATUS The original GEM level transmitters, that were located inside containment, were replaced during the Second Refueling Outage with a unit presumed to be qualified. The replacement's qualification has not been able to be established, and as a result, it will have to be replaced as soon as another qualified level transmitter can be obtained.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualification Not Established.
DEFICIENCIES / CONCERNS:
Improper test sequence, installed transmitter different from test specimen, qualification time, pressure, aging, margin, qualification information being developed.
i B.
EDS REVIEW QUALIFICATIONS STATUS:
Qualification Not Established.
DEFICIENCIES / CONCERNS:
Similarity, envelope, aging, operating time.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES /C06CERNS:
Similarity, aging, qualified life or replacement schedule, aging degradation, peak temperature / pressure enveloping, chemical O
- spray, submergence, functional testing criteria.
7 D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending O
Modification.
DEFICIENCIES / CONCERNS:
The original CEM transmitters reviewed by FRC was replaced in 1982, however, it also must be replaced because of lack of complete qualification.
4.0 NRC/FRC QUALIFICATION CATECORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE i
l 5.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-OlB DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 6.0 OTHER REFERENCE DLC DOCUMENTS
.1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B Submittal, October 15, 1981).
7.0 DLC ACTION PLAN DLC will replace the newly installed level transmitter with ones that are 6
fully qualified. A vendor search is being performed for the best available units to replace them within the time frame allotted by the recent NRC Rulemaking.
4
DLC TAB # 18 FRC TAB # _83 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
18 FRC NUMBER (S):
83 EQUIP DESCRIPTION: Level Transmitter EQUIP MARK NO (S): LT-RC-470 MANUFACTURER:
Mason-Neilan MODEL NUMBER (S):
12522 2.0 BRIEF OVERVIEW OF STATUS Based on its operating function, this instrument is required to meet the l
requirements of Reg. Cuide 1.97, Category 3.
The function of this instrument is to provide pressurizer relief tank level indication and thereby serve as a back-up to the pressurizer PORV flow indicator.
The Category 3 requirements require that the level transmitter be shown to have its manufacturer's design parameters exceed the worst case service conditions.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Modification (to be replaced).
I i
DEFICIENCIES / CONCERNS:
Standard commercial grade, with no qualification documentation.
l B.
EDS REVIEW l
QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
Standard commercial grade with no qualification documentation.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Qualification documentation deficient.
D.
DLC RE7IEW QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Qualification documentation not available.
I 4.0 NRC/FRC QUALIFICATION CATEGORY
/m
~ FRC DLC I.a EQUIPMENT QUALIFIED
)
i I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II,b EQUIPMENT NOT QUALIFIED II.c EQUIFMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXCMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Qualification document deficient.
DISCUSSION / PROPOSED ACTION:
DLC agrees that the documentation is not t
l sufficient to support qualification and s
l had previously stated that level transmitter to be replaced.
j B.
DEFICIENCY CONCERN: NUREG-0737, II.f.1; accident monitoring / pressure level.
l DISCUSSION / PROPOSED ACTION:
This referenced NUREG-0737 item is not applicable to the pressurizer relief tank level measurement.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B Submittal, October 15, 1981)
O
8.0 DLC ACTION PLAN Level transmitters will be replaced with Barton level 5 transmitters within the time frame allotted by the NRC Rulemaking.
O 4
4 j
.F O
,e-
~--,,-.--n_-
,.y
---n-..n.
n-
1 l
DLC TAB # 19 i
FRC TAB i U O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT f
1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
19 FRC NUMBER (S):
47 EQUIP DESCRIPTION: Pressure Transmitter EQUIP MARK NO (S): PT-RS-152A, 152B MANUFACTURER:
Fischer & Porter MODEL NUMBER (S):
50EP1071BCXB l
2.0 BRIEF OVERVIEW OF STATUS Although the Fischer & Porter Transmitters have a reasonable chance of being qualified for non LOCA, MSLB, and HELB affected areas, they have incurred failures during tests because of steam entry into their electronics located inside containment. They are apparently able to operate for several minutes in a steam environment.
The previously committed date of June 1982 was unable to Os be realised because qualification documentation for the replacement Barton Transmitters had not been received or reviewed to assure qualification.
It is I
)
currently anticipated that the replacement of the Fisher & Porter transmitters can be accomplished within the time frame allotted by the NRC Rulemaking.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL I
QUALIFICATIONS STATUS:
Not Qualified; will be Replaced.
DEFICIENCIES / CONCERNS:
Qualification documentation not available.
Commercial grade units.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Qualified; Replace Device.
DEFICIENCIES / CONCERNS:
The device is not qualified for the specified integrated radiation dose.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Qualification documentation not available.
p 4
m
i-DLC TAB i 19 FRC TAB f y D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
4 DEFICIENCIES / CONCERNS:
Qualification documents not available. The equipment will be replaced within the time l
frame allotted by the NRC Rulemaking.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC i
I.a EQUIPMENT QUALIFIED 1.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED 1
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal) DATED OCTOBER 15, 1981 2.
SCEW SHEETS (Reference 79-01B DLC Submittal) DATED OCTOBER 15, 1981 6.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981, Submittal).
7.0 DLC ACTION PLAN DLC is actively pursuing the appropriate qualification documentation for the replacement Barton Transmitters which have been received at the Beaver Valley Power Station but not installed pending the receipt and review of qualification documentation from the supplier.
It is anticipated that they will be installed within the time frame allotted by the NRC Rulemaking.
DLC TAB # 19 FRC TAB f 91 O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1
i 1.0 EQUIPMENT QUALIFICATION SUMMART 79-01B TAB NUMBER:
19 FRC NUMBER (S):
91 EQUIP DESCRIPTION: Pressure Transmitter EQUIP MARK NO (S): PT-RC-472 MANUFACTURER:
Fischer & Porter MODEL NUMBER (S):
50EP1031 1
2.0 BRIEF OVERVIEW OF STATUS Although the Fischer & Porter Transmitters have a reasonable chance of being.
qualified for non LOCA. MSLB, and HELB affected areas, they have incurred failures during tests because of steam entry into their electronics located inside containment. They are apparently able to operate for several minutes in a steam environment.
The previously committed date of June 1982 was unable to O
be realized because qualification documentation for the replacement Barton.
l l
Transmitters had not been received or reviewed to assure qualification.
It is currently anticipated that the replacement of the Fisher & Porter transmitters can be accomplished within the time frame allotted by the NRC Rulemaking.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Not Qualified; will be Replaced.
DEFICIENCIES / CONCERNS:
Qualification documentation not available.
Commercial grade units.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Qualified; Replace Device.
l DEFICIENCIES / CONCERNS:
The device is not qualified for the specified integrated radiation dose.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Qualification documentation not available.
DLC TAB # 19 FRC TAB # 91
~
D.
DLC REVIEW QUALIFICATIONS STATUS:
(1.b) Equipment Qualification Pending Modification.
i DEFICIENCIES / CONCERNS:
Qualification documents not available. The equipment will be replaced within the time frame allotted by the NRC Rulemaking.
4 4.0 NRC/FRC QUALIFICATION CATEGORY I
FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED i
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED l
III.a EQUIPMENT EXEMFT FROM QUALIFICATION
)
III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 INITIAL DLC REVIEW DOCUMENTS
-1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal) DATED OCTOBER 15, 1981 2.
SCEW SHEETS (Reference 79-OlB DLC Submittal) DATED OCTOBER 15, 1981 l
j 6.0 OTHER REFERENCE DLC DOCUMENTS
- 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981, Submittal).
7.0 DLC ACTION P1Aji O
l-DLC is actively pursuing the appropriate qualification documentation for the replacement Barton Transmitters which have been received at the Beaver Valley Power Station but not installed pending the receipt and review of qualification documentation from the supplier.
It is anticipated that they will be installed within the time frame allotted by the NRC Rulemaking.
DLC TAB # 20 FRC TAB # IUE O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT j
1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-OlB TAB NUMBER: 20 i
FRC NUMBER (S):
46 EQUIP DESCRIPTION: Pressure Transmitters l
EQUIP MARK NO (S):
PT-RC-402, 403, 455, 456, 457 MANUFACTURER:
ITT Barton MODEL NUMBER (S):
763, Lot 2 2.0 BRIEF OVERVIEW OF STATUS These transmitters, located inside containment, require additional review of test anomalies and are expected to be qualified. Currently pending is the soldering of their pin connectors and conducting an aging evaluation.
The qualification program for these transmitters was developed to address NUREC-0588 Cat II.
NUREG 0588 Cat II requires that the materials susceptible to aging effects should be identified and their replacement schedule be established.
l Evaluation of the qualified life of the equipment and its constituent parts and
()
determination of the replacement schedule will be performed.
3.0 REVIEWS
SUMMARY
I A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
Aging.
B.
EDS REVIEW l
QUALIFICATIONS STATUS:
Not Acceptable.
I DEFICIENCIES / CONCERNS:
Time margins and chemical spray, t
C.
FRC/NRC QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established a
DEFICIENCIES / CONCERNS:
Aging degradation, qualified life and test anomalies.
O l
4
l D.
DLC REVIEW f( -
, QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established DEFICIENCIES / CONCERNS:
Aging, qualified life and replacement schedule not established and test anomaly.
4.0 NRC/FRC QUALIFICATION CATECORY r
FRC DLC I.a EQUIPMENT QUALIFIED I
l I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION I
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED X
X l
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW
- O
[
IV.
DOCUMENTATION NOT MADE AVAILABLE 3
5.0 REVIEW OF NRC/FRC DEFICIENCIES
[
A.
DEFICIENCY CONCERN: Aging Degradation (thermal only).
DISCUSSION / PROPOSED ACTION:
Qualification Program was developed to address IEEE 323-71.
- However, ITT Barton has been contacted to determine the degradable materials.
B.
DEFICIENCY CONCERN: Qualified Life or Replacement Schedule Not Established.
DISCUSSION / PROPOSED ACTION:
ITT Barton has been contacted to identify the materials of construction
['
and based on this information the aging
[
analysis will be performed and qualified life established.
1
\\
l C.
DEFICIENCY CONCERN: Test Anomalies, Damage to the Insulation of the Lead Wire.
DISCUSSION / PROPOSED ACTION:
One difficulty experienced was the fact that the external lead wire was damaged due its environmental exposure, however, the accuracy requirements were satisfied after this wire was repaired.
..-.--.--..-.-z.._-,
_ t _, _
6.0 INITIAL DLC REVIEW DOCUMENTS m
1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal. Oct. 15, 1981) 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981. Submittal) 2.
TEST REPORT WCAP 9885 - (Located in DLC EQ File IV.B.1/20) 8.0 DLC ACTION PLAN It is known that the Lot 2 transmitters require their connection pin to be soldered and DLC is attempting to obtain the necessary procedures to accomplish this change.
ITT Barton has been contacted to determine the materials of construction.
The aging analysis will be conducted based on the nr.nufacturer's information and establish qualified life and replacement schedule will be formulated accordingly.
O I
r O
a
,.-r.~
.-..~.-r g_-
,---n b
,e n.
I' DLC TAB # 21 FRC TAB f 46 i
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
s79-01B TAB NUMBER: 21 FRC NUMBER (S):
40 EQUIP DESCRIPTION: Level Transmitter EQUIP MARK NO (S):
LT-FW-477, 487, 497 MANUFACTURER:
ITT Barton MODEL~ NUMBER (S):
386 2.0 BRIEF OVERVIEW OF STATUS Model 386 transmitters located inside containment will be replaced with Barton, Lot 5 transmitters pending receipt of adequate qualification documentation from j
the supplier.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Not Qualified.
l f-DEFICIENCIES / CONCERNS:
Chemical spray, aging, margin, replacement schedule.
The existing transmitters will be replaced with qualified transmitters.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
Similarity and qualified life.
l C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b.) Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Traceability, aging, qualified life not established, test duration, chemical spray and instrument accuracy.
O I
I D.
DLC REVIEW
[
QUALIFICATIONS STATUS:
(I.b.) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
The replacement transmitters will be installed as soon as qualification documentation has been received and qualification evaluated successfully.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION
( )-
III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW
)
IV.
DOCUMENTATION NOT MADE AVAILABLE i
5.0 REVIEW OF NRC/FRC DEFICIENCIES Several of the deficiencies pointed out by the NRC/FRC review had been recognized by DLC in its original 79-01B submittal to the NRC and it was for these reasons that DLC decided to initiate their replacement.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981)
O V
._. __=
l 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B Submittal, O
October 15, 1981) d 8.0 DLC ACTION PLAN i
The equipment will be replaced with Barton transmitters within the time frame i
allotted by the NRC Rulemaking.
i O
L l
t i
e O
l DLC TA3 # 22 FRC TAB # 52 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT l
1.0 EQUIPMENT QUALIFICATION
SUMMARY
l 79-01B TAB NUMBER: 22 FRC NUMBER (S):
52 BQUIP DESCRIPTION: Narrow Range Temperature Resistance Bulb EQUIF MARK NO (S): TRB-RC-412B, 412D, 4225, 422D, 432B, 432D,
'f I
MANUFACTURER:
Sostman i
MODEL NUMBER (S):
11834B-1 l
l 2.0 BRIEF OVERVIEW OF STATUS The applicable test report Westinghouse WCAP-9157 has a minor deficiency in that the spray duration was not identified for the Sostman RTDs. This is not viewed i
as a significant concern.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL
! O QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
The RTD's gere qualified for radiation level i
of 1 x 10, which limits the qualified life.
l The Sostman RTDs will be replaced with 1
i qualified units.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Qualification not accepted.
J DEFICIENCIES / CONCERNS:
Similarity between tested and installed not
)
documented.
Aging analysis, chemical spray, j
radiation, operating time did envelope the service conditions.
C.
FRC/NRC QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established.
DEFICIENCIES / CONCERNS:
Inadequate qualification documents, qualified i
- life, aging degradation, spray function testing and instrument accuracy criteria.
O 8
l l
h, l'
D.
DLC REVIEW
[
QUALIFICATIONS STATUS:
(I.a) Equipment qualified.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED X
I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTA5LISHED X
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED I
III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE O
EXPLANATION OF DIFFERENCES IN QUALIFICATION CATECORY:
Sostman RTDs: Test results (WCAP9157) gndicate during the radiation test, a radiation level of 1 x 10 Rads was used. The narrow range RTDs are qualified for 40 years of normal operation and also meet the i
30-second requirement for a trip function.
5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Documented evidence of qualification lacking.
DISCUSSION:
Test report WCAP-9157 did not provide detailed qualification data for spray density and duration.
Because chemical spray was performed for a portion of the test with no unsatisfactory test results and the fact the RTD assemblies have a rugged metal construction, this qualification concern is not l
significant.
lO I
B.
DEFICIENCY CONCERN: Aging degradation evaluation and qualified life based on dose rate.
DISCUSSION / PROPOSED ACTION:
Narrow range RTD qualified for 40 years.
C.
DEFICIENCY CONCERN: Criteria regarding spray density and duration not stated.
DISCUSSION / PROPOSED ACTION:
Chemical spray solution with a pH of 8.7 although slightly below the 10.5 required for the first hour is not a significant concern because of the material used in manufacture of RTD.
D.
DEFICIENCY CONCERN: Criteria regarding function testing and instrument accuracy information not included regarding worse case error under design basis accident condition.
DISCUSSION / PROPOSED ACTION:
RTDs were not calibrated during radiation exposure, however, they were operational during the entire LOCA simulation.
fs 6.0 INITIAL DLC REVIEW DOCUMENTS I
1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) i 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-OlB Submittal, October 15, 1981) 2.
AGING EVALUATION - (located in DLC EQ File IV.B.1/22)
DLC TAB i 22 FRC TAB # 53 o
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 22 FRC NUMBER (S):
53 EQUIP DESCRIPTION: Wide Range Temperature Resistance Bulb BQUIF MARK NO (S): TRB-RC-4128, 413, 420, 423, 430, 433 MANUFACTURER:
Sostman MODEL NUMBER (S):
11901B-2 l
2.0 BRIEF OVERVIEW OF STATUS l
The applicable test report Westinghouse WCAP-9157 has a minor deficiency in that the spray duration was not identified for the Sostman RTDs.
Although this is I
not viewed as a significant concern, the existing wide range Sostaan RTDs are scheduled for replacement.
3.0 REVIEWS
SUMMARY
O A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
The RTD's gere qualified for radiation level of 1 x 10, which limits the qualified life.
The Sostaan RTDs will be replaced with qualified units.
l B.
EDS REVIEW QUALIFICATIONS STATUS:
Qualification not accepted.
DEFICIENCIES / CONCERNS:
Similarity between tested and installed not documented.
Aging analysis, chemical spray, radiation, operating time did envelope the service conditions.
C.
FRC/NRC l
l QUALIFICATIONS STATUS:
(II.a) Equipment Qualification not established.
DEFICIENCIES / CONCERNS:
Inadequate qualification documents, qualified
- life, aging degradation, spray function O
testing and instrument accuracy criterion.
i
)
D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.b) Equipment qualification pending modification.
DEFICIENCIES / CONCERNS:
DLC is currently awaiting qualification test report documentation for the wide range replacement RTDs prior to installing the l
replacements.
i 4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED X
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE i
i EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
Sostman RTDs: Test results (WCAP9157) gndicate during the radiation test, a radiation level of 1 x 10 Rads was used. The dose rate was used to qualify the wide range application for approximately 12 years l
of normal operation plus 2 weeks of monitoring following a secondary system line break.
Spray duration not stated in test report.
DLC has categorized it I.b because their replacement is being scheduled.
Replacement RTDs (wide range):
Documentation being secured for assessment prior to replacement.
O
-?
J 5.0 REVIEW OF NRC/FRC DEFICIENCIES e
A.
DEFICIENCY CONCERN: Documented evidence of qualification lacking.
DISCUSSION:
Test report WCAP-9157 did not provide detailed qualification data for spray density and duration.
Because chemical spray was performed for a portion of the test with no unsatisfactory test results and the fact the RTD assemblies have a rugged metal construction, this qualification concern is not significant.
B.
DEFICIENCY CONCERN: Aging degradation evaluation and qualified life based on dose rate.
DISCUSSION / PROPOSED ACTION:
The wide range RTD qualified for 12 years but is being replaced.
C.
DEFICIENCY CONCERN: Criteria regarding spray density and duration not stated.
DISCUSSION / PROPOSED ACTION:
Chemical spray solution with a pH of 8.7 although slightly below the 10.5 required for the first hour is not a significant concern because of the material used in manufacturer of RTD.
D.
DEFICIENCY CONCERN: Criteria regarding function testing and instrument accuracy information not included regarding worse case error under design basis accident condition.
DISCUSSION / PROPOSED ACTION:
RTDs were not calibrated during radiation exposure, however, they were l
operational during the entire LOCA simulation.
I I
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) l l
7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B Submittal, October 15, 1981) 2.
AGING EVALUATION - (located in DLC EQ File IV.B.1/22) i 8.0 DLC ACTION PLAN DLC is awaiting the test report which will be evaluated before installing the
-new wide range RTD manufactuered by RDF Corporation.
t
6 DLC TAB # 23 FRC TAB 'i 53I O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
23 FRC NUMBER (S):
55 EQUIP DESCRIPTION: Tepoerature Detector (RTD)
EQUIP MARK NO (S): TRB-RS-150A, B MANUFACTURER:
Electric Thermometer Trinity Inc.
2.0 BRIEF OVERVIEW OF STATUS I
' ~
During the Second Refueling Outage, the Electric Thermometer, Trinity RTD's were replaced with Conax resistance temperature detectors.
Qualification documentation for the Conax is currently filed in the Duquesne Light Company EQ File 2024.
The Conax qualification documentation has been reviewed and is considered qualified for its application. _
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL
~
)
QUALIFICATIONS STATUS:
No Qualification Documentation Available.:
?
9 DEFICIENCIES / CONCERNS:
As a result of the lack of documentation DLC committed to replacement of the RTDs with qualified equipment.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Acceptable.
DEFICIENCIES / CONCERNS:
Item should be replaced if it cannot be
~~.,
removed from master list.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification FcodinR Modification.'
DEFICIENCIES / CONCERNS:
Documentedevddenceof' qualification inadequate.
D.
DLC REVIEW A
QUALIFICATIONS STATUS:
(I.a) Equipment Qualified.
J h
.._-_,[.
4.0 NRC/FRC QUALIFICATION CATECORY~
FRC DLC
~
l :
I.a EQUIPMENT QUALIFIED See 5.0(A) p
['
I.b
. EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED i'
II.b EQUIPMENT NOT QUALIFIED I
II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED t
.s-III.a-EQUIPMENT EXEMPT FROM QUALIFICATION III,b EQUIPMENT NOT IN TNE SCOPE OF THE QUALIFICATION REVIEW 1
IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Documented Evidence of Qualification Inadequate.
l DISCUSSION / PROPOSED ACTION:
The Electric Thermometer Trinity Inc.,
.i f f-was replaced during the Second Refueling QfJ Outage in 1982 with Conax RTDs.
d Qualification documentation for the Conax RTD is located in the Duquesne Light Company EQ File 2024.
No further action is required.
l t-
. INITIAL DLC REVIEW DOCUMENTS 6.0
\\ ~.
- 1. '-
SUMMARY
SHEETS (Reference 79-01B DLC Submittal) - Voided j
l 2.
SCEW SHEETS (Reference 79-01B DLC Submittal) - Voided g.
j,3-rN i
7.0'OiHERREFERENCEDLCDOCUMENTS
~
1.
JUSTIFICATION FOR INTERIM OPERATION - (Reference 79-01B Submittal, i
October 15, 1981) t v-(
[f e, f
/~
r
DLC TAB i 23 FRC TAB f 5 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
23 FRC NUMBER (S):
55 EQUIP DESCRIPTION: Temperature Detector (RTD)
EQUIP MARK NO (S): TRB-RS-150A, B MANUFACTURER:
Electric Thermometer Trinity Inc.
2.0 BRIEF OVERVIEW OF STATUS During the Second Refueling Outage, the Electric Thermometer Trinity RTD's were replaced with Conax resistance temperature detectors.
Qualification documentation for the Conax is currently filed in the Duquesne Light Company EQ File 2024. The Conax qualification documentation has been reviewed and is considered qualified for its application.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL
)
QUALIFICATIONS STATUS:
No Qualification Documentation Available.
DEFICIENCIES / CONCERNS:
As a result of the lack of documentation, DLC committed to replacement of the RTDs with qualified equipment.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Acceptable.
DEFICIENCIES / CONCERNS:
Item should be replaced if it cannot be removed from master list.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Documented evidence of qualification inadequate.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.a) Equipment Qualified.
A 4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED See 5.0(A)
I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION 4
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPNENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Documented Evidence of Qualification Inadequate.
DISCUSSION / PROPOSED ACTION:
The Electric Thermometer Trinity Inc.,
was replaced during the Second Refueling Outage in 1982 with Conax RTDs.
[
Qualification documentation for the Conax RTD is located in the Duquesne Light Company EQ File 2024.
No further action is required.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal) - Voided l
[
2.
SCEW SHEETS (Reference 79-01B DLC Submittal) - Voided 3
7.0 OTHER REFERENCE DLC DOCUMENTS i.
JUSTIFICATION FOR INTERIM OPERATION - (Reference 79-01B Submittal, 1.
October 15, 1981)
O t
t e-
-.u
..n.
.m.v-w--
-,,---n-,,,.-g-
--..,---v-,, - -, --
-m.
DLC TAB f 24 FRC TAB i T O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 24 FRC NUMBER (S):
1 EQUIP DESCRIPTION: Motor Operators EQUIP MARK NO (S):
VS-D-5-58,.3B MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-0 2.0 BRIEF OVERVIEW OF STATUS l
The Limitorque actuators located inside containment are mounted on the l
containment purge system's isolation valves.
These isolation valves are normally closed except for modes 5 and 6.
Because they are administrative 1y controlled in accordance with the Technical Specifications and are not required to operate during an accident condition, they are considered exempt from qualification requirements.
i h
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified, NRC exclusion taken.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Reviewed.
C.-
FRC/NRC QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established.
DEFICIENCIES / CONCERNS:
Inadequate aging degradation, qualified-life and inadequate duration for temperature, pressure exposure.
O
(;
m-D.
DLC REVIEW
- ()
QUALIFICATIONS STATUS:
(III.b) Equipment.not in the scope of qualification.
DEFICIENCIES / CONCERNS:
This equipment item should not have been reviewed by the NRC because it is considered exempt from qualification.
4.0 NRC/FRC QUALIFICATION CATECORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION EQUIPMENT QUALIFICATION NOT ESTABLISHED X
II.a II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.h EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION X
O REVIEW i
h IV.
DOCUMENTATION NOT MADE AVAILABLE i
EXPLANATION OF DIFFERENCES IN QUALIFICATION. CATEGORY:
Although DLC has always contended that these isolation valves are exempt because i
of their non-accident mitigating function, the NRC chose to evaluate their qualification status.
DLC continues to state that they are exempt from qualification and would prefer that the NRC address the exemption situation first before examining the qualification status.
5.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) -
Exempted 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) -
Exempted O
O l
DLC TAB # 25 FRC TAB # E 3 O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
25 FRC NUMBER (S):
2,3 EQUIP DESCRIPTION: Motor Operators EQUIP MARK NO (S): MOV-CH-310 MOV-RC-535, MOV-RC-536, MOV-RC-537 MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-00 2.0 BRIEF OVERVIEW OF STATUS Limitorque Test Reports 600198 and WCAP 7410L and 7744 are currently being investigated with the original supplier for their applicability.
Test reports did not identify materials.
The identification of these materials of construction for the Limitorque motor operators is being pursued with Westinghouse and Limitorque in order to conduct an independent aging evaluation.
Limitorque has stated that the valves have a qualified life of at least 40 years.
O 3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL i
QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
MOV-CH-310 not qualified for submergence, modify MCC for submergence and replace valve MOV-CH-310.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Acceptable.
DEFICIENCIES / CONCERNS:
1.
_ Similarity of tested equipment to installed equipment.
2.
Perform chemical spray analysis.
3.
Provide a thermal aging analysis.
O
C.
FPC/NRC
(-~\\
- QUALIFICATIONS STATUS
(II.a) Equipment Qualification Not Established.
DEFICIENCIES / CONCERNS:
Inadequate documentation, similarity between tested and installed equipments, aging l
degradation, qualified life / replacement schedule.
D.
DLC REVIEW i
QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not i
l Established.
l DEFICIENCIES / CONCERNS:
Similarity, aging degradation and qualified life.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED 1.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a-EQUIPMENT QUALIFICATION NOT ESTABLISHED X
X
(/
II.b EQUIPMENT NOT QUALIFIED g
\\s-II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Documented evidence of qualification is inadequate.
DISCUSSION / PROPOSED ACTION:
Applicability of the test reports 600198 and WCAP 7410L and 7744 to these operators is being pursued thru Westinghouse and Limitorque.
Ov
B.
DEFICIENCY CONCERN: Adequate similarity between installed equipment and test specimen not established.
O DISCUSSION / PROPOSED ACTION:
Tested model appears to be similar to the installed equipment as outlined by various abstracts in the test reports from Limitorque (DLC Tab 25).
Manufacturer is also being contacted to confirm applicable test reports to various operators.
C.
DEFICIENCY CONCERN: Aging degradation evaluation is inadequate.
DISCUSSION / PROPOSED ACTION:
Preliminary analysis shows that the qualified life of the identified susceptible material is greater than 40 years.
Manufacturers are being contacted to identify additional degradable materials of construction.
D.
DEFICIENCY CONCERN: Qualified life or replacement schedule not established.
DISCUSSION / PROPOSED ACTION:
Preliminary analysis shows that qualified life of identified materials is greater than 40 years,
- however, periodic replacement of the operator's lubricant will be necessary.
E.
DEFICIENCY CONCERN: Motor brake assembly not identified.
)
i DISCUSSION / PROPOSED ACTION:
The manufacturer is being contacted to provide design and materials type of details on the motor brake.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-OlB DLC Submittal, October 15, 1981)
O
t l
- l 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981, Submittal and 30-Day 1983 Response) 2.
AGING EVALUATION (Reference DLC EQ File - IV.B.1/25) 8.0 DLC ACTION PLAN The motor operator for MOV-CH-310 has been purchased on P.O. CC520 and will be l
replaced on receipt of equipment and qualification documentation from Westinghouse.
Continued efforts to identify materials of construction for operators MOV-RC-535.536,537 and demonstrate traceability are being conducted.
l-O l
)
P l
O 4
_._m,
I DLC TAB f 25 FRC TAB # 4 5 O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION SU:LdY 79-01B TAB NUMBER: 25 FRC NUMBER (S):
4,5 EQUIP DESCRIPTION: Motor Operators EQUIP HARK NO (S): MOV-CH-378, MOV-SI-865A,B C MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-003 2.0 BRIEF OVERVIEW OF STATUS Limitorque Test Reports 600198 and WCAP 7410L and 7744 are currently being investigated with the original supplier for their applicability.
Test reports did not identify materials.
The identification of these materials of construction for the Limitorque motor operators is being pursued with Westinghouse and Limitorque in order to conduct an independent aging evaluation.
Limitorque has stated that the valves have a qualified life of at least 40
)O years.
3.0 REVIEWS
SUMMARY
)
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
None.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Acceptable.
DEFICIENCIES / CONCERNS:
1.
Similarity of tested equipment to installed equipment.
2.
Perform chemical spray analysis.
3.
Provide a thermal aging analysis.
C.
FRC/NRC QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established.
DEFICIENCIES / CONCERNS:
Similarity between tested and installed equipments, aging degradation, qualified life / replacement schedule.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established.
J.-
DEFICIENCIES / CONCERNS:
Similarity, aging degradation and qualified life.
l 4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED X
X II.b EQUIPMENT NOT QUALIFIED l
II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION
[
I l
III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE l
l 5.0 REVIEW OF NRC/FRC DEFICIENCIES i
A.
DEFICIENCY CONCERN: Adequate similarity between equipment and test l
specimen not established.
DISCUSSION / PROPOSED ACTION:
Tested model appears to be similar to the installed equipment as outlined by various abstracts in the test reports J
from Limitorque. Manufacturers are also being contacted to confirm applicable test reports to various operators.
B.
DEFICIENCY CONCERN: Aging Degradation Evaluation is Inadequate.
DISCUSSION / PROPOSED ACTION:
Preliminary analysis shows that the qualified life of the identified f
susceptible materials is greater than 40 years for thermal aging analysis of identified materials. Manufacturers are i
being contacted to identify any additional degradable materials.
4
C.
DEFICIENCY CONCERN: Qualified Life of Identified Materials.
DISCUSSION /PROPCSEL ACTION:
Qualified life of identified materials is greater than 40 years,
- however, periodic replacement of the operator's lubricant will be necessary.
D.
DEFICIENCY CONCERN: Motor Brake Assembly Not Identified.
4 DISCUSSION / PROPOSED ACTION:
The manufacturer is being contacted to provide design and material type of details on the motor brake.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (30-Day 1983 Response) 2.
AGING ANALYSIS (Reference DLC EQ File - IV.B.1/25) lO 8.0 DLC ACTION PLAN DLC is attempting to establish similarity of the installed equipment to l
equipment tested.
An independent aging evaluation will be conducted for any known degradable materials present in the' unit and a replacement schedule will be established.
{
\\
l
,!O
DLC TAB # 25 FRC TAB # iRi
]
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
l 79-01B TAB NUMBER:
25 FRC NUMBER (S):
90 EQUIP DESCRIPTION: Motor Operators EQUIP MARK NO (S): MOV-SI-842 MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-00 2.0 BRIEF OVERVIEW OF STATUS DLC has committed to replacement of the inside containment isolation valve operator with an operator of Class H insulation on the motor windings.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL f ()
QUALIFICATIONS STATUS:
Qualified.
v' DEFICIENCIES / CONCERNS:
MOV-SI-842 will be replaced with an operator supplied with Class H insulation.
I B.
EDS REVIEW QUALIFICATIONS STATUS:
Acceptable.
DEFICIENCIES / CONCERNS:
1.
Similarity of tested equipment to installed equipment.
2.
Perform chemical spray analysis.
3.
Provide a thermal aging analysis.
t l
C.
FRC/NRC l
l QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Inadequate documentation, similarity between tested and installed equipments, aging
(
l degradation, qualified life / replacement i
schedule.
O("s
4 D.
DLC REVIEW O.
QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Similarity, aging degradatice end qualified life.
Inadequate qualification documents.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC j
I.a EQUIPMENT QUALIFIED 1
I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE l
5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Documented evidence of qualification is inadequate.
DISCUSSION / PROPOSED ACTION:
Documentation supplied with the replacement equipment will remedy this situation.
B.
DEFICIENCY CONCERN: Adequate similarity between equipment and test specimen not established.
DISCUSSION / PROPOSED ACTION:
Documentation supplied with the replacement equipment will remedy this situation.
C.
DEFICIENCY CONCERN: Aging Degradation Evaluation is Inadequate.
DISCUSSION / PROPOSED ACTION:
When the documentation for the replacement MOV is reviewed and O
- accepted, an independent aging evaluation will be conducted.
D.
DEFICIENCY CONCERN: Qualified life or replacement schedule not "
established.
DISCUSSION / PROPOSED ACTION:
Typically, the Limitorque's qualified life of identified materials is greater than 40 years. The manufactuer is being contacted to identify any additional degradable materials of construction.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, Oct. 15, 1981 Submittal) 8.0 DLC ACTION PLAN Motor operator MOV-SI-842 has been purchased on P.O.
C.C.
520 and will be O
replaced on receipt of equipment and qualification documents from Westinghouse.
i O
?
DLC TAB # 26 FRC TAB f 56
~
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
26 FRC NUMBER (S):
56 EQUIP DESCRIPTION: Pump Motor t
EQUIP MARK NO (S): RS-P-1A and RS-P-1B MANUFACTURER:
Ceneral Electric Company MODEL NUMBER (S):
SK6319XJ20A 2.0 BRIEF OVERVIEW OF STATUS equipment, Inside Containment Recirculation Spray Pump, meets all of the i
The qualification requirements except the qualified life and replacement assessment.
The aging analysis is currently being conducted for the lead splice and bearing lubrication.
Based on this information, the qualified life or replacement schedule can be determined.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
None.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Reviewed.
DEFICIENCIES / CONCERNS:
l l
C.
FRC/NRC QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established.
DEFICIENCIES / CONCERNS:
Equipment similarity, material aging degradation, qualified life / replacement schedule, duration.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(II.c) Equipment satisfies all requirements except qualified life or replacement schedule justified.
DEFICIENCIES / CONCERNS:
Qualified life and replacement cycle assessment.
1 4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC 1-I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED X
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT X
QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE i
EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
In the FRC/NRC review, the qualification status is classified as " Qualification O
Not Established", because of the following deficiencies:
equipment similarity, material aging degradation, qualified life / replacement schedule and peak temperature and pressure duration.
The recent DLC review has addressed all the concerns except aging analysis for the lead splice, cable insulation, and l
bearing lubrication which is currently being conducted.
The qualifiation status, therefore, has been determined by DLC to be II.c.
5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: The similarity between equipment and test specimen is not adequately established.
DISCUSSION / PROPOSED ACTION:
This deficiency has been resolved. A Certificate of Compliance from General Electric Company, dated March 27, 1975 clearly identifies the equivalency between the tested model 5K6319XJ1B and the ' model #5K6319XJ20A and states what differences existed between the two units.
B.
DEFICIENCY CONCERN: Aging degradation is not evaluated adequately.
DISCUSSION / PROPOSED ACTION:
Although the deficiency has not been
\\
removed, the aging analysis for lead splice and bearing lubricant is being i
performed.
4
--.s
=,,,,n-r,n_c w,--.~,ww,
-..,,.,,,a e-
,w-.wr-,-p-
-w.
C.
DEFICIENCY CONCERN: Qualified life or replacement schedule not established.
W DISCUSSION / PROPOSED ACTION:
Based on the results of the aging
- analysis, the qualified life and replacement schedule will be determined.
D.
DEFICIENCY CONCERN: Duration criteria regarding temperature / pressure exposure inadequate.
DISCUSSION / PROPOSED ACTION:
This deficiency has been removed through an analysis that has established the qualification on duration.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
MANUFACTURER TRACEABILITY DOCUMENTS (Reference - S & W Doc.
O
- 8700-1.10-117A) 2.
SUPPLEMENTAL ANALYSIS (DLC - EQ File IV.B.1/26) 3.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B Submittal, October 15, 1981) 8.0 DLC ACTION PLAN Duquesne Light Company is presently identifying the lubricant and bearings in -
order to evaluate aging and determine the replacement cycle.
^
O
DLC TAB # 27 FRC TAB # 3Ei
)
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
27 FRC NUMBER (S):
50 EQUIP DESCRIPTION: Accelerometer EQUIP MARK NO (S):
FE-RC-100A1,A2,B1,B2,C1,C2 FE-RC-101A1, A2, B1, B2, C1, C2 MANUFACTURER:
Endevco MODEL NUMBER (S):
2273AM20 2.0 BRIEF OVERVIEW OF STATUS Qualification test report 548-8955 results indicates that the Endevco Accelerometer is qualified.
However, the Endevco Accelerometer is a component of the Acoustical Monitoring System which includes a non-qualified component (charge amplifier 22CA-2TR).
3.0 REVIEWS
SUMMARY
C)
A.
INITIAL DLC SUBMITTAL l
QUALIFICATIONS STATUS:
Not Qualified.
i DEFICIENCIES / CONCERNS:
Qualification documentation not available, testing to be conducted by Babcock & Wilcox.
B.
EDS REVIEW l
QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
1.
Qualification information not supplied.
2.
Instrumentation for interim operation lacks qualification documentation.
{
C.
FRC/NRC i
QUALIFICATIONS STATUS:
(I,b) Equipment Qualification Pending t
Modification.
l DEFICIENCIES / CONCERNS:
Evidence of qualification documentation inadequate.
l t
{
D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.a) Equipment Qualified.
DEFICIENCIES / CONCERNS:
The accelerometer itself is qualified.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED X
I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION I
II.a EQUIPMENT QUALIFICATION NOT 3STABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT
. QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATI,0N REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
The accelerometer, a component of the Acoustical Monitoring System has been demonstrated to be a qualified component within the overall system.
5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Documented Evidence of Qualification Inadequate.
DISCUSSION / PROPOSED ACTION:
Deficiency removed, equipment was successfully tested (Qualification Test Report 548-8955).
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981)
O
7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981) 2.
TEST REPORT AETC NUMBER 548-8955 (DLC - EQ File - IV.B.1/27) 8.0 DLC ACTION PLAN Qualification testing program for the entire Acoustical Monitoring System which had been scheduled for completion ' in December 1982, has been rescheduled.
Babcock and Wilcox has submitted test plan (BAW-1755) August of 1982 to DLC for comment.
The test plan (BAW-1755) has not been accepted by the Utility User Group, thereby requiring Babcock and Wilcox to submit a new test program by February 1983.
1 I
I O
i O
DLC TAB i 27 FRCTABi]((
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
I 79-01B TAB NUMBER:
27 FRC NUMBER (S):
51 EQUIP DESCRIPTION: Charge Amplifier EQUIP MARK NO (S):
FY-RC-100A1, A2, B1, B2, C1, C2 FY-RC-101A1, A2, B1, B2, C1, C2 MANUFACTURER:
Unholtz Dickie MODEL NUMBER (S):
22CA2TR 2.0 BRIEF OVERVIEW OF STATUS The qualification test report 548-8955 results indicate the Unholtz, Dickie charge amplifier did not function satisfactory during testing at accident conditions.
It was concluded that the long term functional capability of the charge amplifier cannot be assumed following a design basis. accident.
It has been recommended that the Charge Amplifier be relocated outside containment exceeding 200 feet limitation required for proper operation. A new p)g test plan has been required from Babcock and Wilcox including both design change i,
s and use of new components.
)
R_EVIEWS
SUMMARY
3.0 E
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
Qualification documentation not available; testing to be conducted by Babcock and Wilcox.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
1.
Qualification information not supplied.
2.
Alternate instrumentation for interim operation unqualified.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
()
DEFICIENCIES / CONCERNS:
Documented evidence of qualification inadequate.
t
D.
DLC REVIEW
[#I QUALIFICATIONS STATUS:
(I b) Equipment Qualification Pending
\\"
Modification.
DEFICIENCIES / CONCERNS:
Charge amplifier failed during testing under accident conditions and can only be expected 4
to remain operable for a few minutes after the initiation of a DBE.
Modifications will have to be made.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b
. EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED I
III.a EQUIPMENT EXEMPT FROM QUALIFICATION
(
III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION j
REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE l
i l
l 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Documented Evidence of Qualification Inadequate.
DISCUSSION / PROPOSED ACTION:
Charge amplifier failed during testing under accident conditions.
The relocation of the charge amplifier or replacement is being considered.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981)
O l
r-7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981) 2.
AETL (Report #548-8955 DLC EQ File IV.B.1/27) l 8.0 DLC ACTION PLAN Qualification testing program scheduled for completion in December 1982 has been rescheduled.
Babcock and Wilcox has submitted test plan (BAW-1755) August of f
1982 to DLC for comment. The test plan (BAW-1755) has not been accepted by the Utility User Group, thereby requiring Babcock and Wilcox to submit a new test program by February 1983.
DLC is closely following their developments in order to be able to utilize a qualified monitoring system.
l-O 1
1 0
=
l O
INTRODUCTION FOR:
DLC TAB 28 FRC TABS 677,8,9,45,54,60 Equipment Tab Number 2f[ includes equipment associated with both the cold shutdown and NUREG 0737. TMI Action Plan issues. Duquesne Light Company continues to consider the equipment needed for cold shutdown of the plant exempt from qualification as discussed in the October 15, 1981 Qualification Program Submittal.
In regard to the NUREG 0737 items, Duquesne Light Company has continued to review the qualification status for the various equipment that been added, modified, or possibly exempted. Any equipment added as part of NUREG 0737 programs will be identified in the DLC 90-Day Response to the.NRC Rulemaking.
V t
e l
O
DLC TAB # 28 FRC TAB # E 7,8,9,60 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT l
1 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-V B TAB NUMBER:
28 FRC NUMBER (S):
6,7,8,9,60 EQUIP DESCRIPTION: Motor Operators (for 6,7,8,60)
Pump Motors (for 9)
EQUIP MARK NO (S): See Table 28-1 MANUFACTURER:
See Table 28-1 MODEL NUMBER (S):
See Table 28-1 2.0 BRIEF OVERVIEW OF STATUS This equipment associated with the Residual Heat Removal System is considered exempt from qualification.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL j
QUALIFICATIONS STATUS:
Exempt From Qualification.
DEFICIENCIES / CONCERNS:
i B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Reviewed.
DEFICIENCIES / CONCERNS:
(
l l
C.
FRC/NRC
^
QUALIFICATIONS STt.TUS:
(II.a) Equipment Qualification Not Established.
DEFICIENCIES / CONCERNS:
See Table I.
D.
DLC REVIEW l
QUALIFICATIONS STATUS:
(III.a) Equipment Exempt From Qualification.
DEFICIENCIES / CONCERNS:
DLC considers the equipment to be exempt from qualification requirements.
I 4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED
-X II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED X
III.a EQUIPMENT EXEMPT FROM QUALIFICATION III b EQUIPMENT NOT IN THE SCOPE OF T!!E QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
With the issuance of Supplement 3 of IEB 79-01B, the NRC ' has determined the review of environmental qualification for all equipment requirement to achieve s
and maintain the plant in cold shutdown condition, is not within the scope of
)-
this report.
The equipment used in the Residual Heat Removal system can be classified under this category. Beaver Valley Unit 1 is licensed for a Hot Standby basis and is not required to have a Class IE qualified path to cold shutdown.
For this reason, the equipment listed for the RHR system is considered to be exempt from qualification.
The recent NRC Rulemaking has continued to defer cold shutdown equipment qualification consideration.
TABLE 28-1 DLC # 28 FRC i 5 7,8,9,60 i
ITEM:
RHR System Components:
NRC NOTED FRC TAB f EQUIPMENT MARK f EQUIPMENT TYPE MANUFACTURER MODEL #
DEFICIENCY
- 6 MOV-CC-112 (SMB 3eries)
Motor Operators Limitorque SMB-000 1
7 MOV-Ril-611 and RH-758 Motor Operators Limitorque SMB-00 1
8 MOV-R2-720A, B Motor Operaters Limitorque SMB-2 1,2,3,4
~ 9 RH-P-1Ab1B Pump Motors tJestinghouse S070F67868 1,2,3,4 i
-s
\\
60 MOV-RH-700 and RH-701 Motor Operators Limitorque.
SMB-1 1,2,3,4,7, 8,9,10,11, 12 s
- Legend v
1.
Documented Evidence'of Qualification Adequate 2.
AdequJte Similarity Petween Equipment'and. Test Specis'en Established 3.
Aging: Degradation Evalu'ated Adequately
,l 4.
Qualified life or Replacement' Schedule Established (If Required) 5.
Program Established to' Identify Afing Degradation
\\
y 6.
Criteria Regarding Aging Simulatioh Satiefied (If Requited) 7.
Criteria Regarding Temperature / Pressure Exp'osure:
o Peak Temperature Adequate' t
<m 7:sk Pressure Mequate o
Duratloa Adequate '
Required, Profile' Enveloped Adequately o
j o
Steam Exposure (If Rettired) Adeq6 ate ?
8.
Criteria Regarding Spray Satisfied
, x 9.
Criteria Regarding Submergence Satisfied 1
10.
CrPeria Regarding Radiation Satisfied
- 11. ' 'Crite.ria Regarding Testsse<1uence Satisfied s
12.
Criteria Regarding Jest Failures or Severe Anomalies (If Any) Satisfied
~
13.
Criteria Regarding Functional. Testing Satisfied-14.
Criteria Regarding Instrument' Accuracy Satisfied f
15.
Test Duration Margini(I hour + Function Time) Satisfied x 16.
Criterie Regarding Margins Satisfied (NUREG-0588, Cat. I) N r
4 DLC.,-
4 x
u t
x-r,g es DLC TAB i 28 FRC TAB i U o'
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
1 79-01B TAB NUMBER: 28 i
FRC NUMBER (S):
45 EQUIP DESCRIPTION: Pressure Transmitter EQUIP MARK NO (S): PT-RC-444 MANUFACTURER:
Fischer and Porter MODEL NUMBER (S):
50EP1041 2.0 BRIEF OVERVIEW OF STATUS This equipment, the intermediate range pressure transmitter, is exempt from qualification because it is backed-up by redundant wide range pressure transmitters.
3.0 REVIEWS
SUMMARY
~
A.
INITIAL DLC SUBMITTAL LO QUALIFICATIONS STATUS:
Exempt From Qualification.
,9 DEFICIENCIES / CONCERNS:
'l' I
B.
EDS REVIEW t' >
QUALIFICATIONS STATUS:
Not Reviewed.
h, b
DEFICIENCIES / CONCERNS:
/b/,
C.
FRC/NRC
(
l
-QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending L
'e L
Modification.
3 s
DEFICIENCIES / CONCERNS:
Documented evidence of qualification
,e inadequate.
ly rr.
D.
DLC REVIEW
_ -f QUALIFICATIONS STATUS:
(III.a) Equipment Exempt From Qualification.
O s
! v
- Y Q-p?#
4
. ~
' + - ~,
._-- _ _ _ _.._._ __ _ _ - ~ _ __
l 4
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED i
1.b EQUIPMENT QUALIFICATION FENDING MODIFICATION X
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED 1
II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT "1
j QUALIFIED LIFE OR REPLACI! MENT SCHEDULE JUSTIFIED l
III.a EQUIPMENT EXEMPT FROM QUALIFICATION I
III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION i
REVIEW
.l IV.
DOCUMENTATION NOT MADE AVAILABLE 1
i I
EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
i The tab referenced above provides input to the subcooling monitor. The pressure inputs consist of FT-RC-444. PT-RC-402, and PT-RC-403.
The level of redundancy cf the pressure input to the subcooling monitoring is apparent.
The two pressure transmitters, PT-RC-402 and PT-RC-403 provide necessary redundancy in the event of the failure of PT-RC-444 (Reference - Attached FRC Tab #45).
The i
failure of the ' PT-RC-444 would in no way degrade the input to the subcooling monitor. The justification and the failure mode effects analysis contained in the two attachments referenced in FRC Tab #45.. are still deemed as applicable and adequate.
l
(
5.0 INITIAL DLC REVIEW DOCUMENTS l
I 1.
.SCEW SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981)
I 6.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR INTERIM OPERATION - (Reference 30-day 1983 Response) i l
[
l l
LO I
s nr,n..r w
,----,,,a+,-,-n~,.
DLC TAB f 28 FRC TAB # h DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
28 FRC NUMBER (S):
54 EQUIP DESCRIPTION: Thermocouples EQUIP MARK NO (S):
TC2,3,5,6,20,22.23 and 24 MANUFACTURER:
Control Products Corporation MODEL NUMBER (S):
Not Stated.
1 2.0 BRIEF OVERVIEW OF STATUS This equipment, incore thermocouples, is exempt from qualification because they are backed-up by the hotleg and coldleg RTD's.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Exempt From Quelification.
DEFICIENCIES / CONCERNS:
i B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Reviewed.
DEFICIENCIES /CCNCERNS:
C.
FRC/NRC QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established DEFICIENCIES / CONCERNS:
Documented evidence of qualification inadequate.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(III.a) Equipment Exempt From Qualification.
O
4 4.0 NRC/FRC QUALIFICATION CATECORY FRC DLC I.a EQUIPMENT QUALIFIED 1.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED X
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION X
i III b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 1
l EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
l The tab referenced above provides input to the subcooling monitor.
The i
temperature indication into the subcooling monitor is supplied by the referenced eight thermocouples, two reactor coolant hotleg wide range RTDs, and two reactor coolant coldleg wide range RTDs.
The level of redundancy of the temperature inputs to the subcooling monitor is apparent.
The temperature rendundancy is provided by two wide range RTDs in the hotleg and by two wide range RTDs in the coldleg.
The in-core thermocouples provide a third level of redundsucy.
The failure of the in-core thermocouples would in no way degrade the input to the subcooling monitor. The justification and the failure modes effects analysis
(
contained in the - two attachments reference FRC Tab #54, are still deemed as applicable and adequate.
(
5.0 INITIAL DLC REVIEW DOCUMENTS 1.
SCEW SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981) 6.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR INTERIM OPERATION = (Reference 30-day 1983 Response) t l
I l!O l
DLC TAB f 29 FRC TAB f 8J DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
29 FRC NUMBER (S):
81 EQUIP DESCRIPTION: Terminal Blocks EQUIP MARK NO (S): Not Assigned MANUFACTURER:
Marathon MODEL NUMBER (S):
1500 Series 2.0 BRIEF OVERVIEW OF STATUS Marathon terminal blocks, Model 1500 Series, are qualified for use outside of containment.
Duquesne Light Company EQ File #2064 contains the qualification documentation for this equipment item.
3.0 REVIEWS
SUMMARY
()
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
Loose screws - elongation due to thermal i
expansion.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Acceptable.
DEFICIENCIES / CONCERNS:
Qualified Li.e.
I C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment qualification pending modification.
i DEFICIENCIES / CONCERNS:
Inadequate steam exposure, loose screws and test anomalies.
D.
DLC REVIEW D)
(._,
QUALIFICATIONS STATUS:
(I.a) Equipment Qualified.
i
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED X
I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
The difference in the qualification assessment was due to the result of an additional test being conducted with more applicable lower temperature s_,)
requirements. The test conducted at lower temperature level reduced the thermal expansion and loose screw concerns.
5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Inadequate steam exposure.
DISCUSSION / PROPOSED ACTION:
Materials used in construction of terminal blocks have a low affinity for water, therefore, possibility of failure due to steam condensation effects are minimal.
B.
DEFICIENCY CONCERN: Loose screws.
DISCUSSION / PROPOSED ACTION:
Test results show that screws remained tight during the test.
See Section 4.0 of Test Report #16807-82N.
C.
DEFICIENCY CONCERN: Thermal expansion of 12 point terminal block versus 4 point terminal block.
/
,\\
' \\- I DISCUSSION / PROPOSED ACTION:
A supplemental analysis indicates that the amount of differential expansion of terminal strip and mounting material is insignificant.
_ =. _. __
f i
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
SUPPLEMENTAL ANALYSIS (DLC - EQ File #2064) 2.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981) 3.
TEST REPORT (DLC EQ File - VB1.1.2) 4 l
l O
)
I r
i lO
DLC TAB # 3_0,0 FRC TAB # 3 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-OlB TAB NUMBER:
30 FRC NUMBER (S):
78 EQUIP DESCRIPTION: Cable Splice EQUIP MARK NO (S): N/A MANUFACTURER:
Okonite MODEL NUMBER (S):
T95 T35, Tape O
NO ADDITIONAL REVIEW WAS CONDUCTED i
BECAUSE EQUIPMENT IS CONSIDERED QUALIFIED 1
O
s-m4--.
s-b 4
__a-
,i
_m.a.
ag
_A A
2 m a A.
a 2.0 NRC/FRC QUALIFICATION CATECORY FRC DLC I.a EQUIPMENT QUALIFIED X
I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT-r QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED I
III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE O
3 O
(
).
~ -.. -. -.,
DLC TAB # 31 FRC TAB # 77 O
"~#
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-OlB TAB NUMBER: 31 FRC NUMBER (S):
77 EQUIP DESCRIPTION: Cable Splice Kit EQUIP MARK NO (S): Not Assigned MANUFACTURER:
Kerite i
MODEL NUMBER (S):
Putty-Biseal 3 Tape 2.0 BRIEF OVERVIEW OF STATUS The Duquesne Light Company replaced the previously installed splice with a qualified splice. The qualification documentation for the replacement splice is located in Duquesne Light Company EQ File #2025.
3.0 REVIEWS
SUMMARY
()
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
Duquesne Light Co. committed to replace i
during the Second Refueling Outage because of radiation and temperature service conditions concerns.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Acceptable.
DEFICIENCIES / CONCERNS:
State model number, peak accident temperature, relative humidity, inadequate thermal evaluation, inadequate qualification method.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Peak temperature inadequate, criteria regarding radiation unsatisfactory.
OV D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.a) Equipment Qualified. Modification Complete.
DEFICIENCIES / CONCERNS:
Replaced during Second Refueling Outage, 1982
. - _ _ _ =
J 4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC
-I.a EQUIPMENT QUALIFIED See 5.0(A) 1.b EQUIPMENT QUALIFICATION PENDING MODIFICATION l
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED l
II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEP2 QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION j
III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0. REVIEW OF iiRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Peak temperature inadequate.and criteria regarding O.-
radiation unsatisfactory.
DISCUSSION / PROPOSED ACTION:
Equipment item was replaced during Second Refueling Outage, so this concern has been eliminated.
i 6.0 INITIAL DLC REVIEW DOCUMENTS
-1.
SUMMARY
SHEETS (Reference 79-OlB DLC Submittal) - VOIDED 2.
SCEW SHEETS (Reference 79-OlB DLC Submittal) - VOIDED l
I I
7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981, Submittal)
O
_J
DLC TAB # 32 FRC TAB # W s
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 32 FRC NUMBER (S):
74 EQUIP DESCRIPTION: Control Cable EQUIP MARK NO (S): Various MANUFACTURER:
G.E.
MODEL NUMBER (S):
Vulkene 57275 2.0 BRIEF OVERVIEW OF STATUS Some of the G.E. Vulkene Model #57275 SIS Wires were replaced during the 2RFO.
The remaining SIS wire, mainly inside MCC's and possibly on locally mounted junction boxes for air operated valves will be replaced if found.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL O
QUALIFICATIONS STATUS:
Not Qualified.
)
DEFICIENCIES / CONCERNS:
Qualification information not available.
Plant modifications to replace SIS Wire.
i B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
Applicability of referenced test report, operating time and temperature, analysis for qualification, and radiation.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Documented evidence of qualification inadequate.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Documented evidence of qualification is inadequate, radiation, temperature.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC
.I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Documented evidence of qualification inadequate.
f%()
DISCUSSION / PROPOSED ACTION:
The referenced test report F-C-3781-1 is for an A-C motor control center manufactured by Allis Chalmer 3
Corporation.
The tesi report did not identify the use of G.E.
Vulkene model 57275 cable in Allis Chalmer's MCC. The G.E. Vulkene either has been or will be replaced if it is found in harsh areas of the plant.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal. Oct. 15, 1981) 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981, Submittal) 2.
TEST REPORT FC-3781 - (Reference DLC EQ File VBl.6.3)
(}
8.0 DLC ACTION PLAN Any G.E.-Vulkene cable found in the plant will be replaced.
=
h 1
DLC TAB # 33 FRC TAB i T3'
- O
~
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION i
REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-OlB TAB NUMBER:
33 FRC NUMBER (S):
73 EQUIP DESCRIPTION: Electric Cable EQUIP MARK NO (S): Not Stated MANUFACTURER:
General Electric Company
)
MODEL NUMBER (S):
Vulkene Supreme 57279 2.0 BRIEF OVERVIEW OF STATUS General Electric SIS Wire Vulkene Supreme Model 57279 has been categorized by DLC as.I.a (Equipment Qualified).
The noted deficiency of similarity between installed equipment and test specimen has been established.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified.
j B.
EDS REVIEW l'
i QUALIFICATIONS STATUS:
Not Reviewed.
E C.
FRC/NRC
(
-QUALIFICATIONS STATUS:
(II.a) Equipment' Qualification Not Established.
i DEFICIENCIES / CONCERNS:
Inadequate similarity between installed equipment and tested specimen.
l D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.a) Equipment Qualified.
[
l i.O L
.. +
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC X
I.a EQUIPMENT QUALIFIED I.b-EQUIPMENT QUALIFICATION PENDING MODIFICATION X
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE EXPLANATION OF DIFFERENCES IN -QUALIFICATION CATECORY:
The difference in qualification category was due to the establishment of
{
similarity between installed equipment and tested specimen.
3 5.0 REVIEW OF NRC/FRC DEFICIENCIES i
A.
DEFICIENCY CONCERN: Inadequate similarity between installed equipment and tested specimen.
DISCUSSION / PROPOSED ACTION:
Similarity was established by information collected from plant specific references and the manufacturer's product data sheet WCD-380.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981)-
7.0 OTHER REFERENCE DLC DOCUMENTS 1.
MANUFACTURER TRACEABILITY DOCUMENTS (DLC EQ File IV.B.1/33) s
a O
f DLC TAB #
4 l
l t
f NO O
EQUIPMENT HAD BEEN ASSIGNED mes.
TO THIS TAB NUMBER l0
~
DLC TAB # 35 4
FRC TAB f 65,66,67 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
35 FRC NUMBER (S):
65, 66, 67 EQUIP DESCRIPTION: 480V MCC's EQUIP MARK NO (S):
MCC-1-E3, E4, ES, E6, and E12 MANUFACTURER:
Allis Chalmers 2.0 BRIEF OVERVIEW OF STATUS No radiation testing was perfo rmed, however, a radiation analysis of the materials shows that MCC's are qualified.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified.
()
DEFICIENCIES / CONCERNS:
Radiation and aging analysis program l
on-going.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Reviewed.
l l
DEFICIENCIES / CONCERNS:
l C.
FRC/NRC 1
QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established.
DEFICIENCIES / CONCERNS:
Documented evidence of qualification inadequate.
Similarity between test equipment and installed equipment, aging evaluation inadequate.
Qualified life or replacement schedule not established, criteria regarding radiation not satisfied.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(II.c) Equipment Satisfies all Requirements Except Qualified Life or Replacement
()
Schedule.
DEFICIENCIES / CONCERNS:
Control transformer needs identified as to construction type.
i l
~~
i 4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED i
I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION l
II.a EQUIPMENT QUALIFICATION NOT ESTAtLISHED X
f II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT X
QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED l
l III.a EQUIPMENT EXEMPT FROM QUALIFICATION i
III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW l
i IV.
DOCUMENTATION NOT MADE AVAILABLE i
i EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
i i
The difference in qualification category is due to the fact that the overall MCC's, except for the control transformers, are qualified for accident j
conditions. The radiation values, determined by analysis (letter 17244), exceed
- the required values.-
The constituent parts of the control transformer being copper, pgper and varnish (Memo #13386.18), are acceptable up to radiation level of 1 x 10 Rads.
2 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Docmented Evidence of Qualification Not Established.
DISCUSSION / PROPOSED ACTION:
FRC Test #C3781-1 performed shows operability of MCC's under accident conditions, temperature, heat and pressure.
B.
DEFICIENCY CONCERN: Similarity Between Test Equipment and Installed j
Equipment.
DISCUSSION / PROPOSED ACTION:
Wiring modifications were made to installed units.
Tested units are similar to installed MCC's except for the epoxy molded control ~ transformer (RE: Telecon Brunner to Dunn 10-29-80).
9
--v--
c W,, - -, +,,
v.,,,, -, -
,--,s,
,,,,,,w,,e-e.,--,-,--------,---->---,r s
n e-
C.
DEFICIENCY CONCERN: Aging Evaluation Inadequate.
(J' DISCUSSION / PROPOSED ACTION:
On-going analysis will establish aging degradation of identified constituent parts.
Materials identified are as per letter #17244.
D.
DEFICIENCY CONCERN: Qualified Life or Replacement Schedule.
1 I
DISCUSSION / PROPOSED ACTION:
Replacement schedule to be based upon outcome of aging analysis of individual parts.
E.
DEFICIENCY CONCERN: Criteria Regarding Radiation not Satisfied.
f DISCUSSION / PROPOSED ACTION:
A survey conducted of organic material's i
and radiation exposure experienced by these MCC's, showed that there will be minimumal effect on the enclosed materials.
The Allis Chalmers-MCC are qualified I-material of constructign by analysis to 1x 10 Rads, which ig greater than required value of 1 x 10 Rads.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, Oct. 15, 1981) i 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B Submittal, October 15, 1981) 2.
CORRESPONDENCE WITH MANUFACTURER (Reference EQ File - IV.B.1/35 Letter 17244) 8.0 DLC ACTION PLAN DLC is currently consulting with the control transformer manufacturer for a materials identification in order that an aging evaluation can be performed on this one constituent part to complete the qualification documentation.
i i
DLC TAB # 36 FRC TAB i 26,27,28 O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
i 79-01B TAB NUMBER: 36 FRC NUMBER (S):
26, 27, 28 EQUIP DESCRIPTION: Solenoid Valves EQUIP MARK NO (S):
SOV-BD-100A,B,C, SOV-FW-102 SOV-FW-103A,B SOV-MS-105A B MANUFACTURER:
The Automatic Switch Company MODEL:
HP-8320A6, HPX8320A26 2.0 BRIEF OVERVIEW OF STATUS During the Second Refueling Outage. Duquesne Light Company replaced the previously installed unqualified ASCO Models HP-8320A6 and HPX8320A26 with new qualified ASCO Models NP-8320A187E and NP-8320A189E.
Qualification documentation for the replacement solenoid valves is filed in the Duquesne Light Company EQ File #2008 and #2022.
p 3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL' QUALIFICATIONS STATUS:
Qualification Documentation was not Available.
DEFICIENCIES / CONCERNS:
As the result of the lack of documentation, Duquesne Light Company committed to replacement of these particular ASCO Solenoid Valves with qualified Solenoid Valves.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Acceptable.
DEFICIENCIES / CONCERNS:
EDS questioned the original equipment's type of enclosure for 100% humidity environment.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Documented evidence of qualification D.
DLC REVIEW 1
QUALIFICATIONS STATUS:
(1.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Conduit seal installation.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION See 5.0(A)
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Documented evidence of qualification inadequate.
DISCUSSION / PROPOSED ACTION:
Deficiency of unqualified models was corrected by replacement with qualified models during Second Refueling Outage.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal) - Voided 2.
SCEW SHEETS (Reference 79-01B DLC Submittal) - Voided 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B Submittal, October 15, 1981) 8.0 DLC ACTION PLAN r-All attempts are being made by Duquesne Light Company to qualify and install the conduit seals within the time frame allotted by the recent NRC Rulemaking.
O w
--w-e
~ - - - - +-
--w----
c-
--*w ey---
--- +
?
DLC TAB # 37 FRC TAB # 24,25
($)
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT l
1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-OlB TAB NUMBER:
37 FRC NUMBER (S):
24 & 25 EQUIP DESCRIPTION: Solenoid Valve EQUIP MARK NO (S):
SOV-CH-204, S0V-SI-884A,B C MANUFACTURER:
ASCO MODEL:
LB-831654. LB-31924 2.0 BRIEF OVERVIEW OF STATUS During the Second Refueling Outage. DLCO replaced the previously installed ASCO Model LB-831654 and LB31924 with the qualified ASCO Model NP831655E.
Qualification documentation is filed in Duquesne Light Company's EQ File #2044.
3.0, REVIEWS
SUMMARY
\\- '
A.
INITIAL DLC SUBMITTAL i
QUALIFICATIONS STATUS:
No Qualification Information Available.
I DEFICIENCIES / CONCERNS:
Radiation test deficiency.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Acceptable.
DEFICIENCIES / CONCERNS:
Qualification data and SCEW sheets do not match.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Inadequate documented evidence of qualification.
A L
D.
DLC REVIEW QUALIFICATIONS STATUS:
(1.b) Equipment Qualification Pending Modification (a qualified replacement has been installed).
i DEFICIENCIES / CONCERNS:
Conduit seal installation.
f 4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I
I.a EQUIPMENT QUALIFIED l
1.b EQUIPMENT QUALIFICATION PENDING MODIFICATION See 5.0(A)
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED l
III.a EQUIPMENT EXEMPT FROM QUALIFICATION.
III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV. -
DOCUMENTATION NOT-MADE AVAILABLE i
5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Inadequate documented evidence of qualification.
DISCUSSION / PROPOSED ACTION: The unqualified models wi:re replaced with qualified Model NP-831655E during Second Refueling Outage.
Qualification documentation is in DLC EQ File #2044.
6.0 INITIAL DLC REVIEW DOCUMENTS l
l 1.
SUMMARY
SHEETS (Reference 79-018 DLC Submittal, October 15, 1981) -
I Voided I
2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) -
Voided l
- t
7.0 OTHER REFERENCE DLC DOCUMENTS O
1.
JUSTIFICATION FOR CONTINUED OPERATION (Reference 79-01B DLC Submittal, Oct. 15. 1981) 8.0 DLC ACTION PLAN All attempts are being made by Duquesne Light Company to qualify and install the conduit seals within the time frame allotted by the recent NRC Rulemaking.
f
.O i
l llO
DLC TAB # 38 FRC TAB # 30i O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER:
38 FRC NUMBER (S):
58 EQUIP DESCRIPTION: Limit Switches EQUIP MARK NO (S): LMS-BD-100A, B, C MANUFACTURER:
NAMCO MODEL NUMBER (S):
D2400X 2.0 BRIEF OVERVIEW OF STATUS The originally installed NAMCO Limit Switches Model D2400X, which are located outside containment, were replaced with a qualified NAMCO Model EA180 Series during the Second Refueling Outage.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
No Qualification Documentation Available.
DEFICIENCIES / CONCERNS:
As a result of the lack of documentation, DLCO committed to the replacement of this i
item.
l B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Acceptable.
DEFICIENCIES / CONCERNS:
Recommendation is to replace these switches.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification DEFICIENCIES / CONCERNS:
Documented evidence of qualification inadequate.
l D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending 7--)g Modification.
(_,
l DEFICIENCIES / CONCERNS:
The replacement limit switches are qualified.
When a qualified interface seal becomes available, the seal will be installed.
4.0 NRC/FRC QUALIFICATION CATECORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION See 5.0(A)
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED l
II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT l
QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED f
III.a EQUIPMENT EXEMPT FROM QUALIFICATION l
l III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION l
REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Documentation of Qualification Information Inadequate.
DISCUSSION / PROPOSED ACTION:
Deficiency corrected by replacement of I
these switches during Second Refueling Outage.
Documentation for the replacement limit switch is located in the Duquesne Light Company EQ File
.f2021.
f 6.0 INITIAL DLC REVIEW DOCUMENTS l
1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal) - VOIDED 2.
SCEW SHEETS (Reference 79-01B DLC Submittal) - VOIDED l
7.0 OTHER REFERENCE DLC DOCUMENTS
.1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-018. October 15, 1981. Submittal) l 8.0 DLC ACTION PLAN s
All attempts are being made by Duquesne Light Co'pany to qualidy and install the a
conduit seals within the time frame allotted by the recent NRC Rulgaaking.
..s
DLC TAB f 39-FRC TAB # E O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 39 FRC NUMBER (S):
84 EQUIP DESCRIPTION: Limit Switch EQUIP MARK NO (S): LMS-FW-103A, B MANUFACTURER:
NAMCO MODEL NUMBER (S):
EA740-2000 2.0 BRIEF OVERVIEW OF STATUS The original NAMCO limit switches, which were installed, had a concern with its electrical interface (conduit seal).. DLC is continuing in its efforts to find a qualified seal and will install at the first opportunity.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified.
i DEFICIENCIES / CONCERNS:
Electrical interface (conduit seal).. A qualified seal will be installed as soon as i
qualified seal is available.
l f
B.
EDS REVIEW QUALIFICATIONS STATUS:
Acceptable.
DEFICIENCIES / CONCERNS:
Electrical interface (conduit seal).
Applicability of referenced test report.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification DEFICIENCIES / CONCERNS:
Inadequate steam exposure.
,q D.
DLC REVIEW
'V QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Electrical interface (conduit seal). A qualified seal is needed to eliminate steam migration into limit switch housing.
29 '
4
-(.
d' 4.0 NRC/FRC QilAt t'ysCATION CATECORY b
! FRC DLC G
1 I.a EQUIPMENT QUALIFIED 1
I.b EQUIPMENT QUALIFICATION FENDING P.0DIFICATION..
X X
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED.,
II.b EQUIPMENT NOT QUALIFIFD
\\
II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT l
l QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED l
\\
l III.a EQUIPMENT EXEMPT FROM QUALIFICATl0N I
III.b EQUIPMENT NOT IN THE SCOPE OF THE QDALIFICATIO6.
l REVIEW u
IV.
DOCUMENTATION NOT MADE AVAILAl}LE t
5.0 REVIEW OF NRC/FRC DEFICIENCIES
-A.
DEFICDNCY ' CONCERN: Inadequate Steam Expo nye.'
DISCUSSI0N/ PROPOSED ACTION:
,A qualified conduit sea.l'will prevent l
steva from ; migrating'into limit switch - - :-,
j thoising.
A f qualifie'd condui':
seal
[
sysum will be installed 'when seal testing; harr been able to - demonstrate r
qualification.
7
[
u<'...
I
[
6,0 INITIAL DLC REVIEW DOCtIMENTS
SUMMARY
SI:'EETS (Reference 79-OlB DLC Submittal',' October 15, 1981) 2 SCEW SdEETS.(Reference 79-01B DLC Submittal, cetoer,15, Jo81)
?,,
~
l 3
9
~
? 7.0 OTHER REFERENCE DLC COCi!MENTS _.
1.
JUSTIFICATION FOR CONTINUED OPERATICN ~- (Referer.ce 79-01B,~0ctobe,r-15,'
1981, Submittai) f; 2
c-~..
3 s
8.0 -DLC ACTION PLAN jr 1
Q' l
All attempt:: are being made by Duqucane Light Cr.mpany to qualify and install the conduit seals within the time frame alloitted by'the recent'NRC Rulemaking.
~
T..
,a s
s s
{
jf ',
s y
,y l
.d' L,
./ --
s
/
y
=
ya
e ' ';
~e DLC TAB i M
~
.j FRC TAB # 39,43 t,O.
~
=
,,.?
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT i<
-vr
/;
.1.0 EQUIPMENT QUALIFICATION
SUMMARY
$~
79-01B TAB NUMBER: 40 FRC NUMBER (S):
39, 43
'N +
EQUIP DESCRIPTION:
Flow Transmitter
- /; ' p/
l EQUIP MARK NO (S):
FT-FW-100A,B,C and FT-RW-102A,B yn3 j, t.,-
/ '
MANUFACTURER:
Fischer and Porter MI
' O.J' '
MODEL NUMBER (S):
10B2496PBBABDB q:,
j
~
'- % 2.0 ' BRIEF OVERVIEW OF STATUS f
f-Previous-review of the qualification status of these transmitters has resulted in a lack of documentation being made available.
As a result, these transmitters are scheduled to be replaced within the time frame allotted by the NRC Rulemaking.
w w
' N,s 3.0 EVIFWS
SUMMARY
n A. ' INITIAL DLC SUBMITTAL
]
~~
l N
! Y. >.
QUALIFICATIONS STATUS:
Not Qualified.
r I[/ ' Y DEFICIENCIES / CONCERNS:
Qualification documentation not available.
f b
Commercial grade units.
- o. -
s a
B.
EDS REVIEW
~
. QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
The device is not qu111fied for the specified integrated radiation dose.
FRC/NRC C.
A./
QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending T
Modification.
.7
~
DEFICIENCIES / CONCERNS:
Qualification documentation not available.
1 D.
DLC REVIEW j
,[
w~~'
QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
- i. Cm DEFICIENCIES / CONCERNS:
The existing equipment's qualification j
'j documentation for radiation, temperature and H
pressure as well as aging evaluation
[
requirements has not been obtained.
m-
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMdNT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981)
[
2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981)
)
'i 6.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15.,
1981, Submittal) 7.0 DLC ACTION PLAN DLC is actively pursuing the appropriate qualification documentation for the replacement Barton Transmitters which have been received at the Beaver Valley Power Station, but not installed pending the receipt and review of qualification j
documentation from the supplier.
It is anticipated that they will be installed l
within the time frame allotted by the NRC Rulemaking.
l O I
DLC TAB # 41 FRC TAB # 2 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION
'~
REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-OlB TAB NUMBER: 41 FRC NUMBER (S):
37 EQUIP DESCRIPTION: Pressure Transmitter EQUIP MARK NO (S):
PT-LM-100A,B,C, and D MANUFACTURER:
Fischer and Porter MODEL NUMBER (S):
50EN107BCXB 2.0 BRIEF OVERVIEW OF STATUS Previous review of the qualification status of these transmitters has resulted in a lack of documentation being made available.
As a result, these transmitters are scheduled to be replaced within the time frame allotted by the NRC Rulemaking.
3.0 REVIEWS
SUMMARY
()
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Not Qualified, l-DEFICIENCIES / CONCERNS:
Qualification documentation not available, i
Commercial grade units.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Qualified; Replace Device.
DEFICIENCIES / CONCERNS:
The device is not qualified for the specified integrated radiation dose.
C.
FRC/NRC QUALIFICATIONS STATUS:
(1.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Qualification documentation not available.
D.
DLC REVIEW
/s QUALIFICATIONS STATUS:
(I,b) Equipment Qualification Pending
-()
Modification.
DEFICIENCIES / CONCERNS:
The existing equipment's qualification documentation for radiation, temperature and pressure as well as aging evaluation requirement has not been obtained.
l 4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED j
III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 INITIAL DLC REVIEW DOCUMENTS i
i 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981)
O i V 2.
SCEW SHEETS (Reference 79-01B DLC Submittel, October 15, 1981) l -.
f 6.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981, Submittal) l 7.0 DLC ACTION PLAN i
DLC is actively. pursuing the appropriate qualification documentation for the replacement Barton Transmitters, which have been received at the Beaver Valley Power Station but not installed pending the receipt and review of qualification l
1 (ocumentation from the supplier.
It is anticipated that they will be installed within the time frame allotted by the NRC Rulemaking.
1 O
t e
v*w o-
- - =
+w n--
DLC TAB f 41 FRC TAB # U
- 4 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 41 FRC NUMBER (S):
42 EQUIP DESCRIPTION: Pressure Transmitter EQUIP MARK NO (S): PT-RS-156A & B MANUFACTURER:
Fischer and Porter MODEL NUMBER (S):
50EP1071BCXB 2.0 BRIEF OVERVIEW OF STATUS Previous review of the qualification status of these transmitters has resulted in a lack of documentation being made available.
As a result, these transmitters are scheduled to be replaced within the time frame allotted by the NRC Rulemaking.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
Qualification documentation not available.
i Commercial grade units.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Qualified; Replace Device.
DEFICIENCIES / CONCERNS:
The device is not qualified for the specified integrated radiation dose.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
I' l
DEFICIENCIES / CONCERNS:
Qualification documentation not available.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
The existing equipment's qualification I
documentation for radiation, temperature and pressure as well as aging evaluation requirement has not been obtained.
4.0 NRC/FRC QUALIFICATION CATECORY 1
FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT 4
QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
".HEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) i 6.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981, Submittal) 7.0 DLC ACTION PLAN l
DLC is actively pursuing the appropriate qualification documentation for the replacement Barton Transmitters, which have been received at the Beaver Valley Power Station but not installed within the time frame allotted by the NRC Rulemaking.
O
..-,.,n.,.~
-s--
DLC TAB # 42 FRC TAB f E
~
O DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 42 FRC NUMBER (S):
44 EQUIP DESCRIPTION: Pressure Transmitter EQUIP MARK NO (S): PT-MS-474,475,476,484,485,486,494,495 and 496 MANUFACTURER:
Fischer & Porter MODEL NUMBER (S):
50EP1041 4
2.0 BRIEF OVERVIEW OF STATUS Previous review of the qualification status of these transmitters has resulted in a lack of documentation being made available.
As a result, these transmitters are scheduled to be replaced within the time frame allotted by the NRC Rulemaking.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Not Qualified.
DEFICIENCIES / CONCERNS:
Qualification documentation not available.
-Commercial grade units.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Qualified. Replace Device.
DEFICIENCIES / CONCERNS:
The device is not qualified for the specified integrated radiation dose.
C.
FRC/NRC QUALIFICATIONS STATUS:
(I b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Qualification documentation not available.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(I.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
The existing equipment's qualification documentation for radiation, temperature and pressure as well as aging evaluation requirement has not been obtained.
L i.
f 4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED 1.b EQUIPMENT QUALIFICATION PENDING MODIFICATION X
X II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT i
QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION l
III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 INITIAL DLC REVIEW DOCUMENTS i
1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) l
'6. 0 OTHER REFERENCE DLC DOCUMENTS i
1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 79-01B, October 15, 1981, Submittal) f 7.0 DLC ACTION PLAN DLC is actively pursuing the appropriate qualification documentation for the replacement Barton Transmitters, which have been received at the Beaver Valley Power Station but not installed pending the receipt and review of qualification documentation from the supplier.
It is anticipated that they will be installed within the time frame alloted by the NRC Rulemaking.
i alO F.
DLC TAB # 43, FRC TAB # 16 J
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION f
REVIEW OF ELECTRICAL EQUIPMENT i
1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 43 FRC NUMBER (S):
16 l
EQUIP DESCRIPTION: Motorized Valve Actuator EQUIP MARK NO (S): MOV-FW-156A MANUFACTURER:
MODEL NUMBER (S):
SMB-00 I
t i O
)
NO ADDITIONAL REVIEW WAS CONDUCTED I
BECAUSE EQUIPMENT EXEMPT FROM QUALIFICATION I
i
_ _ _ _ m.
i 2.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED 4
I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION i
j o
i II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED b
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT j
QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED l
l l
III.a EQUIPMENT EXEMPT FROM QUALIFICATION X
i III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW
)
i
(
IV.
DOCUMENTATION NOT MADE AVAILABLE l
l I
Lo l
i a
r 1
l
- O i
(
.~--,e..
w,.-,
m-
--.v.4,_---em.<,,,.
l 1
DLC TAB # M
- p FRC TAB i E DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-OlB TAB NUMBER: 43 l
FRC NUMBER (S):
17 l
i.
EQUIP DESCRIPTION: - Motorized Valve Actuator EQUIP MARK NO (S):
MOV-RS-155A,B.- 156A,B MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-00 l
J O
NO ADDITIONAL REVIEW WAS COND"CTED i
BECAUSE-EQUIPMENT EXEMPT FROM QUALIFICATION I
1 O
--m-,--r--,-
-r-m--
v-n-sg
,e_n- - -.,, - -,
, -,, ~ - -
,,-e-
,----m,---
a
= ~
e 2.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION X
III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION
-REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 4
1
)
i a
i l
=%
O f
DLC TAB f 43, FRC TAB i 18_
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 43 FRC NUMBER (S):
18 EQUIP DESCRIPTION: Motorized Valve Actuator EQUIP MARK NO (S): MOV-RW-103A,B,C,D - 106A,B MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-00 4 O NO ADDITIONAL REVIEW WAS CONDUCTED i
BECAUSE f
EQUIPMENT NOT IN THE SCOPE OF PRESENT REVIEW i
l O
t 2.0 NRC/FRC QUALIFICATION CATECORY FRC DLC I.a EQUIPMENT QUALIFIED 1.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT. QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION X
REVIEW p
IV.
DOCUMENTATION NOT MADE AVAILABLE O
E i
O
DLC TAB # M FRC TAB # H DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT.
1.0 EQUIPMENT QUALIFICATION SUMHARY 79-01B TAB NUMBER: 43 FRC NUMBER (S):
19 EQUIP DESCRIPTION: Motorized Valve Actuator EQUIP MARK NO (S): MOV-RW-104A MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-00 j
I
?
NO ADDITIONAL REVIEW WAS CONDUCTED i
BECAUSE EQUIPMENT NOT IN THE SCOPE OF PRESENT REVIEW
- O I
2.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III,b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION X
REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE l
l f
l i
O
DLC TAB f 43 FRC TAB f 20,86 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 43 FRC NUMBER (S):
-20 EQUIP DESCRIPTION: Motor Operators EQUIP MARK NO (S):
MOV-FW-151A,B*,C,D E,F MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-00
- MOV-FW-151B was incorrectly addressed in the FRC TER twice, Tabs #20 and #86, i
DLC believes that TAB #86 is not applicable.
2.0 BRIEF OVERVIEW OF STATUS The Limitorque actuators are located in the auxiliary feed pump room and are not required to operate while subject to harsh environments.
Thus, they are
()
considered exempt from the requirements of qualification for harsh environments.
I 3.0 REVIEWS
SUMMARY
)
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified - Exempt from Qualification.
DEFICIENCIES / CONCERNS:
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Reviewed.
DEFICIENCIES / CONCERNS:
C.
FRC/NRC QUALIFICATIONS STATUS:
(II.c) Equipment Satisfies all Requirements Except Qualified Life or Replacement Schedule.
DEFICIENCIES / CONCERNS:
Inadequate aging degradation and qualified life.
O a
D.
DLC REVIEW
()
QUALIFICATIONS STATUS:
(III.b) Equipment not in the scope of the qualification review.
DEFICIENCIES / CONCERNS:
This equipment item should not have been reviewed by the NRC, because it is considered exempt from qualification.
4.0 NRC/FRC QUALIFICATION CATEGORY 4
FRC DLC i
2 l
I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION l
II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED 1
~
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT X
QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED l
-III.a EQUIPMENT EXEMPT FROM QUALIFICATION
-X III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION O
REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
As discussed in the original 79-01B submittals to.the NRC, DLC considers these f'
particular valves to be exempt from qualification requirements.
I l
l-5.0 INITIAL DLC REVIEW DOCUMENTS ll 1.
SUMMARY
SHEETS (79-01B DLC Submittal) - October 15, 1981 2.
SCEW SHEETS (79-01B DLC Submittal) - October 15, 1981 P
- O 9
e
-. + +
-v~
--s,-
~,
,,.n.
ns
-a we e,,,-
+n
I DLC TAB # 43 FRC TAB f 21 DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-OlB TAB NUMBER: 43 FRC NUMBER (S):
21 EQUIP DESCRIPTION: Motorized Valve Actuator EQUIP MARK NO (S): MOV-RW-104B,C.D. - 105A.B C.D MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-000
' O P
NO ADDITIONAL REVIEW WAS CONDUCTED BECAUSE l
EQUIPMENT NOT IN THE SCOPE OF PRESENT REVIEW :
i O
p.
-w-<+
b
+
=<a 4
.._.-A, p p a
A 2.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT j
QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION X
REVIEW
~
IV.
DOCUMENTATION NOT MADE AVAILABLE r
'O 1
DLC TAB # M FRC TAB # 82 1
DLC RESPONSE TO 1982 FRC/NRC EN'IRONMENTAL QUALIFICATION V
REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 43 i
FRC NUMBER (S):
82 EQUIP DESCRIPTION: Motorized Valve Actuator EQUIP MARK NO (S): MOV-FW-156B,C MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-00 l
O 1
NO ADDITIONAL REVIEW WAS CONDUCTED i
BECAUSE EQUIPMENT EXEMPT FROM QUALIFICATION l'
I l
l
- ~ -
h 2.0 NRC/FRC QUALIFICATION CATEGORY 4
FRC DLC I.a EQUIPMENT QUALIFIED.
i I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE' JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION X
III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE e
4 i
l lO i
i 0
I l'
l' l
I "OL i
i
\\~
s
DLC TAB # 43, FRC TAB # 85 O
v DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-OlB TAB NUMBER: 43 FRC NUMBER (S):
85 EQUIP DESCRIPTION: Motorized Valve Actuator EQUIP MARK NO (S): MOV-MS-105 MANUFACTURER:
Limitorque 1.
MODEL NUMBER (S):
SMB-000 O
NO ADDITIONAL REVIEW WAS CONDUCTED i
BECAUSE EQUIPMENT NOT IN THE SCOPE OF PRESENT REVIEW r
1 O
t
-e
, wee, w
.---,,--,n..
,,--w-r
i 2.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION X
REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE O
1 s
l DLC TAB # M j
FRC TAB f E DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 43 FRC NUMBER (S):
87 EQUIP DESCRIPTION: Motorized Valve Actuator EQUIP MARK NO (S): MOV-RW-114A,B MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-00 O
NO ADDITIONAL REVIEW WAS CONDUCTED i
BECAUSE l
EQUIPMENT NOT IN THE SCOPE OF PRESENT REVIEW O
N 1
2.0 NRC/FRC QUALIFICATION CATEGORY f
FRC DLC l
I a-EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFIC IION NOT ESTABLISHED j
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED I
III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION X
REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE l
l t
O a
~
l 1
A
-t N
oo i
l 1
s DLC TAB f 44 FRC TAB # 22.23,88 O
DLC RESPONSE TO l',82 FRC/NRC ENVIRONMENTAL QUALIFICATION 9
REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 44 FRC NUMBER (S):
22, 23, 88 EQUIP DESCRIPTION: Motor Operators EQUIP MARK NO (S): MOV-SI-863A,B, - 864A B. - 885A,B.C.D. - 890A,B C i
MANUFACTURER:
Limitorque MODEL NUMBER (S)'.
- SMB-00, SMB-2T s
1
(
2.0 l)RIEF OVERVIEW OF STATUS TheselMOV's are located in the safeguard area of the plant and are qualified for the harsh environment to wY y could potentially be exposed.
(130*F, 100%
R.H.
and 0.7 Mrad).
Duq
,lght Company has conducted a thermal aging analysis of the Limitorque egradable materials and. has found that the j
materials, except for the lubricant and buna-seal, are expected to have a qualified life Sreater than forty years.
The replacement cycle assessment for the lubricant and buna-seal are currently being conducted by Duquesne Light Company.
s 3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL i
QUALIFICATIONS STATUS:
Qualified.
I DEFICIENCIES / CONCERNS:
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Reviewed.
DEFICIEY.CIES/ CONCERNS:
- 8. -
, 3, Ci FRC/NRC I
r l
QUALIFICATIONS STATUS:
- (II.c) Satisfies all requirements except
.g l
I qualified life.
L'$
l'4 DEFICIENCIES / CONCERNS:
Inadequate aging degradation evaluation and qualified life.
i n
.{
D.
li DLC REVIEW QUALIFICATIONS STATUS:
III.c) Satisfies all requirements except
['
qualified life.
h j
3 DEFICIENCIES / CONCERNS:
Aging kvaluation and qualified life.
l l
(
k k
..)
4-_
7.g s
j 2
..,a s
l j
,_,,w
~ ** L
- f*
'Y
, 4.0 NRC/FRC QUALIFICATION _CATEGOhtY 1,
-,n.
I
_ ~, < ?. l
/,.
FN DLC.
s y
-e -
r I.a EQUIPMENT QUALIFIED
,s J' $
I;b EQUIPMENT QUALIFICATIs'i' PENDING MODII'ICATION II.a
'tQUIPd".NTQUALIFICATIONN01]gIABLISHED g'
~
-~
- +':
~
II.b '
EQUIPMENT NOT QUALIFIG_
e v
s
- x,+-
r
_X X
y ';
['
II.c f4QUIPWMT SATISVIFS AbL~ REQUIREMENTS M CEPT
QUALIFIED LIFEJOB ' REPLACEMENT SCNEDULE 94STIFIFD'
~
III.a EQUIFitENT, EXEMPT FRON QUALIFICATION f f.
~
EQUIIMENT NOT INiTHR SCOPE OF TUE QUALIFICATION-III.b '
REVIEW
~
~ '
E
/
e N
J c
c,.
s f
~
.i IV.
DOCUMENTATION NOT MAliE: AVAN dBLE
, " ~
p-
-s j
.(
n;.
)
5.0 REVIEW OF NRC/FRC DEFICIENCIE 6 '
?.,
A.
DEFICIENCY CONCERN: Qualified I.ife/ Replacement Schedule.
s DISCUSSICN/ PROPOSED ACTION:
Qualdfiedlifeofidentiffed-degradable l
materials is greater than 40 years."
Additional efforts to confuct, aging analysis will be performed, at which time an independent assessment qualified life will be completed.
i B.
DEFICIENCY CONCERN: Inadequate Aging Degradat on EvalEation.
j DISCUSSION / PROPOSED ACTION:
According to the manufacturer, quaiified life of identified degradable materials i
- is greater than 40 years. A preliminary l
independent aging assessment agrees with this 40 year life except for the lubricant which must be replaced periodically.
6.0 INITIAL DLC REVIEW DOCUMENTS 1..
SUMMARY
SLEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 7.0 DLC ACTION PLAN Duquesne Light Company is continuing its efforts to identify additional degradable materials of construction.
lp a s DLC~ TAB # 45 FRC TAB f 16.12,15 O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT j
L-1.0 EQUIPMENT QUALIFICATION
SUMMARY
~
t 79-01B TAB NUMBER: 45 FRC NUMBER (S):
10,12,15 EQUIP DESCRIPTION: Motor Operator
~
EQUIP MARK NO (S): MOV-CH-289, 381, MOV-SI-836, 367C & D.
MOV-SI-869A & B MOV-SI-860A & B. MOV-SI-862A & B MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-00 i
I 2.0 BRIEF OVERVIEW OF STATUS A DLC review of the 79-01B Submittal documents and the NRC/FRC SER has established the status for this equipment as "II.a Qualification Not Established." Similarity between the tested and installed models is currently being established.
In addition, an independent aging analysis re-evaluation needs to be conducted to establish the qualified life and replacement schedule.
. O
~
l 3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Qualified.
r I
i B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Revieacd.
C.
FRC/NRC l
QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established.
DEFICIENCIES / CONCERNS:
Similarity, aging degradation, qualified life or replacement schedule.
D.
DLC REVIEW QUALIFICATIONS STATUS:
(II a) Equipment Qualification not Established.
.: O DEFICIENCIES / CONCERNS:
Similarity, aging degradation, qualified life or replacernent schedule.
--.. ~... - -. -.. -. -
4.0 NRC/FRC QUALIFICATION CATECORY FRC DLC I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED X
X II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCNEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Inadequate similarity between installed equipment i
and test specimen.
DISCUSSION / PROPOSED ACTION:
Deficiency has not been removed yet.
l Traceability documents are in the process of being obtained from the manufacturer.
i B.
DEFICIENCY CONCERN: Aging degradation evaluated inadequately.
i l
DISCUSSION / PROPOSED ACTION:
Independent aging analysis will bc conducted after receiving additional l
material information from the manufacturer.
C.
DEFICIENCY CONCERN: Qualified life or replacement schedule not established.
l DISCUSSION / PROPOSED ACTION:
Independent aging analysis will be conducted after receiving material information from the manufacturer.
The qualified life or replacement schedule vill be established based on this analysis.
O
~
l
+
6.0 INITIAL DLC REVIEW DOCUMENTS
()
1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 1 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 30-Day 1983 l
Response) l l
I 8.0 DLC ACTION PLAN l
DLC is attempting to obtain traceability documents to demonstrate which applicable test reports are pertinent to the equipment.
In addition, details of the construction of the motor brake assembly are being obtained.
l
(
O i
l O
i DLC TAB f 45 i
l FRC TAB # 11,13,14,89 O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT l
1.0 EQUIFMENT QUALIFICATION
SUMMARY
1 79-015 TAB NUMBER: 45 i
FRC NUMBER (S):
11.13.14,89 i
l EQUIP DESCRIPTION: Motor Operator EQUIP MARK NO (S): MOV-CH-373, 370, MOV-CH-115B.C.D.E i
MOV-SI-867A B. MOV-CH-275A.B.C MANUFACTURER:
Limitorque MODEL NUMBER (S):
SMB-00
~
2.0 BRIEF OVERVIEW OF STATUS The qualification is based on type testing by similarity.
An independent aging
[
analysis is being conducted to evaluate any aging degradation and to determine qualified life and the replacement schedule.
Identification of actuators' motor brake assembly is being conducted.
I 3.0 REVIEWS
SUMMARY
l A.
INITIAL DLC SUBMITTAL l
QUALIFICATIONS STATUS:
Qualified.
I DEFICIENCIES / CONCERNS:
None.
B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Reviewed.
C.
FRC/NRC QUALIFICATIONS STATUS:
(II.c) Equipment satisfies all requirements except Qualified Life or Replacement Schedule Justified.
DEFICIENCIES / CONCERNS:
Aging degradation, qualified life or i
replacement schedule.
i D.
DLC REVIEW QUALIFICATIONS STATUS:
(II.c) Equipment satisfies all requirements except Qualified
-Life or Replacement-Schedule.
[
DEFICIENCIES / CONCERNS:
Aging degradation, qualified life or replacement schedule.
4.0 NRC/FRC QUALIFICATION CATECORY-FRC DLC I.a EQUIPMENT QUALIFIED I.h EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED l
II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT X
X QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW j
IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Aging Degradation Evaluated Inadequately.
DISCUSSION / PROPOSED ACTION:
An independent aging analysis.is being O
conducted.
It is pending additional material information from the manufacturer, i
B.
DEFICIENCY CONCERN: Qualified Life or Replacement Schedule not Established.
I DISCUSSION / PROPOSED ACTION:
Aging analysis is being conducted. The qualified life and replacement schedule will be established based on this analysis.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) l 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION-(Reference 30-Day 1983 Response)
O 8.0 DLC ACTION PLAN DLC is currently performing an independent aging evaluation on the equipment and contacting the manufacturer for motor brake assembly details.
DLC TAB # 46 FRC TAB f y DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1,0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 46 FRC NUMBER (S):
61 EQUIP DESCRIPTION: Outside Recire. Spray Motor EQUIP MARK NO (S):
RS-P-2A, 2B MANUFACTURER:
Louis Allis MODEL NUMBER (S):
1-279480-001 2.0 BRIEF OVERVIEW OF STATUS These motors are used for the outside recirculation spray pumps RS-P-2A, 2B.
g it was determined that no documentation exists for In previous reviews by DLC, the pump motor qualification and the decision was made by DLC to replace them.
these motors were replaced during the Second Refueling Outage with As a result, located qualified Siemen-Allis Motors and their qualification documentation is in the DLC EQ File 2009.
V 3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL QUALIFICATIONS STATUS:
Documentation Incomplete.
DEFICIENCIES / CONCERNS:
No Documentation for Post-LOCA Radiation Motors scheduled to be replaced.
Dose.
]*
B.
EDS REVIEW QUALIFICATIONS STATUS:
Documentation Incomplete.
f DEFICIENCIES / CONCERNS:
No Qualification Documents Exists. Perform Analysis to Establish Qualification.
C.
FRC/NRC j
l QUALIFICATIONS STATUS:
(1.b) Equipment Qualification Pending Modification.
DEFICIENCIES / CONCERNS:
Inadequate Documentation.
]
D.
DLC REVIEW l,
QUALIFICATIONS STATUS:
(I.a) Equipment Qualified.
i
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC
)
See 5.0(A)
I.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.h EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Inadequate Qualification Documentation.
DISCUSSION / PROPOSED ACTION:.
These motors were replaced with Siemens-Allis Motors during the Second Refueling Outage. The documentation for
}
this replacement is located in the DLC Equipment File #2009.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal) - VOIDED 2.
SCEW SHEETS (Reference 79-01B DLC Submittal) - VOIDED
l DLC TAB i 46 FRC TAB # ICI O
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 46 FRC NUMBER (S):
62 EQUIP DESCRIPTION: Auxiliary Feedwater Pump Motor EQUIP MARK NO (S):
FW-P-3A, 3B MANUFACTURER:
Louis-Allis MODEL NUMBER (S):
269319-001 2.0 BRIEF OVERVIEW OF STATUS This motor, located outside containment and subjected to radiation as its only harsh service condition, has been qualified by analysis and the aging evaluation has been completed.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL O
QUALIFICATIONS STATUS:
Documentation Incomplete.
l DEFICIENCIES / CONCERNS:
No documentation for Post-LOCA radiation dose.
Perform additional analysis or replace.
i B.
EDS REVIEW f
QUALIFICATIONS STATUS:
Documentation Incomplete, l
DEFICIENCIES / CONCERNS:
No Qualification Documentation Exists.
l l
C.
FRC/NRC QUALIFICATIONS STATUS:
(II.a) Equipment Qualification Not Established.
i D.
DLC REVIEW r
QUALIFICATIONS STATUS:
(I.a) Equipment Qualified.
O
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC I.a FQUIPMENT QUALIFIED X
I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED X
II.b EQUIPMENT NOT QUALIFIED l
II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT QUALIFIED LIFE OR REPLACEMENT SCNEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
The motor has now been determined by DLC to be qualified, because of recent analysis conducted. The analysis is located in the DLC EQ File - IV.B.1/46.
(
5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY. CONCERN: Inadequate Documentation.
DISCUSSION / PROPOSED ACTION:
Additional analysis has been performed.
I 6.0. INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Submittal, October 15, 1981).
2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981).
t i
O
DLC TAB i 47 FRC TAB # lli s
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 47 FRC NUMBER (S):
63 EQUIP DESCRIPTION: Electric Motor EQUIP MARK NO (S):
SI-P-1A, B MANUFACTURER:
Westinghouse Electric Company MODEL NUMBER (S):
FR509P20 2.0 BRIEF OVERVIEW OF STATUS Duquesne Light Company has reviewed this motor and has determined through previous testing and supplemental analysis that it is qualified for its accident mitigating function. The motor is located outside the containment. WCAP 8754, Rev.
1, demonstrates from radiation and thermal aging testing of insulation coupon specimens, that the thermoelastic insulation system will operate satisfactorily and continuously for a minimum of 5.0 years at a maximum temperature of 130*F and with a radiation exposure of 6.5 Mrads total integrated O
dose.
3.0 REVIEWS
SUMMARY
A.
INITIAL DLC SUBMITTAL i
QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
Motorettes of insulation only were tested.
3 B.
EDS REVIEW QUALIFICATIONS STATUS:
Not Reviewed.
C.
FRC/NRC REVIEW QUALIFICATIONS STATUS:
(II.a) Qualification Not Established.
DEFICIENCIES / CONCERNS:
Inadequate qualification documentation, inadequate aging degradation evaluation, qualified
- life, inadequate duration of temperature / pressure exposure.
D.
DLC REVIEW
/T QUALIFICATIONS STATUS:
(II.c) Equipment satisfies all the
\\/
requirements except Qualified Life and Replacement Schedule.
DEFICIENCIES / CONCERNS:
Qualified life of parts and their replacement frequency are currently being evaluated.
4.0 NRC/FRC QUALIFICATION CATEGORY FRC DLC 1.a EQUIPMENT QUALIFIED I.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED X
II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT X
QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION j
REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
The difference in qualification category is due to the following reasons:
Motor splice information was not available previously for the NRC/FRC a.
i review.
y b.
The motor splices were changed during the Second Refueling Outage.
i 5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Evidence of qualification of motor to lead splice materials.
DISCUSSION / PROPOSED ACTION:
The existing motor splices were replaced during the Second Refueling Outage with qualified Kerite #DS7018.
The Duquesne Light Company EQ File #2025 contains qualification documentation.
B.
DEFICIENCY CONCERN: Evidence of qualification for lubricant-bearing-seal system.
DISCUSSION / PROPOSED ACTION:
Type of bearings and lubricants are being investigated and estimated life will be evaluated according to IEEE Standard 334-1974.
()
C.
DEFICIENCY CONCERN: Inadequate aging degradation evaluation.
DISCUSSION / PROPOSED ACTION:
The aging evaluation is currently being performed.
l 6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SHEETS (Reference 79-01B DLC Oct. 15, 1981 Submittal) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal Oct. 15, 1981) 7.0 OTHER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 30-Day 1983 Response) 8.0 DLC ACTION PLAN Duquesne Light Company is currently evaluating the motor's constituent parts for thermal, radiation and wear aging.
As soon as this is done, the motor's qualified life and replacement cycle will be determined.
O a
i
?
t 4
0
l DLC TAB i 48 FRC TAB i E p
DLC RESPONSE TO 1982 FRC/NRC ENVIRONMENTAL QUALIFICATION REVIEW OF ELECTRICAL EQUIPMENT 4
1.0 EQUIPMENT QUALIFICATION
SUMMARY
79-01B TAB NUMBER: 48 FRC NUMBER (S):
64 EQUIP DESCRIPTION: Electric Motor EQUIP MARK NO (S): CH-P-1A B.C MANUFACTURER:
Westinghouse Electric Company MODEL NUMBER (S):
FR-58089 2.0 BRIEF OVERVIEW OF STATUS Light Company has reviewed this motor and has determined through Duquesne previous testing and supplemental analysis that it is qualified for its accident i
mitigating function. The motor is located outside the containment. WCAP'8754 Rev.
1, demonstrates from radiation and thermal aging testing of insulation coupon specimens, that the thermoelastic insulation system will operate f
satisfactorly for a minimum of 5.0 years at a maximum temperature of 130*F and with a radiation exposure of 6.5 Mrads total integrated dose.
e 3.0 REVIEWS
SUMMARY
)
A.
INITIAL DLC SUBMITTAL i
QUALIFICATIONS STATUS:
Qualified.
DEFICIENCIES / CONCERNS:
Motorettes of insulation only were tested.
B.
EDS REVIEW I
QUALIFICATIONS STATUS:
Not Reviewed.
C.
FRC/NRC REVIEW j
QUALIFICATIONS STATUS:
(II.a) Qualification Not Established.
DEFICIENCIES / CONCERNS:
Inadequate qualification documentation, inadequate aging degradation evaluation, qualified
- life, inadequate duration of temperature / pressure exposure.
D.
DLC REVIEW QUALIFICATIONS STATUS:-
(II.c) Equipment Satisfies All the Requirements Except Qualified Life and O-Replacement Schedule.
DEFICIENCIES / CONCERNS:
Qualified life of parts and their replacement frequency are currently being evaluated.
~
~
.. =_
4.0 NRC/FRC QUALIFICATION CATECORY t
FRC DLC I.a EQUIPMENT QUALIFIED 1.b EQUIPMENT QUALIFICATION PENDING MODIFICATION II.a EQUIPMENT QUALIFICATION NOT ESTABLISHED X
j II.b EQUIPMENT NOT QUALIFIED II.c EQUIPMENT SATISFIES ALL REQUIREMENTS EXCEPT X
QUALIFIED LIFE OR REPLACEMENT SCHEDULE JUSTIFIED III.a EQUIPMENT EXEMPT FROM QUALIFICATION III.b EQUIPMENT NOT IN THE SCOPE OF THE QUALIFICATION REVIEW IV.
DOCUMENTATION NOT MADE AVAILABLE EXPLANATION OF DIFFERENCES IN QUALIFICATION CATEGORY:
i The difference in qualification category is'due to the following reasons:
Some information was not available previously for the NRC/FRC review.
a.
b.
The motor splices were changed during the Second Refueling Outage.
5.0 REVIEW OF NRC/FRC DEFICIENCIES A.
DEFICIENCY CONCERN: Evidence of qualification of motor to lead splice materials.
DISCUSSION / PROPOSED ACTION:
The existing motor splices were replaced during the Second Refueling Outage with qualified Kerite #DS7018.
The Duquesne Light Company EQ File #2025 contains qualification documentation.
B.
DEFICIENCY CONCERN: Evidence of qualification for lubricant-bearing-seal system.
I DISCUSSION / PROPOSED ACTION:
Type of bearings and lubricants are being investigated and estimated life will be evaluated according to IEEE Standard 334-1974.
I C.
DEFICIENCY CONCERN: Inadequate aging degradation evaluation.
DISCUSSION / PROPOSED ACTION:
The aging evaluation is currently being performed.
6.0 INITIAL DLC REVIEW DOCUMENTS 1.
SUMMARY
SilEETS (Reference 79-OlB DLC Submittal, October 15, 1981) 2.
SCEW SHEETS (Reference 79-01B DLC Submittal, October 15, 1981) 7.0 OTilER REFERENCE DLC DOCUMENTS 1.
JUSTIFICATION FOR CONTINUED OPERATION - (Reference 30-Day 1983 Response October 15, 1983) 8.0 DLC ACTION PLAN Duquesne Light Company is currently evaluating the motors constituent parts for the rmal, radiation and wear aging.
As soon as this is done, the motor's qualified life and replacement cycle will be determined.
/
\\_ /
?
i
's V