Forwards Replacement Pages to 821122 Application to Amend License DPR-40,changing Tech Spec Limit on Total Planar Radial Peak Factor
ML20071D128
Person / Time
Site: Fort Calhoun 
Issue date: 02/28/1983
From: William Jones
OMAHA PUBLIC POWER DISTRICT
To: Clark R
Office of Nuclear Reactor Regulation
Shared Package
ML20071D130 List:
References
LIC-83-052, LIC-83-52, NUDOCS 8303090204
Download: ML20071D128 (1)


Text

. _ _ _ _ _ _ _ _ _ _

Omaha Public Power District 1623 HARHEY e OMAHA. NEBRASKA 68102 e TELEPHONE 536 4000 AREA CODE 402 l

February 28, 1983 LIC-83-052 j

Mr. Robert A.

Clark, Chief i

U.

S.

Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Licensing Operating Reactors Branch No. 3 Washington, D.C.

20555

Reference:

Docket No. 50-285

Dear Mr. Clark:

License Amendment Application for the Fort Calhoun Station Cycle 8 Reload The subject application, submitted to the Commission on November 22, 1962, provided supporting analyses based upon a Cycle 7 fuel burnup of 10,500 MWD /T.

This burnup was consistent with an expected refueling outage start date of January 4, 1983.

However, as a result of a main turbine generator failure, the Fort Calhoun Station refueling commenced a month earlier than anticipated, at a Cycle 7 burnup of 9,725 MWD /T.

The lower Cycle 7 burnup required the District to verify the existing analyses to ensure that they were still bounding for Cycle 8.

This verification process identified the need for a change to the subject application, as related to the Technical Specification limit on the total planar radial peaking factor.

Accordingly, please find attached the District's replacement pages 1-2, 2-57a, and Figure 2-9 to the November 22, 1982 application.

A supplemental justification for these changes in also provided.

Since' rely,

( bl/jUW W.

C. Jones Division Manager Production Operations WCJ/TLP:jmm Attachment cc:

LeBoeuf, Lamb. Leiby & MacRae 1333 New Hampshire Avenue, N.W.

Washington, D.C.

20036 Mr.

L. A. Yandell, NRC l

.9 nior Resident Inspector 8303090204 830228 PDR ADOCK 05000285 P

cpf em__