i e
)
AFFIDAVIT OF JAMES A. MACDONALD ON CCCNH-7 AND NH-9 JAMES A. MACDONALD, being on oath, deposes and says as follows:
1.
I am Manager of the Radiological Protection Group, employed by Yankee Atomic Electric Company. My professional qualifications appear in the Operating License Application (FSAR Chapter 13).
2.
The contention has no basis for the reasons given below.
General Design Criterion 63 requires monitoring of the spent fuel storage area to detect excessive radiation levels and to initiate appropriate safety actions.
As noted in Table 12.3-13 of the FSAR, the spent fuel storage area is provided with area monitors. The normal monitor has a range of 10-1 to 104 mR/hr. The accident monitor (Amendment 48) has a range of 10-2 to 104 R/hr.
Additionally, the Fuel Storage Building exhaust monitor (FSAR Section 12.3.4.2.4.(b)) is located in the Fuel Storage Building ventilation exhaust duct downstream of the fans. This detector measures the gross activity vented from the Fuel Storage Building to the plant vent.
Indication and alarm is available locally and in the main Control Room.
The effluent is monitored again at the plant vent.
General design Criterion 64 requires monitoring of the reactor containment atmosphere, spaces containing components for recirculation of loss-of-coolant accident fluids, effluent discharge paths and the plant environs for radioactivity.
Monitoring of process and effluent streams is discussed extensively in Section 11.5 of the FSAR.
Section 12.3 presents a detailed description of the airborne radioactivity monitors including the containment atmosphere monitors as well as the plant vent.
In Applicant's letter to the NRC, dated February 12, 1902, commitments were made concerning the requirements of NUREG-0737. The plant vent monitors have provisions for monitoring up to 105 uCi/cm. There are 3
also provisions for taking samples of particulates and iodines from the vent. The ster.m lines are monitored (Amendment 44) for releases of noble gas through the safety valves in the event of a tube rupture accident.
The RHR vault area and other selected PAB areas are monitored by detectors 4
with an upper range of 10 R/hr (Amendment 48). These detectors ensure adequate monitoring of spaces containing recirculated loss-of-coolant accident fluids.
The Seabrook Station Environmental Report in Sections 6.1.5 and 6.2.1 presents details of the environmental radiological monitoring program.
Section 6.2 of the Seabrook Station Emergency Plan presents information concerning assessment capabilities including provisions for off-site nonitoring in the event of an accident.
8302100142 830211 PDR ADOCK 05000443 0
Finally, the design of the process and effluent Radiological Monitoring b
Instrumentation and Sampling Systems meets the requirements of NUREG-0800, Section 11.5 because this document serves as a reference for the review of the entire RDMS specification by YNSD.
Based on the above, I feel there is no issue relative to CCCNH-7 or NH-9 on which factual hearings are warranted.
fMN h Y/
/JYd Ja s A. MacDonald COMMONWEALTH OF MASSACHUSETTS Middlesex, ss February 11, 1983 Then appeared before me the above suscribed James A. MacDonald and made oath that he was the author of the foregoing affidavit and the statements set forth therein are true to the best of his knowledge.
A A $ h % b 4-Allen
'6dre, Jr[/ Notary Public My Co ion Expires August 5, 1988
6 CERTIFICATE OF SERVICE I, Thomas G.
- Dignan, Jr.,
one of the attorneys for the Applicants herein, hereby certify that on February 11, 1983, I made service of the within " Applicants' Fifth Motion for Summary Disposition (Contentions NH-9 and CCCNH-7)" by mailing copies thereof, postage prepaid, to:
Helen Hoyt, Chairperson Rep. Beverly Hollingworth Atomic Safety and Licensing Coastal Chamber of Commerce Board Panel 209 Winnacunnet Road U.S. Nuclear Regulatory Commission Hampton, NH 03842 Washington, DC 20555 Dr. Emmeth A. Luebke William S.
Jordan, III, Esquire Atomic Safety and Licensing Harmon & Weiss Board Panel 1725 I Street, N.W.
U.S.
Nuclear Regulatory Commission Suite 506 Washington, DC 20555 Washington, DC 20006 Dr. Jerry Harbour E.
Tupper Kinder, Esquire Atomic Safety and Licensing Assistant Attorney General Board Panel Office of the Attorney General U.S.
Nuclear Regulatory Commission 208 State House Annex Washington, DC 20555 Concord, NH 03301 Atomic Safety and Licensing Roy P.
- Lessy, Jr.,
Esquire Board Panel Office of the Executive Legal U.S.
Nuclear Regulatory Commission Director Washington, DC 20555 U.S.
Nuclear Regulatory Commission Washington, DC 20555 l
Atomic Safety and Licensing Appeal Robert A.
Backus, Esquire 1
l Board Panel 116 Lowell Street j
U.S. Nuclear Regulatory Commission P.O.
Box 516 l
Washington, DC 20555 Manchester, NH 03105 l
1._. - -
Philip Ahrens, Esquire Edward J. McDermott, Esquire Assistant Attorney General Sanders and McDermott Department of the Attorney Professional Association General 408 Lafayette Road Augusta, ME 04333 Hampton, NH 03842 David L.
Lewis Jo Ann Shotwell, Esquire Atomic Safety and Licensing Assistant Attorney General Board Panel Environmental Protection Bureau U.S. Nucleat Regulatory Commission Department of the Attorney General Rm. E/W-439 One Ashburton Place, 19th Floor Washington, DC 20555 Boston, MA 02108 Mr. John B.
Tanzer Ms. Olive L. Tash Designated Representative of Designated Representative of the Town of Hampton the Town of Brentwood 5 Morningside Drive R.F.D.
1, Dalton Road Hampton, NH 03842 Brentwood, NH 03833 Roberta C.
Pevear Edward F. Meany Designated Representative of Designated Representative of the Town of Hampton Falls the Town of Rye Drinkwater Road 155 Washington Road Hampton Falls, NH 03844 Rye, NH 03870 Mrs. Sandra Gavutis Designated Representative of the Town of Kensington RFD 1 East Kingston, NH 03827
,,r
}C fpy9 -
~
Thomas G. tignan> M