ML20071F243

From kanterella
Jump to navigation Jump to search
Std Rept of Personnel & Man-Rem by Work & Job Function, 1982
ML20071F243
Person / Time
Site: Ginna 
Issue date: 02/28/1983
From:
ROCHESTER GAS & ELECTRIC CORP.
To:
Shared Package
ML17256A549 List:
References
NUDOCS 8303140441
Download: ML20071F243 (2)


Text

r FOBERT E. GINNA STATION STANDARD REPORP OF PERSONNEL AND MAN-REM BY WORK AND JOB FUNCTION FOR THE YEAR OF 1982 WORK & JOB FUNCTION NUMBER OF PERSONNEL

'IDIAL MAN - REM REACIOR OPERATIONS C WrRACT STATION UTILITY C WrRACP STATION UTILITY

& SURVEILLANCE WORKERS EMPIOYEES EMPIDYEES WORIIRS EMPIDYEES EMPIOYEES MAINTENANCE PERSONNEL 217 40 245 28.777 4.584 7.089 OPERATING PERSONNEL 0

31 2

0.000 16.623 0.796 HEAL'IU PHYSICS PERSONNEL 30 14 3

5.385 3.831 0.285 SUPERVISORY PERSONNEL 28 14 11 2.102 3.573 0.819 ENGINEERING PERSONNEL 50 2

8 3.075 0.250 0.230 ROUTINE MAINTENANCE MAINTENANCE PERSONNEL 256 41 241 57.663 14.791 74.411 OPERATING PERSONNEL 0

27 2

0.000 0.672 0.022 HEALTH PHYSICS PERSONNEL 30 14 2

6.506 2.766 0.010 SUPERVISORY PERSONNEL 29 13 9

3.856 1.136 0.279 ENGINEERING PERSONNEL 47 1

6 2.998 0.212 0.681 INSERVICE INSPECflON MAINTENANCE PERSONNEL 18 18 21 0.422 0.206 0.226 OPERATING PERSONNEL 0

0 0

0.000 0.000 0.000 HEAUlU PHYSICS PERSONNEL 9

8 1

0.280 0.135 0.000 SUPERVISORY PERSONNEL 11 10 6

0.913 0.421 0.438 ENGINEERING PERSONNEL 1

1 1

0.055 0.000 0.178 SPECIAL MAINTENANCE MAINTENANCE PERSONNEL 292 41 260 224.849 26.147 419.138 OPERATI?G PERSONNEL 0

30 2

0.000 3.017 0.405 HEALTH PHYSICS PERSONNEL 30 13 3

16.613 21.020 0.322 SUPERVISORY PERSONNEL 39 14 12 27.354 8.919 9.635 ENGINEERING PERSONNEL 70 2

7 49.737 0.235 8.100 NASTE PROCESSING MAINTENANCE PERSONNEL 16 25 44 1.974 2.189 1.233 OPERATING PERSONNEL 0

18 1

0.000 1.317 0.015 HEAUIH PHYSICS PERSONNEL 20 12 1

1.700 0.857 0.001 SUPERVISORY PERSONNEL 5

2 0

0.368 0.160 0.000 ENGINEERING PERSONNEL 8

0 0

1.525 0.000 0.000 REFUELING MAINTENANCE PERSONNEL 14 28 29 4.095 2.105 6.944 OPERATING PERSONtEL 0

3 0

0.000 3.290 0.000 HEAUIH PHYSICS PERSONNEL 13 8

0 1.818 0.478 0.000 SUPERVISORY PERSONNEL 1

3 0

0.340 0.546 0.000 ENGINEERING PERSONNEL 17 0

0 15.205 0.000 0.000

'IUTALS MAINPENANCE PERSONNEL 324 41 266 317.780 50.022 509.041 OPERATING PERSONNEL 0

31 2

0.000 24.919 1.238 HEAL'IH PHYSICS PERSONNEL 30 14 3

32.302 29.087 0.618 SUPERVISORY PERSONNEL 39 14 12 34.933 14.755 11.171 ENGINEERING PERSONNEL 88 2

8 72.595 0.697 9.189 GRAND 'IOTALS l

481 l

102 l

291 l 457.610 l 119.480 l 531.257_

8303140441 830228 PDR ADOCK 05000244 R

PDR

e-R)CHESTER GAS & ELECTRIC OORPORATION ROBERT E. GINNA NUCLEAR STATION STANDMD REPORP OF PERSONNEL WHOLE E)DY EXPOSURE ( REM )

BY EXPOSURE GIOUPS EDR YEAR OF 1982 REQUIRED AS PER 10 CFR 20 PARAGRAPH 20.407(b)

NUMBER OF PEOPLE IXM LIMIT HIGH LIMIT EACH GROUP (REM)

(REM) 436 WI'IH NO EXPOSURE 248 0.001 0.099 130 0.100 0.249 131 0.250 0.499 125 0.500 0.749 76 0.750 0.999 219 1.000 1.999 109 2.000 2.999 45 3.000 3.999 34 4.000 4.999 0

> 5.000 NONE WITH GREATER THAN 5.000 REM.

'IUTAL NUMBER OF MONI'IORED INDIVIDUALS = 1,553