A'"

NuMOHAWK Y NIAGARA MMP t;Mfc NIAGARA MOHAWK POWER CORPORATION /300 ERIE BOULEVARD WEST. SYRACUSE, N Y.13202/ TELEPHONE (315) 474-1511 November 19, 1982 t

blt. Pichard W. Starostecki, Director Division of Project and Resident Programs United States Nuclear Regulatory Consission Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 RE: Docket No. 50-220 Inopection Report 82-17 Dear Ali. Starostechi This refers to the routine safety inspection conducted by bit. S. Hudson of your cffice on September 1-October 1,1982 d the Mine blite Point Nuclear Station Unit M1.

In regard to the seven outstanding 1980 circulars, a further review of our records has revealed that three of.them had been addressed at the time of the inspection.

IEC 80-03, " Protection From Toxic Gas Hazards", had been addressed and ciosed out by a study dated 12/31/80.

1EC 80-09, " Plant Internal Commwtication Systems", tato addressed and closed out on 2/12/82.

IEC 80-18, "10 CFR 50.59 Safety Evaluations" teas addressed and closed out on 1/4/82 Three of the rema.ining four outstanding circulars have been addressed and closed out subsequent to the Inspection.

IEC 80-08, "RBS Response Time" tazs addressed and closed out on 11/8/82.

IEC 80-10, "Faiture to Maintain Environmental Qualification of Equipment", tais addressed and closed out on 11/15/82.

l l

8212150213 821210 PDR ADOCK 05000220 G

PDR

1 Page 2 IE 80-17 IEC 80-14, " Radioactive Contamina. tion of Plant Dcmineralized Water System", was addressed and closed out on 11/8/82.

The remaining Circular, IEC 80-22, "Confiwation of Employee Qualifi-cations", will be addressed and closed out by 1/1/83.

Very truly yours

/

./

h W4 r 4r Thomas E. Lempges Vice President, Nuclear Generation TLL/jm l

1