Forwards Status of Environ Qualification of Electrical Equipment Per 10CFR50.49(g).All Equipment,Except Auxiliary Feedwater Pump Motors,Meets NUREG-0588 Guidelines for Category II Plant
ML20071G993
Person / Time
Site: San Onofre  
Issue date: 05/20/1983
From: Baskin K
SOUTHERN CALIFORNIA EDISON CO.
To: Knighton G
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0588, RTR-NUREG-588 NUDOCS 8305240458
Download: ML20071G993 (5)


Text

e Southern California Edison Company WE P. O. BOX 800 2 244 W ALNUT GROVE AVENU E ROSEMEAD. CALIFORNI A 91770 K. P. B A S KIN vstapwo~s

"""'25 "."'~'o' 2 "c l"~I,'~~ " '"

  • May 20, 1983 s

Director, Office of Nuclear Reactor Regulation Attention:

Mr. George W. Knighton, Branch Chief Licensing Branch No. 3 U. S. Nuclear Regulatory Commission 3

Washington, D.C.

20555 Gentlemen:

Subject:

Docket Nos. 50-361 and 50-362 San Onofre Nuclear Generating Station (SONGS)

Units 2 and 3 The purpose of. this letter is to comply with the requirements of 10 CFR 50.49(g).

The enclosure identifies electrical equipment important to safety that are either environmentally qualified or in the process of being qualified. All equipment except the auxiliary feedwater pump motors neet NUREG-0588 guidelines for a Category II plant (IEEE 323-1971 standard).

However, some equipment will not be assigned a qualified life until additional t' sting has been completed.

The updated status of outstanding items is as follows:

1.

Rosemount Transmitters Foxboro Transmitters These transmiters all have qJalification documentation available i

which meet IEEE 323-1971 requirements.

Since SONGS 283 are l

Category II plants, this complies with HUREG-0588 requirements.

T..e qualification documentation, however, is based on the testing of unaged components and, with the exception of the Rosemount transmitters, separate effects testing methods were used in the qualification process.

In order to improve the qualification of the transmitters and to establish a reasonable qualified life, SCE has joined with other utilities to qualify the transmitt_ers to IEEE 323-1974 specifications.

Full qualification of the transmitters to IEE 323-1974 specifications will be completed prior to March 31, l

1985.

I Soo/

8305240458 830520 s /

PDR ADOCK 05000361

/

P PDR

// /

i

a Mr. G. W. Knighton May 20,.1983 2.

Auxiliary Feedwater Pump Motors The auxiliary feedwater pump motors containing replacement bearings made from cast iron were environmentally qualified for a harsh environment. Due to bearing failures in June,1982 the cast iron bearings were replaced with the originally equipped babbitt bearings. Auxiliary feedwater pump motor environmental qualification was addressed by separate correspondence in the March 7,1983 letter from SCE (K. P. Baskin) to the NRC (G. W. Knighton). The schedule for qualification of this equipment is dependent on NRC acceptance of the proposed hardware modification described in the referenced letter.

If you have any questions or comments, please contact me.

Very truly yours, Enclosure cc: Mr. H. Rood, Project Manager-Licensing Branch No. 3

s ENCLOSURE ENVIRONMENTAL' QUALIFICATION STATUS OF ELECTRICAL EQUIPMENT A.

Fully Qualified Equipment

~ Equipment Name~

Manufacturer Description Fan Motor Reliance Class IE.Inside Containment Motors with Class H, Type RN insulation i

Cable and Wire AMP, Inc.

Radiation Resistant PIDG and Connectors Plasti-Grip Terminals v

600 V Instrumentation Raychem Corp.

Flamtrol insulated cable and Control Cable Heat Trace System Thermon Manufacturing RTD with Kapton-F Resistance Temperature Co.

insulated leads Detector J

Electrical Penetration Westinghouse Medium voltage canister Assembly type s

Low voltage power and control, low level signal and thermocouple modular 4.

type Coax and triax modular type Low voltage power large conductor modular type Heat Shrink Material Raychem, Corp.

WCSF-N sleeving i

NMCK and NPKX motor connection kits HVMC-5 motor connection kit HVT cable termination kit i -

i -

Thermocouple Cable Galite, Inc.

UK6 and TK6 cable Solenoid Valve Valcor VS2600 Series 300 V Instrumentation Rockbestos Firewall III Cable Cable; 600 V Control Cable; SIS Cable i

t

. -, -....,,.. -, -.. _.. - -.. _, -, _,...... - _ - _.., -. _. - - - _ - _ - ~,.. ~ - - - - - - - - _ - - - -.. - -

.--~.,~.,-,-.._.--, -. - -,

T

. Equipment Name Manufacturer Description 8kV Power Cable Anaconda Company EPR insulated cable Electri-Conductor Conax Corp.

Custom built Seal Assembly 600 V Power Cable GE Vulkene Supreme; EPR insulated cable Heat Trace System Wire Thermon, Corp.

TEK cable Level Switch Magnetrol International FLS-X-MPX-SIMD4DC Post-LOCA H2 Monitor GE 47E240609 Thermocouple Weed Instrument Co.

T4B375U-9A Solenoid Valve Automatic Switch Co.

NP8316, 8320, 8321, 8344 Series Circuit Breakers Gould, Inc.

JL and KP Frame Safeguard Pump Motors Westinghouse Outside Containment Nuclear Class IE Motors Resistance Temperature Rosemount 104AFV-1, 104AFC-1 Detector Charging Pump Motor Loui s-Allis CG15C-405TS Fission Detector with General Atomic Co.

RS-C3-2540-102 Integral Cable Spray Chemical Addition Siemans-Allis, Inc.

RG-215T Pump ;4 tor 0

Coax Cable E. J. Stephens, Inc.

RG-71, RG-59 Fan Motor Reliance Class IE outside containment motor with Class H, Type RH insulation Preamplifier / Filter General Atomic Co.

PASQ1 Assembly Level Transmitter Transamerica DeLaval, XM-36498, XM-62475, Gems Sensor Div.

XM-51410 Coax Cable Brand Rex Co.

CS-71546, CD-95146 Valve Position Monitor Technology for Energy TEC 1414 l

Co.

(

L

. Equipment Name Manufacturer Description Radiation Monitor General Atomic Co.

RD-23 Detector Valve Motor Actuator Limitorque Corp.

SMB, SB series with Class RH or Class B insulation Main Steam Isolation W-K-M 40"x30"x40" GSO MD2 Valve POW-R-SEAL MSIV Solenoid Valve Target Rock Corp.

75G Series through 75G-025 Coax Cable Connectors Amphenol Type "N", plug models 34520-1000, 82-5585-1000; jack models 18250-1000, 82-5526-1000; 82-63; 82-61; 4900; 82-814-1000 Hydrogen Recombiner Westinghouse Custom built Hydromotor Valve ITT NH93 Operator Limit Switch NAMC0 EA-180 Series Coax Cable Boston Insulated Wire 12094-C-G22 B.

Equipment Undergoing Test Qualified for first cycle operation based on IEEE 323-1971 vintage test reports.

Full qualification will occur prior to March 31, 1985.

Equipment Name Manufacturer Description Pressure Transmitter Foxboro Co.

E-10 Series; NE-10 Series Pressure Transmitter Rosemount 1140 Series A C.

Equipment Not Qualified Equipment Name Manufacturer Description Auxiliary Feedwater Siemans-Allis EL8-90247 Pump Motor GPvH:8101

]

_n,.

-.g