a VIHUINIA ELEcTHIC AND POWER COMI%NY H IC H M OND, VI HGINIA 23261 February 23, 1994 j

United States Nuclear Regulatory Commission Serial No.94-036 Attention: Document Control Desk NL&P/EJW Washington, D.C. 20555 Docket Nos.

50-338 50-339 Ucense Nos. NPF-4 NPF-7 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNITS 1 AND 2 1993 ANNUAL STEAM GENERATOR INSERVICE INSPECTION REPORT i

in accordance with the requirements of Technical Specifications 4.4.5.5 b and 6.9.1.4, i

Virginia Electric and Power Company hereby submits the 1993 Steam Generator Inservice Inspection Report for North Anna Power Station Units 1 and 2.

During the 1993 Spring refueling outage for North Anna Power Station Unit 1, the steam generators were replaced. As such, no inservice inspection results for Unit 1 are included in this report.

4 During the 1993 Fall refueling outage for North Anna Power Station Unit 2, the tubes in each unit's "A", "B", and "C" steam generators were examined. The information in i summarizes the results of those examinations. The information includes the number and extent of the tubes examined, location and characterization of each Indication of an imperfection, identification of the tubes that were plugged, and a glossary of the terms used in the report. Please note that the specific information provided in Attachment 1 has been revised since the 90 day report was submitted on January 24,1994. These changes were the result of further engineering reviews and therefore supersede the information previously provided.

l Should you require additional information, please contact us.

Very truly yours, lk M. L Bowling, Manager Nuclear Licensing and Programs Attachment f

d 94o3o4 25'5 94o223 f(;I PDR ADOCK 05ooo338 Q

w PDR

,-,r-.

-n

oc:

United States Nuclear Regulatory Commission Region il 101 Marietta Street, N.W.

Suite 2900 Atlanta, GA 30323 Mr. R. D. McWhorter NRC Senior Resident inspector North Anna Power Station i

l l

l I

i i

I m_ _,, -,___-,,_,