ML20070A716

From kanterella
Jump to navigation Jump to search
Informs That Nj Dept of Environ Protection & Energy Bureau of Nuclear Engineering Reviewed Util Analysis Concerning Determination of NSHC of TS Change Request 213 Submitted by Re RPV Testing - EMRV Bypass & Has No Comments
ML20070A716
Person / Time
Site: Oyster Creek
Issue date: 06/21/1994
From: Tosch K
NEW JERSEY, STATE OF
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9406290134
Download: ML20070A716 (2)


Text

_

Commissioner and Analytical Programs Radiation Protection Programs Bureau of Nuclear Engineering CN 415 Trenton, New Jersey 08625-0415 Tel (609) 987-2032 Fax (609) 987-6354 June 21, 1994 U.S.

Nuclear Regulatory Commission Document Control Room Washington, D.C.

20555 Ladies and Gentlemen:

Subject:

Oyster Creek Nuclear Generating Station (OCNGS)

Docket No. 50-219 Technical Specification Change Request (TSCR No 213)

Reactor Pressure Vessel Testing Electromatic Relief Valve (EMRV) Bypass By letter dated April 19, 1994, GPUN Corporation submitted to the U.S.

Nuclear Regulatory Commission (NRC)

Technical Specification Change Request No. 213, seeking approval to update and clarify Technical Specification (TS) 3.4.B.1 to make it consistent with existing Specifications 1.39 and 4.3.D, per ASME Code Section XI, Article 5000 requirements.

The language change making reference to current TSs (instead of direct reference to the applicable sections of the aforementioned ASME Code), seeks to clarify that the five EMRV's pressure relief function may be inoperable or bypassed during hydrotests (per ASME Code) following outages or major repairs, without impacting on safety considerations.

The licensee states that since the EMRV's pressure actuation setpoint is lower than the pressure of the hydrotest, bypassing is necessary in order to avoid inadvertent actuation of the relief function.

GPUN further justifies the request by stating that inoperable EMRVs will not impact on any safety function necessary during the conditions of the hydrotest, because the design over-pressure protection function is carried out not by the EMRVs but by nine over-pressure protection safety valves.

The New Jersey Department of Environmental Protection and 4

Energy's Bureau of Nuclear Engineering (BNE) has reviewed GPUN's

{

analysis concerning the determination of no significant hazards consideration of TSCR-213 and has no comments.

j 0

9406290134 940621

      1. " Y N EEu PDR ADOCK 05000219 P

PDR

A. 5 s

0

. If you have any questions, please contact suren Singh at (609) 987-2039 or Rich Pinney at (609) 987-2086.

Sincerely, Tf' C4 Kent Tosch, Manager Bureau of Nuclear Engineering c:

A.

McMahon, Acting Assistant Director RPP -- NJ DEPE D.

Chawaga, State Liaison, Region I -- US NRC L.

Briggs, Senior Resident Inspector OCNGS -- US NRC M.

Laggart, Licensing Manager -- GPUN D

.