- = ) C--
n m oon nxnon
)
- w om :
1671 Worcemer Eood M a h. M e"
- 01701 Put2c Service of New Hampshire (617) 872 8100 June 10, 1983 S BN-518 T.F. Q2.2.2 United States Nuclear Regulat ory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:
Mr. Richard W. Starostecki, Director Division of Resident and Project Inspection Re f ere nces :
(a) Construction Permit CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) Telecon of January 10, 1983, H. E. Wingate (YAEC) to Eugene Kelly (NRC Region I)
(c) PSNH Letter, dated February 11, 1983, " Interim 10CFR50.55(e) Report; Westinghouse EMD Cate Valve Position In lication," J. DeVincentis to R. W. Starostecki (d) PSNH Letter, dated May 9,1983, " Interim 10CFR50.55(e)
Report; Westinghouse EMD Cate Valve Position Indication,"
J. DeVincentis to R. W. Starostecki
Subject:
Final 10CFR50.55(e) Report; Westinghouse EMD Gate Valve Position Indication
Dear Sir:
In References (c) and (d), we filed interim 10CFR50.55(e) reports regarding the potential for certain Westinghouse manufactured gate valves to provide indication that they are closed prior to the valve disc, fully isolating flow.
The Westinghouse generic wiring specifications incorporate a motor operated valve limit stitch setting which may provide, under certain conditions, an erroneous indication that the valve is fully closed when, in actuality, it may be slightly open.
If the valve were to bind subsequent to receipt of a closure indication, an intersystem leakage path may go unrecognized.
Weetinghouse has provided r, recommended modification to the generic wiring specification via a Field Change Notice. This change provides a new procedure for setting and connecting the limit switch to ensure-that upon receipt of a closure indication the flow path has been essentially isolated.
8306280545 830610 PDR ADOCK 05000443 A
S PDR hI
~ OOO Elm St., P.O. Box 330. Monchester. NH O3105 + Telephone (603) 669-4000. TWX 7102207595 h
/h
J e.
e United States Nuclear Regulatory Commission June 10, 1983 Attention:
Mr. Richard W. Starostecki Page 2 4
PSNH has reviewed the proposed Westinghouse modification and will implement the necessary changes as applicable to Seabrook Station.
Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY J. DeVincentis Project Manager ALL/MH0/PJ/cs cc: Atomic Safety and Licensing Board Service List Director, Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C.