r t

e GPU Nuclear Corporation L

U Nuclear

= ; % % s4 201-316-7000 TELEX 136-482 Writers Direct Dial Number.

June 6, 1994 C321-94-2080 5000-94-0026 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555 Gentlemen:

Subject:

Oyster Creek Nuclear Generation Station (0CNGS)

Operating License No. DPR-16 Docket 50-219 Additional Information Requested by the NRC Staff Re:

Generic Letter 92-01, Revision 1, " Reactor Vessel Structural Integrity" On April 19, 1994, GPU Nuclear responded to your letter dated March 30, 1994 concerning Generic Letter 92-01, Revision 1, " Reactor Vessel Structural Integrity" issues.

Subsequently, Mr. A. Dromerick, Sr. Projector Manager, NRR-NRC requested GPU Nuclear to complete the " Equivalent Margin Analysis Plant Applicability Verification Form" (Appendix B, NED0-32205) with the plant specific data.

Enclosed is the completed verification form.

If you have any questions concerning the data provided, please contact Mr. M. W. Laggart, Manager, Corporate Licensing at (201) 316-7968.

Sincerely, R. W. Keaten Vice President and Director Technical Functions

/crb cc: Administrator Region I NRC Oyster Creek Project Manager Senior Resident Inspector l

94061 0123 940606 h)

PDR ADOCK 05000219 Q

PDR 1

v i

GPU Nuclear Corporation is a subsidiary of General Pubke Utihties Corporation

1

)

NEDO-32205-A j

EQUIVALENT MARGIN ANALYSIS PLANT APPLICABILITY VERIFICATION FORM

)

I FOR oyster creek BWR/2-6 WELD I

Surveillance Weld USE:

%Cu =

0.28 Capsule Fluence = 7.46 x 1017 (n/c,,2 )

NA Measured % Decrease (Charpy Curves)

R.G. 1.99 Predicted % Decrease =

24%

(R.G. 1.99, Figure 2)

  • Based on one surveillance data point.

Limitina Beltline Weld USE:

%Cu =

0.3s 2

32 EFPY Fluence = 2.36 x to (n/cm )

R.G. 1.99 Predicted % Decrease =

34 (R.G. 1.99, Figure 2)

NA**'

(R.G. 1.99, Position 2.2)

Adjusted % Decrease =

    • Oyster Creek has only one credible surveillance data. Therefore, RG'1.99 position 2.2 is not applicable.

l 34 % 134%, so vessel welds are bounded by equivalent margin analysis

)

i

]

^~

NEDO-32205-A EQUIVALENT MARGIN ANALYSIS PLANT APPLICA51LITY VERIFICATION FORM FOR oyster creek BWR/2 PLATE Surveillance Plate USE.

1

%Cu -

0.17 Capsule Fluence - 7.46 X 10 (n/cm )

Measured % Decrease -

7 (Charpy Curves) i R.G. 1.99 Predicted % Decrease -

14 (R.G. 1.99, Figure 2)

  • Based on one surveillance data point.

limitina Beltline Plate USE:

%Cu =

0.21 l

2 32 EFPY Fluence - 2.36 X 10 (n/cm ).

R.G. 1.99 Predicted % Decrease =

21.5 (R.G.-1.99, Figure 2) l I

Adjusted % Decrease -

NA (R.G. 1.99, Position 2.2)

    • Oyster Creek has only one credible surveillance data. Therefore, RG 1.99 position 2.2 is not applicable.

21.5% $ 26%, so vessel plates are bounded by equivalent margin analysis j

1

--