Text
-
= ENTERGY
%""s """ "*' '"*'
KW ind LA 70066 1e! 504 739 6774 R. F. Burski D<. ~.
u m sea, 6.,
m3 W3F1-94-0097 A4.05 j
PR July 14,-1994 U.S. Nuclear Regulatory Commission r
ATTN:
Document Control Desk Washington, D.C. 20555 I
t
Subject:
Waterford 3 SES Docket No. 50-382 i
License No. NPF-38 Monthly Operating Report Gentlemen:
Attached is the subject monthly report which covers the operating statistics for the month of June, 1994. This report is submitted per Section 6.9.1.6 of the Waterford 3 Technical Specifications for Facility Operating License No.
t Very truly yours, tVi R.F. Burski Director Nuclear Safety i
RFB/ssf Attachment cc:
L.J. Callan, (NRC Region IV)
R.B. McGehee N.S. Reynolds
[
F..Yost (Utility Data Institute, Inc.)
J.T. Wheelock (INP0 Records Center)
NRC Resident Inspectors Office (WADM526) l f
.9407150179 94o630 f
a PDR ADOCK 05000392 i
I R
I i
i NRC MONTHLY OPERATING REPORT
SUMMARY
OF OPERATIONS WATERFORD 3 JUNE 1994 The unit operated at an average reactor power of 94.5% and experienced one significant power reduction during the period.
a
\\
PRESSURIZER SAFETY VALVE FAILURES AND CHALLENGES WATERFORD 3 During the month of June 1994, there were no pressurizer safety valve failures or challenges.
s i
1 OPERATING DATA REPORT l
DOCKET NUMBER: 50-382 i
UNIT NAME: WATERFORD 3 DATE OF REPORT: JULY,1994 i
COMPLETED BY:
T.S. BECKER TELEPHONE: 504-739-6683 OPERATING STATUS 1.
Reporting Period: June,1994 Gross Hours in Reporting Period: _720 2.
Currently Authorized Power Level (MWt): 3390 Maximum Dependable Capacity (Net MWe): 1075 Design Electrical Rating (Net MWe): 1104 3.
Power Level to which Restricted (if any) (Net MWe): N/A 4.
Reasons for Restriction (if any): N/A j
THIS MONTH YR TO DATE CUMULATIVE 5.
Number of Hours Reactor was Critical 720.0 3,205.8 64,305.8 6.
Reactor Reserve Shutdown Hours '
7.
Hours Generator was On-line 708.8 3,139.1 63,427.3 8.
Unit Reserve Shutdown Hours -0 9.
Gross Thermal Energy Generated (MWH) 2,306,353 10,364,289 209,392,766
- 10. Gross Electrical Er:ergy l
Generated (MWH) 753,140 3,393,490 69,814,270 i
- 11. Net Electrical Energy Generated (MWH) 717,446 3,226,038 66,536,483
- 12. Reactor Service Factor 100.0 73.8 83.7
- 13. Reactor Availability Factor 100.0 73.8 83.7 i
- 14. Unit Service Factor 98.4 72.3 82.5
- 15. Unit Availability Factor 98.4 72.3 82.5
- 16. Unit Capacity Factor (using MDC) 92.7 69.1 80.5 l
- 17. Unit Capacity Factor (Using DER) 90.3 67.3 78.4
- 18. Unit Forced Outage Rate 0.0 0.6 3,4
i OPERATING DATA REPORT DOCKET NUMBER: 50-382 UNIT NAME: WATERFORD 3 DATE OF REPORT: JULY,1994 COMPLETED BY:
T.S. BECKER TELEPHONE: 504-739-6683 OPERATING DATA REPORT (Con't) 19.
Shutdowns Scheduled over next 6 Months (type, date and duration of each):
N/A 20.
If Shutdown at end of report period, estimated date of startup:
21.
Unit in Commercial Operation THIS MONTH YR TO DATE CUMULATIVE
- 22. Hours in Reporting Period 720.0 4,343.0 76,848.0
- 23. Unit Forced Outage Hours 0.0 20.3 2,199.0 24.
Nameplate Rating (Gross MWe): 1200 25.
If Changes Occur in Capacity Ratings (Items Number 2 and 24) Since Last Report, Give Reasons: N/A
AVERAGE DAILY UNIT POWER LEVEL DOCKET NUMBER: 50-382 UNIT NAME: WATERFORD 3 DATE OF REPORT: JULY,1994 COMPLETED BY:
T.S. BECKER TELEPHONE: 504-739-6683 MONTH JUNE.1994 j
DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-NET)
(MWe-NET) 1 1076 17 1067 2
1075 18 1068 3
1075 19 1068 4
1074 20 1066 5
1073 21 1065 6
1072 22 1063 7
1070 23 1065 8
1069 24 1065 9
1069 25 1066 10 1067 26 1064 11 1068 27 1064 12 463 28 1064 13 293 29 1064 14 541 30 1064 15 830 31 N/A 16 1065 INSTRUCTIONS On this format, list the average daily unit power level in MWe-Net for each day in the reporting month.
Compute to the nearest whole megawatt.
UNIT SHUTDOWNS AND POWER REDUCTIONS C^CKET NUMBER: 50-382 UNIT NAME: WATERFORD 3 DATE OF REPORT: JULY,1994 l
COMPLETED BY:
T.S. BECKER TELEPHONE: 504-739-6683 REPORT FOR JUNE.1994 Type Method of Shutting F = Forced Duration Down the Reactor or Cause, Comments and Number Date S = Scheduled (Hours)
Reason (1)
Reducina Power (2)
Corrective Actions 94-03 940612 F
0.0 H
5 A Reactor Power Cutback was initiated due to a Turbine trip. The Turbine tripped on an invalid 2 out of 3 logic for MSR A2 High Level. The cause of the invalid High Level alarm was a failure to replace insulation on the sensing line for the MSR level switches. The reduced insulation in association with large amounts of rain caused the water level to rise in the float chamber which caused the level switches to actuate.
The sensing lines for the MSR level switches have been insulated.
(1) REASON (2) METHOD A=
Equipment Failure (explain) 1=
Manual B=
Maintenance or Test 2=
Manual Scram C=
Refueling 3=
,D=
Regulatory Restriction 4=
Continuation from Previous Period E=
Operator Training and 5=
Power Reduction License Examination 6=
Other (explain)
F=
Administrative G=
Operational Error (explain)
H=
Other (explain)
.