VIHOINIA I3LECTRIC AND power COMPANY RIciIxoxn,VIHOINIA 20061 w.L.srnw ar x[E."aT".'""o,
March 23, 1983 Mr. Harold R. Denton, Director Serial No. 709C Office of Nuclear Reactor Regulation PSE/TLG/brh/0366C Attn: Mr. Robert A. Clark, Chief Docket Nos. 50-338 Operating Reactors Branch No. 3 50-339 Division of Licensing License Nos. NPF-4 U. S. Nuclear Regulatory Commission NPF-7 Washington, D.C. 20555 Gentlemen:
NUREG-0612 - CONTROL OF HEAVY LOADS NORTH ANNA P0HER STATION UNITS 1 AND 2 In our letter dated March 1, 1983, (Serial Number 7098), Vepco's response to TER 2.1.8 Crane Design (Guideline 7, NUREG-0612, Sec. 5.1.1(7)), stated that the remaining four items all meet the requirements of CMAA-70 and that a report would be forwarded to the NRC as a final response to TER 2.1.8.
Enclosed, please find a copy of " Comparison Between CMAA-70 and E0CI-61" Report prepared for Vepco by Bechtel Associates Professional Corporation.
This report addresses the 14 requirements of CMAA-70 and will serve as Vepco's Final Response to TER 2.1.8.
Very truly yogy,
//V H. L. Stewart Enclosure cc:Mr. James P. O'Reilly Regional Administrator Region II Oko!$oo$$g PDR