l m

1671 Worcesser Rood Fromingham, Mossochusetts 01701 m W W h We (617).s72 3100 February 11, 1983 SBN-463 T.F. B7.1.2 United States Nuclear Regulatory Commission Washington, D. C. 20555 Attention:

Mr. George W. Knighton, Chief Licensing Branch No. 3 Division of Licensing

References:

(a) Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444

Subject:

Open Item Response:

(SRP 10.2.3; Materials Engineering Branch)

Dear Sir:

In response to the open item regarding the Seabrook turbine inspection frequency, we commit to one of the following conditions:

1)

Adopt a turbine maintenance program, with schedules and procedures recommended by the manufacturer based on turbine missile generation probability and approved by the NRC, within three years of the issuance of the OL, or 2)

Perform a turbine inspection prior to power escalation subsequent to completion of the second refueling outage. The results of this inspection will serve as the basis for defining a long term turbine maintenance program to be approved by the NRC.

We plan to comply with the guidance of SRP 10.2 until the time that we can provide an acceptable technical justification for an exception.

The above commitment will be incorporated in OL Application Amendment 49.

Very truly yours, 8302170366 830211 YANKEE ATOMIC ELECTRIC COMPANY PDR ADOCK 05000443 M

G PDR P

l J. DeVincentis Project Manager ALL/fsf cc: Atomic Safety and Licensing Board Service List 1000 Elm St.. P.O. Box 330. Monchester. NH O3105. Telephone (603) o69-4000. TWX 7102207595

4 ASLB SERVICE LIST Philip Ahrens, Esquire Assistant Attorney General Department of the Attorney General Augusta, ME 04333 Representative Beverly Hollingworth Coastal Chamber of Commerce 209 Winnacunnet Road Hampton, NH 03842 William S. Jordan, III, Esquire Harmon & Weiss 1725 I Street, N.W.

Suite 506 Washington, DC 20006 E. Tupper Kinder, Esquire Assistant Attorney General Office of the Attorney General 208 State House Annex Concord, NH 03301 Robert A. Backus, Esquire 116 Lowell Street P.O. Box 516 Manchester, NH 03105 Edward J. McDermott, Esquire Sanders and McDermott Professional Association 408 Lafayette Road Hampton, NH 03842 Jo Ann Shotwell, Esquire Assistant Attorney Gen'.al Environmental Protect 1an Bureau Department of the Attorney General One Ashburton Place, 19th Flcor Boston, Me 02108

.