ATTACHMENT 2 LIMERICK GENERATING STATION UNIT 1 AND UNIT 2 DOCKET NOs.
50-352 50-353 LICENSE NOs.
NPF-39 NPF-85 TECHNICAL SPECIFICATIONS CHANGE REQUEST NO. 94-11-0 AFFECTED PAGES UNIT 1 UNIT 2 3/4319 3/4 3-19 3/4 3-20 3/4 3-20 9407250216 940720 D:1 ADOCK 0500 "2
TABLE 3.3.2-2 (Continued)
ISOLATION ACTUATION INSTRUMENTATION SETPOINTS r-E ALLOWABLE 9
TRIP FUNCTION TRIP SETPOINT VALUE F;
7 3.
REACTOR WATER CLEANUP SYSTEM ISOLATION E
a.
RWCS a Flow - High 5 54.9 gpm s 65.2 gpm b.
RWCS Area Temperature - High s 135 F or 122*F**
s 145"F or 130 F**
c.
RWCS Area Ventilation a Temperature - High 5 32 F s 40 F d.
SLCS Initiation N.A.
N.A.
e.
Low, Low, - Level 2 2 -38 inches
- 2 -45 inches y
f.
Manual Initiation N.A.
N.A.
4.
HIGH PRESSURE COOLANT INJECTION SYSTEM ISOLATION a.
HPCI Steam Line a Pressure - High 5 343" H O s 358" H O 2
2 b.
HPCI Steam Supply Pressure - Low 2 100 psig 2 90 psig l
c.
HPCI Turbine Exhaust Diaphragm Pressure - High s 10 psig s 20 psig d.
HPCI Equipment Room Temperature - High 225 F 2 218*F, s 247*F l
e.
HPCI Equipment Room a Temperature - High
$ 126*F s 130.5*F l
f.
HPCI Pipe Routing Area l
Temperature - High 175 F 2 165*F, s 200 F g.
Manual Initiation N.A.
N.A.
h.
HPCI Steam Line a Pressure - Timer 3 s r s 12.5 seconds 2.5 s r s 13 seconds l
TABLE 3.3.2-2 (Continued)
ISOLATION ACTUATION INSTRUMENTATION SETPOINTS E
~
ALLOWABLE g
- q TRIP FUNCTION TRIP SETPOINT VALUE x
5.
REACTOR CORE ISOLATION COOLING SYSTEM ISOLATION E
a.
RCIC Steam Line A Pressure - High s 213" H O s 223" H,0 2
b.
RCIC Steam Supply Pressure - Low 2 64.5 psig 2 56.5 psig c.
RCIC Turbine Exhaust Diaphragm Pressure - High s 10.0 psig s 20.0 psig d.
RCIC Equipment Room Temperature - High 205 F 2 198 F, 5 227*F s"
e.
RCIC Equipment Room A Temperature - High s 109"F s 113.5*F l
w h
f.
RCIC Pipe Routing Area Temperature - High 175 F 2 165 F, s 200*F g.
Manual Initiation N.A.
N.A.
h.
RCIC Steam Line A Pressure Timer 3 5 r s 12.5 seconds 2.5 s r 513 seconds
TABLE 3.3.2-2 (Continued)
ISOLATION ACTUATION INSTRUMENTATION SETPOINTS C
ALLOWABLE h
TRIP FUNCTION TRIP SETPOINT VALUE 3.
REACTOR WATER CLEANUP SYSTEM ISOLATION
_h a.
RWCS A Flow - High s 54.9 gpm s 65.2 gpm
[
b.
RWCS Area Temperature - High s 135 F or 122*F**
s 145*F or 130*F**
c.
RWCS Area Ventilation a Temperature - High s 32*F s 40 F d.
SLCS Initiation N.A.
N.A.
e.
Low, Low, - Level 2 2 -38 inches
- 2 -45 inches f.
Manual Initiation N.A.
N.A.
g y
4.
HIGH PRESSURE COOLANT INJECTION SYSTEM ISOLATION a.
HPCI Steam Line a Pressure - High s 343" H O s 358" H O 2
2 b.
HPCI Steam Supply Pressure - Low 2 100 psig 2 90 psig c.
HPCI Turbine Exhaust Diaphragm Pressure - High s 10 psig 5 20 psig d.
HPCI Equipment Room Tengerature - High 225 F 2 218 F, s 247"F e.
HPCI Equipment Room a Temperature - High s 126 F s 130.5 F f.
HPCI Pipe Routing Area Temperature - High 175 F 2 165*F, s 200*F g.
Hanual Initiation N.A.
N.A.
h.
HPCI Steam Line a Pressure - Timer 3 s r s 12.5 seconds 2.5 s r s 13 seconds
TABLE 3.3.2-2 (Continued)
ISOLATION ACTUATION INSTRUMENTATION SETPOINTS r.
EE 59 ALL0h'ABLE TRIP FUNCTION TRIP SETPOINT VALUE gj 5.
REACTOR CORE ISOLATION COOLING SYSTEM ISOLATION E
- q a.
RCIC Steam Line a Pressure - High s 213" H,0 s 223" H O 2
n3 b.
RCIC Steam Supply Pressure - Low 2 64.5 psig 2 56.5 psig i
c.
RCIC Turbine Exhaust Diaphragm Pressure - High s 10.0 psig s 20.0 psig d.
RCIC Equipment Room Temperature - High 215*F 2 198*F, s 227"E ff e.
RCIC Equipment Room i
A Temperature - High s 109 F s 113.5 F l
l i'
S' f.
RCIC Pipe Routing Area Temperature - High 175 F 2 165 F, s 200*F g.
Manual Initiation N.A.
N.A.
h.
RCIC Steam Line a fressure Timer 3 s r s 12.5 seconds 2.5 s r s 13 seconds L