ML20070A014
| ML20070A014 | |
| Person / Time | |
|---|---|
| Site: | Catawba |
| Issue date: | 06/20/1994 |
| From: | Tuckman M DUKE POWER CO. |
| To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
| References | |
| GL-92-01, GL-92-1, TAC-M83448, TAC-M83449, NUDOCS 9406280128 | |
| Download: ML20070A014 (2) | |
Text
ll l
c r
DukeIbwer Company M S TLcxw P0 Bax l'/4 Senior Mce President Charlotte, NC28201-1006 Nuclear Generation (704)382-22000ffice (704)382-4360 Fax DUKEPOWER June 20, 1994 U.
S.
Nuclear Regulatory Commission Washington, D.
C.
20555 Attention: Document Control Desk i
Subject:
Catawba Nuclear Station, Units 1 and 2 Docket Numbers 50-413 and -414 Generic Letter 92-01, Revision 1; Verification of Data Base Entries (TAC Nos. M83448 and M83449)
By letter dated May 25, 1994, the NRC forwarded a set of data to be used in the Reactor Vessel Integrity Database, and requested that Duke review the data for accuracy.
In reviewing the data for Catawba, some erroneous data were discovered.
For Catawba Unit 1, Lower Shell Forging 04, Heat No. Ident. 527708, the %Cu value should be 0.05. For Circ. Weld WOS, Heat No. Ident.
895075, the %Ni valun should be 0.72.
The reference for both values is WCAP-13763 (Table 1), August 1993, which was transmitted i
to the NRC by letter from D.
L.
Rehn to Document Control Desk, dated August 12, 1993.
For Catawba Unit 2,
ID Neut. Fluence at EOL value should be 2.46E19.
(Reference WCAP-13875, Table 6-15,
- February, 1994, transmitted by letter, D.
L.
Rehn to Document Control Desk, March 2,
1994.)
This will change the value of 1/4T fluence for upper shelf energy.
If you have any questions about these data, please call Scott Gewehr at (704) 382-7581.
Very tru
- yours,
% s.
) w6vw.
M.
S.
Tuckman nt
(,
c
.U 4 4 PDR I
ww:<mvn m
e I
U.
S.. Nuclear Regulatory Commision J,une 20, 1994 Page 2 cc:
Mr. R.
E.
Martin, Project Manager Office of Nuclear Reactor Regulation U.
S.
Nuclear Regulatory Commission Mail Stop 14H25, OWFN Washington, D.
C.
20555
)
Mr.
S.
D.
Ebneter, Regional Administrator U.S.
Nuclear Regulatory Commission - Region II 101 Marietta Street, NW - Suite 2900 Atlanta, Georgia 30323
- - -