a SYSTEM DESCRIPTION FOR RADIO CONTROLLED PROMPT ALERT AND NOTIFICATION SYSTEM FOR CATAWBA NUCLEAR STATION NEWPORT, S. C.
8302180402 030210 PDR ADOCK 05000413 F
PDR EL4010lY m.
_,___m__
,--p-m
,_ _ _.__-.,. _, -m,_
_7, y
TABLE OF CONTENTS Section Title Page
- 1. 0 SCOPE 1
2.0 REFERENCES
2 3.0 DESIGN CRITERIA 3
4.0 SYSTEM DESCRIPTION 4
5.0 AREA POPULATION DENSITY 5
6.0 POWER DISTRIBUTION AND RELIABILITY 6
a 7.0 SYSTEM CONTROL 7
8.0 SYSTEM TESTING AND MAINTENANCE 8
TABLES 3.1 THEORETICAL SIREN COVERAGE / RANGE 4.1 SIREN SITE INFORMATION TABULATION 5.1 1981 PROJECTED POPULATION DISTRIBUTION 8.1 SYSTEM TESTING AND MAINTENANCE FIGURES 3.1 RANGE CALCULATION FORMULA 4.1 SIREN SITE LOCATION MAP 4.2 MAJOR TRANPORTATION ROUTES 5.1 POPULATION DENSITY 0-10 MILES 6.1 POWER DISTRIBUTION GRID EL40101Y
- -~,
SYSTEM DESCRIPTION PUBLIC NOTIFICATION SYSTEM CATAWBA NUCLEAR STATION 1.0 SCOPE The public notification system as required by 10CFR50 and NUREG-0654, Appendix 3 will be implemented using fixed sirens in the Emergency Planning Zone around the Catawba Nuclear Stc; ion.
Large area warning systems are most economical and effective where the action necessary, once the siren is sounded, is simple and understood by the public.
The public will be made aware of the purpose of the siren sounding which is netice to listen to the Emergency Broadcast System (EBS) radio or television station for specific information and instructions concerning the situation at the Catawba Nuclear Station.
The Common Program Control Station (CPCS-1) is designated as WEZC-FM located in Charlotte, N. C.
The sirens will be sounded in the " ALERT" (Civil Defense) signal mode which is a three (3) minute steady signal.
W 1
2.0 REFERENCES
NUREG-0654, Appendix 3/ FEMA-REP-1, Revision 1, " Criteria for Preparation and Elevation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," (V. S. Nuclear Regulatory Commission, Washington, D. C. and Federal Emergency Management Agency, Washington, D. C.).
CPG-1-17, " Outdoor Warning System Guide," dated March, 1980 (U. S. Federal Emergency Management Agency, Washington, D. C.).
Guidance Memorandum #13, June 17, 1980 (U. S. Federal Emergency Management Agency, Washington, D. C.).
e 2
1 3.0 DESIGN CRITERIA System design criteria is as follows:
3.1 Within fifteen (15) minutes of the State / County determination that public protective actions are necessary, provide Alert (sirens) and Notification (EBS) to the population within the Catawba Nuclear Station Emergency Planning Zone.
3.2 Provide a siren system with an acceptable dissonant sound level 10 dB above average daytime ambient background noise of 50 dB(a) for areas with a population below 2000 persons per square mile, and 10 dB above average daytime ambient background noise of 60 dB(a) for areas above 2000 persons per square mile.
(Density to be determined in 1 mila radial, 22 sectors.)
3.3 Locate sirens considering the demography, topography, and heavy industry within the area.
3.4 Limit siren sound level received by an person to less than 123 dB(c).
3.5 Limit siren sizes /models to 125 dB and 113 dB (dB(c) at 100 feet) to minimize the number of different models which simplifies the task of long-term support.
3.6 Use a conservative sound propagation loss factor of 10 dB per distance doubled to compute siren coverage.
This results in the 125 dB model providing a 9050' radius coverage and the 113 dB model providing a 3950' radius coverage per Table 3.1 (Range calculated per the formula shown in Figure 3.1).
3.7 Radio-controlled tone activation from each county for those sirens within their boundaries.
3.8 Existing alerting equipment, such as Volunteer Fire Department sirens, will not be utilized in this primary system.
3.9 Provide adequate all-weather maintenance access.
3.10 Paint equipment to provide blending with the surroundings to minimize the prominence of the siren installation.
3.11 All equipment will be designed for a forty (40) year life in an outdoor environment with normal maintenance and parts replacement.
3.12 The siren equipment shall be capable of producing both the Civil Defense
" Alert" (steady) signal and " Attack" (wavering) signal.
The counties may actuate either of these two (2) signals with the proper encoder code selection.
3.13 The siren equipment will be designed to provide continuous duty (sized for continuous repetitive three (3) minute cycles).
3
1 TABLE 3.1 THEORETICAL SIREN COVERAGE / RANGE IN FEET WITH 10 dB LOSS PER DISTANCE DOUBLED Minimum 125 dB(c) 113 dB(c)
Level. Coverage Rated Rated in dB(c)
Siren Siren 85 1600' 80 2250' 1000' 75 3200' 1400' 73 3700' 1600' 70 4500' 2000' 68 5200' 2250' 65 6400' 2800' 60 9050' 3950' Note: All ranges rounded off to nearest 50 ft.
i h
Y l
I e
~ RANGE CALCULATIONS Lo-LX d
Rx = Ro x2 4
WilERE:
R
=
RANGE IN FEET x
RANGE IN FEET bHERE SL* IS KNOWN R
=
o DESIRED SL* AT RANGE R Lx
=
x SL* AT RANGE R L
=
o o
LOSS IN dB PER DISTANCE DOUBLED d
=
SOUND LEVEL IN dB (C)
- SL
=
4 4
I FIGURE 3.1 I
4.0 SYSTEM DESCRIPTION The Emergency Planning Zone (EPZ) around the Cattwba Nuclear Station includes areas in York Costy, South Carolina and Mecklenburg County, and Gaston County, North Caroline.
The siren system network to provide a minimum of 60 dB(c) area coverage will consist of sixty-four (64) fixed siren locations as shown on Figure 4.1.
Sixty-three (63) of this total will be of the 125 dB(c) siren rating each cover-ing a 9050 feet radius area and the remaining one (1) will be 113 dB(c) rated covering a 3950 feet radius area.
Table 4.1 lists additional siren siting information.
The sirens will be radio-controlled, tone actuated, for each of the counties for those sirens located within their boundaries.
The counties will be provided with a tone encoder to be connected to an existing radio transmitter to be designated by county officials.
York County will control forty-nine (49) sirens, Mecklenburg County will control ten (10) sirens, and Gaston County will control five (5) sirens.
The sirens will be located along existing highways and roads that traverse the Emergency Planning Zone.
The major transportation routes for the 0-10 mile radius area are shown in Figure 4.2.
The siren installation will consist of the siren components (model dependent),
a radio receiver / tone decoder, radio antenna, motor starter control box, and miscellaneous electrical service components.
The mounting height of the siren horn assembly will be a minimum of fifty (50) feet above the ground with all siren and support components mounted on a wood pole.
Equipment from the pole top to the ground will be painted brown and the equip-ment above the pole top will be painted gray.
The proposed siren system provides reasonable assurance that coverage approach-ing the design objectives will be achieved.
However, there are limitations in employing an outdoor warning system with the expectation of achieving 100 percent notification to the public.
This is because of the many variables including weather conditions, tree foliage, local topography, and competing noise sources inside and outside dwellings.
The majority of the people not alerted by the siren sound due to other noise sources or sound attenuation variables may well be watching TV or listening to radio.
In that case the special emergency announcements made on the EBS radio and TV stations would l
attract their attention.
Even with a higher level siren signal, there is a possibility that the system could not assure alerting everyone who is indoors in a high ambient noise area.
4 L
CATAK9A 1 & 2 PUBLIC NOTIFICATICd SYSTEM - SIRENS SITE INFORMATION TABULATION 01-10-83 Table 4.1 SITE SIREN MOUNTING PWR.
LAND NO.
LOCATION SIZE HEIGHT C0VERAGE UTILITY SERVICE STATUS COMMENTS 1
NC 49 (York Road) at Lake 125 50' 9050' DP Co.
240V RN Mecklenburg County Shore Drive approximately.3 10 mile from Buster Boyd Bridge 2
SC 49 Just past Buster Boyd 125 50' 9050' DP Co.
240V R/W York County Bridge on right side near 10 Hungry Fisherman Restaurant 3
Off SC 49 on road to River 125 50' 9050' DP Co.
240V RN York County Hills rear entrance (west side la Trans. R/W near River Hills Church) 4 Cook Road off SC 55 125 50' 9050' DP Co.
240V Private York County (approximately 150' from 10 intersection) 5 SC 49 next to Crowder's Creek 125 50' 9050' York 240V RN York Count' access area 10 6
SC 274 near ")0KV RN (at 125 50' 9050' York 240V R/W York County road leading to Catawba 10 Nuclear Station) 7 SC 1099 at end of pavement 125 50' 9050' York 240V RN York County (1.8 mile from Five Points) 10 8
Intersection SC 49 & CR 114 125 50' 9050' York 240V RN York County 10 9
Intersection CR 815 & 817 125 50' 9050' York 240V RN York County 10 EL40101Y
CATAWBA 1 & 2 PUBLIC NOTIFICATION SYSTEM - SIRENS SITE INFORMATION TABULATION 01-10-83 Table 4.1 (Continued)
SITE SIREN MOUNTING PtlR.
LAND NO.
LOCATION SIZE HEIGHT COVERAGE UTILITY SERVICE STATUS COMMENTS 10 SC 274 near Trans. R/W 125 50' 9050' DP Co.
240V R/W York County approximately 200 yards from 10 intersection with CR 195 11 Allison Creek Road, CR 1081 125 50' 9050' York 240V R/W York County approximately 1 mile from 10 SC 274 12 Off CR 1182 beyond Catawh3 125 50' 9050' York 240V R/W York County Station entrance, left at 10 pavement end on dirt road at 44KV R/W 13 SC 195 across from China Grove 125 50' 9050' York 240V R/W York County A.M.E. Zion Church, approxi-10 mately 300 yards from 195/658 intersection 14 SC 658 (west side) approxi-125 50' 9050' DP Co.
240V R/W York County mate'y 200 south of Museum 10 Road intersection 15 SC 195 at corner of Falconwood 125 50' 9050' York 240V R/W York County Road across from Lakewood 10 Baptist Church 16 SC 741 near Trans. Line R/W 125 50' 9050' York 240V R/W York County 10 17 Tega Cay, Molokia Drive prior 125 50' 9050' DP Co.
240V Private York County to Clubhouse entrance (right 10 Tega Cay side of road 100' prior to transformer box).
EL40101Y
CATAWBA 1 & 2 PUBLIC NOTIFICATION SYSTEM - SIRENS SITE INFORMATION TABULATION 01-10-83 Table 4.1 (Continued)
LAND NO.
LOCATION SIZE HEIGHT C0VERAGE UTILITY SERVICE STATUS ComENTS 18 SC 160 at rear entrance 125 50' 9050' York 240V R/W York County (gravel road) to Big Highway 10 160 junkyard 19 McKee Road (CR 1102) at 115 50' 3950' DP Co.
240V RN Mecklenburg County curve (east side) 10 20 Snug Harbor Road at S8/9 125 50' 9050' DP Co.
240V R/W Mecklenburg County gravel road 10 21 Corner Hamilton Road and 125 50' 9050' DP Co.
240V R/W Mecklenburg County Youngblood Road across from 10 A.M.E. Zion Church 22 Carowinds Blvd. (1441) across 125 50' 9050' DP Co.
240V RN York County from intersection with SC 22 10 (Carowinds side of road) 23 Westinghouse Blvd. across from 125 50' 9050' DP Co.
240V R/W Mecklenburg County Titan Building Products near 10 fire hydrant 24 NC 160 across from Aplix Plant, 125 50'
.9050' DP Co.
240V RN Mecklenburg County approximately 300 yards from 10 Sam Neely Road intersectien 25 Sandy Porter Road (1142) at 125 50' 9050' DP Co.
240V RN Mecklenburg County end of white fence approxi-10 mately 500' from intersection with Brown Grier Road 26 Shopton Road west (1116) in 125 50' 9050' DP Co.
240V RN Mecklenburg County i
curve at power pole with 10 address 10220 marked l
EL40101Y l
l
CATAWBA 1 & 2 PUBLIC NOTIFICATION SYSTEM - SIRENS SITE INFORMATION TABULATION 01-10-83 Table 4.1 (Continued)
LAND N0.
LOCATION SIZE HEIGHT COVERAGE UTILITY SERVICE STATUS COMMENTS 27 Shopton Road west at Winget 125 50' 9050' DP Co.
240V RN Mecklenburg County Road (opposite side from road 10 marker) 28 NC 273 just prior to trailer 125 50' 9050' York 240V RN Gaston County park at telephone pedestal #9 10 approximately \\ mile from end i
of road 29 Pole Branch Road (177) 125 50' 9050' Ruthford 240V RN Gaston County approximately 1000' beyond Elect.
10 bridge 30 Ratchford Road (2431) off 125 50' 9050' DP Co.
240V
- RN Gaston County 2485 about 200' from 10 intersection 31 NC 274 approximately 400' 125 50' 9050' DP Co.
240V RN Gaston County north of 2429/274 intersection 10 across from " Curve" Road sign 32 SC 435 ~ 200' from old 125 50' 9050' York El.
240V RN York County grocery store 10 33 SC 2427 & 564 125 50' 9050' DP Co.
240V RN Gaston County 10 4
34 Intersection 64/27 next to 125 50' 9050' DP Co.
240V RN York County gravel road 10 35 SC 557 south side of road 125 50' 9050' DP Co.
240V RN York County beyond road to Amity Estates 10 EL40101Y
CATAWBA 1 & 2 PUBLIC NOTIFICATION SYSTEM - SIRENS SITE INFORMATION TABULATION 01-10-83 Table 4.1 (Continued)
LAND NO.
LOCATION SIZE I.iIGHT COVERAGE UTILITY SERVICE STATUS COMMENTS 36 Intersection 557/55 (northeast 125 50' 9050' York El.
240V RN York County side) 10 37 Clover, back of parking lot 125 50' 9050' DP Co.
240V Private-York County behind Clover Police / Fire 10 Clover Department 38 SC 64 across from gravel road 125 50' 9050' York 240V RN York County
.2 mile north of Johnson 10 Branch Bridge 39 SC 732 approximately 150' from 125 50' 9050' York 240V RN York County intersection 732/738, north 10 side of road 40 SC 172 (north side) just past 125 50' 9050' York 240V RN York County intersection 64/172 10 41 SC 819 near intersection 125 50' 9050' York 240V RN York County 819/818 10 42 SC 161 past A.M.E. Zion Church 125 50' 9050' DP Co.
240V RN York County near softball field backstop 10 fence 43 York, at rear of DP Co.
125 50' 9050' DP Co.
240V Private-York County Retail Office parking lot 10 DP Co.
44 Intersection SC 1451/347 125 50' 9050' York 240V RN York County 10 45 SC 195 across from DP Co.
125 50' 9050' DP Co.
240V RN York County pole #36 10 EL40101Y
CATAWBA 1 & 2 PUBLIC NOTIFICATION SYSTEM - SIRENS SITE INFORMATION TABULATION 01-10-83 Table 4.1 (Continued)
LAND NO.
LOCATION SIZE HEIGHT COVERAGE UTILITY SERVICE STATUS COMMENTS 46 SC.u2, near intersection 125 50' 9050' York 240V R/W York County of LR 1108 10 47 Rock Hill, intersection 125 50' 9050' DP Co.
240V RN York County Rawlinson Road & SC 5 10 between two schools 48 Rock Hill, Friedheim Road at 125 50' 9050' Rock Hill 240V Rock Hill York County rear of Sunset Park Elem.
Util.
10 School School property Sys.
49 Rock Hill, Spruce & Sylvia 125 50' 9050' Rock Hill 240V Rock Hill York County St. at Sylvia Elem. School Util 10 School near 30 power pole at dumpster Sys.
50 Rock Hill, Northside Elem.
125 50' 9050' Rock Hill 240V Rock Hill York County School (Anafrel St.), existing Util.
10 School RH siren site Sys.
51 Rock Hill, at Water Works 125 50' 9050' Rock Hill 240V Rock Hill York County Office on Columbia Ave.
Util.
10 RN (corner of fence at parking lot) 52 Rock Hill, Herlong Road at 125 50' 9050' Rock Hill 240V RN York County Village Shopping Center Until.
10 (existing RH siren site) 53 Rock Hill, India Hook Road 125 50' 9050' Rock Hill 240V RN York County across from Ebinport Elem.
Util.
10 School at Animal Clinic EL40101Y
CATAWBA 1 & 2 PUBLIC NOTIFICATION SYSTEM - SIRENS SITE INFORMATION TABULATION 01-10-83 Table 4.1 (Continued)
LAND NO.
LOCATION SIZE HEIGHT C0VERAGE UTILITY SERVICE STATUS COMMENTS 54 Rock Hill, Cherry Road at 125 50' 9050' Rock Hill 240V Rock Hill York County McNair St. (existing RH Util.
10 siren site) 55 Rock Hill, Dave Lyle Blvd. at 125 50' 9050' York 240V R/W York County Industrial Park Ent.
10 (Garrisons and Gaskins Road) 56 SC 21 across from Celanese 125 50' 9050' Rock Hill 240V R/W York County Celriver Plant near road Util 10 sign 57 Doby Bridge Road at corner 125 50' 9050' DP Co.
240V R/W York County of Williams Road 10 58 Fort Mill, Massey Road next 125 50' 9050' DP Co.
240V Private-York County to Cook's Big A Auto Parts la DP Co.
(near Water Tower & Fort Mill Ret. #1 substation) 59 Steele Road (Rt. 270) just 125 50' 9050' York 240V R/W York County past intersection with 10 Merritt Road across from peach orchard entrance 60 SC 160 at CR 49 & entrance 125 50' 9050' York 240V R/W York County to I-77 South access ramp 10 (near telephone pedestal) 61 Gold Hill Road (SC 98) near 125 50' 9050' York 240V R/W York County Trans. R/W approximately 10 300' from I-77 South ramp EL40101Y
CATAWBA 1 & 2 PUBLIC NOTIFICATION SYSTEM - SIRENS SITE INFORMATION TABULATION 01-10-83 Table 4.1 (Continued)
LAND NO.
LOCATION SIZE HEIGHT COVERAGE UTILITY SERVICE STATUS COMMENTS 62 Bus. 21 near intersection with 125 50' 9050' York 240V R/W York County CR 1480 (side next to corn 10 field) 63 Pineville, at Vol. Fire Dept.
125 50' 9050' Pineville 240V Fire Dept.Mecklenburg County near southwest corner of Util.
10 Pineville building 64 SC 5, prior to Fishing Creek 125 50' 9050' York 240V R/W York C :.ty (north side before curve) 10 I
i l
EL40101Y
e l
~1 L.DOCUVlENT cE PAGE l
PULLED ANO.
~
NO. OF PAGES-REASON O PAGEtifG S2 D MAC CChiFnED A1. PDR CF 014R =
D DE11ER COmf R100E50 DN z]
3_
PAGE100 LARG110PEM.
~
gMAC4;ChrFEID Al PDR 014R
~
D FnutD On M Rionicn >no =
~
0
O l
DOCU EN; PAGE
~
PUiLE AI\\O.me--
b NO. OF PAGES-i REASON I
C PAGE ILLEGIB2 O HARD COPY FILED AT. PDR CF OTHER
/
1__
D BET 1ER COP ( REQUESTED ON _
$ PAGE 100 LARGE 10 FILM.
D HARD COP ( FidD AT: PDR FJ OTHER h FILMED ON APERTURE CARD N Yk
(%%\\RCRo%.o2
5.0 AREA POPULATION DISTRIBUTION Several communities are located in the Emergency Planning Zone around the Catawba Nuclear Station.
The larger communities include River Hills Plantation (approximately four (4) miles north), Tega Cay (r.pproximately two (2) miles southeast), Lakewood (approximately three (3) miles south), and Newport (approximately five (5) miles southwest).
Note Table 5.1 from the Final Safety Analysis Report for Catawba projecting 11,859 people in 1981 in the 0-5 mile radius area of 78.5 square miles.
This yields approximately 150 persons par square mile which is well below the " rural" classification of 2000 or less people per square mile.
In the 5-10 mile area of the EPZ are the cities of Rock Hill, York, Clover, Pineville, and Fort Mill.
For alerting purposes, each of the city limit areas are considered above 2000 persons per square mile although portions of Rock Hill are the only areas above that figure at this time.
5
.. TABi.E 5.1 Catawba Nuclear Station 1981 Projected Pooulation Distribution 0-10 Miles (0-16.1 km) 0-1 1-2 2-3 3-4 4-5 5-10 SECTOR MILE MILES MILES MILES MILES MILES TOTAL N'
4 56 55 912 420 277 1,724 NNE 6
42 -
200 427 302 898 1,875 NE O
51 66 103 125 3,950 4,295 ENE 3
55 27 112 173 880 1,250 E
3 27 17 114 333 527 1,021 ESE 23 106 921 817 119 6,430 8,416 SE
'O 34 271 751 416 6,865 8,337 SSE 3
31 303 414 717 31,383 32,851 5'-
20 30 111 303 405 2,830 3,699 SSW 10 50 212 263 318 702 1,555 SW 9
15 76 61 101 327 509 WSW 0
17 47 44 50 1,284
.1,442 W
3 23 3
69 90 715 903 WNW 0
79 24
'79 89 3,640 3,911 NW 0
81 29.
44 253 326 733 NNW 0
40 25 126 101 724 1,016 TOTAL 84 737 2,387 4,639 4,012 61,758 73,617 l
e
-s-. -.
POPULATION BY SECTOR, 0-10 MILE EPZ FIGURE 5.I CUT 1ULATIVE O-1 MILE =
'84 1 MILE a 84 1 - 2 MILE 737 2 MILE =
821 2 - 3 MILE =
2,387 3 MILE 3.208 3-4 MILE a 4,639 4 MILE
- 7,847 4 - 5 MILE a 4,012 5 MILE
- 11,85%
5 - 10 M ILE 61,758 10 MILE
- 73,617 N
%e 7:4 h
328 3950 420 N
801 302
~
els 253 II8 4II 125 3
3e40 44 58 103 800 25 200 2
73 4
42 112 79 SS 715 90 49 3l 23 3 27 i 17 114 333 E
17 10s 47 15 34 321 76 271 50
'I' 212 303 St II3 758 g
lot I83 303 g
1294 S430 Q
388 717 408 327 4865 h
702 31383 Ssy gs me30 g
S
6.0 POWER DISTRIBUTION AND RELIABILITY The electrical power distribution for the siren system is very reliable as shown on Figure 6.1.
The power is derived from more than five (5) power t
stations in the EPZ vicinity and flows in from at least five (5) directions.
In addition to this redundancy, the more than six (6) substations within the area are interconnected.
The loss of an individual substation or power source would not result in a total siren system failure.
t 6
l l
l l
l l
l l
s N
I N
O I
A T
D 6
W L
A I
O D
T R
N O
S G
E O
R N
R W
E O
U W
I G
O O
r I
T C.
P f
F lB M.
R I
E A
R E
T L
S K
C I
R U
D O
N Y
R A
E B
W A.
2 W
O 8
S A
P K -
L T
9 L
A 1
O A
C R
F Y 4 D
B Y
T M
A N
I I
E W E E
R A T I
G R A M
L D D E
Y O
T W
T N
I' E,L
\\
L J
/
LI A
IC T
Ll L I
l ECI W
RA RS S
IITUT EL EI E VL N
I BCR II O
Ri C.
I l
T
^
M.
AT E
SBU S
6 C.
TR M.
O TC E
P J
W E
L A ;
N INO N
T O
S I
A T
G AT O
S T
R EW i
O E
P I
T E
I R
T l
EV O
K O
C R
L A
O C
P Y
O O
O T
T T
l l
l ll
7.0 SYSTEM CONTROL The siren system will be radio-controlled from each county using an existing county selected radio frequency.
A tone encoder will be installed in the county communications center which provides specific tones and timing sequences to be sent to the transmitter.
The tone encoder requires a key to enable its functions.
These siren sites within the county boundaries will actuate in the selected mode as the tones are received and decoded at each site.
Radio control tone commands include three separate codes which are " Alert", " Attack",
and " Cancel".
The " Alert" code activation will produce a three (3) minute steady signal or shorter if the " Cancel" code is sent.
Only the " Alert" and
" Cancel" commands are used for the Catawba EPZ procedures.
The county may elect to use the " Attack" mode for other purposes.
Local manual controls are provided at each siren site within locked enclosures for maintenance and checkout purposes.
County emergency preparedness authorities having system activation responsibility are as follows:
York County Mr. James L. Carroll, Director, York County Emergency Management located in York, S. C.
Mecklenburg County Mr. Kenneth Williams, Director, Civil Preparedness located in Charlotte, N. C.
Gaston County Mr. Robert Phillips, Director, Gaston County Emergency Management Agency, Gastonia, N. C.
7
8.0 SYSTEM TESTING AND MAINTENANCE The tests listed per Table 8.1 will be routinely performed on the indicated schedule to insure siren system reliability and operational readiness.
The Silent test will be conducted by the county control center personnel.
The quarterly Growl test will normally be performed by Duke Power Company personnel locally at each siren site.
County personnel will also be required if the Growl test is conducted remotely from the control center. Additionally, during this test, normally conducted locally at the siren site, the mechanical counter recording the number of silent tests will be confirmed.
The annual full cycle test will be conducted during the formal preparedness exercise and will be a cooperative effort of all involved.
Preventive and corrective maintenance for the siren system will be provided by Duke Power Company personnel.
Optionally, the tone encoders at the county control centers may be maintained as part of the transmitter equipment by county contracted personnel.
8
SYSTEM TESTING AND MAINTENANCE TABLE 8.1 TEST FUNCTIONS TESTED PROCEDURE SCHEDULE 1.
SILENT Transmitter, tone encoder, receiver /
Activate tone encoder and Every two weeks, log decoder, and mechanical counter.
enter " Cancel" code, entry.
depress "Page" button, deactivate tone encoder once LED display decimal point goes out (approxi-mately 6-10 seconds).
2.
GROWL All system components except 3 Activate locally at each Quarterly and during PM.
minute timer, transmitter, and siren site using test encoder.
transmitter / encoder.
Manually cancel within a few seconds after activation.
3.
FULL CYCLE All components except " Cancel" Activate tone encoder and Annually during formal tone and mechanical counter.
enter " Alert" code, depress exercise.
"Page" button to send, wait until decimal point goes out, deactivate encoder.
4.
PM All components.
Per manufacturers Annually.
(Preventative instructions.
Maintenance).
EL40101Y