Text
.
PUBLIC SERVICE INDIANA S. W. Shields senior vice President -
Januarv 2.6, 1983 Nuclear Division S82-23' SVP-0037-83 Mr. Jarnes G. Keppler, Docket Nos.: STN 50-546 Regional Administrator STN 50-547 U. S. Nuclear Regulatory Commission Constcuction Permit Nos.:
Region III CPPR - 170 799 Roosevelt Road CPPR - 171 Glen Ellyn, Illinois 60137 Marble Hill Nuclear Generating Station - Units 1 and 2
Dear Mr. Keppler:
On October 7, 1982, Mr. T. D. Geib of Public Service Company of Indiana, Inc. (PSI) notified your office of a potentially reportable item as required by 10 CFR 50.55(c). During the installation of the Unit 2 containment polar crane three welds between the end tie beam flange and the bottom p' ate, which is bolted to the saddle beam, had visible cracks. These cracks had the potential of adversely affecting the structural integrity of the crane. Therefore, the three cracked j
welds were excavated and magnetic particle testing was performed on the excavated a eas to assure soundness of the base material.
No further crack propagation was detected. The areas were then rewelded and the welds found acceptable. There was one additional weld of similar configuration. Magnetic particle testing was performed on this weld and test results verified the weld to be acceptable.
This letter is intended to fulfill the requirements of a final report as defined in 10 CFR 50.55(e). If you have any questions regarding this matter, please contact me at your convenience.
Sincerel
(.
8302040351 830126 S. W. Shields PDR ADOCK 05000546 G
'EX7 SWS/LGY/bak
'JAN 2 8 1983 P. O. Box 190, New Washington, Indiana 47162 812. 289.1000
.__.-_m_.
.m
.. - _ -. = -
m..
.. _. ~.
m 4
4 1
SEMVICE INDIANA j.
Letter:
J. G. Keppler ;
S82-23 l.
SVP-0007-83 i
4' I
i
.cc: Director of Inspection and Enforcement j
U. S. Nuclear Regulatory Commission 1
Washington, D. C.
20555 J. E. Konklia J. J. Harrison t
1 I.
{
f i
4 1
a
'j..
i 1
i j
f i
I i
l h
j.
1 3
1
['
t j
-....