Monthly Operating Rept for Jul 1994 for Limerick Generating Station Units 1 & 2
ML20072D731
Person / Time
Site: Limerick  
Issue date: 07/31/1994
From: Kelley S, Muntz J
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9408190217
Download: ML20072D731 (11)


Text

-.

Umerick Osnarating Ststi n a.

my PECO ENERGY

"f;;r~*"

Sanatoga. PA 19464 0920 T.S.6.9.1.6 August 10, 1994 Docket Nos. 50-352 50-353 License Nos. NPF-39 NPF-85 U.

S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, DC 20555

Subject:

Limerick Generating Station Monthly Operating Report For Units 1 and 2 Enclosed are the monthly operating reports for Limerick Units 1 and 2 for the month of July, 1994 forwarded pursuant to Technical Specification 6.9.1.6.

Very truly yours, (J)uk-A mes A. Muntz Director - Site Engineering sjk Enclosures cc:

T. T. Martin, Administrator, Region I, USNRC (w/ enclosures)

N.

S. Perry, USNRC Senior Resident Inspector LGS (w/ enclosures)

D.

R. Helwig, Vice President, Limerick Generating Station 100C?J 1000'T1 I

f<' A j

9408190217 940731 PDR ADOCK 05000352

/'

I R

PDR

Docket No. 50-352 Attachment to Monthly Operating Report for July 1994 Limerick Generating Station Unit 1 July 1 through July 31, 1994 I.

Narrative Summary of Operatina Exneriences Unit 1 began the month of July at a nominal 100% of rated thermal power (RTP).

Power was reduced a number of times during the month of July as a result of high turbine backpressure.

On July 9, 1994, at 0020 hours2.314815e-4 days <br />0.00556 hours <br />3.306878e-5 weeks <br />7.61e-6 months <br /> power was reduced for condenser maintenance activities and to perform other testing activities.

Power was reduced to 75% RTP.

At 0104 hours0.0012 days <br />0.0289 hours <br />1.719577e-4 weeks <br />3.9572e-5 months <br /> on July 10, 1994, power was restored to 100% RTP.

On July 29, 1994, at 1342 hours0.0155 days <br />0.373 hours <br />0.00222 weeks <br />5.10631e-4 months <br /> the

'C' Reactor Feed Pump (RFP) tripped off.

This resulted in an automatic Reactor Recirculation Pump runback.

Power was stabilized at 80% RTP at 1348 hours0.0156 days <br />0.374 hours <br />0.00223 weeks <br />5.12914e-4 months <br />.

The cause of this event was that a housekeeping individual changing lights inadvertently hit the mechanical trip lever on the feedpump local panel.

The

'C' RFP was returned to service at 1520 hours0.0176 days <br />0.422 hours <br />0.00251 weeks <br />5.7836e-4 months <br /> and power was restored to 100% RTP at 1645.

Unit 1 ended this operating period at 100% of RTP.

II.

Challences to Main Steam Safety Relief Valves There were no challenges to the Main Steam Safety Relief Valves during the month of July.

i

AVEROGE DAILY UNIT PODER LEVEL DOCKET NO. 50 - 352

/

UNIT LIMERICK UNIT 1 DATE AUGUST 10.1994 COMPANY PECO ENERGY COMPANY STEVEN J.

KELLEY REPORTS ENGINEER SITE ENGINEERING LIMERICK GENERATING STATION

?ELEPHONE (610) 327-1200 EXTENSION 3763 MONTH JULY 1994 DAY AVERAGE DAILV POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWE-NET)

(MWE-NET) 1 1039 17 1041 2

1039 18 1038 3

1036 19 1035 4

~1037 20 1032 l

5 1037 21 1027 6

1012 22 1033 7

1026 23 1041 8

998 24 1026 9

780 25 1046 10 1056 26 1040 11 1049 27 1041 12 1042 28 1062 13 1037 29 999 14 1036 30 1039 l

15 1036 31 1041 16 1041

_______________-____-_-__a

. p.

OPERATING DATA REPORT DOCKET NO. 50 - 352 DATE AUGUST 10.1994 COMDLETED BY PECO ENERGV COMPANY STEVEN J.

KELLEY REPORTS ENGINEER SITE ENGINEERING LIMERICK GENERATING STATION TELEPHONE (610) 327-1200 EXTENSION 3763 OPERATING STATUS 1.

UNIT NAME: LIMERICK UNIT 1 NOTES: THERE WAS ONE LOAD DROPS 2.

REPORTING PERIOD:

JULV. 1994 GREATER THAN 20% DUE TO 3.

LICENSED THERMAL POWER (MWT):

3293 CONDENSER MAINTENANCE 4 NAMEPLATE RATING (GROSS WWE):

1138 ACTIVITY.

5. DESIGN ELECTRICAL RATING (w" MWE):

1055

6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWE):

2 7.

MAXIMUM DEPENDABLE CAPACITY (NET MWE):

1055 8.

IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7) SINCE LAST REPORT. GIVE REASONS:

9.

POWER LEVEL TO WHICH RESTRICTED. IF ANY (NET WWE):

10. REASONS FOR RESTRICTIONS. IF ANY:

THIS MONTH YR-TO-DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 744 5.087 74.471 l
12. NUMBER OF HOURS REACTOR WAS CRITICAL 744.0 4.236.2 60.435.3
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 14 HOURS GENERATOR ON-LINE 744.0 4.179.7 59.364.5
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 l
16. GROSS THERMAL ENERGY GENERATED (MWH) 2.426.587 12.976.589 182.427.348
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 791.100 4.220.290 59.262.330 l
18. NET ELECTRICAL ENERGY GENERATED (MWH) 764.188 4.068,185 56.854.175 l

l r

PAGE 1 OF 2

^

OPERATING DATA REPORT (CONTINUED)

DOCetET NO. 50 - 352 DATE AUGUST 10,1994 THIS MONTH VR_TO-DATE CUMULATIVE

19. UNIT SERVICE FACTOR 100.0 82.2 79.7
20. UNIT AVAILABILITY FACTOR 100.0 82.2 79.7

....______~_

21 UNIT CAPACITY FACTOR (USING MDC NET) 97.4 75.8 72.4

..-______~_.

22. UNIT CAPACITY FACTOR (USING DER NET) 97.4 75.8 72.4
23. UNIT FORCED OUTAGE RATE 0.0 1.3 4.5 24 SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):
25. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION):

FORECAST ACHIEVED INITIAL CRITICALITY 12/19/84 12/22/84 INITIAL ELECTRICITV MID APRIL 85 4/13/85 COMMERCIAL OPERATION 1ST QTR 86 2/01/86 PAGE 2 OF 2

.a,

UNIT SHUTDOWNS QND POWER REDUCTIONS DOCRET NO. 50 - 352 UNIT MoME LIMERICK UNIT 1 DATE AUGUST 10.1994 REPORT MONTH JULY. 1994 COMPLETED BY PECO ENERGY COMPANY STEVEN J.

KELLEY REPORTS ENGINEER SITE ENGINEERING LIMERICK GENERATING STATION TELEPHONE (610) 327-1200 EXTENSION 3763

- - - - - -... - - - - - - -. - - - _ - _ _ - - - _ _ _ - - -... - _ - - - - _ _ _. - - -.. - _ - - - - - - - - _ _ _ - _ _ _ _.. - - _ - - - -. - - - - - - - - - - - - - _ - - - - - - - - - - - - - - - - - - ~ ~ - - - - - - - - - -

METHOD OF LICENSEE SYSTEM COMPONENT CAUSE AND CORRECTIVE TYPE DURATION REASON SHUTTING DOWN EVENT CODE CODE ACTION TO NO.i DATE (1)

(HOURS)

(2)

REACTOR (3)

REPORT *

(4)

(5)

PREVENT RECURRENCE


_---c....-------

24 940706 S

000.0 H

4 N/A HF TURBIN REACTOR POWER WAS REDUCED TO 95%

DUE TO HIGH TURBINE BACK PRESSURE.

25 940709 S

000.0 B

4 N/A HC HTEXCH REACTOR POWER WAS REDUCED TO 75%

TO SUPPORT CONDENSER CLEANING.

26 940721 S

000.0 H

4 N/A HF TURBIN REACTOR POWER WAS REDUCED TO 96%

DUE TO HIGH TURBINE BACKPRESSURE.

27 940729 5

000.0 H

4 N/A CH PUMPXX REACTOR POWER WAS REDUCED TO 80%

DUE TO A REACTOR FEED PUMP TRIP.

i (1)

(2)

(3)

(4)

F - FORCED REASON METHOD EXHIBIT G - INSTRUCTIONS S - SCHEDULED A - EOUIPMENT FAILURE (EXPLAIN) 1 - MANUAL FOR PREPARATION OF DATA B - MAINTENANCE OR TEST 2 - MANUAL SCRAM.

ENTRY SHEETS FOR LICENSEE C - REFUELING 3 - AUTOMATIC SCRAM.

EVENT REPORT (LER)

D - REGULATORY RESTRICTION 4 - OTHER (EXPLAIN)

FILE (NUREG-0161)

E - OPERATOR TRAINING + LICENSE EXAMINATION F - ADMINISTRATIVE.

(5)

'G - OPERATIONAL ERROR (EXPLAIN)

H - OTHER(EXPLAIN)

EXHIBIT I - SAME SOURCE f

- _ _ - = _ _ - - _ _ _ _ _ _. - _ - _ _ _ _ _ _ _ - - _. _., -.. -

~

Docket No. 50-353 Attachment to Monthly Operating Report for July 1994 Limerick Generating Station Unit 2 July 1 through July 31, 1994 I.

Narrative Summary of Operatina Experiences Limerick Unit 2 began the month of July at a nominal 100% of Rated Thermal Power (RTP).

Power was reduced slightly on July 8 and 9, 1994 due to high turbine backpressure.

On July 3, 1994, at 0835 hours0.00966 days <br />0.232 hours <br />0.00138 weeks <br />3.177175e-4 months <br /> power was reduced to 90% RTP for main turbine valve testing and control rod pattern adjustment.

Power was restored to 100% RTP at 1027 hours0.0119 days <br />0.285 hours <br />0.0017 weeks <br />3.907735e-4 months <br />.

On July 23, 1994, at 0828 hours0.00958 days <br />0.23 hours <br />0.00137 weeks <br />3.15054e-4 months <br /> power was reduced to 91% RTP for main turbine valve testing and a control rod pattern adjustment.

Power was restored to 100% RTP at 1005 hours0.0116 days <br />0.279 hours <br />0.00166 weeks <br />3.824025e-4 months <br />.

Unit 2 ended this operating period at 100% of RTP.

II.

Challences to Main Steam Safety Relief Valves There were no challenges to the Main Steam Safety Relief Valves during the month of July.

i

DVERAGE DAILY UNIT POWER LEVEL

' ~

DOCKET NO. 50 - 353 UNIT LIMERICK UNIT 2 DATE AUGUST 10.1994 COMPANY PECO ENERGY COMPANY STEVEN J.

KELLEY REPORTS ENGINEER SITE ENGINEERING LIMERICK GENERATING STATION TELEPHONE (610) 327-1200 EXTENSION 3763 MONTH JULY 1994 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWE-NET)

(MWE-NET) 1 1054 17 1052 2

1055 18 1052 3

1047 19 1045 4

1055 20 1043 5

1053 21 1044 6

1047 22 1045 7

1051 23 1039 8

1029 24 1040 9

1038 25 1058 10 1050 26 1050 11 1061 27 1053 12 1054 28 1072 13 1049 29 1032 14 1048 30 1048 15 1052 31 1053 4

16 1047 n

m

OPERATING DATA REPORT I'

DOCKET NO. 50 - 353 DATE AUGUST 10.1994 COMPLETED BY PECO ENERGY COMPANY STEVEN J.

MELLEY REPORTS ENGINEER SITE ENGINEERING

+

LIMERICK GENERATING STATION TELEPHONE (610) 327-1200 EXTENSION 3763 OPERATING STATUS 1

UNIT NAME: LIMERICK UNIT 2 NOTES: THERE WERE NO LOAD DRO" 2.

REPORTING PERIOD:

JULY. 1994 GREATER THAN 20% THIS 3.

LICENSED THERMAL POWER (MWT):

3293 MONTH.

4 NAMEPLATE RATING (GROSS MwE):

1138 5.

DESIGN ELECTRICAL RATING (NET MwE):

1055 6.

MAXIMUM DEPENDABLE CAPACITY (GROSS MWE): 1092 7.

MAXIMUM DEPENDABLE CAPACITY (NET MwE):

1055 8.

IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7) SINCE LAST REPORT. GIVE REASONS:

9.

POWER LEVEL TO WHICH RESTRICTED. IF ANY (NET MWE):

10. REASONS FOR RESTRICTIONS. IF ANY:

THIS MONTH VR-TO-DATE CUMULATIVE

11. HOURS IN REPORTING PERIOD 744 5.087 39.983
12. NUMBER OF HOURS REACTOR WAS CRITICAL 744.0 5.087.0 35.729.6
13. REACTOR RESERVE SHUTDOWN HOUR 5 0.0 0.0 0.0
14. HOURS GENERATOR ON-LINE 744.0 5.087.0 35.033.7
15. UNIT RESERVE SHUTDOWN HOURS J.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 2.446.439 16.669.177 111.974.258
17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 809,120 5.573.880 37.066.406
18. NET ELECTRICAL ENERGY GENERATED (MWH) 780.373 5.384.509 35.715.201 PAGE 1 OF 2

OPERATING DATA REPORT (CONTINUED)

DOCKET NO. 50 - 353

~

e DATE AUGUST 10,1994 THIS UONTH YR-TO-DATE CUUULATIVE

19. UNIT SERVICE FACTOR 100.0 100.0 87.6
20. UNIT AVAILABILITY FACTOR 100.0 100.0 87.6 21 UNIT CAPACITY FACTOR (USING MDC NET) 99.4 100.3 84.7
22. UNIT CAPACITY FACTOR (USING DER NET) 99.4 100.3 84.7
23. UNIT FORCED OUTAGE RATE O.0 0.0 3.5 t

24 SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TVPE. DATE. AND DURATION OF EACH):

25. IF SHUTDOWN AT END OF REPORT PERIOD. ESTIMATED DATE OF STARTUP:

5

26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION):

FORECAST ACHIEVED INITIAL CRITICALITY 08/12/89 08/12/89 INITIAL ELECTRICITY 09/01/89 09/01/89 COMMERCIAL OPERATION 02/01/90 01/08/90 b

I e

i PAGE 2 OF 2 h

e

+eg y

m a

UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50 - 353 UNIT NAME LIMERICK UNIT 2 DATE AUGUST 10.1994 REPORT MONTH JULY. 1994 COMPLETED BV PECO ENERGY COMPANY


~~------------

STEVEN J.

KELLEY REPORTS ENGINEER SITE ENGINEERING LIMERICK GENERATING STATION TELEPHONE (610) 327-1200 EXTENSION 3763 l

METHOD 05 l LICENSEE SYSTEM COMPONENT:

CAUSE AND CORRECTIVE TYPE DURATION! REASON SHUTTING DOWN!

EVENT CODE CODE ACTION TO NO.

CATE (1)

(HOURS)l (2)

REACTOR (3) l REPORT *

(4)

(5)

PREVENT RECURRENCE 11 340703 S

000.0 8

4 N/A HA INSTRU REACTOR POWER WAS REDUCED TO 90% FOR MAIN TURBINE VALVE TESTING.

12 940708 5

000.0 M

4 N/A HF TURBIN REACTOR POWER WAS REDUCED TO 97% DUE TO HIGH TURBINE BACKPRESSURE.

N/A HF TURBIN REACTOR POWER WAS REDUCED TO 98% DUE 13 940709 S

000.0 H

4 i

TO HIGH TURBINE BACKPRESSURE.

14 940723 S

000.0 B

4 N/A RB CONROD REACTOR POWER WAS REDUCED TO 91% FOR A CONTROL ROD PATTERN ADJUSTMENT.

(3)

(4)

(1)

(2) e F - FORCED REASON METHOD EXHIBIT G-INSTRUCTIONS S - SCHEDULED A - EQUIPMENT FAILURE (EXPLAIN) 1 - MANUAL FOR PREPARATION OF DATA B - MAINTENANCE OR TEST 2 - MANUAL SCRAM.

ENTRY SHEETS FOR LICENSEE C - REFUELING 3 - AUTOMATIC SCRAM.

EVENT REPORT (LER)

D - REGULATORY RESTRICTION 4 - OTHER (EXPLAIN)

FILE (NUREG-0161)

E - OPERATOR TRAINING + LICENSE EXAMINATION F - ADMINISTRATIVE (5)

G - OPERATIONAL ERROR (EXPLAIN)

H - OTHER(EXPLAIN)

EXHIBIT I - SAME SOURCE i

l l

.