Forwards Revised Environ Qualification Master List, Originally Submitted by 830520 Response to 10CFR50,Paragraph 50.49(g) Re Environ Qualification of safety-related Electrical Equipment
ML20072J820
Person / Time
Site: North Anna  
Issue date: 06/22/1983
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: Clark R, Harold Denton
Office of Nuclear Reactor Regulation
References
110E, NUDOCS 8306300240
Download: ML20072J820 (3)


Text

'

VIROINIA ELECTRIC AND PowEn COMPANY Ricnwoxn,VIItGINIA 20261 W. L. STEWART June 22, 1983 NU EAa O a T w.

Mr. Harold R. Denton, Director Serial No.

110E Office of Nuclear Reactor Regulation PSC/ JEW:ses:

0545C Attention: Mr. Robert A. Clark, Chief Docket Nos.:

50-338 Operating Reactors Branch No. 3 50-339 Division of Licensing License Nos.:

NPF-4 U. S. Nuclear Regulatory Commission NPF-7 Washington, DC 20555 Gentlemen:

ENVIRONMENTAL CUALIFICATION OF SAFETY-RELATED ELECTRICAL EQUIPMENT NORTH ANNA POWER STATION UNIT NOS.1 AND 2 Our letter of May 20, 1983, Serial Number 110D, provided our response to 10 CFR Part 50, paragraph 50.49(g). Subsequent to the issuance of our response, events have occurred at North Anna Power Station which require that modifications to the response be effected.

During start up of North Anna Power Station Unit No. 2 after refueling, tha failure of an inordinate percentage of Weed Instrument Company Resistance Temperature Detectors (RTD's) required that they be replaced with Rosemount RTD's. The circumstances of these events were documented in our letters of May 27,1983 (Serial Numbers 257A and 331).

Since the Rosemount RTD's have only a limited qualification, a change to the Environmental Qualification Master List from that submitted on May 20, 1983 is required. Enclosure 1 provides the revised Master List pages which reflects the required replacement of these RTD's. The present schedule for upgrade of the RTD's is as stated in the May 20, 1983 response.

Yours very truly,

[

W. L. Stewart Enclosure cc: Mr. James P. O'Reilly, w/ attachment Regional Administrator Region II 101 Marietta Street, Suite 2900 kk Atlanta, Georgia 30303 Mr. M. B. Shymlock, w/ attachment NRC Resident Inspector North Anna Power Station 00306300240 830622 PDR ADDCK 05000338 P

PDR

. av.

l DATE t/09/03 VIRGINIA ELECTRIC Ate POWER COMPANY PAGE 13 l

EQUIPMENT QUALIFICATION MASTER LIST HORTH AtNA POWER STATION UNIT 2 NARK NUMBER SORT i

S T

A T D NARK HO.

DESCRIPTION MANUFACTURER NODEL NO.

SYS U 0 S C l

= = - - _ _ _ _

__=--____ ______

=. =---_ _ _ ______ _ _... _

TE-2317 RVLIS TEMP NINCO S8809 RC Q G s-TE-2318 RVLIS TEMP NIHC0 S8809 RC Q G TE-2319 RVLIS TENP HINCO S8809 RC Q G TE-2323 RVLIS TEMP HItCO S8809 RC Q G TE-2324 RVLIS TEMP NIHC0 S8809 RC Q G h.

l TE-2325 RVLIS TEMP NIHCQ

$8809 RC Q G l

TE-2326 RVLIS TEMP NIHC0

$8809 RC Q G

e..

l TE-2327 RVLIS TEMP HINCO S8809 RC Q G TE-2328 RVLIS TEMP NIHC0 58809 RC Q G 4.

TE-2329 RVLIS TEMP HINCO S8809 RC Q G TE-2410 RTD,RCS WIDE RANGE WEED **SP612D-28-C6 F-13.5-0-0 RC Q B s

TE-2411B RTD, RCS NARROW RANGE ROSEHOUNT 176KF RC R E TE-2411C RTD, RCS HARROW RANGE ROSENOUNT 176KF RC R E o

TE-2411D RTD, RCS HARROW RANGE ROSEHOUNT 176KF RC R E TE-2412B RTD, RCS HARROW RANGE ROSEHOUNT 176KF RC R E by

~

TE-2412C RTD, RCS NARROW RANGE ROSENOUNT 176KF RC R E TE-2412D RTD, RCS liARROW RANGE ROSENOUNT 176KF RC R E TE-2413 RTD.RCS WIDE RANGE NEED mmSP612D-2B-C6 F-13.5-0-0 RC Q B TE-2420 RTD,RCS WIDE RANGE WEED mmSP6120-28-C6 F-13.5-0-0 RC Q B TE-2421B RTD, RCS HARROW RANGE ROSEHOUNT 176KF RC R E TE-2421C RTD, RCS HARROW RANGE ROSENCUNT 176KF RC R E TE-2421D RTD, RCS HARROW RANGE ROSEN0UNT 176KF RC R E

(.

a a

DATE 6/07/C3 VIRGINIA ELECTRIC AND POWER COMPANY PAGE 19 NORTH AtilA POWER STATION UNIT 2 EQUIPMENT QUALIFICATION NASTER LIST MARK hut 1BER SORT S

T A

T D NARK NO.

DESCRIPTION MANUFACTURER N00EL NO.

SYS U 0 S C TE-2422B RTD, RCS NARROW RANGE ROSEN0UNT 176KF RC R E TE-2422C RTU, RCS NARROW RANGE ROSEMOUNT 176KF RC R E TE-24220 RTD, RCS NARROW RANGE ROSENOUNT 176KF RC R E i

TE-2423 RTD RCS WIDE RANGE WEED unSP612D-2B-C6 F-13.5-0-0 RC Q B TE-2430 RTD, RCS WIDE RANGE ROSEN0UNT 176KS RC R B TE-2431B RTD, RCS NARROW RANGE ROSE 10UNT 176KF RC R E TE-2431C RTD, RCS NARROW RANGE ROSENOUNT 176KF RC R E i

TZ-2431D RTD, RCS NARROW RANGE ROSENOUNT 176KF RC R E TE-2432B RTD, RCS NARROW RANGE ROSENOUNT 176KF RC R E i

TE-2432C RTD, RCS NARROW RANGE ROSEN0UNT 176KF RC R E TE-24320 RTD, RCS NARROW RANGE ROSEN0UNT 176KF RC R E TE-2433 RTD RCS WIDE RANGE WEED wmSP612D-2B-C6 F-13.5-0-0 RC Q B TN TERMINATIONS RAYCHEN HVT/HVNC N/A Q E TT TERNINATION TAPE OKONITE T-95/T-35 Q E TV-HC-200A SOV, HYDROGEN ANALYZER SYSTEN VALCOR V526529531 HC Q T TV-HC-2008 SOV, HYDROGEN ANALYZER SYSTEN VALCOR V526529531 HC Q T TV-HC-201A SOV. HYDROGEN ANALYZER SYSTEN VALCOR V526529531 HC Q T TV-HC-2010 SOV. HYDROGEN ANALYZER SYSTEN VALCOR V526529531 HC Q T TV-HC-202A SOV. HYDROGEN ANALYZER SYSTEM VALCOR V526529531 HC Q T TV-HC-2023 SOY, HYDROGEN ANALYZER SYSTEN VALCOR V526529531 HC Q T TV-HC-203A SOV, HYDROGEN ANALYZER SYSTEN VALCOR V526529531 HC Q T TV-HC-2038 SOV. HYDROGEN ANALYZER SYSTEN VALCOR V526529531 HC Q T b

5