APPLICANTS' BRIEF REGARDING CONSIDERATION OF THERMAL STRESSES IN DESIGN OF PIPE SUPPORTS I.
INTRODUCTION In its conference call of April 7, 1983, the Licensing Board in the captioned proceeding requested that the parties submit briefs regarding the applicable NRC requirements and guidance governing the consideration of LOCA conditions in the. design of pipe supports.
The Board stated that the brief should provide a
" discussion of the relationship between the different regulatory materials, including the design criteria, the standard review plan, staff guidance, staff practice, and applicable industry codes" on this topic. 1 Speci fically, the Board inquired as to
,Mg the legal basis for the conclusion that loads in support Wet
' if Ln t
o 1
Tr. 43.
(Transcript references are to the transcript of the hg April 7, 1983, Conference call unless otherwise noted.)
88 l Jae
$.5 lDs
anchorages and stresses in support steel due to differential thermal expansion in pipe support members under LOCA conditions nec3 'not be addressed in the design of individual pipe supports.2
-A.
Background
The issue of whether stresses resulting from differential
-thermal expansion of pipe supports induced by elevated temperatures within containment following a LOCA need be considered in the design of those supports arose in this proceeding as a result of allegations made by CASE witnesses 3
Walsh.and Doyle.
Applicants responded to these allegations with-detailed testimony 4 at the September, 1982 hearing session by a panel of experts highly qualified in the design of piping and support systems. for nuclear power reactors and eni~nent in the field of.American Society of Mechanical Engineers ("ASME") Code requirements.
In their testimony,' Applicants' witnesses demonstrated that the ASME Code did not require consideration of such LOCA-induced stresses in the design of pipe supports and that this aspect of the Code was based on sound engineering 2
See Tr. 30-31 whereat Judge Jordan referred to I & E Report 82-26/82-14 (February 15, 1983). at pp. 18424.
3 See CASE Exhibit 669 at pp. 14-21, 36-63 and Attachment E, and Tr. 3109-3145.
4 Applicants' Exhibits 142, 142F.
n principles and judgment. 5 The NRC Staff concurs with Applicants that stresses due to differential-thermal' expansion in pipe supports under any conditions need not be considered in the design of pipe supports. 6 B.
Issue Presented It is essential at the outset to establish the precise nature and scope of the conclusions reached by the Applicants and NRC Staff regarding consideration of stresses induced by differential thermal expansion of pipe supports.
This will assure that the information necessary to respond to the Board's inquiry is presented concisely.
Accordingly, Applicants provide the following discussion.
1.
Allegations of Messrs. Walsh and Doyle.
The LOCA-induced stresses of concern to CASE witnesses Walsh and Doyle (and addressed by Applicants and the NRC Staff) are those which result from the differential expansion in'duced under LOCA ( i. e., high temperature) conditions between the support 7 and the structures to which steel in a linear-type pipe support 5
See e.g.,
Applicants' Exhibits 142 at.14-25, 142F at 3.
6 I & E Report 82-96/82-14, at 24.
7 ASME Code Paragraph NF-1213 defines a Linear-Type Support as follows:
A linear type component support is defined as
. acting under essentially a single component of direct stress.
Such elements may also be subjected to such stresses.
l o
t
-the support is attached.
Specifically, Walsh and Doyle argued that the analysis of individual supports should include.
consideration of. stresses' induced due to thermal ~ expansion of.the support under LOCA (i.e. high temperature) conditions.
These stresses arise from the restraint against expansion exerted either by rigid connections (viz., anchorages) to the surrounding structure or by the structure itself (i.e., wall-to-wall or floor-to-ceiling support members).8 In addition, Walsh and Doyle contended that the loads induced in the support anchorages themselves as a result of this differential thermal. expansion should also be calculated in the analysis of. individual supports.9 2.
Applicants'. and Staff's Conclusions Regarding the Walsh/Doyle Allegations.
In response to those allegations, Applicants' witnesses demonstrated that such thermal stresses were self-limiting because slight deformations of connections or support members would' relieve'those stresses without loss of function. 10 Applicants further demonstrated that applicable provisions of the I
i 8
Th'e Board should examine the discussion at the September 16, 1983 hearing (Tr. 5233-76) for a further explanation of the geometry involved in these supports.
9 CASE Exhibit 669 at 14-21, 36-63 and Attachment E; Tr.
3109-45, 10 See Applicants' Exhibits 142 at 21-25; 142D.
i i
._,r,..
,,,_.-,_,_.m_
5-
~.ASME Code allow individual.linsar-type pipe supports to be
[
designed (without consideration of. such secondary -(i.e., fself-
- lbniting)' stresses.ll The NRC Staff has concurred in 'these conclusions.12 In sum,' both.'the ' Applicants and the Staff have concluded that the -stresses 'in pipe supports and ' anchorages which
. result from the differential thermal expansion in a LOCA environment between the supports and-the structures to which they lare attached.need not be addressed in the design of individual F
pipe supports.
W 3
f 11 Applicants' Exhibit 142 at 14-21.
Walsh and Doyle contend
. that such secondary stresses must be considered.as primary stresses in the analysis of linear-type pipe suports.
However, as demonstrated by Appl'icants' witnesses, even
- where the ASME Code requires evaluation of secondary stresses (e.g.,
Class 1 vessels) the allowable limit is
- three. times the allowable limit for primary stress.
In contrast, in components where only linear (and not multi-
~
directional) stresses.are considered, the Code does not require evaluation of secondary stresses because the displacements are limited by virtue of limits on temperature.
Id. at 17.
12 I&E Report 82-29/82-14 at 21.
The Staff re confirmatory shear tests of the deflection / quested that load character-L istics of 1 1/2 inch Richmond inserts be conducted.
I& E i
Report 82-29/82-14 at 21.
These tests have now been i
successfully completed and their results will be provided for the record.
i t
l 9,y y4 wme-
-w
--u--g--,,e g.,
y~,y,vg--
y y9,*yig-
.,ww~
,ewy----,-ggwyn=em1 yp g
~ - - -ey-.--
-9 4,y-.
e e-v'-w+M--v--w7-es-4,wm==m vm
4
--6 3.
Scope of; Applicants' and Staf f's-Conclusions.
The Board should note that the' allegations of Walsh and Doyle, and the Applicants' and Staff's responses thereto, concern only loads or loading combinations which may be imposed on pipe supports as a result of a LOCA, as discussed above.
Those allegations do not implicate the loads on pipe supports resulting from the mechanical and dynamic forces associated with LOCA events.
Those loads and associated stresses are the subject of extensive analysis for all pipe supports. 13 Those allegations do.not implicate the stresses induced in the pipe supports as a result of the thermal expansion of piping following a LOCA.
Those stresses also are considered, 14 as are the variations in allowable stresses.which result from changes in.the temperature-sensitive pipe support material properties in a LOCA environment.15 In short, Applican'ts have considered the effects on pipe supports resulting from LOCA events, and the intervenor's allegations do not involve those considerations.
It is only 13 See discussion infra.
14 See FSAR Tables 3.9B-lC and 1D.
Applicants note that these effects are considered for Class 1, 2 and 3 supports even though' it is not considered necessary with respect to Class 2 and 3 supports.
See Regulatory Guide 1.48, p.
1.48-4, ASME Code Class 2 & 3 Piping.
15 See Regulatory Guide 1.124, and the discussion thereof, Intra at 19-21.
c
,5-7-
those stresses induced in the supports and their anchorages as a result of differential thermal expansion under LOCA conditions which are the subject of the allegations.16 Accordingly, in view of the allegations made and the carefully-defined conclusions of the Applicants and the NRC Staff, the issue before the Board is clear,.viz., LOCA-induced secondary stresses in pipe supports resulting from differential thermal expansion, and this brief addresses that issue.
Applicants believe that this inquiry-is best addressed with an examination and interpretation of applicable NRC regulations, guidance and practice which govern the consideration of those stresses.
As demonstrated below, both NRC regulations and guidance implementing the General Design Criteria provide for the utilization of applicable ASME Code provisions in the construction of pipe supports.
The Code provides that these 16 The~ record reflects that there had been extensive consideration given to the inclusion of these stresses in the analyses of pipe supports even before Walsh and Doyle presented their allegations in this proceeding.
It was concluded on the basis of interpretation of the ASME Code and the engineering judgment of experienced professional engineers that those stresses need not be addressed in the analyses of individual supports.
In addition, Applicants subsequently confirmed through case-specific analyses (received into evidence here) that the assumptions premised on the ASME Code and engineering judgment were valid.
A more detailed discussion of the record appears infra, at pp.
23-27.
,g-
,---c en
-.e,
e
. g.
. thermal expansion loads need not be calculated in the stress analysis of individual pipe supports because'they are self-limiting'and.the,refore of a secondar'y nature.
II.
APPLICABLE REGULATORY REQUIREMENTS GOVERNING CONSIDERATION OF LOCA EFFECTS A.
General Design Criteria NRC requirements governing the design of structures, systems and components bnportant to safety are the General-Design Criteria ("GDC") set forth in Appendix A to 10 C.F.R. Part 50.
The General Design Criteria establish minimum requirements for
.th'e principal design criteria for nuclear power reactors.
10 C.F.R. $50.34(a)(3)(i).
These principal design criteria must be established at the time an application for a construction permit is submitted, 10 C.F.R. $50. 34( a) (3 ) (1), and are to provide the necessary design, fabrication, construction, testing, and performance requirements for structures, systems, and components important to safety.
10 C.F.R. Part 50, Appendix A, Introduction.
Applications for operating licenses are to include a sufficient description of the structures, systems and components of the facility to permit an understanding of the system designs and their relationship to safety evaluations.
10 C.F.R. $50. 34(b) (2 ).
n..
.. -.. --.,,,--...,..--,-. ~.- -- -,-.,.-.,..-~
m 1.
4 Three General Design Criteria govern the' consideration of the effects of a.LOCA on the' structures, systems, and components important to safety, including pipe supports.
First, GDC-1
~
(quality standards and records) provides, in part, as follows:
Structures, systems, and components important to' safety shall be designed, fabricated, erected,,and tested to quality-standards commensurite with the-bnportance of the safety functions to be performed.
[10 C'F.R.
Part 50, Appendix A, GDC-1 3 GDC-1 also provides that generally recognized codes and standards
- may be used to satisfy the criterion where such are identified and evaluated to determine their applicability., adequacy, and sufficiency.
Such codes and standards are to be supplemented or modified if necessary to assure a quality product in keeping with the. required safety function.
In addition, GDC-2 (design bases for protection against natural phenomena) provides that the design bases for. structures, systems, and components' important to safety shall reflect, inter i
alia:-
appropriate combinations of the effects of normal and accident conditions with the ef fects of.
natural phenomena.
[10 CFR Part 50, Appendix'A, GDC-2.]
l f
,m=.
v.
g---..
,,,.,-,,-----------,,--,-.--,,,--,.-,,.,,,,m--,-..,,,-.y.y-.,--,-w
,--.-,,---,,,..,.,.-,,,,-w-
t j
-t These design bases are to' assure that structures, systems and components irftportant to safety can withstand such combinations of 2
effects without. loss of their. capability _to perform'their safety functions.. E10 C.F.R.- Part 50, Appendix A, GDC-2..
Finally,fGDC-4-(environmental and missile design bases)
' provides, in part, as follows:
Structures, systems, and components important-to safety shall be designed to accommodate the effects of and to be compatible with the environmental conditions associated with-normal operation, maintenance, testing, and postulated accidents, including loss-of-coolant accidents.
[10 CFR Part 50, Appendix A, GDC-4.]
'In smn, these General Design Criteria provide general requirements governing the design of structures, systems, and
' components important to safety at nuclear power reactors.
t
. Implementation of these requirements necessarily requires the t
t establishment of specific design criteria for each structure, system, and component important to safety to be utilized at the
' facility.
As discussed below, NRC regulations and guidance address the establishment of such specific criteria, including the utilization of industry codes and standards accepted by t'he L
-NRC for those purposes.
t i
.~,,__.___
_,_,,__._,___-..__.,______...__,n_______.,_..._____..,..__._____
a
~
B.
~ Utilization of the ASME Nuclear Code NRC regulations impose requirements governing, inter alia,
-the design,: fabrication and installation.of certain components of
-nuclear ~ power reactors.
Specifically, Section 50.55a(a)(2) of 10
~
C.F.R.' provides that, at-a minimum,- the particular systems and components of. pressurized water reactors shall~ meet certain requirements, - including pertinent portions of the ASME ' Boiler and Pressure-Vessel. Code..
The ASME Code is a set of Engineering
-Safety Standards written and published ~ by The American Society of Mechanical'Eng'ineers.
Section III of that Code, known as the ASME Nuclear Code ("ASME Code" or " Code"), provides rules for the design and' construction of presure vessels, piping system, pumps, valves, storage tanks, component supports and core support structures used in nuclear power plants.
The Code presents a set of minimum requirements developed to assure the integrity of. the pressure retaining equipment and related systems in a nuclear power plant.
The subsection of 10 C.F.R. 550.55a which governs the design, fabrication and installation of piping which is part of the reactor coolant pressure boundary (10 C.F.R. $50.55a(d)(3)),
provides that for facilities for which construction permits were issued on or after July 1, 1974,17 such piping:
17 The construction permits for Comanche Peak, Units 1 and 2 were issued in December, 1974.
shall meet the requirements for Class 1 components set forth in Section III
-[ footnotes omitted] of the ASME' Boiler and Pressure Vessel Code:
Provided, that the ASME Code provisions applied to the piping shaJ be no earlier than those of Winter 197z Addenda of the 1971' edition.
The design requirements of the ASME Code governing Class 1 piping.are set forth in Subsection NB of'the Code.
That subsection provides that the design of the supports for the Class 1 piping shall be accomplished in accordance with Subsection NF of the_ Code, as follows:
NB-3674 Design of Pipe Supporting Elements -
Supporting elements, including hangers, anchors, and sliding supports, shall be designed in accordance with the requirements of Subsection NF.
In addition, as will be discussed more fully below, Re~gulatory Guide 1.124 18'also provides that Class 1 linear-type component supports shall be constructed in accordance with Subsection NF.
Accordingly, both-the applicable regulations and NRC guidelines look to the ASME Code for the design of Class 1 linear-type component supports.
With respect to the design of supports.for other than Class 1 components, 10 C.F.R.-$ 50.55a(a)(1) provides that structures, systems and components:
18 Regulatory Guide 1.124, Revision 1,
" Service Limits and Loading Combinations for Class 1 Linear-Type Component Supports" (January 1978).
shall be designed to quality standards commensurate with the importance of the safety function to-be performed.
a Applicable NRC Staff guidance establishes the quality standards.
.that may be used to satisfy GDC-1 for other than the Class 1 safety-related components.- As discussed more fully below, both the applicable Regulatory Guide 19 and provisions'of the Standard
. Review Plan 2O provide that with respect to Class 2 and 3 piping, Subsections NC and ND, respectively, of the ASME Code may'be utilized as the governing quality standards.
As with subsection NB, those Subsections require design of supports in accordance with Subsection NF.21 In sum, for each of Class 1, 2 and 3 supports, both the applicable NRC regulations and. guidance look to the ASME Code for construction 22 standards.23 19 Regulatory Guide 1.26, Revision 3 " Quality Group Classifications and Standards for Water, Steam, and Radioactive-Waste'Containing Components of Nuclear Power Plants" (February 1976).
20 S RP 3. 2. 2,
" System Quality Group Classification," Table 3.2.2-1.
i 21 See Subsections NC-3674 and ND-3674.
22 As defined in Subarticle NCA-1110 of Section III of the ASME Boiler and Pressure Vessel Code, construction is an all-inclusive term comprising materials, design, fabrication, examination, testing, inspection, and certification required in the manufacturing and installation of components.
23 The Commission has proposed to incorporate by reference into (footnote continued) l
- Q7 6
III.-
NRC GUIDANCE GOVERNING THE CONSTRUCTION OF PIPE SUPPORTS To implement NRC' regulations governing, inter alia, the
' construction.of ' component supports, the NRC Staff has issued guidance documents, primar'ily in the form of Regulatory Guides.
In addition, a description of the standards and criteria employed j
by;the'NRC in its review of applications for power reactor r
- licenses, including. the review of 'the construction of component supports,.is set-forth-in the Standard Review Plan..These i
I
~
guidance documents provide that the requirements of GDC-1, GDC-2 and GDC-4, as well as 10 CFR 550.55a, concerning the construction
- of component supports, may be satisfied by adherence to the b
. guidance in the docu.1ents.
As discussed below, that guidance i
permits the utilization of applicable ASME Code provisions-to
- determine the types of loads to be considered in the construction of supports.
i
( footnote continued from previous page)
I 10 C.F.R..550.55a other parts of the ASME Code not alrea'dy expressly incorporated.
47 Fed. Reg. 15801 (April 13,
~
1982).- -These other. parts of the ASME Code cover, inter i
alia, component supports. -47 Fed. Reg. 15802.
In proposing i
this amendment to-10 C.F.R.
50.55a, the Commission noted
'that although not expressly included in the regulation, those parts of'the ASME Code that pertain to other systems important to safety are also reviewed by the Commission staff and, if acceptable, are used in the evaluation of
. specific license applications.
Id.
i i
f
..Z..
_. _. _..., _ _. _.. _ -.. _ _ _..,. _ ~ _ _ _.. _ - _ -.. _. _
t
.A.-
Standard' Review Plan The NRC Staf f's Standard Review Plan ("SRP")' sets forth o
~ acceptable bases and criteria for the-review of license applications 'and for' the-conclusions to be made by the Staff for
. presention in ~ the. Safety Evaluation Report for each facility.
The SRP was originally issued in 1975 as NUREG-75/087 and was revised and' reissued in September, 1981,- as NUREG-0800.
The
' Commission has recently made clear that the SRP is not a regulation and compliance with it is not required.
The SRP acceptance criteria are intended by the Staff to provide one (but not the only) method for demonstrating compliance with the Commission's regulations.-24 24' On-March 18, 1982, the Commission published in the Federal Register a final rule requiring applicants for operating
-licenses whose applications are docketed after May 17, 1982, to include an evaluation of the differences between the application and the most recent SRP revision.
The Commission made clear in that notice that the
'SRP was simply staff guidance.
. 1.-
Types of Loads.
Section 3.9'.3 of the SRP (July 1981) 25 provides specific criteria to satisfy the relevant reqdirements of 10 CFR 50.55a
~
and GDC-1, GDC-2 and _GDC-4 regarding the structural integrity of ASME Code Class 1, 2 and 3 pressure-retaining components, component supports, and core support structures.
Specifically, Appendix A to SRP 3.9.3 provides that ASME Code Class 1, 2 and 3 component supports shall be designed to satisfy the appropriate subsections of the ASME Code in all respects.26 With respect to the consideration of specific loads in component supports, the SRP provides that the types of loadings to be taken into account in designing a component and its supports are specified in the Code.27 As is discussed below, and as demonstrated by' Applicants' expert witnesses, the ASME Code does not require that the stresses resulting from differential thermal expansion of pipe supports in a LCCA environment be considered in the design of those supports.
25 The NRC Staff has utilized the 1975 SRP in reviewing the FSAR for Comanche Peak.
However, in that the SRP does n'ot establish any licensing requirements, Applicants discuss the latest edition of the SRP in that it provides the most recent and in some instances more extensive Staff guidance on the subject.
26 SRP 3 '. 9. 3, Appendix A, Section C.(4).1.1, p. 3.9.3-14; see also SRP 3.9.3, Sections I,
II.
27 SRP Appendix A, Section B, p.
3.9.3-13.
4 n
~ 2.
Loading-Combinations.
.-With respect to the consideration of-loading combinations,
~
SRP Appendix A provides that because the ASME Code merely establishes the' types of. loads to be considered, it is the responsibility of the designer to include rules specifying how loadings (including those resulting from postulated events and
-plant and system operating conditions) are to be combined and what stress level is appropriate for use with the ' loading
- combinations.28.Section II. 3.a. of SRP 3.9.3 provides that:
~
The'com'ination of loadings (including system b
1 operating transients) considered for each component support within a system, including the designation of the appropriate service stress' lbnit'for each loading combination should' meet the criteria in Appendix A [to this SRP section]
and Regulatory Guides 1.124 and 1.130.29 The specific guidance set forth in Appendix A to SRP 3.9.3 i
regarding. consideration of loading combinations in the design of component supports, including loading combinations incorporating loads.due to system operating transients and postulated accidents l
. (e.g.,
LOCA), utilizes the four categories of limits for service i
j 28
_I_d.
29 Regulatory Guide 1.124, " Design Limits and Loading Combinations for Class 1 Linear-type Component Supports" is applicable here and is discussed below.
Regulatory Guide 1.130 concerns Class 1 plate and shell-type component supports which are not at issue here.
1
,n-4
-,,.-e~
-g
,..-,w
,...,-re,w.
,-------,,,,--,,,n..,
,,-,.,rar,,n a,.,.e
-r-v_--- -,,,, + -,
,e.
~
vv-
v g.
. i loading established'by the ASME Code,30 and supplements the 31 As discussed guidance. established 'in Regulatory Guide 1.124.
below, Regulatory. Guide 1.124 provides that stresses created in pipe-supports resulting from loads imposed on piping systems'in the event of a LOCA, superimposed on prescribed seismic'and normal operating loads, are to be considered in the design of those supports.
However, neither the applicable portions of the ASME Code nor NRC requirements and guidance require consideration-
' of the LOCA-induced stresses in linear pipe supports arising-from differential thermal expansion between the support members and the structures to'which they are attached.
B.
Regulatory Guides Two Regulatory. Guides provide guidance regarding the consideration'of LOCA-induced loads in the design of pipe
. supports.
Regulatory Guide 1.124 concerns the consideration of loading combinations for Classs'1 linear-type component supports.
Regulatory Guide, 1.26 establishes applicable standards and quality group classifications for, inter alia, Class 2 and 3 piping and supports.
Applicants discuss these provisions below 30 S RP 3. 9. 3, Definition of Terms, p.
3.9.3-19.
The categorization of loading conditions is provided for in ASME Code Subsection NA-2140.
The f.our categories applicable here are' normal, upset, emergency and faulted conditions.
See ASME Code Subsection NB-3113; see also definitions in
. Regulatory Guide 1.124, Section B.7.
i 31 S RP 3.9.3, Appendix A, Section 4.2.
i
. _ _, ~ - _.. _ _ _ _ _. -. _
..__l,_...
._,,.__.,,.m._____m__.___..
,,(_,
~
.k. '
to illustrate.the consideration given to LOCA-induced. loads in the design of linear-type. pipe supports.
While these Guides do not address the specific-question of stresses due to the restraint of thermal expansion (in that they need not be considered), they do provide information regarding the loads a-d combinations of' loads under LOCA conditions which are to be considered.
A third Regulatory Guide, Regulatory Guide 1.48, provides guidance for, inter alia, the design of ASME Code Class 1, 2 and 3 piping. 'As discussed below,-that Guide also provides for the utilization of the ASME Code for the design of' pipe supports.
Accordingly, Applicants also discuss this Regulatory Guide below.
1.
Regulatory Guide 1.124 is the principal document establishing the NRC Staff position regarding consideration of loading combinations for Class 1 linear-type componen't supports.32 The NRC Staff regulatory position, as stated in Regulatory Guide 1.124, is that ASME Code Class 1 linear-type supports should be constructed to the ru? es of Subsection NF of supplemented by the provisions of the Regulatory the Code, as 32 Loading combinations for class 2 and 3 linear supports are established in accordance with NUREG-0484, " Methodology for Combining Dynamic Loads."
SRP 3.9.3,Section IV.3.
c*:
2
=20 -
Guide. 33 The Guide'iestablishes acceptable levels of' service limits;and loading combinations associated =with normal operation,-
l
~
postulated accidents and'specified seismic: events to satisfy l
G DC-2.
The=1oadingLcombinations whichiare established in Regulatory Guide 1.124 include' simultaneous system mechanical loading,fthe dynamic system loadings associated with a faulted (i.e._, LOCA) plant. condition and _the-vibratory. motion of a Safe i :.
~-Shutdown Earthquake ("SSE").34' In addition, the Guide requires that?the" ultimate allowable stresses'in the metal-supports be 7
evaluated as a function of temperature'to account fo.r changes in i-material properties which occur in the high-temperature environment following a LOCA. event.35 Applicants' consideration I
of thes'e loading combinations is described in FSAR Tables 3.9B-lc i
and 1D.
f l
33 Regulatory Guide 1.124, Section C.
Applicants' position regarding the application of this -Regulatory Guide is set L
forth in FSAR $$ lA(N),. pp. lA(N)-63 to 67, and 1A(B) at 1A(B)-52.
This position has been accepted by the.NRC Staff.
SER $3.9.3.1.
Section lA(N) of the FSAR concerns the applicability of Regulatory Guides to the NSSS portion o'f the plant.
The supports addressed therein are component L
(e.g.,
reactor vessel, steam generator, reactor coolant pump) supports.
Piping supports are addressed in FSAR
$1A(B)'which concerns'the applicability of Regulatory Guides to the balance of the plant.
l 34-Regulatory Guide 1.124, Section C, Regulatory Position 7.
l 35 Regulatory Guide 1.124, Section C, Regulatory Position 2.
l L
- f.
- In sum,~ additional loads imposed'on piping and supports by a LOCA.are considered in-the design of those. components in combination with other severe (i.e',~SSE)~and normal loads.
However, as provided in Subsection NF of the ASME Code, and as authorized by Regulatory Guide 1.124,. stresses resulting from differential thermal ~ expansion of supports are self-limiting and need not be addressed in the design of individual supports.
2.
Regulatory Guide 1.26 establishes the quality group classifications "related to specified national standards that may
'be used to determine quality standards acceptable to the'NRC Staff for. satisfaction of General Design Criterion 1 for other
[than Class 13 safety-related~ components containing water, steam, or radioactive material" in nuclear power plants.36 The appropriate quality standards for quality group B and C piping i
are designated to be the ASME Code provisions for Class 2 and 3 piping, respectively.37 As noted previously, the portions of the Code applicable to Class 1, 2 and 3 piping (Subsection NB, NC and ND) require that supports for such piping be designed in accordance with Subsection NF of the ASME Code.38 In addition, f
36 Regulatory Guide 1.26, Section A.,
37 Id.,
Table 1.
38 See discussion, supra at pp. 12-13.
4
--i--
.--.--.r..
m-.---
.m.
-r,
-,,.--m-m ww--w,
- e ^
I SRP Section '3.2.2. confirms this interpretation where it expressly
. refers to Subsection NF for the construction of supports in-Quality Groups A,,.B and C.
SRP 3.2.2, Table 3. 2. 2-1, p.
3.2.2-8.
-Thus, the appropriateness of utilizing.the ASME Code for the-design of those supports (including the exclusion of secondary thermal loads) is further confirmed by Regulatory Guide 1.26.
3..
Regulatory Guide 1.<48.
39 Regulatory Guide 1.48 delineates' acceptable design limits and appropriate combinations of loadings associated with normal
. operation, postulated accidents, and specified seism.ic events for
~
the' design of Seismic Category 1 fluid system components.
Though not specifying design limits and loading combinations for piping-l-
supports, per,se, this Guide establishes such guidance'for ASME b
Code Class 1, 2 and 3 piping.
Specifically, the Guide delineates applicable design limits established in the ASME Code ' for 40 As noted previously, 41 the specified loading combinations.
Code itself,provides that pipe supports for piping designed in accordance with the Code shall be desigrad in accordance with 39' Regulatory Guide 1.48, Design Limits and Loading for Seismic Category I Fluid System Components" Combinations (May 1973).
Applicants' position regarding the applicability of this Guide is set forth at FSAR ((lA(N),
- p. lA(N)-28 and 1A(B), p. lA( B).-20.
40 Regulatory Guide 1.48, Sections C.1 (Class 1 piping) and C.8 (Class 2 and 3 piping).
41~
See discussion supra at 12-13.
-<w
-..--e e
,w.
.--a.--
.we-r
--.-.,w--e.,
,v-.,. -.,,,-
p
---.,,,.,,,,..,-.,-,,.r
...-.w.v.,-,,v,..y,r.r,,,.
,,,,ym,w,nww.,.,
,. ~. - -
g-v i sw.,r-~ww-ww,
D:
- Code Subsection NF.
Accordingly, this Regulatory Guide also provides for the utilization of the ASME Code in the design of supports for Class'1, 2 and 3 piping.
IV.
ASME CODE REQUIREMENTS GOVERNING CONSIDERATION OF THERMAL STRESSES A.
ASME Code Requirements While the Eoard has requested only that the parties discuss NRC regulations and guidance governing the design of pipe supports to' clarify the regulatory basis for not considering thermal stress.es in those supports under LOCA conditions, Applicants believe a brief discussion of the record in this proceeding regarding the basis for the provision in the ASME Code regarding the consideration of thermal expansion stresses would be helpful.
Accordingly, we present below a brief summary thereof.
1.
Walsh/Doyle Allegations.
Both CASE witnesse's contend that the ASME Code requires
- consideration in pipe support designs of thermal stesses induced by expansion of pipe supports under LOCA conditions.42 The thermal stresses of concern were those induced by expansion of the pipe support when heated under LOCA conditions where the support is restrained or is attached to a wall or other fixed structure on both ends.
Tr. 5233-42.
42 CASE Exhibit 659 at 2; 659B; Tr. 3677.
v-
- ~ ~ -
2.
Applicable Code Provisions.
Article :NF-3000 of 'the' ASME Code ~ contains both general requirements-(NF-3100), and specific' rules that vary depending upon the type of support.
The general requirements,.NF-3100, merely identify loads that should be included in the design specifications for the diferent types of supports.
In order to
-determine Which loads are to be'used for any specific situation, the designer must consider the specific rules depending on the Class (1, 2,
or 3), type (plate and shell or linear) and loading condition (normal, upset, emergency and faulted).
F_or Class 1, 2
or:3 linear supports, the Code (NF-3231.1) does not require thermal stresses to be considered for any loading condition.43 Further, thermal stresses are defined as secondary stresses by the ASME Code.
Section NF-3213.8 of the Code provides that secondary stress is a normal stress or a shear stress developed by the constraint of adjacent material or by self-constraint of the component.
The basic characteristic of a secondary stress is that it is self-limiting. The self-limiting characteristic arises l
because of ductile displacement in the beam upon expansion Which l.
relieves the thermal stress.44 l
43 Applicants' Exhibit 142 at 14-15; Tr. 5230-32.
l 44 Applicants' Exhibit 142 at 15; Tr 5236-37.
\\
I I
(
i
.. _. _ ~. _ _ _ _ _ _ _ _.., - _ _ _
'e 1 In sum,- the ASME Code. clearly excludes consideration of -
thermal stress in the design offlinear-type pipe supports.
While this alone should be sufficient to find that the design of the supports for Comanche Peak is adequate, Applicants' witnesses-also provided a detailed analysis of the self-relieving characteristics of thermal stresses. ' This analys'is is also discussed below.
t B.
Analysis of LOCA Temperature Effects To demonstrate the technical' validity of the position in the ASME. Code regarding consideration of thermal stresses in linear-type pipe supports, Applicants performed an analysis of the self-limiting characeristics of thermal stresses with respect to
- th'e slippage of support attachments or deformation of welds at anchorages.
This analysis demonstrated that the movement of the support anchors under thermally induced stress relieves that i
stress.
The analysis of LOCA temperature effects on the anchors is based on the use of test data results of load versus
- displacement characeristics of various types of anchors (Hilti Bolts, Richmond Anchors,45 and Nelson Studs).
The analyses 45-As noted previously (see note 12, supra) the NRC Staff concurred in this assessment but requested that additional testing be performed to confirm the allowable for one size of Richmond Anchors.
This additional testing was completed successfully.
e wvww.
y vv---
r e-m--
-et-7-&re----9~m,-wr
-e--
- =*
-sw-'-v-
-r 7+
~-+--w-
- - - = - - * -
e performed in Applicants' Exhibit 142D are conservative because they were performed on the most extreme conditions which exist at Comanche Peak.46, The analysis performed by Applicants comports with sound engineering principles and affords more realistic results of thermal stresses than if the anchors are ' assumed to be " rigid. "
In the case of thermal stresses, it was demonstated that anchors which would ordinarily be considered rigid have, in fact, enough
" flexibility" to relieve virtually all thermal stress.47 In response to the Board's questions, Applicant.s' witnesses also provided~further explanation of these specific stress-
. relieving mechanisms.
Specifically, Applicants' witnesses testified that 'in the case of a support beam which spans. between two structures, such as floor-to-ceiling and wall-to-wall, the displacement Which relieves the thermal stress.could arise either from slight displacement of the structures upon expans' ion of the beam or by local yielding of the structual member.
The latter yielding results in minute plastic deformation of the support 46 -
Applicants' Exhibits 142 at 22 and 142D; Tr. 5239-40, 5250.
47 Applicants' Exhibit 142 at 23-24.
~
O,
which relieves the-thermal. stress.
The relief of thermal stresses induced.in a support with a beam mounted on a wall.by a series of bolts occurs by a displacement of the bolts.48 In sun, the recordL in this proceeding reflects that the ASME Code permits the exclusion of thermal stresses from the analysis of Class 1, 2 and 3 linear-type -pipe supports.
Further, the i
record also. reflects that such provisions of the Code have been demonstrated by analysis and sound engineering principles and judgment to be technically correct.
Thus, the exclusion of those stresses from 'the design of pipe supports at Comanche Peak does j
not raise any valid design question or present any adverse implic~ations for the safe operation of the facility or its ab'ility to withstand the effects of postulated accidents.
V.
CONCLUSION As demonstrated above, NRC regulations and Staff guidance implementing those regulations clearly provide for th'e 1
utilization-of the standards established by the ASME Code for
-determining the types of stresses to be considered in the design of pipe supports.
In turn, and as demonstrated in the record of 4
this proceeding, the Code provides that the thermal stresses induced in linear-type supports are self-limiting, and therefore need not be considered in the design of individual supports.
i '
48 Applicants' Exhibit 142D; Tr. 5239-56.
1 4
-~
--. m
..-----y.
,_e,.m.-..,a w--
.+.,-,-m.r-
W o.
28 -
. Accordingly, Applicants submit that upon conclusion of the testimony of'the NRC Staff on these-matters, the record should be closed.
Respect ul submitted,
,/
i Nichola S
Reynolds I
L 9
William A.
H6rin' DEBEVOISE & LIBERMAN 1200 Seventeenth Street, N.W.
Washington, D.C.
20036 (202) 857-9817-Counsel for Applicants April 21, 1983-
'r r~
~-s--
--~
r-
r o
UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THN ATOMIC SAFETY AND LICENSING }DARD In the Matter of
)
)
TEXAS UTILITIES GENERATING
)
Docket Nos. 50-445 and COMPANY, el al.
)
50-446
)-
(Comanche Peak Steam Electric
)
(Application for Station, Units 1 and 2)
)
Operating Licenses)
CERTIFICATE OF SERVICE I hereby certify that copies of the foregving " Applicants' Brief Regarding Consideration Of Thermal Stresses In Design Of Pipe Supports" and " Applicants' Brief On The Effect On This Proceeding Of The Recommended Decision Of The Department Of Labor's ALJ In 'Atchison v. Brown & Root'," in the above-captioned matter were served upon the following persons by express delivery
(*), deposit in the United States mail, first class postage prepaid, or by ' hand delivery. (**)
this 21st day of April,.1983:
- Peter B.
Bloch, Esq.
Chairman, Atomic Safety and Chairman, Atomic Safety and Licensing Board Panel Licensing Board U.S. Nuclear Regulatory U.S. Nuclear Regulatory Commission Commission Washington, D.C.
20555 Washington, D.C.
20555
- Lucinda Minton, Esq.
- Dr. Walter H. Jordan Atomic Safety & Licensing Member, Atomic Safety and Board Licensing Board U.S. Nuclear Regulatory 881 W.
Outer Drive Commission Oak Ridge, Tennessee 37830 Washington, D.C.
20555
- Dr. Kenneth A. McCollom
- Marjorie Ulman Rothschild, Esq.
Dean, Division of Engineering Office of the Executive Architecture and Technology Legal Director Oklahoma State University U.S.
Nuclear Regulatory Stillwater, Oklahoma 74074 Commission Washington, D.C.
20555
I'
+
. Mr. John Collins Chairman, Atomic Safety and Regional Administrator, Licensing Appeal Panel Region IV U.S.
Nuclear. Regulatory U.S. Nuclear Regulatory Commission Commission Washington, D.C.
20555
.611 Ryan. Plaza Drive Suite 1000 Mr. Scott W.
Stucky Arlington, Texas 76011 Docketing & Service Branch U.S. Nuclear Regulatory
- David J.
Preister, Esq.
. Commission Assistant Attorney General Washington, D.C.
20555 Environmental Protection Division
- Mrs. Juanita Ellis P.O. Box 12548 President, CASE Capitol Station 1426 South Polk Street Austin, Texas 78711 Dallas, Texas 75224 LW William;A. Horin cc:
Homer C.
Schmidt Spencer C.
Relyea, Esq.
t l
l i
l l
~
e I