ML20070M514

From kanterella
Jump to navigation Jump to search
Forwards Revised FSAR Section 3.9(B).2,in Response to Open Item Re Steady State & Operating Transient Vibration.Revised Pages Will Be Included in OL Application,Amend 48
ML20070M514
Person / Time
Site: Seabrook  
Issue date: 01/21/1983
From: Devincentis J
PUBLIC SERVICE CO. OF NEW HAMPSHIRE, YANKEE ATOMIC ELECTRIC CO.
To: Knighton G
Office of Nuclear Reactor Regulation
References
I.F.B7.1.2, NUDOCS 8301250229
Download: ML20070M514 (4)


Text

e SEABROOK STATION Enginsedne ONies:

1671 Worcester Rood Frondnehom, Mossochusetts 01701 PM W W h We (617) - 872 - 8100 January 21, 1983 SBN-426 T.F. B7.1.2 United States Nuclear Regulatory Commission Washington, D. C. 20555 Attention:

Mr. George W. Knighton, Chief Licensing Branch No. 3 Division of Licensing

Reference:

(a)

Construction Permits CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444

Subject:

Open Item Response (SRP 3.9.2; Mechanical Engineering Branch)

Dear Sir:

In response to the open item regarding steady state and operating transient vibration, we have revised FSAR Section 3.9(B).2 (FSAR Pages 3.9(B)-9 and 3.9(B)-10) as indicated on the attached annotated FSAR pages f

which will be included in OL Application Amendment 48.

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY

)

p J. DeVincentis Project Manager ALL/fsf ec: Atomic Safety and Licensing Board Service List oOf F 8301250229 830121 PDR ADOCK 05000443

'A PDR 1000 Elm St., P.O. Box 330. Manchester. NH 03105 + Telephone (603) 669-4000. TWX 7102207595

WELININARY SB 1 &'2 i

FSAR JAN 121983 (d) Operability and accuracy of instruments connected to piping.

5.

For steady-state vibration, the piping break stress (sero to peak) due to vibration only (neglecting pressure) will not exceed /J,gso psi for austenitic stainless steel and 7,750; poi for carbon and low alloy steels. These limits are below the piping material fatigue endurance limits as defined in 6

the design fatigue curves in Appendix I of ASME code for 10 cycles.

48 b.

Thermal Expansion During hot functional testin'g, the temperature of the reactor coolant and main steam piping will be raised to the operating temperature in increments of 1000F.

At selected temperatures, the thermal expansion of the piping will be checked at predetermined points. If thermal motion is not as predicted, the support system will be examined to verify correct function or to locate points of binding of restraints. If binding is found, the restraints will be adjusted to eliminate the un-acceptable condition or reanalysed to verify that the existing condition is acceptable.

If the support system is found to be functioning properly, but thermal expansion measurements vary from predicted values by more than a reasonable tolarence, then the analysis will be reviewed to,

explain the anomaly.

j Reasot.able tolerances, for the purpose of these tests, are as follows:

f 1.

For expected motions of 1/8 inch or less, no measurements are l

anticipated. In this case a tolerance of 11/8 inch is acceptable.

I i

l 2.

For expected motions larger than 1/8 inch but less than 2 inches, a tolerance of 150% is acceptable.

l 3.

For expected motions greater than 2 inches, a tolerance of 1 25% of the expected motion is acceptable.

c.

Dynamic Ef fects During the preoperational test and initial startup programs, the pumps will be started and stopped and valves will be stroked to verify proper operation. The effects of the transient vibrations and shocks resulting from these operations will be visually observed to verify that no excessive motion of piping or equipment results.

If excessive motions are observed as a result of these operations, the support systems will be adjusted to eliminate the unacceptable motion. In cases where sequence of operations or operating procedures 3.9(B)-9

ELIN I N A W SB 1 & 2 FSAR JAN 121983 are found to 'cause unacceptable conditions, procedures will be changed to eliminate the unacceptable conditions.

For operating transient vibration, the piping bending stress, (zero to peak) due to the operating transient vibration, will be correlated with the calculated stress level from the piping stress report, in order to ensure that the calculated total primary stress level is maintained within acceptable code levels. Where testing results indicate unacceptable levels, action will be taken to reduce or eliminate the effect of the operating transient vibration.

A6 The details of the piping. vibration, thermal expansion and dynamic ef fects testing will be incorporated into the individual test proce-dures for conducting these tests, as abstracted in Chapter 14.

Specific information and data will be generated for the preparation of piping tests. This will include the different flow modes, identi-fication of the selected locations for visual inspections and measure-ments, the acceptance criteria, and the possible corrective actions if excessive vibration occurs.

3.9(B).2.2 Seismic Qualification Testing of Safety-Related Mechanical Equipment Seismic Category I safety-related mechanical equipment has been designed to withstand the combined normal operating accident loads concurrent with the effects of the Safe Shutdown Earthquake (SSE) or the Operating Basis Earthquake (OBE). Verification of the adequacy of the equipment to withstand theae combined loads has been demonstrated.by analysis, by testing, or a comu stion of analysis and testing. Selection of the method of qualification was determined i

by the type, size, shape and complexity of the equipment being considered.

Operability of active Class 1, 2 or 3 valves, active Class 2 and 3 pumps, and their vital auxiliary equipment has been demonstrated by the combination of analysis and testing. Results of the qualification tests are given in Subsection 3.9(B).3.2.

The seismic qualification procedures used for the operability verification of other active mechanical equipment are similar to the pro:edures described in Subsection 3.9(B).3.2 for pumps and valves.

I For the mechanical equipment which is mechanically or structurally too complex, i.e., the seismic response cannot be adequately predicted analytically, testing procedures similar to those described in Section 3.10 were used to demonstrate the equipment operability and adequacy.

ne structural and functional integrity of non-active seismic Category I l

mechanical equipment has been demonstrated by one of the following two methods:

By analytical methods, to satisfy the stress criteria applicable a.

to that specific piece of equipment.

b.

By seismic testing, to show that the equipment retains its structural and functional integrity under the simulated test environment.

3.9(B)-10 l

l m _ _. _

m

7-.-.

ASLB SERVICE LIST Philip Ahrens, Esquire Assistant Attorney General Department of the Attorney General Augusta, ME 04333 Representative Beverly Hollingworth Coastal Chamber of Commerce 209 Winnacunnet Road Hampton, NH 03842 William S. Jordan, III, Esquire Harmon & Weiss 1725 I Street, N.W.

Suite 506 Washington, DC 20006 E. Tupper Kinder, Esquire Assistant Attorney General Office of the Attorney General 208 State House Annex concord, NH 03301 Robert A. Backus, Esquire 116 Lowell Street P.O. Box 516 Manchester, NH 03105 Edward J. McDermott, Esquire Sanders and McDermott Professional Association 408 Lafayette Road Hampton, NH 03842 Jo Ann Shotwell, Esquire Assistant Attorney General Environmental Protection dureau Department of the Attorney General One Ashburton Place, 19th Floor l

Boston, MA 02108 i

e e

+

une.ewg

%.g 9 -

g-e--

h -eu w sw% w +ge

=i.e***-+

=

r

  • *-