Final Deficiency Rept Re Seat Leakage in Asco Solenoid Valves Mounted on Posi-Seal Intl Butterfly Valves.Initially Reported on 821103.Posi-Seal Intl Supplied Relubrication Kits to Correct Problem
ML20070F923
Person / Time
Site: Seabrook  
Issue date: 12/08/1982
From: Devincentis J
PUBLIC SERVICE CO. OF NEW HAMPSHIRE, YANKEE ATOMIC ELECTRIC CO.
To: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
10CFR-050.55E, 10CFR-50.55E, SBN-404, NUDOCS 8212210287
Download: ML20070F923 (3)


Text

o PUE3LIC SERVICE SE M N S M M Enginoming ONice:

Companyof NewHempehre 1671 Worcester Road Framinoham, Massochusetts 01701 (617). 872 - 8100 December 8, 1982 SBN-404 T.F. Q2.2.2 Unit 9d States Nuclear Regulatory Cocunission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:

Mr. Richard W. Starostecki, Director Division of Resident and Project Inspectior Re ferences :

(a) Construction Permit CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) Telecon of November 3,1982, A. L. Ingendre (YAEC) to E.

Brunner (NRC Region I)

Subject:

Final 10CFR50.55(e) Report; Posi-Seal International Butterfly Valve /ASCO Solenoid Valve

Dear Sir:

On November 3, 1982, a potentially reportable 10CFR50 55(e) item was reported [ Refer e. ace (b)] regarding the potential for seat leakage in ASCO solenoid valves which are mounted on Posi-Seal International butterfly valves.

It has been determined that this item is reportable under 10CFR50.55(e).

We following information is provided per 10CFR50.55(e)(3) and is considered to be the final report on this item.

Description of Deficiency The deficiency involved ASCO solenoid valves which may experience excessive seat leakage due to improper lubricant for oil f ree air.

We ASCO solenoid valves are mounted on 26 Posi-Seal International butterfly valves which have been purchased for Seabrook Station. Nine valves have been installed but have yet to be cycled. Posi-Seal notified the NRC Office of Inspection and Enforcement of this deficiency via a Noncompliance Notification Report, dated October 13, 1982.

Analysis of Safety Implications The ASCO Report indicates that incomplete shifting of the valves in seating may occur af ter a minimum life of 1000 cycles. With proper lubrication, the valves would be suitable for 40,000 cycles. UEEC specifications require 250 cycles per year or 10,000 cycles over a 40 year period. The valves in question have not been cycled. Af ter installation and in operation the valves would be suitable for four (4) years operation even without relubrication. Since they have been relubricated, the valves will be suitable for 40 years design life.

8212210287 821200 PDR ADOCK 05000443 PDR S

gg

+

Unitid Stntcs NuclGOr Regulntory Comunic2itn December 8, 1982 Attention:

Mr. Richard W. Starosrecki Page 2 Corrective Action Taken Lubrication kits as defined in ASCO Service Bulletin, dated May 21, 1982 have been supplied to the field to correct the problem. Future occurrences of the foregoing deficiency should not exist since the manufacturer, Posi-Seal International, Inc. notified both UIEC and the NRC of this problem and provided the correct relubrication kits needed to complete the corrective action required.

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY 8

J. DeVincentis Project Manager ALL/fs f cc: Atomic Safety and Licensing Board

a..

o e

ASLB SERVICE LIST Philip Ahrens, Esquire Assistant Attorney General Department of the Attorney General Augusta, ME 04333 Representative Beverly Hollingworth Coastal Chamber of Commerce 209 Winnacunnet Road Hampton, NH 03842 William S. Jordan, III, Esquire Harmon & Weiss 1725 I Street, N.W.

Suite 506 Washington, DC 20006 E. Tupper Kinder, Esquire Assistant Attorney General Office of the Attorney General 208 State House Annex Concord, NH 03301 Robert A. Backus, Esquire 116 Lowell Street P.O. Box 516 Manchester, NH 03105 Edward J. McDermott, Esquire Sanders and McDermott Professional Association 408 Lafayette Road Hampton, NH 03842 Jo Ann Shotwell, Esquire Assistant Attorney General Environmental Protection Bureau Department of the Attorney General One Ashburton Place, 19th Floor Boston, MA 02108 i